38
1 GENERAL CATALOGUE

Lock Catalog

Embed Size (px)

Citation preview

Page 1: Lock Catalog

1

GENERALCATALOGUE

Page 2: Lock Catalog

2

Openers & Closers was founded in Barcelona in 1989, with the aim of manufacturing quality door locks and ensuring an efficient customer service.

After 20 years of experience, O&C is one of the leading European manufactu-rers of electric strikes and electromagnetic locks, exporting approximately 90% of production in over 40 different countries.

Such achievement is probably the result of the company’s policy of constantly improving product quality while maintaining an affordable price, in combi-nation with the staff engagement to educate, update and advise clients on a regular basis.

O&C currently owns over 30 patents for technical and production innovations, entirely designed and manufactured in Spain. All our products have been tes-ted by APPLUS+ Norcontrol and LGAI Technological Center.

Nevertheless, higher quality means lower energy consumption and less waste generation thanks to longer product life. As a matter of fact, our products are guaranteed from 3 to 5 years. Our commitment to the environment is also wit-nessed by our respect of the RoHS.

OPENERS & CLOSERS: INNOVATION, QUALITY & SERVICE.

Page 3: Lock Catalog

BASIC for door entry systemsSYMMETRICAL for door entry systems

SECURITY for access control systems

SECURITY with electronic coil

EMERGENCY for push bar locks

MINI for aluminum, wood & PVC doors

WATERPROOF for outdoor applications

ARMOURED for multibolt locks

FIRE for RF-120 doors

HIGH-SECURITY for access control systems & heavy-duty doors

new

new

ELECTRIC STRIKES

Page 4: Lock Catalog

22

BASIC FOR DOOR ENTRY SYSTEMS

Dimensions

Operation

Coil features

Technical features

Adjustable latch

symmetrical reversibility with DIN Right and Left

Fail-secure Hold-open Internal Hold-openwith mechanicalunlatching

with mechanicalunlatching

with mechanicalunlatching

asymmetrical reversibilitywith DIN Left

Hold-open

opened closed opened closed

Internal Hold-open

References and features

Fixed latch

Fixed latch

Fail-secure

Fail-secure with mechanical unlatching

Hold-open

Hold-open with mechanical unlatching

Internal Hold-open

Internal Hold-open with mechanical unlatching

The electric strike is locked when unenergized.

It works just like the Fail-secure model but with mechanical release function.

The electric strike has a device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.

It works just like the Hold-open model but with mechanical release function.

The electric strike has an internal device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.

It works just like the Internal Hold-open but with mechanical release function.

Adjustablelatch Preload Voltage References

DIN rightadd faceplate

ReferencesDIN leftadd faceplate

8-14 V ac/dc

8-14 V ac/dc

8-14 V ac/dc

8-14 V ac/dc

8-14 V ac/dc

8-14 V ac/dc

8-14 V ac/dc

8-14 V ac/dc

9-14 V ac/dc

9-14 V ac/dc

9-14 V ac/dc

9-14 V ac/dc

5-12 V ac/dc

5-12 V ac/dc

5-12 V ac/dc

5-12 V ac/dc

5-12 V ac/dc

5-12 V ac/dc

6-12 V ac/dc

6-12 V ac/dc

5-12 V ac/dc

5-12 V ac/dc

6-12 V ac/dc

6-12 V ac/dc

12 V dc

12 V dc

12 V dc

12 V dc

24 V dc

24 V dc

24 V dc

24 V dc

10.0.00.B

11.0.00.B

20.0.00.B

21.0.00.B

10.0.00.J

11.0.00.J

20.0.00.J

21.0.00.J

10.0.00.E

11.0.00.E

20.0.00.E

21.0.00.E

10.0.00.F

11.0.00.F

20.0.00.F

21.0.00.F

10.1.00.B

11.1.00.B

12.0.00.B

13.0.00.B

20.1.00.B

21.1.00.B

22.0.00.B

23.0.00.B

10.1.00.J

11.1.00.J

12.0.00.J

13.0.00.J

12A.0.00.J

13A.0.00.J

12A.0.00.B

13A.0.00.B

20.1.00.J

21.1.00.J

22.0.00.J

23.0.00.J

22A.0.00.B

23A.0.00.B

22A.0.00.J

23A.0.00.J

10.1.00.E

11.1.00.E

12.1.00.B

13.1.00.B

12A.1.00.B

13A.1.00.B

20.1.00.E

21.1.00.E

22.1.00.B

23.1.00.B

22A.1.00.B

23A.1.00.B

10.1.00.F

11.1.00.F

12.1.00.J

13.1.00.J

12A.1.00.J

13A.1.00.J

20.1.00.F

21.1.00.F

22.1.00.J

23.1.00.J

22A.1.00.J

23A.1.00.J

105

°C

Minutes 5(a 12 Vac)

(12 Ω 0,7 A a 12 Vac) 8/14 V ac/dcB

65

°C

Minutes 5(a 9 Vac)

(8 Ω 0,6 A a 9 Vac) 5/12 V ac/dcJ

53

°C

Hours 5

(60 Ω 0,20 A) 12 Vdc 100%E

77

°C

Hours 5

(220 Ω 0,12 A) 24 Vdc 100%F

Warning:

When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.

Incorrect installation could cause door-release failure.

Temperature test:

Measured on coil surface, tolerance ±10%

Other coils and voltages on demand

Electric strikes with «ac» coils work properly even with a pressure up to 16Kg

300.000 guaranteed openings

Withstands impacts up to 300 Kg

Steel screws

Low power consumption

Corrosion resistant according to UNI ISO 9227 Standards

Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).

90

28

33,5

46,821

9,7

11

52,3

Page 5: Lock Catalog

3

FACEPLATES25

159

3

52

44

48,5

47,2

563,2

5

GREY

INOX 3mm GREY GREY

01

61 80 81

32,7

548,5

22,7

5 104

3

52

44

48,5

36

104,5

23

47,5

52

25,5

Reversible

Right

Right

Left

Left

DIN

DIN

Reversible Reversible

GREY/BROWN

INOX 3mm

03 05 04

63 65 64

D5 D4

D65 D64

C5 C4

C65 C64

D3

D63

C3

C63

Reversible Reversible

25

61,7

548,5

139,7

5

12

79

35

44

250

3

52

25

61,7

548,5

139,7

5

102

12,544

250

12

3

52

25

61,7

548,5

139,7

5 17

44

12,5

102

250

3

52

Adjustable latch (3mm)

3,2

5

Deep latch installation example Ref. 3

Fixed latch Ref. 012,7

8,2543,6

46,5

16

Standard adjustable latch Ref. 146,2

43,2

16,5

7,75

12,7

Shallow adjustable latch Ref. 2Supplied on demand

46,2

43,2

16,5

6,15

12,7

Deep adjustable latch Ref. 3Supplied on demand

46,2

43,2

16,5

13,3

12,7

90,4

21,3

52

9,4

33,47 ESP2

34

64

48

128

14

90

124

4

240

2

52

INOX 3mm

INOX 2mm

73

20

74

21

2

250

48

80

122

25

44

36

80

14

52

Page 6: Lock Catalog

4

Door Handedness

DIN definition:The door is viewed from the side on which the hinges are visible.

DIN Left DIN Right DIN Left DIN Right

14552

36,5

25

106,9

GREY

CHROME

BRASS

84

84

84

Reversible

Reversible Reversible

BROWN BROWN

16 17

52

12

R10 R

10

R10

R10

44

52

R10 R

10

R10

R10

Right LeftDIN

79

250

250

2

32

25

35

250

2

25 32

44

35

79

12

Right LeftDIN

BROWN10 11 BROWN14 15

R10

R10

R 10 R 10

52

12

R10 R

10

R 10R 10

52

12

Right LeftDIN

BROWN12 13

12

102

44

250

32 25

2

250

44

12

102

48,5

2

32

25

Right LeftDIN

BROWN08 09

R10

R 10R 10

R10

52

48,5

25

32

44

172

FACEPLATES

Page 7: Lock Catalog

5

References and featuresReversible

Fail-secure

Fail-Secure with mechanical unlatching

Hold-open

Hold-open with mechanical unlatching

Internal Hold-open

Internal Hold-open with mechanical unlatching

The electric strike is locked when unenergized.

