16
Liquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01 E 07/2000 Pressure range: 150 to 1013 mbar Suction volume flow: 50 to 270 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and robust construction with the following particular features: handling of nearly all gases and vapours non-polluting due to nearly isothermal compression oil-free, as no lubrication in the working chamber small quantities of entrained liquid can be handled easy maintenance and reliable operation low noise and nearly free of vibration wide choice of material, therefore applicable nearly everywhere incorporated central drain no metallic contact of the rotating parts The Sterling SIHI liquid ring vacuum pumps LPH 40106, LPH 40411 and LPH 40516 are single-stage ones. They can be applied without modification as compressors up to a compression pressure of 1,2 bar ( see catalogue part K). APPLICATION Handling and exhausting of dry and humid gases; entrained liquid can be handled during the normal duty. The pumps are applied in all fields where a pressure of 150...900 mbar must be created by robust vacuum pumps. Fields of application are for example: chemistry and pharmacy for distilling and degassing electrics industry for impregnation and drying plastics industry for degassing etc. NOTE During operation the pump must continously be supplied with service liquid, normally water, in order to eliminate the heat resulting from the gas compression and to replenish the liquid ring, because part of the liquid is leving the pump together with the gas. This liquid can be separated from the gas in a liquid separator ( see catalogue part accessories) It is possible to reuse the service liquid. The direction of rotation of the pump is clockwise, when looking from the drive end on the pump. GENERAL TECHNICAL DATA Pump type unit LPH 40106 LPH 40411 LPH 40516 Speed 50 Hz 60 Hz rpm 1450 1) 1740 Max. compression over pressure bar 0,8 1,5 1,5 Max. admissible pressure difference bar 1,5 1,5 1,5 1,2 2) 1,5 Hydraulic test (over pressure) bar 3 Moment of inertial of the rotating pump parts and of the water filling kg . 0,0375 0,05 0,065 Sound pressure level at a suction pressure of 200 mbar dB (A) 65 66 Min. pulley diameter permissible in case of V-belt drive mm 160 Max. gas temperature dry saturated °C °C 240 120 Service liquid max. admissible temperature max. viscosity max. density °C mm²/s kg/m³ 100 90 1200 volume up to shaft level Liter 3,5 4,5 5,5 Max. flow resistance of the heat exchanger bar 0,2 The combination of several limiting values is not admissible. 1) normal speed 2) for material design 42

LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

Embed Size (px)

Citation preview

Page 1: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

Liquid ring vacuum pumpssingle-stage

LPH 40106, LPH 40411, LPH 40516

VACUUM TECHNOLOGY LPH LI 2133.71120.54.01 E 07/2000

Pressure range: 150 to 1013 mbarSuction volume flow: 50 to 270 m³/h

CONSTRUCTION TYPE

Sterling SIHI liquid ring vacuum pumps are displacement pumps ofuncomplicated and robust construction with the following particularfeatures:

handling of nearly all gases and vapoursnon-polluting due to nearly isothermal compressionoil-free, as no lubrication in the working chambersmall quantities of entrained liquid can be handledeasy maintenance and reliable operationlow noise and nearly free of vibrationwide choice of material, therefore applicable nearly everywhereincorporated central drainno metallic contact of the rotating parts

The Sterling SIHI liquid ring vacuum pumps LPH 40106, LPH 40411and LPH 40516 are single-stage ones. They can be applied withoutmodification as compressors up to a compression pressure of 1,2 bar( see catalogue part K).

APPLICATION

Handling and exhausting of dry and humid gases; entrained liquid canbe handled during the normal duty. The pumps are applied in all fieldswhere a pressure of 150...900 mbar must be created by robustvacuum pumps.Fields of application are for example:

chemistry and pharmacy for distilling and degassingelectrics industry for impregnation and dryingplastics industry for degassing etc.

