Report No.:GZE161180-B Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 AddressStandard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 1 / 15 NVLAP LAB CODE 201011-0 LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,Futian District,Shenzhen,China Architectural Flood and Spot Luminaires Model name(s): 57-150W-XXK-FL-XT15 Representative (Tested) Model:57-150W-30K-FL-XT15 57-150W-57K-FL-XT15 Model Different: All construction and rating are the same, except CCT Test & Report By: Review By: Jack Luo Engineer: Jack Luo Manager: Tommy Liang Date:Dec.02,2016 Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.

LM-79-08 Test Report › cf73a1a2 › files... · 2019-12-10 · Model Number 57-150W-XXK-FL-XT15 SKU (if available) N/A Type of Luminaire (for integral lamps, list base type and

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

1 / 15

NVLAP LAB CODE 201011-0

LM-79-08 Test Report

For

Builders Pack(Brand Name: Builders Pack)

ShenFuBao Industry Park,Bonded area,Futian District,Shenzhen,China

Architectural Flood and Spot Luminaires

Model name(s): 57-150W-XXK-FL-XT15

Representative (Tested) Model:57-150W-30K-FL-XT1557-150W-57K-FL-XT15

Model Different: All construction and rating are the same, except CCT

Test & Report By: Review By:

Jack Luo Engineer: Jack Luo Manager: Tommy Liang

Date:Dec.02,2016

Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or

any agency of the Federal Government.

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

2 / 15

1.1 Product Information:

Organization Name Builders PackBrand Name Builders PackModel Number 57-150W-XXK-FL-XT15SKU (if available) N/A

Type of Luminaire

(for integral lamps, list base type and lamp type) Architectural Flood and Spot Luminaires

Rated Voltage / Frequency 100 -277Vac, 50/60 Hz

Nominal Power 150W

Rated Initial Lamp Lumen --

Declared CCT 3000K,3500K,4000K,4500K,5000K,5700K

LED Manufacturer Guangzhou Hongli Opto-Electronic Co., Ltd.

LED Model HL-AT-2835FVW-S1-08-PCT-HR3

Sample Number GZE161180-B1(3000K),B2(5700K)

Luminaire Aperture (for downlights) -- in.

Luminaire Length -- mm

Luminaires Width -- mm

Number of Units (modular products) N/A s

Photo

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

3 / 15

1.2 Test Specifications:

Date of Receipt Nov.23,2016

Date of Test Nov.24,2016

Test item

1. Total Luminous Flux

2. Luminous Distribution Intensity

3. Luminous Efficacy

4. Correlated Color Temperature

5. Color Rendering Index

6. Chromaticity Coordinate

7. Electrical Parameters

Reference Standard

1. IES LM-79-2008 Electrical and Photometric Measurements of

Solid-State Lighting Products

2. ANSI C78.377-2008 Specifications for the Chromaticity of Solid

State Lighting Products

3. CIE 13.3-1995 Method of Measuring and Specifying Colour

Rendering Properties of Light Sources

4. CIE 15-2004 Technical Report Colorimetry

5. IESNA LM-16-93 Practical Guide to Colorimetry of Light Source

6. IESNA TM-16-05 Technical Memorandum on Light Emitting

Diode (LED) Sources and Systems

Reference Work Instruction QD25

1.3 Test Methods

1) Photometric and Light Distribution Measurement – Goniophotometer Method:

Photometric parameters were measured using the goniophotometer and software. The ambient

temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from the

sample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz.

It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were

calculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.

2) Chromaticity Measurement – Sphere-Spectroradiometer Method:

Chromaticity parameters were measured using an integrating sphere, a spectroradiometer and software.

The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample

measurements were made using a spectroradiometer connected by a fiber optic cable and detector

through the detector port of the integrating sphere. The sample was operated at 120 or rated Volts AC,

60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color

temperature and color rendering index were calculated from the spectral power distribution taken at 5

nm intervals over the range of 380 to 780 nm.

3) Electrical Measurements:

Electrical parameters were measured using power meters incorporated in goniophotometer or

sphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at

25º C ± 1º C. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before

measurement was made. Voltage, frequency, current, power, power factor and total harmonic distortion

were measured by and read from the power meter.

