Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
Engineering
Evaluation
Designing
Manufacturing
Testing
Execution
Post Sales & Service
TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS
TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS
ACOUSTIC HOODS | ENCLOSURES
PACKAGE BLOWER SYSTEMS
EVEREST PRESSURE & VACUUM SYSTEMS
Leading the way for INNOVATIVE SOLUTIONS
Engineering | Evaluation | Designing | Manufacturing | Testing | Execution | Post Sales & Service
Water Treatment Plants for backwashing of filter/mixed beds
Effluent Treatment Plants for diffused aeration and agitation of effluent
Sewage Treatment Plants for diffused aeration and agitation of sewage
Cement Plants for blending, aeration, fluidization and conveying
Aquaculture for maintaining the dissolved oxygen level
Chemical Plants for supply of process air
Electroplating Plants for oil free air agitation of electrolyte
Paper Plants for knife edge coating, drying, conveying and vacuum pickup
Yarn Drying for vacuum/pressure drying
Polyester Chip Conveying & Drying for transfer of polyester chips and other similar materials
Bag Filters for reverse cleaning of filter bags
Pneumatic Conveying for vacuum, pressure and combination conveying of cereals, cement, husk, baggase,
granules, powders and other similar material
Regeneration of Dryers & Molecular Sieves
FGD - Flue Gas Desulpharization
VPSA - Vacuum Pressure Swing Adsorbtion
APPLICATIONS
Customer SupportT: +91 11 4545 7740 | E: [email protected]
EVEREST PRESSURE & VACUUM SYSTEMS
Corporate OfficeB-44, Mayapuri Industrial Area, Phase1, New Delhi 110 064, IndiaT: +91 11 4545 7777 | E: [email protected]
Group Companies
Everest Blowers Private Limited | Everest Blower Systems Private Limited
www.everestblowers.comPackage Blower Systems | Revision 2 |May 2017
Works:Plot No. 82-83, Sector 16, HSIIDC, Bahadurgarh 124507, Haryana, IndiaT: +91 1276 241281, 241282, 241383
Provider of Innovative engineering solutions in entire range of pressure & vacuum systems by having state of art technology, optimized designs, excellence in R&D, manufacturing and thrust on training & development of employees, continuously expanding our operations.
To become top solution provider of Pressure & Vacuum Systems in India, setting benchmarks of performance and providing value for customers.
We at Everest are committed to continually improve in all process areas leading to quality product by involving competent and motivated employees at all levels leading to overall growth of the company through satisfied customers.
• Delivery on time, delivery in full, of defect free products
• Wastage reduction• Introducing New/
upgraded products better than the competitor, meeting customers' expectations
• Cost reduction by Value Engineering/ other methods
• Timely and effective customer support & services
• Achieving and sustaining superior levels of performance in all operations
• Up gradation of infrastructure
• Human resources development
• Customer Focus• Respect for Individuals• Integrity• Strong Relationships• Passion & Drive• Institution Building• Working Together
Mission Vision Quality Policy Quality Objectives Core Values
EVEREST PRESSURE & VACUUM SYSTEMS
Leading the way for INNOVATIVE SOLUTIONS
Everest Group
Engineering
Evaluation
Designing
Manufacturing
Testing
Execution
Post Sales & Service
EVEREST PRESSURE & VACUUM SYSTEMS
Leading the way for INNOVATIVE SOLUTIONS
EVEREST commenced manufacturing of Twin Lobe Rotary Air Blowers
way back in 1980. Since then the company has consistently strengthened
its manufacturing base, producing a wide range of products. This broad
product line includes Twin Lobe & Tri-Lobe Rotary Air Blowers / Compressors
(Roots Blowers), Mechanical Vacuum Boosters, Dry Screw Vacuum Pumps, Acoustic
Hoods & Industrial Vacuum Systems. These wide-ranging products and the technical
expertise gained over the years have enabled Everest to serve various segments of
industry such as water treatment plants, effluent treatment plants, cement plants,
aquaculture farms, chemical & pharmaceutical plants, food processing units, waste oil
re-refining units, paper plants, vacuum plants and systems and pneumatic conveying
systems.
The blowers find use in applications requiring medium pressure air such as aeration
in sewage treatment and effluent treatment plants, filter backwash, agitation of
electrolyte, pneumatic conveying, regeneration of dryers & molecular sieves,
maintaining BOD of water etc.
The mechanical vacuum booster & Dry Screw Vacuum Pumps, a sophisticated piece
of machinery developed by the company, finds use in chemical and pharmaceutical
processes, bulb and tube light production, waste oil re-refining, roll and object
metallizing, vegetable oil deodorization, solvent recovery, vacuum drying, tray
drying, vacuum distillation, thin film deposition, molecular distillation, vacuum
furnace, transformer oil dehumidification, chemical laser, evaporative cooling etc.
Apart from above standard products Everest is also into a lot of customized products
which include various specialized equipment to meet the specific demands such as
Canned Motor Mechanical Vacuum Boosters especially developed for BARC for
research applications, Helium and CO duty blowers for Nuclear Power 2
Corporation, Petrol engine driven aluminium alloy blowers for thermit welding of
rails for Indian Railways, 100% Oil Free blowers for fish and prawn culture, etc.
