16
Lingenfelter VSFM-002 Variable Speed DC Brushless Fan & Pump Controller Instructions Lingenfelter Performance Engineering 1557 Winchester Road Decatur, IN 46733 (260) 724-2552 (260) 724-8761 fax www.lingenfelter.com Release date: 8 September 2016 Revision - 1.8 PN: L460320002

Lingenfelter VSFM-002 Variable Speed DC Brushless Fan ... Controlled PWM Mode: To enter Temperature Controlled PWM Mode, DIP switch #3 must be in the DOWN position. Device operation:

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Lingenfelter VSFM-002 Variable Speed DC Brushless

Fan & Pump Controller Instructions

Lingenfelter Performance Engineering1557 Winchester Road

Decatur, IN 46733(260) 724-2552

(260) 724-8761 faxwww.lingenfelter.com

Release date: 8 September 2016Revision - 1.8

PN: L460320002

Page 2

Parts ListLingenfelter VSFM-002 Variable Speed DC Brushless

Fan & Pump Controller (PN: L460320002)

# Description Part number1 Variable speed control module VSFM-0022 Hook & loop tape2 Self-tapping screw AV160371 LPE decal L9200100001 Instructions

Tools & Materials Required• Phillips head screwdriver• Wire crimping tool

Optional Items Description Part number

LPE technician’s screwdriver L950050000

Description:The Lingenfelter VSFM-002 is designed to provide the PWM speed control signal needed to operate variable speedOEMandaftermarketDCbrushlesscoolingfansandfluidcirculationpumps.Thespeedcanbecontrolledbasedonatemperatureinputsignal(e.g.ResistiveTemperatureDetector(RTD)orThermistor)orasimpleswitchedinputforon/offtypecontrol.TheVSFM-002alsohasarelaycontroloutputtocontrolawarninglightorauxiliarydevice.

• WorkswithOEMandaftermarketIAT,ECT,EGT,TFTsensorsincluding(moreonpage12):

• GMIAT(12160244/12614717)

• ECT(12608814/12636612)

• TFT(12458118)

• Oiltemperaturesensors(15326388)

• Bosch 2780071435, 2782569739, 2782650379, 2782610059, 0280130039

• AEM30-2012andothersimilarfluidtemperaturesensors

• WorkswithOEMandaftermarketEGT&platinumRTDsensors,including(moreonpage12):

• AEM 30-2050

• GM 12636612

• ACDelco 213-4695

• Bosch PT 200E

• Sensata TS200-A

• PT200RTD

• Works with OEM and aftermarket DC brushless electric fans & coolant pumps made/ sold by:

• GM,Bosch,CooperIndustries,Pierburg,andotherstobeadded.

• Works with SPAL OEM and aftermarket NUOVA DC brushless fans, including the “Standard Series” and thenewer“PlusSeries”fans.

The VSFM-002 can replace the following SPAL sensors: SBL-TS01, SBL-TS02, SBL-TS03, SBL-TS215P, SBL-TS185P,SBL-TS165P.

Page 3

Specifications• Two sets of easily adjustable device control switches

• “StartTemp”setstheinitialontemperatureforthedevice(s)

• “MaxOutputTemp”setsthetemperatureforthemaximumdevicespeed.

• The VSFM-002 provides a linear output speed control between these two settings

• Thesameswitchesarealsousedtosetspeed%indirectdevicespeedcontrolmode.

• Canbeusedtocontrolmultipledevices(alldevicesmustbethesameinputtype)

• Available output types:

• OutputshaveaselfprotectfeatureandwillturnOFFincaseofdirectshortorovercurrentcondition.

• Twofrequencybasedoutputwires(1-250Hz)

• Push-pull +12V peak output

• Open drain ground control type output

• RelayOutput-Therelaycontroloutputwilloutputagroundsignalwhenthefanisoperatingatmaximumspeed.Therelaycontroloutputisintendedtocontrolawarninglightorauxiliarydevice,suchasanadditionalfan.

• Outputratedforupto0.75Amps.

• Analog Output signal

• Outputananalog,0-5Volts,signalbasedontemperatureorfan/pumpspeed%.

• Sendtemperatureorfan/pumpspeedtoanECM,dataacquisitionsystem,oragauge.

• Oneinputmanualoverride/activationwireavailable(ACrelatedactivation,manualoverride,etc.):

• Inputsignalimpedance:100kOhms.

• +12VorgroundactivationsignalwiredeterminedbyaDIPswitchinsidethebackcover.

