22
1.1.1 List of functions Note: • O: Applied, • X: Not applied, • - : No relation, • Option: Model name & price are different according to options, and assembled in factory with main unit. • Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. • Dry contact & Zone control & Auto changeover is not available which is connected with synchro. • When using synchro operation - Do not use wireless remote controller - Use only one wired remote controller in the indoor units. - Use central and function controller "PQCSB101S0" & "PQCSC101S0" only Function Category ATNH09GRLED [UT09 NRD] ATNH12GRLED [UT12 NRD] ATNH18GQLED [UT18 NQD] Air supply outlet Airflow direction control(left & right) Airflow direction control(up & down) Auto swing(left & right) Auto swing(up & down) Airflow steps(fan / cool / heat) Chaos swing Chaos wind(auto wind) Jet cool(Power wind) Swirl wind Deodorizing filter Plasma air purifier Prefilter(washable / anti-fungus) Drain pump E.S.P. control Electric heater(operation) High ceiling operation Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Standard wired remote controller Picto wired remote controlxer Deluxe wired remote controlxer Simple wired remote controller Wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control General central control(Non LGAP) Dry contact Network Soluation(LGAP) PDI(power distribution indicator) PI 485 CTIE Zone control Thermistor 4 4 4 - - - Auto Auto Auto X X X O O O 4/5/4 4/5/4 4/5/4 X X X - - - O O O O O O - - - PTPKM0 PTPKM0 PTPKM0 O O O O O O - - - - - - O O O O O O O O O O O O O O O X X X X X X O O O O O O O O O O O O X X X O O O O O O O O O O O O PQRCUSA0 PQRCUSA0 PQRCUSA0 X X X X X X X X X X X X PQWRHSF0 PQWRHSF0 PQWRHSF0 X X X PQDSB PQDSB PQDSB O O O X X X PMNFP14A0 PMNFP14A0 PMNFP14A0 X X X X X X PQRSTA0 PQRSTA0 PQRSTA0 Air flow Air purify- ing Installation Reliability Convenience Individual control Special function kit Others CAC network function 60 CST 4 - Way List of Functions 5CSL0-05B 1. Indoor units 1.1 Ceiling cassette 4-way

List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

1.1.1 List of functions

Note:• O: Applied, • X: Not applied, • - : No relation,• Option: Model name & price are different according to options, and assembled in factory with main unit.• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.• When using synchro operation

- Do not use wireless remote controller- Use only one wired remote controller in the indoor units.- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only

FunctionCategory ATNH09GRLED[UT09 NRD]

ATNH12GRLED[UT12 NRD]

ATNH18GQLED[UT18 NQD]

Air supply outletAirflow direction control(left & right)Airflow direction control(up & down)Auto swing(left & right)Auto swing(up & down)Airflow steps(fan / cool / heat)Chaos swingChaos wind(auto wind)Jet cool(Power wind)Swirl windDeodorizing filterPlasma air purifierPrefilter(washable / anti-fungus)Drain pumpE.S.P. controlElectric heater(operation)High ceiling operationHot startSelf diagnosisSoft dry operationAuto changeoverAuto cleaningAuto operation(artificial intelligence)Auto restart operationChild lockForced operationGroup controlSleep modeTimer(on/off)Timer(weekly)Two thermistor controlStandard wired remote controllerPicto wired remote controlxerDeluxe wired remote controlxerSimple wired remote controllerWired remote controller(for hotel use)Wireless remote controller(simple)Wireless LCD remote controlGeneral central control(Non LGAP)Dry contactNetwork Soluation(LGAP)PDI(power distribution indicator)PI 485CTIEZone controlThermistor

4 4 4- - -

Auto Auto AutoX X XO O O

4/5/4 4/5/4 4/5/4X X X- - -O O OO O O- - -

PTPKM0 PTPKM0 PTPKM0O O OO O O- - -- - -O O OO O OO O OO O OO O OX X XX X XO O OO O OO O OO O OX X XO O OO O OO O OO O O

PQRCUSA0 PQRCUSA0 PQRCUSA0X X XX X XX X XX X X

PQWRHSF0 PQWRHSF0 PQWRHSF0X X X

PQDSB PQDSB PQDSBO O OX X X

PMNFP14A0 PMNFP14A0 PMNFP14A0X X XX X X

PQRSTA0 PQRSTA0 PQRSTA0

Air flow

Air purify-ing

Installation

Reliability

Convenience

Individualcontrol

Special function kit

Others

CAC networkfunction

60 CST 4 - Way

List of Functions 5CSL0-05B

1. Indoor units1.1 Ceiling cassette 4-way

Page 2: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

CST 4 - Way 61

List of Functions5CSL0-05B

FunctionCategory ATNH18GPLED[UT18 NPD]

ATNH21GNLED[UT21 NND]

ATNH24GPLED[UT24 NPD]

Air supply outletAirflow direction control(left & right)Airflow direction control(up & down)Auto swing(left & right)Auto swing(up & down)Airflow steps(fan / cool / heat)Chaos swingChaos wind(auto wind)Jet cool(Power wind)Swirl windDeodorizing filterPlasma air purifierPrefilter(washable / anti-fungus)Drain pumpE.S.P. controlElectric heater(operation)High ceiling operationHot startSelf diagnosisSoft dry operationAuto changeoverAuto cleaningAuto operation(artificial intelligence)Auto restart operationChild lockForced operationGroup controlSleep modeTimer(on/off)Timer(weekly)Two thermistor controlStandard wired remote controllerPicto wired remote controlxerDeluxe wired remote controlxerSimple wired remote controllerWired remote controller(for hotel use)Wireless remote controller(simple)Wireless LCD remote controlGeneral central control(Non LGAP)Dry contactNetwork Soluation(LGAP)PDI(power distribution indicator)PI 485CTIEZone controlThermistor