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

4 / 15

2.1 Electrical, Photometric and Chromaticity Measurements

(Refer to Work Instruction QD25)

Test date 2016-11-24 Test Ambient: 25.2 º C

Test Orientation Horizontal Stabilization Time (min) 90

Model Number 57-150W-30K-FL-XT15

Electrical Measurement:

Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

GZE161180-

B1

120.0 60 1.160 138.0 0.9915 7.89

277.0 60 0.5408 136.1 0.9086 12.46

DLC Pass Criteria >= 0.9(-3%) <= 20(+5)

Chromaticity Measurement - Sphere-Spectroradiometer Method:

Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 78 R9 2

Frequency (Hz) 60 R2 90 R10 76

CCT (K) 2990 R3 96 R11 74

Duv 0.0002 R4 77 R12 67

Chromaticity (x, y) x=0.4380 y=0.4049 R5 78 R13 81

Chromaticity (u’, v’) u'=0.2509 v'=0.5219 R6 86 R14 98

Color Rendering Index (CRI) 80.5 R7 82 R15 72

R9 2 R8 57 -- --

Photometric Measurement – Goniophotometer Method:

Parameter Result DLC V4.0 Pass Criteria

Test Voltage (V) 120.0 277.0 --

Frequency (Hz) 60 60

Total Luminous (lm) 14376 14089 >=10000(-10%)

Luminous Efficacy (lm/W) 104.17 103.52 Standard: >=

100(-3%)

Premium: >=

120(-3%)

Zonal lumens in the 0-90° zone (%) 99.9 -- >= 85(-3)

Beam Angle (°) 102.55 -- --

Center Beam Candle Power (cd) 5956 -- --

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

5 / 15

Zonal Lumen Tabulation

Zonal Lumen Summary

Zone Lumens % Luminaire

0-30 4,705.0 32.7%

0-40 7,704.0 53.6%

0-60 13,000.1 90.4%

60-90 1,362.6 9.5%

70-100 196.0 1.4%

90-120 3.1 0%

0-90 14,362.7 99.9%

90-180 11.4 0.1%

0-180 14,374.0 100%

Lumens Per Zone

Zone Lumens % Total Zone Lumens % Total

0-10 566.3 3.9% 90-100 1.0 0%

10-20 1,633.8 11.4% 100-110 0.9 0%

20-30 2,504.9 17.4% 110-120 1.3 0%

30-40 2,999.0 20.9% 120-130 1.5 0%

40-50 2,965.1 20.6% 130-140 1.8 0%

50-60 2,330.9 16.2% 140-150 1.8 0%

60-70 1,167.6 8.1% 150-160 1.6 0%

70-80 179.8 1.3% 160-170 1.1 0%

80-90 15.3 0.1% 170-180 0.4 0%

Spectral Power Distribution & Chromaticity Diagram

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

6 / 15

Photometric Data

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

7 / 15

Candela Table - Type C

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

0 5956 5956 5956 5956 5956 5956 5956 5956 5956 5956 5956 5956 5956 5956 5956 5956 5956

1 5952 5959 5966 5982 6000 5923 5929 5944 5957 5972 5977 5991 6000 5924 5926 5931 5952

2 5947 5955 5956 5976 6002 5930 5936 5952 5975 5985 5980 5995 6001 5925 5927 5924 5947

3 5928 5938 5948 5974 6000 5929 5943 5955 5984 5995 5986 5993 5997 5921 5920 5915 5928

4 5913 5925 5940 5966 5993 5924 5950 5955 5984 5996 5990 5993 5996 5917 5909 5906 5913

5 5903 5904 5926 5965 5987 5918 5952 5953 5975 5989 5986 6005 6002 5909 5895 5895 5903

6 5882 5892 5913 5959 5993 5926 5940 5945 5967 5986 5986 6012 6003 5907 5885 5868 5882

7 5860 5871 5902 5958 6003 5933 5929 5935 5956 5976 5990 6012 5998 5906 5873 5844 5860

8 5833 5851 5890 5954 6002 5936 5932 5923 5940 5964 5993 6009 5990 5895 5865 5820 5833

9 5811 5828 5870 5948 5988 5932 5930 5912 5919 5940 5986 6005 5983 5889 5848 5808 5811

10 5779 5804 5861 5932 5980 5923 5925 5884 5900 5923 5973 6000 5981 5882 5834 5778 5779

