32
LT-979 Rev. 0 September 2009 Programming Manual 2 3 1 5 6 4 8 9 7 0 # * A B 7 * 2 3 1 5 6 4 8 9 7 0 # * A B 7 *

LT-979 TX3 Programming Manual Rev 0

Embed Size (px)

DESCRIPTION

2 3 1 5 6 4 8 9 7 8 9 7 A A 7 * 7 * B B TX3 Series Programming Manual i

Citation preview

LT-979 Rev. 0September 2009Programming Manual

2 31

5 64

8 97

0 #*

A

B

7

*

2 31

5 64

8 97

0 #*

A

B

7

*

TX3 Series Programming Manual

i

Contents

Keypad Navigation................................................................................................................... 1Entering Programming Mode.................................................................................................. 2

CONFIGURATION MENU .................................................................................................... 2OPERATION MENU ............................................................................................................. 2

Configuration Menu ................................................................................................................. 3DATABASE MENU ............................................................................................................... 3Add New Record................................................................................................................... 3Using keyless entry codes .................................................................................................... 5Selecting a ring pattern (NSL System only) .......................................................................... 5Edit Record ........................................................................................................................... 5Delete Record ....................................................................................................................... 6Sort By Name........................................................................................................................ 7Sort By d-code ...................................................................................................................... 7SYSTEM OPTION ................................................................................................................ 7Tone/Pulse mode.................................................................................................................. 8Line Type .............................................................................................................................. 8Main Door DTMF .................................................................................................................. 8Aux Door DTMF.................................................................................................................... 9Main Door Timer ................................................................................................................... 9Aux Door Timer..................................................................................................................... 9Talk Timer ............................................................................................................................. 9Language .............................................................................................................................. 10Welcome Message ............................................................................................................... 10Guard Phone......................................................................................................................... 10Calling Sch............................................................................................................................ 10Unlock Sch............................................................................................................................ 11Keycode Sch......................................................................................................................... 11Call Wait Key ........................................................................................................................ 12Keypad Active ....................................................................................................................... 12No of rings............................................................................................................................. 12Postal usage ......................................................................................................................... 13Scroll speed .......................................................................................................................... 13Day light Savin ...................................................................................................................... 13Clock adjustmen ................................................................................................................... 13Elevr Rest Tmr ...................................................................................................................... 14Speaker volume .................................................................................................................... 14MIC volume........................................................................................................................... 14SCHEDULE MENU............................................................................................................... 15Schedules ............................................................................................................................. 15Holidays ................................................................................................................................ 15Auto Program........................................................................................................................ 16Factory Default...................................................................................................................... 16Input/Output .......................................................................................................................... 17Correlation ............................................................................................................................ 18Change Passcode................................................................................................................. 19

Operation Menu........................................................................................................................ 20Set Time/Date ....................................................................................................................... 20View Logs ............................................................................................................................. 20

Speech Path.............................................................................................................................. 21Example Of Entry Panel Audio Line (or speech path) Designation ...................................... 21

Auto Programming................................................................................................................... 23

TX3 Series Programming Manual

1

Keypad Navigation

The following graphic provides the function of the command keys used to program the TX3.

2ABC

3DEF

1

5JKL

6MNO

4GHI

8TUV

9WXYZ

7PQRS

0* #

In the resident list,

press to scroll

page up and press to scroll page down.

In configuration mode

press to move left

and press to move right for checking and un-checking the check box

#

#

Press to enter

and confirm selection.

In the configuration

menu, press to scroll up and press

to scroll down.

Press to cancel the selection or exit mode

Entering Programming Mode

2

Entering Programming Mode

To enter programming mode, press the number 9 on the keypad, four times. You will now see the two main programming menus. One is the Configuration Menu and the other is the Operation Menu. The third item allows the user to view the configuration info. There are 3 levels of access. Level 1 does not require a password and allows access to resident names and dial codes only. Level 2 password allows access to the operation menu and Level 3 password allows access to both operation and configuration menu.

Once you select either Configuration or Operation, the following screen will appear, requesting your password.

Press “3333” (default password). The Configuration menu has the following list of programming functions that can be chosen:

CONFIGURATION MENUIf you select the Configuration Menu, you see a list of options (as you scroll down) as shown in the box below.

CONFIGURATION MENU

1. System Option

2. Database

3. Schedules

4. Holidays

5. Factory Dflt

6. Input/Output

7. Correlation

8. Change Passcode

OPERATION MENUWhen the Operation Menu is selected, the following operations are available (use the up/down keys to scroll through the menu):

OPERATION MENU

1. View logs

2. Delete logs

3. Set time & date

Main Menu1 Configuration

2 Operation

3. View Cfg Info

Enter the Password[ _ _ _ _ ]

TX3 Series Programming Manual

3

Configuration Menu

DATABASE MENUThe database menu is contained in the Configuration Menu. It consists of:

1. Add Record

2. Edit Record

3. Delete Record

4. Sort by name

5. Sort by d-code (sort by dial code)

6. Auto Program

7. Delete all Records

Add New Record

Entering resident namesAfter entering the configuration, select the database menu and press the telephone key to enter the Add Record menu. The display will show the following screen:

To enter a name, use the number keys to select the appropriate character. Maximum number of characters is 15. See the diagram below for the characters that correspond to each number.

To select a character, press any number key once, twice, three or more times to cycle through the characters associated with that key. When you reach the character you want, stop pressing the key and the character will remain in the display.

Note: Photocopy and then fill out the worksheets provided on pages 73 and 74 to record the resident information needed for adding new records.