NOTE

During operation the pump must continously be supplied with serviceliquid, normally water, in order to eliminate the heat resulting from thegas compression and to replenish the liquid ring, because part of theliquid is leving the pump together with the gas. This liquid can beseparated from the gas in a liquid separator ( see catalogue partaccessories)It is possible to reuse the service liquid.The direction of rotation of the pump is clockwise, when looking fromthe drive end on the pump.

GENERAL TECHNICAL DATA

Pump type unit LPH 40106 LPH 40411 LPH 40516

Speed 50 Hz60 Hz

rpm 1450 1)

1740Max. compression over pressure bar 0,8 1,5 1,5

Max. admissible pressure difference bar 1,5 1,5 1,5 1,2 2)

1,5Hydraulic test (over pressure) bar 3Moment of inertial of the rotating pump parts and of thewater filling kg . m² 0,0375 0,05 0,065

Sound pressure levelat a suction pressure of 200 mbar

dB (A) 65 66

Min. pulley diameter permissiblein case of V-belt drive

mm 160

Max. gas temperature drysaturated

°C°C

240120

Service liquid max. admissible temperature max. viscosity max. density

°Cmm²/skg/m³

100 901200

volume up to shaft level Liter 3,5 4,5 5,5

Max. flow resistanceof the heat exchanger

bar 0,2

The combination of several limiting values is not admissible. 1) normal speed 2) for material design 42

Page 2: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

2

Material design

MATERIAL DESIGN

Item COMPONENTS 01 02 42

0001, 0002 Casing 0.6025 1.4408

0010, 0011 Guide disk 0.6025 1.4408

0030 Vane wheel impeller 2.1096.01 1.4027.05 1.4517

0035 Central body 0.6025 1.4581

0200 Shaft 1.4021 1.4401

0500, 0600 Mechanical seal Cr-steel / carbon / Perbunan Cr Ni Mo-steel / carbon/Viton

Sectional drawing LPH 40106, LPH 40411, LPH 40516

Page 3: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

3

Suction volume flow and power absorption LPH 40106

0

20

40

60

80

100

120

100

suction pressure

suct

ion

vo

lum

e fl

ow

1450 rpm

1740 rpmm³/h

200 300 400 600 1000mbar

LPH 40106

0

0,5

1

1,5

2

2,5

3

3,5

100

suction pressure

po

wer

ab

sorp

tio

n

kW

1450 rpm

1740 rpm

200 300 400 600 1000mbar

LPH 40106

The operating data is applicable under the following conditions:

• pumping medium: - dry air: 20°C - water vapour saturated air: 20°C • service liquid: - water: 15°C Compression pressure 1013 mbar (atmospheric pressure) The suction volume flow is applied to the suction pressure Tolerance of the volume flow 10% and of the power absorption 5% Max. fresh water need with the lowest suction pressure

Page 4: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

4

Suction volume flow and power absorption LPH 40411

0

20

40

60

80

100

120

140

160

180

200

100

suction pressure

suct

ion

vo

lum

e fl

ow

1450 rpm

1740 rpmm³/h

200 300 400 600 1000mbar

LPH 40411

0

1

2

3

4

5

100

suction pressure

po

wer

ab

sorp

tio

n

kW

1450 rpm

1740 rpm

200 300 400 600 1000mbar

LPH 40411

The operating data is applicable under the following conditions:

• pumping medium: - dry air: 20°C - water vapour saturated air: 20°C • service liquid: - water: 15°C Compression pressure 1013 mbar (atmospheric pressure) The suction volume flow is applied to the suction pressure Tolerance of the volume flow 10% and of the power absorption 5% Max. fresh water need with the lowest suction pressure

Page 5: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

5

Suction volume flow and power absorption LPH 40516

0

50

100

150

200

250

300

100

suction pressure

suct

ion

vo

lum

e fl

ow

1450 rpm

1740 rpm

m³/h

200 300 400 600 1000mbar

LPH 40516

0

1

2

3

4

5

6

7

100

suction pressure

po

wer

ab

sorp

tio

n

kW

1450 rpm

1740 rpm

200 300 400 600 1000mbar

LPH 40516

The operating data is applicable under the following conditions:

