28
07.07.2021 27771 AXC 30 M Installer manual Accessories LEK

LEK Installer manual Accessories

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LEK Installer manual Accessories

07.07.202127771

AXC 30 MInstaller manual

Accessories

LEK

Page 2: LEK Installer manual Accessories

2 AXC 30M

Table of Contents

1 General ___________________ 3Contents __________________________ 3Technical data ______________________ 3Component positions _________________ 3

2 Common electrical connection 4Connecting communication ____________ 4Connecting the supply ________________ 4

3 Shunt controlled additional heat _5General ___________________________ 5Pipe connections ____________________ 5Outline diagram _____________________ 6Electrical connection _________________ 7Program settings ____________________ 8Electrical circuit diagram ______________ 9

4 Extra climate system _______ 10General __________________________ 10Pipe connections ___________________ 10Outline diagram _____________________11Electrical connection ________________ 12Program settings ___________________ 13Electrical circuit diagram _____________ 14

5 Hot water comfort __________ 15General __________________________ 15Pipe connections ___________________ 15Outline diagram ____________________ 16Electrical connection ________________ 17Program settings ___________________ 18Electrical circuit diagram _____________ 19

6 Active cooling (4-pipe) ______ 20General __________________________ 20Pipe connections ___________________ 20Outline diagram ____________________ 21Electrical connection ________________ 22Program settings ___________________ 23Wiring diagram ____________________ 24

7 Connection of several heat pumps _ 25General __________________________ 25Pipe connections ___________________ 25Outline diagram ____________________ 25Explanation _______________________ 25Electrical connection ________________ 26Program settings ___________________ 27Electrical circuit diagram _____________ 28

Page 3: LEK Installer manual Accessories

3AXC 30M

1 GeneralThis accessory is used to enable connection and control of (a AXC 30M is required for each of the fol-lowing accessory functions that is used):• Shunt controlled additional heat• Step controlled additional heat• Extra climate system• Hot water comfort• Active cooling (4-pipe)• Connection of several heat pumps

Contents

COMPATIBLE PRODUCTS

4 x Cable ties2 x Heating pipe paste1 x Insulation tape1 x Unit box with accessory card2 x Aluminium tape2 x Temperature sensor

• HMA 60- S• HMA 100- S

• RC-HY 40• RC-HY 40-W

Component positions

Designations in component locations according tostandard IEC 81346-1 and 81346-2.

AA25-FC1 Miniature circuit breaker, 10 AAA25-X1 Terminal block, power supplyAA5 Accessory cardAA5-X2 Terminal block, sensors and external blockingAA5-X4 Terminal block, communicationAA5-X9 Terminal block, circulation pumps and reversing valveAA5-S2 DIP switchAA5-F1 Fine wire fuse, T4AH250V

Electrical components

AA5-X4 AA5-S2

AA5-X2

AA5

AA25-X1

AA5-X9

AA5-F1

AA25-FC1

Technical dataTechnical specifications

AXC 30MDimensions (WxDxH) mm 250x100x175

Page 4: LEK Installer manual Accessories

4 AXC 30M

2 Common electrical connectionNOTEAll electrical connections must be carried out by an au-thorised electrician.Electrical installation and wiring must be carried out in accordance with the stipulations in force.The heat pump must not be powered when installing AXC 30M.

Electrical circuit diagrams are at the end of the chap-ter for each connection option.

Connecting communicationControl module

RC-HY 40/RC-HY40-W contains an accessory card (AA5) which isconnected for communication.If several accessories are to be connected or are already installed, the following instructions must be followed.The first external accessory card must be connected directly to terminal block AA5-X4 in the control mod-ule.The following cards must be connected in series with the previous card.Use cable type LiYY, EKKX or similar.

1

2

3

4

5

6

7

8

AA5-X4

4

A

B

GND

A

B

GND

A

B

GND

A

B

GND

A

B

GND5

6

AA5-X4

1

2

3

4

5

6

7

8

AA5-X4

RC-HY 40

Accessory card 1

Accessory card 2

ON1

23

45

67

8

-X9

-X2

24 202122 5132 161718 0191 111213 541 678 19

1

N

L

PE

PE

1

2

3

4

5

6

7

8

2

3

4

5

6

7

8

9234

-X8

-X4

-X10

-X1

AA5-X4

ON1

23

45

67

8

-X9

-X2

24 202122 5132 161718 0191 111213 541 678 19

1

N

L

PE

PE

1

2

3

4

5

6

7

8

2

3

4

5

6

7

8

9234

-X8

-X4

-X10

-X1

AA5-X4

EB15

AA5-X4

L N 1 1 0 2 3 4PE

1 2 3 4

LEK

ON

12345678

-X9

-X2

24

20

21

22

23

15

16

17

18

19

10

11

12

13

14

5

6

7

8

9

1

1NLPEPE

12345678

2 3 4 5 6 7 8 9

2

3

4

-X8

-X4

-X10-X1

Connecting the supplyConnect the power supply to terminal block X1 as il-lustrated.

