Upload
nguyenanh
View
217
Download
2
Embed Size (px)
Citation preview
9415
14
80
S
W 3
rd
S
TR
EE
T, S
UIT
E 9
PO
MP
AN
O B
CH
, F
L 3
30
69
Sta
te
L
ic.#
E
F 0
00
00
84 F
IR
E &
S
EC
UR
IT
Y S
YS
TE
MS
, IN
C.
FA
X =
> 9
54
.7
85
.7
80
4
ww
w.b
assu
nite
d.co
m
TO
LL
F
RE
E =
> 1
.8
00
.3
72
.2
77
0
95
4.7
85
.7
80
0
24
H
ou
r E
me
rg
en
cy S
ervice
UN
IT
ED
CE
RT
. N
o. 97377
LE
VE
L IV
BR
AD
H
IG
DO
N
N I C
E
T
R
CHAU
VET
OFFI
CE52
00 N
W 1
08TH
AVE
NUE
SUNR
ISE,
FLO
RIDA
333
51AC
CESS
CON
TROL
SYS
TEM
5 SCALE: NTSRISER DIAGRAM
3 SCALE:NTSSEQUENCE OF OPERATION 3 SCALE:NTS
FACP BATTERY CALCULATIONS
SCOPEOF WORK
AREA OFWORK
SCOPEOF WORK
FA-01KEY PLAN
2 SCALE: 1/8"=1'AREA OF WORK- FIRE ALARM PLAN
SYMBOL LEGENDSYMBOL QTY DESCRIPTION
EXFIRE LITE MS-9200UDLS FIRE ALARM CONTROLPANEL - EXISTING
EX FIRE LITE ANNUNCIATOR - EXISTING
EXFIRE LITE BG-12L MANUAL PULL STATION -EXISTING
EXFIRE LITE SD355 ADDRESSABLE PHOTOELECTRICDETECTOR - EXISTING
EX FIRE LITE H355 HEAT DETECTOR - EXISTING
1 FIRE-LITE RELAY MODULE CRF-300
E DENOTES EXISTING TO REMAIN DEVICES
R DENOTES DEVICES BIENG RELOCATED AS SHOWN ONPLAN
NDENOTES NEW DEVICES BEING ADDED IN NEWLOCATIONS
E
E
P E
R N
WIRE LEGENDTYPE DESCRIPTION SIZE
# OFCONDUCTORS
NOTES
Z2
16 AWG FPL, FPLP, THHNUNSHIELDED
16 AWG 2 SLC CKT
P2
14 AWG FPL, FPLP, THHNUNSHIELDED
14 AWG 2 24V POWER
G THHN * 14 AWG 1 GROUND
* ALL WIRING INSTALLATION SHALL BE IN COMPLIANCE WITH NFPA 72, LIFESAFETY CODE 101, & N.E.C. (CURRENT EDITIONS)
* CONNECTIONS AT DEVICES SHALL BE AS INDICATED ON INSTALLATIONDOCUMENTS & AS FURNISHED WITH EQUIPMENT &/OR DEVICES.
* ALL FIRE ALARM WIRING SHALL BE POWER LIMITTED
* CABLE SIZE SHALL COMPLY WITH N.E.C. ARTTICLE 760.71
LINETYPE LEGENDLINE TYPE LETTER DESCRIPTION
Z SIGNALING LINE CIRCUIT (SLC)
P 24VDC POWER
SCOPE OF WORKBass United Fire and Security, Inc. (we, us, our) will furnish and install a newrelay for door release to an existing Fire Alarm system on an existing office andwarehouse building, as shown herein in order to provide appropriate minimumrequirements for performance, selection, use, and location of detection andnotification devices to ensure timely warning for the purposes of life safety andprotection.
Our scope of work includes installation, parts, materials, programming, testing,and certification of the system consisting of:
FireLite relay module
All the work will be done in compliance with: FFPC - 2010 ed.NFPA 101 - 2009 ed.NFPA 72 - 2002 ed.NFPA 70/NEC - 2005 ed. FFBC - 2007 ed. ALL LOCAL PREVAILING CODES
5 SCALE:NTSRELAY DETAILS
1 SCALE:NTSLOCATION MAP
9'-6"2 62,275