It works just like the Fail-secure model but with mechanical release function.

The electric strike has a device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.

It works just like the Hold-open model but with mechanical release function.

The electric strike has an internal device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.

It works just like the Internal Hold-open but with mechanical release function.

Adjustablelatch Preload Electronic

protection Voltage Referenceslatch (1)add faceplate

8-14 V ac/dc

8-14 V ac/dc

8-14 V ac/dc

8-14 V ac/dc

9-14 V ac/dc

9-14 V ac/dc

5-12 V ac/dc

5-12 V ac/dc

5-12 V ac/dc

5-12 V ac/dc

6-12 V ac/dc

6-12 V ac/dc

12 V dc

12 V dc

24 V dc

24 V dc

30.1.00.B

31.1.00.B

32.1.00.B

30.1.00.J

31.1.00.J

32.1.00.J

30.1.00.E

31.1.00.E

30.1.00.F

31.1.00.F

33.1.00.B

33.1.00.J

32A.1.00.B

33A.1.00.B

32A.1.00.J

33A.1.00.J

Coil features

Operation Dimensions

Fail-secure Fail-secure Hold-open

Opened Closed

Hold-open Internal Hold-open Internal Hold-open Fail-safe

Technical features

105

°C

Minutes 5(a 12 Vac)

(14 Ω 0,7 A a 12 Vac) 8/14 V ac/dcB

65

°C

Minutes 5(a 9 Vac)

(8 Ω 0,6 A a 9 Vac) 5/12 V ac/dcJ

Electric strikes with «ac» coils work properly even with a pressure up to 16Kg.

300.000 guaranteed openings

Withstands impacts up to 280 Kg.

Steel screws

Low power consumption

Corrosion resistant according to UNI ISO 9227 Standards

Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).

21

69

12

12

29

52

10

11

Warning:

When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.

Incorrect installation could cause door-release failure.

Temperature test:

Measured on coil surface, tolerance ±10%

Internal hold-open

53

°C

Hours 5

(50 Ω 0,25 A) 12 Vdc 100%E

77

°C

Hours 5

(185 Ω 0,12 A) 24 Vdc 100%F

Other coils and voltages on demand

Fail-safeThe electric strike is locked when energized.

12 V dc

24 V dc

34.1.00.E

34.1.00.F

with mechanicalunlatching

with mechanicalunlatching

with mechanicalunlatching

SYMMETRIC FOR DOOR ENTRY SYSTEMS

Page 8: Lock Catalog

6

GREY/BROWN

INOX 3mm

03 05 04

63 65 64

D5 D4

D65 D64

C5 C4

C65 C64

D3

D63

C3

C63

Reversible Reversible

25

61,7

548,5

139,7

5

12

79

35

44

250

3

52

25

61,7

548,5

139,7

5

102

12,544

250

12

3

52

25

61,7

548,5

139,7

5 17

44

12,5

102

250

3

52

25

30,7

548,5

30,7

5

44

110

3

52

GREY

INOX 3mm

02

62

Reversible

Right LeftDIN

INOX 3mm73 74

52

34

64

48

128

14

90

124

4

240

2

INOX 2mm20 21

2

250

48

80

122

25

44

36

80

14

Right LeftDIN

52

Adjustable latch (3mm)

Deep latch installation example Ref. 3

Standard adjustable latch Ref. 1

Deep adjustable latch Ref. 3Supplied on demand

ESP3

21,369,3

52

12

12

5,5

3

44,7

11,6

14,7

47,1

44,7

11,6

14,7

47,1

5,4

13,5

FACEPLATES25

159

3

52

44

48,5

47,2

563,2

5

GREY

INOX 3mm

01

61

Reversible

Page 9: Lock Catalog

7

14552

36,5

25

106,9

GREY

CHROME

BRASS

84

84

84

Reversible12

102

44

250

32 25

2

250

44

12

102

48,5

2

32

25

R10

R10

R 10 R 10

52

12

R10 R

10

R 10R 10

52

12

Right RightLeft LeftDIN DIN

BROWN BROWN08 1209 13

Door Handedness

DIN definition:The door is viewed from the side on which the hinges are visible.

DIN Left DIN Right DIN Left DIN Right

Reversible ReversibleBROWN BROWN16 17

R10

R 10R 10

R10

52

48,5

25

32

44

172

FACEPLATES

Page 10: Lock Catalog

8

Coil features

Technical featuresReinforced mechanism box

Stainless steel lock cover

Steel latch and screws

Electric strikes with 12V ac coils are released by applying a pressure up to 16 kgWithstands impacts and pressures up to 500 Kg, getting destroyed at 700kg.

300.000 guaranteed openings Low power consumption

Corrosion resistant according to UNI ISO 9227 Standards

Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).Latch adjustment regulator (is supplied on demand)

°C

Minutes 5(a 12 Vac)

(20 Ω 0,5 A a 12 Vac) 8/14 V ac/dcL

6266

°C

Hours 5

(70 Ω 0,17A) 12 Vdc 100%M

°C

Hours 5

(240 Ω 0,10A) 24 Vdc 100%N

57

°C

Hours 5

(54 Ω 0,22 A) 2 microswitch 12 Vdc 100%P

Warning:

When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.

Incorrect installation could cause door-release failure.

Temperature test:

Measured on coil surface, tolerance ±10%

62

5156

FAIL-SAFE

FAIL-SECURE

References and featuresFixed latch

Fail-secure

Fail-secure with 1 microswitch

Fail-secure with 2 microswitch

Internal Hold-open

Fail-safe

Fail-safe with 1 microswitch

Fail-safe with 2 microswitch

The electric strike is locked when unenergized.

It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.

It works just like the Fail-secure model plus 2 electrical switching device that detects the status of the electric strike and the door.

The electric strike has an internal device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door.

The electric strike is locked when energized.

It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.

It works just like the Fail-safe model plus 2 electrical switching device that detects the status of the electric strike and the door.

Electronic protectionPreload Voltage

ReferencesDIN leftadd faceplate

ReferencesDIN rightadd faceplate

8-14 V ac/dc

8-14 V ac/dc

9-14 V ac/dc

12 V dc

12 V dc

12 V dc

12 V dc

24 V dc

24 V dc

12 V dc

12 V dc

24 V dc

24 V dc

24 V dc

24 V dc

4L0.4.00.L

4L6.4.00.L

4L6.4.00.M

4L4.4.00.M

4L6.4.00.N

4L4.4.00.N

4R0.4.00.L

4R6.4.00.L

4R6.4.00.M

4R4.4.00.M

4R6.4.00.N

4R4.4.00.N

47.4.00.P

47.4.00.N

4L0.4.00.M4R0.4.00.M

4L0.4.00.N4R0.4.00.N

4L8.4.00.M4R8.4.00.M

4L8.4.00.N4R8.4.00.N

49.4.00.P

49.4.00.N

4L2A.4.00.L4R2A.4.00.L

Fail-secure Internal Hold-open OperationFail-safe 1 microswitch 2 microswitch

D D D D DI I I I I opened closedasymmetrical reversibility

Interconnection between principal and secondary microswitch

Schematic electric diagram

Push button Push button

Light Light

Secondarymicroswitch

S2

Principal microswitch S1

Principal microswitch S1

Power supply Power supply

Door openedDoor opened

Unlocked lever(electric strike open)

Door closedDoor closed

Common

Connection

Door released and lever unlocked

Door closed and lever lockedDoor released

Electric connection

Unlocked lever connection

Locked lever connectionCommon

Electric connection

Door closed connection

Door released connectionPrincipal microswitch S1

Secondary microswitch S2

Common

Principal microswitch S1 Secondary microswitch S2

Intensity 1A/125 Vac0,5A/30 Vdc

0,5A/30 Vdc

Operating speed 1 at 500 mm/second (at pin plunger) 1 at 500 mm/second (at pin plunger)

Operating frecuency Mechanical: 200 operations per minute Electrical: 30 operations per minute

Mecánica: 200 operations per minute Eléctrica: 30 operations per minute

Contact resistance Standard type: 30 mΩ max. Standard type: 30 mΩ max.