Everest is also into supply of complete systems for special applications such as
Vacuum Distillation, Vacuum Drying (Vacuum Tray Dryers, Rotary Cone Vacuum
Dryers, etc), Solvent Recovery, Waste Oil Re-refining etc. which are commonly used
in Food Processing, Pharmaceutical & Chemical Industries. Everest also offers 100%
Dry Vacuum Systems having no requirement of Steam, Water or Oil. This leads to
zero effluent / zero discharge of any harmful gases inside the plant, thus maintaining
high level of product quality and maintaining pollution free environment.
Some of our prestigious clients include NIOT, Indian Space Research Organization,
Centre for Advanced Technology, BARC, Mishra Dhatu Nigam, NTPC, Ion
Exchange (India) Ltd., Thermax, Aurobindo Pharma, KLJ, Wockhardt, VA Tech
Wabag, Maruti Udyog, Honda Siel, Hero Honda, Grasim Industries, Cadbury, LG
Polymers, Heinz, Vam Organics, Smithklime Beecham, Cipla, DSM, Hereto Drugs,
IOCL, GAIL, EIL, BHEL, Grasim, ACC, Tata Steel, Jindal Steel, McNally Bharat,
Jindal Saw and many more.
We are concentrating more on application engineering and in helping our
customer's save on their processes. This innovation has not only compensated on our
general sales but even helped us to outperform on our targets. Our application
oriented R&D has made it possible to cover wider areas of applications, offering cost
effective and energy efficient solutions thus creating larger market demand for our
product.
A focus on innovative design and high quality machined parts has earned Everest a
reputation for excellent workmanship amongst its users. For more than three
decades Everest has offered its customers quality, cost-effective machines necessary to
meet the changing technology. Our commitment to total quality in both our
products and services is the foundation upon which our future business is based.
Some of Our Recent Achievements
• Design & manufacture of seal less Roots Blowers
• Design & manufacture of solvent recovery systems to curb pollution. These
systems not only play an important role by making the process eco-friendly but
also recover precious solvents for reuse.
• Design & manufacture of CPCB approved systems for waste oil re-refining.
• Design & manufacture of mechanical vacuum boosters for replacement of steam
jet ejectors.
• Design & manufacture of SUPERVAC vacuum systems using mechanical
TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS
TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS
ACOUSTIC HOODS | ENCLOSURES
A focus on
innovative
design and high
quality
machined parts
has earned
Everest a
reputation for
excellent
workmanship
amongst its users.
For more than three
decades Everest has
offered its customers
quality, cost-effective
machines necessary
to meet the changing
technology
ABOUT US
EVEREST PRESSURE & VACUUM SYSTEMS
Leading the way for INNOVATIVE SOLUTIONS
vacuum boosters and dry screw vacuum pumps - Dry Pumping Technology.
• Design & manufacture of extended shaft Roots Blowers for applications
requiring 100% Oil Free Air like aeration in aquaculture farms, plating lines, STPs,
etc.
• Design and manufacture of canned motor mechanical vacuum boosters
• Design & manufacture of India's first MVR (Mechanical Vapour
Recompression) Blower successfully put to use.
• Design & manufacture of Low Temperature Thermal Desalination systems for
producing potable water ……… and many more.
• We have plans of setting up the most modern manufacturing facility with in
house DSIR registered R&D facility which would not only role out good reliable
products but also assist in meeting the targeted expansion program.
Everest is the first and the only Indian Blower manufacturer to have successfully
shifted entire production load of its blowers, boosters & pumps on CNC machines.
The company has imported a number of sophisticated CNC machines from USA &
Japan, resulting in higher production capacities & better quality. Everest is today the
largest Roots Blower manufacturer in the country and a leader in its segment.
Broad Product Line Serves Wide Variety of Applications
We know that performance of the OEM's design ultimately depends on the quality
and dependability of its components. That's why so many manufacturers of Water
Treatment Plants, Effluent Treatment Plants, Cement Plants, Aquaculture Farms,
Chemical Plants, Paper Plants, Vacuum Plants and Systems, and Pneumatic
Conveying Systems have entrusted their reputation to Everest. Our broad product
line of Roots Blowers/Compressors (Bi-lobe & Tri-lobe) (Air/Gas Duty),
Mechanical Vacuum Boosters, Dry Screw Vacuum Pumps, Acoustic Hoods &
Industrial Vacuum Systems consists of standard and custom models that fall into
major product group.
Our Commitment To Quality | ISO 9001:2015
The hallmark of our commitment to quality is our International Standards
Organisation (ISO) registration. This ensures that our OEM customers receive
products of highest quality.
