Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
3.32
3.32
3.12
3.12
2.92
2.92
3.52
E
E
E
E
E
E
E
E
E
E
E
E
INVER
MAY R
OAD
HOPE STREET
BOUNDARY ALONG FACE OF BRICK WALL
BOUNDARY ALONG FACE
OF BRICK WALL
PROPOSED NEW
SHOWROOM
F.F.L.: 3.58 TO
MATCH EXISTING
UNIT 3, 2 HOPE
STREET
F.F.L.: 3.58APPROX LOCATION
REDUNDANT
TAS GAS LINE
750mm BELOW
SURFACE LEVEL
CONFIRM
BOUNDARY
BOUNDARY
BO
UND
AR
Y
BO
UND
AR
Y
BO
UND
AR
Y
FLAT 1
FLAT 2FLAT 3
P1
P2
P3
P4
P5
STORMWATER
GRATED PIT
INV. RL: 99.650
WATER
METER
ELEC
POLE
ED
GE O
F B
ITUM
EN
BACK O
F K
ER
B
TELSTRA PIT
STORMWATER
SIDE ENTRY PIT
TELSTRA PIT
STORMWATER
SIDE ENTRY PIT
ELEC
POLE
ROAD
SIGN
EDGE OF BITUMENBACK OF KERB
ELEC
POLE
BANK TOP
SEWER
MANHOLE
BURRIED
WATER METER
GATE
UNKNOWN PIT
TELSTRA PIT
EXISTING
CROSSOVER
SEWER
MANHOLE
STOP
VALVE
6304
1166 7280
NEW CROSSOVER
TO COUNCIL STANDARDS
EXISTING CROSSOVER
TO BE REMOVED
NEW KERB
EXISTING CROSSOVER
TO BE REMOVED
NEW KERB
NEW ON-STREET
PARKING
NEW ON-STREET
PARKING
2500
1200
BOL.
BO
UND
AR
Y 2
0.5
1 m
BOUNDARY 22.06 m
BO
UND
AR
Y 19
.28 m
BOUNDARY 19.56 m
B'DRY
2.57
m
EXISTING
ON-STREET
PARKING
Hotondo Homes John Dykman68 Pomona Road, Riverside 7250Ph: 03 6327 2219
LEGENDBOLLARD TO DETAILBOL.
Drafted by: Approved By:
Scale:
Revision:
Date:
Project/Drawing No:
Drawing:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Project:
Client name:
10 Goodman Court, Invermay Tasmania 7248, p+ 03 6332 3790 f+ 03 63323789 [email protected] primedesigntas.com.auAccredited building practitioner: Frank Geskus No CC246A
As indicated
ApproverAuthor
SITE PLAN
PD18136- 01
15-02-2018
PLANNING
PROPOSED NEW SHOWROOM303-305 INVERMAY ROAD & UNIT3/2 HOPE STREET,INVERMAY
HOTONDO HOMES
08
1 : 200
SITE PLAN
GENERAL NOTES
• CHECK & VERIFY ALL DIMENSIONS & LEVELS ON SITE
• WRITTEN DIMENSIONS TO TAKE PREFERENCE OVER
SCALED
• ALL WORK TO BE STRICTLY IN ACCORDANCE WITH
NCC, ALL S.A.A.. CODES & LOCAL AUTHORITY BY-LAWS
• ALL DIMENSIONS INDICATED ARE FRAME TO FRAME
AND DO NOT ALLOW FOR WALL LININGS
• CONFIRM ALL FLOOR AREAS
• ALL PLUMBING WORKS TO BE STRICTLY IN
ACCORDANCE WITH A.S. 3500 & APPROVED BY
COUNCIL INSPECTOR
• BUILDER/PLUMBER TO ENSURE ADEQUATE FALL TO
SITE CONNECTION POINTS IN ACCORDANCE WITH A.S.
3500 FOR STORMWATER AND SEWER BEFORE
CONSTRUCTION COMMENCES
• THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
THE ENGINEER'S STRUCTURAL DRAWINGS
• ALL WINDOWS AND GLAZING TO COMPLY WITH A.S.
