Welcome to Lumenrail® by Wagner Architectural. We believe you will find these systems to be exceptional, with brilliant lighting performance and beautiful aesthetics.
Wagner is well known by metal fabricators for our dedication to high quality, American-made architectural products; the Lumenrail® line integrates more than 150 years of metalworking history with state-of-the-art light fixtures and engineering methods to deliver to owners an unparalleled installation of handrail and custom illuminated metalwork.
The products herein are just a sampling of the options offered by Wagner. Starting with innovative standard products, we can help you craft a bold illuminated handrail. Our extensive fabrication and metals-finishing capabilities allow us to help you create striking custom lighting fixtures. From collaborative concept reviews, to full 3-D modeling of the project, through manufacturing and delivery, we will exceed your expectations.
Please contact us to discuss your next illuminated handrail or custom lighting project.
Bob Wagner
2
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
LUMENRAIL®
APPLICATION
• ETL and cETL listed LED illuminated railing system delivering pathway and wall illumination for indoor and outdoor use.
• Designed to satisfy ANSI, ADA, ABA and IBC codes/standards when properly specified and installed.
• May be used for egress lighting and emergency lighting with backup system.
• All systems require remote drivers.
CONSTRUCTION
• Guardrail or Handrail – Curved or Straight• Wall or Post Mount • Posts and brackets are typically spaced no further than 5' on center
to meet structural load requirements • Post mounted railings have several infill panel options available
including cable, glass and Archimesh™ woven wire.
Thomas Street Bridge Designed by: Hewitt
3
Milwaukee Art MuseumDesigned by: HGA Architects and Engineers
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
LUMENRAIL® LINEAR
LUMENRAIL® TECHNICAL SPECIFICATIONS
CCT: 2700° K, 3000° K, 3500° K, 4000° K, 5000° K, Red, Green, Blue and Wildlife AmberCRI: 84+Power Consumption Standard Output: 2W/Ft Medium Output: 4W/Ft High Output: 6W/FtLens Finish: Matte and Transparent Distribution: Symmetric - 70° or 120° Asymmetric - Max Candle Power 45° above nadirVoltage: 24 VDCDriver: Class 2, 100 Watt, 24 VDC driver, 115-277 VAC or
347 VAC inputListing: ETL and cETL listed for wet locationDimmable: PWMBattery Backup: Compatible with sine wave inverters
4
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
ELECTRICALWALL MOUNT WIRING DIAGRAM
LED Light StripDouble End Feed Termination
Light Backing Pad 22 AWG, 300 VoltTTFN RatedPower Cord
Wire Nut Connections Within Wireway
Slotted Tube InsertAs Required
Light Mounting Clip
Secondary Feed RoutedThrough Stainless Bracket
Driver with Enclosure
Transition Sleeve
120 - 277 Volt Input(Conduit Entry)
120 - 277 Volt Input(Conduit Entry)
POST MOUNT WIRING DIAGRAM
LED Light Strip
Double End Feed Termination
Light Backing Pad 18 AWG, 600 VoltTTFN RatedPower Cord
Wire Nut Connections Within Wireway
Slotted Tube InsertAs Required
Light Mounting Clip
Driver with Enclosure
Transition Sleeve
120 - 277 Volt Input(Conduit Entry)
120 - 277 Volt Input(Conduit Entry)Secondary Feed Routed
Through Stainless Post
All electrical connections to be made by a qualified electrician in accordance with all national, state and local electrical codes.