ABOUT US
TIMELINE
1980 Set up 'EVEREST TRANSMISSION' to manufacture Twin Lobe Rotary Air Blowers /Compressors for industries related to cement, chemicals, water & waste water treatment, effluent treatment, electroplating, aqua culture, etc.1985Chosen as a priority vendor by BHEL and entire Quality Management System designed and implemented with the help of Vendor Development Cell of BHEL.1985-1995Bagged prestigious orders from Industry giants like NTPC, Ion Exchange (India) Ltd., Thermax, Bechtel, Daelim, Mitsubishi Heavy Industries, BHEL, Tata Projects, Toyo Engineering, ONGC, Holtec Consultants, IPCL, SGS, Degremont, Driplex, Development Consultants, Grindwell Norton, Triveni Engineering, VA Tech Wabag, etc.1993Import substitute Mechanical Vacuum Booster developed and introduced to Indian market for vacuum metallizing, sputtering, space research, etc.1995Set up 'EVEREST BLOWERS' to cater to the growing demand of small roots blowers up to 15 HP.1998Certified ISO 9001 Quality Management System by DNV, Norway.1999Introduced AQUA Series Air Blowers specially crafted for fish and prawn culture and electroplating applications. New Water Cooled Blower design introduced.2000Met the technical requirements of the Research Cell of Department Of Atomic Energy, CAT, Indore for supply of Mechanical Vacuum Boosters for Chemical Laser Division. Developed Model M450, EB6HPM, & M5 Series Air Blowers.2001Began exporting our Mechanical Vacuum Booster Pumps to advanced countries such as USA, Singapore and Middle East against stiff global competition.2002Dry Vane Pumps introduced and expansion of exports to Singapore, UK, Australia, UAE, Iraq, Maldives, Sri Lanka, Vietnam, Nepal, Bhutan, and Bangladesh.2003EXPO Series Air Blowers developed. 2004Developed Extended Shaft Design Air Blowers. Introduced Mechanical Vacuum Boosters in the Indian Pharmaceutical & Chemical Industry and for waste oil re-refining. Successfully designed, manufactured & supplied vacuum drying systems to Cadbury India Limited.2005Vacuum Systems supplied to National Institute Of Ocean Technology for 0.1 MLD Low Temperature Thermal Desalination (LTTD) Pilot Plant for producing potable water First of its kind in the world. Successfully installed at Kavaratti in Lakshadweep, India. Mechanical Vapor Recompression Systems successfully developed & installed.2006Successfully designed, manufactured & supplied World's First 1 MLD Low Temperature Thermal Desalination (LTTD) system for producing potable drinking water to National Institute of Ocean Technology, Chennai, India. Introduced Back Flow Cooling Rotary Air Blowers for VPSA ( Vacuum Pressure Swing Adsorption) system.2007Set up 'EVEREST BLOWER SYSTEMS' to cater to the demands of Industrial Vacuum Systems & Dry Vacuum Pumping technology.2008Introduced Dry Screw Vacuum Pumps. Introduced Dry Vacuum Pumping Systems for Waste Oil Re-refining.2009Complete manufacturing shifted over to CNC machines imported from Haas, USA. Introduced Everest Super Sucker 4000. Introduced Vacuum Pumping Systems for Solvent Recovery & Vacuum Distillation. Successfully designed, manufactured & supplied vacuum drying systems to Cadbury Nigeria.2010Developed & introduced Vertical Tri-lobe Roots Blower Model ETL025. Introduced Everest Super Sucker 6000.2011Manufacturing facility at Everest Blowers, Bahadurgarh completely revamped for enhanced production capability of 1000 machines per month.2012Tie up with LOT Vacuum, Korea for sales of Dry Screw Vacuum Pumps & Systems for
Semi-Conductor & Solar Industry. Introduced Dry Screw Vacuum Pumps with Hybrid Screw Design. Initiated Business Excellence exercise at Everest Group. Developed & introduced complete range of Tri-Lobe Roots Blowers.2013R&D Facility at Everest Blowers awarded recognition by Department Of Scientific & Industrial Research, Ministry Of Science & Technology, Government Of India. Awarded Delhi Safety Awards 2013 by Government Of National Capital Territory Of Delhi. Manufacturing facility at New Delhi revamped and additional CNC machines added from Haas, USA for capacity enhancement.2014Everest Blowers Systems shifted to new world class facility. Everest Group awarded National Award for Excellence in R&D from Prime Minister of India. Everest Transmission received prestigious orders from Nuclear Power Corporation of India for supply of Helium & Carbon Dioxide Blowers and repeat order from Le Sueur Bioenergy, Minnesota, USA for supply for Bio-gas Blowers. Production capacity enhancement at EBPL with induction of advanced CNC machines from Haas, USA.2015Dealers appointed in Middle East & Singapore for export promotion. New facility procured for Pressure Division. Everest Group plans to come out with a state-of-the-art world class facility for manufacturing of PD Blowers & Mechanical Vacuum Boosters at this facility. Developed new line of Mechanical Vapour Recompressors.2016New world class production facility started for manufacturing of PD Blowers & Mechanical Vacuum Boosters. Everest Group receives National Award for Energy Efficient Pumps. Everest Group introduces High Speed Single Stage Centrifugal Blowers (Turbo Blowers) and Multistage Centrifugal Blowers. Mr. Amit Kapur awarded Everything About Water Hall Of Fame Award. QMS upgraded to ISO 9001:2015 standard.
