69.50
240.00
69.5
240
Maintaining all of the features that made the fluorescent system such a success, LED technology can now be incorporated into our Pro-Flite system.
Pro-Flite can be manufactured in individual or continuous fittings to allow tailored solutions to suit clients own requirements.
Direct only, direct/indirect and infill panels for emergency lighting, sensors or track sections are available. Adding in the multiple mounting options – suspended, ceiling surface mounted or wall mounted – Pro-Flite is an incredibly versatile system.
• Latest LED technology can give luminaire efficiencies up to 120 ll/cw.• Individual or continuous mounting.• Colour rendering index Ra >80.• Predicted lifetime >50,000 hours.• Colour temperature – available in 3000K and 4000K versions.• Through wiring supplied to continuous versions to ensure quick
and easy installation on site.• Flexible system with direct only, direct/indirect and indirect
only options available.• Aluminium extruded body allows for flexible infill lengths
allowing total run lengths to suit any installation.• Infill sections can incorporate sensors, emergency LEDs and track sections amongst others.• Corner, T and X pieces can be manufactured to 90° as standard. Special angles available on request.• Standard ITAB Prolight LED warranty (see page 193).
PRO-FLITE LED
70
Tel: +44 (0)1442 419155 · www.itabl ight ing.co.ukLighting Systems – Pro-Flite
PlanningPro-Flite can be individually or continuously mounted. Catalogue numbers shown are for the individually mounted luminaires. Overall dimensions shown are the minimum required for each option. For specification of continuous system please provide a rough dimensioned layout, mounting details, lumen output requirements (if known) and required positions and any track/downlight positions. We will then provide a drawing with the complete product specification.
EmergencyIntegral maintained 3 hour emergency packs can be supplied for all LED lit sections. Also available are Emergency LED downlights which can be built into infill sections on continuous runs. All of these can be manual test, self test or DALI reporting.
Wiring/ControlsA plug and socket through wiring facility is supplied for up to 4 way mains wiring in 1.5mm2 cable as standard. Multiple switched circuits, dimming and PIR/Photocell controls can be incorporated. Our technical depart ment will be pleased to provide full layout drawings and product specifications.
Direct Direct/Indirect Direct/Indirect IndirectDirectDirectDirect Direct/Indirect
Typical WeightsInfill – 4.5 Kg/m LED Section – 4Kg/m
Indirect
Suspended Suspended Wall Mounted Wall MountedWall MountedCeiling SurfaceSurface SurfaceSuspended
71
Tel: +44 (0)1442 419155 · www.itabl ight ing.co.ukLighting Systems – Pro-Flite
Catalogue No.
LED Flux
(Lumens)
Luminaire Flux
(Lumens)LED
Wattage
Total System
Wattage
Luminaire Lumens /
Circuit Watt
Colour Temp CRI
Approx T5 Equivalent
Length (mm)
PRFL/14/F/60/3K 6000 4860 38.4 44.2 110 3000K >80 2x28W 1400PRFL/17/F/75/3K 7500 6075 48.0 55.2 110 3000K >80 2x35W 1700PRFL/17/F/100/3K 10000 8100 62.0 71.3 114 3000K >80 2x49W 1700
PRFL/14/F/60/4K 6000 4860 35.9 41.3 118 4000K >80 2x28W 1400PRFL/17/F/75/4K 7500 6075 44.9 51.6 118 4000K >80 2x35W 1700PRFL/17/F/100/4K 10000 8100 58.3 67.0 121 4000K >80 2x49W 1700
OPTIONSControl Gear: Fixed output as standard, DALI, DSI, Switchdim versions available on request.Dimmable To specify DALI driver, replace ‘F’ in the catalogue number with ‘X’:Drivers: e.g. PRFL/14/X/60/3K
To specify DALI driver wired for Switchdim operation, replace ‘F’ in the catalogue number with ‘S’: e.g. PRFL/14/S/75/4K
Emergency: To specify 3 hour maintained emergency packs, add ‘E’ to catalogue number: e.g. PRFL/14/F/60E/3K To specify 3 hour self test emergency packs, add ‘ES’ to catalogue number: e.g. PRFL/14/F/60ES/3K To specify 3 hour DALI test emergency packs, add ‘ED’ to catalogue number: e.g. PRFL/14/F/60ED/3K. Separate LED emergency downlight available to mount in infill bodies in continuous system.
