84
LEED v4 and Credits for Wood Use Jim Bowyer Dovetail Partners, Inc. Minneapolis, MN This presentation was developed by a third party and is not funded by WoodWorks or the Softwood Lumber Board.

LEED v4 and Credits for Wood Use - WoodWorks · Course Description This presentation examines changes in the latest version of LEED (LEED v4) and implications for wood use. Particular

Embed Size (px)

Citation preview

LEED v4 and Credits for Wood Use

Jim Bowyer Dovetail Partners, Inc. Minneapolis, MN

This presentation was developed by a third party and is not funded by WoodWorks or the Softwood Lumber Board.

“The Wood Products Council” is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/ CES), Provider #G516.

Credit(s) earned on completion of this program will be reported to AIA/CES for AIA members. Certificates of Completion for both AIA members and non-AIA members are available upon request.

This program is registered with AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. _______________________ Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation.

Course Description

This presentation examines changes in the latest version of LEED (LEED v4) and implications for wood use. Particular attention is given to the Materials and Resources section of the standard where the greatest changes have been made. Environmental Product Declarations (EPDs) and Health Product Declarations (HPDs) – both of which are prominent within LEED v4 – are explained, and their potential use, as well as potential problems in attempting to use, are discussed.

Learning Objectives

• Understand the changes that have been made in the latest version of LEED (v4) and implications for building materials selection and wood use.

• Understand the purpose of EPDs, the science behind them, the nature of information they provide, and how to use them effectively in the building materials selection process.

• Learn the essentials of HPDs and their use.

• Learn current limitations to application of EPDs and alternative approaches to identifying low impact materials.

Focus of Presentation

• Will focus on LEED for New Construction and Major Renovation.

• Within each program will focus on Materials and Resources, and will touch on Indoor Environmental Quality.

Outline

• Overview of Changes from LEED 2009 to LEED v4

• Examination of LCA as a Basis for Understanding EPDs

• Essentials of EPDs and Their Use

• Essentials of HPDs and Their Use

• Awarding of Points within LEED v4

• Wood Use and LEED v4 Summary

Changes to the LEED Standard – an Overview

The main sections of the standard include 100 points. Up to 10 additional points are offered for other project considerations, including: work with a LEED Accredited Professional (1 pt),

compliance with provisions that match areas of regional priority (4 pts), and innovation (5 pts).

Point Thresholds within LEED v4

•  Expanded application to data centers, warehouses, hotels, existing retail and schools, mid-rise residential •  2 additional credit categories: - Location - Integrative Process •  Prerequisites for metering energy and water use •  Energy performance requirements •  Minimum requirements for Energy and Atmosphere and Location and Transportation categories.

Major Changes in LEED v4

Point Distribution In LEED v4 – New Construction and Major Renovation

•  Added prerequisite for waste management

•  New optional credits related to: - Life Cycle Assessment (LCA) - Environmental Product Declarations (EPDs) - Materials ingredients reporting - Reporting of raw materials sourcing and extraction

•  New list of responsible sourcing criteria, including extended producer responsibility, bio-based materials, certified, and recycled content materials.

Major Changes in the Materials and Resources

Category

•  New “locally sourced” definition with a 100 mile limit.

•  Removal of credits for rapidly renewable materials.

Major Changes in the Materials and Resources

Category

Comparison of Materials & Resources – Prerequisites and Credits in LEED 2009 and v4

LEED 2009 – New Construction and Major Renovations

(14 total possible points)

LEED v4 – New Construction and Major Renovations (13 total

possible points)

MRc1 Storage  and  collec-on  of  recyclables  

Required   Prereq.   Storage  and  collec-on  of  recyclables  

Required  

Prereq.   Construc-on  and  demoli-on  waste  management  planning  

Required  

MRc2 Construc-on  waste  management  

2  possible  points  

Credit   Construc-on  waste  management  

2  possible  points  

Comparison of Materials & Resources – Prerequisites and Credits in LEED 2009 and v4

LEED 2009 – New Construction and Major Renovations

(14 total possible points)

LEED v4 – New Construction and Major Renovations (13 total

possible points)