TWIN-LOBE ROTARY AIR BLOWERS TRI-LOBE ROTARY AIR BLOWERS TRI-LOBE VERTICAL ROTARY AIR BLOWERS TWIN LOBE ROTARY GAS BLOWERS ACOUSTIC HOODS | ENCLOSURES
Engineering | Evaluation | Designing | Manufacturing | Testing | Execution | Post Sales & Service
Package Blower Systems
EVEREST PRESSURE & VACUUM SYSTEMS
Leading the way for INNOVATIVE SOLUTIONS
Industries Served
• Aerospace
• Agriculture
• Fishing Industry
• Timber Industry
• Tobacco Industry
• Aquaculture
• Chemical
• Pharmaceutical
• Construction
• Energy
• Electrical Power
Industry
• Petroleum Industry
• Oil & Gas
• Food Industry
• Dairy
• Food Processing
• Breweries & Distillery
• Manufacturing
• Pulp & Paper
• Steel
• Textiles
• Cement
• Water Industry
Biotechnology
Metals & Mining
FGD - Flue Gas
Desulpharization
VPSA - Vacuum Pressure
Swing Adsorbtion
EVEREST PRESSURE & VACUUM SYSTEMS
Leading the way for INNOVATIVE SOLUTIONS
Effective sealing of
the compressor inlet
area from the
discharge area is
accomplished by
use of very small
operational
clearance,
eliminating the need
of any internal
lubrication of the
lobes. The air
delivered, thus
is 100% OIL
FREE
EVEREST, a leading manufacturer of Roots Blowers in India, offers a complete range of Twin Lobe Rotary Air Blowers (Roots Blowers), available
3 3for flow rates from 25m /hr to 20,000 m /hr in single stage and upto any 2capacity in parallel configuration, for working pressures upto 1 Kg/cm . They are
available as package units, ready to install or as bare blower units for replacement.
WORKING PRINCIPLE
Everest Twin Lobe Rotary Compressors/Blowers are positive displacement units, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs two Twin Lobe impellers mounted on parallel shafts, rotating in opposite direction within a casing closed at the ends by side plates. As the impellers rotate, air is drawn into one side of the casing and forced out of the opposite side against the existing pressures. The differential pressure developed, therefore, depends upon the resistance of the connected system. The Blowers, being positive displacement type, do not develop pressure within the casing but the discharge pressure depends upon the system resistance / back pressure. Effective sealing of the compressor inlet area from the discharge area is accomplished by use of very small operational clearance, eliminating the need of any internal lubrication of the lobes. A pair of accurately machined alloy steel, hardened and ground timing gears maintain clearances between the impellers, during rotation. The air, thus delivered, is 100% OIL FREE. The pumping capacity of a lobe compressor, operating at constant speed remains relatively independent of inlet and discharge pressure variations. These Blowers are constant volume machines, which deliver a fixed discharge against the system back pressure. It is, therefore, essential to ensure that minimum pipeline restrictions, at the inlet and discharge, are imposed. Adequate size piping and large radius bends ensure minimum line losses resulting in higher efficiency and low power consumption. Sudden change in pipeline cross section should also be avoided. To change capacity, it is necessary either to change speed (energy saving) or vent some of the air into atmosphere (not energy saving). The air must not be recirculated from the discharge to suction as it may result in overheating. No attempt should ever be made to control the capacity of compressor by means of throttle valves in the intake or discharge piping. This increases the power load on the motor and may seriously damage the compressor. There is an increase in the discharge air temperature due to
0heat of compression. As a thumb rule the discharge air temperature increases @ 10 C 2 for every 0.1 Kg/cm of P above the inlet temperature.
EVEREST PRESSURE & VACUUM SYSTEMS
Leading the way for INNOVATIVE SOLUTIONS
Engineering | Evaluation | Designing | Manufacturing | Testing | Execution | Post Sales & Service
FEATURESTWIN-LOBE ROTARY AIR BLOWERS
Everest Blowers are
available as
package units,
ready to install
or as bare blower
units for replacement
• 100% oil free air delivery
• Factory engineered, Factory guaranteed, superior product
• Alloy steel hardened and ground timing gears, oil splash lubricated
• Anti-friction bearings
• Rotary Oil Sealing
• Rigid one piece CI casing & end plates
• Horizontal &V ertical configurations available
• Easy rotor timing setting
• Air Cooled & Water Cooled design available
• Fail safe labyrinth sealing
• Extended shaft design for cool running
• Dynamically balanced rotor shaft assembly (Grade 6.3 ISO 1940-1986)
• Large inlet & outlet connections for minimal loss
• Improved volumetric efficiency and reduced operating temperatures
• Alloy steel toughened shafts ground to close tolerances
