10
Ship-Set Quantities Available! We are stocking a wide range of material to satisfy your immediate needs. Easy Identification! Our low smoke, zero halogen cable is color coded to IEEE-45. Reduced time and labor costs! This ABS-approved cable offers flexible stranding and is easy to strip and terminate. Tested and approved to IEC standards! This LSZH cable meets IEC standards for flame retardation, smoke density and halogen content. Top construction rating! Cable construction is XLPE Insulation/SHF-1 Jacket. LOW SMOKE ZERO HALOGEN CABLE FOR MARINE APPLICATIONS Contact Summit’s Marine Division and order your low smoke, halogen free cable today! Call 888.326.5174 or email [email protected] Low smoke, zero halogen marine cable is in stock at Summit’s Marine Division. Fires on board vessels can produce toxic gases and heavy smoke. Our marine low smoke, zero halogen cable can minimize the effects from these dangers. Save lives, protect your equipment from damage, and meet specifications that require use of LSZH cable. This cable is a low-cost alternative to the military spec cable often used in commercial applications. Get fast turn around and low minimums on non-stock items and special constructions. IN STOCK NOW!

Low Smoke - Summit Electric Supply · PDF fileOur low smoke, zero ... • Tested and approved to IEC standards! This LSZH cable meets IEC standards for flame retardation, smoke densityand

  • Upload
    ngotruc

  • View
    224

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Low Smoke - Summit Electric Supply · PDF fileOur low smoke, zero ... • Tested and approved to IEC standards! This LSZH cable meets IEC standards for flame retardation, smoke densityand

•Ship-Set Quantities Available!Wearestockingawiderangeofmaterialtosatisfyyourimmediateneeds.

•Easy Identification!Ourlowsmoke,zerohalogencableiscolorcodedtoIEEE-45.

•Reduced time and labor costs!ThisABS-approvedcableoffersflexiblestrandingandiseasytostripandterminate.

•Tested and approved to IEC standards!ThisLSZHcablemeetsIECstandardsforflameretardation,smokedensityandhalogencontent.

•Top construction rating!CableconstructionisXLPEInsulation/SHF-1Jacket.

Low SmokeZero HaLogen Cable for marine appliCations

Contact Summit’s Marine Division and order your low smoke, halogen free cable today!

[email protected]

Low smoke, zero halogen marine cable is in stock at Summit’s Marine Division.Firesonboardvesselscanproducetoxicgasesandheavysmoke.Ourmarinelowsmoke,zerohalogencablecanminimizetheeffectsfromthesedangers.

Savelives,protectyourequipmentfromdamage,andmeetspecificationsthatrequireuseofLSZHcable.Thiscableisalow-costalternativetothemilitaryspeccableoftenusedincommercialapplications.

Get fast turn around and low minimums on non-stock items and special constructions.

in

stoCk

now!

Page 2: Low Smoke - Summit Electric Supply · PDF fileOur low smoke, zero ... • Tested and approved to IEC standards! This LSZH cable meets IEC standards for flame retardation, smoke densityand

2

m2XHpower anD Control Cable

2

341

1

2

3

4

Cable Structure

Production and Test Standards

Application

- CONDUCTOR:Electrolytic,stranded,annealedcopperwire.IEC60228Class5 (Class2and/ortinnedonrequest).

- INSULATION:Lowsmoke,halogenfree,crosslinked,polyethylenecompound(XLPE).

- SEPARATOR:Separatingfoilorhalogenfree,beddingcompoundonrequest.

- OUTER SHEATH:Lowsmoke,halogenfree,flameretardant,thermoplastic,polyolefin-based compound(HM4/SHF1)-HD604.Color:Gray.

Usedasfixedinstallationcablesinvariouselectromechanicalandelectronicequipmentofmarinevehicles.Usableinallconditionsofamarineenvironmentsuchasdry,wetoroilylocations.

CONSTRUCTION.................................. IEC60092/353TESTSANDMATERIAL......................... IEC60092/350-351-359FLAMERETARDATION.......................... IEC60332/1,IEC60332/3CatAHALOGENCONTENT............................ IEC60754/1-2SMOKEDENSITY................................. IEC61034/1-2(DINEN50268/1-2)WORKINGTEMPERATURE..................... -40°C/+90°CMIN.BENDINGRADIUS(FIXED)............ 6xOverallDiameterRATEDVOLTAGE................................. 0.6/1kVTESTVOLTAGE.................................... 3.5kV

www.summit.com

Page 3: Low Smoke - Summit Electric Supply · PDF fileOur low smoke, zero ... • Tested and approved to IEC standards! This LSZH cable meets IEC standards for flame retardation, smoke densityand

