  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    1/27

    2005 Hewlett-Packard Development Company, L.P.

    The information contained herein is subject to change without notice

    Entry Level Low-end

    Server Refresher VCSession

    Catalog code: 23167

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    2/27

    Description

    This virtual class is covering the latest news regarding the

    non cell based HP9000 and Itanium servers. It is basicallyan Update Session for Volume Servers (A.K.A.

    Information/Knowledge/Sharing) on 2 and 4 socket ZX1-

    based servers and workstations).

    Slides also available from:

    http://wtec.cup.hp.com/~cpuhw/IA64/is-meeting/ipf-is.htm

    http://localhost/var/www/apps/Local%20Settings/Temporary%20Internet%20Files/OLK203/ipf-is.htmhttp://localhost/var/www/apps/Local%20Settings/Temporary%20Internet%20Files/OLK203/ipf-is.htmhttp://localhost/var/www/apps/Local%20Settings/Temporary%20Internet%20Files/OLK203/ipf-is.htmhttp://localhost/var/www/apps/Local%20Settings/Temporary%20Internet%20Files/OLK203/ipf-is.htmhttp://localhost/var/www/apps/Local%20Settings/Temporary%20Internet%20Files/OLK203/ipf-is.htmhttp://localhost/var/www/apps/Local%20Settings/Temporary%20Internet%20Files/OLK203/ipf-is.htm
  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    3/27

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    4/27

    Prerequisites

    Audience

    HP Field Hardware CPU Support Engineers (e.g. CE,

    RCE, ICOE, Escalation Engineers, WW CPU Field

    Specialists).

    Additional Prerequisite Notes

    Students need experience with the low end servers based

    on Itanium and PA-RISC. For example:

    rx16x0, rx26x0, rx4640, rx5670, rp34x0, rp44x0

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    5/27

    WTEC Charter

    Worldwide Technology Expert Center is part of Global

    Solutions Engineering (GSE) under Mark Sullivan. WTECprovides Level 3 technical support to WW Customer

    Support field organizations and other HP Services

    groups, and delivers expert level 24*7 support to HP's

    Mission Critical customers. WTEC works proactively onquality and supportability initiatives and on the

    development of supportability and troubleshooting tools.

    The CPU hardware team supports the systems included

    in this training session.

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    6/27

    WTECs Support and Current Issues webpages

    WTECs web pages can be found at:

    http://wtec.cup.hp.com

    CPU Server Hardware Team at:

    http://wtec.cup.hp.com/~cpuhw/

    Current Issuesare a very important part of our distribution

    of information on the issues we are getting calls. The

    NEWCurrent Issues server can be found at:

    http://15.13.122.166/enter_password.phpPlease register using your SEA emailand NT\Domain Account

    password

    http://localhost/var/www/apps/http://localhost/var/www/apps/Local%20Settings/http://15.13.122.166/enter_password.phphttp://15.13.122.166/enter_password.phphttp://localhost/var/www/apps/Local%20Settings/http://localhost/var/www/apps/
  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    7/27

    WTECs Support and Current Issues webpages

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    8/27

    Latest News and Current Issues

    Issues with IA64 systems

    Use USB memory s t ick to upgrade f i rmware

    Copy the EFI firmware utilities to the memory stick with

    your PC

    From EFI shell:

    Shell> maprfs

    Shell> fsX:

    fsX:> fwupdate.efi

    Only works for IA servers

    Get this document:http://wtec.cup.hp.com/~cpuhw/IA64/cookbook/USB_flash_EFI.pdf

    http://wtec.cup.hp.com/~cpuhw/IA64/cookbook/USB_flash_EFI.pdfhttp://wtec.cup.hp.com/~cpuhw/IA64/cookbook/USB_flash_EFI.pdf
  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    9/27

    Latest News and Current Issues

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    10/27

    Latest News and Current Issues

    Issues common to both IA64 and PA systems

    Red fault LED on midd le diskof rx 2600 & rp34x0 Workaround instructions to correct illumination of red

    LED on internal disk drive(s) for rp3440, rp3410, andrx2600 servers

    The purpose of this document is to show a simple process toeliminate the unwanted red LED condition on the disk drive(s)from coming on during a startup or when the system isoperating normally. This red LED indication on the disk drive isdue to contact between the middle plastic tip of the hard driverail guide and the activity LED.

