Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
SHEET NUMBER:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
INITIAL ISSUE DATE:
JOB NUMBER:
C-1
200124
9/16/2020
RG/DC
JK
JK
N/A
GSWCC LEVEL II CERTIFICATION NO. 31908
EXPIRES: 01/22/2022
0
9
-
1
6
-
2
0
2
0
FO
R
LO
NG
VIE
W R
UN
LA
ND
L
OT
9
&
2
4 ~
1
6T
H D
IS
TR
IC
T
DE
KA
LB
C
OU
NT
Y, G
EO
RG
IA
SCALE:
WATTS & BROWNING ENGINEERS, INC. HAS EXAMINED THE NATIONAL FLOOD
INSURANCE PROGRAM (NFIP) FLOOD INSURANCE RATE MAP (FIRM) AND BY
GRAPHICALLY PLOTTING THE LOCATION OF THE SUBJECT PROPERTY ONTO DEKALB
COUNTY FIRM MAP NUMBER 13089C0158J, DATED MAY 16, 2013, THE REFERENCED
PROPERTY IS LOCATED IN THE ZONES LISTED BELOW:
ZONE AE: BASE FLOOD ELEVATIONS DETERMINED.
ZONE X (UNSHADED): AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE
FLOODPLAIN.
SITE
LOCATION MAP
N.T.S.
FLOOD MAP
N.T.S.
SITE
OWNER
STB LOTS, LLC
5755 DUPREE DR NW #130
ATLANTA, GA 30327-4352
DEVELOPER (PRIMARY PERMITTEE):
VENTURE COMMUNITIES, LLC
5500 INTERSTATE NORTH PKWY
SUITE 150
SANDY SPRINGS, GA 30328
PHONE: (770) 616-7515
24 HOUR EMERGENCY CONTACT:
BOB WHITE (770) 616-7515
ENGINEER:
WATTS & BROWNING ENGINEERS, INC.
1349 OLD 41 HWY NW, SUITE #225
MARIETTA, GA 30060
PHONE: (678) 324-6192
FAX: (770) 694-6870
CONTACT: DARYL COOK
NOTE: ABOVE GROUND UTILITY LOCATIONS WERE OBTAINED FROM FIELD OBSERVATIONS BY
OTHERS. WATTS & BROWNING ENGINEERS HAS NOT RESEARCHED UNDERGROUND UTILITY
LOCATIONS. INFORMATION SHOWN HEREON REGARDING THE EXISTENCE, SIZE, TYPE AND
LOCATION OF UNDERGROUND UTILITIES IS BASED ON MARKINGS IN THE FIELD AND INFORMATION
FURNISHED TO US BY OTHERS AND WATTS & BROWNING ENGINEERS IS UNABLE TO CERTIFY TO
THE ACCURACY OR COMPLETENESS OF THIS INFORMATION. INDICATED LOCATIONS SHOULD BE
CONFIRMED IN THE FIELD WITH THE UTILITY COMPANIES PRIOR TO PROCEEDING WITH
PLANNING, DESIGN OR CONSTRUCTION.
AP#1244268 - SKETCH PLAT
FOR
LONGVIEW RUN
LOCATED IN
LAND LOTS 9 & 24
16TH DISTRICT
DEKALB COUNTY, GEORGIA
ADDRESSES: 2620 SHELL BARK ROAD
PARCEL ID: 16 009 01 001 &
2641 ACUITY WAY
PARCEL ID: 16 024 06 001
SITE
GENERAL NOTES:
1. THE TOPOGRAPHIC AND ELEVATION DATA SHOWN HERON WAS OBTAINED FROM
BOUNDARY & TOPOGRAPHIC INFORMATION FROM A SURVEY FOR VENTURE
COMMUNITIES, LLC BY NORTH POINT LAND SURVEYING, DATED APRIL 22, 2020 AND IS
NOT CERTIFIED AS CORRECT BY THE ENGINEER. USERS OF THIS DATA DO SO AT THEIR
OWN RISK.
2. NO HISTORIC FEATURES HAVE BEEN FOUND ONSITE. CONTOUR INTERVAL IS 1', BASED
ON NAD83 DATUM.
3. THE DEVELOPED SITE WILL CONSIST OF 38 TOWN HOMES.
4. KNOWN SANITARY SEWER AND WATERMAIN LINES AND EASEMENTS ARE SHOWN.
5. NO WETLANDS EXIST OUTSIDE OF THE FLOOD PLAIN OR WITHIN THE PROPOSED LIMITS
OF DISTURBANCE, TO THE BEST OF OUR KNOWLEDGE.
6. SNAPFINGER CREEK TRIBUTARY 3 IS THE RECEIVING WATERS.
7. NO BURY PITS ARE KNOWN TO EXIST OR ARE PROPOSED.
8. ROADWAYS WILL BE 24' BC/BC & PUBLIC W/ 55' ROW, CONSTRUCTED TO DEKALB
COUNTY STANDARDS.