MRc1 Storage  and  collec-on  of  recyclables  

Required   Prereq.   Storage  and  collec-on  of  recyclables  

Required  

Prereq.   Construc-on  and  demoli-on  waste  management  planning  

Required  

MRc2 Construc-on  waste  management  

2  possible  points  

Credit   Construc-on  waste  management  

2  possible  points  

MRc1.1 Building  reuse  –  maintain  exis-ng  walls,  floors,  roof  

3  possible  points  

Now  included  within  building  life  cycle  impact  reduc-on    

 2-­‐5  possible  points    

MRc1.2 Building  reuse  –  maintain  exis-ng  interior  elements  

1  possible  point  

Historic,  blighted  buildings  added    

Comparison of Materials & Resources – Prerequisites and Credits in LEED 2009 and v4

LEED 2009 – New Construction and Major Renovations

(14 total possible points)

LEED v4 – New Construction and Major Renovations (13 total

possible points)

MRc3 Materials  reuse   2  possible  points  

 No  longer  stand-­‐alone  credits  

 Now  included  as  elements  under  Responsible  Sourcing  (6  categories  contribute  to  credit).  

   2  possible  points      

MRc4 Recycled  content   2  possible  points  

MRc7 Cer-fied  wood   1  possible  point  

MRc5 Regional  materials  (500  mile  limit)  

2  possible  points  

No  longer  a  stand-­‐alone  credit  

Can  provide  bonus  credit  only  in  several  specified  credit  areas.  (100  mile  limit)  

             -­‐-­‐-­‐-­‐  

MRc6 Rapidly  renewable  materials  

1  possible  point  

 

Eliminated  

Comparison of Materials & Resources – Prerequisites and Credits in LEED 2009 and v4

LEED 2009 – New Construction and Major Renovations

(14 total possible points)

LEED v4 – New Construction and Major Renovations (13 total

possible points)

   Credit  

Building  product  disclosure  and  op-miza-on  –  Environmental  Product  Declara-ons*  

 2  possible  points  

 Credit  

Building  product  disclosure  and  op-miza-on  –  Material  Ingredients*  

 2  possible  points  

*  Double  credit  for  cost  basis  if  sourced  (raw  materials  extracted,  manufactured,  distributed)  from  within  100  mile  radius.  

Life Cycle Assessment

Determining the Environmental Impact of Products

§  Brainstorming, intuition  

Determining the Environmental Impact of a Product

§  Brainstorming, intuition §  Systematic analysis - - environmental accounting  

Life Cycle Assessment

Determining the Environmental Impact of a Product

Determining the Environmental Impact of a Product

Determining the Environmental Impact of a Product

Life Cycle Inventory (LCI) Examination of all measurable:

•  Raw material inputs

•  Products and by-products

•  Emissions

•  Effluents

•  Wastes

In determining environmental impacts, consider: ● Raw material extraction ● Transportation ● All steps in manufacturing

-  Analyze individual components, wall sections, entire structure.

- Full bill of materials. - Track life cycle environmental impacts of every component. ● Raw material inputs ● Energy consumption ● Emissions ● Effluents ● Solid wastes ● By-products

If the “product” is a component assembled on-site or an entire structure, also assess:

● Transport of materials to construction site ● Building construction ● Operation (heating/cooling) ● Maintenance ● End-of-building-life

Impact Measures Fossil fuel consumption

Weighted resource use

Global warming potential

Smog potential

Acidification potential

Human health respiratory effects

Photochemical oxidation

Ozone layer depletion

Depletion of non-renewable resources

Water consumption

Eutrophication

Solid waste

If comparing two different products: ● They must be functionally equivalent. ● They must be evaluated: - in the same way and in accordance with international protocols. - using the same system boundaries. - including all significant aspects and emission factors.

Steel Design Columns hollow structural section steel, beams wide flange steel; Intermediate floors open-web steel joists w/concrete topping; Exterior walls 2x4 steel studs 16” o.c., R-3.8 rigid insulation sheathing, stucco cladding, R-13 Batt insulation + PET membrane, gypsum board + latex paint; Roof open-web steel joists w/steel decking, R-20 rigid insulation + PET membrane, modified bitumen membrane, gypsum board + latex paint.

Concrete Design Columns reinforced concrete, concrete beams; Intermediate floors pre-cast double-T truss with concrete topping; Exterior walls concrete block w continuous insulation and polyethylene membrane, stucco cladding; Roof pre-cast double-T concrete, R-20 continuous insulation + PET membrane, modified bitumen membrane, latex paint.