11 5747 5773 5844 5916 5971 5908 5908 5863 5876 5906 5959 5990 5972 5872 5816 5756 5747

12 5708 5745 5826 5899 5963 5903 5894 5834 5836 5884 5940 5974 5953 5857 5798 5720 5708

13 5678 5701 5801 5885 5948 5897 5878 5805 5801 5843 5925 5963 5938 5837 5779 5690 5678

14 5629 5668 5776 5865 5939 5879 5857 5774 5759 5814 5907 5953 5936 5815 5757 5654 5629

15 5580 5622 5741 5844 5929 5871 5833 5737 5719 5781 5877 5950 5929 5802 5725 5615 5580

16 5526 5581 5711 5827 5924 5864 5808 5704 5665 5739 5853 5940 5918 5782 5680 5565 5526

17 5493 5541 5672 5809 5917 5859 5772 5668 5612 5697 5815 5935 5910 5771 5652 5531 5493

18 5440 5506 5644 5804 5907 5849 5738 5610 5565 5655 5779 5927 5902 5752 5613 5478 5440

19 5388 5467 5600 5792 5902 5836 5701 5568 5508 5599 5752 5911 5893 5736 5580 5431 5388

20 5316 5406 5555 5778 5894 5818 5673 5508 5454 5553 5718 5902 5879 5718 5536 5376 5316

21 5248 5344 5512 5764 5883 5811 5648 5461 5400 5491 5692 5888 5864 5706 5502 5328 5248

22 5186 5293 5485 5751 5869 5802 5609 5409 5326 5436 5647 5876 5858 5685 5462 5269 5186

23 5130 5225 5445 5724 5862 5782 5569 5338 5266 5385 5606 5855 5849 5668 5417 5211 5130

24 5068 5169 5409 5711 5856 5768 5519 5280 5194 5313 5569 5843 5830 5648 5371 5133 5068

25 4996 5096 5353 5695 5844 5756 5482 5211 5130 5251 5534 5830 5805 5624 5322 5081 4996

26 4928 5044 5314 5677 5814 5747 5445 5146 5062 5179 5490 5809 5773 5595 5276 5016 4928

27 4865 4985 5263 5652 5775 5717 5386 5083 4982 5121 5433 5787 5736 5565 5231 4948 4865

28 4787 4905 5216 5623 5748 5685 5337 5006 4918 5053 5383 5746 5670 5533 5174 4870 4787

29 4704 4825 5154 5581 5704 5656 5279 4943 4832 4970 5326 5698 5610 5495 5113 4804 4704

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

8 / 15

30 4639 4759 5104 5541 5637 5611 5238 4852 4763 4901 5277 5629 5531 5442 5058 4736 4639

31 4574 4688 5050 5485 5573 5562 5191 4783 4676 4814 5224 5568 5461 5392 5003 4647 4574

32 4491 4604 5006 5430 5484 5497 5127 4703 4609 4742 5157 5506 5379 5313 4938 4581 4491

33 4425 4524 4938 5354 5404 5437 5068 4634 4540 4654 5097 5417 5272 5239 4886 4505 4425

34 4337 4457 4876 5285 5301 5348 4993 4573 4463 4591 5018 5336 5186 5146 4812 4438 4337

35 4259 4388 4795 5187 5214 5267 4924 4489 4403 4525 4948 5224 5072 5063 4744 4354 4259

36 4176 4301 4731 5102 5104 5185 4839 4422 4328 4445 4857 5133 4981 4955 4662 4279 4176

37 4113 4225 4663 4996 5011 5076 4773 4348 4274 4384 4778 5006 4866 4866 4589 4187 4113

38 4030 4147 4564 4907 4919 4985 4680 4291 4196 4309 4687 4905 4762 4750 4485 4116 4030

39 3960 4079 4488 4813 4795 4868 4608 4213 4138 4252 4578 4778 4635 4655 4407 4035 3960

40 3876 3989 4396 4691 4695 4766 4530 4152 4073 4176 4491 4678 4532 4557 4309 3965 3876

41 3816 3923 4310 4589 4567 4632 4414 4075 4014 4114 4375 4569 4425 4426 4220 3877 3816

42 3757 3857 4219 4454 4464 4528 4322 4019 3937 4044 4281 4429 4295 4312 4131 3811 3757