Ambient temperature From -25°C a 65°C (without ice) From -25°C a 70°C (without ice)

Humidity 85% RH max. (5° a 35°C) 85% RH max. (5° a 35°C)

Life expectancy Mechanical: 300.000 operations min.Electrical: 30.000 operations min.

Mechanical: 30.000 operations min.Electrical: 30.000 operations min.

Fail-secure Fail-safe Fail-secure Fail-safe

Fail-secure Fail-safe

openedclosed

Other coils and voltages on demand

FAIL-SAFE

FAIL-SECURE

SECURITY FOR ACCESS CONTROL SYSTEMS

Page 11: Lock Catalog

9

References and features

Door access control with two ac/dc power supplies

Applications

Dimensions

Digital installations of telephone and video intercoms are generally equipped with batteries to supply the system in cases of power cuts.

When an access control system is working on:

«ac» current: the electric strike opens with a pressure of up to 16 kg on the latch and the coil emits the standard «ac» buzzing sound.«dc» current (from the batteries): the electric strike does not open under pressure and emits no sound. important notice: «dc» current does not admit pressure during electromagnetic release.

Security electric strikes with vibrating ac/dc electronic coil are suitable for all digital telephone and video intercom installations.

The electronic coil is activated whether it is working in «ac/dc» current, the standard buzzing signal is always emitted and the door release will open at any time under a pressure up to 14 kg.

Important notice: It should be noted that the electrical connections of the electronic coil are not polarized, so it should be connected in the same way as a fail secure electric strike.

It is recommended to install this kind of electric strike for all digital access control installations.

These top quality electric strikes, specially designed for security professionals, withstand pressures of up to 700 kg.

Technical featuresReinforced mechanism box

Stainless steel lock cover

Steel latch and screws

Electric strikes with electronic coils are released by applying a pressure up to 14kgWithstands impacts and pressures up to 500 Kg, getting destroyed at 700 Kg

300.000 guaranteed openings. Low power consumption

Corrosion resistant according to UNI ISO 9227 Standards

Complies with electromagnetic compatibility standard 2004/108/CE (EN55014)

Fail-secure

Internal Hold-open

The electric strike is locked when unenergized.

The electric strike has an internal device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door.

Fixed latch Preload

Voltageac/dcintermittent

12 V ac/dc

12 V ac/dc

24 V ac/dc

24 V ac/dc

4R0.4.00.X 4L0.4.00.X

4R2A.4.00.X 4L2A.4.00.X

4R2A.4.00.Z 4L2A.4.00.Z

4R0.4.00.Z 4L0.4.00.Z

ReferencesDIN leftadd faceplate

ReferencesDIN rightadd faceplate

52

9,2

11

106,4

29,5

20,5

3,5

45 107

Door Handedness

DIN definition:The door is viewed from the side on which the hinges are visible.

DIN Left DIN Right DIN Left DIN Right

SECURITY WITH ELECTRONIC COIL

Page 12: Lock Catalog

10

Reversible

Reversible Reversible

Reversible

159

253

52

44

65,5

49,5

Reversible Reversible

BROWN BROWN

16 17

172

48,5

2532

52

2 R10

R10

R 10R

10

44

Right RightLeft LeftDIN DIN

BROWN BROWN44 4547 48

225

32

250

48,5

44

12

70

61,7

5139,7

5

250

48,5

25

322

70

12

44

61,7

5139,7

5

52

R10

R10

R 10R 10

52

R10 R

10

R 10R 10

INOX 3mm

61

250

253

52

64

44

142

70

44

12

INOX 3mm

43

INOX 3mm

66

INOX 3mm

67

280

253

96

44

52

42

140

70

13

200

52

253

44

65,5

90,5

FACEPLATES

Page 13: Lock Catalog

11

References and featuresSymmetrical reversibility

Fail-secure

Fail-secure with 1 microswitch

Fail-secure with 2 microswitch

Internal Hold-open

Fail-safe

Fail-safe with 1 microswitch

Fail-safe with 2 microswitch

The electric strike is locked when unenergized.

It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.

It works just like the Fail-secure model plus 2 electrical switching device that detects the status of the electric strike and the door.

The electric strike has an internal device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.

The electric strike is locked when energized.

It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.

It works just like the Fail-safe model plus 2 electrical switching device that detects the status of the electric strike and the door.

Preload Electronic protection

Fixed latch Voltage References

add box

8-14 V ac/dc

8-14 V ac/dc

9-14 V ac/dc

12 V dc

12 V dc

12 V dc

12 V dc

24 V dc

24 V dc

12 V dc

12 V dc

24 V dc

24 V dc

24 V dc

24 V dc

40.6.00.L

46.6.00.L

46.6.00.M

44.6.00.M

46.6.00.N

44.6.00.N

47.6.00.P

47.6.00.N

40.6.00.M

40.6.00.N

48.6.00.M

48.6.00.N

49.6.00.P

49.6.00.N

42A.6.00.L

Coil features

Technical features

°C

Minutes 5(a 12 Vac)

(20 Ω 0,5 A a 12 Vac) 8/14 V ac/dcL

6266

°C

Hours 5

(70 Ω 0,17A) 12 Vdc 100%M

°C

Hours 5

(240 Ω 0,10A) 24 Vdc 100%N

57

°C

Hours 5

(54 Ω 0,22 A) 2 microswitch 12 Vdc 100%P

Warning:

When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.

Incorrect installation could cause door-release failure.

Temperature test:

Measured on coil surface, tolerance ±10%

Reinforced mechanism box

Stainless steel lock cover

Steel latch and screws

Electric strikes with 12V ac coils are released by applying a pressure up to 16 kgWithstands impacts and pressures up to 500 Kg, getting destroyed at 700kg.

300.000 guaranteed openings. Low power consumption

Corrosion resistant according to UNI ISO 9227 Standards

Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).Latch adjustment regulator (is supplied on demand)

62

5156

BLACK BLACK BLACK

RED RED RED

82 83 85

82 83 85

Operation

Fail-secure Fail-safe

opened openedclosed closed

Internal Hold-openFail-secure Fail-safe Fail-secure Fail-secureFail-safe Fail-safe

1 microswitch 2 microswitch

Schematic electric diagram

Push button Push button

Light

Secondary microswitch

S2

Principal microswitch S1

Power supply

Door opened

Unlocked lever (electric strike open)

Door closed

Light

Principal microswitchS1

Power supply

Door openedDoor closed

Interconnection between principal and secondary microswitch

Common

Connection

Door released and lever unlocked

Door closed and lever lockedDoor released

Electric connection

Unlocked lever connection

Locked lever connectionCommon

Electric connection

Door closed connection

Door released connectionPrincipal microswitch S1

Secondary microswitch S2

Common

Principal microswitch S1 Secondary microswitch S2

Intensity 1A/125 Vac0,5A/30 Vdc

0,5A/30 Vdc

Operating speed 1 at 500 mm/second (at pin plunger) 1 at 500 mm/second (at pin plunger)

Operating frecuency Mechanical: 200 operations per minute Electrical: 30 operations per minute

Mechanical: 200 operations per minute Electrical: 30 operations per minute

Contact resistance Standard type: 30 mΩ max. Standard type: 30 mΩ max.

Ambient temperature From -25°C a 65°C (without ice) From -25°C a 70°C (without ice)

Humidity 85% RH max. (5° a 35°C) 85% RH max. (5° a 35°C)

Life expectancy Mechanical: 300.000 operations min.Electrical: 30.000 operations min.

Mechanical: 30.000 operations min.Electrical: 30.000 operations min.

Other coils and voltages on demand

FAIL-SAFEFAIL-SAFE

FAIL-SECUREFAIL-SECURE

EMERGENCY FOR PUSH BAR LOCKS

Page 14: Lock Catalog

12

Deep surface box

Installation instructions:

Standard surface box

Installation instructions:

Shielded surface box

1- Unscrew the 2 screws that attach the electric strike mechanism to the box 82 and remove the electric strike.

2- Make the electrical connection of the electric strike.3- Place the electric strike back in the box 82 with the 2 screws holding it.4- Place the electric strike between 12-14 mm. from the panic device, the latch must be

aligned. Set the box 82 on the frame with 4 screws.5- Press the black nylon trim on top of the box 82 in order to hide the 4 holding points.