Note: If you accidentally enter the wrong character while programming a name, press * once to backspace and delete the letter.

Enter Resident Name[ _ _ _ _ _ _ _ _ _ _ ]

2ABC

3DEF

1

5JKL

6MNO

4GHI

8TUV

9WXYZ

7PQRS

0* #

press once = commapress twice = dashpress 3 times = left bracketpress 4 times = right bracketpress 5 times = spacepress 6 times = 1

press once = 0press twice = space

press * once = backspace press # once = space

Configuration Menu

4

For example, to enter the last name “Doe”,

1. Press “3” four times for the capitol letter “D”.

2. Press “6” three times for the letter “o”.

3. Press “3” two times for the letter “e”.

4. Press the telephone key to save and continue.

Once you have entered the name (also include in this table), press the telephone key (enter) to accept. The following screens will appear as shown in the following table, one item at a time in this order.

When you are finished adding the new record, press Enter (the telephone key) the display will show “New Record Added”. The display will return to the programming menu.

Using keyless entry codesTo enter the premises with a keyless entry code, you must first be in normal mode. While in normal mode, press 9998, after which point you will be prompted with “Enter keyless code”. Enter your four-digit keyless code (can be up to six-digits) to automatically gain entrance to the premises.

Example: Four-digit keyless code

9998 + XXXX

Database Menu NSL System ADC System Explanation/Description

Enter Resident Name YES YESEnter the resident’s name. The name must be unique and a maximum of 15 characters.

Enter Apt No

[_ _ _ _]YES YES Enter the resident’s apartment number (up to 4 digits).

Enter Resident Name

[_ _ _ _]YES YES Enter the resident’s name (maximum 15 characters).

Enter Dial Code

_ _ _ _YES YES Enter the resident’s dial code (up to 4 digits).

Enter Keyless Code

[_ _ _ _]YES YES

Enter the assigned keyless code, up to 6 digits (if used). See below for using keyless entry codes.

Enter Relay Code

[_ _ _ _]YES N/A

Enter the resident’s assigned relay code.

Note: Relay codes start at 1 for the first relay, up to 1536.

Enter Telephone #

[____________] N/A YES

Enter the resident’s telephone number (up to 18 digits including a comma that is used as 1 second delay). Use the up arrow key for a comma and the down arrow key for a dash which is optional. Press the Enter (telephone key) to accept the telephone number.

Hide Res Name

[x] DisplayYES YES This feature turns the resident info display ON or OFF (HIDE). In the

Hide mode, the resident info is displayed when in configuration mode.

Enter Elev Rest Addr

[_ _]YES N/A

Enter the ID (or address) of the Elevator Restriction controller for the resident.

Enter Elev Rest Relay

[_ _] YES YES

Enter the elevator restriction relay number for the resident.Note: Relay codes start at 01 for first relay.

Keyless Corr

[x] Main door relay

[ ] Aux door relay

YES YESSelect which door (main, auxiliary or both) can be opened by the resident using a keyless code.

Line in Use

[x] Line 1 - 5YES YES

Enter the speech path for resident to communicate to the ADC line or to a relay control unit. Line 1 is default.

Enter Ring Pattern

[x] Ring Pattern 1-5YES N/A

Enter the ring pattern for the resident. See table following for available ring patterns. Default is 1.

TX3 Series Programming Manual

5

Selecting a ring pattern (NSL System only)

Edit Record1. Press the arrow key to “Edit Record” and use the up/down key to scroll through the residents and press the

telephone button to enter the resident name for editing.

2. Once the resident has been selected, use the down arrow key to scroll down the list of records, such as Apartment #, Resident name, Dial code Keyless code, relay code, telephone #, etc.

3. Once the arrow is pointing to the record that requires a change, press the telephone key to edit.

4. Re-enter the correct information. See page 3 for instructions on entering data.

When you are finished editing the record, the display returns to the record list. At this point you may edit another record or press info key to return to the configuration menu.

Delete Record1. Scroll the arrow to “Delete Record” and press the telephone button to enter the delete menu. You will see the

dial code and resident name as shown below:

2. Scroll the resident names with the up/down arrow keys to the record you wish to delete. There is a prompt to delete.

3. Press the telephone (enter) key to delete the entire record.

Once the record has been deleted, the screen will return to the Delete Record function. At this point you may delete other records or press the info key to return to the Configuration menu.

Ring Pattern Available Ring Pattern

1 2s ON 4s OFFstandard

ring A

2 800ms ON 400ms OFF 800ms ON 4s OFFdistinctring B

3 200ms ON 400ms OFF 200ms ON 400ms OFF 800ms ON 4s OFFdistinctring C

4 200ms ON 400ms OFF 800ms ON 400ms OFF 200ms ON 4s OFFdistinct

ring D

5 One single ringing burst

Note: There is no warning before deletion. This function deletes one record at a time.

1212>Smith1213 Jones

1214 Hath

1215 Johnson

1212>Smith1213 Jones

Configuration Menu

6

Sort By NameSelect this feature if you want the list of residents to be sorted alphabetically by name. Scroll the arrow to “Sort by Name” and press the enter (telephone) key. If you have just installed the system, you will see the following message:

The display now returns to the programming menu.

Sort By d-codeSelect this feature if you want the list of residents to be sorted numerically by dial code. Scroll the arrow to “Sort by d-code” and press enter (telephone) key. If you have just installed the system, you will see the following message:

The display now returns to the programming menu.