Remote Mounting Distance Chart
24 VDC100W DRIVER
MAXIMUM DISTANCE FROM DRIVER TO FIRST LED
WIRE SIZE 10AWG
12AWG
14AWG
16AWG
18AWG
DISTANCE 120’ 71’ 46’ 29’ 18’
5
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
4000K Light Foot Candle Chart
LIGHT DISTRIBUTION
Factors for othercolor temperatures:
3000° K 98%3500° K 99%5000° K 120%
6
0 1’ 2’ 3’ 4’ 5’ 6’ 7’7’ 6’ 5’ 4’ 3’ 2’ 1’Light Option:2W/Ft Matte2W/Ft Transparent
4W/Ft Matte4W/Ft Transparent
6W/Ft Matte6W/Ft Transparent
0.4
0.80.5
1.40.7 1.0 1.1 2.1 4.3 20.5 62.4 62.469.6
2.1 3.2 5.1 8.7 8.74.3 1.1 1.0 0.72.1
5.1 3.2 2.1 1.424.8 24.820.5
49.8 49.854.7
0.72 1.9 3.3 12.6 40.8 40.8 12.6 3.3 1.9 0.7 0.51.244.21.21.9 3.0 4.9 13.6 13.6 4.9 3.0 0.81.9 1.228.0 28.030.41.2
0.40.2 0.4 0.7 1.4 1.4 0.7 0.4 0.221.5 21.523.87.3 7.3
1.0 2.0 2.0 1.0 0.5 0.44.0 4.07.5 12 13 12.9 7.5
34" High Rail
120°3000° K4000° K
131 235 336147 268 383Matte Matte MatteTransparent Transparent Transparent
132 247 361152 284 413
2 W/Ft 4 W/Ft 6 W/Ft
Beam Angle Output
270°180°
70°
270°180°
3000° K4000° K
131 235 336147 268 383Matte Matte MatteTransparent Transparent Transparent
132 247 361152 284 413
2 W/Ft 4 W/Ft 6 W/Ft
0°
3000° K4000° K
126 206 290 130 237 290Matte Matte MatteTransparent Transparent Transparent
115 232 301129 242 343
2 W/Ft 4 W/Ft 6 W/Ft45° above nadir
270°180°
Lumens/Foot - Consult factory for other configurations
Symmetric
Symmetric
Asymmetric
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM7
TECHNICALELECTRICAL
Lumenrail® operates on 24V DC power supplied by a Class 2, 100 Watt driver housed in a NEMA 3R enclosure. Up to 3 drivers may be daisy chained together for longer railing runs.
Lumenrail LEDs consume as few as 1.8 watts per foot where up to 40' of lights may be powered off each individual driver. The driver must be remotely located from the rail.
Lumenrail is dimmable using pulse width modulation. Please consult your Lumenrail representative or Wagner for PWM dimming module suggestions and other information.
INFILL OPTIONS
When used in a guard rail application, the guard must meet the requirements of the building code. Typically this would require a minimum height of 42" — for commercial applications — with no openings large enough to permit the passage of a 4" sphere. To meet this requirement, an infill of some type will be required. Lumenrail is available with several choices of infill, including: Cable, Glass and Archimesh™ woven wire.
MOUNTING
SURFACE MOUNT
1"
Anchor Plate With Cover Flange
Concrete
41 /2" 13/16
"
Concrete
EMBEDDED
Cover FlangeWith or Without
Set Screw
Rockite®
or Kwixset ®
½“ or ¾“conduit
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
CUSTOM ILLUMINATED PROJECTS
Signage Down Lighting
18" Tall Adjustable Pathway Lighting
Wall Wash Lighting
Wagner has extensive metal working capa-bilities and decades of manufacturing experi-ence. We are able to successfully combine our existing components in new ways to create custom lighting solutions beyond illuminated hand rails.
8
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
CABLE RAILWagner has more than 10 years of history supplying cable rails.
• Created to address the deficiencies encountered in using standard tensioning mechanisms for cable barrier railings
• All retainers feature smooth lines and soft edges• Fittings are engineered to blend with the rail• Factory or field swaged fittings hide crimps• Spec-grade 316 alloy cable resists staining and provides high quality finish and appearance
9
Hank Aaron State Trail Designed by: HGA Architects and Engineers
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
CABLE RAIL
Marquette UniversityDesigned by: Opus Design Build
CABLE RAIL
10
Invisiware® Receiver
Invisiware Swaging Stud
Pull-Lock™ Swageless Fitting
Push-Lock Swageless Stud with Invisiware
Push-Lock™ Fitting
Clip-On Stop
Adjust-A-Body with Hanger Bolt for Straight Runs
Adjust-A-Body with Threaded Bolt
Adjust-A-Jaw® with Threaded Tab
Adjust-A-Jaw with Lag Eye
Fixed Jaw with Lag Eye
Adjust-A-Body™ with Concrete Bolt Tensioner
Inside to Inside
Outside to Inside
Outside to Outside
Invisiware Radius Ferrule
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM11
ARCHITECTURAL MESH INFILL PANELS• Framed woven wire panels for use in architectural railing applications• All panels are Type 304 Stainless Steel• Designed for use within Wagner’s slotted Rail Sections• Archimesh™ Panels by Banker Wire• Custom weave options are available
STAINLESS BWM13Z-145
Open Area: 64.5%Weight: 1.75 lbs/sq ftOpening Limitation: .471"
Overall Thickness: .365"Aspect Ratio: 7.01:1
STAINLESS BWL-62
Open Area: 70.1%Weight: 1.70 lbs/sq ftOpening Limitation: .838"
Overall Thickness: .320"Aspect Ratio: 1.00:1
STAINLESS BWP-278
Open Area: 81.7%Weight: 1.20 lbs/sq ftOpening Limitation: 1.810"
Overall Thickness: .380"Aspect Ratio: 1.00:1
LARGE WEAVE Images are shown at approximately 50% of full size.
