3
www.yokogawa.com Data Acquisition & Control LF04L52L01-01EN Basic accuracy: 0.1% of Reading Frequency range: DC and 0.5 Hz to 100 kHz Measurement parameters: all AC and DC related power Interfaces: Std. USB and GPIB or RS232 Optional Ethernet Normal & Harmonics measurement: Simultaneous Digital Power Meter WT300 series SMART Choice for Portable paperless recorder Provides a smooth, familiar user experience Enables a scalable data acquisition system Offers a seamless data transfer environment Smart User Interface Smart Architecture Smart Functionality

LF04L52L01-01EN SMART Choice for - Yokogawa Electric · LF04L52L01-01EN Basic accuracy: ... Harmonics measurement: Simultaneous Digital Power Meter ... Excel spreadsheet template

  • Upload
    doannga

  • View
    235

  • Download
    5

Embed Size (px)

Citation preview

Page 1: LF04L52L01-01EN SMART Choice for - Yokogawa Electric · LF04L52L01-01EN Basic accuracy: ... Harmonics measurement: Simultaneous Digital Power Meter ... Excel spreadsheet template

www.yokogawa.com

Subject to change without noticeAll Rights Reserved. Copyright © 2013, by Yokogawa Electric Corporation

Data Acquisition & Control

LF04L52L01-01EN

Basic accuracy: 0.1% of Reading

Frequency range: DC and 0.5 Hz to 100 kHz

Measurement parameters: all AC and DC related power

Interfaces: Std. USB and GPIB or RS232 Optional Ethernet

Normal & Harmonics measurement: Simultaneous

Digital Power MeterWT300 series

SMART Choice forPortable paperless recorder

Provides a smooth, familiar user experience

Enables a scalable data acquisition system

Offers a seamless data transfer environment

Smart User Interface

Smart Architecture

Smart Functionality

Page 2: LF04L52L01-01EN SMART Choice for - Yokogawa Electric · LF04L52L01-01EN Basic accuracy: ... Harmonics measurement: Simultaneous Digital Power Meter ... Excel spreadsheet template

Up to 1200 ch/system

Inverter

Low interference from noisy environment

Result withGX90XA-10

Result withGX90XA-10-T1

For temperature measurement on high frequency apparatus / devices such as inverters or switching devices…

GX90XA-10-T1

Drag

Multi-panel display

Ethernet

Printer supporting the HP-PCL5 language.

Template file

Auto-creation

Excel spreadsheet

Present

Past

Flick

Drag

Search from a calendarSearch from a variety of

summary screens

First in industry : Integration measurement auto ranging functionConventionally, when power meters operate in an integration mode to measure power consumption and standby power, the measuring ranges need to be fixed. However, if the level of the input exceeds the maximum of the selected range, the results will be incorrect and the test will need to be repeated with higher ranges applied.The WT300 series has a high speed automatic ranging capability in integration mode which removes this need to repeat the test and integration is continuous and accurate.This function is not only available for +/- Wh but also for Ah and DC current.

First in class : Auto ranging function available in selected rangesThe auto-range function is used to select/change the range automatically in specific ranges. This results in shorter range changing times and thus quicker and more efficient testing.

MW100100ms/60ch, 10ms/10ch• Up to 360 channels data acquisition system• Wide operating temperature range: -20 to 60 degC• Networking: Web, Email, FTP, SNTP• Open network: Modbus/TCP, Ethernet/IP, DNP3•

Flick or drag even during measurement to scroll data for seamless display of historical trends.All historical trends can be displayed in one screen.

Select from a wide variety of input/output modules. The I/O terminals are detachable and come in M3 screw and clamp-terminal types. The highly flexible design allows you to add or remove modules at any time in the future.

Through a Web browser (Internet Explorer*) you can monitor the GP in real time and change settings. You can easily build a seamless, low-cost remote monitoring system with no additional software.

Real time monitoring screen (trend)Just as on the GP main unit itself, the Web browser lets you divide the display for monitoring on multiple screens, and even create and save your own monitor screens as "Favorites."

10ch EMR module -DCV/TC/DI (RTD not supported) -Min. measurement interval 1sec -Screw terminal only

Printer output functionYou can print out reports and snapshots directly from the GP without going through a PC.

Report creation function For each type of report, you can output to a PDF file according to specifiable formats.

Excel spreadsheet template function Reports can be created automatically using a spreadsheet template created in Excel.Excel compatibility means greatly reduced time and effort spent on reporting.

*Mathematical function option is required.

You can drag the digital display section up, down, left, or right to change its position.