Auto ProgramThis selection allows you to chose the auto program to assign dial codes for a group of residents to add to the resident list

1. Scroll the arrow to “Auto Program” in the main Configuration menu and press the enter (telephone) key to select. The display will now show the following message:

2. Use the up arrow to move from number of residents in increments of 5 to the desired number. The maximum depends on the TX3 Model (it can be 200, 1000 or 2000)

3. Press the telephone (enter) key to accept. The next screen will ask for resident name. Enter one of the resident names using the alphanumeric keypad.

4. Press the telephone (enter) key to accept. The next screen will ask for the dial code for which this resident will have and all the rest will have dial code incremented by one.

5. Use the number keypad to enter the start dial code. The next screen will ask for the keyless code for which this same resident will have and all the rest will have a keyless code incremented by one.

6. Use the number keypad to enter the start keyless code. The next screen will ask for the which audio line to use (1 to 5 for NSL systems only).

7. Use the up arrow to enter the line number. Press the enter (telephone) key to enter.

Sorting please wait ...

Sorting please wait ...

Number of Records

< 010>

Enter Resident Name

Start Dial Code

Start Keyless Code

Line Number to use

TX3 Series Programming Manual

7

8. Press info key to return to previous menu. View the residents entered by scrolling page up and down using the * and # keys. To enter the proper resident names, use the edit feature.

Delete all RecordsSelect this feature if you want the delete all the resident data (all names, dial codes, everything). Scroll the arrow to “Delete all Records” and press the enter (telephone) key. You will see the following message:

Press the telephone key to accept or the info key to cancel. The display now returns to the programming menu.

SYSTEM OPTIONSelecting “System Option” from the Configuration Menu gives you the following configuration options:

1. Tone/Pulse mode

2. Line Type

3. Main Door DTMF

4. Aux Door DTMF

5. Main door timer

6. Aux door timer

7. Talk timer

8. Language

9. Welcome Message

10. Guard Phone

11. Calling Sch

12. Unlock Schedule

13. Keycode Sch

14. Call Wait Key

15. Keypad Active

16. No of rings

17. Postal usage

18. Scroll speed

19. Day light savin

20. Clock adjustmen

21. Elevr Rest Tmr.

22. Speaker volume

23. MIC volume

24. Select Font (only available on 8-line display)

Delete all records? Y

Configuration Menu

8

Tone/Pulse modeThe System Options Menu contains the tone/ pulse function. This function defines if the TX3 will operate with a digital phone line or a pulse phone line.

1. Scroll the arrow key to “Tone/Pulse mode” and press the telephone key. The display will now show the follow-ing message:

2. Use the ‘*” and or “#” key to move the x to make a selection.

3. Press the telephone key to enter.

Line TypeThe System Options Menu contains the Line Type function. This function defines the 5 speech lines of the TX3 Entry Control Panel. A selection is made for each line. The default is ADC for line 1 and unused for lines 2 to 5.

1. Scroll the arrow key to “Line Type” and press the telephone key. The display will now show the following mes-sage:

1. Select L-1 using the down arrow key, and press the telephone (enter) key. The following screen will show:

2. Use the ‘*” and or “#” key to move the x to make a selection.

3. Press the telephone key to enter.

Main Door DTMFThe System Options Menu contains the Main Door DTMF function. This function defines the key that the resident will press to open the main door. The default is 9.

1. Scroll the arrow key to “Main Door DTMF” and press the telephone key. The display will now show the follow-ing message:

2. Use the up or down key to move to the number of the key you would like to choose, then press * key and the telephone (enter) key to change the DTMF code. Valid numbers are 0 to 9.

3. Press info key to return to the programming menu.

Note: For pulse telephones, set the DTMF key to a number that is higher than five. This will avoid interpretive problems.

Tone/Pulse mode[ x ] Tone

[ ] Pulse

Line TypeL-1

L-2

L-3

Line Type[ x ] ADC Type

[ ] NSL Type

[ ] Unused

Main Door DTMF[ x ] ‘9’

[ ] ‘0’

TX3 Series Programming Manual

9

Aux Door DTMFThis function defines the key that resident will press to open the auxiliary door. The default is 6.

1. Scroll the arrow to “Aux Door DTMF” and press the telephone key. The display will now show the following message:

2. Use the up or down key to move to the number of the key you would like to choose, then press * key and the telephone (enter) key to change the DTMF code. Valid numbers are 0 to 9

3. Press the info key to return to the programming menu.

Main Door TimerThis function defines the length of time that the door will be unlocked after the resident enters the DTMF code to open the main door. The default is 10 seconds.

1. Scroll the arrow to “Main Door Timer” and press the telephone key. The display will now show the following message:

2. Use the up or down keys to choose the number of seconds. Valid programmable time is 5 to 60 seconds.

3. Press the info key to return to the programming menu.

Aux Door TimerThis function defines the length of time that the door will be unlocked after the resident enters the DTMF code. The default is 10 seconds.

1. Scroll the arrow to “Door Timer” and press the telephone key. The display will now show the following mes-sage:

2. Use the up or down keys to choose the number of seconds. Valid programmable time is 5 to 60 seconds.

3. Press the info key to return to the programming menu.

Talk TimerThis function defines the length of time that a visitor may be on the telephone with a resident. The default is 60 seconds.

1. Scroll the arrow to “Talk Timer” and press the telephone key. The display will now show the following message:

2. Use the up or down keys to choose the number of seconds. Valid time is from 10 to 300 seconds.

Aux Door DTMF[ ] ‘6’

[ ] ‘7’

[ ] ‘9’

Main Door Timer[ 010 ]

Auxiliary Door Timer[ 010 ]

Talk Timer[ 060 ]

Configuration Menu

10

3. Press the telephone key to return to the programming menu.

LanguageThe default language is English. If the Multi Language selection is entered, the opening screen flips through messages in English, French, and Spanish. Once a key is pressed, the language that is displayed on the screen at that moment will be used for all following messages.

