Civic Design Review Submission - July 14, 2020
1306 - 1334 Callowhill Street
Philadelphia, PA
LLCP CALLOWHILL, LLC MULTI-FAMILY DEVELOPMENT
Table of Contents
Introduction .................................................................................................................. 3
Project Application Form ................................................................................................................ 4
Regional Location Map ................................................................................................................ 5
Site Photographs ................................................................................................................. 7
Site Connectivity and Sustainability ................................................................................................ 8
Existing Site Survey ................................................................................................................ 10
Zoning Plan ................................................................................................................ 11
Vehicular Circulation Plan ................................................................................................................... 12
Floor Plans ................................................................................................................ 13
Landscape Plan ................................................................................................................ 17
Building Elevations ................................................................................................................ 19
Building Materials ................................................................................................................ 23
Site Sections ................................................................................................................ 24
3D Massing ................................................................................................................ 26
Exterior Rendering ............................................................................................................... 27
Sustainability Questionnaire ............................................................................................................. 29Complete Streets Handbook Checklist ............................................................................................ 30
PWD Conceptual Approval ............................................................................................................ 34
PA Department of L&I Refusal/Referral Letter ............................................................................ 36
3
IntroductionLLCP Callowhill, LLC is proposing a 7-story mixed-use residential building located east of Broad Street and just north of Center City Philadelphia. The site is bounded by Callowhill Street to the north and Carlton Street to the south, with existing neighboring structures on both the east and west. The massing of the building is designed to meet the scope and scale of the Philadelphia Code.
The project includes 181 dwelling unis with a mix of studio, one-bedroom and two-bedroom unit types. The units are elevated over ground floor retail as well as a 55-spot covered parking garage accessed via Callowhill Street. Residential amenities include an outdoor courtyard deck with southern exposure, lounge and co-working spaces, and a fitness center.
Mixed-Use SummaryTotal Building Gross Floor Area...................... 184,837 SF - Retail.............................................................. 3,208 SF - Parking / Loading ....................................... 28,422 SF - Residential.................................................... 145,860 SF - Interior Amenities ...................................... 7,347 SF
Zoning DataDistrict................................................................ CMX-4Lot Area.............................................................. 34,233 SFMax FAR (500%).............................................. 171,165 SF
Page 1 of 2
CDR PROJECT APPLICATION FORM
Note: For a project appl icat ion to be considered for a Civic Des ign Review agenda,
complete and accurate submit tals must be received no later than 4 P.M. on the
submission date. A submission does not guarantee placement on the agenda of the next
CDR meet ing date.
L&I APPLICATION NUMBER: ZP-2020-00458
What is the trigger causing the project to require CDR Review? Explain briefly.
The proposed project includes more than 100,000 SF of new gross floor area and creates more than 100 new dwelling units.
PROJECT LOCATION
CONTACT INFORMATION
Planning District: Central Council District: 1
Address: 1306 – 1314 Callowhill Street 1316 – 1320 Callowhill Street 1322 – 1334 Callowhill Street
Is this parcel within an Opportunity Zone? Yes x No Uncertain If yes, is the project using Opportunity Zone Funding?
Yes x No
Applicant Name: LLCP Callowhill, LLC Primary Phone: Email:
Address:
121 S. Broad Street, Ste 1310
Philadelphia, PA 19107 Property Owner:
Kwick ParkCorp
Developer
LLCP Callowhill, LLC
Architect:
Park Facilities Inc. 1322 Callowhill Street LLC Bernardon
Page 2 of 2
SITE CONDITIONS
SITE USES
COMMUNITY MEETING
ZONING BOARD OF ADJUSTMENT HEARING
Community meeting held: Yes x No
If yes, please provide written documentation as proof.
If no, indicate the date and time the community meeting will be held:
Date: 6/8/20 Time: 7:30 PM
Present Use: Surface Parking Lot Proposed Use: 7-story mixed-use building
Area of Proposed Uses, Broken Out by Program (Include Square Footage and # of Units):
• Retail ...................................................................................... 3,208 SF
• Residential (181 Dwelling Units) ...................................... 145,860 SF
• Parking / Loading & Building Services ............................ 28,422 SF • Interior Amenity Space........................................................ 7,347 SF
• Exterior Courtyard Deck...................................................... 2,755 SF (not incl. in Bldg GSF) Total Building GSF: 184,837 SF
Proposed # of Parking Units:
• 55 parking stalls (including 2 accessible spaces and 1 van-accessible space)
Site Area: 34,233 SF Existing Zoning: CMX-4 Are Zoning Variances required? Yes x No
ZBA hearing scheduled: Yes No NA _x__
If yes, indicate the date hearing will be held:
Date: Yet to be Scheduled
LLCP Callowhill LLC Multi-Family Development
5
ProjectSite
Regional Location Map
LLCP Callowhill LLC Multi-Family Development
6
Regional Location Map - Aerial View
LLCP Callowhill LLC Multi-Family Development
7
Site Photographs
���������������������������������� ���� ���������������������������������� ��������������������������������� ���� ���������������������������������
�������������������� ���������������� ���� �������������������� ���������������� ���� �������������������� ����������������
� � ��
��������� ���
�
�������
LLCP Callowhill LLC Multi-Family Development
8
Site Connectivity & Sustainability
Site Connectivity & Sustainability
Located at 13th and Callowhill Streets, the project is ideally situated to promote sustainable design & healthy living in terms of its adjacencies to transit and open space. The project site is located less than 1/4 mile from multiple SETPA stations, including access to the Broad Street Subway Line as well as various bus stops with direct connection to over a dozen various routes. An Indego Bike Share Station is also located within a block of the project site which will compliment the on-site bike storage provided within the project. Combined, these transit opportunities will promote alternative transportation and reduce the reliance on vehicles in the area.
The proposed building is also uniquely situated within 100 meters walking distance to The Rail Park, an ongoing project seeking to convert 3-miles of abandoned elevated rail lines to urban public park. With Phase 1 of the project now open, the Rail Park will serve as an extension of proposed building amenities for future building residents.
PROJECT SITE
THE RAIL PARK
LLCP Callowhill LLC Multi-Family Development
9
Site Connectivity & Sustainability
PROJECT SITE
DEDICATED BIKE LANE (13TH STREET)
BIKE FRIENDLY STREET (CALLOWHILL ST)
RAIL PARK
LLCP Callowhill LLC Multi-Family Development
10
Existing Site Survey
UTILITY COMPANY
UTILITIES:
THE FOLLOWING COMPANIES WERE NOTIFIED BY PENNSYLVANIA ONE-CALL SYSTEM(1-800-242-1776) AND REQUESTED TO MARK OUT UNDERGROUND FACILITIES AFFECTING ANDSERVICING THIS SITE. THE UNDERGROUND UTILITY INFORMATION SHOWN HEREON IS BASEDUPON THE UTILITY COMPANIES RESPONSE TO THIS REQUEST.SERIAL NUMBER(S): 20193372185
DWG. NO.
C
1306-1334 CALLOWHILL STREETLLC CALLOWHILL LLC
COMMONWEALTH OF PENNSYLVANIA
ALTA/NSPS LAND TITLE SURVEY
67
T.P.
P.V.
REVIEWED:
FIELD CREW
DRAWN:
J.B.
12-04-2019
CL19-09FIELD BOOK NO.
FIELD BOOK PG.
FIELD DATE
A
CITY & COUNTY OF PHILADELPHIA, 5TH WARDMAP 2N24, PARCELS 85, 242, 304, 305, 318, 350, 432 & 433
SPL ORTNO
SS CO TAI ETNIO
NI, C .
OF 11B.A.R.APPROVED:
12-23-2019DATE
1"=20'SCALE
02-190281-00FILE NO.
THE
PUR
POSE
OR
IGIN
ALLY
INTE
ND
ED, W
ITH
OU
T TH
E W
RIT
TEN
PER
MIS
SIO
N O
F C
ON
TRO
L PO
INT
ASSO
CIA
TES,
INC
., IS
PR
OH
IBIT
ED.
DATE
NOT TO SCALE
NOT VALID UNLESS SEALED IN RED INK
PENNSYLVANIA PROFESSIONAL LAND SURVEYOR #SU075233JAMES ROBERT AIKEN II
NEW BRITAIN CORPORATE CENTER1600 MANOR DRIVE, SUITE 210CHALFONT, PA 18914215.712.9800 - 215.712.9802 FAXWWW.CPASURVEY.COM
VICINITY MAP
0 10 20 40 80
( IN FEET )1 inch = 20 ft.
GRAPHIC SCALE20 WARREN, NJ 908.668.0099
PER
CIT
Y PL
AN
REFERENCES:
1. MAP 2N24OF THE OFFICIAL TAX REGISTRY OF THE CITY & COUNTY OF PHILADELPHIA, COMMONWEALTH OFPENNSYLVANIA.
2. MAP ENTITLED "NATIONAL FLOOD INSURANCE PROGRAM, FIRM, FLOOD INSURANCE RATE MAP, CITY OFPHILADELPHIA, PENNSYLVANIA, PHILADELPHIA COUNTY COUNTY, PANEL 183 OF 230", COMMUNITY-PANELNUMBER 420757 0183 G, MAP REVISED: JANUARY 17, 2007.