1- Unscrew the 2 screws that attach the electric strike mechanism to the box 83 and remove the electric strike.

2- Locate the C-83 accessories under the box 83 until the lach gets aligned. 3- Pass the electric cable through the holes of the C-83 accessories4- Place the C-83 accessories on the door at 12-14 mm. from the panic device.Hold

them with the screws.5- Make the electrical connection of the electric strike.6- Place the electric strike back in the box 83 with the 2 screws holding it.7- Set the box 83 on the C-83 accessories with 4 screws.8- Press the black nylon trim on top of the box 83 in order to hide the 4 holding points.

Set made up of one metalic base on which to install the electric strike and a sturdy protective box. This protective box is designed so that the points of union of the electricstrike and the door frame are not visible, ensuring the shield of the electric strike.

Installation instructions:

1- Place the electric strike on the metalic base.2- Place the C-83 accessories under the metalic base until the latch gets aligned.3- Pass the electric cable through the holes of the C-83 accessories and the metalic

base.4- Place the set on the door frame at 12-14 mm. from the panic device.Hold them with

2 screws.5- Make the electrical connection of the electric strike.6- Protect the set with the shielded box 85. Hold the box on the door frame with 4

screws.7- Press the black nylon trim on top of the shielded box 85 in order to hide the 4

holding points.

BLACK

BLACK

RED

RED

82

83

82

83

Latch and electric strike aligment

Part of the door frame will be cut to facilitate the turning of the elec-tric strike latch.

installation example

4

BLACK

RED

85

85

C83

48

43

160

2

160

27,35

160

160

27,35

44,65

67

1

2

3

5

SURFACE BOXES

Page 15: Lock Catalog

13

References and featuresReversible

Radial turning latch

Fail-secure

Fail-secure with mechanical unlatching

Fail-secure with microswitch

Fail-safe

Fail-safe with microswitch

The electric strike is locked when unenergized.

It works just like the Fail-secure model but with mechanical release function.

It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.

The electric strike remains in closed position, while the coil is selected. When the electric current is stopped, the electric strike stays in open position.

Like the Fail-safe model plus an electrical switching device that detects the status of the door.

Adjustable latch Preload Electronic

protection Voltage Referenceslatch (1)add faceplate

9-16 V ac/dc

9-16 V ac/dc

9-16 V ac/dc

12 V dc

12 V dc

6-12 V ac/dc

6-12 V ac/dc

12 V dc

24 V dc

24 V dc

12 V dc

12 V dc

24 V dc

24 V dc

24 V dc

50.1.00.B

51.1.00.B

56.1.00.B

50.1.00.J

51.1.00.J

56.1.00.E

50.1.00.E

51.1.00.E

56.1.00.F

50.1.00.F

51.1.00.F

54.1.00.E

58.1.00.E

54.1.00.F

58.1.00.F

Coil features

Dimensions

Technical features

7785

60

46

°C

Minutes 5

16 Vac

12 Vac

12 Vac

9 Vac9 Vac

6 Vac

(20 Ω 0,480 A a 12V ac) (8,5 Ω 0,820 A a 9V ac) (42 Ω 0,275 A) (192 Ω 0,120 A)9/16 V ac/dcB

58

39

°C

Minutes 5

6/12 V ac/dcJ

68

62

°C

Hours 5

12 Vdc 100%E

°C

Hours 5

24 Vdc 100%F

Electric strikes with «ac» coils work properly even with a pressure up to 16Kg.

300.000 guaranteed openingsReinforced anchor levers

Withstands impacts up to 400 Kg.

Steel screws

Low power consumption

Corrosion resistant according to UNI ISO 9227 Standards

Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).

Fail-secure Fail-securewith mechanical unlatching

with mechanical unlatching

Fail-secure with microswitch

Fail-safewith microswitch

Hold-open Hold-open Fail-safe

Warning:

When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.

Incorrect installation could cause door-release failure.

Temperature test:

Measured on coil surface, tolerance ±10%

Other coils and voltages on demand

5,9

9,8

9,8 1

3

46,6

16

5,9

9,89,8 13

46,6

Hold-open

Hold-open with mechanical unlatching

The electric strike has a device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door.

It works just like the Hold-open model but with mechanical release function.

9-16 V ac/dc

9-16 V ac/dc

6-12 V ac/dc

6-12 V ac/dc

52.1.00.B

52.1.00.J

53.1.00.B

53.1.00.J

new

65,5

16,5

72,55

28,1

MINI FOR ALUMINUM, WOOD & PVC DOORS

Page 16: Lock Catalog

14

6

65,3

48,3

130,2

44,5

33,2

227,5

44,5

48,3

18,8

32,5

66,5

24,3

33,2

12,1

2

R10

243,9

66,5

2,1

227,5

3

66,5

24,3

12,1

24

INOX 3mm

INOX 3mm

INOX 3mm

INOX 3mm

INOX 3mm22

24

26

25

23

DINRight Left

DINRight Left

Reversible

24

FACEPLATES

Page 17: Lock Catalog

15

References and features

Fail-secure

Fail-secure with 1 microswitch

Fail-safe

Fail-safe with 1 microswitch

Internal Hold-open

The electric strike is locked when unenergized.

It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.

The electric strike remains in closed position, while the coil is selected. When the electrical current is stopped, the strike stays in open position.

It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.

The electric strike has an internal device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door.

PreloadElectronic protection

Fixed latch Voltage

8-14 V ac/dc

8-14 V ac/dc

9-14 V ac/dc

12 V dc

12 V dc

12 V dc

24 V dc

24 V dc

12 V dc

24 V dc

24 V dc

7L0.4.00.L7R0.4.00.L

7L6.4.00.L7R6.4.00.L

7L6.4.00.M7R6.4.00.M

7L4.4.00.M7R4.4.00.M

7L6.4.00.N7R6.4.00.N

7L4.4.00.N7R4.4.00.N

7L0.4.00.M7R0.4.00.M

7L0.4.00.N7R0.4.00.N

7L8.4.00.M7R8.4.00.M

7L8.4.00.N7R8.4.00.N

7R2A.4.00.L 7L2A.4.00.L

ReferencesDIN leftadd faceplate

ReferencesDIN rightadd faceplate

Coil features

21,2

93,2

98,9

36

4,3

Fail-secure Fail-safe Internal Hold-open

Schematic electric diagram with microswitch

Dimensions

D D D D DI I I I I

Security coil support

®

100% waterproof box

®

Magnet + 100% waterproof REED

®

Power supply

Push button

Push button

light light

NC

NC

CO

M

CO

M

NO

NO

CO

IL

CO

IL

Technical featuresElectric strikes with «ac» coils work properly even with a pressure up to 15Kg.

Waterproof mechanism box

Withstands impacts and pressures up to 300 Kg, getting destroyed at 500kg.

300.000 guaranteed openings.

Reinforced mechanism box

Low power consumption.

Stainless steel screws.

Protected against water projected in all directions (IP54).

Corrosion resistant according to UNI ISO 9227 Standards

Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).

25

250

3

40,5

45,5

13

85

12

15

73,5

131

253

2504

0,5

13

15

85

131

45,5

73,5

INOX 3mm INOX 3mm INOX 3mm68 69 75Reversible Reversible Reversible

Door Handedness DIN definition:The door is viewed from the side on which the hinges are visible.

Warning:

When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.

Incorrect installation could cause door-release failure.

Temperature test:

Measured on coil surface, tolerance ±10%

Fail-secure Fail-safe1 microswitch

°C

Minutes 5(a 12 Vac)

(20 Ω 0,5 A a 12 Vac) 8/14 V ac/dcL

6266

°C

Hours 5

(70 Ω 0,17A) 12 Vdc 100%M

°C

Hours 5

(240 Ω 0,10A) 24 Vdc 100%N

62

5156

Other coils and voltages on demand

FAIL-SAFEFAIL-SAFE

FAIL-SECUREFAIL-SECURE

27

27

27

250

313

40,5

73,5

45,5

131

20

WATERPROOF FOR OUTDOOR APPLICATIONS

Page 18: Lock Catalog

16

References and features

Fail-secure

Internal Hold-open with mechanical unlatching

Fail-safe

The electric strike is locked when unenergized.