1. Scroll the arrow to “Language” and press the telephone (enter) key. You will see the following screen:

2. Press info key to return to the programming menu.

Welcome MessageThis function allows the welcome message on the front of the TX3 Entry Control Panel to be changed.

1. Scroll the arrow to “Welcome Message” and press the telephone (enter) key. You will see the following screen:

2. Press the up arrow key to scroll to the next message line (Line-2) and scroll up again for next message (Line-3).

3. Once each message line has been edited, press the telephone (enter) key to accept.

4. Press info key to return to previous menu.

Guard PhoneThis feature is used if there is a guard phone to be installed at the TX3 Entry Control Panel. A Model TX3-GPM Guard Phone Module mounts over the main board of the TX3 Entry Panel.

1. Scroll the arrow to “Guard Phone” and press the telephone (enter) key.

2. Press the up arrow key to scroll to see the all 3 lines as shown below.

3. The default is no guard phone, use the * key to select the Guard Phone if required, and press the telephone (enter) key to accept.

4. Press info key to return to previous menu.

Calling SchThe calling schedule feature provides different days and/or times when calling is allowed.

1. Scroll the arrow to “Calling Sch” and press the telephone (enter) key.

Language

[ x ] English

[ ] French

[ ] Spanish

Enter Msg Line - 1

MIRCOM TX3 #1

Guard Phone

[ ] Guard Phone

[ x ] No Guard Phone

TX3 Series Programming Manual

11

2. Press the up and down arrow keys to scroll to see the all the defined schedules shown below. There are only two defined default schedules ALWAYS and NEVER, the other calling schedules shown below have been defined by the user. See section on Schedules.

3. The default is “Always”, use the up and down arrow keys to select the schedule required, and press the telephone (enter) key to accept. Note: Up to 64 schedules can be defined using the configurator software program.

4. Press info key to return to previous menu.

Unlock SchThis unlocking schedule feature provides different days and/or times when the resident is allowed to unlock the doors.

1. Scroll the arrow to “Unlock Sch” and press the telephone (enter) key.

2. Press the up and down arrow keys to scroll through all defined schedules as shown below.

3. The default is “Always”, use the up and down arrow keys to select the schedule required, and press the telephone (enter) key to accept.

4. Press info key to return to previous menu.

Keycode SchThis keycode schedule feature provides different times for keyless entry.

1. Scroll the arrow to “Keycode Sch” and press the telephone (enter) key.

Calling Sch

0 Always

1 Never

2 Weekdays

3 Weekend

4 Evenings

5 Holidays

Unlock Sch

0 Always

1 Never

2 Weekdays

3 Weekend

4 Evenings

5 Holidays

Configuration Menu

12

2. Press the up and down arrow keys to scroll through all defined schedules as shown below.

3. The default is “Always”, use the up and down arrow keys to select the schedule required, and press the telephone (enter) key to accept.

4. Press info key to return to previous menu.

Call Wait KeyThe call wait key feature provides selection of the specific key, which the resident presses to place the call on hold. This call wait feature applies to calling NSL only.

1. Scroll the arrow to “Call Wait Key” and press the telephone (enter) key.

2. Press the up and down arrow keys to scroll through keys available.

3. The default call wait key is 2, the range available is 1 to 9. Once selection is made using the up/down selection keys, press the (enter) key to accept.

4. Press info key to return to previous menu.

Keypad ActiveThis keypad active feature provides an active keypad during the call connection. May be required if residents answering machine picks up the call.

1. Scroll the arrow to “Keypad Active” and press the telephone (enter) key.

2. There two selections for Keypad Active, see below.

3. The default is “Active”, press the * key to change the selection and then the telephone (enter) key to accept.

4. Press info key to return to the previous menu.

No of ringsThis feature allows the selection of the maximum number of rings on the resident’s phone from the entry panel. This feature applies to calling NSL only.

1. Scroll the arrow to “No of rings” and press the telephone (enter) key.

2. The number of rings can be from 1 to 15, see below. Default is 7.

Unlock Sch

0 Always

1 Never

2 Weekdays

3 Weekend

4 Evenings

5 Holidays

Call Wait Key

[ 011 ]

Keypad Active

[ x ] Active

[ ] Not Active

No of Rings

[ 007 ]

TX3 Series Programming Manual

13

3. Use the up and down arrow keys to scroll through and select the number of rings, then press the telephone (enter) key to accept.

4. Press info key to return to the previous menu.

Postal usageThe postal usage feature provides the maximum number of times that a postal lock can be used per day.

1. Scroll the arrow to “Postal usage” and press the telephone (enter) key.

2. Press the up and down arrow keys to scroll through numbers.

3. The default is 4, the range is 1-20 and press the telephone (enter) key to accept.

4. Press info key to return to previous menu.

Scroll speedThe scroll speed feature provides selection of the relative scrolling speed for the Entry Panel LCD.

1. Scroll the arrow to “Scroll speed” and press the telephone (enter) key.

2. Press the up and down arrow keys to scroll through numbers.

3. The default is 5, the range is 1-10 and press the telephone (enter) key to accept.

4. Press info key to return to previous menu.

Day light SavinThe scroll speed feature provides selection of daylight savings time for the Entry Panel LCD. This feature (if active) automatically adjusts the time by 1 hour in the spring and the fall each year.

