16
COMMITMENT & INTEGRITY DRIVE RESULTS Dan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source Area Thermal Remedy for Synergistic Biotic and Abiotic Degradation of a CVOC Plume

Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

COMMITMENT & INTEGRITY DRIVE RESULTS

Dan Bryant, Duff Collins, and Jason HouseWoodard & Curran

Leveraging Warm Water from Source Area Thermal Remedy for Synergistic Biotic and Abiotic Degradation of a CVOC Plume

Page 2: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

OverviewBackground and Approach Thermal remedy in DNAPL source area Downgradient plume extends ~1,600 feet Leverage warm water for enhanced bioremediation Provect-IR – biotic and abiotic reaction mechanismsResults Water temperatures have increased 3-22°C 10x to >100x reduction in plume VOC concentrations One well cluster with insufficient reagent

Page 3: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

Site and BackgroundNJ - Urban / Industrial AreaChlorinated Solvents (TCE, etc.)~1,600-ft Dissolved Plume

DNAPL Source Area(Thermal Remedy)

Proximal Plume Area(Biotic/Abiotic Remedy)

N

Page 4: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

Site and Background

0 400 800 1,200 1,600

20

-20

-40

0

SandBedrock

Silt

Silt

Building Building Fill

Thermal

Elev

ation

(ft)

Distance (ft)

Biotic+AbioticMNA

Page 5: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

Thermal Remedy Effects Warm water transport

downgradient increases: VOC desorption Organic carbon release Microbial activity Abiotic degradation

rates

Leverage these effects to enhance degradation in proximal plume area

ThermalSourceRemedy

N

Page 6: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

Injection Layout

Treatment Zone 1

Treatment Zone 2

Groundwater Flow

MW-33S/D Cluster

MW-29S/D Cluster MW-34S/D Cluster

Treatment Zone 2

Treatment Zone 1MW-15

Page 7: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

Targeted transmissive sand zone, 14-57 ft below grade

Direct-push injection 30% solids slurry 148,500 lbs Provect-IR 325 injection intervals 57 borings

Injection Details

Page 8: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

Temperature Results

1015202530354045

12/11/2017 4/10/2018 8/8/2018 12/6/2018

Temp

eratu

re (°

C)

Date

MW-15

MW-33S

MW-33D

Treatment Zone 1 (Upgradient)

Page 9: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

Temperature Results

Treatment Zone 2 (Downgradient)

1015202530354045

12/11/2017 4/10/2018 8/8/2018 12/6/2018

Temp

eratu

re (°

C)

Date

MW-29SMW-29DMW-34SMW-34D

Page 10: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

VOC Results – Treat Zone 1

1

10

100

1,000

10,000

100,000

1,000,000

7/4/2017 12/31/2017 6/29/2018 12/26/2018

Conc

entra

tion (µg

/L)

Date

TCEcis-DCEVC

HeatingInjection Events

MW-33D

MW-33S and MW-15 historically <100 ug/L

Page 11: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

VOC Results – Treat Zone 2MW-34D

1

10

100

1,000

10,000

7/4/2017 12/31/2017 6/29/2018 12/26/2018

Conc

entra

tion (µg

/L)

Date

TCEcis-DCEVC

HeatingInjection Events

Page 12: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

VOC Results – Treat Zone 2

1

10

100

1,000

10,000

100,000

7/4/2017 12/31/2017 6/29/2018 12/26/2018

Conc

entra

tion (µg

/L)

Date

TCEcis-DCEVC

HeatingInjection Events

MW-29D

Page 13: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

VOC Results – Treat Zone 2

020,00040,00060,00080,000

100,000120,000140,000

7/4/2017 12/31/2017 6/29/2018 12/26/2018

Conc

entra

tion (µg

/L)

Date

TCEcis-DCEVC

HeatingInjection Events

MW-34S

Page 14: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

VOC Results – Treat Zone 2

0

15,000

30,000

45,000

60,000

75,000

90,000

7/4/2017 12/31/2017 6/29/2018 12/26/2018

Conc

entra

tion (µg

/L)

Date

TCEcis-DCEVC

HeatingInjection Events

MW-29S

Page 15: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

Wrap Up Leveraged warm water downgradient from thermal treatment area Utilized Provect-IR, combined biotic and abiotic treatment reagent Direct-push injection in two permeable reactive zones Temperature increases observed but less than expected One well cluster likely has insufficient reagent

TCE decrease 50%, cDCE increase 3x

10x to 100x reductions in other wells Continuing to evaluate semi-annually

Page 16: Leveraging Warm Water from Source Area Thermal …...COMMITMENT &INTEGRITY DRIVE RESULTSDan Bryant, Duff Collins, and Jason House Woodard & Curran Leveraging Warm Water from Source

Thank You!

Contact Information:Dan Bryant: (609) 375-8026 or [email protected] Collins: (781) 613-0270 or [email protected] House: (207) 558-3731 or [email protected]