• pumping medium: - dry air: 20°C - water vapour saturated air: 20°C • service liquid: - water: 15°C Compression pressure: 1013 mbar (atmospheric pressure) The suction volume flow is applied to the suction pressure Tolerance of the volume flow 10% and of the power absorption 5% Max. fresh water need with the lowest suction pressure

Page 6: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

6

Dimension table LPH 40106

weight: abt. 50 kg

N 1 = gas inlet DN 40

N 2 = gas outlet DN 40

uB = connection for service liquid G ½

ue = drainage (screwed plug) G ¼

ue1 = drainage (screwed plug) G 1/8

ul = connection for vent cock G ½

um = connection for pressure gauge G ¼

um1 = connection for drain valve G ¼

flange connections to DIN 2501 PN 10

DN 40

k 110

D 150

number x d2 4 x 18

Page 7: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

7

Arrangement drawing LPH 40106 with overhead liquid separator

N 1 = gas inlet DN 40

N 2 = gas outlet DN 50

uA = connection for liquid drain G 1

uF = connection for fresh liquid 18 x 1

electric motor 50 Hz weight

size kW o1 * o2* abt. kg

IP 55 EEx e ll T3

2,2 - 373 836 117

LPH 40106 100L 3,0 -

- 2,5 437 900 112

flange connections to DIN 2501 PN 10

DN 40 50

k 110 125

D 150 165

number x d2 4 x 18 4 x 18

* dimensions dependent on the motor make

Page 8: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

8

Arrangement drawing LPH 40106 with upright liquid separator

N 1 = gas inlet DN 40

N 2 = gas outlet DN 50

uA = connection for liquid drain G 1

ue1 = drain connection G ½

uF = connection for fresh liquid 18 x 1

uFl = connection for liquid level indicator G ½

electric motor 50 Hz weight

size kW o1 * o2* abt. kg

IP 55 EEx e ll T3

2,2 - 373 836 135LPH 40106 100L 3,0 -

- 2,5 437 900 130

flange connections to DIN 2501 PN 10

DN 40 50k 110 125D 150 165

number x d2 4 x 18 4 x 18* dimensions dependent on the motor make

Page 9: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

9

Dimension table LPH 40411

weight: abt. 65 kg

N 1 = gas inlet DN 40

N 2 = gas outlet DN 40

uB = connection for service liquid G ½

ue = drainage ( screwed plug) G ¼

ue1 = drainage ( screwed plug) G 1/8ul = connection for vent cock G ½um = connection for pressure gauge G ¼um1 = connection for drain valve G ¼

flange connections to DIN 2501 PN 10

DN 40

k 110

D 150

number x d2 4 x 18

Page 10: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

10

Arrangement drawing LPH 40411 with over head liquid separator

N 1 = gas inlet DN 40

N 2 = gas outlet DN 50

uA = connection for liquid drain G 1

uF = connection for fresh liquid 18 x 1

electric motor 50 Hz weight

size kW o1 * o2* abt. kgIP 55 EEx e ll T3

112M 4,0 - 394 906 150

LPH 40411 - 3,6 380 892

132S - 5,0 485 997 165

flange connections to DIN 2501 PN 10

DN 40 50

k 110 125

D 150 165

number x d2 4 x 18 4 x 18

* dimensions dependent on the motor make

Page 11: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

11

Arrangement drawing LPH 40411 with upright liquid separator

N 1 = gas inlet DN 40

N 2 = gas outlet DN 50

uA = connection for liquid drain G 1

ue1 = drain connection G ½

uF = connection for fresh liquid 18 x 1

uFl = connection for liquid level indicator G ½

electric motor 50 Hz weight

size kW o1 * o2* abt. kgIP 55 EEx e ll T3

112M 4,0 - 394 906 165

LPH 40411 - 3,6 380 892

132S - 5,0 485 997 180

flange connections to DIN 2501 PN 10

DN 40 50k 110 125D 150 165

number x d2 4 x 18 4 x 18* dimensions dependent on the motor make

Page 12: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

12

Dimension table LPH 40516

weight: abt. 85 kg

N 1 = gas inlet DN 50

N 2 = gas outlet DN 50

uB = connection for service liquid G ½ue = drainage ( screwed plug) G ¼ue1 = drainage ( screwed plug) G 1/8ul = connection for vent cock G ½um = connection for pressure gauge G ¼um1 = connection for drain valve G ¼