    To repair the contact problem, the center plastic tip must beremoved from the end of the hard drive rail guide. By removingthe plastic tip, current will no longer flow across their surface toenable the LED to illuminate red.

    Note: This will not damage the function of the hard drive.

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    11/27

    Latest News and Current Issues

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    12/27

    Latest News and Current Issues

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    13/27

    Latest News and Current Issues

    Issues common to both IA64 and PA systems

    continued

    Red fault LED on midd le diskof rx 2600 & rp34x0

    continued

    Future new and replacement disk mech. parts will not

    have the center plastic tip.

    Future disk backplane will have green LED rather than the

    current green/red LED.

    Get this document:

    http://wtec.cup.hp.com/~cpuhw/IA64/rx2600_X-Peak/peak_disk_led_fix.pdf

    http://wtec.cup.hp.com/~cpuhw/IA64/rx2600_X-Peak/peak_disk_led_fix.pdfhttp://wtec.cup.hp.com/~cpuhw/IA64/rx2600_X-Peak/peak_disk_led_fix.pdfhttp://wtec.cup.hp.com/~cpuhw/IA64/rx2600_X-Peak/peak_disk_led_fix.pdfhttp://wtec.cup.hp.com/~cpuhw/IA64/rx2600_X-Peak/peak_disk_led_fix.pdf
  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    14/27

    Latest News and Current Issues

    Issues common to both IA64 and PA systems

    Flashing REDfault LED

    Affects rx2600/rx4640/rp34x0/rp4440

    Caused by a combination of BMC and MP f/w issues

    Workarounds available to clear the LED include

    MP:CM>RB to reset the BMC

    Power cycle the server

    F/W release for IPF BMC 3.47, MP E.03.13

    F/W release for PA will be with Mako64 intro.

    PDC 45.11 BMC 03.49 for rp44x0

    PDC 45.11 BMC 03.50 for rp34x0

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    15/27

    Latest News and Current Issues

    Issues common to both IA64 and PA systems

    Smart Array SA640x firmware

    False battery warning fixed with 2.34 fw

    Updating fw

    IPF use offline EFI saupdate.efi

    PAuse online SAUTIL (note warnings)

    Available through www.hp.com support & drivers web pages

    http://wtec.cup.hp.com/~cpuhw/storage/storage.htm

    Refer to Service Note A9890A-01

    Defective returns requested sent CATCH 3 when in BCS

    serversDELETED

    Refer to Current ISSUE 1667 for details

    http://localhost/var/www/apps/conversion/storage/storage.htmhttp://localhost/var/www/apps/conversion/storage/storage.htm
  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    16/27

    Latest News and Current Issuescont.

    MSA 30 & A7173A u320 Dual SCSI PCI Issues

    SCSI resets and timeout reported in syslog/dmesg

    Other useful IO and Mass Storage information is available

    at: http://wtec.cup.hp.com/~cpuhw/storage/storage.htm

    Recently added:SCSI Solutions WhitePaperHP-UX

    HP Smart Array PCI card "Survival Guide(compiled by JimMcCarter)

    SCSI Ultra320 HP-UX Software Releases(how to determine

    the correct driver is installed)