1. Scroll the arrow to “Day light Savin” and press the telephone (enter) key.

2. Press the up and down arrow keys to scroll through active or not active.

3. The default is active, use the “#” key to move the x to make a selection, then press the telephone (enter) key to accept.

4. Press info key to return to previous menu.

Clock adjustmenThe clock adjustment feature provides selection of the number of seconds to adjust the clock each day.

1. Scroll the arrow to “clock adjustmen” and press the telephone (enter) key.

Postal lock usage

[ 004 ]

Scroll speed

[ 005 ]

Day light saving

< x > Active

< > Not Active

Configuration Menu

14

2. Press the up and down arrow keys to scroll through numbers.

3. The default is 0, the range is -15 to 15. Use the up arrow key to increase (positive) the adjustment or the down arrow key to decrease (negative) the adjustment. Press the telephone (enter) key to accept.

4. Press info key to return to previous menu.

Elevr Rest TmrThe elevator restriction timer feature provides selection of the length of time during which the elevator can be accessed. The elevator restriction cabinet can house up to 96 Form C type relay contacts. These relay contacts are normally connected to the input circuits of the elevator manufacturer’s button controller. When a resident releases the door, a designated relay is energized to signal the elevator button controller to enable a particular floor select button on the elevator and disable all others. In effect, the elevator will be restricted to stop only on the selected floor. The time period for these relays to remain in an energized state depends on the timer period assigned. Please note that each elevator restriction cabinet can have only one common timer. The timer range is 5 to 600 seconds, with 60 seconds as the default.

1. Scroll the arrow to “Elevr Rest Tmr” and press the telephone (enter) key.

2. Press the up and down arrow keys to scroll through numbers.

3. The default is 60, the range is 5 to 600 seconds. Press the telephone (enter) key to accept the number in view.

4. Press info key to return to previous menu.

Speaker volumeThe speaker volume feature provides selection of the relative Entry Panel speaker volume.

1. Scroll the arrow to “Speaker volume” and press the telephone (enter) key.

2. Press the up and down arrow keys to scroll through numbers.

3. The default is 11, the range is 1-15 and press the telephone (enter) key to accept.

4. Press info key to return to previous menu.

MIC volumeThe microphone volume feature provides selection of the relative Entry Panel microphone volume.

1. Scroll the arrow to “MIC volume” and press the telephone (enter) key.

2. Press the up and down arrow keys to scroll through numbers.

3. The default is 5, the range is 1-15 and press the telephone (enter) key to accept.

Clock adjustment

[ 000 ]

Elev Rest Timer

[ 060 ]

Speaker volume

[ 011 ]

MIC volume

[ 005 ]

TX3 Series Programming Manual

15

4. Press info key to return to previous menu.

SCHEDULE MENUWithin the Configuration menu is the schedules menu. This menu is used to define the Calling Schedule (for accepting calls from the entry panel), Unlock Schedule (for unlocking the entry door), Postal Lock schedule, Holiday Schedules and any specific schedules required (including card readers). All the schedules can be defined here.

Schedules1. Scroll the arrow to “Schedules” in the main Configuration menu and press the enter (telephone) key to select.

The display will now show the following message:

2. You are able to add, edit or delete any schedule except Always (which is default) and Never.

3. If you select Add, the display will now show:

4. First create a label, then a start and end time. Then select the days of the week which are affected.

5. Selecting Edit or Delete will list all the schedules by label. Use the arrow keys to scroll to the schedule which you would like to edit or delete.

6. Press the telephone (enter) key to accept.

7. Press info key to return to previous menu.

Holidays1. Scroll the arrow to “Holidays” in the main Configuration menu and press the enter (telephone) key to select.

The display will now show the following message:

2. You are able to add, edit or delete any schedule. By default, there is only one holiday programmed into the system, NEW YEAR.

3. If you select Add, the display will now show:

4. First create a label, then a start date/time and end date/time. Then select if this is a annual occurrence.

5. Selecting Edit or Delete will list all the schedules by label. Use the arrow keys to scroll to the schedule which you would like to edit or delete.

6. Press the telephone (enter) key to accept.

7. Press info key to return to previous menu.

Schedule Options1 Add

2 Edit

3 Delete

Schedule Options1 Time Start

2 Time End

3 Days/ Holidays

Holiday Options1 Add

2 Edit

3 Delete

Enter LabelStart Time/Date

End Time/Date

Repeat Annually

Configuration Menu

16

Factory DefaultThis selection allows you to chose the factory default settings for the telephone access system.

1. Scroll the arrow to “Factory Dflt” in the main Configuration menu and press the enter (telephone) key to select. The display will now show the following message:

2. Use the up arrow to move from Y for yes and N for no.

3. Press the telephone (enter) key to accept.

4. Press info key to return to previous menu.

Input/OutputThis menu is used to define inputs and outputs

1. Scroll the arrow to “Input/Output” in the main Configuration menu, the selection will be as follows:

2. Select Inputs, and press the enter (telephone) key to select. The display will now show the following message:

3. Use the up and down arrows to move through the input types.

4. Select the input you wish to configure. Selections are Input 1, 2, 3, 4 and 5. For example the postal lock Input 1.

5. Press the telephone (enter) key to accept. The next screen will be the active state, then the circuit supervision and the alarm delay in seconds

6. Press info key to return to previous menu.

7. Select Outputs, and press the enter (telephone) key to select. The display will now show the following message:

8. Use the up and down arrows to move through the input types.

9. Select the output you wish to configure. For example Main Door Lock for output 1.

Note: Selecting the Factory Default does not delete any resident information.