1288 & A.S. 2047
• ALL SET OUT OF BUILDINGS & STRUCTURES TO BE
CARRIED OUT BY A REGISTERED LAND SURVEYOR
AND CHECKED PRIOR TO CONSTRUCTION
• IF CONSTRUCTION OF THE DESIGN IN THIS SET OF
DRAWINGS DIFFER FROM THE DESIGN AND DETAIL IN
THESE AND ANY ASSOCIATED DOCUMENTS BUILDER
AND OWNER ARE TO NOTIFY DESIGNER
• BUILDER'S RESPONSIBILITY TO COMPLY WITH ALL
PLANNING CONDITIONS
• BUILDER TO HAVE STAMPED BUILDING APPROVAL
DRAWINGS AND PERMITS PRIOR TO COMMENCEMENT
OF CONSTRUCTION
• CONSTRUCTION TO COMPLY WITH AS 3959, READ IN
CONJUNCTION WITH BUSHFIRE ATTACK LEVEL (BAL)
ASSESSMENT REPORT.
LOCATION OF ALL SERVICES
ON SITE TO BE CONFIRMED BY
SURVEYOR
SITE DETAIL
HORIZONTAL DATUM IS ARBITRARY
VERTICAL DATUM IS ARBITRARY
WARNINGS:
THE DETAIL SHOWN / RECORDED
• MAY ONLY BE CORRECT AT THE DATE OF SURVEY.
• IS NOT A COMPLETE REPRESENTATION OF ALL SURFACE AND
UNDERGROUND DETAIL.
• SHOULD ONLY BE USED FOR THE PURPOSES INTENDED.
THE LOCATIONS OF UNDERGROUND SERVICES ARE
APPROXIMATE ONLY AS INDICATED BY SURFACE FEATURES.
PRIOR TO ANY CONSTRUCTION REFER TO RELEVANT AUTHORITIES
FOR DETAILED LOCATION OF ALL SERVICES.
CONTOUR INTERVAL 0.??m
Version: 1, Version Date: 21/02/2019Document Set ID: 3994838
3.32
3.32
3.12
3.12
2.92
2.92
3.52
E
E
E
E
E
E
E
E
E
E
E
E
E
INVER
MAY R
OAD
HOPE STREET
BOUNDARY
BOUNDARY
BO
UND
AR
Y
BO
UND
AR
Y
BO
UND
AR
Y
FLAT 1
FLAT 2FLAT 3
STAGE 1
ALTERATIONS TO
EXISTING BUILDING
PARKING TO STAY
AS EXISTING
STAGE 2
PROPOSED NEW
SHOW ROOM
& NEW CARPARKING
Hotondo Homes John Dykman68 Pomona Road, Riverside 7250Ph: 03 6327 2219
Drafted by: Approved by:
Scale:
Revision:
Date:
Project/Drawing no:
Drawing:
Project:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Client name:
Accredited building practitioner: Frank Geskus -No CC246A
10 Goodman Court, Invermay Tasmania 7248, p+ 03 6332 3790 f+ 03 63323789 [email protected] primedesigntas.com.au
As indicated
ApproverAuthor
STAGING PLAN
PD18136- 02
15-02-2018
PROPOSED NEW SHOWROOM303-305 INVERMAY ROAD & UNIT3/2 HOPE STREET,INVERMAY
PLANNING
HOTONDO HOMES
08
1 : 200
STAGING PLAN
Version: 1, Version Date: 21/02/2019Document Set ID: 3994838
3.32
3.32
3.12
3.12
2.92
2.92
3.52
E
E
E
E
E
E
E
E
E
E
E
E
E
INVER
MAY R
OAD
HOPE STREET
PROPOSED NEW
SHOWROOM
328m2
UNIT 3, 2 HOPE
STREET
F.F.L.: 3.58
BOUNDARY
BOUNDARY