• The DIP switch enables and disables a pull-up resistor

• Pull-up enabled - ground activation

• Pull-up disabled - +12V activation

• Operatingvoltagerange:9.0to18.0volts.

• Currentdraw:(max4amps)0.1amppluscurrentdrawofdevicebeingcontrolled

• The temperature switch settings can be adjusted in 10 degree increments from 0 to 990 degrees.

• IAT, ECT, and TFT (thermistor) sensors are in Fahrenheit (F)

• EGT/platinum RTD sensors, due to the larger temperature range, are in Celsius (C).

• CustommoldedhightemperatureglassfilledNylon6enclosure.

• Fullyencapsulated(potted)constructionforincreaseddurability.

• Oneyearwarranty(fromdateofpurchase).

Page 4

Settings on the front face of the VSFM-002:• Singlesixteenpositionswitchforselectingthetypeofdevicetobecontrolled.

• Two ten position switches for selecting the temperature* at which thefan/pumpisatitsminimumspeed.

• StartTemp(DegF)x100**

• StartTemp(DegF)x10**

• Two ten position switches for selecting the temperature* at which thefan/pumpisatitsmaximumspeed.

• MaxOutputTemp(DegF)x100**

• MaxOutputTemp(DegF)x10**

• MaxOutputTempMUSTBEGREATERTHANStartTempwheninTEMPERATURECONTROLLEDPWMmode.

*When in User Controlled Fan/Pump Speed % Mode, the dials set percentage.**When using EGT/ RTD sensors, the dials are in Degrees Celsius (see table 3 for Celsius/Fahrenheit Conversion)

Table 1: Wiring (also labeled on module)Wire Color Label Notes NotesRed +12V Switched Power Connectstoaswitchedandfused+12Vsource.Blue Analog Out This wire provides a variable 0-5 V output based

onfan/pumpspeedortemperature.Orange PWM Out, +12V Thiswireprovidesa+12Vpush-pullpeakoutput.Black Ground Connectstoavehicleground.Purple Sensor Signal Connects to output of SensorBrown Sensor Ground Connects to ground of SensorGray RelayOutput Connects to the ground side of the device you

wishtocontrol(rated0.75Amps).Yellow PWM Out, Ground Thiswireprovidesopendraingroundcontrol.White Override Input This connects to a device that will provide a

+12Vorgroundsignaltoactivatethemodule.

Power

VSFM-002Temperature BasedPWM Ouput Module

Ground - Black

Relay Output - GrayPWM Out, Ground - Yellow

x100

x10

+12V Switched Power - Red

Start Temp (Deg F)

x10x100

Max Output Temp (Deg F)

Sensor Signal - Purple

PWM Out,+12V - Orange

Override Input - White

Analog Out Signal - Blue

Sensor Ground - Brown

Device Select

Page 5

Settings inside the rear cover of the VSFM-002:• FivetwopositionDIPswitches(thelocationoftheseswitchesareshownintheimagebelow).

• Sensor Selection

• DIP switch #1 and #2 selects the temperature sensor (more information relating to sensors is located on page 11).

Sensor Type(see Table 3)

DIP Switch#1 #2

GM/ECT/IAT/TFT (Type 1)

AEM ECT (Type 2)

GM EGT RTD (Type 3)

Bosch ECT/IAT (Type 4)

• Control Mode Selection

• DIPswitch#3selectsthedesiredfan/pumpcontrolmode.

Fan/Pump Control ModeDIP Switch

#3Temperature Controlled

PWM modeUser Controlled

Fan/Pump Speed % mode• Override Input Activation Polarity Selection

• DIPswitch#4and#5selectstheOverrideInputActivationpolarity.

Activation PolarityDIP Switch

#4 #5

+12V Activation

GND Activation

• If DIP switch #4 and #5 are not in the same positions as one of the combinations listed above, you WILL NOT get the output you expect unless you are using the advanced settings.

• AdvancedsettingsarelocatedinAppendixA.

• Onepush-buttonisusedforProgrammingMode(selectstheAnalogOutoutputtype).

Page 6

Push-Button Programming Mode:ProgrammingmodeisusedtoprogramtheAnalogOutoutputontheVSFM-002.TherearetwooptionsfortheAnalogOutoutput.TheVSFM-002canoutputananalogvoltagebasedoneithertemperatureorfan/pumpspeed.

IfyouarenotplanningonusingtheAnalogOutoutput,youdonotneedtoprogramthisfeature.• The default Analog Out output is temperature based.

• When the temperature option is selected, the Analog Out will output a 0-5V(+/-0.02V)linearanalogsignaldependentonthetemperaturesensoryouhavechosen(moreinformationonpage11and12).

• GM ECT/IAT/TFT, AEM ECT, and the Bosch IAT/ECT sensors:

• 0.02V≈1.4DegF

• 0-350 Deg F

• 0.00V=0DegF

• 5.00V=350DegF

• GM/AEM/Bosch/SensataEGTPlatinumRTDsensors:

• 0.02V≈5DegC(9.1DegF)

• 0-1275 Deg C

• 0.00V=0DegC(32DegF)

• 5.00V=1275DegC(2327DegF)

• Whenthespeedoptionisselected,theAnalogOutwilloutputa0-5V(+/-0.02V)linearanalogsignaldependentonthecurrentspeed(0-100%)ofthefan/pump.AnalogOutwilloutput0.00Vat0%,andAnalogOutwilloutput5.00Vat100%.

To enter Programming Mode:

• Ignitionoff(VSFM-002poweroff)

• Set all four 10 position switches to 0 and the 16 position switch to0.The“StartTemp”settingswitchesshouldbepointingtotheright, the “Max Output Temp” setting switches should be pointing down, and the “Device Select” 16 position switch should be pointingup.Seeillustrationontherightforswitchpositions.

• Ignition on

• TheLEDshouldnowblinkgreen.

• PressthebrownPROGRAMbuttononthebackoftheVSFM-002totogglebetweenthedifferentAnalogOut options:

Analog Out LEDTemperature Blinking GREEN

Speed Blinking RED• AfteryouhaveselectedthecorrectAnalogOutoption,pressandholdthebrownPROGRAMbuttononthe

backoftheVSFM-002untiltheLEDbeginsblinkingREDandGREEN(approximately3seconds).

• ToexitProgrammingMode,turnofftheunit(ignitionoff)andwhiletheVSFM-002ispoweredoffsetthefrontcoverswitchestothedesiredsettings.

Power

VSFM-002Temperature BasedPWM Ouput Module

Ground - Black

Relay Output - GrayPWM Out, Ground - Yellow

x100

x10

+12V Switched Power - Red

Start Temp (Deg F)

x10x100

Max Output Temp (Deg F)

Sensor Signal - Purple

PWM Out,+12V - Orange

Override Input - White

Analog Out Signal - Blue

Sensor Ground - Brown

Device Select

Program Button

Page 7

Device Select:Table2belowliststhecurrentfans/pumpsthattheVSFM-002canoperate.Thetableisnotlimitedtothementioneddevices.IfyourdevicehasthesameparametersastheoneslistedinTable2,youcanusetheVSFM-002tocontrolyourdevice.Thetabledefinitionsarelistedbelow:

• DeviceSelect-selectsthefan/pumpyouwishtocontrol.LocatedonthefrontoftheVSFM-002(0-F16positionswitch).

• Polarity:

• Positive-yourdevicereadsthehighvoltagesideofthePWMsignal.

• Negative-yourdevicereadsthelowvoltagesideofthePWMsignal.

• Frequency(Hz)-thefrequencyatwhichyourdeviceoperates.

• OffDuty%-thedutycycleyourdeviceneedsforyourdevicetobeoff.

• MinDuty%-thedutycycleyourdeviceneedstorunatminimumspeed.

• MaxDuty%-thedutycycleyourdeviceneedstorunatmaximumspeed.

• Failure Duty % - Your device will run at this duty cycle when the VSFM-002 recognizes that a temperature sensorisnotconnectedwheninTEMPERATURECONTROLLEDPWMmode.

Table 2: Device Select

Fan/Pump Device Select Polarity Frequency

(Hz)Off Duty

%Min Duty

%Max Duty

%Failure Duty %

SPALNONPLUSSERIESC7CORVETTEOEMFAN*

0 NEGATIVE 100 5 15 90 90

SPALPLUSSERIESFAN* 1 POSITIVE 100 5 15 90 90

COOPER&VARIMAXPUMP 2 POSITIVE 2 10 20 80 80

C6CORVETTEFANCONTROLMODULEPN:10377609(GM)

4 NEGATIVE 128 5 10 90 90

BOSCHGMCKTRUCKFAN 5 NEGATIVE 100 5 10 90 90

PIERBURGCWA50/200PUMP 6 POSITIVE 100 9 13 85 85

PIERBURGCWA100/BOSCH PUMP PN: 0 392 024 058

7 POSITIVE 100 9 13 93 93

PIERBURGCWA400PUMP 8 POSITIVE 100 9 13 86 86

BOSCH FAN PN: 0 130 706 816 9 POSITIVE 50 5 15 85 85

PROTECHNICPN:MGT1724UB-W51 A POSITIVE 50 5 16 100 100

*For more information regarding SPAL fans, see APPENDIX B (page 14).

Page 8

Temperature Controlled PWM Mode:ToenterTemperatureControlledPWMMode,DIPswitch#3mustbeintheDOWNposition.

Device operation:TheTemperatureControlledPWMmodeiscontrolledbytemperature.Thespeedofthefan/pumpwillincreaselinearlywithinputtemperaturesbetweenStartTempandMaxOutputTemp.WhentheinputtemperatureislessthanStartTemp,thefan/pumpwillbeoff.WhentheinputtemperatureisequaltoStartTemp,thefan/pumpwilloperateatminimumspeed.WhentheinputtemperatureisgreaterthanorequaltotheMaxOutputTemp,thefan/pumpwilloperateatmaximumspeed.

WhentheOverrideInputisactivated,thefan/pumpwilloperateatmaximumspeed.IftheVSFM-002recognizesthatatemperaturesensorisnotconnected,thecontrollerwillgointofailuremode.Failuremodewillcausethefan/pumptorunatmaximumspeed.

RelayOutputWire-Therelaycontroloutputwilloutputagroundsignalwhenthefanisoperatingatmaximumspeed.Therelaycontroloutputisintendedtocontrolawarninglightorauxiliarydevice.

LED operation:• SolidREDindicatesthatthefan/pumpisoff.• SolidGREENindicatesthattheinputtemperatureisbetweenStartTempandMaxOutputTemp(fan/pump

operatingrange).• BlinkingGREENindicatesthattheinputtemperatureisgreaterthanorequaltoMaxOutputTemp(fan/

pumpmaxspeed).• BlinkingREDandGREENindicatesthattheOverrideinputinactive(fan/pumpmaxspeed).• BlinkingREDindicatesthatStartTempisgreaterthanorequaltoMaxOutputTemp,orthereisno

temperaturesensorconnectedtotheVSFM-002.

Page 9

User Controlled Fan/Pump Speed % Mode:ToenterUserControlledFan/PumpSpeed%Mode,DIPswitch#3mustbeintheUPposition.

Note - You will only need a temperature sensor in this mode if you are using Analog Out to output a 0-5 V signalbasedontemperature.Thetemperaturesensordoesnotcontrolthespeedofthefan.

Speed Control:

• 0%isoff.

• 1%isminimumspeed.

• 99%iscontrolleroutputmaximumspeed.

• Actualspeedpercentageis+/-1%.

Device operation:TheUserControlledFan/PumpSpeed%iscontrolledbyuserinput.Inthismode,theStartTempdialsfunctionastheStartingSpeed%,andtheMaxOutputTempdialsfunctionasInputActivatedSpeed%.Theconversionfrom Temperature to Speed % is as follows: 10 Degrees in Temperature Controlled PWM Mode = 1% in User Controlled Fan/Pump Speed % Mode. An EXAMPLE LABEL* for the USER CONTROLLED FAN/PUMP SPEED % Mode is shown in the image below.

Power

VSFM-002Temperature BasedPWM Ouput Module

Ground - Black

Relay Output - GrayPWM Out, Ground - Yellow

x10

x1

+12V Switched Power - Red

Starting Speed %

x1x10

Input Activation Speed %

Sensor Signal - Purple

PWM Out,+12V - Orange

Override Input - White

Analog Out Signal - Blue

Sensor Ground - Brown

NOT THE ACTUAL LABEL

Device Select

*Note: this is not the actual label of the VSFM-002. This label is used here for the sole purpose of showing how the module operates when in the User Controlled Speed % Mode.

In the example shown above, the starting speed %

TheFan/Pumpspeedpercentagepertainstothefan/pumpdeviceselectchart(Table2).

0%=OffDuty%

1%=MinDuty%

99%=MaxDuty%

WhentheVSFM-002ispoweredon,thefan/pumpwillbegintooperateattheStartingSpeed%.OncetheVSFM-002OverrideInputisactive,thefan/pumpwilloperateattheInputActivatedSpeed%.

Ifyouwantthepump/fanoffwhentheOverrideInputisnotactive,setStartingSpeed%to0.ThensetInputActivationSpeed%tothedesiredactivationspeed%.

NOTE: StartingSpeed%doesnothavetobelessthanInputActivationSpeed%inthismode.

LED operation:• SolidGREENindicatesOverrideInputactivationisinactive.• SolidREDindicatesOverrideInputactivationisactive.

Page 10

Installation:1. Disconnectthenegativebatteryterminal.2. ConnecttheblackwireofVSFM-002tooasuitablevehicleground.Failure to fully secure the ground

wire to a vehicle ground source could result in malfunction of the module.3. Connect the red wire to a switched and fused+12voltDCsource.A5-10ampfuseshouldbesufficient.4. ConnectthegrayRelayOutputwiretothegroundsideofthedeviceyouwishtocontrol.

• Arelayshouldbeusediftherelaycontroloutputwillbecontrollingadevicethatpullsmorethan0.75amps.

5. ConfiguretheDIPswitchsettingsbehindthebackcoveroftheVSFM-002.6. ConnectthePurpleandBrownWiretoatemperaturesensor.7. ConnectthewhitewiretoadesiredactivationsourceifusingtheOverrideInput.8. ConnectthePWMsignalwiretothefan/pumpyouwillbecontrolling(seeTable2onpage7).

• If the fan/pump you are connecting to has an internal pull-up resistor, connect the yellow PWM Out, Ground,tothePWMinputonthefan/pump.

• If the fan/pump you are connecting to does not have an internal pull-up resistor, connect the orange PWMOut,+12V,tothePWMinputofthefan/pump.

9. SecuretheVSFM-002usingthesuppliedhookandlooptapeorusingthesuppliedself-tappingscrews.10.AdjustthedialsonthefrontoftheVSFM-002todesiredsettings.11.Reconnectthenegativebatteryterminal.

Additional Notes and Warnings:• ChangestotheswitchsettingsmustbedonewiththeVSFM-002poweredoff.

• Theswitchpositionsareonlyreadonstartup(initialdevicepowerup).

• ThelowTemperatureSetting(StartTemp)mustbelessthanthehighTemperatureSetting(MaxOutputTemp)wheninTemperatureControlledPWMMode.

• The VSFM-002 will not work on fans/pumps that require more than 250 Hz or less than 1 Hz for the PWM signal.

• MakesurethattheVSFM-002groundwireisproperlysecuredtoavehicleground.FailuretofullysecuretheVSFM-002groundwiretoavehiclegroundsourcecouldcausetheVSFM-002tomalfunction.

• DoNOTsubmergethemoduleinliquidordirectlywashtheunitwithliquidofanytype.Theswitchesonthe VSFM-002 are sealed but are NOT rated for high pressure washing, use caution if power washing near theVSFM-002module.

• Do NOT mount the VSFM-002 directly on top of the engine or near the exhaust manifolds due to heat concerns.

• Do NOT mount the VSFM-002 in the line of site of high temperature objects such as exhaust manifolds, turbinehousings,etc...Ifneeded,installaheatshieldinbetweentheheatsourceandthemoduletoprotecttheplasticcase.

• DoNOTinstallwithin6”ofnitroussolenoidsorotherdeviceswithstrongmagneticfields.

• Do NOT install near the spark plugs or the spark plug wires (or other potential strong sources of electrical noise).

• LPErecommendstheuseofresistortypesparkplugsandRFI(radiofrequencyinterference)andEMI(ElectromagneticInterference)suppressionsparkplugwiresonallEFIenginesandanyvehiclethathaselectroniccontrolmodulesonboard(includingtheVSFM-002).Failuretodosomayresultinerraticoperation of electronic device

Page 11

Table 3: Temperature Sensor Resistance vs. Temperature

Temperature

Temperature sensor type(Sensor Type 1) (Sensor Type 2) (Sensor Type 3) (Sensor Type 4)

GM ECT/IAT/TFT

(DIP Switch 1: DownDIP Switch 2: Down)

AEM / Autometer 1/8 NPT

(DIP Switch 1: DownDIP Switch 2: Up)

GM / AEM / Bosch / Sensata EGT Platinum

RTD (DIP Switch 1: Up

DIP Switch 2: Down)

Bosch IAT/ECT Sensor Group

(DIP Switch 1: UpDIP Switch 2: Up)

°C °F Resistance values measured in Ohms-40 -40 100700 402000 170 45,313-30 -22 52700 210000 178 26114-20 -4 28680 114000 185 15462-10 14 16180 64300 193 93970 32 9420 37500 201 5896