Reset to default? <Y>

Ipt/Opt Options

1 Inputs

2 Outputs

Input Types

1 Postal lock

2 Fire P Override

3 Door Contact

4 GP Input 1

5 GP Input 2

Output Types

1 Main Door lock

2 Aux Door lock

3 GP Output 1

4 GP Output 2

TX3 Series Programming Manual

17

10.Press the telephone (enter) key to accept. The next screen will ask you to define the active state, either energized or de-energized.

11.Press info key to return to previous menu.

Opt Active State

< > De-energized

< x > Energized

Configuration Menu

18

CorrelationThis menu is used to correlate input and outputs.

1. Scroll the arrow to “Correlation” in the main Configuration menu and press the enter (telephone) key to select. The display will now show the following message:

1. Select Add and the following message appears:

2.

3. The next screen is,

4.

5.

Correlation1 Add

2 Edit

3 Delete

Event Type<X>Input Active

< >Call Started

< >Call Ended

< >Call Connected

< >Access Granted

< >Access Denied

< >System Normal

Event Data

1 Postal lock

2 Fire P Override

3 Door sense

4 GP Input 1

5 GP Input 2

Response Time

< >Turn Output ON

< x >Turn Output OFF

Response Data

< >GP Output 1

< x >GP Output 2

Schedule

0 Always

TX3 Series Programming Manual

19

6.

7.

Change Passcode1. Scroll the arrow to “Change Passcode” in the main Configuration menu and press the enter (telephone) key to

select. The display will now show the following message:

2. Use the up arrow to select the access level (three available).

3. Enter the new passcode for the access level you have chosen. It must be 10 digits long. If you forget the new password, call Mircom’s Technical Support Department (see Technical Support on page 2 for contact information). The display will now show the following message:

4. Press the enter (telephone) key to enter the new passcode. The display will now show the following message:

5. Press the enter (telephone) key to finalize the new passcode

6. Press info key return to the Configuration menu.

Corr Timer

[ 001]

Node Address

Enter Access Level< 001>

Enter new Passcode----------

Re-enter new Passcode----------

Operation Menu

20

Operation Menu

1. The Operation Menu is part of the main menu. When the Operation Menu is selected the following menus are displayed::

Set Time/Date1. Scroll the arrow to “Set Time/Date” in the Operation menu and press the telephone key to enter. The display

will now show the following message:

2. Enter the date and time using the keypad.

3. Press info key to accept and return to the programming menu.

View LogsScroll to “View logs” and press the enter (telephone) key to select. If you have just installed the system, you will see the following message:

If events have occurred such as the entering of dial codes and the opening of the main door, you will see this information listed on the display along with the date and time. See below for example:

The first four digits represent the index of logged events in sequence from 1 (0001) up to 1000. The next digits 08/10/99 represent the date as month, day and year, and are followed by the time in hours and minutes. The second line shows the four-digit code that was dialed to open the door. The following letter “D” indicates that the preceding number was a dial code (D = dial code, K = keyless code). The term “Acc:” represents the word “access”. The term “Yes” indicates that access was granted.

The display now returns to the programming menu.

Operation Menu1 View logs

2 Delete logs

3 Set time & date

Set Time/Date

Apr 14, 2009 03:23 PM

Logging data not present

0001 08/10/99 10:42 4321D Acc: Yes

TX3 Series Programming Manual

21

Speech Path

Example Of Entry Panel Audio Line (or speech path) DesignationIn the following example, there are five entry panels and two NSL units. Each entry panel must be given an ID (address) using the DIP switch on the main board. Every entry panel has 5 available audio lines or speech paths. The NSL units must:

• Talk to the front entry panel of Building #1.

• Talk to the front entry panel of Building #2.

• Talk to the parking garage entry panel.

This is a shared access setup. The back entry unit of Building #1 will only talk to the NSL in building #1 since it only needs to access Building #1. The back entry unit of Building #2 will only talk to the NSL in building #2 since it only needs to access Building #2. Below is a diagram that represents this example system.

BUILDING #2PARKING GARAGE

TX3-NSL-8M TX3-NSL-8M

BUILDING #1

AudioLine #1

AudioLine #1

AudioLine #2

AudioLine #1

2 31

5 64

8 97

0 #*

<<Mircom>>

2 31

5 64

8 97

0 #*

<<Mircom>>

2 31

5 64

8 97

0 #*

<<Mircom>>

2 31

5 64

8 97

0 #*

<<Mircom>>

2 31

5 64

8 97

0 #*

<<Mircom>>

FRONT ENTRYID=1

BACK LOBBYID=4

FRONT ENTRYID=2

BACK ENTRYID=5

Audio Line #from BackEntry ofBuilding 2.

Audio Line #1from BackEntry ofBuilding 1.

ID=3

Speech Path

22

In this example, we record the IDs and their speech path for each entry panel.

We then program the entry panel with address 1 in Building #1. Programming can be achieved by entering the configuration mode at the entry panel with the keypad or by using the TX3-MDM Configuration program and a computer. Enter all numerical values.

Once we have programmed entry panel 1, we will program the other entry panels. The entry panel of Building #2 with ID 2 will be entered in the same manner as outlined above.

The parking garage entry panel will be set up as shown below:

Entry Panel ID NSL Speech Path (SP) or Audio Line

1, Front Lobby Building #1

Building #1 1

2, Front Lobby Building #2

Building #2 1

3, Connected Parking Garage

Building #1 1

3, Connected Parking Garage

Building #2 2

4, Back Lobby Building #1

Building #1 4

5, Back Lobby Building #2

Building #2 4

ID 1, Line 1 NSL Cabinet Building 1

ID 2, Line 1 NSL Cabinet Building 2

Entry Panel ID NSL Speech Path (SP) or Audio Line

3, Connected Parking Garage

Building #1 1

3, Connected Parking Garage

Building #2 2

TX3 Series Programming Manual

23

Auto Programming

This function allows you to auto program the number of residents, resident name, start dial code, start keyless code, line number to use and start relay number. This feature is particularly useful when programming a large number of residents into the system.