3

2

1 N230V 50Hz-X1

LPE

Page 5: LEK Installer manual Accessories

5AXC 30M

3 Shunt controlled additional heatGeneralThis function enables an external additional heater, e.g. an oil boiler, gas boiler or district heating ex-changer to aid with heating.The indoor module controls a shunt valve and a cir-culation pump (GP10) via the accessory card in AXC 30M. If the heat pump does not manage to keep the correct supply temperature (BT25), the addition starts. When the boiler temperature of (BT52) has been increased to about 55 °C, the indoor module transmits a signal to the shunt (QN11) to open from the addition. The shunt (QN11) adjusts so the true supply temperature corresponds with the indoor module’s theoretical calculated set point value. When the heating demand drops sufficiently so the addition-al heat is no longer required the shunt (QN11) clos-es completely. Factory set minimum run time holding the boiler prepared is 12 hours (can be set in menu 5.3.2).

Pipe connectionsThe external circulation pump (GP10) is positioned according to the outline diagram.

Shunt valveThe shunt valve (QN11) is located on the flow line tothe climate system after the heat pump according tothe outline diagram.

• Connect the flow line from the heat pump to the ex-ternal heat source via the T-pipe to port B on the shunt valve (closes at re-duced signal).

AB

B

A

• Connect the flow line to the climate system from the shunt valve to the common port AB (always open)

• Connect the flow line from the external addition-al heat to the shunt valve to port A (opens at in-creased signal).

Temperature sensor• Install the boiler sensor (BT52) in a suitable loca-

tion in the external addition.• External supply temperature sensor (BT25, con-

nected in the indoor module’s control module) must be installed on the supply line to the radia-tors, after the shunt valve (QN11).

K

Install the temperature sensors with cable ties with the heat conducting paste and aluminium tape. Then insulate with supplied insulation tape.

NOTESensor and communication cables must not be placed near power cables.

Page 6: LEK Installer manual Accessories

6 AXC 30M

Outline diagramExplanationEM1 Shunt controlled additional heat, boilerAA25 Accessory card (AXC 30M)BT52 Temperature sensor, boilerCM5 Expansion vessel, closedEM1 Oil/gas boilerFL10 Safety valve, heating medium sideQN11 Mixing valve, additionFDCW Heat pump systemFDCW Heat pumpMiscellaneousAA25 RC-HY 40/RC-HY40-WBT1 Outdoor sensorBT3 Temperature sensor, heating me - dium returnBT6 Temperature sensor, hot water chargingBT7 Temperature sensor, hot water, topBT15 Temperature sensor, liquidBT12 Temperature sensor, condenser outletBT25 Temperature sensor, heating medium flow, External

BT50 Room sensor, extra climate systemBT63 Temperature sensor, heating medium supply downstream the submersible heaterBT64 Temperature sensor, cooling medium supplyBT71 Temperature sensor, heating medium return, ExternalGP10 Circulation pump, heating medium externalGP11 Hot water circulation pumpGP12 Circulation pump, climate systemQN10 Reversing valve, hot waterQN12 Isolation valve, cooling/heatingHS1 Drying filterBP4 High pressure sensorEB1 External electrical additional heatXL1 Connection, heating medium flowXL2 Connection, heating medium returnXL10 Connection, cooling medium flow

Designations according to standards 81346-1 and81346-2.

Outline diagram RC-HY 40/RC-HY40-W with AXC 30M and shunt controlled additional heat

-BT6

-BT7

-BT3

-BP4

HS1 -BT15 -BT71

-BT12-BT25

-BT63

-BT64-GP12

-QN12

-QN10

-GP11

-EB1

XL1 XL2

FDCW

-BT1

AA25

HMK 100 XL10

-BT25

-BT71

-GP10

-BT50

-QN11

-BT52

-AA25

-CM5

-FL10

-EM1

-EM1

Page 7: LEK Installer manual Accessories

7AXC 30M

Electrical connection

ON1

23

45

67

8

-X9

-X2

24 202122 5132 161718 0191 111213 541 678 19

1

N

L

PE

PE

1

2

3

4

5

6

7

8

2

3

4

5

6

7

8

9234

-X8

-X4

-X10

-X1

NOTEAll electrical connections must be carried out by an au-thorised electrician.Electrical installation and wiring must be carried out in accordance with the stipulations in force.RC-HY 40 must not be powered when installingAXC 30M.

Connection of sensors and external blocking

Use cable type LiYY, EKKX or similar.

Boiler sensor (BT52)Connect the boiler sensor to AA5-X2:23-24.

External blocking (optional)A contact (NO) can be connected to AA5-X2:21-22 toblock the addition. When the contact closes, the ad-dition is blocked.

24 202122 5132 161718 3191 14

M

CAUTIONThe relay outputs on the accessory card can have a max load of 2 A (230 V) in total.

Connection of the circulation pump (GP10)

Connect the circulation pump (GP10) to AA5-X9:8 (230V), AA5-X9:7 (N) and X1:3 (PE)

1

2

3

4

5

6

7

8

9L

N

PE

3

2

1

M

Connection of the mixing valve motor(QN11)

Connect the mixing valve motor (QN11) to AA5-X9:6(230 V, open), AA5-X9:5 (N) and AA5-X9:4 (230 V,close).

1

2

3

4

5

6

7

8

9

M

Connection of the auxiliary relay for ad-ditional heating

Connect the auxiliary relay for switching the additionon and off to AA5-X9:2 (230 V) and AA5-X9:3 (N).

1234

L

N

A1 A2

External auxiliary relay

AdditionalHeating

M

Page 8: LEK Installer manual Accessories

8 AXC 30M

DIP switchThe DIP switch on the accessory card must be set asfollows.

ON1

23

45

67

8

ON1

23

45

67

8

-X9

-X2

24 202122 5132 161718 0191 111213 541 678 19

1

N

L

PE

PE

1

2

3

4

5

6

7

8

2

3

4

5

6

7

8

9234

-X8

-X4

-X10

-X1

Program settingsProgram setting of AXC 30M can be performed via the start guide or directly in the menu system.

Start guideThe start guide appears upon first start-up after heatpump installation, but is also found in menu 5.7.

Menu systemIf you do not make all settings via the start guide orneed to change any of the settings, this can be donein the menu system.

Menu 5.2 - system settingsActivating/deactivating of accessories.Select: “shunt controlled add. heat”.

Menu 5.3.2 - shunt controlled add. heatHere you can perform the following settings:• Select when the addition is to start.• Minimum running time.• Minimum boiler temperature at which the shunt

can start control.• Misc. shunt settings.

Menu 5.6 - forced controlForced control of the different components in indoor module as well as in the different accessories that may be connected.EM1-AA5-K1: Activating the relay for additional heat-ing.EM1-AA5-K2: Signal (close) to mixing valve (QN11).EM1-AA5-K3: Signal (open) to mixing valve (QN11).EM1-AA5-K4: Activating the circulation pump (GP10).

CAUTIONAlso see the Installer manual for RC-HY 40.

Page 9: LEK Installer manual Accessories

9AXC 30M

Electrical circuit diagram

Page 10: LEK Installer manual Accessories

10 AXC 30M

General

4 Extra climate systemPipe connections

This accessory function is used when RC-HY 40, RC-HY40-W and HMA-S unit is installed in houses with up to eight different climate systems that require different flow line temperatures, for example, in cases where the house has both a radiator system and an under floor heating system.

When connecting extra climate systems, they must be connected so that they have a lower working tem-perature than the climate system 1.

General

K

The mixing valve (QN25) is located on the flow line after the heat pump/indoor module, before the first radiator in the climate system 1. The return line from the additional climate system must be connected to the shunt valve and to the return line fromthe heating system 1, see image and outline diagram.

NOTEThis symbol indicates danger to person or machine.NOTESensor and communication cables must notbe placed near power cables.

CAUTIONUnderfloor heating systems are normally max flow line temperature set between 35 and 45 °C.Check the max temperature for your floor with your floor supplier.

CAUTIONIf the roomsensor is used in a roomwith under floor heating it should only have an indicatory function, not control of the roomtemperature.

The extra circulation pump (GP10) is positioned in theextra climate system according to the outline diagram.

Circulation pump

Shunt valve

• Connect the flow line to the climate system from the heat pump to port A on the shunt valve (opens at in-creased signal)

• Connect the flow line to the climate system to the common port AB on the shunt valve (always open).

B

A

AB

• Connect the return line from the cli-mate system to port B on the shunt valve via the T-pipe to (closes at re-duced signal).

• The flow temperature sensor (BT2) is installed on the pipe between the circulation pump (GP10) and mixing valve (QN25).

• The return line sensor (BT3) is installed on the pipe from the extra climate system.

Temperature sensor

Install the temperature sensors with cable ties with the heat conducting paste and aluminium tape. Then insulate with supplied insulation tape.

Page 11: LEK Installer manual Accessories

11AXC 30M

Outline diagramExplanation

Designations in component locations according tostandard IEC 81346-1 and 81346-2.

Outline diagram RC-HY 40/RC-HY40-W with AXC 30M and up to three extra climate systems

-BT6

-BT7

-BT3

-BP4

HS1 -BT15 -BT71

-GP11

-BT12-BT25

-BT63

-BT64-GP12

-QN12

-QN10-EB1

XL1

-QN25

-QN25

-GP10

-GP10

-BT3

-BT3

-BT50

-BT2

-BT2

XL2

FDCW

-BT1

AA25

EP21

EP22

EP23

AA25

AA25

HMK 100 XL10

-QN25

-GP10

-BT3

-BT2AA25

FDCW Heat pump systemFDCW Heat pump

MiscellaneousXL1 Connection, heating medium flowXL2 Connection, heating medium returnEP21 Climate system 2 (ECS 40M/ECS 41M)EP22 Climate system 3 (ECS 40M/ECS 41M)EP23 Climate system 4 (ECS 40M/ECS 41M)AA25 RC-HY 40/RC-HY40-WBT1 Outdoor sensorBT2 Flow temperature sensor, extra climate systemBT3 Temperature sensor, heating me - dium returnBT6 Temperature sensor, hot water chargingBT7 Temperature sensor, hot water, topBT15 Temperature sensor, liquidBT12 Temperature sensor, condenser outletBT25 Temperature sensor, heating medium flow, External

BT50 Room sensor, extra climate systemBT63 Temperature sensor, heating medium supply downstream the submersible heaterBT64 Temperature sensor, cooling medium supplyBT71 Temperature sensor, heating medium return, ExternalGP10 Circulation pump, heating medium externalGP11 Hot water circulation pumpGP12 Circulation pump, climate systemQN10 Reversing valve, hot waterQN12 Isolation valve, cooling/heatingQN25 Shunt valveHS1 Drying filterBP4 High pressure sensorXL10 Connection, cooling medium flowEB1 External electrical additional heat

Page 12: LEK Installer manual Accessories

12 AXC 30M

Electrical connection

ON1

23

45

67

8

-X9

-X2

24 202122 5132 161718 0191 111213 541 678 19

1

N

L

PE

PE

1

2

3

4

5

6

7

8

2

3

4

5

6

7

8

9234

-X8

-X4

-X10

-X1

NOTEAll electrical connections must be carried out by an au-thorised electrician.Electrical installation and wiring must be carried out in accordance with the stipulations in force.RC-HY 40/RC-HY 40-W and HMA-S unit must not be powered when installing AXC 30M.

Connection of sensors and external ad-justment

Use cable type LiYY, EKKX or similar.

Flow temperature sensor, extra climate system(BT2)Connect the boiler sensor to AA5-X2:23-24.

Return line sensor, extra climate system (BT3)Connect the return line sensor to AA5-X2:21-22.

CAUTIONThe relay outputs on the accessory card can have a max load of 2 A (230 V) in total.

Connection of the circulation pump (GP10)

Connect the circulation pump(GP10) to AA5-X9:8 (230 V), AA5-X9:7 (N) and X1:3(PE).

Room temperature sensor, extra climate system(BT50) (optional)Connect the room temperature sensor to AA5-X2:19-20.

External adjustment (optional)A potential free switch can be connected to AA5- X2:17-18 for external adjustment of the climate sys-tem.

24 202122 6132 171819

1

2

3

4

5

6

7

8

9LN

PE

32

1

10

Connection of the mixing valve motor(QN25)

Connect the mixing valve motor (QN25) to AA5-X9:6(230 V, open), AA5-X9:5 (N) and AA5-X9:4 (230 V,close).

1

2

3

4

5

6

7

8

9

M

Page 13: LEK Installer manual Accessories

13AXC 30M

DIP switchThe DIP switch on the accessory card must be set asfollows.

Program settingsProgram setting of AXC 30M can be performed via the start guide or directly in the menu system.

Start guideThe start guide appears upon first start-up after heatpump/indoor module installation, but is also found inmenu 5.7.

Menu systemIf you do not make all settings via the start guide orneed to change any of the settings, this can be donein the menu system

Menu 5.2.4 - accessoriesActivating/deactivating of accessories.Select: “climate system 2”, “climate system 3”, “cli-mate system 4”, “climate system 5”, “climate system 6”, “climate system 7” and/or “climate system 8” de-pending on how many climate systems are installed.

Menu 5.6 - forced controlForced control of the different components in the heatpump as well as in the different accessories that maybe connected. 2 is climate system, EP22, 3 is climatesystem EP23, 4 is climate system EP21.EP2#-AA5-K1: No function.EP2#-AA5-K2: Signal (close) to mixing valve (QN25).EP2#-AA5-K3: Signal (open) to mixing valve (QN25).EP2#-AA5-K4: Activating the circulation pump (GP10).

CAUTIONAlso see the Installer manual for relevant heat pump/indoor module.

ON1

23

45

67

8

-X9

-X2

24 202122 5132 161718 0191 111213 541 678 19

1

N

L

PE

PE

1

2

3

4

5

6

7

8

2

3

4

5

6

7

8

9234

-X8

-X4

-X10

-X1

AA5-S2

Climate system

432

ON1

23

45

67

8

ON1

23

45

67

8

ON1

23

45

67

8

5

ON1

23

45

67

8

876

ON1

23

45

67

8

ON1

23

45

67

8

ON1

23

45

67

8

Menu 5.1.2 - max flow line temperatureSetting the maximum flow temperature for each cli-mate system.

Menu 5.3.3 - extra climate systemMixing valve settings for extra installed climate sys-tem.

Menu 1.1 - temperatureSetting the indoor temperature.

Menu 1.9.1 - heating curveSetting the heat curve.

Menu 1.9.2 - external adjustmentSetting external adjustment.

Menu 1.9.3 - min. flow line temp.Setting theminimumflow temperature for each climatesystem.

Menu 1.9.4 - room sensor settingsActivating and setting the room temperature sensor.

Page 14: LEK Installer manual Accessories

14 AXC 30M

Electrical circuit diagram

Page 15: LEK Installer manual Accessories

15AXC 30M

General

5 Hot water comfortPipe connections

This function allows temporary lux, mixing valve andhot water circulation.

The mixing valve (FQ1) is located on the outgoing hotwater line from the water heater according to the out-line diagram.

Mixing valve

K

NOTEThis symbol indicates danger to person or machine.NOTESensor and communication cables must notbe placed near power cables.

• Temperature sensor, outgoing hot water, (BT70) installed in a suitable place after the mixing valve (FQ1).

Temperature sensor

Install the temperature sensors with cable ties with the heat conducting paste and aluminium tape. Then insulate with supplied insulation tape.

If an immersion heater is installed in the tank it can bepermitted to produce hot water, at the same time asthe heat pump prioritises heating.

Temporary lux (extra hot water)

A temperature sensor reads the temperature of theoutgoing hot water to the domestic hot water and ad-justs the mixing valve from the water heater until the set temperature has been reached.

Mixing valve

One pump can be controlled for the circulation of thehot water during selectable periods.

Hot water circulation (VVC)

• Connect the incoming cold water via the T-pipe to the port B on the mixing valve (closes at signal).

• Connect the mixed water to the domestic hot water taps from the mixing valve to the common port AB (always open).

AB

A

B

• Connect the outgoing hot water from the waterheater to the mixing valve to port A(opens on signal).

Page 16: LEK Installer manual Accessories

16 AXC 30M

Outline diagramExplanation

Outline diagram RC-HY 40/RC-HY40-W with AXC 30M and hot water comfort

-BT6

-BT7

-BT3

-BP4

HS1 -BT15 -BT71-BT70-FQ1

-GP11

-EB10

-AA25-BT12

-BT25

-BT63

-BT64-GP12

-QN12

-QN10-EB1

XL1 XL2

FDCW

-BT1

AA25

HMK 100

-QZ1

XL10

-RN20

-RN23

-BT25

-BT71

-GP10

-BT50

-QN11

-BT52

-AA25

-CM5

-FL10

-EM1

-EM1

EB1 External additional heatCM5 Expansion vessel, closedEB1 External electrical additional heatFL10 Safety valve, heating medium sideQN11 Mixing valve, additionFDCW Heat pump systemFDCW Heat pump

QZ1 Hot water comfortAA25 Accessory card AXC 30MBT70 Temperature sensor, outgoing hot waterEB10 Additional water heaterFQ1 Mixer valve, hot waterRN23 Non-return valveRN20 Trim valveGP11 Hot water circulation pump

MiscellaneousXL1 Connection, heating medium flowXL2 Connection, heating medium returnBT1 Outdoor sensorBT3 Temperature sensor, heating me - dium return

BT6 Temperature sensor, hot water chargingBT7 Temperature sensor, hot water, topBT15 Temperature sensor, liquidBT12 Temperature sensor, condenser outletBT25 Temperature sensor, heating medium flow, ExternalBT50 Room sensor, extra climate systemBT63 Temperature sensor, heating medium supply downstream the submersible heaterBT64 Temperature sensor, cooling medium supplyBT71 Temperature sensor, heating medium return, ExternalGP10 Circulation pump, heating medium externalGP12 Circulation pump, climate systemQN10 Reversing valve, hot waterQN12 Isolation valve, cooling/heatingHS1 Drying filterBP4 High pressure sensorEM1 Shunt controlled additional heat, boilerXL10 Connection, cooling medium flow

Page 17: LEK Installer manual Accessories

17AXC 30M

Electrical connection

ON1

23

45

67

8

-X9

-X2

24 202122 5132 161718 0191 111213 541 678 19

1

N

L

PE

PE

1

2

3

4

5

6

7

8

2

3

4

5

6

7

8

9234

-X8

-X4

-X10

-X1

NOTEAll electrical connections must be carried out by an au-thorised electrician.Electrical installation and wiring must be carried out in accordance with the stipulations in force.RC-HY 40, RC-HY40-W and HMA-S must not be pow-ered when installing AXC 30M.

Connecting sensorsUse cable type LiYY, EKKX or similar.

How water sensor, flow line (BT70)Connect hot water sensor to AA5-X2:23-24.

CAUTIONThe relay outputs on the accessory card can have a max load of 2 A (230 V) in total.

24 202122 5132 161718 3191 14

M

Connection of the hot water circulationpump (GP11)

Connect the circulation pump (GP11) to AA5-X9:8 (230 V), AA5-X9:7 (N) and X1:3 (PE).

1

2

3

4

5

6

7

8

9L

N

PE

3

2

1

Unit box External

GP11

AA5-X9 X1

Connection of the mixing valve (FQ1)Connect the mixing valve motor (FQ1) to AA5-X9:6 (230 V, open), AA5-X9:5 (N) and AA5-X9:4 (230 V, close).

1

2

3

4

5

6

7

8

9

M

Connecting auxiliary relay for temporary lux (extra hot water)

Connect the auxiliary relay for switching the additionon and off to AA5-X9:1 (N) and AA5-X9:2 (230 V).

1234

L

N

A2 A1

External auxiliary relay

AdditionalHot water

M

Page 18: LEK Installer manual Accessories

18 AXC 30M

DIP switchThe DIP switch on the accessory card must be set asfollows.

Program settingsProgram setting of AXC 30M can be performed via the start guide or directly in the menu system.

Start guideThe start guide appears upon first start-up after heatpump installation, but is also found in menu 5.7.

Menu systemIf you do not make all settings via the start guide orneed to change any of the settings, this can be donein the menu system.

Menu 5.2.4 - accessoriesActivating/deactivating of accessories.Select: “hot water comfort”.

CAUTIONAlso see the Installer manual for RC-HY 40.

Menu 2.9.2 - hot water recirc.Here you can make the following settings for hot wa-ter circulation for up to three periods per day:• How long the hot water circulation pump must run

per operating instance• How long the hot water circulation pump must be

stationary between operating instances.

Menu 5.3.8 - hot water comfortHere you can perform the following settings:• If an immersion heater is installed in the tank and

whether it can be permitted to charge hot water if the compressors in the heat pump prioritise heat-ing.

• Whether a mixing valve for limiting the tempera-ture of hot water from the water heater is installed.

• Various shunt settings and outgoing hot water temperature from the tank for the mixing valve.

ON1

23

45

67

8

ON1

23

45

67

8

-X9

-X2

24 202122 5132 161718 0191 111213 541 678 19

1

N

L

PE

PE

1

2

3

4

5

6

7

8

2

3

4

5

6

7

8

9234

-X8

-X4

-X10

-X1

Menu 5.6 - forced controlForced control of the different components in the heat pump as well as in the different accessories that may be connected.QZ1-AA5-K1: Activating the relay for extra hot water.QZ1-AA5-K2: Signal (close) to the mixing valve (FQ1).QZ1-AA5-K3: Signal (open) to the mixing valve (FQ1).QZ1-AA5-K4: Activating the circulation pump (GP11).

Page 19: LEK Installer manual Accessories

19AXC 30M

Electrical circuit diagram

Page 20: LEK Installer manual Accessories

20 AXC 30M

General

6 Active cooling (4-pipe)Pipe connections

Connecting this accessory makes it possible to con-trol production of cooling.The cooling system supplies cooling from the heat pump using a circulation pump (GP12) via a revers-ing valve (QN12).For the installation to work the cooling system must flow freely permanently, for example using a volume vessel for cooling.Operating mode cooling is activated by the tempera-ture of the outdoor sensor (BT1) and any room tem-perature sensors (BT50), room units or separate room sensors for cooling (BT74) (if two different rooms areto be heated respectively cooled at the same time forexample.)When cooling is required, the cooling reversing valve (QN12) and the circulation pump (GP13) are activat-ed.Cooling production is regulated according to the cool-ing sensor (BT64) and a cooling set point value that is determined by the selected cooling curve.Cooling degree minutes are calculated in response tothe value on the external temperature sensor (BT64) for cooling out and the cooling set point value.As an accessory, cooling reversing valve is required.

Pipes and other cold surfaces must be insulated withdiffusion-proof material to prevent condensation.Where the cooling demand is high, fan convectors with drip trays and drain connection are needed.

General

K

NOTEThis symbol indicates danger to person or machine.NOTESensor and communication cables must notbe placed near power cables.

Temperature sensor (BT64) is mounted on the sup-plyline to the cooling system at the T-pipe connection to the volume vessel (CP21).

Temperature sensor

Install the temperature sensors with cable ties with the heat conducting paste and aluminium tape. Then insulate with supplied insulation tape.

The reversing valve (QN12) is located in the system on the supply line from the heat pump

General

AB

B A

Page 21: LEK Installer manual Accessories

21AXC 30M

Outline diagramExplanation

Outline diagram RC-HY 40/RC-HY40-W with AXC 30M and active cooling (4-pipe)

-BT6

-BT7

-BT3

-BP4

HS1 -BT15 -BT71

-GP11

-BT12-BT25

-BT63

-BT64-GP12

-QN12

-QN10-EB1

XL1

-BT50

XL2

FDCW

-BT1

AA25

-EQ1

HMK 100 XL10

-AA25-AA5-CP6

-GP13

-BT64

-QN25

-GP10

-BT3

-BT2

-EP21-AA25

EQ1 Cooling systemAA25-AA5 Accessory card in AXC 30MBT64 Temperature sensor, flow line coolingCP6 Accumulator tank, coolingGP13 Cooling circulation pump FDCW Heat pump systemFDCW Heat pumpMiscellaneousAA25 RC-HY 40/RC-HY40-WBT1 Outdoor sensorBT2 Flow temperature sensor, extra climate systemBT3 Temperature sensor, heating me - dium returnBT6 Temperature sensor, hot water chargingBT7 Temperature sensor, hot water, topBT15 Temperature sensor, liquidBT12 Temperature sensor, condenser outletBT25 Temperature sensor, heating medium flow, External

BT50 Room sensor, extra climate systemBT63 Temperature sensor, heating medium supply downstream the submersible heaterBT71 Temperature sensor, heating medium return, ExternalGP10 Circulation pump, heating medium externalGP11 Hot water circulation pumpGP12 Circulation pump, climate systemQN10 Reversing valve, hot waterQN12 Isolation valve, cooling/heatingQN25 Shunt valveHS1 Drying filterBP4 High pressure sensorXL1 Connection, heating medium flowXL2 Connection, heating medium returnXL10 Connection, cooling medium flowEB1 External electrical additional heat

Page 22: LEK Installer manual Accessories

22 AXC 30M

Electrical connection

NOTEAll electrical connections must be carried out by an au-thorised electrician.Electrical installation and wiring must be carried out in accordance with the stipulations in force.RC-HY 40, RC-HY40-W and HMA-S must not be pow-ered when installing AXC 30M.

