14
GE Healthcare GE Healthcare LOGIQ e LOGIQ e product description: LOGIQ* e gives physicians the power to expand from routineto advanced ultrasound imaging. GE Healthcare’s leadership compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications. A variety of premium technologies help care for a broad spectrum of patients, from superficial to dynamic or deep imaging at the point of care. Point of Care versatility The LOGIQ e excels in the following areas: Amazingly Accurate Anatomy: Our Tissue Differentiation comes from the combination of our proprietary imaging technology, beamformer and ultra-high frequency L8-18i-RS transducer. This helps you detect subtle changes in anatomy, minimal amounts of fluid and small structures. Power Doppler Imaging (PDI) sensitivity detects slow blood flow in both small and large vessels. B-Steer + Needle Recognition delivers accurate detail—needle, anatomy and motion—even in Color and Power Doppler. Precision Tools: Patient Follow-up Tool automatically sets all of the imaging parameters to be identical to your previous exam. This helps give you technical consistency when you monitor your patient’s condition, therapy or progress over time. Color and PDI Quantification helps you evaluate the amount of blood flow within a specific area, to assist with diagnosis and monitoring. Other advanced capabilities are intuitive to use, such as Simultaneous Split Screen, LOGIQview panoramic imaging, and Raw Data Imaging. Simplicity creates efficiency. Customize to your needs: You can spend more time focusing on your patient and not your equipment. The system comes with expertly optimized image settings readily available on the LOGIQ e. Auto Optimize helps you quickly adjust image quality with the touch of one button. To personalize your system, you have the flexibility to fine- tune the image across all modes and save your settings. You can even create up to eight of your own default settings by anatomy, procedure or physician. To quickly streamline your system, you can select only the capabilities you need for your clinic or facility. In addition, efficient data management and connectivity make documentation easy over a wired or wireless network.

LOGIQ - MedPlus Equipment Services · 2020. 11. 27. · GE Healthcare LOGIQ e LOGIQ e product description: LOGIQ* e gives physicians the power to expand from routineto advanced ultrasound

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

  • GE HealthcareGE Healthcare

    LOGIQ eLOGIQ e product description:LOGIQ* e gives physicians the power to expand from routineto advanced ultrasound imaging. GE Healthcare’s leadership compact system is designed for general imaging, musculoskeletal, anesthesiology, interventional, emergency, and critical care applications. A variety of premium technologies help care for a broad spectrum of patients, from superficial to dynamic or deep imaging at the point of care.

    Point of Care versatilityThe LOGIQ e excels in the following areas:Amazingly Accurate Anatomy: Our Tissue Differentiation comes from the combination of our proprietary imaging technology, beamformer and ultra-high frequency L8-18i-RS transducer. This helps you detect subtle changes in anatomy, minimal amounts of fluid and small structures. Power Doppler Imaging (PDI) sensitivity detects slow blood flow in both small and large vessels. B-Steer + Needle Recognition delivers accurate detail—needle, anatomy and motion—even in Color and Power Doppler.

    Precision Tools: Patient Follow-up Tool automatically sets all of the imaging parameters to be identical to your previous exam. This helps give you technical consistency when you monitor your patient’s condition, therapy or progress over time. Color and PDI Quantification helps you evaluate the amount of blood flow within a specific area, to assist with diagnosis and monitoring. Other advanced capabilities are intuitive to use, such as Simultaneous Split Screen, LOGIQview panoramic imaging, and Raw Data Imaging.

    Simplicity creates efficiency. Customize to your needs: You can spend more time focusing on your patient and not your equipment. The system comes with expertly optimized image settings readily available on the LOGIQ e. Auto Optimize helps you quickly adjust image quality with the touch of one button. To personalize your system, you have the flexibility to fine-tune the image across all modes and save your settings. You can even create up to eight of your own default settings by anatomy, procedure or physician. To quickly streamline your system, you can select only the capabilities you need for your clinic or facility. In addition, efficient data management and connectivity make documentation easy over a wired or wireless network.

  • 2

    General SpecificationsDimensions and Weight• Height: 70mm(2.75in)consoleonly

    100mm(3.94in)withhandle• Width: 340mm(13.38in)• Depth: 346mm(11.63in)consoleonly

    372mm(14.4in)withhandle• WeightwithBattery: approx.5.2Kg(11.5lbs).

    Battery Power• LithiumIonBattery(standard)• Scantimewithbattery1hour

    Electrical Power• Voltage:100–240VAC• Frequency:50/60Hz• Power:Max.130VAwithPeripherals

    Console Design• LaptopStyle• IntegratedHDD(160GB)• CPU –U7500Core2Duo1.06G• Wired,wirelessLANSupport –ForDICOMcommunication –ForNetworkStorage(Image

    storetoPCwithoutDICOMsystem)• USBPorts(2)• USBECG(AHA/IEC)(Optional)Support• CWD(Optional)Support• 1probeportwithmicro-connector• Rearhandle

    User InterfaceOperator Keyboard• AlphanumericKeyboard• ErgonomicHardKeyOperations• IntegratedRecordingKeysfor PeripheralandDICOMDevices

    • 6TGCPods,withremapping functionality at any depth

    • Backlightkeys

    Display Screen• 15inchHigh-ResolutionColorLCD –Displaysize:1024x768• InteractiveDynamicSoftwareMenu• OpenAngleAdjustable –0to160°• IntegratedSpeakers• BrightnessAdjustment• AudioVolumeAdjustment

    System OverviewApplications• Abdominal• Cardiac• Gynecology• Intraoperative• Musculoskeletal• Obstetrical• NerveBlock• PediatricandNeonatal• SmallPartsandSuperficial• Urological• Vascular

    Scanning Methods• PhasedArraySector• ElectronicConvex• ElectronicLinear

    Transducer Types• ConvexArray• MicroconvexArray• LinearArray• PhasedArray

    Operating Modes• B-Mode• M-Mode• AnatomicalM-Mode• ColorFlowMode(CFM)• PowerDopplerImaging(PDI)• ContinuousWaveDoppler(CWD)• PulseWaveDoppler(PWD)• TissueDopplerImaging(TDIassess

    direction and velocity of myocardial motion)

    Standard Features• HighResolution15inchColorLCD• Over1,000framesorover60secondsCINEMemory(64MB)dependonFOV,Scanning Lines etc.

    • 160GBHardDrive• ExternalDVDR/Wstorage• Loopstorage—fromlivescanning

    and from memory• AutomaticOptimization –AutoTissueOptimization:ATO –AutoColorFlowOptimization:ACO –AutoSpectrumOptimization:ASO –AutoClaritySuite(AutoFocusand

    Auto Frequency)• ACE*(AdaptiveColorEnhancement)

    • RawDataProcessing• PatientInformationDatabase• ImageArchive97.5GBonHardDrive• CustomizableUserInterface• FullM&ACalculationPackagewith

    Real Time Auto Doppler Calculations• VascularCalcs• CardiacCalcs• OBCalcsandTables• FetalTrending• MultiGestationalCalcs• Musculoskeletaland

    Hip Dysplasia Calcs• GynecologicalCalcs• UrologicalCalcs• RenalCalcs• ReportPackage

    Software Options• Easy3D• LOGIQview• B-Steer+NeedleRecognition• CrossXBeam*• CMMandAMM• StressEcho• TEEProbeSupport• TDI• IMT• TouchMode• DICOM3.0Connectivity• eSmart Trainer provides modules

    showing basic scanning techniques, with graphics of probe position, anatomy and example clinical image

    • Flow QA (Color and PDI Quantification) helps you evaluate the amount of blood flow within a region of interest, to assist with diagnosis and monitoring.

    • Patient Follow-up Tool when you monitor your patient’s condition, therapy or progress over time - LOGIQ e automatically recalls all of the imaging parameters, comments and body patterns to be identical to your previous exam. It even provides an alert if you use a different transducer thanlasttime.WorksinB-Mode,ColorModeandPDI.

