Upload
others
View
12
Download
0
Embed Size (px)
Citation preview
LIEBHERRR984
Lighting Design Simulation Report
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
SIMULATIONLIEBHERR R984OPTION A
LIEBHERR R984 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 2
Model No. Luminaire Optic Type QuantityCP9-L25 CP9-60 Flood Light L25 - 50° Beam Angle 8
LUMINAIRE SCHEDULELIEBHERR R984OPTION A
MODEL CP9OPTIC L25
ANGLE 20°DIRECTION 270°
MODEL CP9OPTIC L25
ANGLE 20°DIRECTION 0°
MODEL CP9OPTIC L25
ANGLE 20°DIRECTION 0°
MODEL CP9OPTIC L25
ANGLE 45°DIRECTION 0°
MODEL CP9OPTIC L25
ANGLE 15°DIRECTION 210°
MODEL CP9OPTIC L25
ANGLE 15°DIRECTION 150°
MODEL CP9OPTIC L25
ANGLE 15°DIRECTION 90°
MODEL CP9OPTIC L25
ANGLE 45°DIRECTION 0°
LIEBHERR R984 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 3
Total LLF: 0.7
ISOLINE VIEWLIEBHERR R984OPTION A
-70
-60
-50
-40
-30
-20
-10
20
30
40
50
60
70
0m
10
10050
50
50
25
25
25
25
25
10
10 10
10
10
10
10
10
5
5
5
5
5
5
5
5
5
1
1
1
1
1
LIEBHERR R984 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 4
OPERATOR’S VIEWLIEBHERR R984OPTION A
LIEBHERR R984 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 5
SIMULATIONLIEBHERR R984OPTION B
LIEBHERR R984 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 6
Model No. Luminaire Optic Type QuantityCP24-O209 CP24 Flood Light O209 - 40° x 18° Beam Angle 1
CP24-L25 CP24 Flood Light L25 - 50° Beam Angle 8
LUMINAIRE SCHEDULELIEBHERR R984OPTION B
MODEL CP24OPTIC L25
ANGLE 20°DIRECTION 330°
MODEL CP24OPTIC L25
ANGLE 20°DIRECTION 270°
MODEL CP24OPTIC L25
ANGLE 45°DIRECTION 0°
MODEL CP24OPTIC L25
ANGLE 20°DIRECTION 0°
MODEL CP24OPTIC O209
ANGLE 10°DIRECTION 0°
MODEL CP24OPTIC L25
ANGLE 15°DIRECTION 210°
MODEL CP24OPTIC L25
ANGLE 15°DIRECTION 150°
MODEL CP56OPTIC L25
ANGLE 15°DIRECTION 90°
MODEL CP56OPTIC L25
ANGLE 45°DIRECTION 0°
LIEBHERR R984 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 7
Total LLF: 0.7
ISOLINE VIEWLIEBHERR R984OPTION B
-70
-60
-50
-40
-30
-20
-10
20
30
40
50
60
70
0m
10
10050
50
50
50
2525
25
25
25
10
10
10
10
10
10
10
10
5
5
5
5
5
5
5
5
5
1
1
1
1
LIEBHERR R984 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 8
OPERATOR’S VIEWLIEBHERR R984OPTION B
LIEBHERR R984 LIGHTING DESIGN SIMULATION REPORT
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Page 9