10 50 5670 22500 208 379220 68 3520 14000 216 250030 86 2238 8900 224 170740 104 1459 5800 231 117550 122 973 3900 239 83460 140 667 2700 246 59670 158 467 1900 254 43680 176 332 1300 261 32390 194 241 965 268 243

100 212 177 710 276 187110 230 132 531 284 144120 248 100 403 291 113130 266 77 309 299 89140 284 60 241 306 71150 302 47 189 313 57200 392 - - 349 -300 572 - - 420 -400 752 - - 488 -500 932 - - 554 -600 1112 - - 618 -700 1292 - - 679 -800 1472 - - 738 -900 1652 - - 795 -

1000 1832 - - 849 -

• Allresistancevaluesshownaboveareapproximateandwillbedifferentbasedonwhichspecifictemperaturesensoryou use. Also keep in mind that most of these sensors are rated to within +/- 3% to 5% variation from sensor to sensor so the above tables are not exact.

Des

crip

tion

Sen

sor

Type

(Tab

le 3

)M

ake

PN

Alte

rnat

eP

NTh

read

Siz

eM

atin

gC

onne

ctor

Term

inal

sG

M

Ser

vice

H

arne

ss

AC

Del

co

Ser

vice

H

arne

ssD

iffer

entia

l Tem

p. S

enso

rTy

pe 1

GM

2083

7545

N/A

M12

x 1

.515

4490

2815

3262

6688

9879

93P

T179

8D

iffer

entia

l Oil

Coo

ler

Tem

p. S

enso

rTy

pe 1

GM

2090

7436

N/A

M12

x 1

.5

Man

ual T

FT S

enso

rTy

pe 1

GM

1245

8118

N/A

M21

x 1

.75

1544

9028

1532

6266

8898

7993

PT1

798

EC

T S

enso

rTy

pe 1

GM

1260

8814

213-

4333

M12

x 1

.515

4490

2815

3262

6688

9879

93P

T179

8

IAT

Sen

sor,

fast

resp

onse

Type

1G

M12

6147

1721

3-44

05M

14 x

1.5

tape

r pi

pe12

1621

9712

0892

9012

1026

20P

T307

IAT

Sen

sor,

fast

resp

onse

Type

1G

M12

1602

4421

3-24

3P

ress

-in 1

4 m

m12

1621

9712

0892

9012

1026

20P

T307

Am

bien

t Air

Tem

p. S

enso

rTy

pe 1

GM

1593

6931

213-

4190

Pre

ss-in

1205

2641

1204

8074

1210

1856

PT2

48E

CT

Sen

sor

Type

1G

M12

1463

1221

3-92

83/

8” -

18 N

PTF

1544

9028

1532

6266

8898

7993

PT1

798

EC

T S

enso

rTy

pe 1

GM

1532

6388

213-

953

M12

x 1

.515

4490

2815

3262

6688

9879

93P

T179

8E

CT

Sen

sor

Type

1G

M17

9513

8N

/A15

4490

2815

3262

6688

9879

93P

T179

8E

CT

Sen

sor

Type

1G

M19

2449

5N

/A15

4490

2815

3262

6688

9879

93P

T179

8IA

T S

enso

rTy

pe 1

GM

1211

0446

N/A

3/8”

- 18

NP

TF12

1621

9712

0892

9012

1026

20P

T307

IAT

Sen

sor

Type

1G

M12

1468

30N

/A3/

8” -

18 N

PTF

1216

2197

1208

9290

1210

2620

PT3

07IA

T S

enso

r, fa

st re

spon

seTy

pe 1

GM

2503

6751

213-

190

3/8”

- 18

NP

TF12

1621

9712

0892

9012

1026

20P

T307

IAT

Sen

sor,

fast

resp

onse

Type

1G

M25

0372

2521

3-19

03/

8” -

18 N

PTF

1216

2197

1208

9290

1210

2620

PT3

07IA

T S

enso

r, fa

st re

spon

seTy

pe 1

GM

2503

7034

213-

190

3/8”