9. WATER & FIRE SERVICES WILL BE PUBLICLY MAINTAINED BY DEKALB COUNTY, VIA
EASEMENTS.
10. ELECTRIC SERVICE WILL BE UNDERGROUND AND PROVIDED BY GEORGIA POWER.
11. SANITARY SEWER & WATER SERVICES WILL BE PROVIDED BY DEKALB COUNTY. NO
SEPTIC TANKS EXIST ONSITE OR ARE PROPOSED.
12. A 75' TRIBUTARY BUFFER MEASURED FROM THE POINT OF WRESTED VEGETATION,
WILL BE MAINTAINED ON ALL STATE WATERS THAT ARE NOT APPROVED FOR A BUFFER
ENCROACHMENT VARIANCE BY DEKALB COUNTY OR GA. E.P.D.
13. SKETCH PLAT APPROVAL DOES NOT CONSTITUTE APPROVAL OF THE STORM DRAINAGE
OR SANITARY SEWER SYSTEMS. NO CONSTRUCTION SHALL BEGIN UNTIL
CONSTRUCTION PLANS ARE APPROVED AND A DEVELOPMENT PERMIT IS OBTAINED.
14. THE OWNER OF THE PROPERTY IS RESPONSIBLE FOR COMPLIANCE WITH THE CORPS
OF ENGINEERS REQUIREMENTS REGARDING WETLANDS.
15. A MANDATORY HOME OWNERS ASSOCIATION IS REQUIRED FOR MAINTENANCE OF
ACCESS DRIVES, UTILITIES, AND STORM MANAGEMENT FACILITIES WITHIN COMMON
AREAS AND TO PROVIDE A DECLARATION OF PROTECTIVE COVENANTS AND
CONDITIONS ADDRESSING MAINTENANCE RESPONSIBILITY.
16. MOST OF THE PROPOSED DISTURBED AREA FALLS WITHIN EXISTING DISTURBED
AREAS. THERE ARE NO SPECIMEN TREES LOCATED WITHIN THE PROPOSED AREAS OF
DISTURBANCE. MU-4 PRESERVATION REQUIREMENTS WILL BE MET.
17. ALL UNITS TO BE INDIVIDUALLY METERED (WATER).
18. DEKALB COUNTY SANITATION DEPARTMENT WILL BE RESPONSIBLE FOR HANDLING
HOUSEHOLD WASTE, YARD DEBRIS AND RECYCLABLE MATERIAL.
19. 72 HOURS NOTICE IS REQUIRED TO GEORGIA 811 UTILITY PROTECTION CENTER
BEFORE ANY PLANNED DIGGING, http://www.georgia811.com
20. DEKALB COUNTY IS NOT RESPONSIBLE FOR ANY ERRORS OR OMISSIONS BY
ENGINEERS OR OTHER DESIGN PROFESSIONALS ON DESIGN OR COUNTY CODE
REQUIREMENTS FOR THIS PROJECT.
21. THIS SITE WAS A FUTURE PHASE OF LONGVIEW POINTE SUBDIVISION.
22. NO KNOWN PERMITS ARE ACTIVE FOR THIS SITE.
23. NO STREET PARKING SHALL BE ALLOWED, AND SIGNAGE SHALL BE POSTED.
24. IF THE ROAD WIDTHS ARE LESS THAN 26' WITH BUILDING HEIGHTS EXCEEDING 35 FEET,
THEN THE BUILDING SHALL INCLUDE FIRE SPRINKLER SYSTEMS. NFPA 13D ARE
ACCEPTABLE
25. UNIT 28 TRASH CART TO BE PLACED NEAR UNITS 27/26 FOR PICKUP
26. WATERSHED NOTES: ALL 6” SS LATS & 8” SS MAIN WITHIN ROW TO BE DIP, PLACE PVC
CO 1’ INSIDE ROW, NO BLDG AND/OR PATIOS IN SSE, PLACE WATER MAIN 3’ BEHIND
CURB, WATER SERVICE MAY BE 1” & SPLIT INTO 2 ¾”, PLACE METER BOXES BETWEEN
SIDEWALK & BOC OR BETWEEN SIDEWALK & EXTEND MAIN FROM ROAD C TO ‘LOOP’ &
CONNECT TO MAIN IN ACUITY WAY
27. ROW WILL BE DEDICATED TO PROVIDE 1' BEHIND THE EXISTING SIDEWALK ON ACUITY
WAY NEAR PANOLA IND TO ALLOW FOR STREET LIGHT PLACEMENT
28. A STORM WATER BMP IS PROPOSED AND WILL BE DESIGNED DURING LDP PERMITTING.
29. PERVIOUS PAVERS PLACED IN THE FLOOD PLAIN SHALL NOT REDUCE THE FLOOD PLAIN
VOLUME/CAPACITY.
