Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
Lumped Components, Microminiature Bandpass — IB Series
USA EUROPEPhone: 410-749-2424 Phone: +44-(0)-1908-547920FAX: 410-749-5725 FAX: +44-(0)-1908-695284Email: [email protected] Email: [email protected]
Filtering Solutions for Your Global Market
Order On-Line @ www.klmicrowave.com TM
30-10000* 3-70 1.5:1 1 50 2-10
◆ Specifications:
Frequency(MHz)
3 dB %BW
VSWR Impedance(Ohms)
No. ofSections Shock Vibration Temperature
RelativeHumidity
20 G’s, 1/2 Sine,
11 Ms
10 G’s, 10 Hz-
2000 Hz-55 to +85 °C 0-95%
AveragePower (Watts)
◆ Insertion Loss:The insertion loss at the center frequency of the filter isdetermined by the equation:
Loss = (Loss Constant) (No. of Sections + 0.5) +.3% 3 dB BW
Where the loss constant is frequency dependent and maybe found from the table to the side.
Example:
At 500 MHz, 5 sections, 60 MHz BW
Loss = (4.4)x(5.5) +0.3 = 2.3 dB12
◆ Loss Constant:
CenterFrequency
(MHz)
10-159160-199200-299300-399400-499500-599600-699700-799800-899900-999
1000-6000
8.87.86.85.74.94.44.03.73.53.253.0
Constant
◆ Features:
• Small, Compact Package
• Covers the 30 MHz to 10 GHz Frequency Range
• Standard 3 dB BW Available from 3-15%
• 3 dB BW also Available up to 70% (Contact Factory)
• Designs Available in 2-10 Sections
• 0.05 dB Chebyshev Design
• Ruggedized Package
• Custom Designs Available
* Certain combinations of frequency and bandwidth are not practical. Contact Factory with your requirements.All packages can be provided to full MIL-SPEC environmental requirements.
USA EUROPEPhone: 410-749-2424 Phone: +44-(0)-1908-547920FAX: 410-749-5725 FAX: +44-(0)-1908-695284Email: [email protected] Email: [email protected]
Filtering Solutions for Your Global Market
Order On-Line @ www.klmicrowave.comTM
Lumped Components, Microminiature Bandpass — IB Series
◆ Attenuation:
These curves show the attenuationnormalized to the 3 dB bandwidth for filterswith 2-8 sections. The following formula isused: 3 dB bandwidths from centerfrequency =
Reject Frequency - Center Frequency3 dB BW
Example:
Center Frequency = 500 MHz3 dB Bandwidth = 60 MHzNumber of Sections = 5Find the attenuation at 400 and 600 MHz bysubstituting in the formula 3 dB bandwidthsfrom center frequency = 400-500 = -1.67 BW’s
60and 3 dB bandwidths from centerfrequency = 600-500 = +1.67 BW’s
60
From the 7 to 15 % curve we find theattenuation in dB for a 5-section response -1.67 BW’s from center frequency yields60 dB, and +1.67 BW’s from centerfrequency yields 34 dB.
◆ For Bandwidths 3 to 7%
◆ For Bandwidths 7 to 15%
◆ Package Style 3:
Lumped Components, Microminiature Bandpass — IB Series
USA EUROPEPhone: 410-749-2424 Phone: +44-(0)-1908-547920FAX: 410-749-5725 FAX: +44-(0)-1908-695284Email: [email protected] Email: [email protected]
Filtering Solutions for Your Global Market
Order On-Line @ www.klmicrowave.com TM
◆ Connectors:Connector Code
SMA Female OSMA Male OP
PC Pins P
◆ To Order:5 I B 30 — 500 / T 60- P / P12 3 4 5 6 7 8 9
Code Description1 Number of Sections2 Series (I - Microminiature)3 B - Bandpass4 Package Designator - Style 35 Center Frequency (MHz)6 Supplemental Codes (See Page 13) 7 Bandwidth (MHz)8 Input Connector9 Output Connector
Section L-Inches L-mm2-3 .75 19.054-5 1.0 25.406-7 1.50 38.108-9 1.75 44.4510 2.0 50.80
◆ Package Style 4: