1
FLOOR PLAN FLOOR PLAN FOR MORE INFO: RICH GASPERINI FirstVice President +1 412 394 9806 [email protected] MATEO VILLA Associate +1 412 394 9837 [email protected] 180 LEETSDALE INDUSTRIAL DRIVE LEETSDALE INDUSTRIAL PARK A8.00 1 A4.00 3 48'-0"L. RAMP UP 287'-1" 23'-10 1 2 " 21'-6" 90'-10 1 2 " 25'-8" 23'-0" 21'-6" 21'-6" 21'-6" 21'-6" 21'-6" 21'-6" 21'-6" 21'-6" 21'-6" 21'-6" 23'-5" 2'-5" 18'-0" 21'-4" 16'-8" 8'-0" MIN 4'-9" 1 1 2 " G.C. to PROVIDE LOOP BOLSTER for TRAIN STOP - COORDINATE w/ OWNER G.C. to FURNISH & INSTALL NEW REINFORCED CONCRETE or C.M.U. WALL, FOUNDATION, and FOOTER. PROVIDE 4'W. OPENING w/ LINTEL as REQUIRED 1'-4" 4'-0" SPRKLR. ROOM 8' x 8' LOCKER ROOM 1'-9" 1'-0" 1'-6" 12' x 12' O.H. DOOR - FAIL CLOSE 2-HR. FIRE-RATED SHAFT WALL (3-3/4"T.) UL #U497 ELEC. ROOM 12'-0" 12'-0" 12' x 15' TRNFR. PAD 15'-0" EXISTING PLUMBING SUPPLY - G.C. SHALL F.V. LOCATION EXTENDED PLUMBING SUPPLY - G.C. SHALL F.V. EXTENT 18'-0" NEW 42"H. GUARDRAIL w/ REMOVABLE SECTION(S) - G.C. to COOR. w/ OWNER & TENANT 6"Ø LINE ALL EXISTING CONCRETE FOUNDATIONS TO BE REUSED, SEE STRUCTURAL DRAWINGS - TYP. ALL EXISTING CONCRETE FOUNDATIONS TO BE REUSED, SEE STRUCTURAL DRAWINGS - TYP. 8'-0" MIN 1'-0" 91'-0" 10'-9" 13'-0" 10'-9" ELEV. @ 708'-0" ELEV. @ 708'-0" 5'-1" C/L of DOOR

LEETSDALE INDUSTRIAL DRIVE FLOOR PLAN - CBREUSproperties.cbre.us/leetsdale-industrial-park/assets/building-180... · 180 leetsdale industrial drive leetsdale industrial park a8.00

Embed Size (px)

Citation preview

FLOOR PLAN

FLOOR PLAN

FOR MOREINFO:

RICH GASPERINIFirst Vice President+1 412 394 [email protected]

MATEO VILLAAssociate+1 412 394 [email protected]

180 LEETSDALE INDUSTRIAL DRIVE LEETSDALE INDUSTRIAL PARK

A8.00

1

A4.00

3

48'-0"L.RAMP

UP

287'-1"

BUILDING 70

BU

ILD

ING

401

23'-1

01 2"21

'-6"

90'-1

01 2"

25'-8" 23'-0" 21'-6" 21'-6" 21'-6" 21'-6" 21'-6" 21'-6" 21'-6" 21'-6" 21'-6" 21'-6" 23'-5"

2'-5

"18

'-0"

22'-0

"22

'-0"

22'-0

"

21'-4"

16'-8

"

8'-0" MIN

4'-9"

11 2"

G.C. to PROVIDE LOOPBOLSTER for TRAIN STOP- COORDINATE w/ OWNER

G.C. to FURNISH & INSTALLNEW REINFORCEDCONCRETE or C.M.U. WALL,FOUNDATION, and FOOTER.PROVIDE 4'W. OPENING w/LINTEL as REQUIRED 1'-4"4'-0"

SPRKLR.ROOM

8' x 8'

LOCKERROOM

1'-9"

1'-0"

1'-6

"

12' x 12' O.H.DOOR - FAILCLOSE

2-HR. FIRE-RATEDSHAFT WALL(3-3/4"T.) UL #U497

ELEC.ROOM

12'-0" 12'-0"

12' x 15'TRNFR.

PAD

15'-0

"

EXISTING PLUMBINGSUPPLY - G.C. SHALL F.V.LOCATION

EXTENDED PLUMBINGSUPPLY - G.C. SHALL F.V.EXTENT

18'-0"

NEW 42"H. GUARDRAIL w/REMOVABLE SECTION(S)- G.C. to COOR. w/ OWNER& TENANT

6"Ø LINE

ALL EXISTING CONCRETEFOUNDATIONS TO BEREUSED, SEE STRUCTURALDRAWINGS - TYP.

ALL EXISTINGCONCRETEFOUNDATIONS TOBE REUSED, SEESTRUCTURALDRAWINGS - TYP.

8'-0" MIN

1'-0"

91'-0

"

10'-9

"

13'-0

"

10'-9

"

ELEV. @708'-0"

ELEV. @708'-0"

5'-1"

C/L

of

DO

OR

1A2.01

Partition Plan @ FIRST FLOORSCALE: 3/32" = 1'-0" DRAWING

NORTH