ENVIRONMENTAL IMPACT SUMMARY –CONCRETE CONSTRUCTION

Assembly Total area Fossil Fuel Consumpt.

(MJ) TOTAL

Weighted Resource

use (tonnes) TOTAL

GWP (tonnes CO2 eq) TOTAL

Acidification Potential (moles of H

+ eq) TOTAL

HH Respiratory

Effects Potential (kg PM2.5 eq) TOTAL

Eutrophication

Potential (g N eq) TOTAL

Ozone Depletion Potential

(mg CFC-11

eq) TOTAL

Smog potential (g NOx

eq) TOTAL

Foundations & Footings 20000 532,998 581 68 26,524 161 21,288 109 383

Columns and Beams 40000 2,273,849 1,053 167 67,127 388 162,579 198 735

Intermediate Floors 20000 1,081,422 851 117 47,221 347 37,693 183 701

Exterior Walls 12000 3,758,182 662 280 76,860 436 113,229 223 1,051

Windows 0 0 0 0 0 0 0 0 0

Interior Walls 0 0 0 0 0 0 0 0 0

Roof 20000 4,099,144 599 129 66,871 404 32,761 117 1,166

TOTALS 11,745,595 3,746 761 284,604 1,737 367,551 832 4,037

ENVIRONMENTAL IMPACT SUMMARY – STEEL CONSTRUCTION

Assembly Total area Fossil Fuel Consumpt.

(MJ) TOTAL

Weighted Resource

use (tonnes) TOTAL

GWP (tonnes CO2 eq) TOTAL

Acidification Potential (moles of H

+ eq) TOTAL

HH Respiratory

Effects Potential (kg PM2.5 eq) TOTAL

Eutrophication

Potential (g N eq) TOTAL

Ozone Depletion Potential

(mg CFC-11

eq) TOTAL

Smog potential (g NOx

eq) TOTAL

Foundations & Footings 20000 532,998 581 68 26,524 161 21,288 109 383

Columns and Beams 40000 1,400,670 123 56 24,486 114 99,964 0 144

Intermediate Floors 20000 1,428,947 590 101 35,813 266 51,300 71 336

Exterior Walls 12000 992,333 175 63 21,015 191 22,665 25 302

Windows 0 0 0 0 0 0 0 0 0

Interior Walls 0 0 0 0 0 0 0 0 0

Roof 20000 4,405,157 225 117 58,468 335 42,132 5 914

TOTALS 8,760,105 1,693 405 166,307 1,067 237,349 211 2,079

CO

NC

RET

E VS

. STE

EL

ENVIRONMENTAL IMPACT SUMMARY –CONCRETE CONSTRUCTION

Assembly Total area Fossil Fuel Consumpt.

(MJ) TOTAL

Weighted Resource

use (tonnes) TOTAL

GWP (tonnes CO2 eq) TOTAL

Acidification Potential (moles of H

+ eq) TOTAL

HH Respiratory

Effects Potential (kg PM2.5 eq) TOTAL

Eutrophication

Potential (g N eq) TOTAL

Ozone Depletion Potential

(mg CFC-11

eq) TOTAL

Smog potential (g NOx

eq) TOTAL

Foundations & Footings 20000 532,998 581 68 26,524 161 21,288 109 383

Columns and Beams 40000 2,273,849 1,053 167 67,127 388 162,579 198 735

Intermediate Floors 20000 1,081,422 851 117 47,221 347 37,693 183 701

Exterior Walls 12000 3,758,182 662 280 76,860 436 113,229 223 1,051

Windows 0 0 0 0 0 0 0 0 0

Interior Walls 0 0 0 0 0 0 0 0 0

Roof 20000 4,099,144 599 129 66,871 404 32,761 117 1,166

TOTALS 11,745,595 3,746 761 284,604 1,737 367,551 832 4,037

ENVIRONMENTAL IMPACT SUMMARY – STEEL CONSTRUCTION

Assembly Total area Fossil Fuel Consumpt.