3

m2XHpower anD Control Cable

Part # Sizes (mm2) Designation O.D. in Inches

1758026 2x1.5 (D-3) 0.33

1758027 2x2.5 (D-4) 0.37

1758028 2x4 (D-6) 0.41

1758029 2x6 (D-10) 0.46

1758030 3x1.5 (T-3) 0.35

1758031 3x2.5 (T-4) 0.39

1963121 2x16 (D-26) 0.62

1963122 2x25 (D-41) 0.82

1758032 3x4 (T-6) 0.44

1758033 3x6 (T-10) 0.49

1758034 3x10 (T-16) 0.57

1758035 3x16 (T-26) 0.67

1758036 3x25 (T-41) 0.88

1758037 3x35 (T-66) 0.98

1758038 3x50 (T-106) 1.12

1758039 3x70 (T-133) 1.32

1758040 3x95 (T-212) 1.48

1758041 3x120 (T-250) 1.66

1859977 3x240 (T-500) 2.30

1758042 3x150 (T-300) 1.83

1758043 3x185 (T-400) 2.04

1758044 4x1.5 (F-3) 0.39

1758045 4x2.5 (F-4) 0.43

1758046 4x4 (F-6) 0.49

1758047 4x6 (F-10) 0.54

1758048 4x10 (F-16) 0.63

1758049 4x16 (F-26) 0.73

1758050 4x25 (F-41) 0.97

1758051 4x35 (F-66) 1.08

1758052 4x50 (F-106) 1.26

1758053 4x70 (F-133) 1.46

1758054 4x95 (F-212) 1.67

1758055 4x120 (F-250) 1.85

1758069 4x150 (F-300) 2.04

1758070 4x185 (F-400) 2.30

1758056 7x1.5 (M-7-3) 0.46

1758057 7x2.5 (M-7-4) 0.51

1758058 10x1.5 (M-10-3) 0.59

1758059 10x2.5 (M-10-4) 0.66

1971917 12x4 (M-12-6) 0.79

1758060 14x1.5 (M-14-3) 0.64

1758061 14x2.5 (M-14-4) 0.71

1758062 20x1.5 (M-20-3) 0.71

1758063 20x2.5 (M-20-4) 0.80

1859982 24x1.5 (M-24-3) 0.84

1758064 30x1.5 (M-30-3) 0.90

1758065 30x2.5 (M-30-4) 1.04

1990092 37x1.5 (M-37-3) 0.97

www.summit.com

Page 4: Low Smoke - Summit Electric Supply · PDF fileOur low smoke, zero ... • Tested and approved to IEC standards! This LSZH cable meets IEC standards for flame retardation, smoke densityand

4

m2XCHsHielDeD Control Cable

2

34

1

1

2

3

4

Cable Structure

Production and Test Standards

Application

- CONDUCTOR:Electrolytic,stranded,annealedcopperwire.IEC60228Class5. (Class2and/ortinnedonrequest.)

- INSULATION:Lowsmoke,halogenfree,crosslinked,polyethylenecompound(XLPE).

- SHIELD:Electrolytic,copper-braidedshield(90%coverage).M2XCH(EMC)typeiswrappedby acoppertapeinadditiontothisshield(100%coverage).

- OUTER SHEATH:Lowsmoke,halogenfree,flameretardant,thermoplastic,polyolefin-based compound(HM4/SHF1)-HD604.Color:Gray.

Usedasfixedinstallationcablesinvariouselectromechanicalandelectronicequipmentofmarinevehicles.Usableinallconditionsofamarineenvironmentsuchasdry,wetoroilylocations.

CONSTRUCTION................................................. IEC60092/353TESTSANDMATERIAL........................................ IEC60092/350-351-359FLAMERETARDATION......................................... IEC60332/1,IEC60332/3CatAHALOGENCONTENT........................................... IEC60754/1-2SMOKEDENSITY................................................ IEC61034/1-2(DINEN50268/1-2)SHIELDINGEFFECTIVENESS(forEMCtype)..........DINEN50147-1WORKINGTEMPERATURE.................................... -40°C/+90°CMIN.BENDINGRADIUS(FIXED)...........................8xOverallDiameterRATEDVOLTAGE................................................0.6/1kVTESTVOLTAGE...................................................3.5kV