Connection of sensors and external blocking

Use cable type LiYY, EKKX or similar.

Temperature sensor (BT64)Connect the sensor to AA5-X2:19-20.

ON1

23

45

67

8

-X9

-X2

24 202122 5132 161718 0191 111213 541 678 19

1

N

L

PE

PE

1

2

3

4

5

6

7

8

2

3

4

5

6

7

8

9234

-X8

-X4

-X10

-X1

Temperature sensor (roomsensor for cooling, BT74)An extra temperature sensor (room sensor for cool-ing) can be connected to RC-HY 40/RC-HY40-W in order to better determine when it is time to switch be-tween heating and cooling operation.Connect the temperature sensor to one of the AUX inputs X6:7-19 on terminal block X6 which are behindthe front hatch in RC-HY 40. The actual AUX input is selected in menu 5.4. Connect ground to terminal block X6:GND. Use a 2 core cable of at least 0.5 mm2 cable area.Place the temperature sensor in a neutral position in the room where the set temperature is required. It is important that the sensor is not obstructed from mea-suring the correct room temperature by being located, for example, in a recess, between shelves, behind a curtain, above or close to a heat source, in a draft froman external door or in direct sunlight. Closed ra-diator thermostats can also cause problems.

Room sensor (BT50)To connect the roomsensor (BT50), see the Installa-tion manual for RC-HY 40/RC-HY40-W and HMA-S.

External blocking (optional)A contact can be connected to AA5-X2:21-22 to blockcooling operation. When the contact closes, coolingoperation is blocked.

24 202122 5132 161718 3191 14

AA5-X2

BT64

External blocking

CAUTIONThe relay outputs on the accessory card can have a max load of 2 A (230 V) in total.

Connection of the cooling circulation pump (GP13)

Connect the circulation pump(GP13) to AA5-X9:6 (230 V), AA5-X9:5 (N) and X1:3 (PE)

0 32PE

123456789

AXC 30 External

AA5-X9

X1

GP13

M

Connecting the charge pump (GP12)Do not connect charge pump GP12 to the accessorycard. See Installation manual to connect charge pumpGP12.

Page 23: LEK Installer manual Accessories

23AXC 30M

Connection of the reversing valve motor(QN12)

Connect the motor (QN12) to AA5-X9:2 (signal), AA5-X9:1 (N) and AA5-X10:2 (230 V).

Program settingsProgram setting of AXC 30M can be performed via the start guide or directly in the menu system.

Start guideThe start guide appears upon first start-up after heatpump installation, but is also found in menu 5.7.

Menu systemIf you do not make all settings via the start guide orneed to change any of the settings, this can be donein the menu system.

Menu 5.2.4 - accessoriesActivating/deactivating of accessories.Select: “active cooling 4 pipe”.

Menu 1.1 - temperatureSetting indoor temperature (room temperature sen-sor is required).

Menu 1.9.5 - cooling settingsHere you can perform the following settings:• Lowest flow line temperature when cooling.• Desired flow temperature at an outdoor air tem-

perature of +20 and +40 °C.• Time between cooling and heating operation and

vice versa.• Selection of room sensor can control cooling.• How much the room temperature may decrease

or increase compared to the desired temperature before switching to heating respectively cooling (requires room sensor).

• Degree minute levels for cooling.

Menu 4.9.2 - auto mode settingWhen heat pump operating mode is set to “auto“ it selects when start and stop of additional heat, heat production and cooling is permitted, dependent on the average outdoor temperature.Select the average outdoor temperatures in this menu.You can also set the time over which (filtering time) the average temperature is calculated. If you select 0, the present outdoor temperature is used.

DIP switchThe DIP switch on the accessory card must be set asfollows.

-X10

123456789

AXC 30 External

AA5-X9

AA5-X10

QN12BlackBlue

Brown

M

ON1

23

45

67

8AA5-S2

Menu 5.6 - forced controlForced control of the different components in the heatpump as well as in the different accessories that maybe connected.EQ1-AA5-K1: Signal to three way valve (QN12).EQ1-AA5-K3: Signal cooling circulation pump (GP13).

CAUTIONAlso see the Operating manual for RC-HY 40, RC-HY40-W and HMA-S.

Page 24: LEK Installer manual Accessories

24 AXC 30M

Wiring diagramRC

-HY

40

Page 25: LEK Installer manual Accessories

25AXC 30M

General

Pipe connections

7 Connection of several heat pumpsOutline diagram

Explanation

This function allows control of up to two extra charge pumps GP12. The accessory is required for the charge pump for slave -EB10x address 3 or greater. Up to 8 slaves can be combined in one system.The control module controls the charge pumps to-gether with the relevant slave during operation. A CPD type charge pump is recommended in order to use speed control, which ensures correct delta-t in the different operating modes during the year. The accessory also enables external blocking of each as-sociated slave.

The charge pump (GP12) is positioned in the relevant charge circuit before joining with other charge circuits or branching off different sub-systems via a reversing valve.

Real installations must be planned according to appli-cable standards.

EB101-EB104 Heat pumpGP12 Charge pump RM11 Non-return valve

MiscellaneousAA25 RC-HY 40/RC-HY40-W

--EB101

-RM11-AA25-GP12

-RM11-GP12

-RM11-GP12

-RM11-GP12

--EB10

--EB10

-EB103

-AA25

Page 26: LEK Installer manual Accessories

26 AXC 30M

Electrical connection

NOTEAll electrical connections must be carried out by an au-thorised electrician.Electrical installation and wiring must be carried out in accordance with the stipulations in force.RC-HY 40/RC-HY40-W must not be powered wheninstalling AXC 30M.

Connection of sensors and external blocking

Use cable type LiYY, EKKX or similar.

External blocking (optional)A contact can be connected to AA5-X2:23-24 to blockcooling the accessory function. When the contact closes, the entire accessory function is blocked.A further contact can be connected to AA5-X2:17-18 to block the accessory function. When the contact closes, the accessory function FDCWY is blocked.A further contact can be connected to AA5-X2:15-16 to block the accessory function. When the contact closes, the accessory function FDCWX is blocked.

ON1

23

45

67

8

-X9

-X2

24 202122 5132 161718 0191 111213 541 678 19

1

N

L

PE

PE

1

2

3

4

5

6

7

8

2

3

4

5

6

7

8

9234

-X8

-X4

-X10

-X1

CAUTIONThe relay outputs on the accessory card can have a max load of 2 A (230 V) in total.

Connection of the circulation pump (GP12)

Connect the circulation pump (FDCWX-GP12) to AA5-X9:4 (230 V), AA5-X9:3 (N) and X1:3 (PE).Connect the circulation pump (FDCWY-GP12) to AA5- X9:6 (230 V), AA5-X9:5 (N) and X1:3 (PE).

24 202122 5132 161718 3191 14

Externalblocking

AA5-X2

FDCWY-GP12 FDCWX-GP12

3

2

1

123456789

PMW

PMW

GN

D

GN

D

987654

AXC 30 External

FDCWY-GP12

FDCWX-GP12AA5-X9

X1

AA5-X2

M

DIP switchThe DIP switch on the accessory card must be set asfollows.

7-85-63-4

ON1

23

45

67

8

ON1

23

45

67

8

ON1

23

45

67

8

Page 27: LEK Installer manual Accessories

27AXC 30M

Program settingsProgram setting of multi-installation during operationof several heat pumps can be performed via the startguide or directly in the menu system.

Start guideThe start guide appears upon first start-up after heatpump installation, but is also found in menu 5.7.

Menu systemIf you do not make all settings via the start guide orneed to change any of the settings, this can be donein the menu system.

Menu 5.2.2 - installed slavesActivating/deactivating slaves

Menu 5.2.3 - dockingEnter how your system is docked regarding pipes, forexample to pool heating, hot water heating and heat-ing the building.

This menu has a docking memory which means thatthe control system remembers how a particular re-versing valve is docked and automatically enters the correct docking the next time you use the same re-versing valve.Master/slave: Select which heat pump the docking setting is to be made for (if the heat pump is alone in the system only master is displayed).Compressor: Select if your compressor in the heat pump is blocked (factory setting), externally con-trolled via soft input or standard (docked for example to pool heating, hot water charging and heating the building).Marking frame: Move around the marking frame us-ing the control knob. Use the OK button to select what you want to change and to confirm setting in the op-tions box that appears to the right.Workspace for docking: The system docking is drawn here.

DescriptionSymbol

Compressor (blocked)

Compressor (externally controlled)

Compressor (standard)

Reversing valves for hot water control.

The designations above the reversing valveindicate where it is electrically connected(FDCW1 = Slave 1, CL11 = Pool 1 etc.).

DescriptionSymbol

Own hot water charging, only from selec-ted heat pump compressor. Controlled byrelevant heat pump.Pool 1

Pool 2

Heating (heating the building, includes anyextra climate system)

Menu 5.11.1 - FDCW3Make settings for the installed slaves here.

Menu 5.6 - forced controlForced control of the different components in the heatpump as well as in the different accessories that maybe connected.• Compressor speed 3• FDCW3 - GP12 - AA5-K2• Charge pump speed 3• Compressor speed 4• FDCW4 - GP12 - AA5-K3• Charge pump speed 4

CAUTIONAlso see the Installer manual for RC-HY 40 / RC-HY40-W.

Page 28: LEK Installer manual Accessories

28 AXC 30M

Electrical circuit diagram

M