BO
UND
AR
Y
BO
UND
AR
Y
BO
UND
AR
Y
FLAT 1
FLAT 2FLAT 3
P1
P2
P3
P4
P5
NEW CROSSOVER
TO COUNCIL STANDARDS
EXISTING CROSSOVER
TO BE REMOVED
NEW KERB
EXISTING CROSSOVER
TO BE REMOVED
NEW KERBNEW ON-STREET
PARKING
260
0
5400
NEW ON-STREET
PARKING
EXISTING
ON-STREET
PARKING
SHRUBS 1000-1500
-GREVILLIA SERICEA
-GREVILLIA SP
GRASSES
-LOMANDRA LONGIFOLIA
-"FAN FLOWER" SCAEVOLA SP
MULCH
-'BOYER BARK' OR SIMILAR
LEGEND
Hotondo Homes John Dykman68 Pomona Road, Riverside 7250Ph: 03 6327 2219
Drafted by: Approved by:
Scale:
Revision:
Date:
Project/Drawing no:
Drawing:
Project:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Client name:
Accredited building practitioner: Frank Geskus -No CC246A
10 Goodman Court, Invermay Tasmania 7248, p+ 03 6332 3790 f+ 03 63323789 [email protected] primedesigntas.com.au
As indicated
ApproverAuthor
LANDSCAPING PLAN
PD18136- 03
15-02-2018
PROPOSED NEW SHOWROOM303-305 INVERMAY ROAD & UNIT3/2 HOPE STREET,INVERMAY
PLANNING
HOTONDO HOMES
08
1 : 200
SITE LANDSCAPING PLAN
SITE LANDSCAPING
FRONTAGE LANDSCAPE AREA 96.56m2
/FRONTAGE AREA 217.54m2
= 0.4439
LANDSCAPE AREA OF FRONTAGE
44.39%
Version: 1, Version Date: 21/02/2019Document Set ID: 3994838
REMOVE EXISTING WALL
REMOVE EXISTING WALL
REMOVE EXISTING ENTRY DOOR
REMOVE EXISTING DOOR
EXISITNG BUILDING
EX. SEWER
MANHOLE
PROPOSED REMOVAL
Hotondo Homes John Dykman68 Pomona Road, Riverside 7250Ph: 03 6327 2219
Drafted by: Approved by:
Scale:
Revision:
Date:
Project/Drawing no:
Drawing:
Project:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Client name:
Accredited building practitioner: Frank Geskus -No CC246A
10 Goodman Court, Invermay Tasmania 7248, p+ 03 6332 3790 f+ 03 63323789 [email protected] primedesigntas.com.au
1 : 100
ApproverAuthor
DEMOLITION PLAN
PD18136- 04
15-02-2018
PROPOSED NEW SHOWROOM303-305 INVERMAY ROAD & UNIT3/2 HOPE STREET,INVERMAY
PLANNING
HOTONDO HOMES
08
1 : 100
DEMOLITION PLAN
DEMOLITION NOTE:
• IT IS THE BUILDERS RESPONSIBILTY THAT ALL
WORKS TO BE DONE IN A SAFE MANNER.
• BUILDER TO PROP WHERE REQUIRED. IF UNSURE
CONTACT ENGINEER OR DESIGNER.
• CAP ALL PLUMBING.
• ALL ELECTRICAL TO BE DISCONNECTED AT MAINS
BOARD/STREET 1 OF FEED INTO SITE.
• BUILDERS RESPONSIBILITY TO KEEP SITE CLEAN
TO ENSURE NO CONTAMINATES GO INTO STORM
WATER/SEWER WATER LINES.