Part # Sizes (mm2) Designation O.D. in Inches

1826903 4x2.5 (FS4) 0.47

1983712 4x25 (FS41) 1.04

1826902 6x2.5 (FS6) 0.57

1758016 7x1.5 (MS-7-3) 0.50

1758017 7x2.5 (MS-7-4) 0.57

1758018 10x1.5 (MS-10-3) 0.64

1758019 10x2.5 (MS-10-4) 0.71

1758020 14x1.5 (MS-14-3) 0.70

1758021 14x2.5 (MS-14-4) 0.77

1758022 20x1.5 (MS-20-3) 0.78

1758023 20x2.5 (MS-20-4) 0.85

1758024 30x1.5 (MS-30-3) 0.95

1758025 30x2.5 (MS-30-4) 1.06

www.summit.com

Page 5: Low Smoke - Summit Electric Supply · PDF fileOur low smoke, zero ... • Tested and approved to IEC standards! This LSZH cable meets IEC standards for flame retardation, smoke densityand

5

Fm2XaHoVerall sHielDeD instrUmentation Cable

7

1

2

3

4

5

6

7

Cable Structure

Production and Test Standards

Application

- CONDUCTOR:Electrolytic,stranded,annealedcopperwire.IEC60228Class5 (Class2and/ortinnedonrequest).- INSULATION:Lowsmoke,halogenfree,crosslinked,polyethylenecompound(XLPE). Layup:Coreslaidupinpairs;pairslaidupconcentrically.- SEPARATOR:Separatingfoilbelowshield.- DRAIN WIRE:Electrolytic,tinned,stranded,copperdrainwirebelowshield.- SHIELD:Aluminumtapeshield(100%coverage).- SEPARATOR:Separatingfoilaboveshield.- OUTER SHEATH:Lowsmoke,halogenfree,flameretardant,thermoplastic,polyolefin-based compound(HM4/SHF1)-HD604.Color:Gray.

Usedascontrolandcommunicationcablesinradio,radarandinformationsystemsformarineapplications.Enablespropertransmissionofhighfrequencysignalswhileminimizingenvironmentalelectromagneticinterference.Usableinallconditionsinmarineenvironmentsuchasdry,wetoroilylocations,andinsideenginerooms.

CONSTRUCTION................................................. IEC60092/375-376TESTSANDMATERIAL........................................ IEC60092/350-351-359FLAMERETARDATION......................................... IEC60332/1,IEC60332/3CatAHALOGENCONTENT........................................... IEC60754/1-2SMOKEDENSITY................................................ IEC61034/1-2(DINEN50268/1-2)WORKINGTEMPERATURE.................................... -40°C/+90°CMIN.BENDINGRADIUS(FIXED)...........................8xOverallDiameterRATEDVOLTAGE................................................60/250VTESTVOLTAGE...................................................1.5kV

1

2356

4

Part # Sizes (mm2) Designation O.D. in Inches

1758013 1x2x1.5 (TPS16-1P) 0.37

1758014 1x2x.75 (TPS18-1P) 0.31

1758015 1x2x.50 (TPS20-1P) 0.28

1758068 1x3x1.5 (TTS16-1) 0.39

www.summit.com

Page 6: Low Smoke - Summit Electric Supply · PDF fileOur low smoke, zero ... • Tested and approved to IEC standards! This LSZH cable meets IEC standards for flame retardation, smoke densityand

6

Fm2XaaHinDiViDUallY & oVerall sHielDeD instrUmentation Cable

10

1

2

3

4

5

6

7

8

9

10

Cable Structure

Production and Test Standards

- CONDUCTOR:Electrolytic,stranded,annealedcopperwire.IEC60228Class5 (Class2and/ortinnedonrequest).

- INSULATION:Lowsmoke,halogenfree,crosslinked,polyethylenecompound(XLPE). Layup:Coreslaidupinpairs/triads;pairs/triadslaidupconcentrically.

- SEPARATOR:Separatingfoiloverpairs/triads

- DRAIN WIRE:Electrolytic,tinned,stranded,copperdrainwirealongeachpair/triad.

- INDIVIDUAL SHIELD:Aluminumtapeshieldovereachpair/triadanddrain-wire bunch(100%coverage).

- SEPARATOR:Separatingfoilaboveshieldorinnersheath(onrequest).

- DRAIN WIRE:Electrolytic,tinned,stranded,copperdrainwirebelowoverallshield.

- OVERALL SHIELD:Aluminumtapeoverallshield(100%coverage).

- SEPARATOR:Separatingfoiloveroverallshield.

- OUTER SHEATH:Lowsmoke,halogenfree,flameretardant,thermoplastic, polyolefin-basedcompound(HM4/SHF1)–HD604.Color:Gray.