    http://localhost/var/www/apps/conversion/storage/storage.htmhttp://localhost/var/www/apps/conversion/storage/ScsiSolutionsWhitePaper.pdfhttp://localhost/var/www/apps/conversion/storage/ScsiSolutionsWhitePaper.pdfhttp://localhost/var/www/apps/conversion/storage/ScsiSolutionsWhitePaper.pdfhttp://localhost/var/www/apps/conversion/storage/smart_array/HP_Smart_Array_survival_guide_rev2.docmailto:[email protected]:[email protected]://scsi.cup.hp.com/ULTRA_320/software_releases.htmlhttp://scsi.cup.hp.com/ULTRA_320/software_releases.htmlhttp://scsi.cup.hp.com/ULTRA_320/software_releases.htmlhttp://scsi.cup.hp.com/ULTRA_320/software_releases.htmlmailto:[email protected]:[email protected]://localhost/var/www/apps/conversion/storage/smart_array/HP_Smart_Array_survival_guide_rev2.dochttp://localhost/var/www/apps/conversion/storage/ScsiSolutionsWhitePaper.pdfhttp://localhost/var/www/apps/conversion/storage/ScsiSolutionsWhitePaper.pdfhttp://localhost/var/www/apps/conversion/storage/ScsiSolutionsWhitePaper.pdfhttp://localhost/var/www/apps/conversion/storage/ScsiSolutionsWhitePaper.pdfhttp://localhost/var/www/apps/conversion/storage/ScsiSolutionsWhitePaper.pdfhttp://localhost/var/www/apps/conversion/storage/ScsiSolutionsWhitePaper.pdfhttp://localhost/var/www/apps/conversion/storage/storage.htm
  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    17/27

    Latest News and Current Issues

    Issues common to both IA64 and PA systems

    Sett ing rx4640/rp44x0 dip sw itches

    I/O Baseboard and CPU carrier FRUs have critical

    switches needing to be checked/set if FRU replaced.

    IPF vs. PA-RISC switch on CPU Carrier Board

    MX2 vs. Itanium2 switch on I/O Baseboard

    Core VGA enable switch on I/O Baseboard

    Proper DIP switch settings documented here:

    http://wtec.cup.hp.com/~cpuhw/IA64/rx4640_Diablo/switches-

    Diablo_Hamilton.pdf

    http://wtec.cup.hp.com/~cpuhw/IA64/rx4640_Diablo/switches-Diablo_Hamilton.pdfhttp://wtec.cup.hp.com/~cpuhw/IA64/rx4640_Diablo/switches-Diablo_Hamilton.pdfhttp://wtec.cup.hp.com/~cpuhw/IA64/rx4640_Diablo/switches-Diablo_Hamilton.pdfhttp://wtec.cup.hp.com/~cpuhw/IA64/rx4640_Diablo/switches-Diablo_Hamilton.pdfhttp://wtec.cup.hp.com/~cpuhw/IA64/rx4640_Diablo/switches-Diablo_Hamilton.pdf
  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    18/27

    RP44x0/rx4640 Dip Switch Settings

    I/O Baseboard Switch Settings

    Remove

    Fan#1(m

    iddle)

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    19/27

    RP44x0/rx4640 Dip Switch Settings

    CPU Carrier Switch Settings

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    20/27

    Latest News and Current Issues

    Issues common to both IA64 and PA systems

    Pathing Spreadsheets for xz1 Systems

    Useful for correlating different Paths (i.e. ACPI vs. HP-UX vs.

    Linux, etc.)

    Useful for correlating physical IO devices to Paths

    Useful for correlating Paths to IO hardware (e.g. Rope number) Block Diagrams for each system

    Physical System Views

    Available at this URL:

    http://wtec.cup.hp.com/~cpuhw/IA64/pathing/system_paths.htm Processor Identi f icat ion Spreadsheet

    http://wtec.cup.hp.com/~cpuhw/IA64/Processor_Identifier.xls

    (listed under each Product web page)

    http://wtec.cup.hp.com/~cpuhw/IA64/pathing/system_paths.htmhttp://localhost/var/www/apps/conversion/tmp/Processor_Identifier.xlshttp://localhost/var/www/apps/conversion/tmp/Processor_Identifier.xlshttp://wtec.cup.hp.com/~cpuhw/IA64/pathing/system_paths.htm
  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    21/27

    Latest News and Current Issues

    Issues with PA systems

    Troubleshoo t ing memory problems Rotate DIMMs within a quad when only one DIMM is

    deconfigured (should be rare).

    Replace and Rotate DIMMs within a quad when an entirequad is deconfigured due to a DIMM failure.