• Performance testing as per standard test procedure STP-01 based on BS 1571-2:1975 and ISO 1217:2009
• All blowers are manufactured on state of the art, imported CNC machines, machined to close tolerances with
high degree of accuracy on profile machining, ensuring high volumetric efficiency
• All major components are interchangeable making Everest the first and only manufacturer to attain the same
• Non-contact type labyrinth seals, with vent , offers lifelong sealing without any seal replacement need
TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS
TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS
ACOUSTIC HOODS | ENCLOSURES
44 EVEREST | AIR COOLED
POSITION-1 POSITION-2 POSITION-4POSITION-3
PACKAGE BLOWER SYSTEMS
PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1400
1800
RPM
MODEL M450
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 46 mm; Standard recommended line size: 40 mmNB; Horizontal Flow Configuration; Suitable for Air Duty, Pressure Applications only; Air Cooled Version Only.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
45 0.5 34 0.8 25 1.0 18 1.3 12 1.6 6 1.8 1 2.1
75 0.7 64 1.1 56 1.5 49 1.8 42 2.2 36 2.6 31 3.0
116 1.0 105 1.5 96 2.1 89 2.6 83 3.1 77 3.6 72 4.1
2400
2100
207 2.6 198 3.5 191 4.4 185 5.3 179 6.2 174 7.1
149 5.4 143 6.2
2700 210 7.0 205 8.0
187 1.5 176 2.3 168 3.1 161 3.9 154 4.7
157 1.3 146 2.0 137 2.7 130 3.3 124 4.0 118 4.7 113 5.3
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1400
1800
RPM
MODEL 42
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 52 mm; Standard recommended line size: 40 mmNB; Air Cooled & Water Cooled versions available; Max. Vacuum: 5000 mmWCHorizontal Flow Configuration for Air Duty & Pressure Applications; Vertical Flow Configuration for Gas Duty & Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
47 0.5 37 0.8 30 1.0 23 1.3 17 1.6 12 1.8 7 2.1
78 0.7 68 1.1 60 1.5 54 1.9 48 2.2 43 2.6 38 3.0
119 1.0 109 1.6 102 2.1 95 2.6 89 3.1 84 3.7 79 4.2
2400
2100
212 2.7 204 3.6 198 4.5 192 5.4 187 6.3 182 7.2
156 5.5 151 6.3
2700 213 8.1
191 1.5 181 2.3 174 3.1 167 3.9 161 4.7
161 1.3 150 2.0 143 2.7 136 3.3 130 4.0 125 4.7 120 5.4
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
3
34
75
177
147
116
2.3
3.4
4.7
8.1
7.0
6.0
3.7
5.2
7.8
6.7
4.1
5.7
7.4
29
70
142
112
25
66
108
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1500
1900
RPM
MODEL 44
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 75 mm; Standard recommended line size: 65 mmNB; Air Cooled Version Only; Max. Vacuum: 5000 mmWCHorizontal Flow Configuration for Air Duty & Pressure Applications; Vertical Flow Configuration for Gas Duty & Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
80 0.6 69 1.0 61 1.4 55 1.8 49 2.2 44 2.5 39 2.9
125 0.9 114 1.4 106 2.0 100 2.5 94 3.1 88 3.6 84 4.2
199 1.4 189 2.2 181 3.0 174 3.8 169 4.6 163 5.4 158 6.3
2500
2200
339 3.6 331 5.0 324 6.3 318 7.7
268 8.0
2800
304 2.0 294 3.2 286 4.4 279 5.6 273 6.8
259 1.7 249 2.8 241 3.8 234 4.8 228 5.9 223 6.9 218 7.9
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
349 2.3
394 2.5 384 4.1 376 5.6 369 7.1
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1500
1900
RPM
MODEL 47
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 80 mm; Standard recommended line size: 80 mmNB; Air Cooled Version Only; Max. Vacuum: 5000 mmWCHorizontal Flow Configuration for Air Duty & Pressure Applications; Vertical Flow Configuration for Gas Duty & Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
127 1.1 101 1.8 81 2.5 64 3.2
209 1.6 183 2.6 162 3.6 146 4.6
345 2.4 319 3.9 298 5.4 282 6.8
2500
2200
591 6.5
2800
535 3.5 509 5.7 489 7.9
454 3.0 427 4.9 407 6.8
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
PBHP
617 4.0
698 4.5 672 7.2
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
Q3m /hr
PBHP
A I R C O O L E D
SPEED
700
1500
2000
2400
RPM
MODEL EXPO 1
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 3” BSP; Standard recommended line size: 80 mmNB; Vertical Flow Configuration; Suitable for Air Duty, Pressure Applications only; Air Cooled Version Only.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
62 0.8 45 1.2 31 1.6 20 1.9 10 2.3 1 2.7
182 2.5164 3.4151 4.2140 5.0130 5.8120 6.6112 7.4
257 2.3 239 3.4 226 4.5 214 5.6 204 6.6 195 7.7 187 8.8
3200
2800
419 5.4 405 7.2 394 8.9 384 10.6 375 12.4 366 14.1
315 10.8 307 12.4
3600 435 13.9 426 15.9
376 3.2 359 4.7 345 6.3 334 7.8 324 9.3
317 2.7 299 4.1 286 5.4 274 6.7 264 8.0 255 9.3 247 10.6
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
104
179
359
299
418
239
8.3
9.9
15.9
13.9
17.9
11.9
PBHP
9.1
11.0
17.6
15.4
19.8
13.2
12.1
19.4
16.9
14.5
97
172
351
292
411
232
90
165
344
285
225
436 3.7
496 4.1 478 6.1 465 8.0 454 10.0 444 12.0
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1500