- 18

NP

TF12

1621

9712

0892

9012

1026

20P

T307

EC

T S

enso

rTy

pe 2

AE

M30

-201

2N

/A1/

8” N

PT

EG

T S

enso

rTy

pe 3

AE

M30

-205

0N

/AM

14 x

6H

EG

T S

enso

rTy

pe 3

GM

1263

6612

213-

4695

M14

x 1

.513

5100

9915

3262

6888

9878

60P

T170

3E

GT/

RTD

Sen

sor

Type

3B

osch

1075

4551

947

PT

200E

M14

x 1

.5F

02U

000

229

-01

EG

T/ R

TD S

enso

rTy

pe 3

GE

920-

569A

-LR

N/A

M14

x 1

.5A

MP

2820

80-1

AM

P 28

2403

-1E

GT/

RTD

Sen

sor

Type

3S

ensa

taTS

200-

AN

/AE

GT/

RTD

Sen

sor

Type

3S

ensa

taTS

200-

CN

/AR

TD S

enso

rTy

pe 3

Sen

sata

TS20

0-F

N/A

RTD

Sen

sor

Type

3S

ensa

taTS

200-

GN

/AIA

T S

enso

rTy

pe 4

Bos

ch27

8007

1435

N/A

Pre

ss-in

18

mm

D 2

61 2

05 3

36-0

1IA

T S

enso

rTy

pe 4

Bos

ch27

8265

0379

N/A

M12

x1.5

D 2

61 2

05 2

88-0

1IA

T S

enso

rTy

pe 4

Bos

ch02

8013

0039

N/A

M12

x1/5

D 2

61 2

05 2

88-0

1E

CT

Sen

sor

Type

4B

osch

2782

5697

39N

/AM

12x1

.5D

261

205

288

-01

EC

T S

enso

rTy

pe 4

Bos

ch27

8261

0059

N/A

M12

x1.5

D 2

61 2

05 2

88-0

1

Tabl

e 4:

Com

mon

IAT,

EC

T &

Oth

er F

luid

Tem

pera

ture

Sen

sors

Page 12

Page 13

Using the VSFM-002 to activate one or two fans or pumps based on ECT sensor output

Usingthewiringdiagrambelow,thespeedofthefan(s)isbasedoffoftemperature.Thefan(s)willturnonwhentheECTsensorreadsatemperatureequaltothe“Starttemp.”Thefan(s)willrunatmaximumspeedwhentheECTsensorreadsatemperatureequaltoorgreaterthan“MaxOutputTemp.”(Thereisalinearrelationshipbetweenfanspeedandthe“StartTemp”/”MaxOutputTemp”window).Ifusingamanualoverrideswitch,agroundsignalissenttothe“OverrideInput”whentheoverrideswitchisactivated.Thiswillcausethefan(s)torunatmaximumspeed.Whenthefan/pumpisoperatingatmaximumspeed“RelayOutput”isactive.“RelayOutput”canbeconnectedtoanLEDwarninglightoranauxiliarycoolingfan.

To switched and fused 12v power

To switched and fused 12v power

To Ground

To Ground

ECT Sensor

OptionalFan #2 (or pump)

Fan #1 (or pump)

To Ground

To Ground

Power

VSFM-002Temperature BasedPWM Ouput Module

Ground - Black

Relay Output - GrayPWM Out, Ground - Yellow

x100

x10

+12V Switched Power - Red

Start Temp (Deg F)

x10x100

Max Output Temp (Deg F)

Sensor Signal - Purple

PWM Out,+12V - Orange

Override Input - White

Analog Out Signal - Blue

Sensor Ground - Brown

Device Select

To fused 12v power*

To fused 12v power*

To PWM IN

OptionalManual Override

Switch

OptionalLED Warning

Light or Auxiliary Fan Relay

*Some Brushless PWM controlled fans/pumps may require a switched power source. Without a switched power source, the fan/pump may run at full speed or drain the battery when a pwm signal is not present (e.g. VSFM-002 is powered o�). Other fans/pump do not require a switched power source, and will go into a low power mode when a pwm signal is not

present. Check your fan/pump documentation to determine if your fan/pump requires a switched power source.

Page 14

APPENDIX AAdvanced Settings:The advanced settings affect the Temperature Controlled PWM mode and the User Controlled Fan/Pump Speed %Mode.

When DIP switch #4 and #5 ARE NOT positioned in the same direction, the Override Input logic is reversed.

• Insteadofthefan/pumpoperatingatmaxspeed(TemperatureControlledPWMMode)orInputActivationSpeed%(UserControlledFan/PumpSpeed%Mode)whenthereisanOverrideInputActivation signal present, the fan/pump will operate at full speed or Input Activation % when an OverrideInputActivationsignalisnotpresent.

• Thetablesbelowshowthecorrespondingoutputsdependingonthedifferentinputcombinations.

