4
LOCATOR System LOCATOR System HIOSSEN Inc. www.hiossen.com 85 Ben Fairless Dr, Fairless Hills, PA 19030, USA TEL : 1-888-678-0001 FAX : 1-267-759-7004 HIOSSEN LOCATOR SYSTEM

LOCATOR - MaxFacWhen tightening abutment by hand When removing replacement male from denture cap Fixture Lab Analog Fixture Lab Analog Transfer Transfer HS System HS LOCATOR Abutment

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LOCATOR - MaxFacWhen tightening abutment by hand When removing replacement male from denture cap Fixture Lab Analog Fixture Lab Analog Transfer Transfer HS System HS LOCATOR Abutment

LOCATOR� SystemLOCATOR� System

HIOSSEN Inc. www.hiossen.com85 Ben Fairless Dr, Fairless Hills, PA 19030, USA TEL : 1-888-678-0001 FAX : 1-267-759-7004

HIOSSEN LOCATOR� SYSTEM

Page 2: LOCATOR - MaxFacWhen tightening abutment by hand When removing replacement male from denture cap Fixture Lab Analog Fixture Lab Analog Transfer Transfer HS System HS LOCATOR Abutment

03HIOSSEN

LOCATOR� SYSTEM LOCATOR� SYSTEM

HIOSSEN LOCATOR� SYSTEM

■ Features- Stable dual retention & optimal holding capabilities

against various retention forces (6N, 12N, 22N)

- Excellent durability

- Possible denture restorations even at small vertical

dimension

- Accommodate up to 40。divergence between two

implants

- Retention males can be easily placed & removed

with core tool

■ Indications- Implant retained overdenture in the mandible or

maxilla.

■ Contraindications- Tooth and implant supported overdenture

- Divergences greater than 40。between two

implants.

HIOSSEN LOCATOR� SYSTEM

Replacement Male

Denture Cap

Black ProcessingMale

Lab Analog

Core Tool

0。~10。divergence 10。~20。divergence

Description Component Flow Diagram Tool

Impression Coping

Abutment

Fixture

Block out spacer

HS System HG SystemTorque Driver

Page 3: LOCATOR - MaxFacWhen tightening abutment by hand When removing replacement male from denture cap Fixture Lab Analog Fixture Lab Analog Transfer Transfer HS System HS LOCATOR Abutment

05HIOSSEN04 HIOSSEN LOCATOR� SYSTEM

Procedure of LOCATOR� SYSTEM

■ Fabricating individual tray

Note

Connect healing abutments

�During wax rim fabrication, use denture cap with blackprocessing male for retention on bite registration.

�Selecting the replacement malesIn the case of implant divergences of more than10。to 20。, using extended range replacement males (red or green) can give much retention and durability.

When selecting males, it is recommended to use theBlue male (least retention) first. If the patients feelsthat they are too loose, then use the ones with greaterretention force.

Blue � Pink � Clear

Take impression Fabricate Individual tray Fabricate metal frameon the denture caps

Denture curing Remove black processing maleusing core tool

① ②

■ Curing denture & changing replacement males (Basic procedure)

■ Taking impression & Fabricating working model

Tighten Abutments (30Ncm) Connected LOCATOR� abutments Connect impression copings

④③ ⑤

⑫⑪ ⑬

insert replacement male usingcore tool

Locator overdenture Setting

⑮⑭ �

Obtained denture cap positionsafter the curing

Resin spill way on thelingual surface

■ Curing denture & changing replacement males (Intra-oral Technique)

⑫⑪ ⑬

Insert block out spacer Connect black processing maleinserted denture caps

Apply self-curing resin

⑮⑭ �

Try-on & curing Remove excessive resin Remove black processing maleusing core tool

�� �

insert replacement male usingcore tool

Locator overdenture Setting

�� �

Connected lab analogs Fabricate working model Place black processing maleinserted denture caps

⑨⑧ ⑩

Take impression

Upper abutment margin should beover 1.0mm from the mucosa level

Connect lab analogs

⑥ ⑦

1mm

Fabricate metal frame after blockingout the denture cap area

LOCATOR� SYSTEM LOCATOR� SYSTEM

Page 4: LOCATOR - MaxFacWhen tightening abutment by hand When removing replacement male from denture cap Fixture Lab Analog Fixture Lab Analog Transfer Transfer HS System HS LOCATOR Abutment

07HIOSSEN06 HIOSSEN LOCATOR� SYSTEM

HIOSSEN LOCATOR� SYSTEM

■ Fixture level Impression

When using Hiossen fixture level impression components, It is also possible to take impression at the level of fixture withoutLOCATOR� abutment.

■Using The LOCATOR� Core Tool

Pick-up

Pick-up

Fixture Impression Coping

Fixture Impression Coping

▶When inserting replacement males into denture cap

▶When tightening abutment by hand

▶When removing replacement male from denture cap

Fixture Lab Analog

Fixture Lab Analog

Transfer

Transfer

HS System

HS LOCATOR� Abutment

Component & Tool

LOCATOR�

Impression Coping (4Pack)

LOCATOR� Core Tool

LOCATOR� Male Processing Kit (2Pack)

LICS

LMPS

HG LOCATOR� Abutment

HG System

① ②

③ ④

⑤ ⑥

Gap

① Unscrew the tip until the gap betweenthe tip & the body is visible

② Press on the male inside of denturecap with the tip and remove.

③ Twist the tip clock-wise until the maleseparates.

P

1.5mm

G/H

Regular

P : ∅4.8 ∅4.8 x 0.7mm HSLCA4810R

∅4.8 x 2.0mm HSLCA4820R

∅4.8 x 3.0mm HSLCA4830R

∅4.8 x 4.0mm HSLCA4840R

Platform x G/H Code

D

Fixture level

1.5mm

G/H

Mini

∅3.7 x 1.0mm HGLCA3510M

∅3.7 x 2.0mm HGLCA3520M

∅3.7 x 3.0mm HGLCA3530M

∅3.7 x 4.0mm HGLCA3540M

∅3.7 x 5.0mm HGLCA3550M

Diameter x G/H Code

D

Fixture level

1.5mm

G/H

Standard

∅3.7 x 1.0mm HGLCA4010S

∅3.7 x 2.0mm HGLCA4020S

∅3.7 x 3.0mm HGLCA4030S

∅3.7 x 4.0mm HGLCA4040S

∅3.7 x 5.0mm HGLCA4050S

Diameter x G/H Code

LOCATOR�

Lab Analog (4Pack)

LAL40S

LCCT

LOCATOR� Torque Driver

TWLDL TWLDS

LAL50S

LOCATOR� Replacement Male (4Pack)

LRM06S

6N

LRM12S

12N

LRM22S

22N

LOCATOR� Extended Replacement Male (4Pack)

LEM06S

LOCATOR� Black Processing Male (4Pack)

LBPS

LOCATOR� Block-out Spacers (20 pack)

6N

LEM12S

12N

LBSS