Montgomery CollegeDesigned by: Slater Associates
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM 12
Wagner’s Legato™ Railing Collection combines simplicity with style. It’s an easy-to-install, durable line that comes in a range of high-quality, attractive design options to customize your look..
ARCHITECTURAL GLASS SYSTEMS
PanelGrip® is a dry glazed glass railing system designed to reduce installation costs by up to 80% while satisfying all building code requirements for glass railing.
Shoe Mounted Glass System
glass railing system
The LegatoTM Railing Options accommodate guard, stair or ramp applications for a range of glass thicknesses. The glass infill is secured via glass mounting hardware. These options are available in an assortment of post shapes and glass mounting designs, offering surface, embedded and fascia post mounting options with mid, end and corner post configurations.
Round Square Flat
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
4" - 61/4" Perimeter
21/4" Maximum
21 /4"
Maximum
BUILDING CODESAll references in this section are taken from current versions of the model codes — International Building Code (IBC), the National Fire Protection Association (NFPA) Life Safety Code, as well as standards from the American National Standards Institute (ANSI), the Americans With Disabilities Act (ADA) and Architectural Barriers Act (ABA) Standards for Acces-sible Design.
Local jurisdictions generally use these codes and standards to create their own. Always confirm with your local Authority Having Jurisdiction (AHJ) prior to using or specifying any railing products.
HANDRAIL AND GUARDHandrails are in place to provide guidance while the purpose of a guard is to prevent accidental falls.
Guards are generally required for ramps, stairs or landings with a drop greater than 30".
The IBC requires a guard to be a minimum of 42" above the walking surface. The International Residential Code (IRC) minimum height requirement is 36".
Handrails are located between 34" and 38" above stair nosings and have dimensional limitations for graspability. Under the IBC, if a 42" guard is called for on a stair or ramp, it will also require a handrail at the appropriate height.
Handrail also must meet dimensional requirements for graspability as shown in the image to the right. A guard top rail, that is not used as a handrail, would not have a graspability size limitation.
Guards also have opening limitations to consider. Both the IRC and the IBC state that no opening be large enough to allow a 4" sphere to pass.
While a handrail may need to be installed on stairs less than 30" high, it does not have to meet the opening limitations required of a guard.
LOAD REQUIREMENTSIn addition to dimensional and infill requirements, handrails and guards are required to withstand a minimum structural load of 200 lbs concentrated or 50 lbs/ft uniform at the top of the guard or handrail. Infills are required to meet a 50lb/sq ft load.
ACCESSIBILITY GUIDELINES AND STANDARDSThere are three primary references that have been used throughout the country in relation to accessibility: ICC/ANSI A117.1, Accessible and Usable Buildings and Facilities,” and the Americans with Disabilities Act (ADA) and Architectural Barriers Act (ABA) Standards for Accessible Design” (SAD).
Many states have their own accessibility standards based on the 2010 ADASAD. While they are for the most part in harmony with the federal standard, some variances exist. Again, always confirm with your local AHJ to avoid costly delays or changes.
HANDRAIL DIMENSIONSCurrent codes are now in harmony regarding most handrail dimensions and clearance requirements.
Handrail gripping surfaces with a circular cross section must be between 11/4" minimum and 2" maximum.
Non-circular handrail is limited to a maximum cross section of 21/4" with a perimeter dimension between 4" and 61/4".
1.25" 3.92" 0 11/2"
13/8"
11/4"
1"
1"
-1/8"
-1/4"
-1/2"
-1/2"
4.71"
5.21"
5.97"
6.28"
1.50"
1.66"
1.90"
2.00"
RailingDiameter
Subtract FromUnderside of
Railing
Clearance from Underside of
RailingPerimeter
Handrail is also required to be free of obstructions. If mounted to the top of a post, the bottoms of the handrail may not be obstructed for more than 20% of their length.
If mounted to a wall or the side of a post, the handrail must be a 11/2" minimum clearance.
NOTE: If your handrail is subject to the requirements of NFPA 101 - Life Safety Code, you will need to provide a minimum clearance of 21/4". Also note that the California Accessibility Standards are still using the 1990 ADAAG requirement that handrail must be 11/2" — absolute — from the wall. Always confirm requirements with your local AHJ.
Where provided, horizontal projections (i.e. bracket arms) shall occur 11/2" minimum below the bottom of the handrail gripping surface. The distance between horizontal projections and the bottom of the gripping surface shall be permitted to be reduced by 1/8" for each 1/2" of additional handrail perimeter dimension that exceeds 4". Use this table for reference.