3. MAP ENTITLED "PLAN NO. 58, THE FIRST SECTION OF THE RESURVEY, FOURTH SURVEY DISTRICT,PHILADELPHIA."
4. STREET STATUS CARDS PROVIDED BY THE CITY OF PHILADELPHIA: LC000736, LC006220, LC006597, LC006815.
5. MAP ENTITLED " CITY OF PHILADELPHIA, BOARD OF HIGHWAY SUPERVISORS, ROOM 1013 CITY HALL ANNEX"PLAN NO 13-N-3.
6. MAP ENTITLED " CITY OF PHILADELPHIA, BOARD OF HIGHWAY SUPERVISORS, ROOM 1013 CITY HALL ANNEX"PLAN NO 14-N-3.
7. MAPS ENTITLED: "PWD 102593, PWD 122826, PWD 150730, PWD 151005, PWD 214620 & PWD 323748", PROVIDEDBY THE PHILADELPHIA WATER DEPARTMENT.
8. MAP ENTITLED "PAONE CALL TICKETS# 20193372185", PROVIDED BY RCN, ISSUE DATE: 1/7/2019.
9. MAP ENTITLED " BROAD STREET CITY TRANSIT DIVISION DUCTBANK, ELECTRICAL", STAMPED PRELIMINARY,PROVIDED BY SEPTA.
10. MAP ENTITLED "ALTA/ACSM LAND TITLE SURVEY, PARKWAY CORPORATION, 1322-34 CALLOWHILL STREET, 5THWARD, PRELIMINARY", DATED 12/31/2015, BY STANTEC CONSULTING SERVICES, INC.
SOUTHBOROUGH, MA 508.948.3000
MT. LAUREL, NJ 609.857.2099MANHATTAN, NY 646.780.0411
LONG ISLAND, NY 631.580.2645
CLEAN OUT
PARKING SPACE COUNT
PAINTED ARROWS
APPROX. LOC. UNDERGROUND ELEC. LINE
APPROX. LOC. UNDERGROUND GAS LINE
GAS VALVE
WATER VALVE
OVERHEAD WIRES
AREA LIGHT
BOLLARD
SIGN
GUY WIRE
UTILITY POLE/LIGHT POLE
APPROX. LOC. UNDERGROUND TEL. LINE
UTILITY POLE
POST
DEPRESSED CURB
DEPRESSED CURB
EDGE OF PAVEMENT
UNKNOWN VALVE
EDGE OF CONC.
CHAIN LINK FENCE
ELECTRIC MANHOLE
TELEPHONE MANHOLE
UNKNOWN MANHOLE
STREET LIGHT
HYDRANT
GAS METER
TYPICAL
CATCH BASIN OR INLET
WATER MANHOLE
EXIST. GUTTER ELEVATION
EXISTING SPOT ELEVATION
EXIST. TOP OF CURB ELEVATION
EXISTING CONTOUR
LEGEND
SOLID YELLOW LINE
HEIGHT DASHED YELLOW LINE
BUILDING
SOLID BLUE LINE
DOUBLE YELLOW LINE
10
NOTES:
1. PROPERTY KNOWN AS MAP 2N24, PARCELS 85, 242, 304, 305, 318, 350, 432 AND 433, AS IDENTIFIED ON THE TAXREGISTRY OF THE CITY & COUNTY OF PHILADELPHIA, COMMONWEALTH OF PENNSYLVANIA.
2. AREA (P.D.S.) = 34,063.4 S.F. OR 0.78199 A.C.AREA (U.S.S.) = 34,233.9 S.F. OR 0.78590 A.C.
3. LOCATION OF UNDERGROUND UTILITIES ARE APPROXIMATE. LOCATIONS AND SIZES ARE BASED ON UTILITYMARK-OUTS, ABOVE GROUND STRUCTURES THAT WERE VISIBLE & ACCESSIBLE IN THE FIELD, AND THE MAPSAS LISTED IN THE REFERENCES AVAILABLE AT THE TIME OF THE SURVEY. AVAILABLE AS-BUILT PLANS ANDUTILITY MARKOUT DOES NOT ENSURE MAPPING OF ALL UNDERGROUND UTILITIES AND STRUCTURES.BEFORE ANY EXCAVATION IS TO BEGIN, ALL UNDERGROUND UTILITIES SHOULD BE VERIFIED AS TO THEIRLOCATION, SIZE AND TYPE BY THE PROPER UTILITY COMPANIES. CONTROL POINT ASSOCIATES, INC. DOESNOT GUARANTEE THE UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA EITHER IN SERVICE ORABANDONED.
4. THIS PLAN IS BASED ON INFORMATION PROVIDED BY A SURVEY PREPARED IN THE FIELD BY CONTROL POINTASSOCIATES, INC. AND OTHER REFERENCE MATERIAL AS LISTED HEREON.
5. THIS SURVEY IS PREPARED WITH REFERENCE TO A TITLE REPORT PREPARED BY FIDELITY NATIONAL TITLE INSURANCE COMPANY, COMMITMENT NO. PAFN19-2216 GD, WITH AN EFFECTIVE DATE OF 05/15/2019. WHERE THE FOLLOWING SURVEY RELATED EXCEPTIONS APPEAR IN SCHEDULE B, PART II:
(FOR PREMISES B, C & D ONLY)
9. EXCEPTIONS AND RESERVATIONS AS IN DEED BOOK LRB 92 PAGE 397. - LOCATED ON SUBJECT PROPERTY, SHOWN ON PLAN.
6. THE EXISTENCE OF UNDERGROUND STORAGE TANKS, IF ANY, WAS NOT KNOWN AT THE TIME OF THE FIELDSURVEY.
7. ELEVATIONS ARE BASED UPON PHILADELPHIA CITY PLAN DATUM. HELD SOUTHWEST CORNER OFCALLOWHILL STREET AND 13TH STREET.
TEMPORARY BENCH MARKS SET:TBM-A: MAG NAIL SET IN CONCRETE WALK.
ELEVATION=36.26
TBM-B: MAG NAIL SET IN CONCRETE WALK. ELEVATION=39.81
8. BY GRAPHIC PLOTTING ONLY, THIS PROPERTY IS LOCATED IN FLOOD HAZARD ZONE 'X' (AREAS DETERMINEDTO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN) PER REF. MAP #2.
9. UNDERGROUND STORM SEWER AND SANITARY SEWER PIPES ARE DRAWN GRAPHICALLY ON THIS SURVEYAND SHOULD BE CONSIDERED APPROXIMATE. UNDERGROUND STORM AND SANITARY PIPES SHOULD BEVERIFIED INDEPENDENTLY AS TO THEIR LOCATION, SIZE AND TYPE BY THE CONTRACTOR OR DESIGNCONSULTANT PRIOR TO CONSTRUCTION.
10. THIS SURVEY IS PREPARED TO UNITED STATES STANDARD (U.S.S.), OTHER DISTANCES SHOWN ARE INPHILADELPHIA DISTRICT STANDARD AND ARE MARKED (P.D.S.).
11. ENCROACHMENTS AND VAULTS, IF ANY, BELOW SURFACE NOT SHOWN HEREON.
12. THE CONVERSION FROM INCHES TO THE MORE PRECISE DECIMAL EXPRESSION MAY RESULT IN MINORCHANGES IN THE SECOND AND THIRD DECIMAL PLACES, THESE ARE NOT ERRORS OR OVERSIGHTS BUTMORE PRECISE VALUES.
13. ATTENTION IS CALLED TO THE ZONING REQUIREMENTS IN THE PHILADELPHIA CODE AS AMENDED.
14. PLAN IS MADE PER INSTRUCTION OF LLC CALLOWHILL LLC.
15. BUILDING DIMENSIONS SHOWN HEREON ARE MEASURED AT GROUND LEVEL OF BUILDING EXTERIOR.
16. THERE WERE NO OBSERVED BUILDINGS ON THE SUBJECT PROPERTY.
EXHIBIT "A" - LEGAL DESCRIPTION
PREMISIES 'A' - NOT SURVEYED
PREMISES 'B'
ALL THAT CERTAIN LOT OR PIECE OF GROUND WITH THE BUILDINGS AND IMPROVEMENTS THEREON ERECTED.
SITUATE ON THE SOUTH SIDE OF CALLOWHILL STREET AT THE DISTANCE OF FORTY-EIGHT FEET WESTWARD FROM THE WEST SIDE OF13TH STREET IN THE FIFTH (FORMERLY PART OF THE FOURTEENTH) WARD OF THE CITY OF PHILADELPHIA.
CONTAINING IN FRONT OR BREADTH ON THE SAID CALLOWHILL STREET THIRTY-TWO FEET AND EXTENDING OF THAT WIDTH IN LENGTHOR DEPTH SOUTHWARD SIXTY-SEVEN FEET. SAME ALSO BEING DESCRIBED AS SIXTEEN FEET BY SIXTY-SEVEN FEET AND SIXTEEN FEETBY SEVENTY FEET.
ALSO, ALL THOSE TWO CERTAIN LOTS OR PIECES OF GROUND WITH THE BUILDINGS AND IMPROVEMENTS THEREON ERECTED.
SITUATE ON THE SOUTH SIDE OF CALLOWHILL STREET (NOS. 1310 AND 1312) IN THE FIFTH (FORMERLY PART OF THE FOURTEENTH)WARD OF THE CITY OF PHILADELPHIA.