1900
RPM
MODEL M5075
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 75 mm; Standard recommended line size: 80 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
114 1.3 97 1.8 83 2.4 71 3.0 61 3.6 52 4.1 44 4.7
182 1.8 164 2.6 150 3.5 139 4.3 129 5.1 120 5.9 111 6.7
294 2.7 276 4.0 262 5.2 251 6.4 241 7.6 232 8.9 223 10.1
2500
2200
500 6.6 487 8.6 475 10.7 465 12.7 456 14.8 448 16.8
389 13.0 380 14.8
2800 523 16.5 515 18.8
451 4.0 433 5.8 420 7.6 408 9.4 398 11.2
384 3.5 366 5.0 352 6.6 341 8.1 331 9.7 322 11.2 313 12.8
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
36
103
216
440
373
305
5.3
7.5
11.3
18.8
16.6
14.3
PBHP
5.8
8.4
12.5
18.4
15.9
6.4
9.2
13.8
20.2
17.4
29
96
208
365
298
22
89
201
358
291
518 4.5
585 5.1 568 7.4 554 9.7 543 12.0 533 14.2
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1500
1900
RPM
MODEL M5125
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 80 mm; Standard recommended line size: 80 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
147 1.4 124 2.2 107 2.9 92 3.6 79 4.4 67 5.1 57 5.9
234 2.1 211 3.1 194 4.2 179 5.2 166 6.3 154 7.3 143 8.4
378 3.1 356 4.7 338 6.2 323 7.8 310 9.4 298 11.0 288 12.6
2500
2200
644 7.8 627 10.4 612 13.0 599 15.7 587 18.3
501 16.1 490 18.4
2800 674 20.5
581 4.5 558 6.8 540 9.1 526 11.5 513 13.8
494 3.9 471 5.9 454 7.9 439 9.9 426 11.9 414 13.9 403 15.9
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
46
133
278
480
393
6.6
9.4
14.1
20.7
17.9
7.3
10.5
15.7
19.9
8.1
11.5
17.3
37
124
268
384
28
115
259
667 5.1
754 5.7 731 8.7 714 11.6 699 14.6 686 17.5
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1500
1900
RPM
MODEL M5175
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 100 mm; Standard recommended line size: 100 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
206 1.7 174 2.8 150 3.8 129 4.8 111 5.9 94 6.9 79 7.9
327 2.5 295 3.9 271 5.4 250 6.9 232 8.4 216 9.8 200 11.3
530 3.7 498 5.9 473 8.1 453 10.3 434 12.6 418 14.8 403 17.0
2500
2200
902 9.9 878 13.6 857 17.2
2800
813 5.4 781 8.7 756 11.9 736 15.2 718 18.4
691 4.7 660 7.5 635 10.3 614 13.1 596 15.9 580 18.7
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
65
186
389
9.0
12.8
19.2
PBHP
10.0
14.3
11.0
15.7
52
173
39
161
934 6.2
1056 6.9 1024 11.1 999 15.2 978 19.3
1.7
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1400
1800
RPM
MODEL M5225D
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 100 mm; Standard recommended line size: 100 mmNB; Air Cooled version only; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas / Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
286 2.3 246 3.7 214 5.1 188 6.5 165 7.9 144 9.3 125 10.7
451 3.3 410 5.3 379 7.3 353 9.3 330 11.3 309 13.3 289 15.3
670 4.6 630 7.4 599 10.2 572 13.0 549 15.8 528 18.6
2400
2100
1179 12.7 1148 17.5
2700
1055 6.9 1014 11.1 983 15.3 957 19.5
890 5.9 849 9.5 818 13.1 792 16.7 769 20.3
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
1219 7.9
1312 19.7
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1400
1800
RPM
MODEL M5225
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 100 mm; Standard recommended line size: 100 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas / Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
286 2.3 246 3.7 214 5.1 188 6.5 165 7.9 144 9.3 125 10.7
451 3.3 410 5.3 379 7.3 353 9.3 330 11.3 309 13.3 289 15.3
670 4.6 630 7.4 599 10.2 572 13.0 549 15.8 528 18.6
2400
2100
1179 12.7 1148 17.5
2700
1055 6.9 1014 11.1 983 15.3 957 19.5
890 5.9 849 9.5 818 13.1 792 16.7 769 20.3
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
107
271
12.1
17.3
13.5
19.3
14.990
255
74
1219 7.9
1312 19.7
Q3m /hr
PBHP
A I R C O O L E D
SPEED
700
1500
2000
2400
RPM
MODEL EXPO 2
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 4” BSP; Standard recommended line size: 100 mmNB; Vertical Flow Configuration; Suitable for Air Duty & Pressure Applications only; Air Cooled version only.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
144 1.3 117 2.1 97 2.8 80 3.6 65 4.3 52 5.1 39 5.8
380 2.8 354 4.4 334 6.0 317 7.7 302 9.3 288 10.9 276 12.5
528 3.8 502 5.9 482 8.1 465 10.2 450 12.4 436 14.5 424 16.7
3200
2800
857 9.5 837 12.9 820 16.3 805 19.8 791 23.2
673 20.3 660 23.4
3600
765 5.3 738 8.3 718 11.3 701 14.3 686 17.3
646 4.5 620 7.1 600 9.7 583 12.3 568 14.8 554 17.4 542 20.0
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
28
264
412
530
6.6
14.1
18.8
22.6
7.3
15.7
21.0
8.1
17.4
23.1
17
253
401
6
243
391
883 6.0
1001 6.8 975 10.6 955 14.5 938 18.4 923 22.3
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1400
1700
RPM
MODEL EB6HPM
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 85 mm; Standard recommended line size: 100 mmNB; Air Cooled Version Only; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.