SOILS LEGEND
Ca CARTECAY SILT LOAM, FREQUENTLY FLOODED0.6"-2"/HOUR
PERMIBILITY
0.6"-2"/HOUR
HsB HIWASSEE SANDY LOAM, 2 TO 6 PERCENT SLOPES0.6"-2"/HOUR
CvF CHESTATEE STONY SANDY LOAM, 15 TO 45 PERCENT SLOPES
0.6"-2"/HOUR
PfC PACOLET SANDY LOAM, 2 TO 10 PERCENT SLOPES0.6"-2"/HOUR
HtC2 HIWASSEE CLAY LOAM, 6 TO 10 PERCENT SLOPES, ERODED
THIS SKETCH PLAT HAS BEEN SUBMITTED TO AND APPROVED BY THE PLANNING
COMMISSION OF DEKALB COUNTY,
ON THIS . DAY OF . 20 .
BY: . DIRECTOR
PLANNING COMMISION CHAIRMAN
DEKALB COUNTY, GEORGIA.
SK
ET
CH
P
LA
T - C
OV
ER
S
HE
ET
DEVELOPMENT DATA
TOTAL SITE AREA: 6.20 AC
CURRENT ZONING: MU-4
PROPOSED UNITS: 38 UNITS
PROPOSED DENSITY: 6.13 UNITS/AC
REQUIRED OPEN SPACE: 20% (1.4 AC)
PROPOSED OPEN SPACE: 51% (3.6 AC)
MAXIMUM LOT COVERAGE: 90%
MINIMUM DWELLING UNIT SIZE: 850 SF
MAXIMUM BUILDING HEIGHT: 45' OR 3 STORIES
(WHICHEVER IS LESS)
MINIMUM LOT WIDTH: 20'
GUEST PARKING: 13 SPACES
SETBACKS:
FRONT: 15'
REAR: 10'
SIDE: 0'
SIDE CORNER: 5'
DEVELOPMENT OF RESIDENTIAL TOWNHOMES. PROJECT IS
LOCATES AT 2641 ACUITY WAY/2620 SHELL BARK ROAD.
SITE IS 6.2 ACRES AND WILL HAVE 38 UNITS.
COMBINATION PLAT AP#67987986 (PERMIT#1ED 244433)
THE AMENITY AREA IS EXISTING AND IS FULLY
OPERATIONAL.
1
2
-
0
1
-
2
0
Sheet List Table
Sheet Number Sheet Title
C-1 SKETCH PLAT - COVER SHEET
C-2 SKETCH PLAT - SITE PLAN
Z-1 ZONING MINUTES
TS-1 TREE SURVEY (BY OTHERS)
\\hercules\E
ngineering D
ata\E
NG
R\200124\dw
g\200124-C
OV
ER
-D
ET
AILS
.dw
g, 12/1/2020 12:14:33 P
M, _A
utoC
AD
P
DF
(G
eneral D
ocum
entation).pc3
AutoCAD SHX TextNO. DATE BY DESCRIPTION
AutoCAD SHX TextREVISIONS
AutoCAD SHX TextWATTS & BROWNING ENGINEERS, INC.
AutoCAD SHX TextCIVIL ENGINEERS & LAND SURVEYORS
AutoCAD SHX TextWWW.WBENGR.COM
AutoCAD SHX TextFAX: (770) 694-6870
AutoCAD SHX TextPHONE:(678) 324-6192
AutoCAD SHX Text1349 OLD 41 HWY NW, SUITE #225
AutoCAD SHX TextMARIETTA, GEORGIA 30060
AutoCAD SHX TextLSF000429 - PEF000714
AutoCAD SHX TextCIVIL ENGINEERS & LAND SURVEYORS
AutoCAD SHX TextWATTS & BROWNING ENGINEERS, INC.