1. Scroll the arrow to “Auto Program” function and press enter (telephone) key.

2. The following information will be requested on the display, beginning with the number of residents you wish to install.

Programming Menu NSL System

ADC System Explanation/Description

Number of Records

[____]YES YES

Enter the total number of residents to auto program (4 digits). Scroll up or down to the desired number, then press enter (telephone key). Must be 10 or more.

Enter Resident Name

[____________]YES YES Enter the resident’s name (maximum 14 characters).

Start Dialcode

[____]YES YES

Enter the start number of Dial Codes to auto program. The starting code will be entered in increments of 1, up to the number of residents entered. These codes are used by the visitors to call the residents by entering it on the keypad.

Start Keyless Code

[____]

Enter the start number of the keyless codes, if used. The starting code will be entered in increments of 1, up to the number of residents entered. These codes are used by the visitors to enter without calling the resident.

Line Number to use [__]

YES N/AEnter the Line number you wish for this lobby unit to connect to. This Line numbers will be used by the number of residents entered. Lines 1 to 5 are available.

Start Relay Number

[____]YES N/A

Enter the start relay number to auto program. The starting relay number will be entered in increments of 1, up to the number of residents entered. Please note that the relay number starts at 1 for the first relay.

24

Warranty & Warning Information

Warning Please Read Carefully Note to End Users: This equipment is subject to terms and conditions of sale as follows:

Note to Installers This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system. Failure to properly inform system end-users of the circumstances in which the system might fail may result in over-reliance upon the system. As a result, it is imperative that you properly inform each customer for whom you install the system of the possible forms of failure.

System Failures This system has been carefully designed to be as effective as possible. There are circumstances, such as fire or other types of emergencies where it may not provide protection. Alarm systems of any type may be compromised deliberately or may fail to operate as expected for a variety of reasons. Some reasons for system failure include:

•Inadequate Installation

A Fire Alarm system must be installed in accordance with all the applicable codes and standards in order to provide adequate protection. An inspection and approval of the initial installation, or, after any changes to the system, must be conducted by the Local Authority Having Jurisdiction. Such inspections ensure installation has been carried out properly.

•Power Failure

Control units, smoke detectors and many other connected devices require an adequate power supply for proper operation. If the system or any device connected to the system operates from batteries, it is possible for the batteries to fail. Even if the batteries have not failed, they must be fully charged, in good condition and installed correctly. If a device operates only by AC power, any interruption, however brief, will render that device inoperative while it does not have power. Power interruptions of any length are often accompanied by voltage fluctuations which may damage electronic equipment such as a fire alarm system. After a power interruption has occurred, immediately conduct a complete system test to ensure that the system operates as intended.

•Failure of Replaceable Batteries

Systems with wireless transmitters have been designed to provide several years of battery life under normal conditions. The expected battery life is a function of the device environment, usage and type. Ambient conditions such as high humidity, high or low temperatures, or large temperature fluctuations may reduce the expected battery life. While each transmitting device has a low battery monitor which identifies when the batteries need to be replaced, this monitor may fail to operate as expected. Regular testing and maintenance will keep the system in good operating condition.

•Compromise of Radio Frequency (Wireless) Devices

Signals may not reach the receiver under all circumstances which could include metal objects placed on or near the radio path or deliberate jamming or other inadvertent radio signal interference.

•System Users

A user may not be able to operate a panic or emergency switch possibly due to permanent or temporary physical disability, inability to reach the device in time, or unfamiliarity with the correct operation. It is important that all system users be trained in the correct operation of the alarm system and that they know how to respond when the system indicates an alarm.

•Automatic Alarm Initiating Devices

Smoke detectors, heat detectors and other alarm initiating devices that are a part of this system may not properly detect a fire condition or signal the control panel to alert occupants of a fire condition for a number of reasons, such as: the smoke detectors or heat detector may have been improperly installed or positioned; smoke or heat may not

TX3 Series Programming Manual

25

be able to reach the alarm initiating device, such as when the fire is in a chimney, walls or roofs, or on the other side of closed doors; and, smoke and heat detectors may not detect smoke or heat from fires on another level of the residence or building.

•Software

Most Mircom products contain software. With respect to those products, Mircom does not warranty that the operation of the software will be uninterrupted or error-free or that the software will meet any other standard of performance, or that the functions or performance of the software will meet the user’s requirements. Mircom shall not be liable for any delays, breakdowns, interruptions, loss, destruction, alteration or other problems in the use of a product arising our of, or caused by, the software.

Every fire is different in the amount and rate at which smoke and heat are generated. Smoke detectors cannot sense all types of fires equally well. Smoke detectors may not provide timely warning of fires caused by carelessness or safety hazards such as smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches or arson.

Even if the smoke detector or heat detector operates as intended, there may be circumstances when there is insufficient warning to allow all occupants to escape in time to avoid injury or death.

•Alarm Notification Appliances

Alarm Notification Appliances such as sirens, bells, horns, or strobes may not warn people or waken someone sleeping if there is an intervening wall or door. If notification appliances are located on a different level of the residence or premise, then it is less likely that the occupants will be alerted or awakened. Audible notification appliances may be interfered with by other noise sources such as stereos, radios, televisions, air conditioners or other appliances, or passing traffic. Audible notification appliances, however loud, may not be heard by a hearing-impaired person.