43 3673 3765 4102 4348 4335 4400 4202 3961 3868 3982 4168 4312 4183 4177 4009 3740 3673

44 3600 3685 4010 4246 4226 4291 4111 3879 3716 3916 4072 4175 4040 4067 3913 3659 3600

45 3512 3618 3884 4114 4114 4145 3996 3816 3508 3830 3955 4064 3924 3927 3789 3579 3512

46 3449 3548 3773 4005 3977 4027 3914 3706 3433 3683 3864 3912 3788 3811 3696 3503 3449

47 3272 3454 3679 3866 3844 3910 3803 3491 3350 3449 3750 3793 3672 3665 3574 3427 3272

48 3080 3383 3585 3721 3728 3769 3707 3364 3223 3375 3656 3646 3531 3555 3475 3339 3080

49 2982 3234 3466 3608 3577 3656 3585 3293 2999 3281 3567 3527 3428 3412 3349 3234 2982

50 2913 3030 3364 3487 3471 3514 3493 3185 2926 3161 3447 3409 3309 3298 3249 2979 2913

51 2661 2915 3241 3343 3366 3390 3406 2978 2833 2922 3346 3273 3207 3190 3155 2885 2661

52 2559 2840 3151 3195 3239 3248 3289 2836 2681 2843 3221 3161 3110 3060 3035 2789 2559

53 2470 2617 3027 3091 3141 3138 3183 2758 2517 2767 3095 3032 2994 2966 2934 2611 2470

54 2295 2484 2927 2960 3014 3002 3007 2645 2447 2592 2835 2931 2891 2838 2808 2433 2295

55 2145 2386 2822 2853 2920 2894 2795 2453 2269 2421 2742 2804 2750 2734 2701 2356 2145

56 2072 2231 2679 2740 2820 2788 2685 2346 2124 2348 2615 2727 2552 2604 2573 2163 2072

57 1850 2055 2481 2619 2577 2693 2589 2249 2034 2144 2497 2594 2421 2468 2396 2027 1850

58 1774 1978 2305 2518 2412 2566 2431 2025 1863 2011 2256 2389 2282 2246 2206 1922 1774

59 1602 1759 2181 2321 2310 2396 2228 1938 1734 1906 2150 2236 2076 2149 2116 1738 1602

60 1489 1671 2049 2132 2063 2210 2100 1772 1576 1719 2039 2128 1945 1942 1971 1626 1489

61 1341 1497 1845 2031 1974 2112 1980 1619 1449 1610 1826 1902 1759 1809 1794 1484 1341

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

9 / 15

62 1222 1385 1762 1798 1760 1887 1790 1522 1314 1414 1728 1784 1637 1664 1683 1343 1222

63 1061 1223 1576 1707 1651 1789 1673 1335 1184 1323 1595 1603 1462 1499 1545 1208 1061

64 977 1119 1461 1506 1461 1594 1569 1238 1037 1143 1432 1483 1336 1372 1324 1077 977

65 813 946 1310 1405 1356 1470 1367 1065 940 1058 1265 1318 1179 1219 1183 905 813