    Hardware Options• CWD• USBECG(AHA/IEC)• 1.5THardDrive• SATAtoUSBconvertor

  • 3

    Cart & Peripheral Options• StreamlineCart –Smallfootprint –Adjustableheight –Optionalbasketorlockingdrawer

    Depth:512mm Width:540mm Height:830–1,130mm

    • PortableDockingStation Adjustable platform height Digital/Analogvideooutput

    –3Probeportadapter(option) –Externalspeaker(option) –15inchExtratouchscreen(option) - Total height with LCD:

    1,385mm±3mm Depth:617mm±2mm Width:470mm±1.5mm Weight:59kg±1.0kg

    - Total height with TouchScreen (option): 1,740mm±3mm Depth:625mm±2mm Width:473mm±1.5mm Weight:70kg±1.0kg

    • 3pedalFootSwitch(IPX8)(option)• 1pedalFootSwitch(IPX8)(option)• ExternalUSBDVD-RW(standard)• USBthermalB&Wprinter(option)• USBthermalcolorprinter(option)• USBDeskJetcolorprinter(option)• NetGearUSBWirelessAdapter WNA3100supportingthe802.11a/b/gformats, where available (option)

    • MemoryStick(option)• USB2.0Hub(option)• USBHDD(option)• Barcodescanner(1D,2D),HPP4600g

    (option)• Barcodescanner(1D),HHP3800g

    (option)

    Display Modes• SimultaneousCapability –B/PWorTDI –B/CFMorPDI –B/MorAMM –DualB(B/B) –DualB+CFMorPDI –DualB-Steer+Needle

    Recognition+B-Mode –B-Steer+NeedleRecognition

    +CFM(PDI) –Real-timeTriplexMode• SelectableAlternatingModes –B-Steer+NeedleRecognition

    –B/M –B/PWorTDI –B/CW –B+CFM(PDI)/M(optional) –B+CFM(PDI)/PW –B+CFM(PDI)/CW –3D–Mode(option)• MultiImageSplitScreen –Liveand/orfrozen –B+B/CFMorPDI –IndependentCineplayback –Conventionalorwidescreendisplay• Zoom:Read/Panandfromarchive• ColorizedImage –ColorizedB –ColorizedM –ColorizedPW –ColorizedCW• TimelineDisplay –IndependentDualB/PW/CWDisplay –DisplayFormats:

    Top/BottomorSide/SideselectableFormatSize:Vert1/3B;Vert1/2B;Vert2/3B;Horiz1/2B;Horiz1/4B;TLOnly format, switchable after freeze

    –Updatemode:timedbasedonsweep• QuadScreenDisplayaccessfrom

    Split Screen

    Display Annotation• Institution/HospitalName• Date:2typesselectableMM/DD/YY,DD/MM/YY

    • Time:2typesselectable24hours, 12 hours

    • OperatorIdentification• PatientName:First,Last,&Middle• PatientIdentification:64characters• GestationalAgefromLMP/EDD/GA/BBT• PowerOutputReadout –MI:MechanicalIndex –TIS:ThermalIndexSoftTissue –TIC:ThermalIndexCranial(Bone) –TIB:ThermalIndexBone• SystemStatus(real-timeorfrozen)• ProbeOrientationMarker:

    Coincides with orientation marking on the image monitor

    • ImagePreview• Gray/ColorBar• CineGauge• MeasurementSummaryWindow• MeasurementResultsWindow:

    pre-settable display location

    • ProbeType• ApplicationName• ImagingParametersbyMode (currentmode/seebelow)

    • FocalZoneMarkers• BodyPattern:219types• BScaleMarkers:2types; Depth/Width

    • MScaleMarkers:2types; Time/Depth,Time

    • ImageManagementMenu: Menu,Delete,andImageManager

    • ImagePalette• CapsLock:On/Off• SystemMessagesDisplay• TrackballFunctionalityStatus:Scroll,M&A(MeasurementandAnalysis),Position,Size,ScanAreaWidth, and Tilt

    • BatteryStatus• BiopsyGuideLineandZone• HeartRate

    Primary Parameter Menu, mode dependent –B-Mode

    Frequency VirtualConvex/VirtualApex CrossXBeam Edge Enhance Dynamic Range Rotation GrayMap Focus Position Focus Number Colorize

    –ColorFlowMode Frequency Threshold Spatial Filter Packet Size Angle Steer Invert PRF Map WallFilter

    –PWMode SVLength Sweep Speed Angle Steer Quick Angle Spectral Invert Frequency Angle Correct Baseline PRF WallFilter

  • 4

    –TDIMode Frequency Sweep Speed Angle Correct Baseline Scale Angle Steer Quick Angle Invert LowVelocityReject

    –M-Mode Frequency Transparency Axial Filter Power Output PRF Baseline GrayMap Threshold Invert WallFilter

    –CineMode Loop Speed Cycle Select Start Frame End Frame Frame by Frame Select All First Frame Last Frame Run/Stop CineModeSelection

    • SecondaryParametersMenu –B-Mode

    Frame Average Biopsy Line Density FocusWidth B Softener Power Output Suppression Range Focus SRI Rotation Focus Number

    –CFMode Baseline Line Density Flash Suppression TransparencyMap Focus Position Frame Average Power Output

    –PW/TDIMode Rejection Compression Display Format Full Timeline TraceMethod Trace Sensitivity

    Trace Direction ModifyAutoCalcs PW/CFRatio Duplex Time Resolution Colorize GrayMap Power Output Auto Calcs Spectral Average Cycles to Average

    –CWMode Dynamic Range Display Format Full Timeline TraceMethod Trace Sensitivity Trace Direction ModifyCalcs Time Resolution Colorize Power Output Auto Calcs Spectral Average Cycles, to Change

    System ParametersSystem Setup• DiagnosticCategories(pre-settable):Abdomen,OB,GYN,Cardiac,Vascular,Urology,Pediatric,SmallParts, Musculoskeletal

    • UserProgrammablePresetCapability• FactoryDefaultPresetData• Languagessetup:English,Norwegian,

    French, German, Spanish, Italian, Portuguese, Russian, Greek, Finnish, Swedish, Dutch, Danish

    • LanguagesforManuals:English,Norwegian, Polish, French, German, Spanish, Italian, Portuguese, Russian, Greek, Finnish, Swedish, Dutch, Danish,Japanese

    • OperationErrorBeep• BodySurfaceArea:2types;

    Oriental, Occidental• OBReportFormat5types;TokyoUniv.,OsakaUniv.,USA,Europe,ASUM

    • EFBW:8types;TokyoUniv.,OsakaUniv.,USA,andEurope(Shephard,Merz,Hadlock/Shephard,Williams,Brenner)

    • CUA/AUAforHadlock• BodyPatternCopytoActiveSide: On/Off

    • ColorizedB/M:5typesforeach, PWD/CWD:6typesforeach

    • ProgrammableAnnotationLibrary: 44annotations

    • MenuSelectionatNewPatient: 2types;PatientEntry,Schedule

    • SortCriteriaforScheduleList: 2types;Date&Time,Name

    • PatientNameFormat:2types; FullName,Last,&First

    • Pre-settableDopplerAudioVolume• MeasurementClearOperation: 2types;Meas.only,withComment

    • DisplayUnitAge:3types;“Year/month,”“Week/day,”and“Nodisplay”