188 1.9 158 2.8 134 3.8 115 4.7 97 5.7 82 6.6 67 7.6
300 2.7 270 4.0 247 5.4 227 6.7 210 8.1 194 9.5 179 10.8
450 3.7 420 5.6 396 7.5 376 9.4 359 11.4 343 13.3 329 15.2
2200
2000
719 8.9 695 11.8 676 14.8 658 17.8 643 20.8 628 23.8
568 18.9 553 21.7
2400 717 22.7 703 26.0
674 5.3 644 8.0 621 10.8 601 13.5 583 16.2
562 4.5 532 6.8 508 9.2 489 11.5 471 13.8 456 16.1 441 18.4
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
749 5.9
824 6.4 793 9.7 770 12.9 750 16.2 733 19.5
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1400
1700
RPM
MODEL 67
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 120 mm; Standard recommended line size: 100 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
286 2.1 241 3.6 207 5.0 179 6.4 154 7.9 131 9.3 110 10.7
454 3.0 410 5.1 376 7.1 347 9.2 322 11.2 299 13.3 278 15.3
678 4.3 634 7.1 600 10.0 571 12.8 546 15.7 523 18.6 502 21.4
2200
2000
1083 11.2 1049 15.7 1010 20.2 995 24.7 972 29.2 951 33.7
860 26.5 839 30.6
2400 1084 31.8 1063 36.7
1015 6.1 971 10.2 937 14.3 908 18.3 883 22.4
847 5.2 802 8.6 768 12.1 740 15.6 714 19.1 692 22.5 671 26.0
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
90
258
483
932
819
1044
651
12.1
17.3
24.3
38.2
34.7
41.6
29.5
PBHP
13.6
19.4
27.1
38.8
33.0
15.0
21.4
30.0
36.4
72
240
464
801
633
54
223
447
615
1127 6.7
1239 7.3 1195 12.2 1161 17.1 1132 22.0 1107 26.9
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1400
1700
RPM
MODEL 610
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 150 mm; Standard recommended line size: 125 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
382 2.6 323 4.5 277 6.4 239 8.3 205 10.3 175 12.2 147 14.1
607 3.7 547 6.5 502 9.2 464 11.9 430 14.7 400 17.4 371 20.1
906 5.2 847 9.0 802 12.9 764 16.7 730 20.5 699 24.3 671 28.2
2200
2000
1447 14.2 1402 20.2 1363 26.2 1329 32.2 1299 38.2
1149 34.8 1121 40.2
2400
1356 7.5 1297 12.9 1252 18.4 1213 23.8 1180 29.3
1131 6.3 1072 11.0 1027 15.6 988 20.3 955 24.9 924 29.5 896 34.2
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
120
345
645
870
16.0
22.8
32.0
38.8
17.9
25.6
35.8
19.8
28.3
39.6
96
321
621
73
298
597
1506 8.2
1656 9.0 1597 15.5 1551 22.1 1513 28.6 1479 35.2
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1400
1700
RPM
MODEL EB615HP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 125 mm; Standard recommended line size: 150 mmNB; Air Cooled versions only; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
601 3.7 515 6.6 450 9.6 395 12.5 346 15.5 302 18.4
946 5.3 861 9.5 796 13.7 740 17.9 692 22.1 648 26.3
1407 7.4 1322 13.3 1257 19.2 1201 25.0 1153 30.9 1109 36.8
2200
2000
2244 20.9 2179 30.1 2123 39.4
2400
2099 10.6 2014 19.0 1948 27.4 1893 35.8
1753 9.0 1668 16.1 1602 23.3 1547 30.4 1498 37.5
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
PBHP
2329 11.7
2560 12.7 2474 22.8 2409 32.9
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
1000
1400
1700
RPM
MODEL 615
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 175 mm; Standard recommended line size: 150 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
585 3.6 502 6.5 438 9.4 384 12.2 337 15.1 294 17.9 255 20.8
921 5.2 838 9.3 775 13.4 721 17.4 673 21.5 631 25.6 591 29.7
1370 7.3 1287 13.0 1223 18.7 1169 24.4 1122 30.1 1079 35.9 1040 41.6
2200
2000
2184 20.4 2121 29.4 2067 38.4
2400
2043 10.4 1960 18.5 1896 26.7 1843 34.9
1707 8.8 1624 15.8 1560 22.7 1506 29.7 1459 36.6
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
218
555
23.7
33.8
2267 11.4
2492 12.4 2409 22.3 2345 32.1
PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC 10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1100
1300
RPM
MODEL 78
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 130 mm; Standard recommended line size: 125mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
522 3.0 472 5.4 434 7.7 402 10.1 373 12.4 348 14.7 324 17.1
706 3.9 656 6.9 618 9.9 585 12.9 557 15.9 531 19.0 508 22.0
889 4.8 839 8.5 801 12.1 769 15.8 741 19.5 715 23.2 691 26.8
1800
1500
1482 13.8 1444 19.9 1412 25.9 1383 31.9 1357 37.9 1334 43.9
1082 31.6 1058 36.6
2000 1541 42.1 1517 48.8
1256 6.5 1207 11.5 1168 16.5 1136 21.6 1108 26.6
1073 5.6 1023 10.0 985 14.3 953 18.7 924 23.0 898 27.4 875 31.7
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
302
486
669
1312
1036
1495
853
19.4
25.0
30.5
49.9
41.6
55.5
36.1
21.8
28.0
34.2
56.0
46.6
62.2
40.4
24.1
31.0
37.9
62.0
51.6
44.8
282
465
649
1291
1016
1475
832
262
446
629
1272
996
813
1532 7.8
1715 8.7 1666 15.4 1627 22.1 1595 28.7 1567 35.4
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1100