4 4 4- - -

Auto Auto AutoX X XO O O

4/5/4 4/5/4 4/5/4X X X- - -O O OO O O- - -

PTPKM0 PTPKM0 PTPKM0O O OO O O- - -- - -O O OO O OO O OO O OO O OX X XX X XO O OO O OO O OO O OX X XO O OO O OO O OO O O

PQRCUSA0 PQRCUSA0 PQRCUSA0X X XX X XX X XX X X

PQWRHSF0 PQWRHSF0 PQWRHSF0X X X

PQDSB PQDSB PQDSBO O OX X X

PMNFP14A0 PMNFP14A0 PMNFP14A0X X XX X X

PQRSTA0 PQRSTA0 PQRSTA0

Air flow

Air purify-ing

Installation

Reliability

Convenience

Individualcontrol

Special function kit

Others

CAC networkfunction

Note:• O: Applied, • X: Not applied, • - : No relation,• Option: Model name & price are different according to options, and assembled in factory with main unit.• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.• When using synchro operation

- Do not use wireless remote controller- Use only one wired remote controller in the indoor units.- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only

Page 3: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

62 CST 4 - Way

List of Functions 5CSL0-05B

Note:• O: Applied, • X: Not applied, • - : No relation,• Option: Model name & price are different according to options, and assembled in factory with main unit.• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.• When using synchro operation

- Do not use wireless remote controller- Use only one wired remote controller in the indoor units.- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only

FunctionCategory ATNH24GNLED[UT24 NND]

ATNH30GPLED[UT30 NPD]

ATNH36GNLED[UT36 NND]

Air supply outletAirflow direction control(left & right)Airflow direction control(up & down)Auto swing(left & right)Auto swing(up & down)Airflow steps(fan / cool / heat)Chaos swingChaos wind(auto wind)Jet cool(Power wind)Swirl windDeodorizing filterPlasma air purifierPrefilter(washable / anti-fungus)Drain pumpE.S.P. controlElectric heater(operation)High ceiling operationHot startSelf diagnosisSoft dry operationAuto changeoverAuto cleaningAuto operation(artificial intelligence)Auto restart operationChild lockForced operationGroup controlSleep modeTimer(on/off)Timer(weekly)Two thermistor controlStandard wired remote controllerPicto wired remote controlxerDeluxe wired remote controlxerSimple wired remote controllerWired remote controller(for hotel use)Wireless remote controller(simple)Wireless LCD remote controlGeneral central control(Non LGAP)Dry contactNetwork Soluation(LGAP)PDI(power distribution indicator)PI 485CTIEZone controlThermistor

4 4 4- - -

Auto Auto AutoX X XO O O

4/5/4 4/5/4 4/5/4X X X- - -O O OO O O- - -

PTPKM0 PTPKM0 PTPKM0O O OO O O- - -- - -O O OO O OO O OO O OO O OX X XX X XO O OO O OO O OO O OX X XO O OO O OO O OO O O

PQRCUSA0 PQRCUSA0 PQRCUSA0X X XX X XX X XX X X

PQWRHSF0 PQWRHSF0 PQWRHSF0X X X

PQDSB PQDSB PQDSBO O OX X X

PMNFP14A0 PMNFP14A0 PMNFP14A0X X XX X X

PQRSTA0 PQRSTA0 PQRSTA0

Air flow

Air purify-ing

Installation

Reliability

Convenience

Individualcontrol

Special function kit

Others

CAC networkfunction

Page 4: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

CST 4 - Way 63

List of Functions5CSL0-05B

FunctionCategory ATNH42GMLED[UT42 NMD]

ATNH48GMLED[UT48 NMD]

ATNH60GMLED[UT60 NMD]

Air supply outletAirflow direction control(left & right)Airflow direction control(up & down)Auto swing(left & right)Auto swing(up & down)Airflow steps(fan / cool / heat)Chaos swingChaos wind(auto wind)Jet cool(Power wind)Swirl windDeodorizing filterPlasma air purifierPrefilter(washable / anti-fungus)Drain pumpE.S.P. controlElectric heater(operation)High ceiling operationHot startSelf diagnosisSoft dry operationAuto changeoverAuto cleaningAuto operation(artificial intelligence)Auto restart operationChild lockForced operationGroup controlSleep modeTimer(on/off)Timer(weekly)Two thermistor controlStandard wired remote controllerPicto wired remote controlxerDeluxe wired remote controlxerSimple wired remote controllerWired remote controller(for hotel use)Wireless remote controller(simple)Wireless LCD remote controlGeneral central control(Non LGAP)Dry contactNetwork Soluation(LGAP)PDI(power distribution indicator)PI 485CTIEZone controlThermistor

4 4 4- - -

Auto Auto AutoX X XO O O

4/5/4 4/5/4 4/5/4X X X- - -O O OO O O- - -

PTPKM0 PTPKM0 PTPKM0O O OO O O- - -- - -O O OO O OO O OO O OO O OX X XX X XO O OO O OO O OO O OX X XO O OO O OO O OO O O

PQRCUSA0 PQRCUSA0 PQRCUSA0X X XX X XX X XX X X

PQWRHSF0 PQWRHSF0 PQWRHSF0X X X

PQDSB PQDSB PQDSBO O OX X X

PMNFP14A0 PMNFP14A0 PMNFP14A0X X XX X X

PQRSTA0 PQRSTA0 PQRSTA0

Air flow

Air purify-ing

Installation

Reliability

Convenience

Individualcontrol

Special function kit

Others

CAC networkfunction

Note:• O: Applied, • X: Not applied, • - : No relation,• Option: Model name & price are different according to options, and assembled in factory with main unit.• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.• When using synchro operation

