7
2019 Private mold, unique design AC120-277V/AC120-347V/AC277-480V optional Seoul SMD LED High ec acy, 145lm/w Die-casting aluminum housing, treated by anodic oxidation, anti-corrosion Hollow heat sink design increase more airflow for better heat dissipation IP66 rated, IK10, Surge protect on 10KV/20KV optional Photocell, Microwave, PIR sensor available Slip Filter, Square pole, Round pole,Trunnion, Wall mount adaptor. Environment temperature: -40~ 455 years warranty Applicaon: • Parking lot • Stadiums • General road lighng • Residenal area • Yard park • Petrol staon Features LED SHOEBOX LIGHT LISTED E357402 120-277V 5 YEARS A R N R T A Y W 145 LM/W

LED SHOEBOX LIGHT · 2020. 5. 5. · LED SHOEBOX LIGHT LISTED E357402 120-277V 5 YEARS RRAN A T W Y 145 LM/W. Parameters Beer for heat sink;Water can drain in the rainy days Two holes

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LED SHOEBOX LIGHT · 2020. 5. 5. · LED SHOEBOX LIGHT LISTED E357402 120-277V 5 YEARS RRAN A T W Y 145 LM/W. Parameters Beer for heat sink;Water can drain in the rainy days Two holes

◆ 2019 Private mold, unique design◆ AC120-277V/AC120-347V/AC277-480V optional◆ Seoul SMD LED◆ High effic acy, 145lm/w◆ Die-casting aluminum housing, treated by anodic

oxidation, anti-corrosion◆ Hollow heat sink design increase more airflow for

better heat dissipation◆ IP66 rated, IK10, Surge protect on 10KV/20KV

optional◆ Photocell, Microwave, PIR sensor available◆ Slip Filter, Square pole, Round pole,Trunnion, Wall

mount adaptor.◆ Environment temperature: -40℃~ 45℃◆ 5 years warranty

Applica�on:

• Parking lot

• Stadiums

• General road ligh�ng

• Residen�al area

• Yard park

• Petrol sta�on

Features

LED SHOEBOX LIGHT

LISTEDE357402

120-277V

5YEARS

AR NR TA YW

145 LM/W

Page 2: LED SHOEBOX LIGHT · 2020. 5. 5. · LED SHOEBOX LIGHT LISTED E357402 120-277V 5 YEARS RRAN A T W Y 145 LM/W. Parameters Beer for heat sink;Water can drain in the rainy days Two holes

Parameters

Be�er for heat sink;Water can drain in the rainy days

Two holes in middle

Type III, Type V, 90°op�onal

Lens

Laser nameplate, will not be destroyed even bad weather

Label

Installed at the middle of the front side

Microwave sensor

Type A, Type B, Type C, Type D op�onal

Installa�on Arm

bare board, good heat radia�onSeparated driver design and easy to open and wiring

LED driver

Can be used for AC120-277V onlyNon-removable

Photocell (Edge)

Can be used for AC120-277V/AC120-347V/AC277-480V

Photocell (top)

EPA

Page 3: LED SHOEBOX LIGHT · 2020. 5. 5. · LED SHOEBOX LIGHT LISTED E357402 120-277V 5 YEARS RRAN A T W Y 145 LM/W. Parameters Beer for heat sink;Water can drain in the rainy days Two holes

Accessories

Type A

Slip Fi�er

Type B

Slip Fi�er+Extruded Arm

Type C

Extruded Arm

Type D

Surface Mount Arm

Photocell(Top) Photocell (Edge) Microwave Sensor

BUG RATING

Page 4: LED SHOEBOX LIGHT · 2020. 5. 5. · LED SHOEBOX LIGHT LISTED E357402 120-277V 5 YEARS RRAN A T W Y 145 LM/W. Parameters Beer for heat sink;Water can drain in the rainy days Two holes

Dimension

B

C

A

Size

100W/ 150W

200W

250W/ 320W

Power

13.92"

16.54"

20.49"

A B C

10.65"

12.6"

12.6"

2.36"

2.46"

2.46"

90°Type III Type V

Photometric

IP66 rated, suitable for wet loca�ons

Page 5: LED SHOEBOX LIGHT · 2020. 5. 5. · LED SHOEBOX LIGHT LISTED E357402 120-277V 5 YEARS RRAN A T W Y 145 LM/W. Parameters Beer for heat sink;Water can drain in the rainy days Two holes

2. Connect the input wire and install the lamp on the lamp post

Note: a�er lengthening the input wire, meet the height requirement of

the light pole and connect the wire at the bo�om of the light pole.