AutoCAD SHX Text1 09-16-20 JK SKETCH PLAT
AutoCAD SHX Text2 12-01-20 RTG ADDRESS SKETCH PLAT COMMENTS
A
C
U
IT
Y
W
A
Y
6
0
' R
/W
P
A
N
O
L
A
I
N
D
U
S
T
R
I
A
L
B
L
V
D
6
0
'
R
/
W
L
O
N
G
V
I
E
W
R
U
N
6
0
'
R
/
W
R
2
8
'
R
2
8
'
2
0
'
PERVIOUS
PEDESTRIAN TRAIL
100 Y
R
F
LO
O
D
EL=
836.7
1
0
0
Y
R
F
L
O
O
D
E
L
=
8
3
6
.4
1
0
0
Y
R
F
L
O
O
D
E
L
=
8
3
6
.3
M
A
IL
K
IO
S
K
INV=826.94
INV=827.86
INV=826.84
INV=826.77
INV=827.76
INV=827.79
INV=827.67
CB
TOP=838.39
INV=832.09
CB
TOP=838.64
INV IN=831.26
INV OUT=826.94
SSMH
TOP=834.83
INV IN=820.23
INV IN=821.63
INV OUT=820.13
SSMH
TOP=833.67
INV IN=819.97
INV OUT=819.87
SSMH
TOP=835.86
INV IN=819.31
INV OUT=818.86
SSMH
TOP=835.47
INV IN=819.37
INV IN=820.22
INV IN=823.77
INV OUT=819.17
SSMH
TOP=843.84
INV IN=823.39
INV OUT=823.34
SSMH
TOP=853.29
INV =827.13
SSMH
TOP=863.94
INV IN=845.64
INV OUT=845.64
N/F
STB LOTS LLC
DB 22412/PG 262
ZONED: MU-4
N/F
STB LOTS LLC
DB 22412/PG 262
ZONED: MU-4
N/F
LONGVIEW COMMUNITY
ASSOCIATION, INC.
DB 20983/PG 32
PB 190/PG 47
ZONED: MU-4
INV=822.86
INV=836.62
INV=838.57
JB
TOP=858.48
INV IN=846.53
INV OUT=846.43
CB
TOP=857.72
INV IN=849.62
INV OUT=847.24
CB
TOP=858.67
INV IN=851.87
INV IN-851.57
INV OUT=850.52
SM
H
S
M
H
SM
H
S
M
H
SM
H
S
M
H
S
M
H
8
"
D
IP
8
"
D
IP
8
"
D
I
P
8
"
D
I
P
8" D
IP
8
"
D
I
P
APPROXIMATE LOCATION
EXISTING 8" DIP WATERMAIN
(LOCATION TO BE VERIFIED IN
THE FIELD)
2
4
'
B
C
-
B
C
2
4
' B
C
-
B
C
24' B
C-B
C
G
U
E
S
T
P
A
R
K
IN
G
(
2
-
P
A
R
A
L
L
E
L
)
G
U
E
S
T
P
A
R
K
IN
G(
5
-
S
L
O
T
)
G
U
E
S
T
P
A
R
K
I
N
G
(
2
-
P
A
R
A
L
L
E
L
)GUEST PARKING
(4-SLOT)
OC
S
JB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
PfC
CvF
Ca
HtC2
HsB
8
5
4
8
5
4
8
5
2
8
5
0
8
5
2
8
5
2
8
5
4
8
5
2
8
5
0
8
4
4
8
5
0
8
4
8
8
5
0
8
4
68
4
7
8
5
3
856
8
5
8
8
5
4
8
5
4
8
5
4
8
5
5
8
5
2
854
8
4
8
8
4
8
852
8
5
2
8
5
2
8
5
0
8
5
0
8
4
6
8
4
2
8
5
0
PI
P
I
J
B
P
R
O
P
O
S
E
D
R
O
W
5' SIDEWALK
5' SIDEWALK
5' BEAUTY STRIP
5' BEAUTY STRIP
6" CHAIN
LINK FENCE
W/ 12' GATE
E
X
R
O
W
APPROXIMATE LOCATION EX WATERMAIN
5
'
S
I
D
E
W
A
L
K
5
' S
ID
E
W
A
L
K
5
' S
ID
E
W
A
L
K
PROPOSED STREET LIGHTS
TO BE COORDINATED W/ GA
POWER, ±100' ON CURB TYP.
8
6
0
8
6
2
8
5
9
8
6
2
8
6
0
8
5
9
8
6
3
5' BEAUTY STRIP
5' SIDEWALK
LONGVIEW RUN
55' R/W
L
O
N
G
V
I
E
W
R
U
N
5
5
'
R
/
W
L
O
N
G
V
I
E
W
R
U
N
5
5
'
R
/
W
L
O
N
G
V
I
E
W
C
T
5
5
'
R
/
W
7
0
'
R
1
5
'
R
3
5
'
R
3
5
'
R35'
R
3
5
'
R35'
PROPOSED FIRE
HYDRANT
Ca
CvF
CvF
Ca
EX FIRE HYDRANT
EX FIRE HYDRANT
EX FIRE HYDRANT
PROPOSED FIRE HYDRANT
PROPOSED FIRE HYDRANT
PROPOSED FIRE HYDRANT
EXISTING
PARKING LOT FOR OVERALL
DEVELOPMENT AMENITY AREA
(INCLUDES POOL AND PLAYGROUND)
PI
SCALE:
SHEET NUMBER:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
INITIAL ISSUE DATE:
JOB NUMBER:
C-2
200124
09/16/2020
RG/DC
JK
JK
1"=30'
GSWCC LEVEL II CERTIFICATION NO. 31908
EXPIRES: 01/22/2022
FO
R
LO
NG
VIE
W R
UN
LA
ND
L
OT
9
&
2
4 ~
1
6T
H D
IS
TR
IC
T
DE
KA
LB
C
OU
NT
Y, G
EO
RG
IA
OWNER
STB LOTS, LLC
5755 DUPREE DR NW #130
ATLANTA, GA 30327-4352
DEVELOPER (PRIMARY PERMITTEE):
VENTURE COMMUNITIES, LLC
5500 INTERSTATE NORTH PKWY
SUITE 150
SANDY SPRINGS, GA 30328
PHONE: (770) 616-7515
24 HOUR EMERGENCY CONTACT:
BOB WHITE (770) 616-7515
ENGINEER:
WATTS & BROWNING ENGINEERS, INC.
