Leadscrew taskforce report
L. GentiniFrancois-Xavier Nuiry, Inigo Lamas, Jerome Lendaro, Manuele Narduzzi, Maxime
Bergeret, Mickael Crouvizier, Patrice Francon, Pierre Gander.
HiColDem8th November, 2018
EDMS: 1760258
08-11-2018
2
DRY SCREW TESTED
UMBRA: Recirculating ball screws
Screw and nut in St. Steel + ceramic balls
Screw and nut in St. Steel + ceramic / St. Steel balls
KSK: Recirculating ball screws
Screw and nut in St. Steel + St. Steel balls
SKF: Recirculating roller screws
Screw and roller in St. steel with Dicronite coating nut in St. steel
KUGEL MOTION: Recirculating roller screws
Screw and nut in St. steel with Dicronite coating
ROLLVIS: Satellite roller screws
Screw and nut in St. steel with WC/C and Rollers in St. Steel with WC/C + Dicronit coating
Luca Gentini– EN-MME08-11-2018
Supplier Max number of cycles
UMBRA 1050
KSK 150
SKF 3300
Kugel motion 907
ROLLVIS 35000
3Luca Gentini– EN-MME08-11-2018
SCREW MOVEMENTS
Recirculating ball screws
Recirculating roller screws
Satellite roller screws
4Luca Gentini– EN-MME08-11-2018
ROLLVIS SCREW TEST PARAMETERS
• Cycle profile: same of the LHC but faster
• Screw assembled on the upper position (1.4 kN max)
• Each 10.000 cycles the screws is dismounted for a visual test
• Check manually the play
• Microscope pictures
• A new servo-type motor drive developed by EN-SMM used:
• Monitoring the current, we calculate the proportional torque.
• Smoother motion due to dumping of the oscillatory open loop dynamics.
• Less vibrations, less noise and less wear.
• Data acquisition every 100 cycles (55 sec)
5Luca Gentini– EN-MME08-11-2018
ROLLVIS SCREW TEST RESULTS
Typical acquisition
6Luca Gentini– EN-MME08-11-2018
ROLLVIS SCREW TEST RESULTS
Average current of each acquisition (350) on 35000 cycles
Part 1
Part 2
Part 3
7Luca Gentini– EN-MME08-11-2018
ROLLVIS SCREW TEST RESULTS
Maximum current of each acquisition (350) on 35000 cycles
The current has reached around 1500 mA, whereas the maximum current that the motor can handle is about 2800 mA. Thus, we are at 50% of the maximum current/torque that the motor can provide.
8Luca Gentini– EN-MME08-11-2018
ROLLVIS SCREW TEST RESULTS
Digital microscope analysis shows a wearing of the screw threat. But no motor steps lost and the functionality of the screw is still respected.
Rusty sideSafe side
9Luca Gentini– EN-MME08-11-2018
ROLLVIS SCREW TEST RESULTS
The cycled screws seams totally oxidized
Rusty sideSafe side
10
On-going Actions
• ROLLVIS cycled screw has been sent to rollvis to be dismounted and analyzed
• ROLLVIS experts will come at CERN to make conclusion after analysis.
• A second Rollvis is now cycling on the bottom side of the mechanical table (2 kN -~400mA more)
• For the TDIS, because of UMBRA delivery late, a lubricated rollvis screw has been ordered. On this screw a quick lubrication system will be embarked. No coating required whit lubricant. Possibility to modify mechanical table components to use the same system everywhere.
Luca Gentini– EN-MME08-11-2018
11
Conclusion / Open points
• The only screw which reached the target is ROLLVIS. The others are far away.
• Can be the difference attribute to the screw system?
• Do we want to test others screws whit the same system?
• Other cycling test are on-going on ROLLVIS for statistic, but even if others screws have same results, are the ROLLVIS screw approved as a dry solution?
• If we want to have a combined solution (lubricated screw with quick lubrication which can works whit-out lubricant for a lap of time) can we test a ROLLVIS dry screw without-out coating?
Luca Gentini– EN-MME08-11-2018
Thanks for your attention