- Do not use wireless remote controller- Use only one wired remote controller in the indoor units.- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only

Page 5: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

64 CST 4 - Way

Specifications 5CSL0-05B

1.1.2 Specifications

Power Supply Ø/V/Hz

Cooling Capacity kW

Heating Capacity kW

Current Nominal running current A

Fan Motor Type

Fan Type

Motor Output x Number of Unit

Air Flow Rate(H/M/L) cmm

Capacitor μF/Vac

Drive

Coil Row x Column x FPI mm

Dimensions Body mm

(WxHxD) Decorative Panel mm

Weight Body kg

Decorative Panel kg

Air Filter

Sound Level (H/M/L) dB(A)+3

Piping Liquid mm

Connections Gas mm

Drain(OD/ID) mm

Dehumidification Rate l/h

Safety devices

Temperature Sensor

Referigerant

Referigerant Control

Connectable outdoor unit

Power and transmission interunit cable No.x mm2

Model

Decoration panel

ATNH09GRLED[UT09 NRD]

ATNH12GRLED[UT12 NRD]

ATNH18GQLED[UT18 NQD]

PT-UQC PT-UQC PT-UQC

Indoor unit type Ceilling Cassette - 4way

1 / 220 ~240 / 50 1 / 220 ~240 / 50 1 / 220 ~240 / 50

0.3 0.3 0.3

BLDC BLDC BLDC

Turbo Turbo Turbo

40*1 40*1 40*1

8.5 / 7.0 / 6.0 9.5 / 8.0 / 7.0 13 / 12 / 11

- - -

Direct Drive Direct Drive Direct Drive

2R x 8C x 18FPI 2R x 8C x 18FPI 2R x 10C x 18FPI

570*214*570 570*214*570 570*256*570

700*30*700 700*30*700 700*30*700

14 14 15

3 3 3

Long life filter Long life filter Long life filter

36/33/30 38/35/32 41/39/36

6.35 6.35 6.35

9.52 9.52 12.7

32 / 25 32 / 25 32 / 25

1.4 1.7 2.4

Fuse, Thermal protector for fan motor

Thermistor Thermistor Thermistor

R410A R410A R410A

EEV(Outdoor Unit) EEV(Outdoor Unit) EEV(Outdoor Unit)

Single A Single A Single A

4*0.75(Including Earth) 4*0.75(Including Earth) 4*0.75(Including Earth)

Note :1. Capacities are based on the following conditions:

Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB

Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB

Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero.

2. Without optional accessories(i.e. Plasma kit, elevation grille etc.) and with maximum airvolume (Cassette type is using PQRCUS0)3. Wiring cable size must comply with the applicable local and national code.

Conversion Formulakcal/h = kW × 859.8 CFM = CMM × 35.3

Refer to each combination table

Page 6: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

CST 4 - Way 65

Specifications5CSL0-05B

Power Supply Ø/V/Hz

Cooling Capacity kW

Heating Capacity kW

Current Nominal running current A

Fan Motor Type

Fan Type

Motor Output x Number of Unit

Air Flow Rate(H/M/L) cmm

Capacitor μF/Vac

Drive

Coil Row x Column x FPI mm

Dimensions Body mm

(WxHxD) Decorative Panel mm

Weight Body kg

Decorative Panel kg

Air Filter

Sound Level (H/M/L) dB(A)+3

Piping Liquid mm

Connections Gas mm

Drain(OD/ID) mm

Dehumidification Rate l/h

Safety devices

Temperature Sensor

Referigerant

Referigerant Control

Connectable outdoor unit

Power and transmission interunit cable No.x mm2

Model

Decoration panel

*ATNH18GPLED[UT18 NPD]

*ATNH21GNLED[UT21 NND]

ATNH24GPLED[UT24 NPD]

PT-UMC PT-UMC PT-UMC

Indoor unit type Ceilling Cassette - 4way

1 / 220 ~240 / 50 1 / 220 ~240 / 50 1 / 220 ~240 / 50

0.60 0.60 0.60

BLDC BLDC BLDC

Turbo Fan Turbo Fan Turbo Fan

124*1 124*1 60*1

17 / 15 / 13 19 / 16 / 14 17 / 15 / 13

- - -

Direct Drive Direct Drive Direct Drive

2R x 8C x 19 2R x 10C x 19 2R x 8C x 19

840*204*840 840*246*840 840*204*840

950*25*950 950*25*950 950*25*950

21 23.5 21

5 5 5

Long life filter Long life filter Long life filter

39 / 37 / 34 38 / 36 / 34 39 / 37 / 34

9.52 9.52 9.52

15.88 15.88 15.88

32 / 25 32 / 25 32 / 25

2.1 2.7 2.1

Fuse, Thermal protector for fan motor

Thermistor Thermistor Thermistor

R410A R410A R410A

EEV(Outdoor Unit) EEV(Outdoor Unit) EEV(Outdoor Unit)

Single A Single A Single A

4*0.75(Including Earth) 4*0.75(Including Earth) 4*0.75(Including Earth)

Note :1. Capacities are based on the following conditions:

Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB

Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB

Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero.

