25
Design, Fabrication & Supply of Materials: LORONG K, TELUK KURAU 4 STOREY STRATA-TITLE APARTMENT WITH LIFT & SWIMMING POOL At Lorong K, Teluk Kurau, Singapore

LORONG K, TELUK KURAU 4 STOREY STRATA-TITLE … fileFABRICATION WORKS QA/QC CHECK BY SETSCO HOT DIPPED GALVANIZING PACKING & LOADING. W&A PRE-ENGINEERED STEEL INSTALLATION Column Connection

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Design, Fabrication & Supply of Materials:

LORONG K, TELUK KURAU

4 STOREY STRATA-TITLE

APARTMENT

WITH LIFT & SWIMMING POOL

At Lorong K, Teluk Kurau, Singapore

CONTENT

PROJECT INFORMATION 2

W&A BUILDING SYSTEM INTRODUCTION 3

W&A PRE-ENGINEERED STEEL Design and Specifications 4-6Fabrication 7Installation 8-10

W&A FLOORING SYSTEM 11

W&A ALC WALL SYSTEM Application 12-15Details and Connection 16Panel Configuration 17-18

COMPLETION PHOTOSExternal Façade 19-22Internal Finishing 23-24

PROJECT INFORMATION

1. Project location: Lor K Telok KurauSingapore;

2. Building application: Apartment;

3. Build up area: 3157 M2;

4. NO of storey: 4 storey + 1 Basement

5. Building system: - Steel structure - Metal decking floor - ALC wall - Metal roof

6. Estimated Schedule: 14 month

W&A BUILDING SYSTEM

INTRODUCTION

Double layer metal sheet

roof

system (M-Snap)

ALC Wall Panel

Besta Board Fins

Metal Deck with RC Slab

Pre-engineered Steel

Structure, Q345B, HDG

Aluminium Frame Curtain

Wall

W&A PRE-ENGINEERED STEEL

DESIGN & SPECIFICATIONS

A.Building Regulation & Design Code

Building Control Regulation (1989)BS 6399: Part 1: 1996 Design Loading for Buildings SS CP65: Part 1: 1999 Structural Use of ConcreteBS 5950: Part 1: 2000 Structural Use of Steelwork in BuildingsBC 1: 2012 Design Guide on Use of Alternative Steel Materials to BS5950CP3 : 1972 Basic Data for the Design of Building

B.Design Loading

(Live Load)Second Storey 1.5KN/m2Third Storey 1.5KN/m2Attic Storey 1.5KN/m2Roof Storey 0.5KN/m2Roof ( equipment area ) 7.5KN/m2

(Dead Load)Second Storey 4.2KN/㎡Third Storey 4.2KN/㎡Attic Storey 4.2KN/㎡Roof Storey 0.5KN/㎡Wind Load 0.33 kN/㎡

W&A PRE-ENGINEERED STEEL

DESIGN & SPECIFICATIONS

Structure Design And Calculation By Midas Gen

W&A PRE-ENGINEERED STEEL

DESIGN & SPECIFICATIONS

Shop Drawing Design By Tekla Structure

Roof Structure &

Lift Shaft

Column & Beam

Connection

W&A PRE-ENGINEERED STEEL

FABRICATION

FABRICATION WORKS QA/QC CHECK BY

SETSCO

HOT DIPPED GALVANIZING PACKING & LOADING

W&A PRE-ENGINEERED STEEL

INSTALLATION

Column Connection

to Ground Beam

Tapered Column to

reduce steel weight

140mm wide column

designed to requirement

Bolt & Nut Connection

No Welding on

Structure

W&A PRE-ENGINEERED STEEL

INSTALLATION

Pre-rolled Curve Roof

Beam

Pre-fab Steel Staircase Steel Lift Shaft

W&A METAL DECKING FLOOR SYSTEMW&A METAL DECK

• We provide layout for every pieceof metal deck

• This is to illustrate on how deckingis installed and integrated with oursteel structure

• W&A design and supply decking,shear studs and end capping

• W&A also include design of the reinforced concrete slab thickness

• Metal deck designed as non-composite to eliminate the requirement of fire proofing at slab soffit

W&A ALC WALL PANEL SYSTEM

Dry Density = 550- 650 Kg/m3

Compressive Strength > 4.0 Mpa

Heat Conductivity Coefficient < 0.13

W/m.k

Dry Shrinkage < 0.13mm/m

Single Point Hanging Force = 1200N

AL

C P

an

el P

erf

orm

an

ce

W&A ALC WALL PANEL

APPLICATION

ALC Panel used at EXTERNAL WALL

ALC Panel used at CAVITY PARTITION WALL- 75mm ALC + 28mm air gap + 75mm ALC- Acoustic Property at 52dB- Ease of installation M&E Conduit

ALC Panel used at CURVE WALL

- Easily cut and suit forcurve walls

- No special tools are needed

W&A ALC WALL PANEL APPLICATION

W&A ALC WALL PANEL APPLICATION

Partition Wall 75mm ALC 2 layers

Internal Wall75mm & 100mm ALC

External Wall125mm ALC

ALC FINISHING with Skim Coat Only

NO PLASTERING

W&A ALC WALL PANEL TYPICAL DETAILS &

CONNECTION

W&A ALC WALL PANEL

CONFIGURATIONW&A WALL PANEL

LAYOUT

• We provide layout for everypiece of ALC panel

• This is to illustrate on how ALCpanel are installed andintegrated with our steelstructure

• In-house designer tocommunicate with client’srepresentative to resolvequeries and provide technicalsupport

• Wall Panel layout designed using Tekla Software

W&A ALC WALL PANEL CONFIGURATION

W&A WALL PANEL LAYOUT

• Length of individual panelprovided for ease of installation

• Cut list provided for ease ofcutting

• Layout drawings are providedfor every wall

• Ease of identification of individual panel

PROJECT COMPLETION – EXTERNAL FACADE

PROJECT COMPLETION – EXTERNAL FACADE Glass Balustrade Laminated

Tempered Glass

ALC Parapet Wall

M-Snap Metal Roof

ALC Wall Panel

Double Glazed Laminated

Aluminium Window

MS Railing

PROJECT COMPLETION – EXTERNAL FACADE

PROJECT COMPLETION – EXTERNAL FACADE

DURING

CONSTRUCTIONDURING

COMPLETION

PROJECT COMPLETION – EXTERNAL FACADE

INTERIOR FINISHING

• ALC Wall Panel – Skim Coat and Paint

• Gypsum Board Ceiling

• WPC Extruded Door c/w Door Frame

• Steel Staircase with Stainless steel laminated glass balustrade

• Aluminium Window Frame with Double Laminated Glazing

PROJECT COMPLETION – STAIRCASE FINISHING

Thank you for your time and attention

- Well & Able Group of Companies

Singapore HQ: Shanghai Office:

No.23, Genting Road #03-01, Level 2&3, Building 12, 1818 Lianhang Road,

Chevalier House Singapore 349481 Minhang District Shanghai 20112

T: +65-65471329 Tel: +86-021-34780561

Malaysia Office: Maldives Office: