14
Leuze electronic We reserve the right to make changes • 96_a02e.fm Throughbeam photoelectric sensors with high performance reserve in infrared light Robust metal housing with glass cover, pro- tection class IP 67/IP 69K for industrial application Complementary outputs, sensitivity adjustment and delay before start-up for optimal adaptation to the application Connection via M12 connector or terminal compartment Multiple options with warning output, activation input, switching delays and optics heating for use at low temperatures 150m 10 - 30 V DC A 2 LS Accessories: (available separately) Mounting systems (BT 96, BT 96.1, UMS 96, BT 450.1-96) M12 connectors (KD …) Ready-made cables (K-D …) Alignment aid ARH 96 ISO 9001 U L US C LISTED IEC 60947... IEC 60947... IP IP 69K 69K IP IP 67 67 Dimensioned drawing A Indicator diode green B Indicator diode yellow C Optical axis D Device plug M12x1 E Screwed cable gland M16x1.5 for Ø 5 … 10mm F Countersinking for SK nut M5, 4.2 deep G Connection terminals H Cable entry I Sensitivity adjustment Electrical connection Transmitter Receiver LS 96 Throughbeam photoelectric sensors Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Embed Size (px)

Citation preview

Page 1: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Leuze electronicW

e re

serv

e th

e rig

ht to

mak

e ch

ange

s •

96_a

02e.

fm

Throughbeam photoelectric sensors with high performance reserve in infrared light

Robust metal housing with glass cover, pro-tection class IP 67/IP 69K for industrial application

Complementary outputs, sensitivity adjustment and delay before start-up for optimal adaptation to the application

Connection via M12 connector or terminal compartmentMultiple options with warning output, activation input, switching delays and optics heating for use at low temperatures

150m

10 - 30 V

DCA2

LS

Accessories:(available separately)

Mounting systems(BT 96, BT 96.1, UMS 96, BT 450.1-96)M12 connectors (KD …)

Ready-made cables (K-D …)Alignment aid ARH 96

ISO9001

UL USC

LISTED

IEC 60947... IEC 60947...IPIP 69K69KIPIP 6767

Dimensioned drawing

A Indicator diode greenB Indicator diode yellowC Optical axisD Device plug M12x1E Screwed cable gland M16x1.5 for Ø 5 … 10mmF Countersinking for SK nut M5, 4.2 deepG Connection terminalsH Cable entryI Sensitivity adjustment

Electrical connectionTransmitter Receiver

LS 96 Throughbeam photoelectric sensors

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 2: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Leuze electronic

SpecificationsOptical data Infrared light Typ. operating range limit 1)

1) Typ. operating range limit: max. attainable range without performance reserve

0 … 150m Operating range 2)

2) Operating range: recommended range with performance reserve

0 … 120mLight source LED (modulated light) Wavelength 880nm

TimingSwitching frequency 500HzResponse time 1msDelay before start-up ≤ 200ms

Electrical dataOperating voltage UB 10 … 30VDC (incl. residual ripple)Residual ripple ≤ 15% of UBBias current ≤ 50mA, ≤ 130mA with optional optics heatingSwitching output PNP transistorFunction characteristics light/dark switchingSignal voltage high/low ≥ (UB-2V)/≤ 2V (PNP)Output current max. 100mASensitivity adjustable

IndicatorsLED green readyLED yellow light path free LED yellow flashing light path free, no performance reserve

Mechanical data Metal housingHousing diecast zincOptics cover glassWeight 380gConnection type terminals, M12 connector

Environmental dataAmbient temp. (operation/storage) -20°C … +60°C/-40°C … +70°CProtective circuit 3)

3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs

1, 2, 3VDE safety class 4)

4) Rating voltage 250VAC

II, all-insulatedProtection class IP 67, IP 69K 5)

5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,acids and bases are not part of the test

LED class 1 (acc. to EN 60825-1)Standards applied IEC 60947-5-2

OptionsActivation input activTransmitter active/not active ≥ 8V/≤ 2V (≥ 2V/≤ 2V) 6)

6) Active high

Activation/disable delay ≤ 0.5msInput resistance 47KΩ ± 10%Warning output autoControl warn PNP transistor, 100mA, counting principleOptics heating for temperature changes, prevents foggingLow temperature to -35°CSwitching delay (slow oper./release) 0 … 10s (separately adjustable)

Order guideSelection table

Order code

Equipment LS

96M

/P-3

010-

2P

art N

o. 5

00 2

5225

(Tr

)P

art N

o. 5

00 3

4128

(R

e)

LS

96M

/P-3

010-

4P

art N

o. 5

00 2

5228

(Tr

)P

art N

o. 5

00 3

4128

(R

e)

LS

96M

/P-3

012-

2P

art N

o. 5

00 2

5223

(Tr

)P

art N

o. 5

00 3

3328

(R

e)

LS

96M

/P-3

012-

4P

art N

o. 5

01 0

3290

(Tr

)P

art N

o. 5

01 0

3291

(R

e)

Housing metalLight source infrared light (120m)Connection terminals

M12 connectorFeatures optics heating/low temp.

activation input 6) 6)

Tables0 120 150

Operating range [m]Typ. operating range limit [m]

Remarks

LS 96M/P-3010-2LSS 96M-1070-23LSE 96M/P-3010-21

LS 96M/P-3010-4LSS 96M-1070-43LSE 96M/P-3010-41

LS 96M/P-3012-2LSS 96M-1090-24LSE 96M/P-3012-21

LS 96M/P-3012-4LSS 96M-1090-43LSE 96M/P-3012-41

LS = Pair consisting ofLSS = TransmitterLSE = Receiver

LS 96

Diagrams

-3,5

-2,5

-1,5

-0,5

0,50

1,5

2,5

3,5

0 20 40 60 80 100 120 140 160

y1

y2

Distance x [m]

Mis

alig

nmen

t y [m

]

Typ. response behaviour

y2

y1

x

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 3: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Leuze electronicW

e re

serv

e th

e rig

ht to

mak

e ch

ange

s •

96_a

11e.

fm

Throughbeam photoelectric sensors with high performance reserve in visible red light or infrared lightRobust metal housing with glass cover or plastic housing, protection class IP 67 for industrial applicationComplementary outputs for standard appli-cations and a wide range of input and output variants for optimum adaptation to the applicationMultiple options with warning output, activation input, switching delays and optics heating for use at low temperatures

39m65m

10 - 30 V

DCA2

LS

Accessories:(available separately)

Mounting systems(BT 96, BT 96.1, UMS 96, BT 450.1-96)M12 connectors (KD …)

Ready-made cables (K-D …)Alignment aid ARH 96

ISO9001

UL USC

LISTED

IEC 60947... IEC 60947... IP 67

Dimensioned drawing

A Indicator diode greenB Indicator diode yellowC Optical axisD Device plug M12x1E Device plug M18x1F Screwed cable gland M16x1.5 for Ø 5 … 10mmG Countersinking for SK nut M5, 4.2 deepH Connection terminalsI Cable entryK Sensitivity adjustment

Electrical connection

LS 96 Throughbeam photoelectric sensors

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 4: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Leuze electronic

SpecificationsOptical data Infrared light Red light Typ. operating range limit 1)

1) Typ. operating range limit: max. attainable range without performance reserve

0 … 65m 0 … 39mOperating range 2)

2) Operating range: recommended range with performance reserve

0 … 50m 0 … 30mLight source LED (modulated light) LED (modulated light)Wavelength 880nm 660nm

TimingSwitching frequency 500HzResponse time 1msDelay before start-up ≤ 200ms

Electrical dataOperating voltage UB 10 … 30VDC (incl. residual ripple)Residual ripple ≤ 15% of UBBias current ≤ 50mA, ≤ 130mA with optional optics heating Switching output NPN or PNP transistorFunction characteristics light/dark switchingSignal voltage high/low ≥ (UB-2V)/≤ 2V (PNP)Output current max. 100mASensitivity adjustable

IndicatorsLED green readyLED yellow light path free LED yellow flashing light path free, no performance reserve

Mechanical data Plastic housingHousing polycarbonateOptics cover plasticWeight 150g Connection type terminals or M12 connector

Environmental dataAmbient temp. (operation/storage) -20°C … +60°C/-40°C … +70°CProtective circuit 3)

