L M S / L M I 4 0 0U s e r S o f t w a r e
N e w f u n c t i o n s f r o mV e r s i o n 4 . 1 u p t o V e r s i o n 5 . 1
Supplement to the OI
LMS/LMI 400 User Software
Contents1 Common changes .................................................................................................................3
1.1 Translating to 32-Bit............................................................................................................ 3
1.2 Change of fields.................................................................................................................... 3
2 New LMS type ........................................................................................................................42.1 New LMS type “LMS special type 90°/0.5°“ ............................................................ 4
3 “LMS-CONFIGURATION“ menue .............................................................................................53.1 New: Real time indices....................................................................................................... 5
3.2 New: Contour on plain........................................................................................................ 6
3.3 Available levels...................................................................................................................... 8
4 Teach-In ....................................................................................................................................94.1 Automatic Teach-In.............................................................................................................. 9
4.2 Teach-In ................................................................................................................................... 9
5 “SICK DIAGNOSIS“ menue .................................................................................................. 105.1 New: Operating and switch-on counter .................................................................... 10
5.2 New telegram: Examining all logical levels of the output ................................... 11
Windows 95TM/98TM and Windows NTTM/2000TM are registered trademarks or trademarks
of the Microsoft Corporation in the USA and other countries.
2 © SICK AG · Division Auto Ident · Germany · All rights reserved 8 010 121/M814/18-10-2002
Supplement to the OI Chapter 1
LMS/LMI 400 User Software
Common changes
1 Common changes
1.1 Translating to 32-Bit
The User software has been translated into a 32 Bit version. A operating system WIN 95TM
or higher is required. The advantages are:
• Long file names possible
• Firmware downloads are possible with WIN-NTTM systems
• Using WIN-NTTM it is no longer necessary to change the process prioraty.
• 32- Bit Programs are faster on 32-Bit Operating Systems.
• In case of a program crash 32-Bit programs are easier to handle from the operating
system.
• The program has the look and feel of a 32-Bit Program
• Multiple instances of the program are possible therefore multiple devices can be
connected over different ports simulitaneously.
• Smoother communications.
• Win 9XTM allows parallel use of other programs.
1.2 Change of fields
Editing the fields can be facillated by using the mouse to ’Click & Drag’ thus creating a
rectangular selection area. All field points are thereby selected at once.
8 010 121/M814/18-10-2002 © SICK AG · Division Auto Ident · Germany · All rights reserved 3
Chapter 2 Supplement to the OI
LMS/LMI 400 User Software
New LMS type
2 New LMS type
2.1 New LMS type “LMS special type 90°/0.5°“
The LMS IBS supports the version LMS Special 90°/0,5°. The sensor has a 90° view and a
0,5 ° angular resolution. For one scan 13.32 ms are needed.
In the LMS IBS the sensor is described by "LMS special type 90°/0.5° configuration"
When this sensor is selected all menu items inclusive to LMS Type 6 and all menu items and
functions relating to field evaluation are deactivated. The assistant is not available with this
selection.
For this device type there are only three tabs (Sensor , In-/Outputs, Extras) avaiable in the
’Configuration’ window (LMS → Configuration → Edit).
Under the Sensor tab only the type of sensor is displayed and can not be changed.
Under the list item MEASUREMENT MODE the user is able to define how many bits are used for
the measurement value.
• 13 bits for the measurement range of 8/80 meter
• 14 bits for the measurement range of 16/160 meter
• 15 bits for the measurement range of 32/320 meter
This sensor does not have flags.
4 © SICK AG · Division Auto Ident · Germany · All rights reserved 8 010 121/M814/18-10-2002
Supplement to the OI Chapter 3
LMS/LMI 400 User Software
“LMS-CONFIGURATION“ menue
The tab IN-/OUTPUTS replaced tab RESTART of the standard sensors. Under this tab only the
master-slave functionality can be configured since the special sensor type does not support
field applications.
Under the EXTRAS the parameters are the same as those for the standard sensor.
3 “LMS-CONFIGURATION“ menue
3.1 New: Real time indices
LMS → CONFIGURATION → EDIT → SENSOR
It is possible to send indices for scans and transmitted telegrams with the request for the
measurement values. There is no further influence on the LMSIBS user software.
8 010 121/M814/18-10-2002 © SICK AG · Division Auto Ident · Germany · All rights reserved 5
Chapter 3 Supplement to the OI
LMS/LMI 400 User Software
“LMS-CONFIGURATION“ menue
3.2 New: Contour on plain
LMS → CONFIGURATION → EDIT → CONTOUR
For the outdoor devices LMS 211/221/291 there is an additional function for CONTOUR AS
REFERENCE avaiable.
Most reference contours are straight. To get a parallel contour band around a straight plane
the function CONTOUR AS REFERENCE has been expanded with the option CONTOUR ON PLANE.
The function used in the past was RADIAL.
Attention!
The laser scanners LMS 200/220 only accept RADIAL
Pitch angle
If the option CONTOUR ON PLAIN is selected there is (under SETTINGS) the possibility to set the
angle at which the LMS is installed relative to reference plane. 0° means the scanner back
plane is parallel to the reference plane. The angle is the so called ’pitch angle’. The pitch
angle is selectable between + 90° and - 90°. Note that the LMS scanner is scanning
counterclockwise. Every scan beam has a defined angle to the back plane. The 90° scan
beam is perpendicular to the back plane of the LMS. At a pitch angle of 0° the 90° scan
beam is perpendicular to the reference plane.
At +10° pitch angle of the scanner (scan is counter clockwise top view) the 80° scan beam
is the new perpendicular to the reference plane.
6 © SICK AG · Division Auto Ident · Germany · All rights reserved 8 010 121/M814/18-10-2002
Supplement to the OI Chapter 3
LMS/LMI 400 User Software
“LMS-CONFIGURATION“ menue
The function CONTOUR AS REFERENCE should only be used if the working angle around the
perpendicular to the contour plane stays within + 70° and - 70°.
As a example:
• Pitch Angle 0° creates a maximum start angle for contour as reference of 20° and a stop
angle of 160°• Pitch Angle 10° creates a maximum start angle for contour as reference of 10° and a
stop angle of 150°• Pitch Angle -10° creates a maximum start angle for contour as reference of 30° and a
stop angle of 170°Since this function is not available on the scanners LMS 200/220 the pitch angle must be
set to 0°.
8 010 121/M814/18-10-2002 © SICK AG · Division Auto Ident · Germany · All rights reserved 7
Chapter 3 Supplement to the OI
LMS/LMI 400 User Software
“LMS-CONFIGURATION“ menue
3.3 Available levels
LMS → CONFIGURATION → EDIT → EXTRAS
In this window the available levels can be selected. These levels implement, among other
things, the response to dazzling.
Dazzling explaned: Scanners of the LMS series work on the pulse travelling time with an emitting light source of
905 nm. Direct exposure to sun light or similar light sources leads to dazzling at a certain
angle. There is no measurement possible by a dazzled beam. The dazzled beam is marked
in the scanner.
The factory settings of all LMS scanners are at Level 1.
3.3.1 Availability level 1
Level 1 indicates that a dazzled beam is interpreted as a field infringement.
The dazzling is temporarily ignored until the number of scans, specified by MAXIMUM DURATION
OF DAZZLING is reached at which point a field infringement is reported. Within the input window
the user can set the number of scans required to activate this level. A scan is 13.32 ms.
1 to 255 scans can be selected. (13.32 ms to 3.4 s). Default is 2 scans.
3.3.2 Availability level 2
Level 2 indicates that a dazzled beam does not affect the field functionality. The beam is
ignored.
3.3.3 Availability level 3
Level 3 is not related to dazzling. It is related the previously delivered LMS hardware (Typ
1-5). These are devices that can not be delivered anymore and are replaced by type 6
scanners. Since the LMS scanners are regularly upgraded some parameters have different
defaults. To assure full compatibility to types 1-5 scanners this menu point can be selected.
If selected the differences are:
• During regular self testing of the scanners the dazzling results in an info message instead
an error.
• The contamination level is set to be active at 50% instead of 25%
• An error in the reference channels for contamination results in an info message instead
an error.
• The detection of oil contamination results in an info message instead a warning/error.
• At the loss of synchronization with a slave configuration of the LMS scanner results in an
info message instead an error.
8 © SICK AG · Division Auto Ident · Germany · All rights reserved 8 010 121/M814/18-10-2002
Supplement to the OI Chapter 4
LMS/LMI 400 User Software
Teach-In
4 Teach-In
4.1 Automatic Teach-In
LMS → MONITORED FIELD → TEACH-IN (F5)
For automatic teach-in of fields a separate window gives the possibility to set a specified
distance between the defined field borders and the reference. The field is made shorter than
the given distance. The default is 70mm. Values between 50 and 400 mm can be selected.
4.2 Teach-In
LMS → MONITORED FIELD → REFLECTOR TEACH-IN (F5)
or with the quick button in the tool bar
8 010 121/M814/18-10-2002 © SICK AG · Division Auto Ident · Germany · All rights reserved 9
Chapter 5 Supplement to the OI
LMS/LMI 400 User Software
“SICK DIAGNOSIS“ menue
If reflectors are placed at the corners of fields which have to be created those reflectors can
be used for automatic field teach in.
With the TEACH-IN WITH REFLECTORS Field A and B are always created simultaneously. For
every field taught in a contour as reference will be defined at the end.
If the LMS Sensor is a LMS 200/220 and a pixel orientated evaluation is selected it will be
reconfigured to scan oriented evaluation with the appropriate message.
Attention:
The function teach in by reflectors is only possible with the 100° view. If the LMS sensor is
configured as a 180 ° view device it will be automaticaly reconfigured with the appropriate
message.
5 “SICK DIAGNOSIS“ menue
5.1 New: Operating and switch-on counter
MEASUREMENT TECHNIQUE → SICK DIAGNOSIS
10 © SICK AG · Division Auto Ident · Germany · All rights reserved 8 010 121/M814/18-10-2002
Supplement to the OI Chapter 5
LMS/LMI 400 User Software
“SICK DIAGNOSIS“ menue
The LMS 211/221/291 are equipped with an operating counter and a switch-on counter.
Every ’switch-on’ is documented. The operating counter is triggered every two hours.
5.2 New telegram: Examining all logical levels of the output
MEASUREMENT TECHNIQUE → SICK DIAGNOSIS
By selecting the telegram 'REQUEST FOR STATE OF FIELD OUTPUTS' all logical levels of the output
can be examined.
8 010 121/M814/18-10-2002 © SICK AG · Division Auto Ident · Germany · All rights reserved 11
SICK AG · Auto Ident · Nimburger Straße 11 · 79276 Reute · Germany · www.sick.com8 0
10
12
1/M
81
4/1
8-1
0-2
00
2 · 5
M/T
R <
FM
5.5
> · S
MD
· P
rinte
d in G
erm
any
· S
ub
ject
to c
hange
witho
ut
prio
r no
tice
· A
ftE
37
05
sw
A u s t r a l i aPhone +61 3 9497 4100
(0 08) 33 48 02–toll free
Fax +61 3 9497 1187
A u s t r i aPhone +43 22 36/62 28 8-0
Fax +43 22 36/62 28 85
B e l g i u m / L u x e m b o u r gPhone +32 24 66 55 66
Fax +32 24 63 31 04
B r a z i lPhone +55 11 5561 2683
Fax +55 11 5535 4153
C h i n aPhone +85 2 2763 6966
Fax +85 2 2763 6311
C z e c h R e p u b l i cPhone +42 02-579 11 850
+42 02-578 10 561
Fax +42 02-578 10 559
D e n m a r kPhone +45 45 82 64 00
Fax +45 45 82 64 01
F i n l a n dPhone +358 9-728 85 00
Fax +358 9-72 88 50 55
F r a n c ePhone +33 1 64 62 35 00
Fax +33 1 64 62 35 77
G e r m a n yPhone (+49 2 11) 53 01-0
Fax (+49 2 11) 53 01-1 00
G r e a t B r i t a i nPhone +44 17 27-83 11 21
Fax +44 17 27-85 67 67
I t a l yPhone +39 02-92 14 20 62
Fax +39 02-92 14 20 67
J a p a nPhone +81 3 3358 1341
Fax +81 3 3358 0586
K o r e aPhone +82 2 786 6321/4
Fax +82 2 786 6325
N e t h e r l a n d sPhone +31 30 229 25 44
Fax +31 30 229 39 94
N o r w a y
Phone +47 67 56 7500
Fax +47 67 56 6100
P o l a n dPhone +48 22 837 40 50
Fax +48 22 837 43 88
S i n g a p o r ePhone +65 67 44 37 32
Fax +65 68 41 77 47
S p a i nPhone +34 93 4 80 31 00
Fax +34 93 4 73 44 69
S w e d e nPhone +46 8-680 64 50
Fax +46 8-710 18 75
S w i t z e r l a n dPhone +41 41 61 92 93 9
Fax +41 41 61 92 92 1
T a i w a nPhone +886 2 2365-6292
Fax +886 2 2368-7397
U S APhone +1(781) 302-2500
Fax +1(781) 828-3150
Representatives and agencies in
all major industrial countries.