Long Term Operation and Plans for Tests at GIF
CMS GEM Upgrade Workshop III
Jeremie MERLIN and Christopher Armaingaud(University of Strasbourg*)
* Also at Telecom Physique Strasbourg April 20,2012
Long Term Operation and Plans for Tests at GIF
Jeremie MERLIN
Christopher ArmaingaudApril 20,2012CMS GEM Upgrade Workshop III
Introduction to the ageing process
The ageing process Polymer formation in the avalanche plasma Direct deposition of pollutants Appearance of reactive gas/products in the avalanche process
From M. Capeans, Ageing of Gaseous Detectors : assembly materials and procedures, CERN
2/9
Long Term Operation and Plans for Tests at GIF
Jeremie MERLIN
Christopher ArmaingaudApril 20,2012CMS GEM Upgrade Workshop III
Introduction to the ageing process
The aim of the ageing test Ensure a long term operation in CMS Understand the effects of the radiation on the materials If there is ageing, understand its origin and propose solutions
50μm
3/9
Long Term Operation and Plans for Tests at GIF
Jeremie MERLIN
Christopher ArmaingaudApril 20,2012CMS GEM Upgrade Workshop III
The previous ageing measurements-double GEM-
Standard operation conditions Ar/CO2 : 70/30
Setup 6 keV X-rays, rate: 4,75.104 Hz/mm2
Drift: 2kV/cm , Others: 4kV/cm Gain: 2,2.103
Data from S. Bachmann et al.,Development and test of large size GEM detectors, IEEE Trans. Nucl. Sci. NS-47 (2000) 1412
4/9
Long Term Operation and Plans for Tests at GIF
Jeremie MERLIN
Christopher ArmaingaudApril 20,2012CMS GEM Upgrade Workshop III
The previous ageing measurements-triple GEM-
Standard operation conditions Ar/CO2 : 70/30
Setup 8,9 keV X-rays, rate: 103 - 104 Hz/mm2
Drift: 2,5kV/cm , Others: 3,7kV/cm Gain: 8,5.103
Data from M. C. Altunbas et al., Aging Measurements with the Gas Electron Multiplier (GEM), CERN-EP/2001-091
5/9
Long Term Operation and Plans for Tests at GIF
Jeremie MERLIN
Christopher ArmaingaudApril 20,2012CMS GEM Upgrade Workshop III
The ongoing ageing test
Standard operation conditions Ar/CO2/CF4 : 45/15/40
Setup 137Cs source, A: 566 GBq Drift: 3kV/cm , Others: 3,5kV/cm-5kV/cm Gain: 8.103 - 104
During 6 months in the GIF
6/9
Long Term Operation and Plans for Tests at GIF
Jeremie MERLIN
Christopher ArmaingaudApril 20,2012CMS GEM Upgrade Workshop III
The ongoing ageing test-Gamma Irradiation Facility-
From I. Brunner, Integrated dose around the GIF installation from June to September 2004, CERN-SC-2004-077-RP-SN
GEM
lead
shi
eld
7/9
AmplifierPreamplifier50x
Input : negativeOutput Range : 10VInt/Diff : 0.25/0.25
BLR : out
unipolar
Discriminator
Linear fan in/fan out
Readout Connections
5 l/
h
Attenuator
GATE
ADC (965)
VME
CPU
C-programGND
PicoammeterGND
GPIB
LabView-program
Mass Chromatography
Gas Output
Gas input
Meteo Station
PressureTemp°Humidity
GND
LEAD SHIELDSWPC
SWPC
Dual Timer
VETO
GATE/RATE
Multii-Channels
Common Gate
GIF EXPERIMENTOVERVIEW
Power Supply System
HV
Long Term Operation and Plans for Tests at GIF
Jeremie MERLIN
Christopher ArmaingaudApril 20,2012
The ageing test-setup-
8/9
Long Term Operation and Plans for Tests at GIF
Jeremie MERLIN
Christopher ArmaingaudApril 20,2012CMS GEM Upgrade Workshop III
Thank you