3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs

1, 2, 3VDE safety class 4)

4) Rating voltage 250VAC

II, all-insulated Protection class IP 67LED class 1 (acc. to EN 60825-1)Standards applied IEC 60947-5-2

OptionsActivation input activTransmitter active/not active ≤ 2V/≥ 8V 5)

5) Active low

Activation/disable delay ≤ 0.5msInput resistance 47KΩ ± 10%Warning output autoControl warn PNP transistor, 100mA, counting principleOptics heating for temperature changes, prevents foggingLow temperature to -35°CSwitching delay (slow oper./release) 0 … 10s (separately adjustable)

Order guideSelection table

Order code

Equipment LS

96K

/P-1

010-

4P

art N

o. 5

00 2

5254

(Tr

)P

art N

o. 5

00 2

5258

(R

e)

LS

96K

/P-1

030-

2P

art N

o. 5

00 2

5255

(Tr

)P

art N

o. 5

00 2

5259

(R

e)

LS

96K

/P-1

030-

4P

art N

o. 5

00 2

5254

(Tr

)P

art N

o. 5

00 8

0483

(R

e)

LS

96K

/P-1

140-

2P

art N

o. 5

00 8

0657

(Tr

)P

art N

o. 5

00 3

1295

(R

e)

LS

96K

/P-1

015-

4P

art N

o. 5

00 2

5254

(Tr

)P

art N

o. 5

01 0

3004

(R

e)

LS

96K

/P-1

010.

1-4

Par

t No.

500

252

54 (

Tr)

Par

t No.

501

032

18 (

Re)

Housing metalplastic

Light source red light (30m)infrared light (50m)

Connection terminalsM12 connector

Features switching delaywarning outputactivation input 5)

PIN 2 = NC *PIN 4 = dark switchingPIN 4 = light/dark reversible

TablesRed light

Infrared light

0 30 39

0 50 65

Operating range [m]Typ. operating range limit [m]

RemarksThe throughbeam photoe-lectric sensor is also available with integrated AS-i chip for direct con-nection to the AS-i system.*For direct connection to AS-i I/O coupling modules(LS 96K/P-1015-4 andLS 96K/P-1010.1-4)

LS 96

DiagramsRed light

Infrared light

-400

-300

-200

-100

0

100

200

300

400

0 5 10 15 20 25 30 35 40 45 50

y1

y2

Distance x [m]

Mis

alig

nmen

t y [m

]

Typ. response behaviour

-1,0-0,8-0,6-0,4-0,2

00,20,40,60,81,0

0 10 20 30 40 50 60 70

y1

y2

Distance x [m]

Mis

alig

nmen

t y [m

]

Typ. response behaviour

y2

y1

x

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 5: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Leuze electronicW

e re

serv

e th

e rig

ht to

mak

e ch

ange

s •

96_a

09e.

fm

Throughbeam photoelectric sensors with high performance reserve in red light

Robust metal housing with glass cover, pro-tection class IP 67/IP 69K for industrial application

Receiver with integrated AS-i slave technologyTransmitter without integrated AS-i slave technology; receives voltage supply via AS-i lineWide angle version to simplify the alignment

39m

Accessories:(available separately)

Mounting systems(BT 96, BT 96.1, UMS 96, BT 450.1-96)M12 connectors

Ready-made cables (K-D …)Alignment aid ARH 96

AS-i Accessories:(available separately)

Bus terminals

AS-i ribbon cableAddress programming deviceCoupling modules, intermediate cables, etc.

ISO9001

UL USC

LISTED

IEC 60947... IEC 60947...IPIP 69K69KIPIP 6767

Dimensioned drawing

A Indicator diode greenB Indicator diode yellowC Optical axisD Device plug M12x1E Countersinking for SK nut M5, 4.2 deep

Electrical connection

LS 96 Throughbeam photoelectric sensors

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 6: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Leuze electronic

SpecificationsOptical data Typ. operating range limit 1)

1) Typ. operating range limit: max. attainable range without performance reserve

0 … 39mOperating range 2)

2) Operating range: recommended range with performance reserve

0 … 30m Light source LED (modulated light)Wavelength 660nm (red light)

TimingSensor switching frequency 500Hz Sensor response time 1ms Delay before start-up ≤ 200ms

Electrical data Operating voltage UB 26.5 … 31.6V (according to AS-i specification)Bias current receiver ≤ 35mA Bias current transmitter ≤ 15mA

IndicatorsLED green readyLED yellow light path free LED yellow flashing light path free, no performance reserve

Mechanical data Metal housingHousing diecast zincOptics cover glassWeight 380g Connection type M12 connector

Environmental dataAmbient temp. (operation/storage) -20°C … +60°C/-40°C … +70°C Protective circuit 3)

3) 1=transient protection, 2=polarity reversal protection

1, 2 VDE safety class 4)

4) Rating voltage 250VAC

II, all-insulated Protection class IP 67, IP 69K 5)

5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,acids and bases are not part of the test

LED class 1 (acc. to EN 60825-1)Standards applied IEC 60947-5-2

AS-i data for receiver I/O code 1ID code 1Cycle time acc. to AS-i specification 5msAS-i standard according to profile S-1.1

Assignment: data bits Assignment: parameter bitsProgramming(host level)

Programming(host level)

D0Switching out-put

Ø no reflection System input *P0 NC

Ø System parameter1 reflection 1

D1Warning output autoControl

Ø active System input *P1

Light/dark switching

Ø dark switching System parameter1 not active 1 light switching

D2 Ready outputØ sensor not ready System

input *P2 NCØ System

parameter1 sensor ready 1

*D3 NCØ

*P3 NCØ System

parameter1 1* default = 1

Order guideDesignation Part No.

Transmitter and receiver LS 96M/A-182W-4Transmitter LSS 96 M-180W-44 500 82040Receiver LSE 96 M/A-182W-44 500 82039

Tables0 30 39

Operating range [m]Typ. operating range limit [m]

RemarksThe transmitter has no integrated AS-i slave technology.The low current consumption of the transmitter enables power supply via AS-i line.

Transmitter and receiver behave like a slave in an AS-i branch.

Angle at 3m distance:Transmitter:Angle of radiation typ.: 10°Receiver:Receiving angle typ.: 12°

LS 96

Diagrams

-400

-300

-200

-100

0

100

200

300

400

0 5 10 15 20 25 30 35 40 45 50

y1

y2

Distance x [m]

Mis

alig

nmen

t y [m

m]

Typ. response behaviour

y2

y1

x

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 7: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Leuze electronicW

e re

serv

e th

e rig

ht to

mak

e ch

ange

s •

96_a

06e.

fm

Throughbeam photoelectric sensors with high performance reserve in red light

Wide angle version for easy alignmentRobust metal housing with glass cover, pro-tection class IP 67/IP 69K for industrial applicationAll-mains design 20 … 230VAC/DC with relay output

Relay with change-over contact, sensitivity adjustment and delay before start-up for optimal adaptation to the application

Connection via comfortable terminal com-partment up to 1.5mm2

39m

20-230 V

AC / DCA2

LS

Accessories:(available separately)

Mounting systems (BT 96, BT 96.1, BT 96.4, UMS 96, BT 450.1-96)

Spark extinctionAlignment aid ARH 96

ISO9001

UL USC

LISTED

IEC 60947... IEC 60947...IPIP 69K69KIPIP 6767

Dimensioned drawing

A Indicator diode greenB Indicator diode yellowC Optical axisD Screwed cable gland M16x1.5 for Ø 5 … 10mmE Countersinking for SK nut M5, 4.2 deepF Connection terminalsG Cable entryH Sensitivity adjustment

Electrical connection (example)

Transmitter

Receiver

LS 96 Throughbeam photoelectric sensors

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 8: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Leuze electronic

SpecificationsOptical data Typ. operating range limit 1)

1) Typ. operating range limit: max. attainable range without performance reserve

0 … 39m Operating range 2)

2) Operating range: recommended range with performance reserve

0 … 30mLight source LED (modulated light) Wavelength 660nm (red light)

TimingSwitching frequency 20HzResponse time 25msDelay before start-up ≤ 200ms

Electrical dataOperating voltage UB 20 … 230VAC, 50/60Hz

20 … 230VDCPower consumption ≤ 1.5VA Switching output 3)

3) Suitable spark extinction must be provided with inductive or capacitive loads

relay, 1 change-over contactFunction characteristics break-contact/make-contactSwitching voltage, relay 250VAC/DCSwitching current, relay 250VAC, 3A/30V, 3ABias current 750VA, cosϕ=1Sensitivity adjustable

IndicatorsLED green readyLED yellow light path freeLED yellow flashing light path free, no performance reserve

Mechanical data Metal housing Housing diecast zincOptics cover glassWeight 380gConnection type terminals

transmitter cable 3x0.5mm2 (oil flex 110), 1.5mreceiver cable 3x0.5mm2 (oil flex 110), 1.5m

Environmental dataAmbient temp. (operation/storage) -20°C … +60°C/-40°C … +70°CProtective circuit 4)

4) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs

1, 2, 3VDE safety class 5)

5) Rating voltage 250VAC

II, all-insulated Protection class IP 67, IP 69K 6)

6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,acids and bases are not part of the test

LED class 1 (acc. to EN 60825-1)Standards applied IEC 60947-5-2

Order guideSelection table

Order code

Equipment LS

96M

/R-1

76W

-2P

art N

o. 5

00 3

2004

(Tr

)P

art N

o. 5

00 3

2003

(R

e)

Housing metalLight source red light (30m)Connection terminals

cable tail 1.5m

Tables0 30 39

Operating range [m]Typ. operating range limit [m]

RemarksAngle at a distance of 3m:transmitter:angle of radiation typ. 10°receiver:receiving angle typ. 12°Cable versionwire assignment:1,2 = supply3,4 = break-contact

LS 96M/R-176W-2LSS 96M-175W-26LSE 96M/R-176W-25

LS = Pair consisting ofLSS = TransmitterLSE = Receiver

LS 96

Diagrams

-1250-1000

-750-500-250

0250500750

10001250

0 10 20 30 40

y1

y2

Distance x [m]

Mis

alig

nmen

t y [m

m]

Typ. response behaviour

y2

y1

x

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 9: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

We

rese

rve

the

right

to

mak

e ch

ange

s •

DS

_LS

96M

KR

_en_

5012

0809

.fm

Throughbeam photoelectric sensors withhigh performance reserve in infrared light

Robust metal housing with glass cover orplastic housing, protection class IP 67/IP 69K for industrial application

All-mains design 20 … 230VAC/DC Relay with change-over contact, sensitivity

adjustment and delay before start-up foroptimal adaptation to the application

Connection via comfortable terminalcompartment up to 1.5mm²

Version with additional switching delay

65m150m

20-230 V

AC / DCA2

LS

Accessories:(available separately)

Mounting systems(BT 96, BT 96.1, UMS 96, BT 450.1-96)

Spark extinction Alignment aid ARH 96

IEC 60947... IEC 60947...IPIP 69K69KIPIP 6767

Dimensioned drawing

A Green indicator diodeB Yellow indicator diodeC Optical axisD Screwed cable gland M16x1.5 for Ø 5 … 10mmE Countersinking for SK nut M5, 4.2 deepF Connection terminalsG Cable entryH Sensitivity adjustment

Electrical connection (example)

Transmitter

Receiver

LS 96 Throughbeam photoelectric sensors

en 1

0-20

12/0

850

1208

09

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 10: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Specifications

Approved purpose:This product may only be used by qualified personnel and must only be used for theapproved purpose. This sensor is not a safety sensor and is not to be used for the protection of persons.

Optical data 65m 150m Typ. operating range limit 1)

1) Typ. operating range limit: max. attainable range without performance reserve

0 … 65m 0 … 150mOperating range 2)

2) Operating range: recommended range with performance reserve

0 … 50m 0 … 120mLight source LED (modulated light) Wavelength 880nm (infrared)

TimingSwitching frequency 20HzResponse time 25msDelay before start-up 200ms

Electrical dataOperating voltage UB 20 … 230VAC, 50/60Hz

20 … 230VDCPower consumption 1.5VA Switching output 3)

3) Suitable spark extinction must be provided with inductive or capacitive loads

relay, 1 change-over contactFunction characteristics break-contact/make-contactSwitching voltage, relay 250VAC/DCSwitching current, relay 250VAC, 3A/30V, 3AOpen-circuit current 750VA, cos=1Sensitivity adjustable

IndicatorsGreen LED readyYellow LED light path freeYellow LED, flashing light path free, no performance reserve

Mechanical data Metal housing Plastic housingHousing diecast zinc polycarbonateOptics cover glass plasticWeight 380g 150gConnection type terminals terminals

Environmental dataAmbient temp. (operation/storage) -30°C … +60°C/-40°C … +70°CProtective circuit 4)

4) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs

1, 2, 3VDE safety class 5)

5) Rating voltage 250VAC

II, all-insulated Protection class IP 67, IP 69K 6)

6) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,acids and bases are not part of the test

IP 67Light source exempt group (in acc. with EN 62471)Standards applied IEC 60947-5-2

OptionsSwitching delay (slow oper./release) 0 … 10s (separately adjustable)

Order guideSelection table

Order code

Equipment LS 9

6K/R

-131

0-2

Par

t N

o. 5

0025

253

(Tr)

Par

t N

o. 5

0025

257

(Re)

LS 9

6K/R

-132

0-2

Par

t N

o. 5

0025

253

(Tr)

Par

t N

o. 5

0025

256

(Re)

LS 9

6M/R

-131

0-2

Par

t N

o. 5

0080

081

(Tr)

Par

t N

o. 5

0080

080

(Re)

LS 9

6M/R

-331

0-2

Par

t N

o. 5

0080

081

(Tr)

Par

t N

o. 5

0031

651

(Re)

LS96

K/R

-131

P-2

Par

t N

o. 5

0030

405

(Tr)

Par

t N

o. 5

0030

406

(Re)

Housing metal plastic

Light source infrared light (50m) infrared light (120m)

Connection terminals Features switching delay

UL homologation

Tables65m models

150m models

0 50 65

0 120 150

Operating range [m]Typ. operating range limit [m]

Remarks LS 96K/R-131P-2

P = Reduction M16

LS 96K/R-1310-2LSS 96K-1350-26LSE 96K/R-1310-25

LS 96K/R-1320-2LSS 96K-1350-26LSE 96K/R-1320-25

LS 96M/R-1310-2LSS 96M-1350-26LSE 96M/R-1310-25

LS 96M/R-3310-2LSS 96M-1350-26LSE 96M/R-3310-25

LS 96K/R-131P-2 LSS 96K-135P-26LSE 96K/R-131P-25

LS = Pair consisting ofLSS = TransmitterLSE = Receiver

LS 96

Diagrams65m models

150m models

-1,0-0,8-0,6-0,4-0,2

00,20,40,60,81,0

0 10 20 30 40 50 60 70

y1

y2

Distance x [m]

Mis

alig

nmen

t y [m

]

Typ. response behaviour

-3,5

-2,5

-1,5

-0,5

0,50

1,5

2,5

3,5

0 20 40 60 80 100 120 140 160

y1

y2

Distance x [m]

Mis

alig

nmen

t y [m

]

Typ. response behaviour

y2

y1

x

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 11: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Leuze electronicW

e re

serv

e th

e rig

ht to

mak

e ch

ange

s •

96_a

03e.

fm

Powerful throughbeam photoelectric sen-sors with performance reserve in visible red lightWide angle version for easy alignmentRobust metal housing with glass cover, pro-tection class IP 67/IP 69K for industrial applicationComplementary outputs, sensitivity adjustment and delay before start-up for optimal adaptation to the applicationConnection via M12 connector or comforta-ble terminal compartment up to 1.5mm2

39m

10 - 30 V

DCA2

LS

Accessories:(available separately)

Mounting systems(BT 96, BT 96.1, UMS 96, BT 450.1-96)M12 connectors (KD …)

Ready-made cables (K-D …)Alignment aid ARH 96

ISO9001

UL USC

LISTED

IEC 60947... IEC 60947...IPIP 69K69KIPIP 6767

Dimensioned drawing

A Indicator diode greenB Indicator diode yellowC Optical axisD Device plug M12x1E Screwed cable gland M16x1.5 for Ø 5 … 10mmF Countersinking for SK nut M5, 4.2 deepG Connection terminalsH Cable entryI Sensitivity adjustment

Electrical connection

Transmitter Receiver

LS 96 Throughbeam photoelectric sensors

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 12: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Leuze electronic

SpecificationsOptical data Red light Typ. operating range limit 1)

1) Typ. operating range limit: max. attainable range without performance reserve

0 … 39mOperating range 2)

2) Operating range: recommended range with performance reserve

0 … 30mLight source LED (modulated light)Wavelength 660nm

TimingSwitching frequency 500HzResponse time 1msDelay before start-up ≤ 200ms

Electrical dataOperating voltage UB 10 … 30VDC (incl. residual ripple)Residual ripple ≤ 15% of UBBias current ≤ 50mASwitching output PNP transistorFunction characteristics light/dark switchingSignal voltage high/low ≥ (UB-2V)/≤ 2V (PNP)Output current max. 100mASensitivity adjustable

IndicatorsLED green readyLED yellow light path freeLED yellow flashing light path free, no performance reserve

Mechanical data Metal housing Housing diecast zincOptics cover glassWeight 380gConnection type terminals, M12 connector

Environmental dataAmbient temp. (operation/storage) -20°C … +60°C/-40°C … +70°CProtective circuit 3)

3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs

1, 2, 3VDE safety class 4)

4) Rating voltage 250VAC

II, all-insulated Protection class IP 67, IP 69K 5)

5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,acids and bases are not part of the test

LED class 1 (acc. to EN 60825-1)Standards applied IEC 60947-5-2

Order guideSelection table

Order code

Equipment LS

96M

/P-1

81W

-4P

art N

o. 5

00 3

1574

(Tr

)P

art N

o. 5

00 3

1575

(R

e)

LS

96M

/P-1

81W

-2P

art N

o. 5

00 3

2835

(Tr

)P

art N

o. 5

00 3

2741

(R

e)

LS

96M

/P-1

816-

4P

art N

o. 5

00 3

2129

(Tr

)P

art N

o. 5

00 3

2128

(R

e)

Housing metalLight source red light (30m)Connection terminals

M12 connectorFeatures fixed sensitivity setting

optics heating/low temp.

Tables0 30 39

Operating range [m]Typ. operating range limit [m]

RemarksAngle at a distance of 3m:transmitter:angle of radiation typ. 10°receiver:receiving angle typ. 12°

LS 96M/P-181W-4LSS 96M-120W-43LSE 96M/P-181W-41

LS 96M/P-181W-2LSS 96M-120W-23LSE 96M/P-181W-21

LS 96M/P-1816-4LSS 96M-1206-43LSE 96M/P-1816-41

LS = Pair consisting ofLSS = TransmitterLSE = Receiver

LS 96

Diagrams

-400

-300

-200

-100

0

100

200

300

400

0 5 10 15 20 25 30 35 40 45 50

y1

y2

Distance x [m]

Mis

alig

nmen

t y [m

m]

Typ. response behaviour

y2

y1

x

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 13: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Leuze electronicW

e re

serv

e th

e rig

ht to

mak

e ch

ange

s •

96_a

01e.

fm

Throughbeam photoelectric sensors with high performance reserve in visible red light or infrared lightRobust metal housing with glass cover or plastic housing, protection class IP 67/IP 69K for industrial applicationComplementary outputs, sensitivity adjustment and delay before start-up for optimal adaptation to the applicationConnection via M12 connector or terminal compartment

Multiple options with warning output, activation input, switching delays and optics heating for use at low temperatures

39m65m

10 - 30 V

DCA2

LS

Accessories:(available separately)

Mounting systems(BT 96, BT 96.1, UMS 96, BT 450.1-96)

M12 connectors (KD …)Ready-made cables (K-D …)Alignment aid ARH 96

ISO9001

UL USC

LISTED

IEC 60947... IEC 60947...IPIP 69K69KIPIP 6767

Dimensioned drawing

A Indicator diode greenB Indicator diode yellowC Optical axisD Device plug M12x1E Device plug M18x1F Screwed cable gland M16x1.5 for Ø 5 … 10mmG Countersinking for SK nut M5, 4.2 deepH Connection terminalsI Cable entryK Sensitivity adjustment

Electrical connection

LS 96 Throughbeam photoelectric sensors

Specifications and description

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Page 14: Leuze LS 96 Throughbeam Photoelectric Sensors - … photoelectric sensors with ... optimal adaptation to the application ... zBus terminals zAS-i ribbon cable

Leuze electronic

SpecificationsOptical data Infrared light Red light Typ. operating range limit 1)

1) Typ. operating range limit: max. attainable range without performance reserve

0 … 65m 0 … 39mOperating range 2)

2) Operating range: recommended range with performance reserve

0 … 50m 0 … 30mLight source LED (modulated light) LED (modulated light)Wavelength 880nm 660nm

TimingSwitching frequency 500HzResponse time 1msDelay before start-up ≤ 200ms

Electrical dataOperating voltage UB 10 … 30VDC (incl. residual ripple)Residual ripple ≤ 15% of UBBias current ≤ 50mA, ≤ 130mA with optional optics heating Switching output NPN or PNP transistorFunction characteristics light/dark switchingSignal voltage high/low ≥ (UB-2V)/≤ 2V (PNP)Output current max. 100mASensitivity adjustable

IndicatorsLED green readyLED yellow light path free LED yellow flashing light path free, no performance reserve

Mechanical data Metal housing Housing diecast zincOptics cover glass Weight 380gConnection type terminals or M12 connector

Environmental dataAmbient temp. (operation/storage) -20°C … +60°C/-40°C … +70°CProtective circuit 3)

3) 1=transient protection, 2=polarity reversal protection, 3=short-circuit protection for all outputs

1, 2, 3VDE safety class 4)

4) Rating voltage 250VAC

II, all-insulated Protection class IP 67, IP 69K 5)

5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,acids and bases are not part of the test

LED class 1 (acc. to EN 60825-1)Standards applied IEC 60947-5-2

OptionsActivation input activTransmitter active/not active ≥ 8V/≤ 2V (≥ 2V/≤ 2V) 6)

6) Active high

Activation/disable delay ≤ 0.5msInput resistance 47KΩ ± 10%Warning output autoControl warn PNP transistor, 100mA, counting principleOptics heating for temperature changes, prevents foggingLow temperature to -35°CSwitching delay (slow oper./release) 0 … 10s (separately adjustable)

Order guideSelection table

Order code

Equipment LS

96M

/P-1

040-

4P

art N

o. 5

00 2

5228

(Tr

)P

art N

o. 5

00 2

5205

(R

e)

LS

96M

/P-1

130-

2P

art N

o. 5

00 2

5223

(Tr

)P

art N

o. 5

00 2

5201

(R

e)

LS

96M

/P-1

170-

2P

art N

o. 5

00 2

5217

(Tr

)P

art N

o. 5

00 2

5195

(R

e)

LS

96M

/P-1

170-

4P

art N

o. 5

00 2

5219

(Tr

)P

art N

o. 5

00 2

5197

(R

e)

LS

96M

/N-1

010-

2P

art N

o. 5

00 2

5225

(Tr

)P

art N

o. 5

00 3

1295

(R

e)

Housing metalplastic

Light source red light (30m)infrared light (50m)

Connection terminalsM12 connector

Features optics heating/low temp.switching delaywarning outputactivation input 6)

NPN switching output

TablesRed light

Infrared light

0 30 39

0 50 65

Operating range [m]Typ. operating range limit [m]

RemarksThe throughbeam photoe-lectric sensor is also available with integrated AS-i chip for direct con-nection to the AS-i system.

LS 96

DiagramsRed light

Infrared light

-400

-300

-200

-100

0

100

200

300

400

0 5 10 15 20 25 30 35 40 45 50

y1

y2

Distance x [m]

Mis

alig

nmen

t y [m

m]

Typ. response behaviour

-1,0-0,8-0,6-0,4-0,2

00,20,40,60,81,0

0 10 20 30 40 50 60 70

y1

y2

Distance x [m]

Mis

alig

nmen

t y [m

]

Typ. response behaviour

y2

y1

x

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]