(MJ) TOTAL

Weighted Resource

use (tonnes) TOTAL

GWP (tonnes CO2 eq) TOTAL

Acidification Potential (moles of H

+ eq) TOTAL

HH Respiratory

Effects Potential (kg PM2.5 eq) TOTAL

Eutrophication

Potential (g N eq) TOTAL

Ozone Depletion Potential

(mg CFC-11

eq) TOTAL

Smog potential (g NOx

eq) TOTAL

Foundations & Footings 20000 532,998 581 68 26,524 161 21,288 109 383

Columns and Beams 40000 1,400,670 123 56 24,486 114 99,964 0 144

Intermediate Floors 20000 1,428,947 590 101 35,813 266 51,300 71 336

Exterior Walls 12000 992,333 175 63 21,015 191 22,665 25 302

Windows 0 0 0 0 0 0 0 0 0

Interior Walls 0 0 0 0 0 0 0 0 0

Roof 20000 4,405,157 225 117 58,468 335 42,132 5 914

TOTALS 8,760,105 1,693 405 166,307 1,067 237,349 211 2,079

CO

NC

RET

E VS

. STE

EL

ENVIRONMENTAL IMPACT SUMMARY –CONCRETE CONSTRUCTION

Assembly Total area Fossil Fuel Consumpt.

(MJ) TOTAL

Weighted Resource

use (tonnes) TOTAL

GWP (tonnes CO2 eq) TOTAL

Acidification Potential (moles of H

+ eq) TOTAL

HH Respiratory

Effects Potential (kg PM2.5 eq) TOTAL

Eutrophication

Potential (g N eq) TOTAL

Ozone Depletion Potential

(mg CFC-11

eq) TOTAL

Smog potential (g NOx

eq) TOTAL

Foundations & Footings 20000 532,998 581 68 26,524 161 21,288 109 383

Columns and Beams 40000 2,273,849 1,053 167 67,127 388 162,579 198 735

Intermediate Floors 20000 1,081,422 851 117 47,221 347 37,693 183 701

Exterior Walls 12000 3,758,182 662 280 76,860 436 113,229 223 1,051

Windows 0 0 0 0 0 0 0 0 0

Interior Walls 0 0 0 0 0 0 0 0 0

Roof 20000 4,099,144 599 129 66,871 404 32,761 117 1,166

TOTALS 11,745,595 3,746 761 284,604 1,737 367,551 832 4,037

ENVIRONMENTAL IMPACT SUMMARY – STEEL CONSTRUCTION

Assembly Total area Fossil Fuel Consumpt.

(MJ) TOTAL

Weighted Resource

use (tonnes) TOTAL

GWP (tonnes CO2 eq) TOTAL

Acidification Potential (moles of H

+ eq) TOTAL

HH Respiratory

Effects Potential (kg PM2.5 eq) TOTAL

Eutrophication

Potential (g N eq) TOTAL

Ozone Depletion Potential

(mg CFC-11

eq) TOTAL

Smog potential (g NOx

eq) TOTAL

Foundations & Footings 20000 532,998 581 68 26,524 161 21,288 109 383

Columns and Beams 40000 1,400,670 123 56 24,486 114 99,964 0 144

Intermediate Floors 20000 1,428,947 590 101 35,813 266 51,300 71 336

Exterior Walls 12000 992,333 175 63 21,015 191 22,665 25 302

Windows 0 0 0 0 0 0 0 0 0

Interior Walls 0 0 0 0 0 0 0 0 0

Roof 20000 4,405,157 225 117 58,468 335 42,132 5 914

TOTALS 8,760,105 1,693 405 166,307 1,067 237,349 211 2,079

CO

NC

RET

E VS

. STE

EL

ENVIRONMENTAL IMPACT SUMMARY –CONCRETE CONSTRUCTION

Assembly Total area Fossil Fuel Consumpt.