The electric strike has a an internal device that allows its opening with a single electrical impulse. It remains in open position until the closing of the door and has mechanical unlatching.

The electric strike is locked when energized.

Adjustablelatch Preload Electronic

protection Voltage

8-14 V ac/dc

9-14 V ac/dc

9-14 V ac/dc

24 V dc

12 V dc

12 V dc

24 V dc

9L0.1.00.L9R0.1.00.L

9R0.1.00.M

9R0.1.00.N

9R4.1.00.M

9R4.1.00.N

9R3A.1.00.L

9R2A.1.00.L

9L0.1.00.M

9L0.1.00.N

9L4.1.00.M

9L3A.1.00.L

9L2A.1.00.L

9L4.1.00.N

ReferencesDIN leftadd faceplate

ReferencesDIN rightadd faceplate

Coil features

Fail-secure Fail-safeInternal

Hold-open

D D DI I I

Operation Dimensions

77

36,3

32

23

83

88,5

Technical features

Faceplates

Designed for bolts-locked armoured doors.

4mm. distance between the latch and the first bolt of the electric strike.

Withstands impacts and pressures up to 400 Kg, getting destroyed at 700kg.

300.000 guaranteed openings. Reinforced mechanism box

Low power consumption. Steel screws.

Electric strikes with 12V ac coils are released by applying a pressure up to 16 kg

Corrosion resistant according to UNI ISO 9227 Standards

Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).

Latch adjustment regulator (is supplied on demand)

Stainless steel lock cover

Door Handedness

35 3

247

O 20

68,5

37

141,5

INOX 3mm 70

35 3

247

O 20

68,5

37

141,5

INOX 3mm 60Reversible Reversible

opened closed

°C

Minutes 5(a 12 Vac)

(20 Ω 0,5 A a 12 Vac) 8/14 V ac/dcL

6266

°C

Hours 5

(70 Ω 0,17A) 12 Vdc 100%M

°C

Hours 5

(240 Ω 0,10A) 24 Vdc 100%N

62

5156

Warning:

When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.

Incorrect installation could cause door-release failure.

Temperature test:

Measured on coil surface, tolerance ±10%

internal hold-open

Adjustable latch (3mm)

34,8 9,3

10,814,2

34,8 6

10,814,2

Standard adjustable latch Ref. 1

Deep adjustable latch Ref. 3

Other coils and voltages on demand

DIN definition:The door is viewed from the side on which the hinges are visible.

FAIL-SAFEFAIL-SAFE

FAIL-SECUREFAIL-SECURE

ARMOURED FOR MULTIBOLT LOCKS

Page 19: Lock Catalog

17

52

9,2

11

106,4

29,5

20,5

3,5

45107

References and features

Fail-secure

Fail-secure with 1 microswitch

Fail-safe

Fail-safe with 1 microswitch

The electric strike is locked when unenergized.

It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.

The electric strike is locked when energized.

It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.

PreloadElectronic protection

Fixed latch Voltage

8-14 V ac/dc

8-14 V ac/dc

12 V dc

12 V dc

12 V dc

24 V dc

24 V dc

12 V dc

24 V dc

24 V dc

24L0.4.00.L24R0.4.00.L

24L6.4.00.L24R6.4.00.L

24L6.4.00.M24R6.4.00.M

24L4.4.00.M24R4.4.00.P

24L6.4.00.N24R6.4.00.N

24L4.4.00.N24R4.4.00.N

24L0.4.00.M24R0.4.00.M

24L0.4.00.N24R0.4.00.N

24L8.4.00.M24R8.4.00.P

24L8.4.00.N24R8.4.00.N

ReferencesDIN leftadd faceplate

ReferencesDIN rightadd faceplate

Faceplates

Door Handedness

Dimensions

Schematic electric diagram with microswitch

Fail-secure Fail-safe

D D D DI I I I

Push button

Door openedDoor closed

Power supply

Principal microswitch S1

light

NO

COM

NC

Technical featuresHeat resistance: 1150 ° C for 2 HoursApproval standard UNE EN 1634 - 1, RF 120

Stainless steel lock cover

Withstands impacts and pressures up to 1000 Kg

300.000 guaranteed openings

Reinforced mechanism box

Stainless steel screws

Low power consumption

Electric strikes with 12V ac coils are released by applying a pressure up to 16 kg

Corrosion resistant according to UNI ISO 9227 Standards

Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).

159

253

52

44

65,5

49,5

ReversibleINOX3mm61

INOX3mm66

200

52

253

44

65,5

90,5

Coil features

°C

Minutes 5(a 12 Vac)

(20 Ω 0,5 A a 12 Vac) 8/14 V ac/dcL

6266

°C

Hours 5

(70 Ω 0,17A) 12 Vdc 100%M

°C

Hours 5

(240 Ω 0,10A) 24 Vdc 100%N

62

5156

Warning:

When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.

Incorrect installation could cause door-release failure.

Temperature test:

Measured on coil surface, tolerance ±10%

Operation

opened closed

Fail-secure Fail-safe

1 microswitchFail-secure Fail-safe

openedclosed

Other coils and voltages on demand

DIN definition:The door is viewed from the side on which the hinges are visible.

FAIL-SAFEFAIL-SAFE

FAIL-SECUREFAIL-SECURE

FIRE FOR RF-120 DOORS

Reversible

250

253

52

64

44

142

70

44

12

INOX 3mm

43

Page 20: Lock Catalog

18

References and featuresReversible

Radial turning latch

Fail-secure

Fail-secure with 1 microswitch

Hold-open

Fail-safe

Fail-safe with 1 microswitch

The electric strike is locked when unenergized.

It works just like the Fail-secure model plus an electrical switching device that detects the status of the door.

The electric strike has a device that allows its opening with a single electric impulse. It remains in open position until the closing of the door.

The electric strike is locked when energized.

It works just like the Fail-safe model plus an electrical switching device that detects the status of the door.

Adjustablelatch Preload Electronic

protection Voltage Referenceslatch (1)add faceplate

8-14 V ac/dc

8-14 V ac/dc

5-12 V ac/dc

8-14 V ac/dc

12 V dc

12 V dc

5-12 V ac/dc

12 V dc

5-12 V ac/dc

24 V dc

24 V dc

12 V dc

24 V dc

24 V dc

250.1.00.B

256.1.00.B

256.1.00.J

250.1.00.J

256.1.00.E

250.1.00.E

256.1.00.F

250.1.00.F

252.1.00.B

252.1.00.J

254.1.00.E

258.1.00.E

254.1.00.F

258.1.00.F

Dimensions

Fail-secure Fail-secure with microswith

Fail-safewith microswith

Hold-openFail-safe

11,6

5

6

2

11,6

5

11,6

5

15,3

43,8

11,6

5

15,3

43,8

Technical featuresElectric strikes with «ac» coils work properly even with a pressure up to 16Kg.

300.000 guaranteed openingsSteel levers

Withstands impacts and pressures up to 1000 Kg

Steel screws

Low power consumption

Corrosion resistant according to UNI ISO 9227 Standards

Complies with electromagnetic compatibility standard 2004/108/CE (EN55014).

Coil features

105

°C

Minutes 5(a 12 Vac)

(14 Ω 0,7 A a 12 Vac) 8/14 V ac/dcB

65

°C

Minutes 5(a 9 Vac)

(8 Ω 0,6 A a 9 Vac) 5/12 V ac/dcJ

Warning:

When installing door releases with DC con-nections, the electric strike latch should not exert any pressure on the door-release latch.

Incorrect installation could cause door-release failure.