    • SystemBootUp:35seconds• ProbeChange:3–5seconds

    Pre-Processing• AcousticPowerOutput• ReadZoomupto8x• B/M-Mode –Gain –CrossXBeam –B-Steer+NeedleRecognition –PIH –TGC –ImageReverse –Depth –ScanArea –AutoOptimize(ATO) –DynamicRange –FocusNumber –FocusPosition –LineDensity –Frequency –FrameAverage –EdgeEnhance –FocusWidth –M/DCursor –SweepSpeedforM-Mode• PW/TDIMode –Gain –SampleVolumeGatePosition,Length –PRF –DopplerFrequency –DynamicRange –AutoOptimize(ASO) –AudioVolume• CWMode –Gain –Velocity –DopplerFrequency –DynamicRange –AutoOptimize(ASO) –AudioVolume

  • 5

    • ColorFlowMode –Gain –ROIPosition,Size –PRF –ColorLineDensity –ColorFrequency –PacketSize –Threshold –FrameAverage –FocusPosition –AutoOptimize(ACO)• 3DAcquisition(option) –ScanDistance –ScanPlane –AcquisitionMode

    Post-Processing• RawDatadigitalprocessing• ReadZoomupto8x• B/M-Mode –Gain –ImageReverse –AutoOptimize(ATO) –ImageRotation –GrayMap –Colorize –Rejection –BSoftener –SweepSpeedforM-Mode• PW/TDIMode –Gain –Baseline –AngleCorrect –QuickAngle –DopplerInvert –DisplayFormat –SweepSpeed –FullTimeline –Rejection –Colorize –Compression(DynamicRange) –AutoCalcs –TraceDirection –ModifyCalcs –NumberofAverageCycles –TraceMethod –TraceSensitivity –AutoOptimize(ASO)• CWMode –Gain –Baseline –AngleCorrect

    –QuickAngle –DopplerInvert –DisplayFormat –SweepSpeed –FullTimeline –Rejection –Colorize –Compression(DynamicRange) –AutoCalcs –TraceDirection –ModifyCalcs –NumberofAverageCycles –TraceMethod –TraceSensitivity –AutoOptimize(ASO)• ColorFlowMode –Gain –Baseline –ColorInvert –ColorMap –Threshold –FrameAverage(inloopimages)• Easy3D(option) –Threshold(Opacification) –Render –Texture –GraySurface –Scalpel –AutoMovie –Undo –Reset

    Image Processing and Presentation• DigitalBeamformer• BeamformerOperatingFrequencyRange:1.7–18MHz

    • Maximumframerate:1,972Hz(themaximum frame rate is affected by scan width, line density depth, and Focus number).

    • 1,024DigitalProcessingChannelTechnology

    • DisplayedImagingDepth:MinimumDepthofField:2cm(Zoomandprobedependent);MaximumDepthofField:30cm:probedependent

    • TransmissionFocus –1–8FocusPointsSelectable:

    probe and application dependent –FocalZonePosition• ContinuousDynamicReceive Focus/Aperture

    • Multi-Frequency/WidebandTechnology

    • 256ShadesofGray(VGA)• 174dBSystemInternalDynamicRange• AdjustableFieldofView(FOV)• ImageReverse:Right/Left• ImageRotation:2stepsRotation: 0°,180°

    CINE Memory/Image Memory• Over1,000framesorover60secCINEMemory(64MB)dependonFOV,Scanning Lines, etc.

    • CINEGaugeandCINEImage Number Display

    • CINEReview:Frame-by-frame,Loop• CINEReviewSpeed:8types48%;31%;25%;22%;17%;14%;13%;11%

    • SelectableCINESequencefor CINE Review

    • StartandEndFrameSelectionsforLoop Playback

    • SeparationMakertoIndicateTimeDiscontinuity

    • Measurements,Calculations,and Annotations on CINE Playback

    • ScrollingTimelineMemory

    Image Archive/Connectivity• PreviewandRecallofClipboard

    Images: An enlarged preview of the image is displayed or the image is recalled to full screen

    • ImageBrowser:Archivedimagesfrompast patient exams appear as well as images stored for the current exam

    –PreviewanImage –GroupaSetofImages –AnalyzeImages• ImageManagement –SelectAll/UnselectAll –PermanentStore –DeletealltheTemporaryImages –DeleteSelectedImage –Analyze• EthernetNetworkConnection• Configurable3Print/Store (Recordings)Keys(P1-P3)to MultipleOutputDevices/Workflows

    • ArchivingFormat: –DICOMwithultrasoundRawData –DICOM• CaptureArea:pre-settableforeach

    print key –VideoArea –ApplicationWindow –WholeScreen

  • 6

    • ArchivingImageFrames:pre-settablefor each print key

    –Single:storessingleframeonly –Multiple:storescineloop –SecondaryCapture:screenshot• ImageCompression/PictureQuality:

    pre-settable for each print key –Quality:1to100% –Dataflow:determineswhere/how

    imageswillbetransferred/stored• ConfigurableExaminationListWindow,PatientInformationWindow,andSearch/CreatePatientWindow

    –Freetextaddresses,birthdate,extended patient dialog in Pts Info window

    –Extendedsearchdialog,autosearchforpatientinSearch/CreatePts window

    –Pre-definedtextdirectlyinExamList window

    –AutomaticgenerationofpatientID –RequestacknowledgeofEnd

    Exam action –GodirectlytoPatientScreen/Worklist

    screen after [End Current Patient] –Detectunfinishedexamination• Tools –VerifyDICOMdirectoryon

    removable media –Formatremovablemedia

    (rewritableDVD)• Views:showsanoverviewofthe

    ultrasound system’s connectivity architecture

    –Thecurrentlyselecteddataflow –Allconfigureddataflows –Thenetworkstructuretree –Theconfiguredbuttonsdataflows• AVIandJPEGExport• QuickSave –Singlebuttonpushsendssingle

    image or entire patient exam to memory stick or network

    • DICOMSupport(option) –Verify –Print –Store –ModalityWorklist –Multiframe –StorageCommitment –ModalityPerformedProcedureStep

    (MPPS) –MediaExchange –Offnetwork/mobilestoragequeue

    Scanning Parameters B-Mode• B/MAcousticOutput:0–100%, 2%increments

    • ImageReverse:On/Off• BColorize:5types• ThermalIndex:TIC,TIS,TIB• Softener:4steps• FocusNumber:8steps• LineDensity:5-8increments:

    probe dependent• FrameAverage:6increments• EdgeEnhance:6increments• Angle(deg):probedependent,10°–133°

    • GrayScaleMap:40types• Gain:0–98dB,2dBincrements• DynamicRange:30–150dB,3dB

    increments: probe dependent • Harmonics:on/off• VirtualConvex:on/off• Depth:2–30cm,1cmsteps,0.5cm

    steps for Linear probe when less than 5cmdepth

    • FocusDepth:increments: probe dependent

    • Rejection:6increments• Frequency:3-5increments:probe

    dependent

    Color Flow Mode• BaseLine• Invert:On/Off• CF/PDIFocusDepth:11stepsdefault

    pre-settable• CF/PDIAcousticOutput:0–100%,10%increments

    • PacketSize:6-18:probedependent• LineDensity:5–8increments:

    probe dependent• FrameAverage:7increments• PRF:0.3K–11.4KHz:probedependent• SpatialFilter:6steps• Gain:0–40dB,0.5dBsteps• WallFilter:2–6steps:application

    and probe dependent• Angle/Width(deg,mm):

    probe dependent• CF/PDIVerticalSize(mm):

    default pre-settable• CF/PDICenterDepth(mm):

    default pre-settable• CF/PDIFrequency:2–4steps:

    probe dependent

    • CF/PDIFocalNumber:1• ColorMap:13typesatmost:

    application and probe dependent• ColorThreshold:10–100%,5%steps

    PDI Mode• PDIMap:13types• CF/PDIAcousticOutput:0–100%,10%steps

    • PacketSize:6–18:probedependent• SpatialFilter:6steps• FrameAverage:7steps:

    probe dependent• PRF:0.3K-11.4KHz:depthdependent• PowerThreshold:10–100%,5%steps• CF/PDIVerticalSize:

    default pre-settable • CF/PDICenterDepth:

    default pre-settable• CF/PDIFocalNumber:1• Gain:0–40dB,0.5dBsteps• WallFilter:6increments:

    probe dependent • CF/PDIFrequency:2–4increments:

    probe dependent

    M-Mode• SweepSpeed:8increments• MColor:5types• M/PWDisplayFormat:V-1/3B,V-1/2B,V-2/3B,H-1/2B,H-1/4B,TLOnly