1349 OLD 41 HWY NW, SUITE #225
MARIETTA, GA 30060
PHONE: (678) 324-6192
FAX: (770) 694-6870
CONTACT: DARYL COOK
THIS SKETCH PLAT HAS BEEN SUBMITTED TO AND APPROVED BY THE PLANNING
COMMISSION OF DEKALB COUNTY,
ON THIS . DAY OF . 20 .
BY: . DIRECTOR
PLANNING COMMISION CHAIRMAN
DEKALB COUNTY, GEORGIA.
SK
ET
CH
P
LA
T - S
IT
E P
LA
N
STORMWATER
FACILITY
DEVELOPMENT DATA
TOTAL SITE AREA: 6.20 AC
CURRENT ZONING: MU-4
PROPOSED UNITS: 38 UNITS
PROPOSED DENSITY: 6.13 UNITS/AC
REQUIRED OPEN SPACE: 20% (1.4 AC)
PROPOSED OPEN SPACE: 51% (3.6 AC)
MAXIMUM LOT COVERAGE: 90%
MINIMUM DWELLING UNIT SIZE: 850 SF
MAXIMUM BUILDING HEIGHT: 45' OR 3 STORIES
(WHICHEVER IS LESS)
MINIMUM LOT WIDTH: 20'
GUEST PARKING: 13 SPACES
SETBACKS:
FRONT: 15'
REAR: 10'
SIDE: 0'
SIDE CORNER: 5'
DEVELOPMENT OF RESIDENTIAL TOWNHOMES. PROJECT IS
LOCATES AT 2641 ACUITY WAY/2620 SHELL BARK ROAD.
SITE IS 6.2 ACRES AND WILL HAVE 38 UNITS.
COMBINATION PLAT AP#67987986 (PERMIT#1244433)
GENERAL NOTES:
1. THE TOPOGRAPHIC AND ELEVATION DATA SHOWN HERON WAS OBTAINED FROM
BOUNDARY & TOPOGRAPHIC INFORMATION FROM A SURVEY FOR VENTURE
COMMUNITIES, LLC BY NORTH POINT LAND SURVEYING, DATED APRIL 22, 2020 AND IS
NOT CERTIFIED AS CORRECT BY THE ENGINEER. USERS OF THIS DATA DO SO AT THEIR
OWN RISK.
2. NO HISTORIC FEATURES HAVE BEEN FOUND ONSITE. CONTOUR INTERVAL IS 1', BASED
ON NAD83 DATUM.
3. THE DEVELOPED SITE WILL CONSIST OF 38 TOWN HOMES.
4. KNOWN SANITARY SEWER AND WATERMAIN LINES AND EASEMENTS ARE SHOWN.
5. NO WETLANDS EXIST OUTSIDE OF THE FLOOD PLAIN OR WITHIN THE PROPOSED LIMITS
OF DISTURBANCE, TO THE BEST OF OUR KNOWLEDGE.
6. SNAPFINGER CREEK TRIBUTARY 3 IS THE RECEIVING WATERS.
7. NO BURY PITS ARE KNOWN TO EXIST OR ARE PROPOSED.
8. ROADWAYS WILL BE 24' BC/BC & PUBLIC W/ 55' ROW, CONSTRUCTED TO DEKALB
COUNTY STANDARDS.
9. WATER & FIRE SERVICES WILL BE PUBLICLY MAINTAINED BY DEKALB COUNTY, VIA
EASEMENTS.
10. ELECTRIC SERVICE WILL BE UNDERGROUND AND PROVIDED BY GEORGIA POWER.
11. SANITARY SEWER & WATER SERVICES WILL BE PROVIDED BY DEKALB COUNTY. NO
SEPTIC TANKS EXIST ONSITE OR ARE PROPOSED.
12. A 75' TRIBUTARY BUFFER MEASURED FROM THE POINT OF WRESTED VEGETATION,
WILL BE MAINTAINED ON ALL STATE WATERS THAT ARE NOT APPROVED FOR A BUFFER
ENCROACHMENT VARIANCE BY DEKALB COUNTY OR GA. E.P.D.