    Refer to WTEC Current Issues article #1621 for details. For PDC 45.11 or greater, BCH Clear PDT command has been

    enhanced to avoid rotating DIMMs if PDT cleared immediatelybefore replacing defective memory DIMM.

    How to Replace and Rotate DIMMs (assuming DIMM 4b is

    defective and caused rank 4 to be deconfigured:

    1. Replace DIMM 4b

    2. Rotate DIMMs 4a->5a->5b->4a

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    22/27

    Latest News and Current Issues

    Issues with PA systems

    PDC updates current ly o nly formally p rovided in HP-UXpatch form

    EML will provide ISO images in the future

    WTEC currently provides ISO images at:

    http://wtec.cup.hp.com/~cpuhw/hppa/rp34x0/rp3440_firmware.htm

    http://wtec.cup.hp.com/~cpuhw/hppa/rp4440/rp4440_firmware.htm

    MP f/w available via HP-UX patch or via FTP

    iLO functionality available in MP E.03.xx firmware

    Connect with browser using the MPs IP address Sim i lar to iLO on other system p lat forms

    MP firmware patches:PHSS_33042: s700_800 11.11 rp4440/rp3440/rp3410 iLO MP E.03.13 FW Patch

    PHSS_33043: s700_800 11.23 rp4440/rp3440/rp3410 iLO MP E.03.13 FW Patch

    http://wtec.cup.hp.com/~cpuhw/hppa/rp34x0/rp3440_firmware.htmhttp://wtec.cup.hp.com/~cpuhw/hppa/rp4440/rp4440_firmware.htmhttp://wtec.cup.hp.com/~cpuhw/hppa/rp4440/rp4440_firmware.htmhttp://wtec.cup.hp.com/~cpuhw/hppa/rp34x0/rp3440_firmware.htm
  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    23/27

    Newly Released Systems and Updates toExisting Systems

    IA64 systems

    The new Madison 9M (Mad9M) pro cessors

    Mad9M A1 vs. A2 stepping considerations

    Onyx rx1620

    SFW 2.18 minimum to support A2 stepping

    Badger Peak rx2620

    SFW 3.17 minimum to support A2 stepping

    rx4640 products AB530A, etc.

    SFW 3.11 minimum to support Mad9M processors

    SFW 3.17 minimum to support A2 stepping

    For rx4640 with Mad9M processors, use replacement I/O

    baseboard part# A6961-69401

    N l R l d S d U d

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    24/27

    Newly Released Systems and Updates toExisting Systems

    PA systems

    MAKO64 to be released ~ 4/29/2005

    Enhanced p rocesso r (PA8900)

    64MB L2 cache

    Cannot mix MAKO32 and MAKO64 processors on same

    system/cell

    Can upgrade existing rp34x0 and rp44x0 systems to

    MAKO64 processors

    New PDC 45.11

    Available via HP-UX patches early June 2005PHSS_33086 - rp34x0 HP-UX 11i v1 (PDC 4511/BMC 03.50/iLO E.03.15)PHSS_33087 - rp34x0 HP-UX 11i v2 (PDC 4511/BMC 03.50/iLO E.03.15)PHSS_33088 - rp44x0 HP-UX 11i v1 (PDC 4511/BMC 03.49/iLO E.03.15)PHSS_33089 - rp44x0 HP-UX 11i v2 (PDC 4511/BMC 03.49/iLO E.03.15)

    PDC 45.11 on I/O Baseboard part# A6961-69401

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    25/27

    Miscellaneous other issues

    rp4440/rx4640

    VRMs on I/O Baseboard are NOTindiv idual lyreplaceable

    rx5670

    False memory MBE MCA caused by memory carr ier

    See Current Issues #1703 for details

    All servers

    Power problems caused by a shor t c i rcu i t

    Cycling power can cause additional damage

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    26/27

    Questions or issues you want to discuss

    Are there any field issues affecting serviceability to

    report?

    Are there any observed CPU H/W problems to report?

    Are there any documentation issues to report?

  • 8/10/2019 Low-End Server Refresher VC Session-08152005

    27/27

    Questions or issues you want to discuss

    Is there anything we have not covered here?