    • B/MAcousticOutput:0–100%, 2%increments

    • Rejection:6increments• DynamicRange:30–120dB, 3dBincrements

    • EdgeEnhance:6increments• GrayScaleMap:40types• MGain:0–98dB,2dBincrements

    PW/TDI/CW Mode• MaximumandMinimumVelocityScales• PW Max:870cm/s,19,800Hz Min:15cm/s,700Hz• CW Max:1,460cm/s,40,000Hz Min:40cm/s,2,100Hz• GrayScaleMap:7types• DynamicRange:24–60,4dB

    increments: application dependent • BaseLine:5–95%• SVGate:1,2,3,4,5,6,7,8,9,10,12,14,16mm:applicationdependent

    • AngleCorrect:+/-90°,1°step

  • 7

    • SpectralColor:6types• PWSweepSpeed:8increments• Invert:On/Off• M/PWDisplayFormat:V-1/3B,V-1/2B,V-2/3B,H-1/2B,H-1/4B,TLOnly

    • PWAcousticOutput:0–100%, 10%increments

    • SpectralAveraging:5increments pre-settable

    • TimeResolution:4increments• PW/CFRatio:1,2,4• Rejection:15increments• Gain:0–32dB,1dBincrements• WallFilter:5–1,500Hz,22increments:

    probe and application dependent • PWAngleSteer:0+/-10,15,20°• PRF:700–19,800HzwithPW, 2,100–40,000HzwithCW

    • SampleVolumeDepth:29incrementsdefault pre-settable

    • AudioVolume• PWFrequency2–4steps:

    probe dependent

    B-Steer +

    Available on 8L-RS and i12L-RS probes

    Provides clarity to needle, anatomy and motion

    B-Steer + Needle Recognition

    Availableon12L-RS,9L-RSand L8-18i-RS probes

    Provides accurate display of the needle, anatomy and motion even in Color and Power Doppler.

    LOGIQview

    Available on all probes

    Renders a panoramic image up to 60cm,inlongaxis.Italsoallowsyoutosee a wider field of view for comparing normal to abnormal anatomy.

    Virtual Convex

    Available on linear probes

    ProvideswiderFOVinthefarfield

    Virtual Apex

    Available on Sector probes

    ProvideswiderFOVinthenearfield

    Measurements/ CalculationsGeneral Measurements/Calculations Mode Measurement• B-Mode –Distance –Circumference/Area(Ellipse/Trace)• M-Mode –TissueDepth(Distance) –TimeInterval –DepthDifferencewithTimeInterval

    and Slope• DopplerMode –Velocity –TAMAX,TAMIN,andTAMEAN

    (Manual/AutoTrace) –TwoVelocitieswithSlope

    and Time Interval –TimeInterval

    Generic Measurement• B-Mode –%Stenosis –Volume –Angle –A/BRatio• M-Mode –%Stenosis –A/BRatio –HeartRate• DopplerMode –PI(PulsatilityIndex) –RI(ResistiveIndex) –S/DRatio –D/SRatio –A/BRatio –MaxPG(PressureGradient) –MeanPG(PressureGradient) –SV(StrokeVolume) –HeartRate

    Abdomen and Small Parts Measurements/Calculations• Aorta/AAA• Liver• Gallbladder/CBD• Spleen• Bladder(Pre/postvoidvolume)• Renal/RenalVolume• DopplerAbdominaland

    Renal Artery Exam Calcs –Acceleration

    –AccelerationTime(AT) –PeakSystole(PS),EndDiastole(ED),

    orMidDiastole(MD) –PulsatilityIndex(PI) –S/DorD/SRatio –ResistiveIndex(RI) –TAMAX –MaxPG –MeanPG• Emergencymedicine –Aorta –AAA –Gallbladder/GallbladderWall

    Thickness/CBD• Pleural• Testicle –Epididymis• Thyroid/Parathyroid• SalivaryGlands• Breast

    Obstetrics Measurements/ Calculations• Opentrace• AbdominalCircumference(AC)• AmnioticFluidIndex(AFI)[Moore]• Antero-PosteroTrunkDiameter

    and Transverse Trunk Diameter (APTD- TTD)

    • Antero-PosteroTrunkDiameterbyTransverse Trunk Diameter (AxT)

    • BiparietalDiameter(BPD)• CrownRumpLength(CRL)• Cardio-ThoracicAreaRatio(CTAR)• EstimatedFetalWeight(EFW)• FemoralLength(FL)• FootLength(Ft)• GestationalSac(GS)• HeadCircumference(HC)• HumeralLength(HL)• LengthofVertebra(LV)• OccipitofrontalDiameter(OFD)• TransverseAbdominalDiameter(TAD)• TransverseCerebellarDiameter(TCD)• ThoraxTransverseDiameter(ThD)• TibialLength(Tibia)• UlnarLength(Ulna)• Multi-GestationalCalculations –Upto4fetuses –Comparisonofmultiplefetusdata

    on a graph and a worksheet

  • 8

    OB Worksheet• PatientInformation –FetusNumber –CUA/AUASelection –FetusPosition –Placenta• MeasurementInformation –AFI –AC –HC –BPD –FL• CalculationInformation –EFW –EFWGP(growthpercentile) –FL/BPD –FL/AC –HC/AC –FL/HC –CI(CephalicIndex)

    OB Graphs• FetalGrowthCurveGraphs –Normalgrowthcurve,positive

    and negative standard deviations or applicable percentiles, and ultrasound age of the fetus

    –Onemeasurementpergraph –SingleorQuadviews• FetalGrowthBarGraph –Ultrasoundageandgestationalage –Plotsallmeasurementsononegraph

    Gynecology Measurements/ Calculations• OvarianLength,Width,andHeight• UterineLength,Width,andHeight• OvarianFollicleMeasurements –Onedistance –Twodistances –Threedistances• Endometrialthickness(Endo)

    Musculoskeletal Measurements/ Calculations• Shoulder• Elbow• Wrist• Hand• SmallJoint• Hip• Knee

    • LowerLeg• Ankle• Foot

    Cardiac Measurements/Calculations B-Mode Measurements• IMT –Semiautomatedmeasurementfor

    intima-media wall thickness –Allowanteriorandposteriorwall

    thickness measurements. –Displaysminimum,meanand

    maximum results –Measurementscanbetransferred

    to the worksheet or a report• Aorta –AorticArchDiameter(AoArchDiam) –AscendingAorticDiameter(AoAsc) –DescendingAorticDiameter(Ao

    Desc Diam) –AortaIsthmus(AoIsthmus) –Aorta(Aostjunct)• AorticValve –AorticValveCuspSeparation

    (AVCusp) –AorticValveAreaPlanimetry(AVA)

    (TransAVA)• LeftAtrium –LeftAtriumDiameter(LADiam) –LALength(LAMajor) –LAWidth(LAMinor) –LeftAtriumDiametertoAoRoot

    DiameterRatio(LA/AoRatio) –LeftAtriumArea(LAA(d),LAA(s)) –LeftAtriumVolume,MethodofDisk

    (LAEDVA2C,LAESVA2C)(LAEDVA4C,LAESVA4C)