2. Without optional accessories(i.e. Plasma kit, elevation grille etc.) and with maximum airvolume (Cassette type is using PQRCUS0)3. Wiring cable size must comply with the applicable local and national code.4. "*" means high efficient indoor unit

Conversion Formulakcal/h = kW × 859.8 CFM = CMM × 35.3

Refer to each combination table

Page 7: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

66 CST 4 - Way

Specifications 5CSL0-05B

Power Supply Ø/V/Hz

Cooling Capacity kW

Heating Capacity kW

Current Nominal running current A

Fan Motor Type

Fan Type

Motor Output x Number of Unit

Air Flow Rate(H/M/L) cmm

Capacitor μF/Vac

Drive

Coil Row x Column x FPI mm

Dimensions Body mm

(WxHxD) Decorative Panel mm

Weight Body kg

Decorative Panel kg

Air Filter

Sound Level (H/M/L) dB(A)+3

Piping Liquid mm

Connections Gas mm

Drain(OD/ID) mm

Dehumidification Rate l/h

Safety devices

Temperature Sensor

Referigerant

Referigerant Control

Connectable outdoor unit

Power and transmission interunit cable No.x mm2

Model

Decoration panel

*ATNH24GNLED[UT24 NND]

ATNH30GPLED[UT30 NPD]

ATNH36GNLED[UT36 NND]

PT-UMC PT-UMC PT-UMC

Indoor unit type Ceilling Cassette - 4way

1 / 220 ~240 / 50 1 / 220 ~240 / 50 1 / 220 ~240 / 50

0.60 0.60 0.60

BLDC BLDC BLDC

Turbo Fan Turbo Fan Turbo Fan

124*1 60*1 124*1

21 / 18 / 16 19 / 17 / 15 24 / 22 / 19

- - -

Direct Drive Direct Drive Direct Drive

2R x 10C x19 2R x 8C x19 2R x 10C x 19

840*246*840 840*204*840 840*246*840

950*25*950 950*25*950 950*25*950

23 21 23.5

5 5 5

Long life filter Long life filter Long life filter

40 / 38 / 36 43 / 40 / 37 43 / 40 / 37

9.52 9.52 9.52

15.88 15.88 15.88

32 / 25 32 / 25 32 / 25

2.7 2.5 2.7

Fuse, Thermal protector for fan motor

Thermistor Thermistor Thermistor

R410A R410A R410A

EEV(Outdoor Unit) EEV(Outdoor Unit) EEV(Outdoor Unit)

Single A Single A Single A

4*0.75(Including Earth) 4*0.75(Including Earth) 4*0.75(Including Earth)

Note :1. Capacities are based on the following conditions:

Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB

Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB

Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero.

2. Without optional accessories(i.e. Plasma kit, elevation grille etc.) and with maximum airvolume (Cassette type is using PQRCUS0)3. Wiring cable size must comply with the applicable local and national code.4. "*" means high efficient indoor unit

Conversion Formulakcal/h = kW × 859.8 CFM = CMM × 35.3

Refer to each combination table

Page 8: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

CST 4 - Way 67

Specifications5CSL0-05B

Power Supply Ø/V/Hz

Cooling Capacity kW

Heating Capacity kW

Current Nominal running current A

Fan Motor Type

Fan Type

Motor Output x Number of Unit

Air Flow Rate(H/M/L) cmm

Capacitor μF/Vac

Drive

Coil Row x Column x FPI mm

Dimensions Body mm

(WxHxD) Decorative Panel mm

Weight Body kg

Decorative Panel kg

Air Filter

Sound Level (H/M/L) dB(A)+3

Piping Liquid mm

Connections Gas mm

Drain(OD/ID) mm

Dehumidification Rate l/h

Safety devices

Temperature Sensor

Referigerant

Referigerant Control

Connectable outdoor unit

Power and transmission interunit cable No.x mm2

Model

Decoration panel

ATNH42GMLED[UT42 NMD]

ATNH48GMLED[UT48 NMD]

ATNH60GMLED[UT60 NMD]

PT-UMC PT-UMC PT-UMC

Indoor unit type Ceilling Cassette - 4way

1 / 220 ~240 / 50 1 / 220 ~240 / 50 1 / 220 ~240 / 50

0.72 0.72 0.72

BLDC BLDC BLDC

Turbo Fan Turbo Fan Turbo Fan

124*1 124*1 124*1

30 / 28 / 26 34 / 32 / 30 34 / 32 / 30

- - -

Direct Drive Direct Drive Direct Drive

2R x 12C x 21 2R x12C x 21 2R x 12C x 21

840*288*840 840*288*840 840*288*840

950*25*950 950*25*950 950*25*950

26 26 26

5 5 5

Long life filter Long life filter Long life filter

46 / 44 / 40 49 / 47 / 43 49 / 47 / 43

9.52 9.52 9.52

15.88 15.88 15.88

32 / 25 32 / 25 32 / 25

3.6 4.4 5.5

Fuse, Thermal protector for fan motor

Thermistor Thermistor Thermistor

R410A R410A R410A

EEV(Outdoor Unit) EEV(Outdoor Unit) EEV(Outdoor Unit)

Single A Single A Single A

4*0.75(Including Earth) 4*0.75(Including Earth) 4*0.75(Including Earth)

Note :1. Capacities are based on the following conditions:

Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB

Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB

Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero.

2. Without optional accessories(i.e. Plasma kit, elevation grille etc.) and with maximum airvolume (Cassette type is using PQRCUS0)3. Wiring cable size must comply with the applicable local and national code.

Conversion Formulakcal/h = kW × 859.8 CFM = CMM × 35.3

Refer to each combination table

Page 9: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

68 CST 4 - Way

Dimensions 5CSL0-05B

1.1.3 Dimensions

ATN

H09

GR

LED

[UT0

9 N

RD

]A

TNH

12G

RLE

D[U

T12

NR

D]

Mod

el n

ame

Pow

er s

uppl

y

Coo

ling

Cap

acity

Hea

ting

Cap

acity

Pip

ing

Con

nect

ions

Liqu

id

Gas

Dra

in(O

D/ID

)

Ø/V

/Hz

kW kW mm

mm

mm

ATNH

09G

RLED

[UT0

9 NR

D]

1 / 2

20~2

40 /

50

6.35

9.52

32/2

5

ATNH

12G

RLED

[UT1

2 NR

D]

1 / 2

20~2

40 /

50

6.35

9.52

32/2

5

700

473

5538

0(A

ir ou

tlet h

ole)

700

378.6380(Air outlet hole)

172

378.