ONE THEREOF AT THE DISTANCE OF EIGHTY FEET WESTWARD FROM THE WEST SIDE OF 13TH STREET, CONTAINING IN FRONT ON SAIDCALLOWHILL STREET EIGHTEEN FEET AND EXTENDING SOUTHWARD OF THE SAME WIDTH AND AT RIGHT ANGLES TO SAID CALLOWHILLSTREET ONE HUNDRED AND FORTY FEET TO CARLTON STREET, AND THE OTHER THEREOF AT THE DISTANCE OF NINETY-EIGHT FEETWESTWARD FROM THE WEST SIDE OF SAID 13TH STREET, CONTAINING IN FRONT ON SAID CALLOWHILL STREET SEVENTEEN FEET SIXINCHES AND EXTENDING SOUTHWARD OF THE SAME WIDTH AND AT RIGHT ANGLES TO SAID CALLOWHILL STREET ONE HUNDRED ANDFORTY FEET TO CARLTON STREET.
AND ALSO, ALL THAT CERTAIN LOT OR PIECE OF GROUND WITH THE BUILDINGS AND IMPROVEMENTS THEREON ERECTED.
SITUATE IN THE FIFTH (FORMERLY PART OF THE FOURTEENTH) WARD OF THE CITY OF PHILADELPHIA ON THE SOUTH SIDE OFCALLOWHILL STREET (NO. 1314) AT THE DISTANCE OF ONE HUNDRED AND FIFTEEN FEET SIX INCHES WESTWARD FROM THE WEST SIDEOF 13TH STREET; CONTAINING IN FRONT OR BREADTH ON SAID CALLOWHILL STREET SEVENTEEN FEET SIX INCHES AND EXTENDINGSOUTHWARD OF THAT WIDTH AND AT RIGHT ANGLES TO CALLOWHILL STREET ONE HUNDRED AND FORTY FEET TO CARLTON STREET.
TOGETHER BEING ASSESSED AS 1306-14 CALLOWHILL STREET.
BEING PARCEL #88-2-3401-00.
PREMISES 'C'
ALL THAT CERTAIN LOT OR PIECE OF GROUND, SITUATED IN THE 14TH WARD OF THE CITY OF PHILADELPHIA.
BEGINNING ON THE SOUTH SIDE OF CALLOWHILL STREET AT THE DISTANCE OF 133 FEET WESTWARD FROM THE WEST SIDE OF 13TH
STREET; THENCE RUNNING SOUTH AT RIGHT ANGLES WITH CALLOWHILL STREET 140 FEET TO CARLTON STREET; THENCE RUNNINGWESTWARD ALONG SAID CARLTON STREET 26 FEET 3 INCHES; THENCE RUNNING NORTH AT RIGHT ANGLES WITH THE SAID CALLOWHILLSTREET 70 FEET; THENCE EASTWARD PARALLEL WITH SAID CALLOWHILL STREET 8 FEET 9 INCHES; THENCE NORTH AT RIGHT ANGLESWITH SAID CALLOWHILL STREET 70 FEET TO CALLOWHILL STREET; THENCE EASTWARD ALONG SAID CALLOWHILL STREET 17 FEET 6INCHES TO THE BEGINNING.
ALSO ALL THAT CERTAIN LOT OR PIECE OF GROUND SITUATED ON THE SOUTH SIDE OF CALLOWHILL STREET IN THE 14TH WARD OF THECITY OF PHILADELPHIA.
BEGINNING AT THE DISTANCE OF 150 FEET 6 INCHES WESTWARD FROM THE WEST SIDE OF 13TH STREET; THENCE RUNNING WESTWARDALONG THE SAID CALLOWHILL STREET 35 FEET; THENCE SOUTHWARD AT RIGHT ANGLES WITH THE SAID CALLOWHILL STREET 140 FEETTO AN 18 FEET WIDE ALLEY CALLED CARLTON STREET; THENCE EASTWARD ALONG THE SAID CARLTON STREET 26 FEET 3 INCHES;THENCE NORTHWARD AT RIGHT ANGLES WITH SAID CALLOWHILL STREET 70 FEET; THENCE EASTWARD PARALLEL WITH SAIDCALLOWHILL STREET 8 FEET 9 INCHES; THENCE NORTHWARD AT RIGHT ANGLES WITH SAID CALLOWHILL STREET 70 FEET TOCALLOWHILL STREET AFORESAID AND PLACE OF BEGINNING.
BEING KNOWN AS 1316-20 CALLOWHILL STREET.
BEING PARCEL #88-2-8558-00.
PREMISES 'D'
ALL THAT CERTAIN LOT OR PIECE OF GROUND WITH THE BUILDINGS AND IMPROVEMENTS THEREON ERECTED.
SITUATE ON THE SOUTH SIDE OF CALLOWHILL STREET AT THE DISTANCE OF 220 FEET MEASURED EASTWARD FROM THE EAST SIDE OFBROAD STREET IN THE 5TH (FORMERLY PART OF THE 14TH) WARD OF THE CITY OF PHILADELPHIA.
CONTAINING IN FRONT OR BREADTH ON THE SAID CALLOWHILL STREET 122 FEET, 6 INCHES AND EXTENDING THENCE SOUTH BETWEENPARALLEL LINES WITH BROAD STREET IN LENGTH OR DEPTH 140 FEET TO CARLTON STREET.
BEING KNOWN AS 1322-34 CALLOWHILL STREET.
BEING PARCEL #88-2-8559-00.
WINDSTREAM PA, INC.CROWN CASTLE
AT & TCOMCAST CABLEVISION
PECOLEVEL 3
MCIPHILADELPHIA CITY WATER DEPT
ZAYO BANDWIDTHPHILADELPHIA DEPT OF STREETS
PHILADELPHIA GAS WORKSRCN CABLE(FORMERLY C-TECH)
SEPTASUNGARD RECOVERY SERVICES
VEOLIA ENERGY PHILADELPHIA, INC (TRIGEN)VERIZON
866-255-8356215-951-2700800-222-0400215-961-3800610-943-5522720-888-0165800-888-0800215-685-6300610-774-5151215-686-5503215-978-3000484-461-6020215-580-7852215-413-1875215-875-6900215-963-6000
PHONE NUMBER
THIS IS TO CERTIFY THAT THIS MAP OR PLAT AND THE SURVEY ON WHICH IT WAS BASED WEREMADE IN ACCORDANCE WITH THE "2016 MINIMUM STANDARD DETAIL REQUIREMENTS FORALTA/NSPS LAND TITLE SURVEYS", JOINTLY ESTABLISHED AND ADOPTED BY ALTA AND NSPS,AND INCLUDES ITEMS 2, 3, 4, 5, 8, 9, 11, & 13 OF TABLE A THEREOF. THE FIELD WORK WASCOMPLETED ON 12-04-2019.
12-23-2019
THIS SURVEY IS CERTIFIED TO:
FIDELITY NATIONAL TITLE INSURANCE COMPANYLLC CALLOWHILL LLC, A PENNSYLVANIA LIMITED LIABILITY COMPANY
SITE
TITLE REPORT EXCEPTION
APPROX. LOC. UNDERGROUND WATER LINE
PHILADELPHIA DISTRICT STANDARD
UNITED STATES STANDARD
LLCP Callowhill LLC Multi-Family Development
11
Zoning Plan
CARLTON STREET(A.K.A. BLOOM ALLEY)
(VARIABLE WIDTH R.O.W.) (LEGALLY OPEN)(5.8' - 6.3' - 5.8') & (5.8' - 14.4' - 5') (ON CITY PLAN)
(5.4' - 6.4' - 5.9') & (4.8' - 14.3' - 6') (ACTUAL)
CALLOWHILL STREET(50' R.O.W.) (LEGALLY OPEN)
(11'-31'-8') (ON CITY PLAN)(10.9'-31.2'-8') (ACTUAL)
BR
OA
D S
TR
EE
T(1
13' R
.O.W
) (LE
GAL
LY O
PEN
)(2
2'-6
9'-2
2') (
ON
CIT
Y PL
AN)
13T
H S
TR
EE
T(5
0' R
.O.W
.) (L
EGAL
LY O
PEN
)(1
2' -2
6'-1
2') (
ON
CIT
Y PL
AN)
260'
62'
33.5'
78'
140'
PROPOSED CONCRETECURB (TYP.)
PROP. 24'CURB CUT20.4' 192' 73'
PROPOSED MULTI-STORYMIXED-USE BUILDING(APPROX. 33,787 SF)
(55 PARKING SPACES)
9
16
16
10 318
'18
'
PROPOSED BUILDINGOVERHANG
(12' VERTICAL CLEARANCE)
PROP. 12'CURB CUT
4' PR
OP. F
URNI
SHIN
G ZO
NE
7.3' P
ROP.
WAL
KING
ZON
E
5' PR
OP. W
ALKI
NG Z
ONE
0.9' P
ROP.