13
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
12" min.12" min. 1 tread
width
12" min.
1 treadwidth
12" min.
1 treadwidth
12" min.
BUILDING CODESHANDRAIL EXTENSION REQUIREMENTSHandrail extension requirements have changed in the more recent versions of the various codes and standards. You should confirm whether your local AHJ has updated to the current versions of these requirements.
At the top of a stair, handrail must extend horizontally above the landing for 12" minimum beginning directly above the first riser nosing. At the bottom of a stair, handrail must extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the last stair nosing.
For a ramp, a 12" horizontal extension is required at both the top and bottom landings.
Some local AHJs are still requiring a horizontal extension at the bottom of a stair or have longer extension requirements.
Extensions must also return to a wall, guard, or the landing surface; or shall continue to the handrail of an adjacent stair flight.
Return To Itself
Wall Mounted Ramp Rail Return To Wall
Return To Walking Surface
14
42" or greater
34"-38" inches tall
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
Lumenrail® Linear - Symmetric
Optional Accessories
MADE INTHE USA
Part # Builder
LULS -Fixture Type Color Temp Length
Lumenrail Linear 6 = 7.64"12 = 13.51"18 = 19.39"24 = 25.33"30 = 31.23"36 = 37.14"42 = 43.07"
Fixture Wattage Lens Option
TS = Transparent Symmetric
MS = Matte Symmetric
Beam Angle
48 = 48.95"54 = 54.89"60 = 60.83"66 = 67.20”72 = 73.20”78 = 79.20”84 = 85.20”
PhotometricsLumens/Foot - Using 120° Beam Angle
70° 120°3000° K4000° K
131 235 336147 268 383Matte Matte MatteTransparent Transparent Transparent
132 247 361152 284 413
2 W/Ft 4 W/Ft 6 W/Ft
Contact factory for other configurations
Nominal - Assembled
20 = 1.85 W/FT40 = 3.57 W/FT60 = 5.45 W/FT
Electrical Specifications
*IES Full Cutoff classification when installed in Wagner handrail
Input Voltage Listing Enclosure
Operating Temp Driver Location
Efficiency CRI Warranty
24 VDC
-40 to 120° F
Up to 82 lm/W
ETL listed, UL 1598/CSA 22.2; CE
Must use class 2 driver
Up to 88 (95 avail. upon request)
Minimum NEMA 3R required
Wet location rated
5 year warranty
Dimming PWM
270°180°
Class 2 Driver Options Enclosure
LUDRIVER100W(Non Dimming)
Input voltage = 120-227 VACOutput voltage = 24 VDC5 year warranty
LUNEMA4X NEMA 4X ENCLOSURE 3” X 3”
LUDRIVERDM96WSYL(DIMMING 0-10V) LUENCLOSURE
NEMA 3R ENCLOSURE4” X 4” X 18”
CONSULT FACTORY FOR OTHER OPTIONS
Project Name:
Rep Agency:
Approx. Linear FT.
27K = 2700° K30K = 3000° K35K = 3500° K40K = 4000° K50K = 5000° K AMB = Amber RED = Red BLU = Blue GRN = Green
Sample: LULS30K40120TS18
Mounting Distance Chart
24 VDC100W DRIVER MAXIMUM DISTANCE FROM DRIVER TO FIRST LED
WIRE SIZE 10AWG
12AWG
14AWG
16AWG
18AWG
DISTANCE 120’ 71’ 46’ 29’ 18’
Remote Guidelines
*All electrical connections to be made by a qualified electrician in accordance with all national, state and local electrical codes.
15
70 = 70° Spread120 = 120° Spread
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
Project Name:
Rep Agency:
Optional Accessories
MADE INTHE USA
Photometrics
270°180°
Lumens/Foot0°
Part # Builder
LULS -Fixture Type Color Temp LengthFixture Wattage Lens Option
20 = 1.85 W/FT40 = 3.57 W/FT60 = 5.45 W/FT
TA = Transparent Asymmetric
MA = Matte Asymmetric
Beam Angle
70 = 70° Spread 6 = 7.64"12 = 13.51"18 = 19.39"24 = 25.33"30 = 31.23"36 = 37.14"42 = 43.07"
48 = 48.95"54 = 54.89"60 = 60.83"66 = 67.20”72 = 73.20”78 = 79.20”84 = 85.20”
Nominal - Assembled
Lumenrail® Linear - Asymmetric
27K = 2700° K30K = 3000° K35K = 3500° K40K = 4000° K50K = 5000° K AMB = Amber RED = Red BLU = Blue GRN = Green
Electrical Specifications
*IES Full Cutoff classification when installed in Wagner handrail
Input Voltage Listing Enclosure
Operating Temp Driver Location
Efficiency CRI Warranty
24 VDC
-40 to 120° F
Up to 77 lm/W
ETL listed, UL 1598/CSA 22.2; CE
Must use class 2 driver
Up to 88 (95 avail. upon request)
Minimum NEMA 3R required
Wet location rated
5 year warranty
Dimming PWM
3000° K4000° K
126 206 290 130 237 290Matte Matte MatteTransparent Transparent Transparent
115 232 301129 242 343
2 W/Ft 4 W/Ft 6 W/Ft
Approx. Linear FT.