64-R

20 22.5

570

570

517

150

86

Ø70

517

461

523

214

53

142.

530

19

84.559.5

570

34.5

4

3 21

6

5

CH

AS

SIS

CO

DE

: TR

2.5/

3.5

kW

RE

FER

TO

EA

CH

CO

MB

INA

TIO

N T

AB

LE

No. 1 2 3 4 5 6 7 8

Par

t Nam

eR

emar

k

PT

-UQ

C

Ø70

Dec

orat

ion

pane

l

air

suct

ion

grill

e

Air

disc

harg

e gr

ille

Gas

pip

e co

nnec

tion

Liqu

id p

ipe

conn

ectio

n

Dra

in p

ipe

conn

ectio

n

Pow

er s

uppl

y co

nnec

tion

Fre

sh a

ir co

nnec

tion

8

Page 10: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

CST 4 - Way 69

Dimensions5CSL0-05B

ATN

H18

GQ

LED

[UT1

8 N

QD

]

Mod

el n

ame

Pow

er s

uppl

y

Coo

ling

Cap

acity

Hea

ting

Cap

acity

Pip

ing

Con

nect

ions

Liqu

id

Gas

Dra

in(O

D/ID

)

Ø/V

/Hz

kW kW mm

mm

mm

ATN

H18

GQ

LED

[UT1

8 N

QD

]

1/ 2

20~2

40 /

50

6.35

12.7

32/2

5

CH

AS

SIS

CO

DE

: TQ

5.0

kW

700

473

5538

0(A

ir ou

tlet h

ole)

700

378.6380(Air outlet hole)

172

378.

6

4-R20 22.5

570

570

517

517

461

523

3019 14

2.5

95.512559.5

570

7694

256

4

3 21

6

5

RE

FER

TO

EA

CH

CO

MB

INA

TIO

N T

AB

LE

No. 1 2 3 4 5 6 7 8

Par

t Nam

eR

emar

k

PT

-UQ

C

Ø70

Dec

orat

ion

pane

l

air

suct

ion

grill

e

Air

disc

harg

e gr

ille

Gas

pip

e co

nnec

tion

Liqu

id p

ipe

conn

ectio

n

Dra

in p

ipe

conn

ectio

n

Pow

er s

uppl

y co

nnec

tion

Fre

sh a

ir co

nnec

tion

150

86

Ø70

8

Page 11: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

70 CST 4 - Way

Dimensions 5CSL0-05B

*ATNH18GPLED[UT18 NPD]

ATNH24GPLED[UT24 NPD]

ATNH30GPLED[UT30 NPD]

618

950618

684840

671

787

500(Air outlet hole)

998260

500(

Air

outle

t hol

e)

4-R20

292

734

787

840

840

6080

108

5495

0

25

204

40 65

TP

1 2 3

45

6

7Ø70

66

61.5

8

Mod

el n

ame

Pow

er s

uppl

y

Coo

ling

Cap

acity

Hea

ting

Cap

acity

Pip

ing

Con

nect

ions

Liqu

id

Gas

Dra

in(O

D/ID

)

Ø/V

/Hz

kW kW mm

mm

mm

*ATN

H18

GP

LED

[UT1

8 N

PD

]

1 / 2

00~2

40 /

50

9.52

15.8

8

32 /

25

ATN

H24

GP

LED

[UT2

4 N

PD

]

1 / 2

00~2

40 /

50

9.52

15.8

8

32 /

25

ATN

H30

GP

LED

[UT3

0 N

PD

]

1 / 2

00~2

40 /

50

9.52

15.8

8

32 /

25

RE

FER

TO

EA

CH

CO

MB

INA

TIO

N T

AB

LE

No. 1 2 3 4 5 6 7 8

Par

t Nam

eR

emar

k

PT

-UM

C

Ø70

Dec

orat

ion

pane

l

air

suct

ion

grill

e

Air

disc

harg

e gr

ille

Gas

pip

e co

nnec

tion

Liqu

id p

ipe

conn

ectio

n

Dra

in p

ipe

conn

ectio

n

Pow

er s

uppl

y co

nnec

tion

Fre

sh a

ir co

nnec

tion

6.0/

7.0

kW

1. U

nit s

houl

d be

inst

alle

d in

com

plan

ce w

ith th

e in

stal

latio

n m

anua

l in

the

prod

uct b

ox.

2. U

nit s

hall

be g

roun

ded

in a

ccor

danc

e w

ith th

e lo

cal r

egul

atio

ns o

r ap

plic

able

nat

iona

l cod

es.

3. T

he u

nit i

s po

wer

ed fr

om th

e ou

tdoo

r un

it. S

o po

wer

cab

le s

houl

d be

co

nnec

ted

with

the

outd

oor

unit.

* H

igh

effic

ienc

y in

door

uni

.

Page 12: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

CST 4 - Way 71

Dimensions5CSL0-05B

*ATN

H21G

NLED

[UT2

1 NN

D]

*ATN

H24G

NLED

[UT2

4 NN

D]AT

NH36

GNL

ED[U

T36

NND]

787

840

608299

246

8084

010

860

6540

25

950

734

5450

0(A

ir ou

tlet h

ole)

500(Air outlet hole)618950

4-R20

618

292

No. 1 2 3 4 5 6 7 8

Par

t Nam

eR

emar

k

PT

-UM

C

Ø70

Dec

orat

ion

pane

l

air

suct

ion

grill

e

Air

disc

harg

e gr

ille

Gas

pip

e co

nnec

tion

Liqu

id p

ipe

conn

ectio

n

Dra

in p

ipe

conn

ectio

n

Pow

er s

uppl

y co

nnec

tion

Fre

sh a

ir co

nnec

tion

1. U

nit s

houl

d be

inst

alle

d in

com

plan

ce w

ith th

e in

stal

latio

n m

anua

l in

the

prod

uct b

ox.