CONSTRUCTION................................................. IEC60092/376TESTSANDMATERIAL........................................ IEC60092/350-351-359FLAMERETARDATION......................................... IEC60332/1,IEC60332/3CatAHALOGENCONTENT........................................... IEC60754/1-2SMOKEDENSITY................................................ IEC61034/1-2(DINEN50268/1-2)WORKINGTEMPERATURE.................................... -40°C/+90°CMIN.BENDINGRADIUS(FIXED)...........................10xOverallDiameterRATEDVOLTAGE................................................60/250VTESTVOLTAGE...................................................1.5kV

12

3

47568

9

www.summit.com

Page 7: Low Smoke - Summit Electric Supply · PDF fileOur low smoke, zero ... • Tested and approved to IEC standards! This LSZH cable meets IEC standards for flame retardation, smoke densityand

7

ApplicationUsedascontrolandcommunicationcablesinradio,radarandinformationsystemsformarineapplications.Enablespropertransmissionofhighfrequencysignalswhileminimizingenvironmentalelectromagneticinterference.Usableinallconditionsinmarineenvironmentsuchasdry,wetoroilylocations,andinsideenginerooms.

Part # Sizes (mm2) Designation O.D. in Inches

1758001 2x2x1.5 (TPS16-2P) 0.61

1758002 2x2x.75 (TPS18-2P) 0.50

1758003 2x2x.50 (TPS20-2P) 0.46

1758004 4x2x1.5 (TPS16-4P) 0.72

1758005 4x2x.75 (TPS18-4P) 0.58

1758006 4x2x.50 (TPS20-4P) 0.54

1758007 6x2x1.5 (TSP16-6P) 0.87

1758008 6x2x.75 (TPS18-6P) 0.70

1758009 6x2x.50 (TPS20-6P) 0.65

1758010 10x2x1.5 (TPS16-10P) 1.08

1758011 10x2x.75 (TPS18-10P) 0.87

1758012 10x2x.50 (TPS20-10P) 0.80

1758066 12x2x1.5 (TPS16-12P) 1.13

1758067 14x2x1.5 (TPS16-14P) 1.24

Fm2XaaHinDiViDUallY & oVerall sHielDeD

instrUmentation Cable

www.summit.com

Page 8: Low Smoke - Summit Electric Supply · PDF fileOur low smoke, zero ... • Tested and approved to IEC standards! This LSZH cable meets IEC standards for flame retardation, smoke densityand

8

BFoU(I) (nek 606 S3/S7)fire resistant instrUmentation anDteleCommUniCation Cable

Cable Structure

Production and Test Standards

Application

- CONDUCTOR:Electrolytic,stranded,tinnedcopperwireIEC60228Class2(Class5onrequest).

- SEPARATOR:Micatapeoverconductor

- INSULATION:HalogenfreeEPRorHalogenfreeHEPR

- LAYUP:Coreslaidupinpairs/triads,pairs/triadslaidupconcentrically.

- DRAIN WIRE:Electrolytic,stranded,tinnedcopperdrainwirealongwitpeverypair/triad

- SCREEN:Electrolyticcopperbackedpolyestertapescreen(100%coverage) overeverypair/triadanddrainwire.

- BEDDING:Halogenfreecompound.

- SCREEN:Electrolytic,tinnedcopperbraidedscreen(90%coverage).

- OUTER SHEATH:SHFMUD

Fixedinstallationcableforsignal,andcommunication.

CONSTRUCTION.................................. NEK606S3/S7,IEC60092/376TESTSANDMATERIAL......................... IEC60092/350-351-359FLAMERETARDATION.......................... IEC60332/1,IEC60332/3CatAFIRERESISTANCE............................... IEC60331HALOGENCONTENT............................ IEC60754/1-2SMOKEDENSITY................................. IEC61034/1-2(DINEN50268/1-2)MUDRESISTANCE............................... IEC60092/359WORKINGTEMPERATURE..................... -40°C/+90°CMIN.BENDINGRADIUS(FIXED)............ 10xOverallDiameterRATEDVOLTAGE................................. 250VTESTVOLTAGE.................................... 1.5kV

1

2

3

4

5

6

7

8

9

Part #Sizes

(mm2)O.D.