flange connections to DIN 2501 PN 10

DN 50

k 125

D 165

number x d2 4 x 18

Page 13: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

13

Arrangement drawing LPH 40516 with overhead liquid separator

N 1 = gas inlet DN 50

N 2 = gas outlet DN 65

uA = connection for liquid drain G 1½

uF = connection for fresh liquid G ½

electric motor 50 Hz weight

size kW o1 * o2* abt. kgIP 55 EEx e ll T3

LPH 40516 132S 5,5 - 454 1017 190132M - 6,8 485 1048 200

flange connections to DIN 2501 PN 10

DN 50 65

k 125 145

D 165 185

number x d2 4 x 18 4 x 18

* dimensions dependent on the motor make

Page 14: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

14

Arrangement drawing LPH 40516 with upright liquid separator

N 1 = gas inlet DN 50

N 2 = gas outlet DN 80

uA = connection for liquid drain DN 32

ue1 = drain connection G ½

uF = connection for fresh liquid 18 x 1

uFl = connection for liquid level indicator G ½

electric motor 50 Hz weight

size kW o1 * o2* abt. kgIP 55 EEx e ll T3

LPH 40516 132S 5,5 - 454 1017 205132M - 6,8 485 1048 215

flange connections to DIN 2501 PN 10

DN 32 50 80k 100 125 160D 140 165 200

number x d2 4 x 18 4 x 18 8 x 18* dimensions dependent on the motor make

Page 15: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

15

Fresh water requirements in [m³/h] dependent on suction pressure, speed, mode of operation and difference in temperature

suction pressure in[mbar]

150 400 600 900

KB KB KB KB

pump speed[rpm]

difference intemperature [°C]

FB difference intemperature [°C]

FB difference intemperature [°C]

FB difference intemperature [°C]

FB

20 10 5 2 20 10 5 2 20 10 5 2 20 10 5 2

LPH 40106 1450 0,08 0,15 0,25 0,42 0,08 0,14 0,22 0,37 0,06 0,11 0,17 0,26 0,4 0,04 0,06 0,10 0,14

1740 0,11 0,19 0,31 0,49 0,8 0,10 0,17 0,27 0,41 0,65 0,08 0,14 0,20 0,29 0,06 0,09 0,13 0,16

LPH 40411 1450 0,12 0,21 0,33 0,51 0,11 0,19 0,30 0,44 0,09 0,16 0,24 0,35 0,5 0,05 0,08 0,12 0,16 0,2

1740 0,16 0,26 0,39 0,57 0,14 0,23 0,34 0,48 0,12 0,19 0,28 0,38 0,07 0,11 0,14 0,17

LPH 40516 1450 0,19 0,35 0,58 0,98 1,8 0,18 0,32 0,52 0,83 1,4 0,16 0,27 0,42 0,65 1 0,08 0,11 0,14 0,17

1740 0,24 0,43 0,70 1,10 0,22 0,39 0,60 0,92 0,20 0,33 0,49 0,71 0,10 0,13 0,16 0,18

FB = fresh liquid serviceKB = combined liquid service with service water 20 °C, 10 °C, 5 °C, 2 °C warmer than the fresh water.