13. SKETCH PLAT APPROVAL DOES NOT CONSTITUTE APPROVAL OF THE STORM DRAINAGE
OR SANITARY SEWER SYSTEMS. NO CONSTRUCTION SHALL BEGIN UNTIL
CONSTRUCTION PLANS ARE APPROVED AND A DEVELOPMENT PERMIT IS OBTAINED.
14. THE OWNER OF THE PROPERTY IS RESPONSIBLE FOR COMPLIANCE WITH THE CORPS
OF ENGINEERS REQUIREMENTS REGARDING WETLANDS.
15. A MANDATORY HOME OWNERS ASSOCIATION IS REQUIRED FOR MAINTENANCE OF
ACCESS DRIVES, UTILITIES, AND STORM MANAGEMENT FACILITIES WITHIN COMMON
AREAS AND TO PROVIDE A DECLARATION OF PROTECTIVE COVENANTS AND
CONDITIONS ADDRESSING MAINTENANCE RESPONSIBILITY.
16. MOST OF THE PROPOSED DISTURBED AREA FALLS WITHIN EXISTING DISTURBED
AREAS. THERE ARE NO SPECIMEN TREES LOCATED WITHIN THE PROPOSED AREAS OF
DISTURBANCE. MU-4 PRESERVATION REQUIREMENTS WILL BE MET.
17. ALL UNITS TO BE INDIVIDUALLY METERED (WATER).
18. DEKALB COUNTY SANITATION DEPARTMENT WILL BE RESPONSIBLE FOR HANDLING
HOUSEHOLD WASTE, YARD DEBRIS AND RECYCLABLE MATERIAL.
19. 72 HOURS NOTICE IS REQUIRED TO GEORGIA 811 UTILITY PROTECTION CENTER
BEFORE ANY PLANNED DIGGING, http://www.georgia811.com
20. DEKALB COUNTY IS NOT RESPONSIBLE FOR ANY ERRORS OR OMISSIONS BY
ENGINEERS OR OTHER DESIGN PROFESSIONALS ON DESIGN OR COUNTY CODE
REQUIREMENTS FOR THIS PROJECT.
21. THIS SITE WAS A FUTURE PHASE OF LONGVIEW POINTE SUBDIVISION.
22. NO KNOWN PERMITS ARE ACTIVE FOR THIS SITE.
23. NO STREET PARKING SHALL BE ALLOWED, AND SIGNAGE SHALL BE POSTED.
24. IF THE ROAD WIDTHS ARE LESS THAN 26' WITH BUILDING HEIGHTS EXCEEDING 35 FEET,
THEN THE BUILDING SHALL INCLUDE FIRE SPRINKLER SYSTEMS. NFPA 13D ARE
ACCEPTABLE
25. UNIT 28 TRASH CART TO BE PLACED NEAR UNITS 27/26 FOR PICKUP
26. WATERSHED NOTES: ALL 6” SS LATS & 8” SS MAIN WITHIN ROW TO BE DIP, PLACE PVC
CO 1’ INSIDE ROW, NO BLDG AND/OR PATIOS IN SSE, PLACE WATER MAIN 3’ BEHIND
CURB, WATER SERVICE MAY BE 1” & SPLIT INTO 2 ¾”, PLACE METER BOXES BETWEEN
SIDEWALK & BOC OR BETWEEN SIDEWALK & EXTEND MAIN FROM ROAD C TO ‘LOOP’ &
CONNECT TO MAIN IN ACUITY WAY
27. ROW WILL BE DEDICATED TO PROVIDE 1' BEHIND THE EXISTING SIDEWALK ON ACUITY
WAY NEAR PANOLA IND TO ALLOW FOR STREET LIGHT PLACEMENT
28. A STORM WATER BMP IS PROPOSED AND WILL BE DESIGNED DURING LDP PERMITTING.
29. PERVIOUS PAVERS PLACED IN THE FLOOD PLAIN SHALL NOT REDUCE THE FLOOD PLAIN
VOLUME/CAPACITY.
SOILS LEGEND
Ca CARTECAY SILT LOAM, FREQUENTLY FLOODED0.6"-2"/HOUR
PERMIBILITY
0.6"-2"/HOUR
HsB HIWASSEE SANDY LOAM, 2 TO 6 PERCENT SLOPES0.6"-2"/HOUR
CvF CHESTATEE STONY SANDY LOAM, 15 TO 45 PERCENT SLOPES
0.6"-2"/HOUR
PfC PACOLET SANDY LOAM, 2 TO 10 PERCENT SLOPES0.6"-2"/HOUR
HtC2 HIWASSEE CLAY LOAM, 6 TO 10 PERCENT SLOPES, ERODED
XxXx
SOIL BOUNDARY
SOIL TYPE LABEL
1
2
-
0
1
-
2
0
THE SITE AREA SOUTH OF THE CREEK HAS
BEEN PREVIOUSLY CLEARED AND GRADED.