FUR
NISH
ING
ZONE
226.5'
1
.8'
.4'
.3'
.6'
.3'
4.8'4.8
'
1.7'
1.3'
18'
24'
24'
24'
18'
.3'
4' 4'
9'9'
18'
45' 40
'
10'
7'
15'
7'
15'
7'
15'
9'9'9'9'9'9'9'9'9'9'9'9' 9'9'9' 8.5'8.5'
9' 9' 9' 9' 9' 9' 9' 9' 9' 9' 8.5'9' 8.5'
9'9'
9'9'
9'9'
9'9'
8.5'
30.7' 28'
PROPOSED BUILDINGOVERHANG
(13' VERTICAL CLEARANCE)
3.7'
3.7'
PROPOSED "U"BIKE RACK
ZONING
11"= 20'
0 2051020
REVISIONS
REV DATE COMMENTDRAWN BY
CHECKED BY
1
2
3
4
5
REVISION 5 -
3/27/2020 PER L&I COMMENTS NOLMJK
4/6/2020 PER L&I COMMENTS MJK
4/21/2020 PER CDR COMMENTS MJK
4/27/2020 PER STREETSCOMMENTS
MJK
6/10/2020 PER RCO COMMENTS MJK.
6/10/2020
DISC
LAIM
ER
PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:
PROJECT:
FOR
R:\1
9\P
P19
3141
\DR
AW
ING
S\P
LA
N S
ET
S\B
AS
E\R
EV
-6 (Z
ON
ING
RE
V-5
)\P
P19
3141
BA
SE
-6--
--->
LA
YO
UT
: Z1-
ZO
NIN
G
MK
THIS DRAWING IS INTENDED FOR MUNICIPAL AND/ORAGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A
CONSTRUCTION DOCUMENT UNLESS INDICATEDOTHERWISE.
SHEET NUMBER:
SHEET TITLE:
PP193141KASMJK
03/11/2020PP193141BASE-6
ZONING PLANS
LLCP CALLOWHILL,LLC
LLCP CALLOWHILL, LLCAPARTMENT PROJECT
1322-34 CALLOWHILL STREET5TH WARD
CITY AND COUNTY OFPHILADELPHIA, PA
PENNSYLVANIAYOU MUST CALL 811 BEFORE ANY EXCAVATIONWHETHER IT'S ON PRIVATE OR PUBLIC LAND.
1-800-242-1776www.pa1call.org
FOR CONCEPTPURPOSES ONLY
1515 MARKET STREET, SUITE 920PHILADELPHIA, PA 19102
Phone: (267) 402-3400Fax: (267) 402-3401
www.BohlerEngineering.com
TM
THE
INFO
RMAT
ION,
DES
IGN
AND
CONT
ENT
OF T
HIS
PLAN
ARE
PRO
PRIE
TARY
AND
SHA
LL N
OT B
E CO
PIED
OR
USED
FOR
ANY
PUR
POSE
WIT
HOUT
PRI
OR W
RITT
ENAU
THOR
IZAT
ION
FROM
BOH
LER.
ONL
Y AP
PROV
ED, S
IGNE
D AN
D SE
ALED
PLA
NS S
HALL
BE
UTILI
ZED
FOR
CONS
TRUC
TION
PUR
POSE
S©
SIT
E C
IVIL
AN
D C
ON
SU
LT
ING
EN
GIN
EE
RIN
GL
AN
D S
UR
VE
YIN
GP
RO
GR
AM
MA
NA
GE
ME
NT
LA
ND
SC
AP
E A
RC
HIT
EC
TU
RE
SU
ST
AIN
AB
LE
DE
SIG
NP
ER
MIT
TIN
G S
ER
VIC
ES
TR
AN
SP
OR
TA
TIO
N S
ER
VIC
ES
BOH
LER
SITE
LLCP Callowhill LLC Multi-Family Development
12
Vehicular Circulation Plan
CARLTON STREET(A.K.A. BLOOM ALLEY)
(VARIABLE WIDTH R.O.W.) (LEGALLY OPEN)(5.8' - 6.3' - 5.8') & (5.8' - 14.4' - 5') (ON CITY PLAN)
(5.4' - 6.4' - 5.9') & (4.8' - 14.3' - 6') (ACTUAL)
CALLOWHILL STREET(50' R.O.W.) (LEGALLY OPEN)
(11'-31'-8') (ON CITY PLAN)(10.9'-31.2'-8') (ACTUAL)
BR
OA
D S
TR
EE
T(1
13' R
.O.W
) (LE
GAL
LY O
PEN
)(2
2'-6
9'-2
2') (
ON
CIT
Y PL
AN)
13T
H S
TR
EE
T(5
0' R
.O.W
.) (L
EGAL
LY O
PEN
)(1
2' -2
6'-1
2') (
ON
CIT
Y PL
AN)
9
16
16
10 31
SITE
VEHICLECIRCULATION
PLAN
11"= 20'
0 2051020
ORG. DATE -
REVISIONS
REV DATE COMMENTDRAWN BY
CHECKED BY
3/11/2020
DISC
LAIM
ER
PROJECT No.:DRAWN BY:CHECKED BY:DATE:CAD I.D.:
PROJECT:
FOR
R:\1
9\P
P19
3141
\DR
AW
ING
S\P
LA
N S
ET
S\B
AS
E\R
EV
-5 (Z
ON
ING
RE
V-4
)\P
P19
3141
BA
SE
-5--
--->
LA
YO
UT
: C1-
CA
R C
IRC
UL
AT
ION
MK
THIS DRAWING IS INTENDED FOR MUNICIPAL AND/ORAGENCY REVIEW AND APPROVAL. IT IS NOT INTENDED AS A
CONSTRUCTION DOCUMENT UNLESS INDICATEDOTHERWISE.
SHEET NUMBER:
SHEET TITLE:
PENNSYLVANIAYOU MUST CALL 811 BEFORE ANY EXCAVATIONWHETHER IT'S ON PRIVATE OR PUBLIC LAND.
1-800-242-1776www.pa1call.org
FOR CONCEPTPURPOSES ONLY
1515 MARKET STREET, SUITE 920PHILADELPHIA, PA 19102
Phone: (267) 402-3400Fax: (267) 402-3401
www.BohlerEngineering.com
TM
THE
INFO
RMAT
ION,
DES
IGN
AND
CONT
ENT
OF T
HIS
PLAN
ARE
PRO
PRIE
TARY
AND
SHA
LL N
OT B
E CO
PIED
OR
USED
FOR
ANY
PUR
POSE
WIT
HOUT
PRI
OR W
RITT
ENAU
THOR
IZAT
ION
FROM
BOH
LER.
ONL
Y AP
PROV
ED, S
IGNE
D AN
D SE
ALED
PLA
NS S
HALL
BE
UTILI
ZED
FOR
CONS
TRUC
TION
PUR
POSE
S©
SIT
E C
IVIL
AN
D C
ON
SU
LT
ING
EN
GIN
EE
RIN
GL
AN
D S
UR
VE
YIN
GP
RO
GR
AM
MA
NA
GE
ME
NT
LA
ND
SC
AP
E A
RC
HIT
EC
TU
RE
SU
ST
AIN
AB
LE
DE
SIG
NP
ER
MIT
TIN
G S
ER
VIC
ES
TR
AN
SP
OR
TA
TIO
N S
ER
VIC
ES
BOH
LER
PP193141NOLMJK
3/11/2020PP193141-CAR CIRCULATION-TB-0
CAR CIRCULATIONPLAN
LLCP CALLOWHILL,LLC
LLCP CALLOWHILL, LLCAPARTMENT PROJECT
1322-34 CALLOWHILL STREET5TH WARD
CITY AND COUNTY OFPHILADELPHIA, PA
LLCP Callowhill LLC Multi-Family Development
13
� � � � � � � � � � � � �
�� �� ��� � � � � � � � � �
Ground Floor Plan
!"#$%&'
#()"%*+"%&,#(-%.(&)%"*,
*/001
0%$(,-)/#"'(
*/".%&'
-!"2(
3&.(#'#/3&.,
-)/#+4")(#,+"&"'(+(&)
LLCP Callowhill LLC Multi-Family Development
14
� � � � � � � � � � � � �� � � � � �
Ground Floor Streetscape
!"#$%&'
#()"%*+"%&,#(-%.(&)%"*,
*/001
0%$(,-)/#"'(
*/".%&'
-!"2(
3&.(#'#/3&.,
-)/#+4")(#,+"&"'(+(&)
BIKE RACKSEXTERIOR LIGHTING
BOX PLANTERS
1
2 3
31 1 12 2 2 2 2 2 2
!"#$%&'((&)#*$$#)+',$&$($-$!#)&)."/!&0"*&1$)23!&+"!+$,#&"!(45&&02!'(&',,*"6'(&#"&7$&,*"621$1&74&,.2('1$(,.2'&)#*$$#)&1$,'*#-$!#5
)#*$$#)+',$&$($-$!#)89:;<=&>;?&+;=@ABC&1A9DE=&;=FGHI
I
LLCP Callowhill LLC Multi-Family Development
15
Second Floor Plan
CALLOWHILL STREET
13TH STR
EET
CARLTON STREET
21’-0”TYP
AMENITY SPACE FITNESS
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL
RESIDENTIALPRIVATE PATIOS
PRIVATE PATIOS
COURTYARDDECK
LLCP Callowhill LLC Multi-Family Development
16
Third - Seventh Floor Plans
CALLOWHILL STREET
13TH STR
EET
CARLTON STREET
RESIDENTIAL
RESIDENTIAL
RESIDENTIAL PRIVATEPATIOSBELOW
PRIVATEPATIOSBELOW
COURTYARD BELOW
21’-0”TYP
LLCP Callowhill LLC Multi-Family Development
17
Enlarged Landscape Plans
fringetreeChionanthus virginicus Hamamelis x intermedia
‘Arnold’s Promise’ witchhazel
Ilex verticillata(summer)winterberry holly
redtwig dogwoodCornus sericea(summer) Sarcocca hookeriana var. Humilis
sweet box
COURTYARD PLANT MATERIAL
Buxus sempervirens ‘Suffruticosa’dwarf English boxwood
Ilex verticillata (winter)winterberry holly redtwig dogwood
Cornus sericea (winter)
may night salviaSalvia x sylvestris ‘May Night’ Deschampsia cespitosa
tufted hair grass creek sedgeCarex amphibola Aronia melanocarpa ‘Lowscape Hedger’
Lowscape Hedger black chokeberry
ENLARGED COURTYARD DECK ENLARGED PRIVATE PATIO,TYPICAL
A
D
D
A
D
A
C
TREES
Typical Planter
Typical Planter
Paver
B
D
C
D
PERENNIALS PAVER
SHRUBS
SHRUBS
B
B
DC
PRIVATE PATIO
PRIVATE PATIO
PRIVATE PATIO
LLCP Callowhill LLC Multi-Family Development
18
�����������
�����������
�����������(30’-0” x 16’-0”)
���������� TYPICAL RAISED PLANTER DETAIL
BUFFER ZONE(8’ WIDE, TYPICAL)
COURTYARD RESIDENTIAL UNIT
�����������(8’-0” W, TYPICAL)
��
ENLARGED COURTYARD DECK
fringetreeChionanthus virginicus
Enlarged Landscape PlanGreen Space Designations
Hamamelis x intermedia‘Arnold’s Promise’ witchhazel
REDS & SON
GARAGEENTRY
GE4
�����������������������������
LLCP Callowhill LLC Multi-Family Development
19
Brick Veneer
Cast Stone Veneer
Smooth Face CMU Veneer
Fiber Cement Panel System
Fiber Cement Lap Siding
Metal Panel
Curtainwall
Storefront
Casement Window
Not Used
Prefabricated Metal Awning
Overhead Door
Metal Mesh Screening
Balcony Privacy Screen
Key
1
2
3
4
5
6
7
8
9
10
11
13
12
14
����������
�������
��
North Elevation (Callowhill Street)
1
5
4
2
12
9
12 12
9 4 5
8 6 7
9 9
1111
CJ
CJ
14
����������������������������������� � ���������
LLCP Callowhill LLC Multi-Family Development
20
Brick Veneer
Cast Stone Veneer
Smooth Face CMU Veneer
Fiber Cement Panel System
Fiber Cement Lap Siding
Metal Panel
Curtainwall
Storefront
Casement Window
Not Used
Prefabricated Metal Awning
Overhead Door
Metal Mesh Screening
Balcony Privacy Screen
Key
1
2
3
4
5
6
7
8
9
10
11
13
12
14
����������
�������
��
South Elevation (Carlton Street)