(MJ) TOTAL

Weighted Resource

use (tonnes) TOTAL

GWP (tonnes CO2 eq) TOTAL

Acidification Potential (moles of H

+ eq) TOTAL

HH Respiratory

Effects Potential (kg PM2.5 eq) TOTAL

Eutrophication

Potential (g N eq) TOTAL

Ozone Depletion Potential

(mg CFC-11

eq) TOTAL

Smog potential (g NOx

eq) TOTAL

Foundations & Footings 20000 532,998 581 68 26,524 161 21,288 109 383

Columns and Beams 40000 2,273,849 1,053 167 67,127 388 162,579 198 735

Intermediate Floors 20000 1,081,422 851 117 47,221 347 37,693 183 701

Exterior Walls 12000 3,758,182 662 280 76,860 436 113,229 223 1,051

Windows 0 0 0 0 0 0 0 0 0

Interior Walls 0 0 0 0 0 0 0 0 0

Roof 20000 4,099,144 599 129 66,871 404 32,761 117 1,166

TOTALS 11,745,595 3,746 761 284,604 1,737 367,551 832 4,037

ENVIRONMENTAL IMPACT SUMMARY – STEEL CONSTRUCTION

Assembly Total area Fossil Fuel Consumpt.

(MJ) TOTAL

Weighted Resource

use (tonnes) TOTAL

GWP (tonnes CO2 eq) TOTAL

Acidification Potential (moles of H

+ eq) TOTAL

HH Respiratory

Effects Potential (kg PM2.5 eq) TOTAL

Eutrophication

Potential (g N eq) TOTAL

Ozone Depletion Potential

(mg CFC-11

eq) TOTAL

Smog potential (g NOx

eq) TOTAL

Foundations & Footings 20000 532,998 581 68 26,524 161 21,288 109 383

Columns and Beams 40000 1,400,670 123 56 24,486 114 99,964 0 144

Intermediate Floors 20000 1,428,947 590 101 35,813 266 51,300 71 336

Exterior Walls 12000 992,333 175 63 21,015 191 22,665 25 302

Windows 0 0 0 0 0 0 0 0 0

Interior Walls 0 0 0 0 0 0 0 0 0

Roof 20000 4,405,157 225 117 58,468 335 42,132 5 914

TOTALS 8,760,105 1,693 405 166,307 1,067 237,349 211 2,079

CO

NC

RET

E VS

. STE

EL

1.3X 2.2X 1.9X 1.7X 1.6X 1.5X 3.9X 1.9X

Alternatives to a Full LCA

•  Environmental product labels.

ISO has established standards for three types of labels:

Type I - the most common type of label in today’s market. Require third party certification of a pre-set list of criteria for issues such as recycled content, VOC’s, and bio-degradability. Type II - provide criteria for self-declarations by a materials extraction organization (mining, for example), manufacturer or supplier. There is no third party review in Type II labels. Type III - require the rigorous use of life cycle environmental information, an open consultation process, and ease of comparison among products. Type III labels are similar to consumer nutrition labeling on food products.

ISO Environmental Labeling Standards

ISO has established standards for three types of labels:

Type I - the most common type of label in today’s market. Require third party certification of a pre-set list of criteria for issues such as recycled content, VOC’s, and bio-degradability. Type II - provide criteria for self-declarations by a materials extraction organization (mining, for example), manufacturer or supplier. There is no third party review in Type II labels. Type III - require the rigorous use of life cycle environmental information, an open consultation process, and ease of comparison among products. Type III labels are similar to consumer nutrition labeling on food products.

ISO Environmental Labeling Standards

ISO has established standards for three types of labels:

Type I - the most common type of label in today’s market. Require third party certification of a pre-set list of criteria for issues such as recycled content, VOC’s, and bio-degradability. Type II - provide criteria for self-declarations by a materials extraction organization (mining, for example), manufacturer or supplier. There is no third party review in Type II labels. Type III - require the rigorous use of life cycle environmental information, an open consultation process, third party review, and ease of comparison among products. Type III labels are similar to consumer nutrition labeling on food products.

ISO Environmental Labeling Standards

Alternatives to a Full LCA

•  Environmental product labels. - ISO Type I – 3rd party, single

attribute.

- ISO Type II – self declaration.

- ISO Type III – LCA-based, multiple attribute, 3rd party verified information.

Environmental Product Declaration

Environmental Product Declarations

Environmental Product Declaration (EPD) An EPD provides consistent and comparable information to industrial customers and end-use consumers regarding environmental impacts.

Product category rules define how information is to be collected and how measurements are to be made.

Environmental Product Declarations

•  LCA - based •  Disclose quantified life cycle data for a product. •  Must clearly state the life cycle stages and product components covered. • Third party verified

Organization for Implementation

Product Category Rules

Tests, Certificates, Other information

EPD Publication

Life Cycle Assessment

Verification by independent third party

Development of an EPD

EPD Draft

Input from producers, LCA experts, testing institutes, NGOs, consumer orgs.

Product description Light Gauge Steel profiles are cold-formed profiles that are used to construct the bearing walls, flooring and roof panels of a building. Declaration is based on aver- aged thickness of cold-formed steel profiles prepared according to a design specification of a building. Application Light Gauge Steel profiles from hot-dip galvanized steel are used in construction industry as well as many other applications: roofing (roofing sheets, roof tiles), cladding (Trapezoidal sheets, sandwich panels, wall cassettes), interior trim (trapezoidal sheets, sandwich panels, wall cassettes), flat sheets (covers, structural panels, wall connections, facing roof), roof drainage systems (gutters, downspouts, soffit boards and accessories), Automotive (vehicles, trailers, refrigeration units), white and brown goods. Typical applications of steel profiles are: - Detached houses, - Villas, vineyard huts, - School and dormitory buildings, - Commercial buildings, - Factory buildings.

Publisher Institut Bauen und Umwelt e.V. Tel. +49 (0)2223 2966 79- 0 Rheinufer 108 Fax +49 (0)2223 2966 79- 0 53639 Königswinter E-mail [email protected] Germany Web www.bau-umwelt.com

Programme holder Institut Bauen und Umwelt e.V. Tel. +49 (0)2223 2966 79- 0 Rheinufer 108 Fax +49 (0)2223 2966 79- 0 53639 Königswinter E-mail [email protected] Germany Web www.bau-umwelt.com

Owner of the Declaration Akkon Steel Structure Systems Co Tel. +90 0282 726 76 90 Çerkezköy Organize Sanayi Bölgesi, Fax: +90 0282 726 77 41 GMKP Mah Atatürk Caddesi No:134, Çerkezköy, Tekirdağ E-mail: [email protected] Turkey Web www.akkoncelik.com

Author of the Life Cycle Assessment Metsims Sustainability Consulting Tel. +90 534 499 32 40 Veko Giz Plaza, Meydan Sk. No:3 K.13 Fax: +90 212 705 36 36 34396 Maslak İstanbul E-mail: [email protected] Turkey Web www.metsims.com

lumber. This EPD was developed in compliance with ISO 14025 and ISO 21930 and has been verified under UL Environment’s EPD program. The EPD includes Life-Cycle Assessment (LCA) results for all processes up to the point that planed and dry lumber is packaged and ready for shipment at the manufacturing gate; the cradle-to-gate product system includes forest management, logging, transportation of logs to lumber mills, sawing, kiln-drying, and planing.

F. INTERIOR WALLS

Assembly Type

Fossil Fuel Consumpt. per ft.2 (MJ)

Weighted Resource

use per ft.2

(mt)

GWP per ft.2 (mt CO2

eq)

Acidification

Potential per ft.2 (moles

of H+ eq)

HH Respiratory

Effects Potential

per ft.2 (kg PM2.5 eq)

Average across interior walls 46.29 3.05 0.96 21.91 884 2x4 Wood Stud Wall 16” o.c. 5/8” gypsum board + 2 coats latex paint 29.28 1.33 0.45 19.08 587.77 2x4 Wood Stud Wall 24” o.c. 5/8” gypsum board + 2 coats latex paint 28.84 1.30 0.44 18.88 544.43 2x4 Wood Stud Wall 16” o.c. 2 x 5/8” gypsum board + 2 coats latex paint 41.00 2.10 0.74 20.68 912.41 1 5/8” x 3 5/8” Steel Stud Wall 16” o.c. 5/8” gypsum board + 2 coats latex paint 36.58 1.89 0.58 19.08 789.19 1 5/8” x 3 5/8” Steel Stud Wall 24” o.c. 5/8” gypsum board + 2 coats latex paint 34.32 1.72 0.54 18.88 695.32 1 5/8” x 3 5/8” Steel Stud Wall 24” o.c. 2 x 5/8” gypsum board + 2 coats latex paint 46.49 2.52 0.83 20.68 1063.30 6” Concrete Block 5/8” gypsum board + 2 coats latex paint 81.72 6.88 1.82 35.98 1673.64