66 679 869 1123 1218 1163 1310 1239 958 778 885 1111 1190 1030 1074 1025 816 679

67 605 720 999 1132 1075 1185 1058 835 646 790 963 1046 897 945 880 684 605

68 483 581 839 960 916 1039 906 696 565 661 800 859 771 808 751 566 483

69 384 483 702 847 777 882 778 567 439 520 680 713 629 670 610 445 384

70 280 372 595 719 644 753 630 452 337 410 562 615 521 578 510 359 280

71 198 293 459 586 514 617 539 371 233 303 446 466 401 433 396 257 198

72 130 185 369 461 420 507 415 253 146 218 334 373 309 347 311 182 130

73 118 119 270 363 298 378 323 171 124 128 262 259 209 231 224 112 118

74 103 104 191 256 213 264 232 110 108 110 181 188 113 161 165 102 103

75 87 93 138 158 123 185 158 97 96 95 118 112 58 89 111 89 87

76 75 79 86 101 57 107 111 86 83 82 80 55 47 43 67 75 75

77 62 66 57 48 45 57 66 74 72 72 54 44 42 39 49 65 62

78 52 56 47 41 41 42 50 65 61 61 47 39 37 34 41 53 52

79 42 45 40 35 36 37 42 54 50 51 40 35 33 30 37 44 42

80 32 37 33 31 31 33 35 44 43 43 34 31 30 26 30 35 32

81 26 28 27 27 28 28 31 38 35 35 30 27 26 24 25 27 26

82 20 21 23 23 24 25 26 30 28 30 25 24 23 20 19 21 20

83 15 17 18 20 21 22 22 25 24 24 22 20 20 17 16 15 15

84 10 11 14 17 17 18 18 20 19 19 18 17 16 15 13 11 10

85 6 8 10 14 14 15 15 15 16 16 14 14 14 11 10 7 6

86 4 4 7 11 11 12 12 12 12 12 11 11 10 9 7 5 4

87 2 2 4 8 9 10 9 9 9 9 9 8 7 5 4 2 2

88 1 1 2 5 5 7 7 7 6 6 5 3 3 1 0 1 1

89 1 1 1 1 1 2 3 3 2 2 2 2 2 1 1 1 1

90 1 1 1 1 1 2 2 2 2 2 2 2 2 1 1 1 1

91 1 1 1 1 1 2 2 1 1 2 2 2 2 1 0 1 1

92 1 1 1 1 1 2 1 1 1 2 2 2 2 1 1 1 1

93 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

10 / 15

94 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

95 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

96 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

97 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

98 0 0 0 1 0 1 1 1 1 1 1 1 1 1 1 0 0

99 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 0 0

100 0 0 0 1 0 1 1 1 1 1 1 1 1 1 0 0 0

101 0 0 1 1 0 1 1 1 1 1 1 1 1 1 0 0 0

102 0 0 1 1 0 1 1 1 1 1 1 1 1 1 1 1 0

103 0 0 1 1 1 1 1 1 1 1 1 1 1 1 0 1 0

104 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 1

105 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

106 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

107 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

108 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

109 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

110 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

112 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

113 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

114 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1

115 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1

116 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1

117 1 1 1 1 1 2 2 1 1 1 2 1 2 1 1 1 1

118 1 1 1 1 1 2 2 1 1 1 1 1 2 1 1 1 1

119 1 1 1 1 1 2 2 1 2 1 2 2 2 1 1 0 1

120 1 1 1 1 1 2 2 1 3 1 2 2 2 2 1 1 1

121 1 1 1 2 1 2 2 1 1 1 2 2 2 2 1 2 1

122 1 1 2 2 2 2 2 1 1 1 2 2 2 2 2 0 1

123 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1

124 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1

125 2 1 2 2 2 2 2 2 3 2 2 2 2 2 2 0 2

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

11 / 15

126 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 2

127 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

128 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

129 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

130 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

131 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2

132 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

133 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 2

134 2 2 2 2 2 2 2 2 1 2 2 2 3 2 2 2 2

135 2 2 2 2 2 3 2 2 2 2 2 2 3 2 2 2 2

136 2 2 2 2 3 3 2 2 2 2 2 2 3 2 2 2 2

137 2 2 2 2 3 3 2 2 2 2 2 2 3 2 2 3 2

138 3 2 2 3 3 3 2 2 2 2 2 3 3 2 2 3 3

139 3 2 2 3 3 3 2 2 2 2 2 3 3 2 2 3 3