5
3
5
5 5
13
9
8
5
9 9
14
�������������������������������
����������������� ��������������
!"#"$%&'"$($)%'*+,"-!./0"&/122/3 4"#"5$&'"$($)%'*+,"-678692:/";6:<=21">?@A7@:B3
12
LLCP Callowhill LLC Multi-Family Development
21
Brick Veneer
Cast Stone Veneer
Smooth Face CMU Veneer
Fiber Cement Panel System
Fiber Cement Lap Siding
Metal Panel
Curtainwall
Storefront
Casement Window
Not Used
Prefabricated Metal Awning
Overhead Door
Metal Mesh Screening
Balcony Privacy Screen
Key
1
2
3
4
5
6
7
8
9
10
11
13
12
14
����������
�������
��
East / West Elevation
5
5
9
5
3
9
5
5
141
5
LLCP Callowhill LLC Multi-Family Development
22
Brick Veneer
Cast Stone Veneer
Smooth Face CMU Veneer
Fiber Cement Panel System
Fiber Cement Lap Siding
Metal Panel
Curtainwall
Storefront
Casement Window
Not Used
Prefabricated Metal Awning
Overhead Door
Metal Mesh Screening
Balcony Privacy Screen
Key
1
2
3
4
5
6
7
8
9
10
11
13
12
14
����������
�������
��
Partial Courtyard Elevations
5
9 5
5
5
9
5 5
LLCP Callowhill LLC Multi-Family Development
23
Building MaterialsExterior materials will compliment the industrial urban aesthetic of the surrounding area. Th e following design elements have been introduced to articulate the overall massing:
A rich combination of aged-red brick, cast stone, and smooth face concrete masonry units will compliment the adjacent buildings and recall the site’s industrial historyA two-story curtainwall and metal panel main entry will provide a sense of buidling identity and site arrivalLarge expanses of retail space storefront will connect the urban fabric and provide ample daylighting to interior spacesPrefabricated metal canopies will provide shelter at both the residential and retail building entrancesTh e integration of brick, fi ber cement panel, and fi ber cement lap siding at the uppper fl oors will help break down the perceived height of the buildingPunched openings infi lled with various arrangements of residential casement and fi xed windows will provide natural light into residential unitsMetal mesh panels will screen the parking garage from the adjacent buildings
Cast Stone Veneer Examples
Brick Veneer Example
Fiber Cement Panel System Example Prefabricated Metal Awning Example
Aluminum Railing Example Fiber Cement Lap Siding Example Metal Mesh Garage Screening Example
Smooth Face CMU Exmaple
Metal Panel Example
•
•
•
••
•
•
Note that the specifi c architectural design elements for this building will continue to be developed as the project evolves.
Building Materials
LLCP Callowhill LLC Multi-Family Development
24
Site Section (North/South)
�����������������������������
������������������ ���������
�������
�����������
�����������
�����������
�����������
�����������
�������
����������������������������
�������������� ������ ����������
LLCP Callowhill LLC Multi-Family Development
25
Site Section (East/West)
CJ
CJ
14
�����������
�����������
�����������
�����������
�����������
�����������
�����������
�����������
�����������
�����������
�����������
�����������
�����������
�������
����������������������������
������������������������ �
����������������������������
LLCP Callowhill LLC Multi-Family Development
26
3D Massing
FROM NORTHWEST FROM SOUTHEAST
FROM NORTHEAST
LLCP Callowhill LLC Multi-Family Development
27
Exterior Rendering
LLCP Callowhill LLC Multi-Family Development
28
Exterior Rendering
LLCP Callowhill LLC Multi-Family Development
29
Civic Design Review Sustainable Design Checklist
· Reuse of existing building stock· Incorporation of existing on-site natural habitats and landscape elements· Inclusion of high-performing stormwater control· Site and building massing to maximize daylight and reduce shading on adjacent sites· Reduction of energy use and the production of greenhouse gases· Promotion of reasonable access to transportation alternatives
Categories Benchmark Does project meet benchmark? If yes, please explain how. If no, please explain why not.
(1) Access to Quality Transit
Locate a functional entry of the project within a ¼-mile (400-meter) walking distance of existing or planned bus, streetcar, or rideshare stops, bus rapid transit stops, light or heavy rail stations.
Yes, the main entry of the project is located within 1/4 mile of an Indego Bike Share Station, the Broad Street Subway, and multiple bus stops with access to over a dozen bus routes.
(2) Reduced Parking Footprint
All new parking areas will be in the rear yard of the property or under the building, and unenclosed or uncovered parking areas are 40% or less of the site area.
Yes, all new parking is located under the building at ground level. Although accessed from Callowhill Street, the parking garage does not have a large visible presence along the front of the property as it is situated towards the rear of the property.
(3) Green Vehicles
Designate 5% of all parking spaces used by the project as preferred parking for green vehicles or car share vehicles.Clearly identify and enforce for sole use by car share or green vehicles, which include plug-in electric vehicles and alternative fuel vehicles.
No, the project does not designate preferred parking for green vehicles or car share vehicles.
(4) Railway Setbacks (Excluding frontages facing trolleys/light rail or enclosed subsurface rail lines or subways)
To foster safety and maintain a quality of life protected from excessive noise and vibration, residential development with railway frontages should be setback from rail lines and the building’s exterior envelope, including windows, should reduce exterior sound transmission to 60dBA. (If setback used, specify distance)i
Not applicable. The project is not located near active rail lines and is also locatred more than 400 ft away from the Vine Street Expressway.
(5) Bike Share Station Incorporate a bike share station in coordination with and conformance to the standards of Philadelphia Bike Share.
No, the project itself does not incorporate a Bike Share Station because there is an existing Indego Bike Share Station less than a block away. The project does provide Class 1A covered, protected bicycle storage for resident use only.
Location and Transportation
Sustainable design represents important city-wide concerns about environmental conservation and energy use. Development teams should try to integrate elements that meet many goals, including:
The Sustainable Design Checklist asks for responses to specific benchmarks. These metrics go above and beyond the minimum requirements in the Zoning and Building codes. All benchmarks are based on adaptions from Leadership in Energy and Environmental Design (LEED) v4 unless otherwise noted.
(6) Outdoor Water UseMaintain on-site vegetation without irrigation. OR, Reduce of watering requirements at least 50% from the calculated baseline for the site's peak watering month.
No. Although there is no existing or proposed vegetation at ground level, irrigation will be required within planters at the new elevated courtyard deck.
(7) Pervious Site Surfaces
Provides vegetated and/or pervious open space that is 30% or greater of the site's Open Area, as defined by the zoning code. Vegetated and/or green roofs can be included in this calculation.
No. The project is a zero-lot line building that does not contain a vegetated or green roof.
