Lift Station Safety and Maintenance. Tony Conn, Supervisor Wastewater Collection and Pumping [email protected]. Safety. Lock out Tag out Confined Space Working on Energized Electrical Equipment Arc Flash Fall Protection Crane Safety and Inspections Tail Gate Talks. - PowerPoint PPT Presentation
Citation preview
Lift Station Safety and Lift Station Safety and Maintenance Maintenance
Tony Conn, Supervisor Wastewater Collection and [email protected]
SafetySafetyLock out Tag outConfined SpaceWorking on Energized Electrical Equipment
Arc FlashFall ProtectionCrane Safety and InspectionsTail Gate Talks
SafetySafety
Lock-out/Tagout Confined Space
SafetySafety
Energized Equipment Arc Flash
Electric PermitElectric Permit
SafetySafety
Fall Protection Fall Protection
SafetySafety
Fall Protection Fall Protection
Crane Safety/InspectionCrane Safety/Inspection
Over Head Crane Truck Crane
Crane Inspection FormCrane Inspection FormCity of Naperville
DPU-W Collection and Pumping
Crane Inspection Form Date_____________ Type of Equipment______________________________ Location_______________________________________ Inspected By___________________________________ Indicate By “Yes” if item checked is adequate, operational and safe. Initial “No” to indicate repair or other action is required. Use “N\A” to indicate not applicable.
Items to be Checked Yes No N\A A. Load Line: lubricated, wound properly on drum, condition of line B. Whip Line: lubricated, wound properly on drum, condition of line C. Hook and safety latches on load block. D. Hook and safety latches on headache ball E. Cable at wear points F. Pins in becket G. Wedges installed H. Clamps on dead ends I. Boom pins J. Cotter pins K. Controls: Check operation in all motions L. Condition of remote control both hard wired and wireless M. Check elec. breakers and all switches. N. Check oil level in unit. O. Test run cable all the up and return. Look for any cable defects P. Does over head cranes move freely Q. Do swing cranes move freely R. Check all Fall Protection be use of any crane. Comments:_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Use all PPE at all times, Inspected PPE before and after every use. Report any defects to your Supervisor. Form to be filled out before the use of any crane.
MaintenanceMaintenance4 - Wastewater Pumping Stations7 - Back Flow Prevention Stations19 - Lift Stations2 - Person Maintenance Crew1- Field Supervisor10,000 lb Crane Truck¾ ton Utility truck with external
fuel tank and snow plow2 -other crew members trained in
safety and basic maintenance
MaintenanceMaintenance
• Monthly visual inspection
• Semi- annual maintenance
• General maintenance
Maintenance Maintenance TrainingTraining
Maintenance crew certification on fluke test equipment
Hands on training at Joliet Junior College
ElectricalMotor and pumpsVFD’SMotor controlsPLC’S
MaintenanceMaintenancePumpsMixerCheck valvesWet wellsAir valvesControl panelsBuilding and groundsBlower/venting systemsOdor controlMinimal generator maintenanceDon’t work on SCADA
Pump MaintenancePump Maintenance
Mixers and Flush ValvesMixers and Flush Valves
Air ValvesAir Valves
Check Valve Check Valve ReplacementReplacement
Truck Mounted Truck Mounted ComputersComputers
EMERGENCY PROCEDURESEMERGENCY PROCEDURES Emergency Procedures for Power Outage and Bypass Pumping
Monarch Landings Sanitary Lift Station
Location: Corporate Drive
Sub: Monarch Landing Senior Village
Power Outage to lift station:
Once outage is detected, standby generator will provide 25 KVA of power, supplied by Olympian generator located on site. Generator if fueled by natural gas.
Power outage can be monitored remotely by city Wastewater S.C.A.D.A. system located on City’s Citrix website.
Bypass Pumping:
If emergency generator is unable to provide power to the station. Then bypass pumping becomes 2nd options.
Then following procedure is to take place:
Make sure all employees have their PPE on them (Hard hat, safety glasses, safety boots, safety vest, gloves, and confine space gear, to perform the following task.
Quickly inspect 4” pump for the following items. 4” gaskets on connecting side of the suction and discharge side of hoses. 4” pump has be topped off with fuel. No sign of any leaks regarding fuel, oil, or antifreeze.
Make sure pump is primed before starting the pump at the station.
Open both lift station gates, and back the pump inside the fence area.
Position 4” pump so towing tongue of pump is facing EAST Discharge would be facing NORTH. Suction would be facing WEST
Place both pumps in the off position inside the control cabinet.
Pull all floats, level transducer out of the wet well. Make sure floats are not tilted.
Put three 4” rigid suction hoses into the wet well just above the pumps. (Make sure you DO NOT drop hose onto pump head or electric head cord.)
Make sure all quick couplings are latched and secured to prevent accidental disconnect from the hoses. If needed use duct tape or wire-ties to prevent accidental disconnect.
Connect one 4” discharge hose and laid it to the manhole just to the north of the station.
(Basin N01-056 manhole is painted red) Just outside of the northeast fence line.
Start 4” pump to pump down wet well. Continue to monitor wet well levels and slow pump down to prevent lose of suction.
When power is restored, pump wet well level down as far as you can go.
Turn off your 4” bypass pump.
Manual run both pumps to insure everything is fine and running normal with the station prior to removing bypass setup.
Place floats and level transducer back into wet well
Test run station under load and make sure station is pumping and pumps are alternating.
Remove all bypass equipment.
Contact Field Supervisor and Springbrook once everything is running normal.
Using Vactor to remove sanitary wastewater from wet well
When both above procedures are not an option then use Vactors #779 & #777:
Make sure all employees have their PPE on them (Hard hat, safety glasses, safety boots, safety vest, and gloves to perform the following task.
Open lift station gates as wide as possible.
Open doors and secure them in the locked position.
Pull all floats, level transducer out of the wet well. Make sure floats are not tilted; they will active alarms at the station and Springbrook.
Pull Vactor into station with front of truck entering driveway first.
Position Vactor suction hose over wet well doors.
Connect about 3 to 4 8” tubes together. (USE CLAMPS TO CONNECT TUBES TOGETHER, PLUS USE DUCT TAPE TO SECURE CLAMPS FROM COMING APART)
As water level drops you’ll need to add more tubes. Please follow same instruction as G (see above) when installing addition tubes.
Engage Vactor to start vac.ing water from wetwell (Stay above water approximately 3 inches to prevent suction from clogging with water. This will stop removing water from wetwell.)
Once Vactor tank is full you’ll need to dump water into sanitary manhole which will not drain back into wet well. (Basin N01-056 manhole is painted red) Just outside of the northeast fence line.
Once level is normal and station is back on line, place floats, level transducer back into wet well, monitor station for correct operation.
Contact Springbrook and Field Supervisor.
EMERGENCY PROCEDURESEMERGENCY PROCEDURES
Monthly visual inspectionMonthly visual inspection
Semi- annual Semi- annual maintenancemaintenance
Going For a SwimGoing For a Swim
QuestionsQuestions