*All electrical connections to be made by a qualified electrician in accordance with all national, state and local electrical codes.
Lumenrail Linear
Sample: LULS40K6070TA24
Class 2 Driver Options Enclosure
LUDRIVER100W(Non Dimming)
Input voltage = 120-227 VACOutput voltage = 24 VDC5 year warranty
LUNEMA4X NEMA 4X ENCLOSURE 3” X 3”
LUDRIVERDM96WSYL(DIMMING 0-10V) LUENCLOSURE
NEMA 3R ENCLOSURE4” X 4” X 18”
CONSULT FACTORY FOR OTHER OPTIONS
Mounting Distance Chart
24 VDC100W DRIVER MAXIMUM DISTANCE FROM DRIVER TO FIRST LED
WIRE SIZE 10AWG
12AWG
14AWG
16AWG
18AWG
DISTANCE 120’ 71’ 46’ 29’ 18’
Remote Guidelines
16
70
@ 45° above nadir
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
LUMENRAIL® QUOTATION REQUEST FORMCompletion of this form, and providing us with highlighted drawings, has proven to greatly reduce our turn-around time
on quotation requests. Your assistance is greatly appreciated.
Request Date:
Company Name:
Email:
Project Name:
Status: Budget Hard Bid
Specifier:
Quotation Due Date:
Contact Name:
Phone:
Project Location:
Date Req’d On Site:
Specifier Contact Name:
Approximate Linear footage of handrail types:
ILLUMINATED - Wall Mount: Post Mount:
NON ILLUMINATED - Wall Mount: Post Mount:
No handrail required, lighting component quote only.
Luminaire specification (Color, Control, Wattage, Distribution and Lens Finish)
Select one CCT:
2700°K 3000°K 3500°K 4000°K 5000°K Amber (590-592nM) Blue Green Red
Select dimming: Yes No
2 Watts/FT 4 Watts/FT 6 Watts/FT
Select one distribution combination:
70° Symmetric 120° Symmetric Asymmetric (45° above nadir)
Select one wattage:
Select one lens finsih:
Matte Transparent
Handrail material specification (Outsite Diameter, Metal Alloy, Finish & Length)
Select one size:1.50” OD 1.66” OD 1.90” OD
Select one metal finish:
304 Stainless Steel 316 Stainless Steel 6063 Aluminum
Select one metal:
#4 Satin, Circumferential brushed SS #4 Satin, longitudinal brushed SS #7 Brite, polished SS
Clear anodized (Silver) AL Bronze anodized (Duranodic) AL
Auxiliary component detail:Standard 100 Watt, Non-Dimming Driver & NEMA 3R Enclosures included on quote. Quantity based on design and/or watts/foot.
Installation Notes:All electrical connections to be made by a qualified electrical contractor in accordance with national, state and local codes.All railings need to be installed by a qualified handrail installer.
17
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
STAIR AND RAMP MEASURING SHEET
1) Make a complete sketch of the stairs withcorrect number of tread and risers.
2) Measure the nose to nose and overall rise of the stairs. These are the most critical dimensions for Wagner. 3) Measure all of the other dimensions if possible, including individual tread depth and riser height for each step. Any additional measurements are helpful.
CORRECT MEASURING OF TREAD
RAMP INFORMATION1) Make a complete sketch of the ramp.2) Measure the length of ramp on angle and overall rise of ramp. These are the most critical dimensions for Wagner. 3) Measure angle of ramp if possible. Any additional measurments are helpful
STAIR INFORMATION
18
* It is recommended that a professional hand rail installer be involved in planning and installation of custom fabricated handrails.
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM20
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM 21
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM22
WAGNER ARCHITECTURAL | 888.243.6914 | [email protected] | WAGNERARCHITECTURAL.COM
WAGNER ARCHITECTURAL10600 W Brown Deer Rd
Milwaukee, WI 53224888.243.6914
091616