•Telephone Lines

If telephone lines are used to transmit alarms, they may be out of service or busy for certain periods of time. Also the telephone lines may be compromised by such things as criminal tampering, local construction, storms or earthquakes.

•Insufficient Time

There may be circumstances when the system will operate as intended, yet the occupants will not be protected from the emergency due to their inability to respond to the warnings in a timely manner. If the system is monitored, the response may not occur in time enough to protect the occupants or their belongings.

•Component Failure

Although every effort has been made to make this system as reliable as possible, the system may fail to function as intended due to the failure of a component.

•Inadequate Testing

Most problems that would prevent an alarm system from operating as intended can be discovered by regular testing and maintenance. The complete system should be tested as required by national standards and the Local Authority Having Jurisdiction and immediately after a fire, storm, earthquake, accident, or any kind of construction activity inside or outside the premises. The testing should include all sensing devices, keypads, consoles, alarm indicating devices and any other operational devices that are part of the system.

•Security and Insurance

Regardless of its capabilities, an alarm system is not a substitute for property or life insurance. An alarm system also is not a substitute for property owners, renters, or other occupants to act prudently to prevent or minimize the harmful effects of an emergency situation.

IMPORTANT NOTE: End-users of the system must take care to ensure that the system, batteries, telephone lines, etc. are tested and examined on a regular basis to ensure the minimization of system failure.

Warranty & Warning Information

26

Limited Warranty Mircom Technologies Ltd. together with its subsidiaries and affiliates (collectively, the “Mircom Group of Companies”) warrants the original purchaser that for a period of two years from the date of manufacture, the product shall be free of defects in materials and workmanship under normal use. During the warranty period, Mircom shall, at its option, repair or replace any defective product upon return of the product to its factory, at no charge for labor and materials. Any replacement and/or repaired parts are warranted for the remainder of the original warranty or ninety (90) days, whichever is longer. The original owner must promptly notify Mircom in writing that there is defect in material or workmanship, such written notice to be received in all events prior to expiration of the warranty period.

International Warranty The warranty for international customers is the same as for any customer within Canada and the United States, with the exception that Mircom shall not be responsible for any customs fees, taxes, or VAT that may be due.

Conditions to Void Warranty This warranty applies only to defects in parts and workmanship relating to normal use. It does not cover:

•damage incurred in shipping or handling;

•damage caused by disaster such as fire, flood, wind, earthquake or lightning;

•damage due to causes beyond the control of Mircom such as excessive voltage, mechanical shock or

•water damage;

•damage caused by unauthorized attachment, alterations, modifications or foreign objects;

•damage caused by peripherals (unless such peripherals were supplied by Mircom);

•defects caused by failure to provide a suitable installation environment for the products;

•damage caused by use of the products for purposes other than those for which it was designed;

•damage from improper maintenance;

•damage arising out of any other abuse, mishandling or improper application of the products.

Warranty Procedure To obtain service under this warranty, please return the item(s) in question to the point of purchase. All authorized distributors and dealers have a warranty program. Anyone returning goods to Mircom must first obtain an authorization number. Mircom will not accept any shipment whatsoever for which prior authorization has not been obtained. NOTE: Unless specific pre-authorization in writing is obtained from Mircom management, no credits will be issued for custom fabricated products or parts or for complete fire alarm system. Mircom will at its sole option, repair or replace parts under warranty. Advance replacements for such items must be purchased.

Note: Mircom’s liability for failure to repair the product under this warranty after a reasonable number of attempts will be limited to a replacement of the product, as the exclusive remedy for breach of warranty.

Disclaimer of Warranties This warranty contains the entire warranty and shall be in lieu of any and all other warranties, whether expressed or implied (including all implied warranties of merchantability or fitness for a particular purpose) And of all other obligations or liabilities on the part of Mircom neither assumes nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product.

This disclaimer of warranties and limited warranty are governed by the laws of the province of Ontario, Canada.

TX3 Series Programming Manual

27

Out of Warranty Repairs Mircom will at its option repair or replace out-of-warranty products which are returned to its factory according to the following conditions. Anyone returning goods to Mircom must first obtain an authorization number. Mircom will not accept any shipment whatsoever for which prior authorization has not been obtained.

Products which Mircom determines to be repairable will be repaired and returned. A set fee which Mircom has predetermined and which may be revised from time to time, will be charged for each unit repaired.

Products which Mircom determines not to be repairable will be replaced by the nearest equivalent product available at that time. The current market price of the replacement product will be charged for each replacement unit.

WARNING: Mircom recommends that the entire system be completely tested on a regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected.

NOTE: Under no circumstances shall Mircom be liable for any special, incidental, or consequential damages based upon breach of warranty, breach of contract, negligence, strict liability, or any other legal theory. Such damages include, but are not limited to, loss of profits, loss of the product or any associated equipment, cost of capital, cost of substitute or replacement equipment, facilities or services, down time, purchaser’s time, the claims of third parties, including customers, and injury to property.

MIRCOM MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ITS GOODS DELIVERED, NOR IS THERE ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, EXCEPT FOR THE WARRANTY CONTAINED HEREIN.

Canada 25 Interchange Way Vaughan, ON L4K 5W3 Tel: 905-660-4655 Fax: 905-660-4113

© Mircom 2009Printed in Canada Subject to change without prior notice

www.mircom.com

U.S.A. 4575 Witmer Industrial EstatesNiagara Falls, NY 14305Tel: 1-888-660-4655 Fax: 1-888-660-4113