Mounting: Wire suspended, ceiling surface mounted, wall mounted, rod suspended.
LEDPRFL
• Predicted lifetime >50,000 hours.
• Standard ITAB Prolight LED warranty (see page 193). Direct
72
Tel: +44 (0)1442 419155 · www.itabl ight ing.co.ukLighting Systems – Pro-Flite
Catalogue No.
LED Flux
(Lumens)
Luminaire Flux
(Lumens)LED
Wattage
Total System
Wattage
Luminaire Lumens /
Circuit Watt
Colour Temp CRI
Approx T5 Equivalent
Length (mm)
PRFLI/14/F/60/3K 6000 4392 38.4 44.2 99 3000K >80 2x28W 1400PRFLI/17/F/75/3K 7500 5490 48.0 55.2 99 3000K >80 2x35W 1700PRFLI/17/F/100/3K 10000 7320 62.0 71.3 103 3000K >80 2x49W 1700
PRFLI/14/F/60/4K 6000 4392 35.9 41.3 106 4000K >80 2x28W 1400PRFLI/17/F/75/4K 7500 5490 44.9 51.6 106 4000K >80 2x35W 1700PRFLI/17/F/100/4K 10000 7320 58.3 67.0 109 4000K >80 2x49W 1700
Upward Prismatic Polycarbonate Diffuser• Prismatic polycarbonate snap-in diffuser with wide distribution.
• Approximately 80% downward/ 20% upward light.
• Predicted lifetime >50,000 hours.
• Colour temperature – available in 3000K and 4000K versions.
• Standard ITAB Prolight LED warranty (see page 193).
OPTIONSControl Gear: Fixed output as standard, DALI, DSI, Switchdim versions
available on request.Dimmable To specify DALI driver, replace ‘F’ in the catalogue number with ‘X’:Drivers: e.g. PRFLI/17/X/60/3K
To specify DALI driver wired for Switchdim operation, replace ‘F’ in the catalogue number with ‘S’: e.g. PRFLI/17/S/75/4K
Emergency: To specify 3 hour maintained emergency packs, add ‘E’ to catalogue number: e.g. PRFLI/17/F/75E/3K To specify 3 hour self test emergency packs, add ‘ES’ to catalogue number: e.g. PRFLI/17/F/75ES/3K To specify 3 hour DALI test emergency packs, add ‘ED’ to catalogue number: e.g. PRFLI/17/F/75ED/3K. Separate LED emergency downlight available to mount in infill bodies in continuous system.
Mounting: Wire suspended, ceiling surface mounted, wall mounted, rod suspended.
LEDPRFLI
Direct/Indirect
73
Tel: +44 (0)1442 419155 · www.itabl ight ing.co.ukLighting Systems – Pro-Flite
1700
1400
70
70
35
1580
1280
240
35
76
1700
1400
70
70
35
1580
1280
240
35
76
1700
1400
70
70
35
1580
1280
240
35
76
Catalogue No.