2. U

nit s

hall

be g

roun

ded

in a

ccor

danc

e w

ith th

e lo

cal r

egul

atio

ns o

r ap

plic

able

nat

iona

l cod

es.

3. T

he u

nit i

s po

wer

ed fr

om th

e ou

tdoo

r un

it. S

o po

wer

cab

le s

houl

d be

co

nnec

ted

with

the

outd

oor

unit.

* H

igh

effic

ienc

y in

door

uni

.

6.0/

7.1/

10.0

kW

1 2 3

45

6

7

Ø70

65.5

79.5

8

787

671

684840

Mod

el n

ame

Pow

er s

uppl

y

Coo

ling

Cap

acity

Hea

ting

Cap

acity

Pip

ing

Con

nect

ions

Liqu

id

Gas

Dra

in(O

D/ID

)

Ø/V

/Hz

kW kW mm

mm

mm

ATN

H21

GN

LED

[UT2

1 N

ND

]

1 / 2

00~2

40 /

50

9.52

15.8

8

32 /

25

ATN

H36

GN

LED

[UT3

6 N

ND

]

1 / 2

00~2

40 /

50

9.52

15.8

8

32 /

25

ATN

H24

GN

LED

[UT2

4 N

ND

]

1 / 2

00~2

40 /

50

9.52

15.8

8

32 /

25

RE

FER

TO

EA

CH

CO

MB

INA

TIO

N T

AB

LE

Page 13: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

72 CST 4 - Way

Dimensions 5CSL0-05B

ATNH

42G

MLE

D[UT

42 N

MD]

ATNH

48G

MLE

D[UT

48 N

MD]

ATNH

60G

MLE

D[UT

60 N

MD]

Mod

el n

ame

ATN

H42

GM

LED

[UT4

2 N

MD

]

1 / 2

20 ~

240

/ 50

9.52

15.8

8

32 /

25

ATN

H48

GM

LED

UT4

8 N

MD

]

1 / 2

20 ~

240

/ 50

9.52

15.8

8

32

/ 25

ATN

H60

GM

LED

[UT6

0 N

MD

]

1 / 2

20 ~

240

/ 50

9.52

15.8

8

32 /

25

TM

684

840

78

787

840

110

6080

840

70135

148

25

40

183288

950

734

5450

0(A

ir ou

tlet h

ole)

500(Air outlet hole)618950

671

4-R20

618

292

RE

FER

TO

EA

CH

CO

MB

INA

TIO

N T

AB

LE

12.5

/14.

0/15

.0 k

W

1 2 3

45

6

7

Ø70

66

109

8

787

No. 1 2 3 4 5 6 7 8

Par

t Nam

eR

emar

k

PT

-UM

C

Ø70

Dec

orat

ion

pane

l

air

suct

ion

grill

e

Air

disc

harg

e gr

ille

Gas

pip

e co

nnec

tion

Liqu

id p

ipe

conn

ectio

n

Dra

in p

ipe

conn

ectio

n

Pow

er s

uppl

y co

nnec

tion

Fre

sh a

ir co

nnec

tion

Page 14: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

CST 4 - Way 73

Piping diagrams5CSL0-05B

1.1.4 Piping diagrams

Heat exchanger

Th3

Th1

Gas pipe connection port(flare connection)

Th2

Th1 : Thermistor for suction air temp.Th2 : Thermistor for liquid line temp.Th3 : Thermistor for gas line temp.

Liquid pipe connection port(flare connection)

Turbo fanCooling

Heating

■ Refrigerant pipe connection port diameters

Model Gas Liquid

ATNH09GRLED[UT09 NRD]Ø9.52 Ø6.35

ATNH12GRLED[UT12 NRD]

ATNH18GQLED[UT18 NQD] Ø12.7 Ø6.35

ATNH18GPLED[UT18 NPD]

ATNH21GNLED[UT21 NND]

ATNH24GNLED[UT24 NND]

ATNH24GPLED[UT24 NPD]

ATNH30GPLED[UT30 NPD] Ø15.88 Ø9.52

ATNH36GNLED[UT36 NND]

ATNH42GMLED[UT42 NMD]

ATNH48GMLED[UT48 NMD]

ATNH60GMLED[UT60 NMD]

[Unit:mm]

Page 15: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

74 CST 4 - Way

Wiring diagrams 5CSL0-05B

CONNECTOR NUMBER LOCATION POINT FUNCTION

CN-POWER AC POWER SUPPLY AC POWER LINE INPUT FOR INDOOR CONTROLLER

CN-MOTOR1 FAN MOTOR OUTPUT MOTOR OUTPUT OF BLDC

CN-D/PUMP DRAIN PUMP OUTPUT AC OUTPUT FOR DRAIN PUMP

CN-DISP DISPLAY DISPLAY OF INDOOR STATUS

CN-VANE1 / VANE2 STEP MOTOR STEP MOTOR OUTPUT

CN-FLOAT FLOAT SWITCH INPUT FLOAT SWITCH SENSING

CN-PIPE/IN SUCTION PIPE SENSOR PIPE IN THERMISTOR

CN-PIPE/OUT DISCHARGE PIPE SENSOR PIPE OUT THERMISTOR

CN-ROOM ROOM SENSOR ROOM AIR THERMISTOR

CN-REMO REMOTE CONTROLLER REMOTE CONTROL LINE

CN-CC DRY CONTACT DRY CONTACT LINE

1) Wiring diagrams1.1.5 Wiring diagrams

CN_POWER

CN_D/PUMP

CN_MOTOR

CN_VANE2 CN_VANE1

CN_FLOAT CN_DISPLAY

CN_OPTION

CN_REMO

CN_ROOM

CN_PIPE/IN

CN_PIPE/OUT

SW012) PCB

Page 16: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

CST 4 - Way 75

Air flow and temperature distributions (reference data)5CSL0-05B

1.1.6 Air flow and temperature distributions (reference data)

Model : 2.5kW/3.5kW

Cooling HeatingDischarge angle: 40°

Air velocity [m/s]