6” Concrete Block 2 coats latex paint 69.56 6.08 1.53 34.18 1305.66

F. INTERIOR WALLS

Assembly Type

Fossil Fuel Consumpt. per ft.2 (MJ)

Weighted Resource

use per ft.2

(mt)

GWP per ft.2 (mt CO2

eq)

Acidification

Potential per ft.2 (moles

of H+ eq)

HH Respiratory

Effects Potential

per ft.2 (kg PM2.5 eq)

Average across interior walls 46.29 3.05 0.96 21.91 884 2x4 Wood Stud Wall 16” o.c. 5/8” gypsum board + 2 coats latex paint 29.28 1.33 0.45 19.08 587.77 2x4 Wood Stud Wall 24” o.c. 5/8” gypsum board + 2 coats latex paint 28.84 1.30 0.44 18.88 544.43 2x4 Wood Stud Wall 16” o.c. 2 x 5/8” gypsum board + 2 coats latex paint 41.00 2.10 0.74 20.68 912.41 1 5/8” x 3 5/8” Steel Stud Wall 16” o.c. 5/8” gypsum board + 2 coats latex paint 36.58 1.89 0.58 19.08 789.19 1 5/8” x 3 5/8” Steel Stud Wall 24” o.c. 5/8” gypsum board + 2 coats latex paint 34.32 1.72 0.54 18.88 695.32 1 5/8” x 3 5/8” Steel Stud Wall 24” o.c. 2 x 5/8” gypsum board + 2 coats latex paint 46.49 2.52 0.83 20.68 1063.30 6” Concrete Block 5/8” gypsum board + 2 coats latex paint 81.72 6.88 1.82 35.98 1673.64

6” Concrete Block 2 coats latex paint 69.56 6.08 1.53 34.18 1305.66

Health Product Declarations

Health Product Declarations The Health Product Declaration Standard was originally developed by the HPD Working Group in collaboration with the Healthy Building Network and Building Green.

It is now managed by the HPD Collaborative.

Health Product Declarations

-  HPDs describe product content and direct health hazards associated with human exposure to the individual components of a product. -  An HPD is not an assessment of risks associated with

actual use of a product. -  An HPD does not address potential health impacts of substances used or created during manufacture. - An HPD is not a full assessment of environmental impacts from the life cycle of a product.

Health Product Declarations

-  An HPD differs from a MSDS:

o  A MSDS provides information about how to work with a hazardous substance or product in a safe manner. Focus is acute health risks:

•  Physical data – melting point, boiling point, flash point) •  Other information – toxicity, health effects, first aid, storage, disposal, protective clothing, spill handling, etc.)

o  An HPD aims for 100% disclosure of all ingredients: •  If hazardous, must be reported much as in MSDS. •  Also provides information as to long-term, chronic exposure.

Awarding of Points within LEED v4

LEED v.4 and LCA Building life-cycle impact reduction (5 pts. possible)

-  Historic building reuse (5 pts), or

-  Renovation of abandoned or blighted building (5 pts), or

-  Building and materials reuse (2-4 pts), or

LEED v.4 and LCA Building life-cycle impact reduction (5 pts. possible)

-  Historic building reuse (5 pts), or

-  Renovation of abandoned or blighted building (5 pts), or

-  Building and materials reuse (2-4 pts), or

-  Whole building life cycle assessment (3 pts)

LEED v.4 and LCA Building life-cycle impact reduction (5 pts. possible) -  Whole building life cycle assessment (3 pts)

•  New construction (bldgs or portions of bldgs) •  LCA must demonstrate a minimum 10% reduction,

compared to a baseline building:

LEED v.4 and LCA Building life-cycle impact reduction (5 pts. possible) -  Whole building life cycle assessment (3 pts)

•  New construction (bldgs or portions of bldgs) •  LCA must demonstrate a minimum 10% reduction,

compared to a baseline building: §  GWP (required) And, at least two of the following: §  Stratospheric ozone depletion §  Acidification potential §  Eutrophication potential §  Formation of tropospheric ozone §  Depletion of nonrenewable energy resources

LEED v.4 and EPDs Building product disclosure and optimization – environmental product declarations (2 pts. possible) -  Use at least 20 different permanently installed products

sourced from at least 5 different manufacturers that meet one of the following disclosure criteria:

•  EPDs (1 point) - Industry-wide (generic) EPD where the product manufacturer is a participant. (counted as ½ of a product in credit calculation) - Product-specific EPD where the product manufacturer is the participant.