LED Flux
(Lumens)
Luminaire Flux
(Lumens)LED
Wattage
Total System
Wattage
Luminaire Lumens /
Circuit Watt
Colour Temp CRI
Approx T5 Equivalent
PRFLS/14/F/60/3K 6000 4860 38.4 44.2 110 3000K >80 2x28W PRFLS/17/F/75/3K 7500 6075 48.0 55.2 110 3000K >80 2x35W PRFLS/17/F/100/3K 10000 8100 62.0 71.3 114 3000K >80 2x49W
PRFLS/14/F/60/4K 6000 4860 35.9 41.3 118 4000K >80 2x28W PRFLS/17/F/75/4K 7500 6075 44.9 51.6 118 4000K >80 2x35W PRFLS/17/F/100/4K 10000 8100 58.3 67.0 121 4000K >80 2x49W
240
76
1700
5 board version
1580
35
∅ 20mm cable entry
Fixing centre details for 4 / 5 board version
35
1400
4 board version
1280
70
70 ∅ 20mm cable entry
LEDPRFLS
OPTIONSControl Gear: Fixed output as standard, DALI, DSI, Switchdim versions available on request.Dimmable To specify DALI driver, replace ‘F’ in the catalogue number with ‘X’:Drivers: e.g. PRFLS/14/X/60/3K
To specify DALI driver wired for Switchdim operation, replace ‘F’ in the catalogue number with ‘S’: e.g. PRFLS/14/S/75/4K
Emergency: To specify 3 hour maintained emergency packs, add ‘E’ to catalogue number: e.g. PRFLS/17/F/75E/3K To specify 3 hour self test emergency packs, add ‘ES’ to catalogue number: e.g. PRFLS/17/F/75ES/3K To specify 3 hour DALI test emergency packs, add ‘ED’ to catalogue number: e.g. PRFLS/17/F/75ED/3K Separate LED emergency downlight available to mount in infill bodies in continuous system.
• Predicted lifetime >50,000 hours.
• Standard ITAB Prolight LED warranty (see page 193).
74
Tel: +44 (0)1442 419155 · www.itabl ight ing.co.ukLighting Systems – Pro-Flite
Solid Joints• Standard solid bends available.
• Special angles available on request.
Adjustable Steel Wire Suspension• Simple length and balance adjustability.
• Supplied with chrome ceiling fixing barrel.
• Optional plate and cone covers are available.
• Coiled cables supplied on request to suit application.
Type Catalogue No.
90° Joint PRF/SB90T-Joint PRF/SBTCross Joint PRF/SBX
Length (mm) Catalogue No.
350 PRF/AB
Depth (mm) Catalogue No.
90 PRF/STAND OFF BRKT
Length (mm) Catalogue No.
500 SUSKIT/0.5M/2-Y1000 SUSKIT/1.0M/2-Y2000 SUSKIT/2.0M/2-Y3000 SUSKIT/3.0M/2-Y
Threaded M6
Ceiling Attachment
M4 Counter Sunk Machine Screw, or No. 8 Counter Sunk Wood Screw
Threaded Cap
Pressed Nipple on end of Suspension Wire
350
100
100
100
100
240
100
240
240
100
100
100
Adjustable Bend• 25mm diameter PVC flexible conduit for connecting
luminaires at different angles and levels.
ACCESSORIES
Surface Stand Off Bracket (SB)• Surface bracket to provide indirect lighting in
surface mounted installations.
• Supplied as pair for one luminaire.
90
76
Tel: +44 (0)1442 419155 · www.itabl ight ing.co.ukLighting Systems – Pro-Flite
Wall Mounting Brackets• Available for individual and continuous mounting.
End Wall Mount Bracket• For wall to wall mounting of Pro-Flite. Suitable for power feed
from wall.
Optional Catalogue No.
White ceiling suspension cover plate SUS/CCPWWhite ceiling cover cone SUS/SCCW
Description Catalogue No.
End of run PRF/WMBEIntermediate PRF/WMBT
Description Catalogue No.
End of wall bracket PRF/END WALL BRKT
260
280260
3
Protrusion from wall 100mm
White Ceiling Cover Plate
White Ceiling Cover Cone
White Ceiling Cover Cone with supply cable
6060
9090
51
6
∅70mm
2 holes∅6mm
Optional Suspension Accessories
77
Tel: +44 (0)1442 419155 · www.itabl ight ing.co.ukLighting Systems – Pro-Flite