Temperature [°C]

2.7m

2m

1m

0m1.5m 1.5m2.5m 2.5m0m

2.02.0

1.51.5

1.01.0

0.50.5

2.7m

2m

1m

0m1.5m 1.5m2.5m 2.5m0m

1818

2020

2222

2424

Discharge angle: 50°

Air velocity [m/s]

Temperature [°C]

2.7m

2m

1m

0m1.5m 1.5m2.5m 2.5m0m

2.02.01.51.5

1.01.0

0.50.5

2.7m

2m

1m

0m1.5m 1.5m2.5m 2.5m0m

3333

3030

27272424

2121

Discharge angle: 40°

Air velocity [m/s]

Temperature [°C]

2.7m

2m

1m

0m4m3m3m4m 2m2m 1m1m 0m

2.7m

2m

1m

0m4m3m3m4m 2m2m 1m1m 0m

18182020

2222

2424

2.02.0

1.51.5

1.01.0

0.50.5

Discharge angle: 50°

Air velocity [m/s]

Temperature [°C]

2.7m

2m

1m

0m4m3m3m4m 2m2m 1m1m 0m

2.7m

2m

1m

0m4m3m3m4m 2m2m 1m1m 0m

2.02.0

1.51.5

1.01.0

0.50.5

3333

3030

27272424

2121

Model : 5.0kW

Cooling Heating

Page 17: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

76 CST 4 - Way

5CSL0-05BAir flow and temperature distributions (reference data)

Model : 6.0kW/7.1kW

Cooling Heating

Model : 8.0kW

Cooling Heating

Discharge angle: 40°

Air velocity [m/s]

Temperature [°C]

2.7m

2m

1m

0m4m3m3m4m 2m2m 1m1m 0m

2.7m

2m

1m

0m4m3m3m4m 2m2m 1m1m 0m

2.02.0

1.5 1.5

1.01.0

Discharge angle: 50°

Air velocity [m/s]

Temperature [°C]

2.7m

2m

1m

0m4m3m3m4m 2m2m 1m1m 0m

2.7m

2m

1m

0m4m3m3m4m 2m2m 1m1m 0m

333330 30

27272424

2222

2424

2.0 2.0

1.01.0

0.50.5

201818

202222

2323

Discharge angle: 40°

Air velocity [m/s]

Temperature [°C]

2.7m

2m

1m

2.7m

2m

1m

2.02.52.5

3.0 3.0

2.0

1.51.5

1.01.0

Discharge angle: 50°

Air velocity [m/s]

Temperature [°C]

2.7m

2m

1m

2.7m

2m

1m

30 30

27 27

24242222

2323

18

2020

2222

0m4m 5m3m5m 2m1m1m 0m3m 2m4m

0m4m 5m3m5m 2m1m1m 0m3m 2m4m

0m4m 5m3m5m 2m1m1m 0m3m 2m4m

0m4m 5m3m5m 2m1m1m 0m3m 2m4m

3.53.03.0

3.5

2.52.5

2.02.0

1.01.0

18 33 33

Page 18: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

CST 4 - Way 77

5CSL0-05B Air flow and temperature distributions (reference data)

Model : 10.0kW

Cooling Heating

Model : 12.5kW

Cooling HeatingDischarge angle: 40°

Air velocity [m/s]

Temperature [°C]

4.04.0

3.03.0

2.02.01.01.0

Discharge angle: 50°

Air velocity [m/s]

Temperature [°C]

3.2m

0m4m 5m3m5m 2m1m1m 0m

2m

1m

3m 2m4m

3.2m

0m4m 5m3m5m 2m1m1m 0m

2m

1m

3m 2m4m

3.2m

0m4m 5m3m5m 2m1m1m 0m

2m

1m

3m 2m4m

3.2m

0m4m 5m3m5m 2m1m1m 0m

2m

1m

3m 2m4m

24

33 33

24

27 27

30 30

2222

4.04.0

3.0 3.0

2.02.0

1.01.0

1818

2020

22222424

Discharge angle: 40°

Air velocity [m/s]

Temperature [°C]

2.7m

2m

1m

2.7m

2m

1m

2.02.52.5

3.0 3.0

2.0

1.51.5

1.01.0

Discharge angle: 50°

Air velocity [m/s]

Temperature [°C]

2.7m

2m

1m

2.7m

2m

1m

30 30

27 27

24242222

2323

18

2020

2222

0m4m 5m3m5m 2m1m1m 0m3m 2m4m

0m4m 5m3m5m 2m1m1m 0m3m 2m4m

0m4m 5m3m5m 2m1m1m 0m3m 2m4m

0m4m 5m3m5m 2m1m1m 0m3m 2m4m

3.53.03.0

3.5

2.52.5

2.02.0

1.01.0

18 33 33

Page 19: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

78 CST 4 - Way

5CSL0-05B

Model : 14.0kW/15.0kW

Cooling Heating

Discharge angle: 40°

Air velocity [m/s]

Temperature [°C]

Discharge angle: 50°

Air velocity [m/s]

Temperature [°C]