(inches)2340970 1x2x0.75 0.46

2340973 2x2x0.75 0.67

2340975 4x2x0.75 0.77

2340972 1x2x1.5 0.51

2462582 2x2x1.5 0.77

2340974 4x2x1.5 0.89

2340976 7x2x1.5 1.05

2462580 12x2x1.5 1.39

1

9

8

7

5

6 23

4

www.summit.com

Page 9: Low Smoke - Summit Electric Supply · PDF fileOur low smoke, zero ... • Tested and approved to IEC standards! This LSZH cable meets IEC standards for flame retardation, smoke densityand

9

BFoU (nek 606 P5/P12)fire resistant, flame retarDant, mUD resistant power Cable

Cable Structure

Production and Test Standards

Application

- CONDUCTOR:Electrolytic,stranded,tinnedcopperwireIEC60228Class2(Class5onrequest).

- SEPARATOR:Micatapeoverconductor

- INSULATION:HalogenfreeEPRorHalogenfreeHEPR

- BEDDING:Halogenfreecompound.

- SCREEN:Electrolytic,tinnedcopperbraidedscreen(90%coverage).

- OUTER SHEATH:SHF2MUD

Usedasfixedinstallationcablesinvariouselectromechanicalandelectronicequipment,emergencyandcriticalsystemsaswellaselectricdistributionandlightingsystems.

CONSTRUCTION.................................. NEK606P5/P12,IEC60092/353TESTSANDMATERIAL......................... IEC60092/350-351-359FLAMERETARDATION.......................... IEC60332/1,IEC60332/3CatAFIRERESISTANCE............................... IEC60331HALOGENCONTENT............................ IEC60754/1-2SMOKEDENSITY................................. IEC61034/1-2(DINEN50268/1-2)MUDRESISTANCE............................... IEC60092/359WORKINGTEMPERATURE..................... -40°C/+90°CMIN.BENDINGRADIUS(FIXED)............ 8xOverallDiameterRATEDVOLTAGE................................. 0.6/1kVTESTVOLTAGE.................................... 3.5kV

1

2

3

4

5

6

Part #Sizes

(mm2)O.D.

(inches)2340960 2x2.5 0.60

2340961 2x4 0.65

2340962 2x6 0.69

2462583 3x1.5 0.59

2340963 3x2.5 0.63

2340964 3x4 0.68

2340965 3x6 0.72

2340966 3x10 0.81

2340967 3x16 0.91

2340968 3x25 1.07

2340969 3x35 1.17

2587543 4x2.5 0.68

2343009 7x1.5 0.74

12

3

45

6

www.summit.com

Page 10: Low Smoke - Summit Electric Supply · PDF fileOur low smoke, zero ... • Tested and approved to IEC standards! This LSZH cable meets IEC standards for flame retardation, smoke densityand

10

m2Xsingle insUlateD ConDUCtor Cable

21

1

2

Cable Structure

Production and Test Standards

Application

- CONDUCTOR:Electrolytic,stranded,annealedcopperwireIEC60228Class5 (Class2and/ortinnedonrequest).

- INSULATION: Lowsmoke,halogenfree,flameretardant,crosslinked,polyolefincompound(HF90). Color:Black(othercolorsavailableonrequest).Doubleinsulationisavailableonrequest.

Usedasfixedinstallationcablesinvariouselectromechanicalandelectronicequipment,includingmarineswitchboards.Usableinallconditionsinmarineenvironment,suchasdry,wetoroilylocations.

CONSTRUCTION.................................. IEC60092/353TESTSANDMATERIAL......................... IEC60092/350-351-359FLAMERETARDATION.......................... IEC60332/1,IEC60332/3CatAHALOGENCONTENT............................ IEC60754/1-2SMOKEDENSITY................................. IEC61034/1-2(DINEN50268/1-2)WORKINGTEMPERATURE..................... -40°C/+90°CMIN.BENDINGRADIUS(FIXED)............ 4xOverallDiameterRATEDVOLTAGE................................. 0.6/1kVTESTVOLTAGE.................................... 3.5kV

Part # Sizes (mm2) Designation O.D. in Inches

* 1x0.50 S-20 0.08

* 1x0.75 S-18 0.09

* 1x1.5 S-16 0.12

* 1x2.5 S-14 0.13

* 1x4 S-12 0.16

* 1x6 S-10 0.18

* 1x10 S-16 0.22

* 1x16 S-26 0.26

1826895 1x25 S-41 0.34

1826896 1x35 S-66 0.39

1826897 1x50 S-106 0.46

1826898 1x70 S-133 0.54

1826899 1x95 S-212 0.60

1826900 1x120 S-250 0.68

* 1x150 S-300 0.76

1859983 1x185 S-400 0.87

* 1x240 S-500 0.98

*NON-STOCK ITEMContactMarineDivision888.326.5174formoredetails.

www.summit.com