TemperatureControlledPWMmode(Page8):

Input Output

Activation PolarityDIP Switch Override

Input PresentFan/Pump

Speed LED#4 #5

+12V Activation

NO Normal Operation

YES Max Speed Blinking RED/GREEN

NO Max Speed BlinkingRED/GREEN

YES Normal Operation

Ground Activation

NO Normal Operation

YES Max Speed BlinkingRED/GREEN

NO Max Speed BlinkingRED/GREEN

YES Normal OperationUserControlledFan/PumpSpeed%Mode(Page9):

• (Speed1%)refersto(StartingSpeed%),and(Speed2%)refersto(InputActivationSpeed%).

Input Output

Activation PolarityDIP Switch Override

Input PresentFan/Pump

Speed LED#4 #5

+12V Activation

NO Speed1 % GREENYES Speed2 % REDNO Speed2 % REDYES Speed1 % GREEN

Ground Activation

NO Speed1 % GREENYES Speed2 % REDNO Speed2 % REDYES Speed1 % GREEN

Page 15

APPENDIX BSPAL Control Strategy:SPALhastwodifferentcontrolstrategies.IfyoudonotknowwhichSPALfan“DeviceSelect”option(page7)tochoose,checkthefanmotoronthebacksideofthefan.

NOTE: SPALspecifiesthatadeviceusingaSPALcontrolstrategytocontrolacorrespondingSPALfanwillnotvoidthefactorywarranty.TheLingenfelterPerformanceEngineeringVSFM-002conformstoSPAL’scontrolstrategies.

PLUSSERIES-Choose“DeviceSelect”1 NONPLUSSERIES-Choose“DeviceSelect”0

Page 16

Limited Warranty:LPE warrants the Lingenfelter VSFM-002 Variable Speed Fan & Pump Controller be free from defects in material and workmanshipundernormaluseandifproperlyinstalledforaperiodofoneyearfromthedateofpurchase.Ifthemoduleis found to be defective as mentioned above, it will be replaced or repaired if returned prepaid along with proof of date ofpurchase.ThisshallconstitutethesoleremedyofthepurchaserandthesoleliabilityofLPE.Totheextentpermittedby law, the foregoing is exclusive and in lieu of all other warranties or representations whether expressed or implied, includinganyimpliedwarrantyofmerchantabilityorfitness.InnoeventshallLPEbeliableforspecialorconsequentialdamages.

Troubleshooting:If you believe your device is not operating at the correct speed, check the following:

• Verifythatyouhaveselectedthecorrectdevice(Table2,page7).

• Verifythatyouhaveselectedthecorrecttemperaturesensor(Table3and4,pages11and12).

• VerifythattheVSFM-002isoperatinginthecorrectmode(DIPswitch#3,pages8and9).

If the Override Input is not working correctly, check the following:

• VerifythattheOverrideInputsignalisnotactivatedwhentheVSFM-002ispoweredon.

• VerifythatyouareyouusingthecorrectOverrideInputsignal(DIPswitch#5,page5).

NOTICES:It is the responsibility of the purchaser to follow all guidelines and safety procedures supplied with this product and any othermanufacture’sproductusedwiththisproduct.

Lingenfelter Performance Engineering assumes no responsibility for damages resulting from accident, improper installation, misuse, abuse, improper operation, lack of reasonable care, or all previously stated reasons due to incompatibilitywithothermanufacturer’sproducts.

Lingenfelter Performance Engineering assumes no responsibility or liability for damages incurred from the use of products manufacturedorsoldbyLingenfelterPerformanceEngineeringonvehiclesusedforcompetitionracing.

It is the purchaser’s responsibility to check the state and local laws and sanctioning body requirements pertaining to the useofthisproductforracingapplications.LingenfelterPerformanceEngineeringdoesnotrecommendnorcondonetheuseofitsproductsforillegalstreetracing.

For additional product installation information and technical support, contact LPE or your LPE products distributor.Youcanalsofindtechnicalsupportandusagediscussionsregardingthisproductandmanyother LPE products in our Internet forums:

http://www.lingenfelter.com/forum_lingenfelter/index.php

Follow us on Facebook!

http://www.facebook.com/home.php#!/lpehp

L460320002 VSFM-002 Variable Speed Fan & Pump Controller v1.8.indd

Lingenfelter Performance Engineering1557 Winchester Road

Decatur, IN 46733(260) 724-2552

(260) 724-8761 faxwww.lingenfelter.com