Upload
jane-tate
View
213
Download
0
Embed Size (px)
Citation preview
LNGS Scanning Station
Nicola D’Ambrosio (LNGS group)
Maiori, 4-6 June 2007
CS Scanning Station: presently activities
• CSd measurement and analysis
• On-Line and off-line ESS improvements (New Filters, brick X-ray measurement, …)
• CS Scanning improvements (soft../Hard…)
• CS X-Ray system development and
management
• Automatic emulsion changer (oil option)
development
• Bricks / CS handling and shipment
organization …
• General maintenance (lab environment, network,
processing PCs)
• PENAUT analysis
Scanning station: April 2007 run
2 shifts/day - 1 Physicist /shift (LNGS people available and on-call)
4 microscopes dedicated : used only 3 (1 microscope had a camera problem, now solved)
- 1 microscope used for PENAUT analysis -
- 1 microscope at TecnoCut for automatic changer tuning -
Week 20Week 20
14-20 May14-20 MayWeek 21Week 21
21-27 May21-27 MayWeek 22Week 22
28-1 May-June28-1 May-June
MarilisaMarilisa AlessandraAlessandra FrancescoFrancesco
LucaLuca AndreaAndrea
Scanning station shifts List(April 2007 Run)
A new call is under way for 1÷2 weeks in June
CSd measurement started on 17/5
Scanning station CSd analysis(April 2007 Run)
• 18 CSd measured from first extraction
• 19 CSd measured from second extraction
37 CSd in 11 Days
(36÷15 cm2 around prediction)
Detailed results of this analysis will be presented by
Luillo
On-Line scanning parameters tuning needed on “real” CSd emulsion
No information on efficiencies for “large angle” ( > 400 mrad)
We need a new set of emulsion for efficiencies check• using “presently” CSd-like emulsion + large angle set
New test beam ?
Comments
Scanning station : 2007 September Run24 hours/day
6 microscopes operative
3 shifts/day (8 hours) - 2 person/shift (1 Physicist from the collaboration,
1 ext. man power )
~ 1 CSd / system / day (considering also NC)
In total 6÷8 CSd/day can be analyzed at LNGS
Scanning station : near future plan
Setting Up of the CS Analysis parameters(On-Line and Off-Line)
Re-Measurement of the CSd (April 2007 run)
A soon as they are available -> tuning of the other 3 microscopes
Tuning of the data flow into the computer infrastructure
(Data access via Central DB !!!)
Emulsion
ScotchTape
Vacuum channelCSD full surface analysis: Emulsion on scotch
tape
CSD full surface analysis
• Preliminary quality test DONE : CSD prediction from August Run measured and confirmed
Event found 98 times on 100 measurements
Future tests: new scotch, un-gluing emulsion effects, precise measurement near the border.
• Presently we manually glue the emulsion on scotch with a “simple tool”: not so easy to get good result
• Professional gluing machine will be soon available (Bologna)
• New prototype of glass with large perimeter channel is under construction (Bologna)