Data regarding the pump size - order notes

series +size

hydraulics + bearings shaft sealing material design casing seal

B•

•N

2 antifriction bearings

1 shaft end, clockwise135 mechanical seal,

SIHI-FN

01

02

42

main parts of iron cast

main parts of ironcast, without non-ferrous metal

main parts of Cr NiMo-cast steel

0 liquid seal

40106

LPH 40411 BN 135 01, 02 ,42 0

40516

Design - Motor selection table

designation electric motor 50 Hz

pump with free shaft end 01 motor enclosure IP 55 motor enclosure EEx e ll T3

pump with coupling, pre-drilled at motor side 04 kW size designation. kW size designation

as above, but with motor, 2,2 100 L KB 2,5 100 L LKfor example 3 kW three-phase motor e.g. LB 3,0 100 L LB 3,6 112 M MK

(50 Hz, 230 V∆) at 1450 rpm 4,0 112 M MB 5,0 132 S NK5,5 132 S NB 6,8 132 M PK

Example for ordering:

The construction size LPH 40106 BN 135 02 0 with 3 kW three phase ac motor (50 Hz, 230 V∆) 1450 rpmhas the complete order number: LPH• 40106 BN 135 02 0 LB

If motors with other voltage or frequency are required a special information should be given.

On delivery the point (•) in the fourth place of the type code is replaced by a letter in the factory.

Page 16: LPH 40106, LPH 40411, LPH 40516 - contvac.comcontvac.com/pdf/li2.pdfLiquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.54.01

16

Accessories

Recommended accessories LPH 40106 LPH 40411 LPH 40516

Overhead liquid separator typeweight

XBa 104010 kg

XBa 134014 kg

XBa 134115 kg

material design 130 / galvanized172 / 1.4571

SIHI part No. 35 000 38835 000 389

35 000 40835 000 409

35 000 41235 000 413

service liquid line

material design 072 / St 37-0172 / 1.4571

SIHI part No. 35 003 05935 015 912

35 003 05735 003 058

35 003 06635 003 067

Upright liquid separator typeweight

XBp 41328 kg

XBp 41431 kg

material design 130 / galvanized172 / 1.4571

SIHI part No. 35 000 50235 000 503

35 000 50435 000 505

service liquid line

material design 072 / St 37-0172 / 1.4571

SIHI part No. 35 003 07135 003 072

35 003 07335 003 074

35 003 07035 013 850

discharge line

material design 072 / St 37-0172 / 1.4571

SIHI part No. 35 003 16535 003 166

35 003 16335 003 164

35 003 20335 003 205

Non-return valve type / weight XCk 40 / 2,8 kg resp. 5,2 kg XCk 50 / 3,6 kgresp. 10,8 kg

material design 767 / GG-25 + Perbunan784 / 1.4408 + Teflon

SIHI part No. 43 016 89043 030 996

43 016 89243 039 284

Motor in case of standard designIP 55 size

powerweight

100 L2,2 kW24 kg

100L3 kW26 kg

112 M4 kW31 kg

132 S5,5 kW45 kg

EEx e ll T3 sizepowerweight

100 L2,5 kW22 kg

112 M3,6 kW30 kg

132 S5 kW45 kg

132 M6,8 kW50 kg

Couplingfor motor IP 55 pump side motor side

type / weightSIHI part No.

B 80 / 1,5 kg43 021 41443 021 417

B 95 / 2,6 kg43 021 42643 021 433

for motor EEx e II T3 pump side motor side

type / weightSIHI part No.

BDS 88 / 2 kg43 028 11243 024 707

BDS 103 / 3 kg43 026 56443 025 941

Contact safety device material design 076 / steel SIHI part No. 43 042 222 43 042 248

345 / 2.0321 43 042 223 43 042 249

Base frame type / weight S 301 / 27 kg S 342 / 35 kg S 303 / 34 kg material design 081 / RSt 37-2 SIHI part No. 43 040 634 43 040 636 43 040 635

Any changes in the interest of the technical development are reserved.

S t e r l i n g S I H I G m b HLindenstraße 170, D-25524 Itzehoe, Germany, Telephone +49 (0) 48 21 / 7 71 - 01, Fax +49 (0) 48 21 / 7 71-274