(8) Rainwater Management
Conform to the stormwater requirements of the Philadelphia Water Department(PWD) and either: A) Develop a green street and donate it to PWD, designed and constructed in accordance with the PWD Green Streets Design Manual, OR B) Manage additional runoff from adjacent streets on the development site, designed and constructed in accordance with specifications of the PWD Stormwater Management Regulations
No, the project will not be providing any additional rainwater management provisions as noted.
(9) Heat Island Reduction (excluding roofs)
Reduce the heat island effect through either of the following strategies for 50% or more of all on-site hardscapes:A) Hardscapes that have a high reflectance, an SRI>29.B) Shading by trees, structures, or solar panels.
Yes, the project will provide 50% or more of hardscapes with and SRI greater than 29.
Sustainable Sites
Water Efficiency
(10) Energy Commissioning and Energy Performance - Adherence to the New Building Code
PCPC notes that as of April 1, 2019 new energy conservation standards are required in the Philadelphia Building Code, based on recent updates of the International Energy Conservation Code (IECC) and the option to use ASHRAE 90.01-2016. PCPC staff asks the applicant to state which path they are taking for compliance, including their choice of code and any options being pursued under the 2018 IECC.ii
The project will be complying with the requirements of 2018 IECC.
(11) Energy Commissioning and Energy Performance - Going beyond the code
Will the project pursue energy performance measures beyond what is required in the Philadelphia code by meeting any of these benchmarks? ii
- Reduce energy consumption by achieving 10% energy savings or more from an established baseline using ASHRAE standard 90.1-2016 (LEED v4.1 metric). - Achieve certification in Energy Star for Multifamily New Construction (MFNC).- Achieve Passive House Certification
The project will not pursue energy performance measures beyond what is required by the Philadelphia Energy Code. The HVAC systems will comply with all applicable energy codes, but by the nature of the system they will not exceed the ASHRAE established baseline by 10%.
(12) Indoor Air Quality and Transportation
Any sites within 1000 feet of an interstate highway, state highway, or freeway will provide air filters for all regularly occupied spaces that have a Minimum Efficiency Reporting Value (MERV) of 13. Filters shall be installed prior to occupancy.iv
Yes, the project is within 1000 ft of a freeway, thus all air filtration filtering outside have will have a minimum MERV value of 13.
(13) On-Site Renewable EnergyProduce renewable energy on-site that will provide at least 3% of the project's anticipated energy usage.
No, the project will not incorporate any on-site renewable energy.
(14) Innovation
Any other sustainable measures that could positively impact the public realm.
The project site is closely adjacent to Philadelphia's Rail Park, a vision that will transform three miles of unused rail lines into elevated public open space. Phase 1, the Viaduct, is completed and accessible via a staircase between 11th and 12th and Callowhill which is located less than 100 meteres from our main building entry.
iii LEED 4.1, Optimize Energy Performance in LEED v4.1For Energy Star: www.Energystar.gov
For Passive House, see www.phius.org
iv Section 99.04.504.6 "Filters" of the City of Los Angeles Municipal Code, from a 2016 Los Angeles Ordinance requiring enhanced air filters in homes near freeways
https://www.phila.gov/li/Documents/What%20Code%20Do%20I%20Use.pdf
i Railway Association of Canada (RAC)'s “Guidelines for New Development in Proximity to Railway Operations. Exterior Sound transmission standard from LEED v4, BD+C, Acoustic Performance Credit.
ii Title 4 The Philadelphia Building Construction and Occupancy CodeSee also, “The Commercial Energy Code Compliance” information sheet: https://www.phila.gov/li/Documents/Commercial%20Energy%20Code%20Compliance%20Fact%20Shee t--Final.pdf
and the “What Code Do I Use” information sheet:
Energy and Atmosphere
Innovation
(8) Rainwater Management
Conform to the stormwater requirements of the Philadelphia Water Department(PWD) and either: A) Develop a green street and donate it to PWD, designed and constructed in accordance with the PWD Green Streets Design Manual, OR B) Manage additional runoff from adjacent streets on the development site, designed and constructed in accordance with specifications of the PWD Stormwater Management Regulations
No, the project will not be providing any additional rainwater management provisions as noted.
(9) Heat Island Reduction (excluding roofs)
Reduce the heat island effect through either of the following strategies for 50% or more of all on-site hardscapes:A) Hardscapes that have a high reflectance, an SRI>29.B) Shading by trees, structures, or solar panels.
Yes, the project will provide 50% or more of hardscapes with and SRI greater than 29.
Sustainable Design Checklist
30
COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission
3
GENERAL PROJECT INFORMATION 1. PROJECT NAME
Linden Lane Callowhill 2. DATE
03/10/2020 3. APPLICANT NAME
LLCP Callowhill, LLC 4. APPLICANT CONTACT INFORMATION
610-889-3600
5. PROJECT AREA: list precise street limits and scope The site is bound by two existing buildings to the East and West as well as Callowhill and Carlton Streets to the North and South respectively. The existing site consists of a parking lot that will be replaced by a multi-story mixed use building.
6. OWNER NAME LLCP Callowhill, LLC
7. OWNER CONTACT INFORMATION 610-889-3600
8. ENGINEER / ARCHITECT NAME Cornelius Brown (Bohler)
9. ENGINEER / ARCHITECT CONTACT INFORMATION 267-402-3400
10. STREETS: List the streets associated with the project. Complete Streets Types can be found at www.phila.gov/map under the “Complete Street Types” field. Complete Streets Types are also identified in Section 3 of the Handbook. Also available here: http://metadata.phila.gov/#home/datasetdetails/5543867320583086178c4f34/
STREET FROM TO COMPLETE STREET TYPE Callowhill St. Broad St. 13th St. Urban/Arterial Carlton St. Broad St. 13th St. Local/Other
11. Does the Existing Conditions site survey clearly identify the following existing conditions with dimensions? a. Parking and loading regulations in curb lanes adjacent to the site YES NO b. Street Furniture such as bus shelters, honor boxes, etc. YES NO N/A c. Street Direction YES NO d. Curb Cuts YES NO N/A e. Utilities, including tree grates, vault covers, manholes, junction
boxes, signs, lights, poles, etc. YES NO N/A
f. Building Extensions into the sidewalk, such as stairs and stoops YES NO N/A
APPLICANT: General Project Information Additional Explanation / Comments:
DEPARTMENTAL REVIEW: General Project Information
4
PEDESTRIAN COMPONENT (Handbook Section 4.3) 12. SIDEWALK: list Sidewalk widths for each street frontage. Required Sidewalk widths are listed in Section 4.3 of the
Handbook. STREET FRONTAGE TYPICAL SIDEWALK WIDTH
(BUILDING LINE TO CURB) Required / Existing / Proposed
CITY PLAN SIDEWALK WIDTH Existing / Proposed
Callowhill St. 10’ / 10.9’ / 10.9’ 11’ / 10.9’ Carlton St. 10’ / 5.9’ / 5.9’ 5.8 / 5.9’ / / / / / /
13. WALKING ZONE: list Walking Zone widths for each street frontage. The Walking Zone is defined in Section 4.3 of the Handbook, including required widths.
STREET FRONTAGE WALKING ZONE Required / Existing / Proposed
Callowhill St. 6’ / 10.9’ / 7.3’ Carlton St. 5’ / 5.9’ / 5.0’ / / / /
14. VEHICULAR INTRUSIONS: list Vehicular Intrusions into the sidewalk. Examples include but are not limited to; driveways, lay-by lanes, etc. Driveways and lay-by lanes are addressed in sections 4.8.1 and 4.6.3, respectively, of the Handbook. EXISTING VEHICULAR INTRUSIONS
INTRUSION TYPE INTRUSION WIDTH PLACEMENT Driveway 26.7’ Callowhill Street Driveway 31.5’ Callowhill Street
PROPOSED VEHICULAR INTRUSIONS INTRUSION TYPE INTRUSION WIDTH PLACEMENT Driveway 24’ Callowhill Street Driveway 12’ Callowhill Street
31
Philadelphia City Planning Commission
5
PEDESTRIAN COMPONENT (continued) DEPARTMENTAL
APPROVAL
15. When considering the overall design, does it create or enhance a pedestrian environment that provides safe and comfortable access for all pedestrians at all times of the day?
YES NO YES NO
APPLICANT: Pedestrian Component Additional Explanation / Comments:
DEPARTMENTAL REVIEW: Pedestrian Component Reviewer Comments:
COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission
BUILDING & FURNISHING COMPONENT (Handbook Section 4.4) 16. BUILDING ZONE: list the MAXIMUM, existing and proposed Building Zone width on each street frontage. The Building
Zone is defined as the area of the sidewalk immediately adjacent to the building face, wall, or fence marking the property line, or a lawn in lower density residential neighborhoods. The Building Zone is further defined in section 4.4.1 of the Handbook.
STREET FRONTAGE MAXIMUM BUILDING ZONE WIDTH Existing / Proposed
Callowhill St. 0’ / 0’ Carlton St. 0’ / 0’ / /
17. FURNISHING ZONE: list the MINIMUM, recommended, existing, and proposed Furnishing Zone widths on each street frontage. The Furnishing Zone is further defined in section 4.4.2 of the Handbook.