Version: 1, Version Date: 21/02/2019Document Set ID: 3994838
290
090
TOOL STOREPAUL OFFICEACCESSIBLE WC
MEETIN
G
RO
OM
LUNCH
JOHN OFFICE
STORE
RECEPTION
STAGE 1 STAGE 2
1120
SHOW ROOM
3620 90 1750 90 2450 90 4952
EXISITNG BUILDING
3570 90 16880 90
3539
SIGNAGE
1700
20
04574
1237
COURTYARD
2320
6420
SAM OFFICEROWAN
OFFICE
10920
880
90 3700 90 3700 90 3000 90 13790 90
12374 4812 3000 13880
BH
360
0
60
011
1460
0JOINERY/PHOTOCOPIER
100
0
2690
S/D
16835
240
12430
90
360
090
2320
90
6330
CONFIRM
CONFIRM
1 2 4
3
5 6
87
CONFIRM
100
0
3180
40
0
1120 2585
1120
Hotondo Homes John Dykman68 Pomona Road, Riverside 7250Ph: 03 6327 2219
1 : 100
GROUND FLOOR PLAN
Drafted by: Approved By:
Scale:
Revision:
Date:
Project/Drawing No:
Drawing:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Project:
Client name:
10 Goodman Court, Invermay Tasmania 7248, p+ 03 6332 3790 f+ 03 63323789 [email protected] primedesigntas.com.auAccredited building practitioner: Frank Geskus No CC246A
1 : 100
ApproverAuthor
FLOOR PLAN
PD18136- 05
15-02-2018
PLANNING
PROPOSED NEW SHOWROOM303-305 INVERMAY ROAD & UNIT3/2 HOPE STREET,INVERMAY
HOTONDO HOMES
08
Version: 1, Version Date: 21/02/2019Document Set ID: 3994838
FLOOR3580
CEILING
360
0
APPR
OX.
5436
644
F. F. F. F. F. F.
APPR
OX.
5957
E.S.L.
STREETSCAPE
EXTENSION GLAZED AREA 28.77m2 /EXTENSION
FACADE AREA 70.21m2
= 0.4098
TOTAL GLAZED AREA 40.98%
7150
290
610
290
30
00
F. F.
FLOOR3580
CEILING
360
0
APPR
OX.
3990
APPR
OX.
5435
F. F. F.F. F. F. F.
PROPOSED NEW FACADE
EXISTING BUILDING
E.S.L.
F.S.L.
STREETSCAPE
EXTENSION GLAZED AREA 52.91m2 /EXTENSION
FACADE AREA 107.68m2
= 0.4914
TOTAL GLAZED AREA 49.14%
220 2685 220
270
650
270
30
00
131382910
580
0
1700
E.S.L.
F.S.L.
Hotondo Homes John Dykman68 Pomona Road, Riverside 7250Ph: 03 6327 2219
1 : 100
EASTERN ELEVATION
Drafted by: Approved By:
Scale:
Revision:
Date:
Project/Drawing No:
Drawing:
NO
TE
: D
O N
OT
SC
AL
E O
FF
DR
AW
ING
S
Project:
Client name:
10 Goodman Court, Invermay Tasmania 7248, p+ 03 6332 3790 f+ 03 63323789 [email protected] primedesigntas.com.auAccredited building practitioner: Frank Geskus No CC246A
1 : 100
ApproverAuthor
ELEVATIONS
PD18136- 06
15-02-2018
PLANNING
PROPOSED NEW SHOWROOM303-305 INVERMAY ROAD & UNIT3/2 HOPE STREET,INVERMAY
HOTONDO HOMES
08
1 : 100
SOUTHERN ELEVATION
EXISTING EXTENSION ENTRANCE FROM
HOPE STREET
DISPLAY AREA
DISPLAY AREA DISPLAY AREA
BUILDING FASCIA
SIGN 1
BUILDING FASCIA
SIGN 2
1 : 100
SIGN ELEVATION
BLADE SIGN
SIGN 3
Version: 1, Version Date: 21/02/2019Document Set ID: 3994838
Version: 1, Version Date: 21/12/2018Document Set ID: 3957641Version: 1, Version Date: 21/02/2019Document Set ID: 3994838
Version: 1, Version Date: 21/12/2018Document Set ID: 3957641Version: 1, Version Date: 21/02/2019Document Set ID: 3994838
Version: 1, Version Date: 21/12/2018Document Set ID: 3957641Version: 1, Version Date: 21/02/2019Document Set ID: 3994838