    • LeftVentricle –LeftVentricleMass(LVPWd,LVPWs) –LeftVentricleVolume,Teichholz/

    Cubic(LVIDd,LVIDs) –LeftVentricleInternalDiameter

    (LVIDd,LVIDs) –LeftVentricleLength(LVLd,LVLs) –LeftVentricleOutflowTract

    Diameter(LVOTDiam) –LeftVentriclePosteriorWall

    Thickness(LVPWd,LVPWs) –LeftVentricleLength(LVMajor) –LeftVentricleWidth(LVMinor) –LeftVentricleOutflowTract

    Area(LVOT) –LeftVentricleArea,TwoChamber/

    FourChamber/ShortAxis(LVA(d),LVA(s))

    –LeftVentricleEndocardialArea,Width(LVA(d),LVA(s))

    –LeftVentricleEpicardialArea,Length(LVAepi(d),LVAepi(s))

    –LeftVentricleMassIndex(LVPWd,LVPWs)

    –EjectionFraction,Teichholz/Cube(LVIDd,LVIDs)

    –LeftVentriclePosteriorWall –FractionalShortening(LVPWd,

    LVPWs) –LeftVentricleStrokeIndex,

    Teichholz/Cube(LVIDd,LVIDs, and Body Surface Area)

    –LeftVentricleFractionalShortening(LVIDd,LVIDs)

    –LeftVentricleStrokeVolume, Teichholz/Cubic(LVIDd,LVIDs)

    –LeftVentricleStrokeIndex,SinglePlane,TwoChamber,MethodofDisk(LVIDd,LVIDs)

    –LeftVentricleStrokeIndex,SinglePlane,FourChamber,MethodofDisk(LVIDd,LVIDs)

    –LeftVentricleStrokeIndex,Bi-Plane,Bullet,MethodofDisk(LVAd,LVAs)

    –InterventricularSeptum(IVS) –LeftVentricleInternalDiameter(LVID) –LeftVentriclePosteriorWall

    Thickness(LVPW)• MitralValve –MitralValveAnnulusDiameter(MV

    Ann Diam) –E-Point-to-SeptumSeparation(EPSS) –MitralValveAreabyPressure

    Half Time –MitralValveAreaPlanimetry

    (MVAPlanimetry)• PulmonicValve –PulmonicValveArea(PVPlanimetry) –PulmonicValveAnnulusDiameter

    (PVAnnulusDiam) –PulmonicDiameter(PulmonicDiam)• RightAtrium –RightAtriumDiameter,Length

    (RADMa) –RightAtriumDiameter,Width

    (RADMi) –RightAtriumArea(RAA) –RightAtriumVolume,SinglePlane,

    MethodofDisk(RAAd) –RightAtriumVolume,Systolic,

    SinglePlane,MethodofDisk(RAAs)

  • 9

    • RightVentricle –RightVentricleOutflowTractArea –LeftPulmonaryArteryArea

    (LPA Area) –RightPulmonaryArteryArea

    (RPA Area) –RightVentricleInternalDiameter

    (RVIDd,RVIDs) –RightVentricleDiameter,Length

    (RVDMa) –RightVentricleDiameter,Width

    (RVDMi) –RightVentricleWallThickness

    (RVAWd,RVAWs) –RightVentricleOutflowTract

    Diameter(RVOTDiam) –LeftPulmonaryArtery(LPA) –MainPulmonaryArtery(MPA) –RightPulmonaryArtery(RPA)• System –InterventricularSeptumThickness

    (IVSd,IVSs) –InferiorVenaCava –PulmonaryArteryDiameter(MPA) –SystemicVeinDiameter(Systemic

    Diam) –PatentDuctusArterosisDiameter

    (PDA Diam) –PericardEffusion(PEs) –PatentForamenOvaleDiameter

    (PFO Diam) –VentricularSeptalDefectDiameter

    (VSDDiam) –InterventricularSeptum(IVS) –FractionalShortening(IVSd,IVSs)• TricuspidValve –TricuspidValveArea(TVPlanimetry

    TVAPlanimetry) –TricuspidValveAnnulusDiameter

    (TVAnnulusDiam)

    M-Mode Measurements• Aorta• AorticValve –AorticValveDiameter(AVDiam) –AorticValveCuspSeparation

    (AVCusp) –AorticValveEjectionTime(AVET)• LeftAtrium –LeftAtriumDiametertoAoRoot

    DiameterRatio(LA/AoRatio) –LeftAtriumDiameter(LADiam)• LeftVentricle –LeftVentricleVolume,Teichholz/

    Cubic(LVIDd,LVIDs)

    –LeftVentricleInternalDiameter(LVIDd,LVIDs)

    –LeftVentriclePosteriorWall Thickness(LVPWd,LVPWs)

    –LeftVentricleEjectionTime(LVET) –LeftVentriclePre-EjectionPeriod

    (LVPEP) –InterventricularSeptum(IVS) –LeftVentricleInternalDiameter(LVID) –LeftVentriclePosteriorWall

    Thickness(LVPW)• MitralValve –E-Point-to-SeptumSeparation

    (EPSS) –MitralValveLeafletSeparation

    (D-E Excursion) –MitralValveAnteriorLeaflet

    Excursion (D-E Excursion)• PulmonicValve –QRScomplextoendofenvelope

    (Q-to-PVclose)• RightVentricle –RightVentricleInternalDiameter

    (RVIDd,RVIDs) –RightVentricleWallThickness

    (RVAWd,RVAWs) –RightVentricleEjectionTime(RVET) –RightVentriclePre-EjectionPeriod

    (RVPEP)• System –InterventricularSeptumThickness

    (IVSd,IVSs) –PericardEffusion(PE(d)) –InterventricularSeptum(IVS) –FractionalShortening(IVSd,IVSs)• TricuspidValve –QRScomplextoendofenvelope

    (Q-to-TVclose)

    Doppler Mode Measurements• AorticValve –AorticInsufficiencyMeanPressure

    Gradient (AR Trace) –AorticInsufficiencyEndDiastole

    Pressure Gradient (AR Trace) –AorticInsufficiencyMeanVelocity

    (AR Trace) –AorticInsufficiencyMeanSquare

    RootVelocity(ARTrace) –AorticInsufficiencyVelocityTime

    Integral (AR Trace) –AorticValveMeanVelocity(AVTrace) –AorticValveMeanSquareRoot

    Velocity(AVTrace)

    –AorticValveVelocityTimeIntegral(AVTrace)

    –AorticValveMeanPressureGradient(AVTrace)

    –AorticInsufficiencyEnd-DiastolicVelocity(ARTrace)

    –AorticValvePeakVelocity(AVVmax) –AorticValvePeakVelocityatPointE

    (AVVmax) –AortaProximalCoarctation(Coarc

    Pre-Duct) –AortaDistalCoarctation(Coarc

    Post-Duct) –AorticValveInsufficiencyPressure

    Half Time (AR PHT) –AorticValveFlowAcceleration

    (AVTrace) –AorticValvePressureHalfTime

    (AVTrace) –AorticValveAccelerationTime

    (AVAccTime) –AorticValveDecelerationTIme

    (AVTrace) –AorticValveEjectionTime(AVET) –AorticValveAccelerationtoEjection

    TimeRatio(AVAccTime,AVET)• LeftVentricle –LeftVentricleOutflowTractPeak

    PressureGradient(VLOTVmaxLVOTVmax)

    –LeftVentricleOutflowTractPeakVelocity(LVOTVmax)

    –LeftVentricleOutflowTractMeanPressureGradient(LVOTTrace)

    –LeftVentricleOutflowTractMeanVelocity(LVOTTrace)

    –LeftVentricleOutflowTractMeanSquareRootVelocity(LVOTTrace)

    –LeftVentricleOutflowTractVelocityTimeIntegral(LVOTTrace)