THIS AREA NOW HAS SMALL DIAMETER TREES.
THERE ARE NO SPECIMEN TREES ON THIS SITE.
\\hercules\E
ngineering D
ata\E
NG
R\200124\dw
g\200124-S
IT
E-U
TIL-E
RO
S.dw
g, 12/1/2020 12:15:00 P
M, _A
utoC
AD
P
DF
(G
eneral D
ocum
entation).pc3
AutoCAD SHX Text-
AutoCAD SHX Text15'BL
AutoCAD SHX Text15'BL
AutoCAD SHX Text15'BL
AutoCAD SHX Text15'BL
AutoCAD SHX Text25' BUFFER
AutoCAD SHX Text75' BUFFER
AutoCAD SHX TextCL CREEK
AutoCAD SHX TextCL CREEK
AutoCAD SHX TextW
AutoCAD SHX TextS
AutoCAD SHX TextW
AutoCAD SHX TextS
AutoCAD SHX TextS
AutoCAD SHX TextS
AutoCAD SHX TextS
AutoCAD SHX TextW
AutoCAD SHX TextW
AutoCAD SHX TextS
AutoCAD SHX TextWRESTED VEGITATION
AutoCAD SHX TextWRESTED VEGITATION
AutoCAD SHX TextWRESTED VEGITATION
AutoCAD SHX TextWRESTED VEGITATION
AutoCAD SHX TextFIRE HYD.
AutoCAD SHX TextWATER VALVE
AutoCAD SHX TextWATER VALVE
AutoCAD SHX TextS
AutoCAD SHX TextS
AutoCAD SHX TextW
AutoCAD SHX TextCONC. FLUME
AutoCAD SHX TextIPF 1/2"RB
AutoCAD SHX TextIPF 1/2"RB
AutoCAD SHX TextOPEN SPACE
AutoCAD SHX Text-
AutoCAD SHX Text-
AutoCAD SHX Text-
AutoCAD SHX Text-
AutoCAD SHX TextIPF
AutoCAD SHX TextIPF
AutoCAD SHX Text-
AutoCAD SHX Text-
AutoCAD SHX Text-
AutoCAD SHX Text25' BUFFER
AutoCAD SHX Text20'SSE
AutoCAD SHX Text20'SSE
AutoCAD SHX Text20'SSE
AutoCAD SHX Text20'SSE
AutoCAD SHX Text20'SSE
AutoCAD SHX Text20'SSE
AutoCAD SHX Text25' BUFFER
AutoCAD SHX TextIPF 1/2"RB
AutoCAD SHX TextIPF 1/2"RB
AutoCAD SHX Text15'BL
AutoCAD SHX Text15'BL
AutoCAD SHX Text20'SSE
AutoCAD SHX TextN48°21'54"E344.05'
AutoCAD SHX TextN33°58'17"E97.50'
AutoCAD SHX TextN20°33'56"E376.29'
AutoCAD SHX Text118.65' S89°27'18"W
AutoCAD SHX Text164.32' N84°55'24"W
AutoCAD SHX Text171.51' N65°06'34"W
AutoCAD SHX TextS14°40'12"E150.00'
AutoCAD SHX TextA=458.59' S05°19'48"WLc=449.33' R=656.87'
AutoCAD SHX Text89.92' S25°19'37"W
AutoCAD SHX Text-
AutoCAD SHX TextN00°00'12"E309.46'
AutoCAD SHX TextOPEN SPACE
AutoCAD SHX TextOPEN SPACE
AutoCAD SHX Text15'BL & L/S
AutoCAD SHX Text15'BL & L/S
AutoCAD SHX Text15'BL & L/S
AutoCAD SHX TextFLOODLINE (APPROX.)
AutoCAD SHX TextFLOODLINE (APPROX.)
AutoCAD SHX TextFLOODLINE (APPROX.)
AutoCAD SHX TextFLOODLINE (APPROX.)