140 3 2 2 3 3 3 3 2 1 2 3 3 3 3 2 2 3

141 3 2 3 3 3 3 3 2 3 3 3 3 3 3 3 3 3

142 3 2 3 3 3 3 3 2 3 3 3 3 3 3 3 3 3

143 3 3 3 3 3 3 3 3 4 3 3 3 3 3 3 3 3

144 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

145 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

146 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

147 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

148 3 3 3 3 3 3 3 3 4 3 3 3 3 3 3 3 3

149 3 3 3 3 3 3 3 3 3 3 3 3 4 3 3 3 3

150 3 3 3 3 3 3 3 3 4 3 3 3 4 3 3 3 3

151 3 3 3 3 3 3 3 3 3 3 3 3 4 3 3 3 3

152 3 3 3 3 3 3 3 3 3 3 3 3 4 3 3 3 3

153 3 3 3 3 3 3 3 3 3 3 3 3 4 3 3 3 3

154 4 3 3 3 4 3 3 3 3 3 3 3 4 3 3 3 4

155 4 3 3 3 4 4 3 3 3 3 3 3 4 3 3 3 4

156 4 3 3 4 4 4 3 3 4 3 3 3 4 3 3 4 4

157 4 3 3 4 4 4 3 3 4 3 3 3 4 3 3 4 4

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

12 / 15

158 4 3 3 4 4 4 3 3 3 3 3 3 4 3 3 4 4

159 4 3 3 4 4 4 3 3 4 4 3 3 4 3 3 4 4

160 4 3 3 4 4 4 3 3 5 4 3 3 4 4 4 4 4

161 4 4 3 4 4 4 3 3 3 4 3 3 4 4 4 4 4

162 4 4 4 4 4 4 3 3 3 4 3 4 4 4 4 4 4

163 4 4 4 4 4 4 3 4 4 4 3 4 4 4 4 4 4

164 4 4 4 4 4 4 3 3 4 4 3 4 4 4 4 4 4

165 4 4 4 4 4 4 4 4 4 4 3 4 4 4 4 4 4

166 4 4 4 4 4 4 4 4 5 4 4 4 4 4 4 4 4

167 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

168 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

169 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

170 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

171 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

172 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

173 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

174 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 5 4

175 4 4 5 5 4 4 4 4 4 4 4 4 4 4 4 5 4

176 5 4 5 5 5 4 4 4 4 4 4 4 4 5 5 5 5

177 5 5 5 5 5 5 4 4 4 5 4 4 5 5 5 5 5

178 5 4 5 5 5 5 4 4 3 5 4 4 5 5 5 5 5

179 4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 4 4

180 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

13 / 15

2.2 Electrical, Photometric and Chromaticity Measurements

(Refer to Work Instruction QD25)

Test date 2016-11-24 Test Ambient: 25.2 º C

Test Orientation Horizontal Stabilization Time (min) 90

Model Number 57-150W-57K-FL-XT15

Electrical Measurement:

Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

GZE161180-

B2

120.0 60 1.177 140.3 0.9933 7.66

277.0 60 0.5505 138.7 0.9095 13.08

DLC Pass Criteria >= 0.9(-3%) <= 20(+5)

Chromaticity Measurement - Sphere-Spectroradiometer Method:

Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 78 R9 0

Frequency (Hz) 60 R2 85 R10 64

CCT (K) 5349 R3 90 R11 79

Duv 0.0056 R4 81 R12 58

Chromaticity (x, y) x=0.3364 y=0.3556 R5 79 R13 79

Chromaticity (u’, v’) u'=0.2040 v'=0.4853 R6 80 R14 95

Color Rendering Index (CRI) 80.5 R7 87 R15 72

R9 0 R8 65 -- --

Photometric Measurement – Sphere-Spectroradiometer Method:

Parameter Result DLC V4.0 Pass Criteria

Test Voltage (V) 120.0 277.0 --

Frequency (Hz) 60 60

Total Luminous (lm) 15228 14956 >=10000(-10%)

Luminous Efficacy (lm/W) 108.54 107.83 Standard: >=

100(-3%)

Premium: >=

120(-3%)

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

14 / 15

Spectral Power Distribution & Chromaticity Diagram

NVLAP LAB CODE 201011-0

Report No.:GZE161180-B

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

15 / 15

3. Test Equipment

Equipment ID Equipment Name Last Calibration Date Next Calibration Date

ST-R-336 2 meter Integrating Sphere 2016-07-01 2017-06-30

ST-R-331 Spectral analysis system HAAS-2000 2016-07-01 2017-06-30

D204 Standard Lamp 2016-07-01 2017-06-30

PF2010 Power Meter for Integrating Sphere 2016-07-01 2017-06-30

EE-09 Goniophotometer system 2016-07-01 2017-06-30

D908S Standard Lamp 2016-07-01 2017-06-30

PF210 Power Meter for Goniophotometer 2016-07-01 2017-06-30

ST-R-181A Temperature Tester 2016-07-01 2017-06-30

Uncertainty:

Photometric Measurement (Sphere):1.74%

Chromaticity Measurement(Sphere):14.3K

Photometric Measurement(Goniophotometer):1.62%

****** END OF REPORT ******