You can divide the display into 2 to 6 sections and assign each to your choice of screen. You can select from 9 forms (of 2 to 6 screens each), and save up to 20 multi-panel configurations.

Easily find data using various displays including calendars and summary screens.

You can draw or hand-write on the waveform area using a stylus (included) or the tip of your finger. You can even select a color and line width.

[Patent pending]Drag the scale to display corresponding digital values.You can insert your own BMP images to customize the scale.

MX10010ms/24ch, 100ms/60ch• Up to 1200 channel data acquisition system• Simple single units connection with MXstandard• Multi-functional multi-unit connection with MXlogger•

Action of Yokogawa’s previous modelInput signal changes

Range change ends

Change available ranges stepwise

Action of WT310/WT330 series

Range change ends Change to selected next rangeImage of Range skip (configuration)

function operation

* According to YOKOGAWA survey by Dec, 2012

WT300 series and WT200 series comparison •

Flexible and Reliable data acquisition system •Smart Interface •

Smart Architecture •

Smart Functionality •

EMR • (Electromagnetic relay) module

Digital Power Meter WT300 series

Data acquisition DAQMASTER series Portable paperless recorder GP series

First in class* •

Web-enabled Data AcquisitionSeamless display of historical trends

Modular construction for expandable input/output

Web applications seamlessly connect the GP and PC systems

Report* and printer output functions

Change the position of digital values

Monitor multiple screens at once on the multi-panel display

Powerful search functions

Write freehand messages

Move the scale to view details

PC-based Real Time Data Acquisition

First in industry* •

Comparison between WT210/230 series and WT310/330 series

WT310/WT332/WT333 WT310HC WT210/WT230DC power measurement accracy 0.1% of reading+0.2% of range 0.3% of reading+0.2% of range 0.3% of reading+0.2% of range

Current range(Crest factor=3)

Direct input5m/10m/20m/50m/100m/200m/

0.5/1/2/5 /10/20[A] (WT310)0.5/1/2/5/10/20[A] (WT332/WT333)

1/2/5/10/20/40[A] 5m/10m/20m/50m/100m/200m/

0.5/1/2/5 /10/20[A] (WT210)0.5/1/2/5/10/20[A] (WT230)

External current input EX1: 2.5//5/10[V]EX2: 50m/100m/200m/500m/1/2[V] (OP.)

EX1: 2.5//5/10[V]EX2: 50m/100m/200m/500m/1/2[V] (OP.)

EX1: 2.5/5/10[V]EX2: 50m/100m/200m[V] (OP.)

Effective input range for voltage & currnet (CF=3) 1% to 130% 1% to 100% (40A range only) 1% to 130%Maximum displaying value for voltage & current (CF=3) 1% to 140% 1% to 110% (40A range only) 1% to140%

0<PF<1Power reading x {power reading error +

(power range / apparent power reading) + tanØ x (influence when PF = 0)} %

Power reading x {power reading error + (power range / apparent power reading) +

tanØ x (influence when PF = 0)} %

Add the power reading x {tanØ x (influence when PF = 0)}%.

Simultaneous measurement of RMS, VotageMEAN & DC Yes *1 Yes *1 No Frequecy measurement 2 channels (voltage and current) 2 channels (voltage and current) selected voltage or current (one)Number of display item 4 items 4 items 3 itemsSampling rate Approximately 100 kS/s Approximately 100 kS/s Approximately 50 kS/sHarmoinc measurement Yes (OP, / G5) Yes (OP, / G5) Yes (OP, / HRM)THD calculation maximum order setting Yes (OP, 1-50th) Yes (OP, 1-50th) NoAuto ranging of integaration Yes Yes No

Communication interface

USB Yes Yes NoGP-IB Yes GP-IB or RS-232 Yes GP-IB or RS-232 Yes (OP) GP-IB or RS-232CRS-232 Yes GP-IB or RS-232 Yes GP-IB or RS-232 Yes (OP) GP-IB or RS-232CEthernet Yes (OP) Yes (OP) No

IEEE stanndard for GP-IB IEEE488.2 IEEE488.2 IEEE488.1 and IEEE488.2Comparetor function No No YesViewer software (setting & data capturing) Free (included) Free (included) Free (download)

*1: Simultaneous, mode independent measurement using the WTViewerFreePlus PC software.*A command compatible mode for the previous WT200 series is prepared. (IEEE488.2 only) In that mode, the WT300 series works identically to a WT200 series except for the Store (and recall operation) and the Compare functions.