Type A (Slip Fi�er )

Installa�onALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!

screw

1. A�ach the lamp arm to the lamp first

Lamp Lamp

light polelight pole

IK10 rated

Passing the tes�ng at -40°C, can be used at cold area

Page 6: LED SHOEBOX LIGHT · 2020. 5. 5. · LED SHOEBOX LIGHT LISTED E357402 120-277V 5 YEARS RRAN A T W Y 145 LM/W. Parameters Beer for heat sink;Water can drain in the rainy days Two holes

Type B (Slip Fi�er+Extruded Arm) & Type C (Extruded Arm)

screw

screw

1. First install the lamp arm in the

proper posi�on of the lamp pole

2. Install the light fixture on the lamp arm 3. Lower cover of the lamp arm is opened and

Complete wiring at handhole on pole.

Use suitable Listed water proof cord bushing

and outlet box cover.

Type D (Surface Mount Arm)

1. First install the lamp arm in the

proper posi�on of the lamp pole

2. Install the light fixture on the lamp arm 3. Lower cover of the lamp arm is opened and

Complete wiring at handhole on pole.

Use suitable Listed water proof cord bushing

and outlet box cover.

Carton Dimension

Package Info.

16.02 ’’*12.48’’*4.8’’

22.52’’*14.25’’*5.39’’

Qty / Carton

1PCS

1PCS

N.W

11.68lbs

20.26lbs

G.W

13.49Ibs

22.51lbs

20GP

1528PCS

848PCS

40HQ

4203PCS

2332PCS

Model

80W

100W

150W

200W

250W

320W

18.58’’*14.25*5.39’’ 1PCS 15.43lbs 17.20lbs 1025pcs 2820pcs

light poleLamp light pole

light pole

light pole

screw

screw

Lamp

Page 7: LED SHOEBOX LIGHT · 2020. 5. 5. · LED SHOEBOX LIGHT LISTED E357402 120-277V 5 YEARS RRAN A T W Y 145 LM/W. Parameters Beer for heat sink;Water can drain in the rainy days Two holes

Safety Precau�onTo reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other

hazards read all warnings and instruc�ons included with and on the fixture box and all fixture labels.

Before installing, servicing, or performing rou�ne maintenance upon this equipment, follow these general precau�ons.

Commercial installa�on, service and maintenance of luminaires should be performed by a qualified licensed electrician.

For The installa�on: If you are unsure about the installa�on or maintenance of the luminaires, consult a qualified licensed electrician

and check your local electrical code.

To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installa�on.

WARNING: RISK OF FIRE OR ELECTRICAL SHOCK

Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.

Turn off the power when you perform any maintenance.

Verify that supply voltage is correct by comparing it with the luminaire label informa�on.

Make all electrical and grounded connec�ons in accordance with the Na�onal Electrical Code and any applicable local code

requirements.

All wiring connec�ons should be capped with UL approved wire connectors.

CAUTION: RISK OF INJURY

Avoid direct eye exposure to the light source while it is on.

Account for small parts and destroy packing material, as these may be hazardous to children.

SUITABLE FOR DRY OR DAMP LOCATION

Installa�on Arm

Slip Fi�er

Slip Fi�er+Extruded Arm

Extruded Arm

Surface Mount Arm

Carton Dimension

24.53’’*16.77’’*8.7’’

24.53’’*19.96’’*10.83’’

21.77’’*19.96’’*10.83’’

22.32’’*20.16’’*6.5’’

Qty / Carton

12PCS

12PCS

12PCS

12PCS