•  Second point is gained for optimization

LEED v.4 and EPDs Building product disclosure and optimization – environmental product declarations (2 pts. possible) -  Use at least 20 different permanently installed products

sourced from at least 5 different manufacturers that meet one of the following disclosure criteria:

•  EPDs (1 point) - Industry-wide (generic) EPD where the product manufacturer is a participant. (counted as ½ of a product in credit calculation) - Product-specific EPD where the product manufacturer is the participant.

Clarification being sought

LEED v.4 and EPDs Building product disclosure and optimization – environmental product declarations -  Use at least 20 different permanently installed products

sourced from at least 5 different manufacturers that meet one of the following disclosure criteria:

•  Product specific declarations. (1 point) Products for which there is a publicly available, critically reviewed (ISO 14044) assessment of at least cradle to gate scope (counted as ¼ of a product in credit calculation).

AND/OR . . .

LEED v.4 and EPDs Building product disclosure and optimization – environmental product declarations (must comply with one of criteria below for 50% by cost of total value of permanently installed product)

•  Third-party certified products that demonstrate impact reduction below industry average in at least 3 of the following categories: §  GWP §  Stratospheric ozone depletion §  Acidification potential §  Eutrophication potential §  Formation of tropospheric ozone §  Depletion of nonrenewable energy resources

LEED v.4 and HPDs Building product disclosure and optimization – material ingredients (2 pts. possible) -  Material ingredient reporting. (1 pt.)

Use at least 20 different permanently installed products sourced from at least 5 different manufacturers that meet one of a number of specified programs to demonstrate the chemical inventory of a product to at least 0.1% (1000 ppm)

•  Manufacturer inventory (complete, public, CASRN) •  Health product Declaration •  Cradle to Cradle certification at Basic or Bronze level

LEED v.4 and HPDs Building product disclosure and optimization – material ingredients -  Material ingredient optimization. (1 pt)

Use products that document their material ingredient optimization using various identified paths* for at least 25% of the cost of the total value of permanently installed products in a project.

* Green Screen, Cradle to Cradle Certified, REACH Optimization

LEED v.4 and HPDs Building product disclosure and optimization – material ingredients -  Product mfg supply chain optimization (1 pt). Products are sourced from manufacturers that engage in validated safety, health, hazard, and risk programs and that also document at least 99% (by weight) of product ingredients, and that have independent 3rd party verification of their supply chain with respect to a number of measures.

Use of Wood Products and LEED v4

Wood Use and LEED v4

•  Specification of wood contributes to about 10% of points in various standards. •  Opportunities for achievement of points through specification of wood products include:

o  Building life cycle impact reduction (3 pts) o  EPDs (1-2 pts) o  Sourcing of raw materials (1-2 pts)

- annual CSR report - FSC certified wood - recycled content, reused

o  Material Ingredients – unfinished, untreated (1 pt)

Wood Use and LEED v4

• Opportunities for achievement of points through specification of wood products include:

o  Low-emitting materials – no or low formaldehyde (1-2 pts)

o  Reclaimed materials (1/2 pt) – multifamily midrise only (products made from felled, diseased, or dead trees from urban or suburban areas)

In principal wood producing areas, high potential for achieving locally sourced multiplier.

Summary

•  A number of changes have been made to LEED in the latest version of the standard. •  The most substantial changes have occurred in the Materials and Resources section. •  Environmental impacts of materials and products cannot be accurately determined through intuition. •  Life cycle analysis (LCA) performed in

accordance with international protocols facilitates accurate determination of environmental impacts and product comparisons.

Summary

•  LCA-based EPDs provide reliable information regarding product attributes. Product comparisons difficult. •  HPDs provide complete information regarding

chemical ingredients. Too much information?? • Wood use can contribute to about 10% of total

LEED v4 credits.

This concludes The American Institute of Architects Continuing

Education Systems Course

Jim Bowyer [email protected] Dovetail Partners, Inc. www.dovetailinc.org

Questions?