Temperature test:

Measured on coil surface, tolerance ±10%

new

70

28

78,5

20,5

20,5

0,5

28,5

53

°C

Hours 5

(50 Ω 0,25 A) 12 Vdc 100%E

77

°C

Hours 5

(185 Ω 0,12 A) 24 Vdc 100%F

Other coils and voltages on demand

HIGH-SECURITY FOR ACCESS CONTROL SYSTEMS& HEAVY DUTY DOORS

Page 21: Lock Catalog

19

new

Reversible

159

253

52

44

65,5

49,5

INOX 3mm61Reversible

INOX 3mm66

200

52

253

44

65,5

90,5

25

30,7

548,5

30,7

5

44

110

3

52

INOX 3mm62

Reversible

Reversible

63 D63 C63

25

61,7

548,5

139,7

5

12

79

35

44

250

3

52

INOX 3mm 65 D65 C65

Reversible

25

61,7

548,5

139,7

5

102

12,544

250

12

3

52

64 D64 C64

25

61,7

548,5

139,7

5 17

44

12,5

102

250

3

52

Right LeftDIN

INOX 3mm73 74

52

34

64

48

128

14

90

124

4

240

2

BROWN17

Reversible

R10

R 10R 10

R10

52

Reversible

BROWN16

48,5

25

32

44

172

R10

R10

R 10 R 10

52

12

R10 R

10

R 10R 10

52

12

Right LeftDIN

BROWN12 13

12

102

44

250

32 25

2

250

44

12

102

48,5

2

32

25

Right LeftDIN

BROWN08 09

FACEPLATES

Page 22: Lock Catalog

20

MICRO for cabins, lockers & drawers

DOOR HOLDERS for fire doors

MINI for access control & emergency exits

UNIVERSAL for access control & emergency exits

WATERPROOF for outdoor applications

SHEARLOCKS for swing and sliding doors

new

new

MAGLOCKS

Page 23: Lock Catalog

21

MICRO for cabins, lockers & drawers

DOOR HOLDERS for fire doors

MINI for access control & emergency exits

UNIVERSAL for access control & emergency exits

WATERPROOF for outdoor applications

SHEARLOCKS for swing and sliding doors

new

new

MAGLOCKS32,5

39,5

24

90

Dimensions

Electrical connection

Holding force: 700 N

MEX70

MBAX70

Power supply 12Vdc - 340mA

Power supply 24Vdc - 165mA

ZBracket

38

75

38

38

4,5

For doors that open inwards

UBracket

41

70

16

28

MHAX70

For glass doors

new

69,2

32,9

7

MICRO FOR CABINS, LOCKERS & DRAWERS

Page 24: Lock Catalog

22

References

DHI Industrial door holder

DHS Basic door holder

DHB Dual tension door holder

DHT Timed door holder

DHD Door holder with power-regulation

DFS Door holder support

Dimensions Technical features

Diameter: 50mm.Holding force: 600 NPower supply: 24 VdcElectric connexion: 2 wires

side or rear exit24Vdc consumption: 0,085 APower: 2 W

Diameter: 50mm.Holding force: 600 NPower supply: 12/24 Vdc12Vdc consumption: 0,170 A24Vdc consumption: 0,085 AVoltage change: with jumperPower: 2 WPush button to unlock the door

Diameter: 50mm.Holding force: 600 NPower supply: 24 VdcTimer: 3 seg.24Vdc consumption: 0,085 APower: 2 WPush button to unlock the door

Diameter: 50mm.Max. Holding force: 600 NMin. Holding force: 300 NPower supply: 24 Vdc600N consumption: 0,085 APower: 2 WPush button to unlock the door

new

24,7

O50

7O55

28

60

60

O50

15

60

60

O55

65

65

55

51

46,2

83

90

,42 5

O50

39

8080

83

39

90

83

192

65

65

65

65

5555

51

51

46,2

46,2

83

83

90

90

,42 5

,42 5

O50

O50

All models are equippedwith ejector pins to overcome residual magnetism

DOOR HOLDERS FOR FIRE DOORS

Page 25: Lock Catalog

23

References and featuresElectronic protection

Holding force

Installation Mortise Rim

References

ME-200/210

ME-201/211

ME-400/410/420

ME-600/610/620

Packaging dimensions Total weight

1,8 Kg

1,8 Kg

1,8 Kg

4 Kg

500 mA

500 mA

500 mA

500 mA

250 mA

250 mA

250 mA

250 mA

6 W

6 W

6 W

6 W

Electric consumption12 Vdc 24 Vdc Power

Fitting system round squared Led Reed Voltage

12/24 VdcReferences

2800 N

2800 N

2800 N

2800 N

2800 N

2800 N x 2

2800 N

2800 N

2800 N x 2

2800 N x 2

ME-200

ME-201

ME-210

ME-211

ME-400

ME-410

ME-420

ME-600

ME-610

ME-620

40

305105

40

305105

40

305105

40

550105

249

202 26

26202239

26535

40

202

525

30

30

35

31

MINI FOR ACCESS CONTROL & EMERGENCY EXITS

Page 26: Lock Catalog

24

50185

35

12

265

References and features

Wiring and voltage switching

Brackets for mini electromagnetic locks

for outwardopening doors

Brackets L Z UBrackets Brackets

for inwardopening doors

for glass doors

Brackets for double mini electromagnetic locks Base for RF door Finish selection chart

Installation and features of the electric strike faceplate

50

50265

50

50525

5050

50270

26

39

190MBE-806

MBE-807 MRF-810 FSC-821

MBA-801 MHA-804

MBA-802

REED SWITCH FEATURES REED SWITCH CONTACTS REED SWITCH CONTACTS

VOLTAGE CHANGE

JUM

PER

JUM

PERS

JUMP CONNECTOR SET VOLTAGE

MAXIMUM SWITCHING VOLTAGE 100 VDC (VOLTS DC)MAXIMUM SWITCHING CURRENT 0.3 A (AMPS DC)MAXIMUM CONTACT RATING 3 W (WATTS DC)

JUMP CONNECTOR SET VOLTAGE JUMP CONNECTOR SET VOLTAGE DC POWER INPUT DC POWER INPUT

LED

DC POWER INPUTCorrect position of voltage selection jumpers

Voltage selection pins

Door properly lockedDoor improperly locked(electric strike plate incorrectly positioned)Electromagnetic lock out of order(failure on the electric power supply)

L B H L1 D1 D2HOLDING FORCE

MEASURES

2800 N 185 35 12 165 17 9

D2

D1

H

Ø 5,5Ø 5,5

3

L1

L

B

Warning: Do not fasten the center screw too tightly. The plate must be loose.

HEX BOLT

Hex bolt

Joint

Washers

Armature

Screw

Hex bolt2 JointsScrew

Stringer2 Washers

Door

Stringer

Armature fastening holes

HEX BOLT

WASHER

ARMATURE

SCREW

JOINT JOINT JOINT

SCREW SCREW

ARMATURE ARMATURE

WASHER WASHER

DOORDOORDOOR

The armature must be fastened exactly as shown above.

Fixing the armature to a steel, PVC or aluminium profile.

The parts shown above are delivered with each magnet.

Fixing the armature on a wooden door.Fixing the armature on armoured steel doors.The steel needs to be thick enough to fastenthe screw on the steel door.

If the steel is not thick enough, the plate mustbe fastened with the hex bolt.

BRACKETS FOR MINI MAGLOCKS

Page 27: Lock Catalog

25

References and featuresElectronic protection

Timer from2 to 8 sec.

Holding force

Electric consumption12 Vdc 24 Vdc

Installation Mortise Rim

Security device

Dual voltage 12/24 Vdc changing automatically

Voltage12 Vdc ReferencesLed Reed

1800 N

3000 N

6500 N

3000 N

3000 N x 2

6500 N

3000 N

3000 N x 2

6500 N

MEX-100

MEX-201

MEX-400

MEX-430

MEX-600

MEX-630

MEX-700

MEX-730

MEX-900

Dimensions Packaging dimensions Total weight

1,2 Kg 250 mA 3 W

2,15 Kg 270 mA 3,3 W

2,25 Kg 270 mA 180 mA 3,3 W

2,25 Kg 270 mA 180 mA 3,3 W

4,4 Kg 270 mA 180 mA 3,3 W

4,4 Kg 270 mA 180 mA 3,3 W

4,1 Kg 270 mA 180 mA 3,3 W

4,1 Kg 270 mA 180 mA 3,3 W

4,5 Kg 270 mA 180 mA 3,3 W

Power

MEX-100

37

295120

37

295120

37

295120

37

295120

37

520120

37

520120

50

308160

50

308160

50

308160

MEX-201

MEX-400

MEX-430

MEX-600

MEX-630

MEX-700

MEX-730

MEX-900

22

23

28

28

28

28

40

46

52

52

52

52

166

248

241

241

482

482

265

265

265

315

70

70

65

35

35

40

228

UNIVERSAL FOR ACCESS CONTROL & EMERGENCY EXITS

Page 28: Lock Catalog

26

Brackets for 180 Kg electromagnetic locks

Brackets for 300 Kg electromagnetic locks

Brackets for 600 Kg electromagnetic locks

Installation and features of the electric strike faceplate

References and features

MBEX-180 MBAX-180(3 units)

