Low Pressure, Continuous Flow Breathing Air System
Common Challenges
JOB REQUIREMENTS
CONCERNS
• Supply breathing air to large workforce• Supply breathing air 24 hrs/day• High air usage• Long duration projects• Ease of operation
• Air quality• Tight working area• Hex-Chrome exposure for welders• Breathing air delivery temperature• Back-up compressors and back-up power supply for emergencies
King Air™ - Continuous Flow Breathing Air System
Able to support large crews with Grade D breathing air.
Ideal for projects with large air volume usage.
Its dual-compressor design ensures air supply is not affected due to compressor malfunction.
Equipment design
Chiller/Filter system
Continuous flow compressor
• Dual compressor design which allows compressor switch in the event of a failure.• 250 cfm @125 psi breathing air system• Low pressure alarm.
• Filtration and in-line four-gas monitor ensure grade D breathing air. • Automatic shut off if the gas monitor is triggered.• Chiller reduces air temperature for comfortable breathing.
Equipment design
• Knock out pots• Volume tanks (138gal)• Distribution tanks (11gal)• Low Pressure Manifold• 2” SS Camlock quick
disconnect lines
Key Benefits
• Continuous, cool, clean, high volume air supply.
• Easy to transport, deploy, operate and decommission.
• Emergency backup in the event of compressor failure.
• Eliminates the need for refill or equipment switch, streamlining operations.
• Suitable for large volume requirements and large distances from air supply.
• Versatile to accommodate various applications.
Technical Specifications
Description Technical Specifications
250 cfm breathing air at 125 psl Air Capacity
Filter system and in-line four-gas monitor producing Grade D breathing air Air Quality System
LP alarm and four-gas continuous flow emergency shut off Alarms
Dual compressor provides 100% redundancy for emergency backup. Additional safety backup can be provided by 12 packs or Air Qube™
Back Up
Volume tanks (138gal) and distribution tanks (11gal) Tanks
480 V/3 PH/100 A Service Power Requirements
Low pressure breathing manifold has connections for five personnel, regulator and gauges
Low Pressure Manifold
Designed to operate with doors closed resulting in low noise level (<70 dBa) Noise Level
King Air is fitted in a standard shipping container measuring 20 x 8 ft., mounted on a 30 x 10 ft. Gooseneck trailer making the King Air easy to transport
Measures
Thank you