STREET FRONTAGE MINIMUM FURNISHING ZONE WIDTH Recommended / Existing / Proposed
Callowhill St. 4’ / 5.3’ / 4.0’ Carlton St. 4’ / 0’ / 0.9’ / / / /
18. Identify proposed “high priority” building and furnishing zone design treatments that are incorporated into the design plan, where width permits (see Handbook Table 1). Are the following treatments identified and dimensioned on the plan?
DEPARTMENTAL APPROVAL
▪ Bicycle Parking YES NO N/A YES NO ▪ Lighting YES NO N/A YES NO ▪ Benches YES NO N/A YES NO ▪ Street Trees YES NO N/A YES NO ▪ Street Furniture YES NO N/A YES NO
19. Does the design avoid tripping hazards? YES NO N/A YES NO
20. Does the design avoid pinch points? Pinch points are locations where the Walking Zone width is less than the required width identified in item 13, or requires an exception
YES NO N/A YES NO
Philadelphia City Planning Commission
7
BUILDING & FURNISHING COMPONENT (continued)
APPLICANT: Building & Furnishing Component Additional Explanation / Comments: Street trees cannot be installed due to existing utility conflicts.
DEPARTMENTAL REVIEW: Building & Furnishing Component Reviewer Comments:
21. Do street trees and/or plants comply with street installation requirements (see sections 4.4.7 & 4.4.8)
YES NO N/A YES NO
22. Does the design maintain adequate visibility for all roadway users at intersections?
YES NO N/A YES NO
COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission
BICYCLE COMPONENT (Handbook Section 4.5) 23. List elements of the project that incorporate recommendations of the Pedestrian and Bicycle Plan, located online at
http://phila2035.org/wp-content/uploads/2012/06/bikePedfinal2.pdf Link is no longer valid.
24. List the existing and proposed number of bicycle parking spaces, on- and off-street. Bicycle parking requirements are provided in The Philadelphia Code, Section 14-804.
BUILDING / ADDRESS REQUIRED SPACES
ON-STREET Existing / Proposed
ON SIDEWALK Existing / Proposed
OFF-STREET Existing / Proposed
1300 Callowhill 61 Class 1A 0 / 0 0 / 0 0 / 61 Class 1A / / / / / / / / /
25. Identify proposed “high priority” bicycle design treatments (see Handbook Table 1) that are
incorporated into the design plan, where width permits. Are the following “High Priority” elements identified and dimensioned on the plan?
DEPARTMENTAL APPROVAL
▪ Conventional Bike Lane YES NO N/A YES NO ▪ Buffered Bike Lane YES NO N/A YES NO ▪ Bicycle-Friendly Street ▪ Indego Bicycle Share Station
YES NO N/A YES NO N/A
YES NO YES NO
26. Does the design provide bicycle connections to local bicycle, trail, and transit networks?
YES NO N/A YES NO
27. Does the design provide convenient bicycle connections to residences, work places, and other destinations?
YES NO N/A YES NO
APPLICANT: Bicycle Component Additional Explanation / Comments: Class 1A bicycle storage meeting the minimum required number of parking spaces is provided within the proposed parking garage. All bicycle storage will be accessible via a continuous route from the public Right-Of-Way.
DEPARTMENTAL REVIEW: Bicycle Component Reviewer Comments:
32
COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission
9
CURBSIDE MANAGEMENT COMPONENT (Handbook Section 4.6) DEPARTMENTAL
APPROVAL
28. Does the design limit conflict among transportation modes along the curb?
YES NO YES NO
29. Does the design connect transit stops to the surrounding pedestrian network and destinations?
YES NO N/A YES NO
30. Does the design provide a buffer between the roadway and pedestrian traffic?
YES NO N/A YES NO
31. How does the proposed plan affect the accessibility, visibility, connectivity, and/or attractiveness of public transit?
YES NO
APPLICANT: Curbside Management Component Additional Explanation / Comments: The proposed plan does not disrupt the accessibility or visibility to public transit. SEPTA bus stops are located within one block (both east/west) of the proposed project site. The proposed project enhances the connectivity and attractiveness of the public transit experience in the area by developing an existing surface parking lot into a more lively and attractive streetscape for pedestrians traveling to/from adjacent transit stops.
DEPARTMENTAL REVIEW: Curbside Management Component Reviewer Comments:
COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission
VEHICLE / CARTWAY COMPONENT (Handbook Section 4.7) 32. If lane changes are proposed, , identify existing and proposed lane widths and the design speed for each street
frontage; STREET FROM TO LANE WIDTHS
Existing / Proposed DESIGN SPEED
Callowhill St. Broad St. 13th St. 10’ / 10’ 25 mph Carlton St. Broad St. 13th St. 6.4’ / 6.4’ N/A / /
DEPARTMENTAL
APPROVAL
33. What is the maximum AASHTO design vehicle being accommodated by the design?
SU-30 YES NO
34. Will the project affect a historically certified street? An inventory of historic streets(1) is maintained by the Philadelphia Historical Commission.
YES NO YES NO
35. Will the public right-of-way be used for loading and unloading activities?
YES NO
36. Does the design maintain emergency vehicle access? YES NO YES NO
37. Where new streets are being developed, does the design connect and extend the street grid?
YES NO N/A YES NO
YES NO
10
/ /
DEPARTMENTAL
APPROVAL
33. What is the maximum AASHTO design vehicle being accommodated by the design?
SU-30 YES NO
34. Will the project affect a historically certified street? An inventory of historic streets(1) is maintained by the Philadelphia Historical Commission.
YES NO YES NO
35. Will the public right-of-way be used for loading and unloading activities?
YES NO
36. Does the design maintain emergency vehicle access? YES NO YES NO
37. Where new streets are being developed, does the design connect and extend the street grid?
YES NO N/A YES NO
38. Does the design support multiple alternative routes to and from destinations as well as within the site?
YES NO N/A YES NO
39. Overall, does the design balance vehicle mobility with the mobility and access of all other roadway users?
YES NO YES NO
APPLICANT: Vehicle / Cartway Component Additional Explanation / Comments:
DEPARTMENTAL REVIEW: Vehicle / Cartway Component Reviewer Comments:
(1) http://www.philadelphiastreets.com/images/uploads/documents/Historical_Street_Paving.pdf
YES NO
COMPLETE STREETS HANDBOOK CHECKLIST Philadelphia City Planning Commission
URBAN DESIGN COMPONENT (Handbook Section 4.8) DEPARTMENTAL
APPROVAL
40. Does the design incorporate windows, storefronts, and other active uses facing the street?
YES NO N/A YES NO
41. Does the design provide driveway access that safely manages pedestrian / bicycle conflicts with vehicles (see Section 4.8.1)?
YES NO N/A YES NO
42. Does the design provide direct, safe, and accessible connections between transit stops/stations and building access points and destinations within the site?
YES NO N/A YES NO
APPLICANT: Urban Design Component Additional Explanation / Comments:
DEPARTMENTAL REVIEW: Urban Design Component Reviewer Comments:
8
27. Does the design provide convenient bicycle connections to residences, work places, and other destinations?
YES NO N/A YES NO
APPLICANT: Bicycle Component Additional Explanation / Comments: Class 1A bicycle storage meeting the minimum required number of parking spaces is provided within the proposed parking garage. All bicycle storage will be accessible via a continuous route from the public Right-Of-Way.
DEPARTMENTAL REVIEW: Bicycle Component Reviewer Comments:
33
Philadelphia City Planning Commission
12
INTERSECTIONS & CROSSINGS COMPONENT (Handbook Section 4.9) 43. If signal cycle changes are proposed, please identify Existing and Proposed Signal Cycle lengths; if not, go to question
No. 48. SIGNAL LOCATION EXISTING
CYCLE LENGTH PROPOSED CYCLE LENGTH
DEPARTMENTAL
APPROVAL
44. Does the design minimize the signal cycle length to reduce pedestrian wait time?
YES NO N/A YES NO
45. Does the design provide adequate clearance time for pedestrians to cross streets?
YES NO N/A YES NO
46. Does the design minimize pedestrian crossing distances by narrowing streets or travel lanes, extending curbs, reducing curb radii, or using medians or refuge islands to break up long crossings? If yes, City Plan Action may be required.
YES NO N/A YES NO
47. Identify “High Priority” intersection and crossing design treatments (see Handbook Table 1) that will be incorporated into the design, where width permits. Are the following “High Priority” design treatments identified and dimensioned on the plan?