3.2m

0m4m 5m3m5m 2m1m1m 0m

2m

1m

3m 2m4m

3.2m

0m4m 5m3m5m 2m1m1m 0m

2m

1m

3m 2m4m

3.2m

0m4m 5m3m5m 2m1m1m 0m

2m

1m

3m 2m4m

3.2m

0m4m 5m3m5m 2m1m1m 0m

2m

1m

3m 2m4m

1

1.5

22.5

0.5

1

1.5

22.5

0.5

23.9

23.9 22.421.0

20.3

19.2

18.2

23.9

23.922.421.0

20.3

19.2

18.2

0.510.5

1.5

2

2.5

0.5 10.5

1.5

2

2.5

34.3

32.8

31.4 30.8

34.3

32.8

31.430.8

27.4

28.6

25.327.4

28.6

25.3

Air flow and temperature distributions (reference data)

Page 20: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

CST 4 - Way 79

5CSL0-05B Sound levels

1.1.7 Sound levels

Notes:- Sound measured at 1.5m below the center of the unit.- Data is valid at free field condition- Data is valid at nominal operation condition- Reference accoustic pressure OdB = 20μPa - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.- The operating conditions are assumed to be standard.

1.5m

Ceiling

Octave Band Center Frequency (Hz)

Sou

nd P

ress

ure

Leve

l (dB

re

20uP

a)

10

20

30

40

50

60

70

80

63 125 250 500 1000 2000 4000 8000NC-15

NC-20

NC-25

NC-30

NC-35

NC-40

NC-45

NC-50

NC-55

NC-60

NC-65

ApproximateHearingThreshold

Octave Band Center Frequency (Hz)

So

un

d P

ress

ure

Le

vel (

dB

re

20

μP

a )

10

20

30

40

50

60

70

80

63 125 250 500 1000 2000 4000 8000NC-15

NC-20

NC-25

NC-30

NC-35

NC-40

NC-45

NC-50

NC-55

NC-60

NC-65

ApproximateHearingThreshold

Octave Band Center Frequency (Hz)

Oct

ave

Ban

d S

ound

Pre

ssur

e Le

vel (

dB r

e 20

Pa

)

s

10

20

30

40

50

60

70

80

63 125 250 500 1000 2000 4000 8000NC-15

NC-20

NC-25

NC-30

NC-35

NC-40

NC-45

NC-50

NC-55

NC-60

NC-65

ApproximateHearingThreshold

10

20

30

40

50

60

70

80

90

63 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz)

NC-15

NC-70

NC-65

NC-60

NC-55

NC-50

NC-45

NC-40

NC-35

NC-30

NC-25

NC-20

Sou

nd P

ress

ure

Leve

l (dB

re

20uP

a)

10

20

30

40

50

60

70

80

90

63 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz)

NC-15

NC-70

NC-65

NC-60

NC-55

NC-50

NC-45

NC-40

NC-35

NC-30

NC-25

NC-20

Sou

nd P

ress

ure

Leve

l (dB

re

20uP

a)

10

20

30

40

50

60

70

80

90

NC-15

NC-70

NC-65

NC-60

NC-55

NC-50

NC-45

NC-40

NC-35

NC-30

NC-25

NC-20

Sou

nd P

ress

ure

Leve

l (dB

re

20μP

a )

Octave Band Center Frequency (Hz)

63 125 250 500 1000 2000 4000 8000

Sound pressure levelATNH09GRLED [UT09 NRD]ATNH12GRLED [UT12 NRD]

ATNH18GQLED [UT18 NQD] ATNH24GPLED [UT24 NPD]

ATNH30GPLED [UT30 NPD] *ATNH21GNLED [UT21 NND]

*ATNH18GPLED [UT18 NPD]*ATNH24GNLED [UT24 NND]ATNH36GNLED [UT36 NND]

Overall

* High Efficiency Indoor units

Page 21: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

80 CST 4 - Way

5CSL0-05BSound levels

Octave Band Center Frequency (Hz)

So

un

d P

ress

ure

Le

vel (

dB

re

20

μP

a )

10

20

30

40

50

60

70

80

63 125 250 500 1000 2000 4000 8000

NC-15

NC-20

NC-25

NC-30

NC-35

NC-40

NC-45

NC-50

NC-55

NC-60

NC-65

ApproximateHearingThreshold

Octave Band Center Frequency (Hz)

So

un

d P

ress

ure

Le

vel (

dB

re

20

μP

a )

10

20

30

40

50

60

70

80

63 125 250 500 1000 2000 4000 8000NC-15

NC-20

NC-25

NC-30

NC-35

NC-40

NC-45

NC-50

NC-55

NC-60

NC-65

ApproximateHearingThreshold

ATNH42GMLED [UT42 NMD] ATNH48GMLED[UT48 NMD]ATNH60GMLED[UT60 NMD]

Page 22: List of Functions 5CSL0-05B 1. Indoor unitssanitor.fr/LG_TECHNIQUE_2010/PDB/5CSL0-05B_UT.pdf · Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly)

CST 4 - Way 81

5CSL0-05B

1.1.8 ControllerController

■ Wired remote controller

1

9

11

12

3

5

6

2

4 10

13

14

7

8

15

1. Operation indication screen

2. Set temperature button

3. Wireless remote controller Receiver• Some products don't receive the wireless signals.

4. Ventilation button

5. Operation mode selection button

6. Subfunction button

7. Function setting button

8. Exit button

9. On/ Off button

10. Room temperature button

11. Fan speed button

12. Air flow button

13. Reservation/ Time setting button

14. Setting/ Cancel button

15. Up, Down, Left, Right button

Note

❈ Display temperature can be different from actual room temperature if the remote controller is installed at the place wheresun-rays are falling directly or the place nearby heat source.

❈ The actual product can be different from above contents depending upon model type.