    –LeftVentricleEjectionTime(LVET) –CardiacOutputbyAorticFlow

    (AVAPlanimetry,AVTrace) –StrokeVolumeIndexbyAorticFlow

    (AVAPlanimetry,AVTrace)• MitralValve –MitralValveRegurgitantFlow

    Acceleration(MRTrace) –MitralValveRegurgitantMean

    Velocity(MRTrace) –MitralRegurgitantMeanSquare

    RootVelocity(MRTrace) –MitralRegurgitantMeanPressure

    Gradient(MRTrace) –MitralRegurgitantVelocityTime

  • 10

    Integral(MRTrace) –MitralValveMeanVelocity(MRTrace) –MitralValveMeanSquareRoot

    Velocity(MRTrace) –MitralValveVelocityTimeIntegral

    (MRTrace) –MitralValveMeanPressure

    Gradient(MRTrace) –MitralRegurgitantPeakPressure

    Gradient(MRVmax) –MitralValvePeakPressureGradient

    (MRVmax) –MitralRegurgitantPeakVelocity

    (MRVmax) –MitralValvePeakVelocity

    (MRVmax) –MitralValveVelocityPeakA

    (MVAVelocity) –MitralValveVelocityPeakE

    (MVEVelocity) –MitralValveAreaaccordingtoPHT

    (MVPHT) –MitralValveFlowDeceleration

    (MVTrace) –MitralValveFlowAcceleration

    (MVTrace) –MitralValveE-PeaktoA-PeakRatio

    (A-CandD-E)(MVE/ARatio) –MitralValveAccelerationTime

    (MVAccTime) –MitralValveDecelerationTime

    (MVDecTime) –MitralValveEjectionTime

    (MVTrace) –MitralValveA-WaveDuration

    (MVADur) –MitralValveTimetoPeak(MVTrace) –MitralValveAccelerationTime/

    DecelerationTimeRatio(MVAcc/Dec Time)

    –StrokeVolumeIndexbyMitralFlow(MVAPlanimetry,MVTrace)

    –MitralValveAreafromContinuity Equation(MVAPlanimetry,LVOTVmax)

    • PulmonicValve –PulmonicInsufficiencyPeak

    PressureGradient(PRVmax) –PulmonicInsufficiencyEnd-Diastolic

    Pressure Gradient (PR Trace) –PulmonicValvePeakPressure

    Gradient(PVVmax) –PulmonicEnd-DiastolicPressure

    Gradient (PR Trace) –PulmonicInsufficiencyPeakVelocity

    (PRVmax)

    –PulmonicInsufficiencyEnd-DiastolicVelocity(PRendVmax)

    –PulmonicValvePeakVelocity (PVVmax)

    –PulmonicEnd-DiastolicVelocity (PVTrace)

    –PulmonaryArteryDiastolicPressure(PVTrace)

    –PulmonicInsufficiencyMeanPressureGradient (PR Trace)

    –PulmonicValveMeanPressureGradient(PVTrace)

    –PulmonicInsufficiencyMeanVelocity(PR Trace)

    –PulmonicInsufficiencyMeanSquareRootVelocity(PRTrace)

    –PulmonicInsufficiencyVelocityTimeIntegral (PR Trace)

    –PulmonicValveMeanVelocity (PVTrace)

    –PulmonicValveMeanSquareRootVelocity(PVTrace)

    –PulmonicValveVelocityTimeIntegral(PVTrace)

    –PulmonicInsufficiencyPressureHalf Time (PR PHT)

    –PulmonicValveFlowAcceleration(PVAccTime)

    –PulmonicValveAccelerationTime (PVAccTime)

    –PulmonicValveEjectionTime(PVET) –QRScomplextoendofenvelope

    (Q-to-PVclose) –PulmonicValveAccelerationto

    EjectionTImeRatio(PVAccTime,PVET)

    –PulmonicValvePre-Ejectionto EjectionTimeRatio(PVET)

    • RightVentricle –RightVentricleOutflowTractPeak

    PressureGradient(RVOTVmax) –RightVentricleSystolicPressure

    (RVOTVmax) –RightVentricleOutflowTractPeak

    Velocity(RVOTVmax) –RightVentricleDiastolicPressure

    (RVOTTrace) –RightVentricleOutflowTractVelocity

    TimeIntegral(RVOTTrace) –StrokeVolumebyPulmonicFlow

    (RVOTTrace) –RightVentricleStrokeVolumeIndex

    byPulmonicFlow(RVOTPlanimetry,RVOTTrace)

    • System –PulmonaryArteryPeakVelocity

    (PVVmax) –PulmonaryVeinVelocityPeakA

    (reverse)(PVeinA) –PulmonaryVeinPeakVelocity(P

    VeinD,PVeinS) –SystemicVeinPeakVelocity(PDA

    Diastolic, PDA Systolic) –VentricularSeptalDefectPeak

    Velocity(VSDVmax) –PulmonaryArteryVelocityTime

    Integral(PVTrace) –PulmonaryVeinA-WaveDuration

    (PVeinADur) –IsoVolumetricRelaxationTime(IVRT) –IsoVolumetricContractionTime

    (IVCT) –PulmonaryVeinS/DRatio(PVeinD,

    PVeinS) –VentricularSeptalDefectPeak

    PressureGradient(VSDVmax) –Pulmonic-to-SystemicFlowRatio

    (Qp/Qs)• TricuspidValve –TricuspidRegurgitantPeakPressure

    Gradient(TRVmax) –TricuspidValvePeakPressure

    Gradient(TVVmax) –TricuspidRegurgitantPeakVelocity

    (TRVmax) –TricuspidValvePeakVelocity

    (TVVmax) –TricuspidValveVelocityPeakA

    (TVAVelocity) –TricuspidValveVelocityPeakE

    (TVEVelocity) –TricuspidRegurgitantMean

    Pressure Gradient (TR Trace) –TricuspidValveMeanPressure

    Gradient(TVTrace) –TricuspidRegurgitantMeanVelocity

    (TR Trace) –TricuspidRegurgitantMeanSquare

    RootVelocity(TRTrace) –TricuspidRegurgitantVelocityTime

    Integral (TR Trace) –TricuspidValveMeanVelocity

    (TVTrace) –TricuspidValveMeanSquareRoot

    Velocity(TVTrace) –TricuspidValveVelocityTime

    Integral(TVTrace) –TricuspidValveTimetoPeak

    (TVAcc/DecTime)

  • 11

    –TricuspidValveEjectionTime (TVAcc/DecTime)

    –TricuspidValveA-WaveDuration(TVADur)

    –QRScomplextoendofenvelope(Q-to-TVclose)

    –TricuspidValvePressureHalfTime(TVPHT)

    –StrokeVolumebyTricuspidFlow (TVTrace)

    –TricuspidValveE-PeaktoA-PeakRatio(TVE/AVelocity)

    Color Flow Mode Measurements• AorticValve –ProximalIsovelocitySurfaceArea:

    Regurgitant Orifice Area (AR Radius) –ProximalIsovelocitySurfaceArea:

    Radius of Aliased Point (AR Radius) –ProximalIsovelocitySurfaceArea:

    Regurgitant Flow (AR Trace) –ProximalIsovelocitySurfaceArea:

    RegurgitantVolumeFlow(ARTrace) –ProximalIsovelocitySurfaceArea:

    AliasedVelocity(ARVmax)• MitralValve –ProximalIsovelocitySurfaceArea:

    RegurgitantOrificeArea(MRRadius) –ProximalIsovelocitySurfaceArea:

    RadiusofAliasedPoint(MRRadius) –ProximalIsovelocitySurfaceArea:

    RegurgitantFlow(MRTrace) –ProximalIsovelocitySurfaceArea:

    RegurgitantVolumeFlow(MRTrace) –ProximalIsovelocitySurfaceArea:

    AliasedVelocity(MRVmax) –CombinationModeMeasurements• AorticValve –AorticValveArea(AoRootDiam,