MHAX-180

MHAX-300MBAX-300(3 units)

MBAX-600(3 units)

MBEX-300

MBEX-600

for outwardopening doors

Brackets L ZBrackets

for inwardopening doors

UBrackets

for glass doors

40

35166

45

35240

75

40265 75

43

70

40

65

180

265

HOLDING FORCE

MEASURES

1800 N 135,5

L B H L1 D1 D2

31,5 8,6 120 Ø10 Ø5,6

Ø16 Ø 9

Ø16 Ø 9

160 45,3 12,6 140

175 62 13,6 150

3000 N

6000 N

20

20

40

40

135

160

D2

D1

H

Ø 5,5Ø 5,5

3

L1

L

B

Warning: Do not fasten the center screw too tightly. The plate must be loose.

HEX BOLT

Hex bolt

Joint

Washers

Armature

Screw

Hex bolt2 JointsScrew

Stringer2 Washers

Door

Stringer

Armature fastening holes

HEX BOLT

WASHER

ARMATURE

SCREW

JOINT JOINT JOINT

SCREW SCREW

ARMATURE ARMATURE

WASHER WASHER

DOORDOORDOOR

The armature must be fastened exactly as shown above.

Fixing the armature to a steel, PVC or aluminium profile.

The parts shown above are delivered with each magnet.

Fixing the armature on a wooden door.Fixing the armature on armoured steel doors.The steel needs to be thick enough to fastenthe screw on the steel door.

If the steel is not thick enough, the plate mustbe fastened with the hex bolt.

26

40166

33

52240

45 45

40135

50 50

50160

BRACKETS FOR UNIVERSAL MAGLOCKS

Page 29: Lock Catalog

27

Electronic protection

Holding force IP65

Installation: Rim

References

ME-500

ME-510

Packaging dimensions

Product especially designed for outdoor installations. IP65 approval and total protection against weathering.

Total weight

1,9 kg

1,9 kg

1100 mm.

1100 mm.

500 mA

500 mA

250 mA

250 mA

6 W

6 W

PowerCable length

Electric consumption 12 Vdc 24Vdc

Chrome finish

Fitting system squared Reed Voltage

12/24 VdcReferences

2500 N

2500 N

ME-500

ME-510

References and features

305

305

40

40

105

105

D2

D1

H

Ø 5,5Ø 5,5

3

L1

L

B

Dimensions

Connections

Brackets for mini electromagnetic locks

ME-500ME-500

ME-510ME-510

MBE-806

MBE-808

MBE-801

MBE-802

24 V dcwithout polarity

12 V dcwithout polarity

24 V dcwithout polarity

12 V dcwithout polarity

contactsrelay «REED»

contactsrelay «REED»

5050

50270

50

34

50

34

265

265

NO NO

C C

NC NC

grey grey

4 drills D=5,2 for plain faced screws(DIN 965 or similar)

white white

red redgreen greenyellow yellow

blue blue

black black

brown brown

red redblue blueyellow yellow

4 or 7 wires depending on the model

L B H L1 D1 D2HOLDING FORCE

MEASURES

2500 N 185 35 12 165 17 9

WATERPROOF FOR OUTDOOR APPLICATIONS

Page 30: Lock Catalog

28

What is a shearlock and how it works

Example of use

Dimensions

Rim

Mortise

Glass door

A shearlock is an electromagnetic lock that combines magnetic and mechanical force, generating a holding power of up to 15.000N.

It can be installed on all kinds of left and right handed doors (metal, wooden and glass), either horizontally or vertically. It is the ideal lock for swing doors and emergency doors equipped with panic devices.

A magnetic sensor detects when the door and doorframe are aligned and makes the shearlock lock the door in place. When a sherlock is deactivated via an access control system or a button, the door is released. If, however, the door is no physically open within the T1 progra-mmed time (closing delay), the shearlock will automatically lock the door again. Otherwise, the door can be kept unlocked for a specific time simply by interrupting the power supply.

Shearlocks operate on 10-36V dc, so the installer does not have to set the voltage. They have two power connections and an adjustable delay system, which means a delay between 1 and 25 seconds for realease and locking can be set.

Shearlocks are designed to be connected for instant-release buttons, traffic lights, access control systems, radio alarms and even heat and smoke detectors, in order to release the door immediately in case of fire.

There is an attempted robbery in a department store and the thief tries to escape through an emergency door with a panic device and a shearlock.

When the thief pushes the panic bar, the door will still be locked by the shearlock for the programmed time, and a warning signal can be sent to the store’s emergency control center. If the system is equipped with an acoustic alarm, it will be ringing for the time the shearlock is programmed to. When the thief discovers the door is locked, he will be forced to drop the goods.

Once the door is released, the store’s security personnel will have to reset the shearlock to stop the alarm and reset the system.

Different installation possibilities

A) Rim

Door only opens one way

Swing door

B) Mortise

Door only opens one way

Swing door

Shearlock for glass doorModel: SH300

A) Shearlock surface mountedB) Shearlock glass doorModel: SH400

A) Shearlock built-inB) Shearlock glass doorModel: SH500

C) Glass and swing doors

Mixed installation Mixed installation

Model: SH100Silver

Model: SH200Grey

A

B

A

B

SHEARLOCKS FOR SWING & SLIDING DOORS

Page 31: Lock Catalog

29

Electrical features:

Power supply:10-36 V dc, there is no need to set the voltageConsumption for 12 V dc 2A startup and 0,5 A operating current.

Coil:Tropicalized.

Autoprotection:If the closing manoeuvre is not executed correctly because there is a defect in alignment or there is an object preventing closure, the system tries to close seve-ral times. If after five attempts the shearlock cannot be closed, it remains in the open position and triggers an alarm. This prevents the product from overheating, which causes the deterioration of the product.

Auxiliary relay: Inversion circuit. Maximum current: 1 A at 24 V dc.When activated, the door is locked.When deactivated, the door is released.

Time delays:When locking/ aligning: 4 sec. ( adjustable from 0 to 25 sec )When releasing/ in an emergency: 15 sec ( adjustable from 0 to 25 sec )The adjustments can be independent from each other. Values shown are factory default settings.

Additional features:Locking prevention: this connection keeps the door released, even though the power is connected.Opening delay: either through an instantaneous connection or a button with timed opening.

Alarms:Intermittent alarm:

The electromagnet and door plate are not aligned.Attempted forced entry.Coil malfunction.Position sensors not aligned.Alarm indications are cancelled after 15 sec. or disconnecting the power supply.

Continuous alarm:Indicates the countdown to door release.Deactivates through the locking-prevention system or by disconnecting the power supply.

3 color LED indicator:Green: door released.Red: door closed.Amber: malfunction or transitory state.

Warning:Maximun space between parts = 3 mm

Magnetic alignment sensors

Power supply connectionLEDT2 Release-delay adjustmentFOR PANIC DEVICES

T1 Locking-delay adjustment

External alarm circuit:4 + Common with the shearlock8 - Auxiliary through the transistor in the shearlock circuitMaximum current: 350mA

Pulsador apertura instantánea y reset4 + Common with the shearlock3 Active

Power supply (10 to 36 VDC)

Emergency release delay

Auxiliary ( - )Alarm ( - )

Relay

1 A at 24 V

Immediate release and reset auxiliary ( + )

Transistor within the shearlock’s own electronic circuit

Model SH-200Model SH-100

Page 32: Lock Catalog

30

Model: SH-300

Installation instructions

Installation example

Warning: Maximum space between parts = 3 mm

1) Ensure the separation between the two glass plates (fixed part and moving part) is 6,5 mm or more. 2) Install the two parts of the shearlock so they are perfectly aligned and parallel.3) For the sensor to detect when the door is closed, the separation between the two parts of the shearlock should not exceed 3 mm.

