8
+7+ ([FOXVLYH LQWHUQDO DFFHOHUDWLRQ FUHDWHV PD[LPXP SHUIRUPDQFH WR DFKLHYH PD[LPXP SURWHFWLRQ RI ÁXLG KDQGOLQJ V\VWHPV IURP XQZDQWHG VROLGV VHH LOOXVWUDWLRQ LQVLGH IRU GHWDLOV ,WV DGYDQFHG SDWHQWHG GHVLJQ EXLOGLQJ XSRQ WKH SHUIRUPDQFH /$.26 LV NQRZQ IRU QRZ DOVR UHPRYHV PRUH RI WKH ÀQHU VROLGV PLFURQV UHVXOWLQJ LQ KLJKHU DJJUHJDWH VROLGV UHPRYDO ,QGHSHQGHQWO\ WHVWHG 3URYHQ VXSHULRU IRU WRGD\·V GHPDQGLQJ ÀOWUDWLRQ UHTXLUHPHQWV )RU VHWWODEOH VROLGV RQO\ 7URXEOHIUHH RSHUDWLRQ DGYDQFHG SXUJLQJVROLGVKDQGOLQJ FRQFHSWV NHHS ÁXLGV FOHDQ DQG FRQFHQWUDWH VHSDUDWHG VROLGV 1R VFUHHQV RU ÀOWHU HOHPHQWV WR FOHDQ RU UHSODFH QR PHVV\ VHUYLFLQJ URXWLQHV 1R EDFNZDVKLQJ ]HUR ÁXLG ORVV RSWLRQV /RZ VWHDG\ SUHVVXUH ORVV &KRLFH RI SURÀOHV WR DFFRPPRGDWH VSDFHSLSLQJ OLPLWDWLRQV 6ZLUOH[ LQWHUQDO DFFHOHUDWLQJ VORWV IRU RSWLPXP VROLGVUHPRYDO SHUIRUPDQFH SDWHQWHG 9RUWXEH IRU HQKDQFHG VROLGV VHSDUDWLRQFROOHFWLRQ SDWHQWHG *URRYHG LQOHWRXWOHW FRQQHFWLRQV IRU HDV\ LQVWDOODWLRQ ,QOLQH LQOHWRXWOHW FRQÀJXUDWLRQ IRU VLPSOLÀHG SLSLQJ ORZSURÀ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ig h E c ie ncy P rodu c t T M H

LS-624 HTH Brochure

Embed Size (px)

Citation preview

Page 1: LS-624 HTH Brochure

LAKOS High E

cienc

y Pr

odu c

t TM

Page 2: LS-624 HTH Brochure
Page 3: LS-624 HTH Brochure
Page 4: LS-624 HTH Brochure
Page 5: LS-624 HTH Brochure
Page 6: LS-624 HTH Brochure

Series of LAKOS HTH 1950 separators used to keep sand our of customer cooling tower installation in Mexico.

LAKOS HTH 0500 used to keep water tower condenser free of solids in chilled water system.

LAKOS HTH 3500 used to keep wind-blown sand from damaging heat exchangers and other equipment in manufafacturing plant in New Mexico.

Page 7: LS-624 HTH Brochure
Page 8: LS-624 HTH Brochure

LAKOS High E

cienc

y Pr

odu c

t TM

Solids Collection – Zero Liquid Loss and Capture Separated Solids

Purge Options – Automated Solids Purge

Tower Basin Sweeping with HydroBoosters

• Captureseparatedsolidseasilyandreturnliquidback to system

• Removecollectedsolidswithoutinterruptingsystemflow

• Single(1)bagSolidsRecoveryVessel(SRV)availableintwosizes:16-inch(SRV-816)and33-inch(SRV-833)

• Three(3)bagClosedRecoveryVessel(CRS)for10”separators and larger

• Filterbagsavailablefrom10micronto50microns• Optionalindicatorpackageprovidesconvenientway

todeterminebagchange-outsonSRV-816,SRV-833andCRS-836B

• Optionaldrycontactavailableforremotemonitoring.CanbetiedtoBMS(BuildingManagementSystem)

• LowerwastewatertreatmentcostsFormoreinformation,seeLAKOSLiteratureLS-576andLS-622

• PurgeseparatedsolidsfromLAKOSSeparatorsatpre-determinedintervals.LAKOSControllersprovideoptionstocontrolandadjustpurgeintervalsandduration

• LAKOSPurgevalvesarecapableofhandlingalltypesoffine,fibrous,andmildlyabrasivesolids

• EFS:ElectricBatteryBackupFail-safevalveautomaticallyclosesthevalveintheeventofapowerfailure

• LAKOSControllersfeaturesolidstatereliability,thusremovingtheneed for routine maintenance

• AllLAKOSValvesareCEcompliantFormoreinformation,seeLAKOSLiteratureLS-238andLS-913

• PatentedLAKOSHydroBoosterscreatesweepingactiononthecoolingtowerbasinfloortoreduceunder-depositcorrosion,coolingtowernozzleclogging and extend cooling tower life

• HBandeHBHydroBoostersVortexingactionmovescoolingtowersolidstowardsthefiltrationsystembyusingdirectedturbulence,therebypreventingsolidsaccumulationonthebasinfloor,andremovingthefoodsourceforbiologicalactivity

• Minimizemanualbasincleaning,coolingtowermaintenance,riskofinjuryassociatedwithbasinfloorcleaning,andsystemdowntime

•HBandeHBHydroBoostersaredesignedfordurability and to resist cooling tower water chemicals

Filtered water sent downstream to chillers/heat exchangers

Solids are directed to LAKOS Separator

Filtered waterflows to LAKOSHydroBoosters

LAKOS Separatorand System

HydroBoosters

ToLAKOS

Separator

Cooling Tower

AutomaticBallValve

ABV2

CRS-836-B(ClosedRecovery

Vessel)

SRV-833(SolidsRecoveryVessel)

SRV-816