    LVOTVmax,AVVmax) –AorticValveAreabyContinuity

    EquationbyPeakVelocity(AoRootDiam,LVOTVmax,AVVmax)

    –StrokeVolumebyAorticFlow(AVA)Planimetry,AVTrace)

    –CardiacOutputbyAorticFlow(AVAPlanimetry,AVTrace,HR)

    –AorticValveAreabyContinuityEquationVTI(AoRootDiam,LVOTVmax,AVTrace)

    • LeftVentricle –CardiacOutput,Teichholz/Cubic

    (LVIDd,LVIDs,HR)

    –CardiacOutputTwoChamber,SinglePlane,Area-Length/Method ofDisk(Simpson)(LVAd,LVAs,HR)

    –CardiacOutputFourChamber,SinglePlane,Area-Length/MethodofDisk(Simpson)(LVAd,LVAs,HR)

    –EjectionFractionTwoChamber,SinglePlane,Area-Length/MethodofDisk(Simpson)(LVAd,LVAs)

    –EjectionFractionFourChamber,SinglePlane,Area-Length/MethodofDisk(Simpson)(LVAd,LVAs)

    –LeftVentricleStrokeVolume,SinglePlane,TwoChamber/FourChamber,Area-Length(LVAd,LVAs)

    –LeftVentricleStrokeVolume,SinglePlane,TwoChamber/FourChamber,MethodofDisk(Simpson)(LVIDd,LVIDs,LVAd,LVAs)

    –LeftVentricleVolume,Two Chamber/FourChamber, Area-Length(LVAd,LVAs)

    –EjectionFraction,Bi-Plane,MethodofDisk(LVAd,LVAs,2CH,4CH)

    –LeftVentricleStrokeVolume, Bi-Plane,MethodofDisk(LVAd, LVAs,2CH,4CH)

    –LeftVentricleVolume,Bi-Plane,MethodofDisk(LVAd,LVAs,2CH,4CH)

    –LeftVentricleStrokeIndex,SinglePlane,TwoChamber/FourChamber,Area-Length(LVSd,LVSs,andBSA)

    –LeftVentricleVolume,SinglePlane,TwoChamber/FourChamber,MethodofDisk(LVAd,LVAs)

    –LeftVentricleVolume,ApicalView,LongAxis,MethodofDisk(LVAd,LVAs)

    –StrokeVolumebyAorticFlow (AVAPlanimetry,AVTrace)

    • MitralValve –StrokeVolumebyMitralFlow

    (MVAPlanimetry,MVTrace) –CardiacOutputbyMitralFlow

    (MVAPlanimetry,MVTrace,HR)• PulmonicValve –StrokeVolumebyPulmonicFlow

    (PVPlanimetry,PVTrace) –CardiacOutputbyPulmonicFlow

    (PVPlanimetry,PVTrace,HR)• TricuspidValve –CardiacOutputbyTricuspidFlow

    (TVPlanimetry,TVTrace,HR)

    Vascular Measurements/ Calculations Exam Categories• Generic• CarotidArteryIMT• LowerExtremityArtery• LowerExtremityVein• RenalArtery• UpperExtremityArtery• UpperExtremityVein

    B-Mode Measurements• IMT –Semiautomatedmeasurement

    for intimal-media wall thickness –Allowanteriorandposteriorwall

    thickness measurements. –Displaysminimum,meanand

    maximum results. –Measurementscanbetransferred

    to the worksheet or a report.• %Stenosis –Diameter –Area• Volume –Onedistance –Twodistances –Threedistances• A/BRatio –Diameter –Area

    M-Mode Measurements• %Stenosis –Diameter• A/BRatio –Diameter –Time –Velocity

    Doppler Mode Measurements Auto Vascular Calculation • Acceleration• AccelerationTime(AT)• EndDiastole(ED),MidDiastole(MD),

    or Peak Systole (PS)• ED/PSorPS/EDRatio• HeartRate• PulsatilityIndex(PI)• ResistiveIndex(RI)• TAMAX• EditTrace• TAMEAN• VolumeFlow• PV

  • 12

    Vascular Worksheet • VesselWorksheet• VesselSummary• Examiner’sComments• GenericWorksheet• IntravesselRatio

    Pediatrics Measurements/ Calculations• AlphaHIP• d:DRatio• HIP(BA)• HIPGraf(A/AB/BA)

    Urology Measurements/ Calculations• Bladder(0.7)Length,Height,WidthandVolume

    • Prostate(0.7523)Length,Height,WidthandVolume

    • RenalLength(0.49),Height,WidthandVolume

    • STVOL

    Probes• 4C-RSWideBandConvexProbe –Applications:Abdomen,OBGyn,

    Urology,Thoracic/Pleural,Hip –ImagingFrequency:2.0-5.5MHz –NumberofElements:128 –ConvexRadius:60mmR –FOV:55° –Footprint:18.3x66.2mm –B-ModeImagingFrequency:

    2.0,3.0,4.0,5.0MHz –HarmonicImagingFrequency:

    4.0,5.0,5.2,5.5Mhz –CFMImagingFrequency:2.5,3.3Mhz –DopplerFrequency:2.5,3.3MHz –BiopsyGuide:ReusableBracket,

    Disposable Sleeve –MaximumFrameRate:1,146Hz• 8C-RSWideBandMicroconvexProbe –Applications:Pediatrics –ImagingFrequency:4.0–10.0MHz –NumberofElements:128 –ConvexRadius:11mmR –FOV:133° –Footprint:12x22mm –B-ModeImagingFrequency:

    6.0,8.0,10.0MHz –HarmonicImagingFrequency:

    8.0,9.0,10.0MHz

    –CFMImagingFrequency:4.0,5.0MHz –DopplerFrequency:4.0,5.0MHz –BiopsyGuideNotAvailable –MaximumFrameRate:1,206Hz• E8C-RSWideBandMicro-convex

    Probe –Applications:OB,Gyn,Urology,

    Endocavity –ImagingFrequency:4.0–10.0MHz –NumberofElements:128 –ConvexRadius:11mmR –FOV:133° –Footprint:16.9x21.2mm –B-ModeImagingFrequency:

    6.0,8.0,10.0MHz –HarmonicImagingFrequency:

    8.0,10.0MHz –CFMImagingFrequency:4.0,5.0MHz –DopplerFrequency:4.0,5.0MHz –BiopsyGuide:FixedAngle;Reusable

    Bracket, Disposable Sleeve –MaximumFrameRate:1,972Hz• 3S-RSWideBandPhasedArrayProbe –Applications:Cardiac,Abdomen,

    Gyn,Thoracic/Pleural,Vascular –ImagingFrequency:1.7–4.0MHz –NumberofElements:64 –FOV:90° –Footprint:19.3x27.6mm –B-ModeImagingFrequency:

    2.0,2.5,3.0MHz –HarmonicImagingFrequency:

    2.8,3.0,3.2,3.6,3.8,4.0MHz –CFMImagingFrequency:1.7,2.0,

    2.2,2.6MHz –DopplerFrequency:1.7,2.0,2.2,

    2.6MHz –BiopsyGuide:MultiAngle;Reusable

    Bracket, Disposable Sleeve –MaximumFrameRate:463Hz• 6S-RSWideBandPhasedArrayProbe –Applications:PediatricCardiac,

    Pediatric Abdomen –ImagingFrequency:2.5–7.0MHz –NumberofElements:64 –FOV:90° –Footprint:16.8x23.5mm –B-ModeImagingFrequency:

    3.0,4.0,5.0,6.0MHz –HarmonicImagingFrequency:

    5,6,7MHz –CFMImagingFrequency:

    2.5,2.9,3.3,4.0MHz

    –DopplerFrequency: 2.5,2.9,3.3,4.0MHz

    –BiopsyGuideNotAvailable –MaximumFrameRate:695Hz• L8-18i-RSWideBandLinearProbe –Applications:Vascular,Smallparts,