Superior points

Changed points

Model Description

GP20 12.1" TFT color LCDMax. 10 modules slots (Max. 100 channels of input)

GP10 5.7" TFT color LCD Max. 3 modules slots (Max. 30 channels of input)

GX90XA(-U2)

SSR scanner type: 3-wire RTD b-terminal commonDC voltage, thermocouple, RTD, DIMax. 100 ms sampling

GX90XA(-T1)

EMR scanner type :Isolated between channelsDC voltage, thermocouple, DIMax. 1 s sampling

GX90XD Open collector type digital input (inputs: 16)

GX90YD Relay contact type digital output (outputs: 6)

NEW

The touch screen works even when you are wearing gloves.

* The GX90YD is only available with M3 screw type terminals.

With the scroll bar, you can seamlessly scroll between past and current trends. When the sampling interval is 1 second, the instrument displays 1 hour's worth of historical trends.

The multi-panel display is supported only by the GP20.

Historical trend screenSummary screens can be sorted by item for faster searching.

Page 3: LF04L52L01-01EN SMART Choice for - Yokogawa Electric · LF04L52L01-01EN Basic accuracy: ... Harmonics measurement: Simultaneous Digital Power Meter ... Excel spreadsheet template

www.yokogawa.com

Subject to change without noticeAll Rights Reserved. Copyright © 2013, by Yokogawa Electric Corporation

SoftwareGP20, GP10 softwareiPad, Android viewerView Trend, digital readout using your favorite mobile devices.

Data files of all the GX/GP models and other supported Yokogawa recorders can be opened by the viewer for display or printing. You can perform statistical computation over an area and export to ASCII, Excel, or other format.

WTViewerFreePlus For WT300 Series (included)The WTViewerFreePlus software can capture measured numeric values, harmonic values and waveform data. The data can be transferred to a PC via a USB, GP-IB/RS-232 or Ethernet communication interface, and it can be displayed* and saved on the PC.

* Waveform display requires /G5 Harmonic option.

- Allows to quickly set up your favorite conditions (In particular, range-skip function (range-configuration setting) and Max. order used for THD calculation)

- Shows all the setting parameters and the status at a glance

Setting Window

Can display items, which are not available on display of WT300 series: multiple numeric measurement parameters, harmonics data of each order, bar graphs, trend graphs and voltage & current waveforms.* Please check the Instruction manual in the CD for more information.

Configuring and Establishing a New Connection between the WT310 and a PC Test Report

Measurement Window

Power Consumption Measurement Software (Free)The Power Consumption Measurement Software together with a WT310 (or another WT series instrument) provides a trustworthy power measurement solutions for testing the standby and off mode power of household products and office equipment.The solution enables testing to be performed according to the IEC62301 Ed1.0 and Ed2.0 standards which specify the use of special algorithms for determining the power stability in the device under test. The software thus gathers all measurement data (voltage/ current/ power/ frequency, total harmonic distortion (THD) , and crest factor (CF) of the AC power supply): harmonic option (/G5) and a low distortion power supply are useful for the test.

GateWTAn interface software component fortransferring data acquired with WT-seriespower meters to DAQLOGGER.

Functions:Can link up to 16 WT series (below models) via GP-IB or RS-232, or Ethernet :WT110, WT110E, WT130, WT200, WT210,WT230, WT1000 series, WT1600, WT2000series, WT500, WT1800 series (WT500/WT1800 series support GP-IB/Ethernet,WT1600 series support all communicationinterfaces, WT300 series supported throughWT210/WT230 command mode and other WTseries support GP-IB/RS-232)

DAQLogger

New ver. R1.02.02 available for download: supports GX10/GP10/GP20 and some improvement

New ver. R1.02.01: supports all data display on trend

Universal viewer

SMARTDAC+ firmware

Lab View driverLabView driver will be available for download from July 2013

Up to 32 Yokogawa instruments , or otherdevices can be connected enabling acquisition of data.Acquired data are assigned serial numberscalled tags, allowing them to be handled in anintegrated fashion.

* Performance may differ depending on number of units and channels.

Data Acquisition Software suite DAQWORX

WT300 series software

NEW

NEW

DAQLOGGER

Monitor server•Data recording and

real-time monitoring•Data transfer to client PCs•Display of names of

connected hosts

Max. 32 instrumentsMax. 1 sec interval*

Data logging and monitoring

DAQLOGGER Client Package

Remote monitors•Real-time monitoring•Redisplay of acquired data•Simultaneous access to a

maximum of 16 clients

•Data logging from clients can be started or stopped

PC server*

Ethernet

Client Client

All data display on trend screen

GP10/GP20 Wi-Fi router Tablet Smart Phone

Data converted to ASCII