AutoCAD SHX Text75' BUFFER
AutoCAD SHX TextFLOOD ZONE AE
AutoCAD SHX TextFLOOD ZONE AE
AutoCAD SHX TextFLOOD ZONE AE
AutoCAD SHX TextZONE X-UNSHADED
AutoCAD SHX TextZONE X-UNSHADED
AutoCAD SHX TextZONE X-UNSHADED
AutoCAD SHX TextLAND LOT LINE APPROX
AutoCAD SHX Text72" RCP
AutoCAD SHX Text72" RCP
AutoCAD SHX Text72" RCP
AutoCAD SHX TextJB
AutoCAD SHX TextA=135.61' S11°20'56"ELc=135.53' R=1169.98'
AutoCAD SHX Text24" CMP
AutoCAD SHX Text24" CMP
AutoCAD SHX TextS
AutoCAD SHX Text54" CMP
AutoCAD SHX TextJB
AutoCAD SHX Text60" CMP
AutoCAD SHX Text60" CMP
AutoCAD SHX TextIPF 1/2"RB
AutoCAD SHX Text54" CMP
AutoCAD SHX Text48" CMP
AutoCAD SHX Text860
AutoCAD SHX Text860
AutoCAD SHX Text855
AutoCAD SHX Text830
AutoCAD SHX Text830
AutoCAD SHX Text835
AutoCAD SHX Text835
AutoCAD SHX Text840
AutoCAD SHX Text840
AutoCAD SHX Text840
AutoCAD SHX Text845
AutoCAD SHX Text845
AutoCAD SHX Text845
AutoCAD SHX Text845
AutoCAD SHX Text850
AutoCAD SHX Text850
AutoCAD SHX Text850
AutoCAD SHX Text855
AutoCAD SHX Text855
AutoCAD SHX Text845
AutoCAD SHX Text865
AutoCAD SHX Text865
AutoCAD SHX Text855
AutoCAD SHX Text75' BUFFER
AutoCAD SHX TextSNAPFINGER CREEK TRIBUTARY 3
AutoCAD SHX TextSNAPFINGER CREEK TRIBUTARY 3
AutoCAD SHX Text%%P4,000LF TO SNAPFINGER CREEK
AutoCAD SHX TextNO. DATE BY DESCRIPTION
AutoCAD SHX TextREVISIONS
AutoCAD SHX TextWATTS & BROWNING ENGINEERS, INC.
AutoCAD SHX TextCIVIL ENGINEERS & LAND SURVEYORS
AutoCAD SHX TextWWW.WBENGR.COM
AutoCAD SHX TextFAX: (770) 694-6870
AutoCAD SHX TextPHONE:(678) 324-6192
AutoCAD SHX Text1349 OLD 41 HWY NW, SUITE #225
AutoCAD SHX TextMARIETTA, GEORGIA 30060
AutoCAD SHX TextLSF000429 - PEF000714
AutoCAD SHX Text0
AutoCAD SHX TextGRAPHIC SCALE
AutoCAD SHX Text( IN FEET )
AutoCAD SHX Text1 inch = ft.
AutoCAD SHX Text30
AutoCAD SHX Text60
AutoCAD SHX Text30
AutoCAD SHX Text30
AutoCAD SHX TextGRID NORTH - WEST ZONE
AutoCAD SHX Text1 09-16-20 JK SKETCH PLAT
AutoCAD SHX Text2 12-01-20 RTG ADDRESS SKETCH PLAT COMMENTS
SCALE:
SHEET NUMBER:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
INITIAL ISSUE DATE:
JOB NUMBER:
Z-1
200124
09/16/2020
RG/DC
JK
JK
N/A
GSWCC LEVEL II CERTIFICATION NO. 31908
EXPIRES: 01/22/2022
1
2
-
0
1
-
2
0
FO
R
LO
NG
VIE
W R
UN
LA
ND
L
OT
9
&
2
4 ~
1
6T
H D
IS
TR
IC
T
DE
KA
LB
C
OU
NT
Y, G
EO
RG
IA
ZO
NIN
G M
IN
UT
ES
\\hercules\E
ngineering D
ata\E
NG
R\200124\dw
g\200124-C
OV
ER
-D
ET
AILS
.dw
g, 12/1/2020 12:15:16 P
M, _A
utoC
AD
P
DF
(G
eneral D
ocum
entation).pc3
AutoCAD SHX TextNO. DATE BY DESCRIPTION
AutoCAD SHX TextREVISIONS
AutoCAD SHX TextWATTS & BROWNING ENGINEERS, INC.
AutoCAD SHX TextCIVIL ENGINEERS & LAND SURVEYORS
AutoCAD SHX TextWWW.WBENGR.COM
AutoCAD SHX TextFAX: (770) 694-6870
AutoCAD SHX TextPHONE:(678) 324-6192
AutoCAD SHX Text1349 OLD 41 HWY NW, SUITE #225
AutoCAD SHX TextMARIETTA, GEORGIA 30060
AutoCAD SHX TextLSF000429 - PEF000714
AutoCAD SHX Text1 09-16-20 JK SKETCH PLAT
AutoCAD SHX Text2 12-01-20 RTG ADDRESS SKETCH PLAT COMMENTS
\\hercules\E
ngineering D
ata\E
NG
R\200124\dw
g\200124-C
OV
ER
-D
ET
AILS
.dw
g, 12/1/2020 12:15:21 P
M, _A
utoC
AD
P
DF
(G
eneral D
ocum
entation).pc3
Sheets and ViewsC-1 SKETCH PLAT - COVER SHEETC-2 SKETCH PLAT - SITE PLANZ-1 ZONING MINUTESTS-1 TREE SURVEY (BY OTHERS)