    Pediatric/Neonatal,Vascular Access, Anesthesia, Point of Care, InterventionalandMusculoskeletal

    –ImagingFrequency:6.7-18.0MHz –NumberofElements:168 –FOV(max):25.2mm –Footprint11.1x34.8mm –B-ModeImagingFrequency:8.0,

    12.0,14.0,16.0MHz –HarmonicImagingFrequency:9.0,

    12.0,15.0,18.0MHz –CFMModeImagingFrequency:6.7,

    8.0,10.0MHz,definedbyapplication –DopplerFrequency:6.7,8.0,10.0MHz –SteeredAngle:+/-20 –BiopsyGuideNotAvailable –MaximumFrameRate:151Hz• 8L-RSWideBandLinearProbe –Applications:Vascular,SmallParts –ImagingFrequency:4.0–12.0MHz –NumberofElements:128 –FOV(max):39mm –Footprint:14.2x47mm –B-ModeImagingFrequency:

    6.0,7.0,8.0,10.0,11.0MHz –HarmonicImagingFrequency:

    6.0,8.0,10.0,11.0,12.0MHz –CFMImagingFrequency:4.0,4.4,

    5.0MHz –DopplerFrequency:4.0,4.4,5.0MHz –SteeredAngle:+/-20° –BiopsyGuide:MultiAngle;Reusable

    Bracket, Disposable Sleeve –MaximumFrameRate:251Hz• 9L-RSWideBandLinearProbe –Applications:Vascular,SmallParts,

    MSK –ImagingFrequency:3.33–10.0MHz –NumberofElements:192 –FOV(max):44mm –Footprint:14.1x53mm –B-ModeImagingFrequency:

    5.0,7.0,9.0MHz –HarmonicImagingFrequency:

    8.0,10.0MHz

  • 13

    –CFMImagingFrequency:3.33,4.0,5.0MHz

    –DopplerFrequency:3.33,4.0,5.0MHz –SteeredAngle:+/-20° –BiopsyGuide:MultiAngle;Reusable

    Bracket, Disposable Sleeve –MaximumFrameRate:84Hz• 12L-RSWideBandLinearProbe –Applications:Vascular,SmallParts,

    Neonatal,Pediatrics,Musculoskeletal,Superficial,andThoracic/Pleural

    –ImagingFrequency:5.0–13.0MHz –NumberofElements:192 –FOV(max):39mm –Footprint:12.7x47.1mm –B-ModeImagingFrequency:

    7.0,8.0,10.0,12.0MHz –HarmonicImagingFrequency:

    8.0,10.0,12.0,13.0MHz –CFMImagingFrequency:5.0,6.7,

    8.0MHz –DopplerFrequency:5.0,6.7,8.0MHz –SteeredAngle:+/-20° –BiopsyGuideMultiAngleand

    Out-of-Plane;ReusableBracket,Disposable Sleeve

    –MaximumFrameRate:106Hz• i12L-RSWideBandLinearProbe –Applications:Vascular,SmallParts,

    Intra-operative –ImagingFrequency:4.0–10.0MHz –NumberofElements:96 –FOV(max):25mm –Footprint:12.2x32mm –B-ModeImagingFrequency:

    6.0,8.0,10.0MHz –HarmonicImagingFrequency:

    8.0,10.0MHz –CFMImagingFrequency:

    4.0,5.0MHz –DopplerFrequency:4.0,5.0MHz –SteeredAngle:+/-20° –BiopsyGuideNotAvailable –MaximumFrameRate:251Hz• i/T739-RSWideBandLinearProbe –Applications:Vascular,SmallParts,

    Intra-operative –ImagingFrequency:4.0–12.0MHz –NumberofElements:96

    –FOV(max):39mm –Footprint:14x48mm –B-ModeImagingFrequency:

    6.0,8.0,10.0MHz –HarmonicImagingFrequency:8.0,

    10.0,12.0MHz –CFMImagingFrequency:4.0,4.4,

    5.0MHz –DopplerFrequency:4.0,4.4,5.0MHz –SteeredAngle:+/-10°,+/-15° –BiopsyGuideNotAvailable –MaximumFrameRate:251Hz• 6Tc-RSTEEProbe –Applications:Cardiacintra-operative –ImagingFrequency:3.3-6.0MHz –NumberofElements:64 –B-ModeImagingFrequency:

    4.0,5.0MHz –HarmonicImagingFrequency:

    4.0,6.0MHz –CFMImagingFrequency:

    3.3,4.0,5.0MHz –DopplerFrequency:3.3,4.0,5.0MHz –CWDFrequency:4.0MHz –BiopsyGuideNotAvailable• P2DNon-imagingProbe –Applications:Cardiac,Vascular –Footprint:13.6mm –CWDFrequency:2.0MHz –BiopsyGuideNotAvailable

    Inputs and Outputs• Outputs –VGAEarphone Port• Connectors –USB(Footswitch,DVD-RW,

    video printer) –DCPowerinput –Ethernetport –DockingConnector

    Safety Conformance

    LOGIQ e is:• ListedtoUL60601-1byaNationally

    Recognized Test Lab • CertifiedtoCAN/CSA-C22.2No.601.1

    by an SCC accredited Test Lab• CEMarkedtoCouncilDirective93/42/EEConMedicalDevices

    • Conformstothefollowingstandardsfor safety:

    –IEC60601-1Electrical medical equipment

    –IEC60601-1-1Electrical medical equipment

    –IEC60601-1-2Electromagneticcompatibility

    –IEC60601-1-4Programmablemedical systems

    –IEC60601-1-62004Medical ElectricalEquipment—Part6: General Requirements for safety—Usability

    –IEC61157Declarationof acoustic output

    –IEC60601-2-37:Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment

    –ISO10993Biologicalevaluation of medical devices

    –NEMAUD3Acousticoutputdisplay(MI,TIS,TIB,TIC)

    Not all features or specifications described in this document may be availableinallprobesand/ormodes.General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue the product at any time without notice or obligation. Contact your GE Representative for the most current information.

  • GE Healthcare 9900InnovationDrive Wauwatosa,WI53226 U.S.A. 8885265144

    www.gehealthcare.com

    imagination at workULTP-0536-03.12-EN.US DOC0931486

    ©2012GeneralElectricCompany–Allrightsreserved.

    General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation.

    *GE,GEMonogram,LOGIQ,andCrossXBeamaretrademarks of General Electric Company.

    GEMedicalSystemsUltrasound&PrimaryCareDiagnostics,LLC, a General Electric Company, doing business as GE Healthcare.

    About GE Healthcare GE Healthcare provides transformational medical technologies and services that are shaping a new age of patient care. Our broad expertise in medical imaging and information technologies, medical diagnostics, patient monitoring systems, drug discovery, biopharmaceutical manufacturing technologies, performance improvement and performance solutions services helps our customers to deliver better care to more people around the world at a lower cost. In addition, we partner with healthcare leaders, striving to leverage the global policy change necessary to implement a successful shift to sustainable healthcare systems.Our“healthymagination”visionforthefutureinvitestheworldtojoinusonourjourney as we continuously develop innovations focused on reducing costs, increasing access, and improvingqualityaroundtheworld.HeadquarteredintheUnitedKingdom,GEHealthcareisaunitofGeneralElectricCompany(NYSE:GE).Worldwide,GEHealthcareemployeesarecommittedtoservinghealthcareprofessionalsandtheirpatientsinmorethan100countries.For more information about GE Healthcare, visit our website at www.gehealthcare.com

    Europe GE Healthcare Beethovenstr.239 D-42655Solingen T4921228020 F49212280228

    Asia GE Healthcare Clinical Systems ASIA 1105-1108MaxdoCenter 8XingYiRoad,Shanghai 200336 T862152574640 F862152080582