LOCKINGM6 allen key (2 units)3 mm spanner

INSTRUCTIONS

1. Remove the protective backing.2. Put the bracket in place.3. Remove the two locking screws. 4. Use the set screw to push the bearing strip forward until it exerts pressure on the glass.5. Insert and tighten the locking screws until they lock into the set screws.

Adhesive strip withprotective backing

BERING STRIPFOR THE GLASS

SET SCREW FOR BERING STRIPFOR THE GLASS (2 units)M6 allen key3 mm spanner

Power supply

Hydraulicspring

Traffic light

Coded access controlAC-100

Power supply from 10 to 36 VdcMaximum current: 2,5 A at 10 VOperating current: 0,5 A at 10 VStabilized direct currentObserve connection polarity

Traffic light

SHEARLOCKS FOR GLASS DOORS

Page 33: Lock Catalog

TRAFFIC LIGHTS for access control systems

DOOR LOOPS for any kind of installations

DOOR CONTACTS for any kind of installations

PROVISIONAL LATCH for construction works

POWER SUPPLIES for any kind of installations

RIMTOPLOCK for door entry and access control systems

new

new

new

new

ACCESSORIES

31

Page 34: Lock Catalog

32

110

40

80

2618,6

129,

5 80

4040

4,5

11

1422

Jumper operation

Traffic lights dimensions Box dimensions

10-24 V ac/dc(flashing or steady light mode)

10-24 V ac/dc(flashing or steady light mode plus audible warning device)

Electrical connection

TLX001 TLP002 TLB001 TLB002

2 LEDS(Red and green)

2 LEDS(Red and green) + push button

2 LEDS(Red and green) + audible warning device

2 LEDS(Red and green) + push button + audible warning device

The audible warning device and the LED light remains in flashing mode.

the audible warning device and the LED light remains in steady mode.

Non polarized power supply 10-24 Vac / dc COM

Green LED contact

Red LED contact

without jumper with Jumper

new

TRAFFIC LIGHTS FOR ACCESS CONTROL SYSTEMS

Page 35: Lock Catalog

33

39

47

22

39

47

22

Model

EFX150 14,5 mm

14,5 mm

14,5 mm

14,5 mm

14,5 mm

14,5 mm

14,5 mm

14,5 mm

Steel 150 mm

150 mm

320 mm

500 mm

200 mm

200 mm

400 mm

400 mm

250 mm

250 mm

420 mm

600 mm

300 mm

300 mm

500 mm

500 mm

SFX250 Steel

SFX420 Steel

SFX600 Steel

BFX500G

BFX500B

DDC002

BFX300G

BFX300B

Grey boxSteel Flex tube

Brass boxSteel Flex tube

Grey boxSteel Flex tube

Brass boxSteel Flex tube

Diameter Finish color Flex tube lenght Total lenght

References and features

Dual electrical contacts

Electrical features

Maximum voltage: 24 V ac/dcMaximum intensity: 1,5 A. ac/dc

6

11

13

70

58

11

6

new

References and features

DOOR LOOPS FOR ANY KIND OF INSTALLATIONS

DOOR CONTACTSFOR ANY KIND OF INSTALLATIONS

Page 36: Lock Catalog

34

For faceplates located on building sites

The CSR001 provisional latch can be installed in all OPENERS & CLOSERS faceplates

Provisional latch CSR001 (3mm adjustable)

faceplate 03 faceplate 03 + CSR001

During construction work, it is possible to install a provisional latch CSR 001 that will leave the faceplate ready for the installation at the corresponding electric strike.

The latch replacement CSR 001 allows to keep the doors closed during the construction process, and is supplied with the 3 mm adjustable latch.

52,3

44,75,4

12,6

12,6

Dimensions

new

PROVISIONAL LATCH FOR CONTRUCTION WORKS

Page 37: Lock Catalog

35

References and featuresPower supplies at DC current

Power supply at AC current

Input Output Output Stability Protection Degree Power Battery Battery Capacity References Voltage Voltage Current Charge

230 V 50/60Hz 12 V dc 6 A dc 3% IP20 80 W yes PS 901*

230 V 50/60Hz 24 V dc 3 A dc 3% IP20 80 W yes PS 902*

230 V 50/60Hz 12 V dc 6 A dc 3% IP20 80 W yes 12 V dc 7 Ah PS 905**

230 V 50/60Hz 24 V dc 3 A dc 3% IP20 80 W yes 24 V dc 4 Ah PS 906**

230 V 50/60Hz 12 V dc 3 A dc 3% IP20 30 W PS 907*

230 V 50/60Hz 24 V dc 1,5 A dc 3% IP20 30 W PS 908*

High efficiency (77-87%) switching power supplies.Temperature operation between 0° - 40°CSingle output, over voltage, over heating and short circuit protection.Double function: power supply and batteries charging “on line” system, with complete discharge protection

* Finish DIN rail 35 x 7.5 ( DIN 500 22 )** 4 terminals for 2 electromagnetic locks each, with switches and operation warning light controls.

230 V 50/60Hz 12 V ac 1,5 A ac IP20 18 VA PS 903*

PS 901

PS 902

PS 907 PS 905

PS 908

PS 906

PS 903

POWER SUPPLIES FOR ANY KIND OF INSTALLATIONS

Page 38: Lock Catalog

36

When the door is aligned with the frame, the magnetic detector located at the (front) lock box, blocks the door.

Once the lock is released, and during the scheduled opening time, the lock makes an intermittent warning sound. After a scheduled time, the lock blocks automatically.

An acoustic alarm warns when the door is not properly closed.

General operation:

CE-104

CE-105

CE-106

CE-109

VCX-100 Rain-protection steel visor

Dimensions and electric diagram

Warning: The distance between the electric strike and the front box should be 5 mm. Distance plastic controller included.

Features and functional description• Mechanical opening handle

• Push button for electrical opening

• External cylinder for key opening

• Reversible, 60 mm cylinder

• 12 V dc power supply

• 500mA energy consumption

• 350.000 guaranteed openings

ENTRY: 1) Access control opening 2) Key opening

EXIT: 1) Electrical opening using the red push button 2) Electrical opening using access control 3) Mechanical opening using lock handle

IN CASE OF ELECTRICAL POWER CUT OFF: 1) Entry with keys 2) Exit using lock handle

Features and functional description• Mechanical opening handle

• External cylinder for key opening

• Reversible, 60 mm cylinder

• 12 V dc power supply

• 500mA energy consumption

• 350.000 guaranteed openings

ENTRY: 1) Access control opening 2) Key opening

EXIT: 1) Electrical opening using access control or pressing the button 2) Mechanical opening using lock handle

IN CASE OF ELECTRICAL POWER CUT OFF: 1) Entry with keys 2) Exit using lock handle

Features and functional description• Internal and external cylinder for key opening

• Reversible, 60 mm cylinder

• 12 V dc power supply

• 500mA energy consumption

• 350.000 guaranteed openings

ENTRY: 1) Access control opening 2) Key opening

EXIT: 1) Electrical opening using access control or pressing the button 2) Mechanical opening using keys

IN CASE OF ELECTRICAL POWER CUT OFF: 1) Entry with keys 2) Exit with keys

Features and functional description

• Mechanical opening handle

• Push button to lock / unlock permanently

• External cylinder for key opening

• Reversible, 60 mm cylinder

• 12 V dc power supply

• 500mA energy consumption

• 350.000 guaranteed openings

ENTRY: 1) Access control opening 2) Key opening

EXIT: 1) Electrical opening using access control or pressing the button 2) Mechanical opening using lock handle

IN CASE OF ELECTRICAL POWER CUT OFF: 1) Entry with keys 2) Exit using lock handle

The lock remains in permanent unblock position pressing the green button. The lock becomes operative again with a second press, which cancels the permanent unblock.

Blue (-)Red (+)12V dc

9442

58

80

40

96100

129,5

126

4155

a

a

Lock Motor

Green

RedRed

Door sensor

Pushbutton

Exteriorpushbutton

Lock switchpush button

Door sensor

Green

Lock Motor

RIMTOPLOCK FOR DOOR ENTRY& ACCESS CONTROL SYSTEMS