YES NO
▪ Marked Crosswalks YES NO N/A YES NO ▪ Pedestrian Refuge Islands YES NO N/A YES NO ▪ Signal Timing and Operation YES NO N/A YES NO ▪ Bike Boxes YES NO N/A YES NO
48. Does the design reduce vehicle speeds and increase visibility for all modes at intersections?
YES NO N/A YES NO
49. Overall, do intersection designs limit conflicts between all modes and promote pedestrian and bicycle safety?
YES NO N/A YES NO
APPLICANT: Intersections & Crossings Component Additional Explanation / Comments:
DEPARTMENTAL REVIEW: Intersections & Crossings Component Reviewer Comments:
Philadelphia City Planning Commission
13
ADDITIONAL COMMENTS
APPLICANT Additional Explanation / Comments:
DEPARTMENTAL REVIEW Additional Reviewer Comments:
LLCP Callowhill LLC Multi-Family Development
34
Page 1 of 2 VALID TWO YEARS FROM DATE OF ISSUANCE
February 27, 2020
Conceptual Approval Terry J. McKenna LLCP Callowhill LLC. 121 S. Broad Street, Suite 130 Philadelphia, Pennsylvania 19107 RE: Callowhill (LLCP LLC) (FY20-CALL-5892-01)
Project Address: 1306-1334 Callowhill St. Earth Disturbance: 39,483 SF Development Type: Redevelopment Flood Management District: A Watershed: Delaware Direct Sewer Type: Combined
Dear Terry, The Philadelphia Water Department (PWD) has completed its review of the Conceptual Review Submission Package for this project. PWD has determined that the project meets the requirements for Conceptual Approval. The attached plan has been stamped and mailed to the primary designer. Conceptual Approval is a preliminary approval only and does not constitute final PWD approval of the project, nor does it relieve the applicant from meeting the requirements of other City agencies. The applicant may use this letter and PWD-stamped Conceptual Stormwater Management Plan when filing for a Zoning Permit; however, PWD does not stamp Zoning Permit applications. The applicant is responsible to obtain any required federal, state, and local permits outside of this review. Below and on Page 2 of this letter are the PWD reviews applicable to this project which must be completed prior to construction activity proceeding. Please see Section 2.5 of the Manual for more information about these reviews:
1. Submit a Utility Plan to [email protected]. Utility Plan Review is required for all projects that require a building permit or are proposing connections to PWD infrastructure.
2. If water service or sewer connections/disconnections are proposed, then approvals must be obtained through PWD Water Transport Records.
3. If the project includes installation of facilities that will generate sewage, then submit to PWD Projects Control for Act 537 review.
4. Backflow prevention and cross connection control measures are required as a condition of water service, with some exceptions. Contact PWD Industrial Waste & Backflow Compliance for more information.
Page 2 of 2 VALID TWO YEARS FROM DATE OF ISSUANCE
5. Post-Construction Stormwater Management Plan (PCSMP) Review
Sincerely, Jo-Marie McNulty Sara Anderson, CFM Stormwater Plan Review Supervisor, Conceptual Stormwater Plan Review Phone: (215) 685-6387 Phone: (215) 685 - 6387 Email: [email protected] Email: [email protected]
Victoria Lenoci, LEED Green Associate Manager, Private Development Services Phone: (215) 685-6266 Email: [email protected]
Enclosures: PWD-stamped plan Cc: B. Mohl
E. Ponert E. Smith S. Chiu V. Brindisi A. Fody
N. Louis (Bohler Engineering) C. Brown (Bohler Engineer)
Development Compliance Review Path The project is subject to the Post-Construction Stormwater Management Requirements identified below. Please refer to the Development Compliance Review Path in Section 2.3.1 of the Manual for more information. Post-Construction Stormwater Management Requirements ☒☒ Water Quality ☐☐ Channel Protection ☒☒ Flood Control ☐☐ PHS Release Rate cfs/acre Expedited PCSMP Review Eligibility ☐☐ Disconnection Green Review ☐☐ Surface Green Review ☒☒ Not eligible for Expedited Review
PWD Conceptual Approval
LLCP Callowhill LLC Multi-Family Development
35
PWD Conceptual Approval
LLCP Callowhill LLC Multi-Family Development
36
Notice of: ☒☒ Refusal ☒☒ Referral Application Number: ZP-2020-000458
Zoning District(s): CMX4
Date of Refusal: 5/6/2020
Address/Location: 1306-14 CALLOWHILL ST, Philadelphia, PA 19123-3605 Parcel (PWD Record)
Page Number Page 1 of 2
Applicant Name: Adam Laver DBA: Adam E. Laver, Esquire, Blank Rome LLP
Applicant Address: Blank Rome LLP One Logan Square Philadelphia, PA 19103 USA
EXAMINER NAME PLANS EXAMINER
5/6/2020 DATE SIGNED
Application for: For lot adjustment to create one lot (Parcel “A”) from three existing lots (1306-14 Callowhill St., 1316 Callowhill St, and 1322 Callowhill St.), size and location as shown on the plans. For erection of an attached structure, size and location as shown on the plans. For use as one commercial vacant tenant space on the ground floor (separate use registration and C/O required prior to occupancy). And multi-family household living (181 dwelling units) above. For a total of 55 off-street accessory parking spaces, of which including 3 ADA Van accessible parking spaces and 4 electric car parking spaces. For one (1) loading space. And a total of 61 class I-A bicycle parking spaces on an accessible route.
The permit for the above location cannot be issued because the proposal does not comply with the following provisions of the Philadelphia Zoning Code. (Codes can be accessed at www.phila.gov.)
Code Reference Proposed Zoning is Refused for the Following:
TABLE 14-701-3 Required /
Allowable: Proposed:
Max. allowed floor area ratio FAR (% of lot area) 500% 542.6%
Code Reference Proposed Zoning is Referred for the Following:
§14-803 (1)(c) (.4) Special exemption approval is required for new accessory parking in this CMX-4 district. ONE (1) ZONING REFUSAL ONE (1) ZONING REFERRAL Fee to File Appeal: $300 NOTES TO THE ZBA: The CDR (Civic Design Review) is required as per table 14-304-2. Cc: Owner: KWIK PARK CORP
PARKWAY CORP 150 N BROAD ST PHILADELPHIA PA 19102-1424
Notice of: ☒☒ Refusal ☒☒ Referral Application Number: ZP-2020-000458
Zoning District(s): CMX4
Date of Refusal: 5/6/2020
Address/Location: 1306-14 CALLOWHILL ST, Philadelphia, PA 19123-3605 Parcel (PWD Record)
Page Number Page 2 of 2
Applicant Name: Adam Laver DBA: Adam E. Laver, Esquire, Blank Rome LLP
Applicant Address: Blank Rome LLP One Logan Square Philadelphia, PA 19103 USA
EXAMINER NAME PLANS EXAMINER
5/6/2020 DATE SIGNED
1306-14 CALLOWHILL ST, Philadelphia, PA 19123-3605 Parcel (PWD Record) Page 1 of 2
Applicant Name: Adam Laver DBA: Adam E. Laver, Esquire, Blank Rome LLP
Applicant Address: Blank Rome LLP One Logan Square Philadelphia, PA 19103 USA
Notice to Applicant: An appeal from this decision may be made to the Zoning Board of Adjustment, One Parkway Building, 1515 Arch St., 18th Fl., Phila., PA 19102 within thirty (30) days of date of Refusal / Referral. Please see appeal instructions for more information.
EXAMINER NAME PLANS EXAMINER
5/6/2020 DATE SIGNED
Application for: For lot adjustment to create one lot (Parcel “A”) from three existing lots (1306-14 Callowhill St., 1316 Callowhill St, and 1322 Callowhill St.), size and location as shown on the plans. For erection of an attached structure, size and location as shown on the plans. For use as one commercial vacant tenant space on the ground floor (separate use registration and C/O required prior to occupancy). And multi-family household living (181 dwelling units) above. For a total of 55 off-street accessory parking spaces, of which including 3 ADA Van accessible parking spaces and 4 electric car parking spaces. For one (1) loading space. And a total of 61 class I-A bicycle parking spaces on an accessible route.
The permit for the above location cannot be issued because the proposal does not comply with the following provisions of the Philadelphia Zoning Code. (Codes can be accessed at www.phila.gov.)
Code Reference Proposed Zoning is Refused for the Following:
TABLE 14-701-3 Required /
Allowable: Proposed:
Max. allowed floor area ratio FAR (% of lot area) 500% 542.6%
Code Reference Proposed Zoning is Referred for the Following:
§14-803 (1)(c) (.4) Special exemption approval is required for new accessory parking in this CMX-4 district. ONE (1) ZONING REFUSAL ONE (1) ZONING REFERRAL Fee to File Appeal: $300 NOTES TO THE ZBA: The CDR (Civic Design Review) is required as per table 14-304-2. Cc: Owner: KWIK PARK CORP
PARKWAY CORP 150 N BROAD ST PHILADELPHIA PA 19102-1424
L&I Refusal/Referral Letter
LLCP Callowhill LLC Multi-Family Development
37
PROJECT/PROPERTY INFORMATION
SQUARE FOOTAGE BEING ADDED: 184,834 SQ. FT. NUMBER OF DWELLING UNITS BEING ADDED: 181
PLEASE BE ADVISED THAT THIS FORM SHALL BE SENT TO: Gary Jastrzab, Executive Director of PCPC ([email protected]
David Schaaf, Director of Urban Design Division ([email protected])
CITY OF PHILADELPHIA - DEPARTMENT OF LICENSES AND INSPECTIONS
NAME: Richard Chen PHONE NUMBER: (215) 686-2478 EMAIL: [email protected]
EXAMINER INFORMATION
HAS THE APPLICANT REQUESTED AN EARLY REFUSAL/REFERRAL BEFORE COMPLETING A CIVIC DESIGN REVIEW? YES
APPLICANT INFORMATION
NAME: Adam Laver ADDRESS: One Logan Square Philadelphia, PA 19103
CCDDRR NNOOTTIIFFIICCAATTIIOONN TTOO PPHHIILLAA.. PPLLAANNNNIINNGG CCOOMMMMIISSSSIIOONN
DATE OF CIVIC DESIGN REVIEW DETERMINATION: 05/07/2020 SITE ADDRESS: 1306-34 Callowhill Street
Civic Design Response to Planning Commission