1300
RPM
MODEL 79
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 140 mm; Standard recommended line size: 125 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
580 3.3 525 5.9 482 8.5 447 11.1 415 13.7 386 16.3 360 18.9
784 4.2 729 7.6 686 10.9 650 14.3 619 17.6 590 21. 0 564 24.3
988 5.2 933 9.3 890 13.4 854 17.4 823 21.5 794 25.6 768 29.7
1800
1500
1647 15.2 1604 21.9 1568 28.5 1537 35.2 1508 41.9 1482 48.6
1202 34.9 1176 40.5
2000 1712 46.6 1686 54.0
1396 7.1 1341 12.6 1298 18.2 1262 23.8 1231 29.4
1192 6.1 1137 11.0 1094 15.8 1058 20.6 1027 25.4 998 30.3 972 35.1
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
336
540
744
1458
1152
948
21.5
27.6
33.8
55.3
46.1
39.9
24.1
31.0
37.9
51.6
44.8
26.7
34.3
42.0
49.6
313
517
721
1129
925
291
495
699
903
1702 8.5
1851 16.9 1808 24.3 1772 31.7 1741 39.1
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1100
1300
RPM
MODEL 711
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 160 mm; Standard recommended line size: 150 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
745 4.0 674 7.4 619 10.7 573 14.0 533 17.4 496 20.7 462 24.1
1006 5.2 935 9.5 881 13.8 835 18.1 794 22.4 758 26.6 724 30.9
1268 6.3 1197 11.6 1143 16.8 1097 22.1 1056 27.3 1019 32.6 986 37.8
1800
1500
2113 19.0 2059 27.5 2013 36.1 1972 44.7 1936 53.3 1902 61.9
1543 44.4 1509 51.6
2000 2197 59.2
1792 8.7 1721 15.8 1666 23.0 1620 30.1 1580 37.3
1530 7.5 1459 13.7 1404 19.9 1358 26.1 1318 32.3 1281 38.5 1248 44.7
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
431
693
954
1478
1216
27.4
35.2
43.1
58.7
50.9
PBHP
30.7
39.5
48.3
57.1
34.1
43.8
53.5
401
663
925
1187
374
635
897
2184 10.4
2446 11.5 2375 21.1 2320 30.6 2274 40.1 2234 49.7
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1100
1300
RPM
MODEL 713
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 160 mm; Standard recommended line size: 150 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
848 4.5 767 8.3 705 12.1 653 15.9 607 19.7 565 23.5 526 27.3
1146 5.8 1065 10.7 1003 15.6 951 20.4 905 25.3 863 30.2 825 35.1
1444 7.1 1363 13.0 1301 19.0 1249 25.0 1203 31.0 1161 36.9 1123 42.9
1800
1500
2407 21.3 2345 31.1 2292 40.9 2246 50.7 2205 60.4
1757 50.4 1719 58.5
2000
2041 9.6 1960 17.8 1898 25.9 1845 34.1 1799 42.2
1742 8.4 1662 15.4 1599 22.5 1547 29.5 1501 36.6 1459 43.7 1421 50.7
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
491
789
1087
1385
31.1
40.0
48.9
57.8
34.9
44.9
54.9
38.7
49.8
60.8
457
755
1054
426
724
1022
2488 11.6
2786 12.9 2705 23.7 2643 34.6 2591 45.4 2544 56.3
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1100
1300
RPM
MODEL 715
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
986 5.5 892 9.9 820 14.3 759 18.7 705 23.2 657 27.6 612 32.0
1333 7.0 1239 12.7 1167 18.4 1106 24.1 1052 29.8 1004 35.5 959 41.1
1680 8.6 1586 15.5 1513 22.5 1453 29.4 1399 36.4 1350 43.3 1306 50.3
1800
1500
2799 25.4 2727 36.8 2666 48.2 2613 59.5
2044 59.1
2000
2373 11.7 2279 21.2 2207 30.7 2146 40.1 2092 49.6
2027 10.2 1932 18.4 1860 26.6 1799 34.8 1746 43.0 1697 51.2 1653 59.4
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
571
918
1264
36.4
46.8
57.2
40.8
52.5
532
879
2893 14.1
3240 15.6 3146 28.3 3074 40.9 3013 53.5
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1100
1300
RPM
MODEL LB17
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
1110 6.0 1004 11.0 923 16.0 854 21.0 794 25.9 739 30.9 689 35.9
1500 7.7 1394 14.1 1313 20.5 1245 26.9 1184 33.3 1130 39.7 1079 46.1
1891 9.5 1785 17.3 1703 25.1 1635 32.9 1574 40.7 1520 48.6 1470 56.4
1800
1500
3151 28.3 3069 41.1 3001 53.9
2000
2671 12.9 2565 23.6 2484 34.2 2415 44.9 2355 55.6
2281 11.2 2175 20.4 2094 29.7 2025 38.9 1965 48.1 1910 57.4
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
642
1033
40.9
52.5
3257 15.5
3647 17.2 3541 31.4 3460 45.6 3391 59.9
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL 812
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 150 mm; Standard recommended line size: 150 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
962 6.9 899 10.9 851 15.0 810 19.0 775 23.1 742 27.1 712 31.2
1280 8.8 1217 14.0 1169 19.2 1129 24.5 1093 29.7 1060 34.9 1031 40.1
1439 9.8 1376 15.6 1328 21.4 1288 27.2 1252 33.0 1219 38.8 1190 44.6
1600
1400
2331 24.9 2283 34.2 2242 43.5 2206 52.8 2174 62.0 2144 71.3
1856 54.3 1826 62.4
1800 2492 69.7 2462 80.2
2076 13.7 2013 21.8 1965 29.9 1924 38.1 1888 46.2
1757 11.8 1695 18.7 1646 25.7 1606 32.6 1570 39.6 1538 46.5 1508 53.5
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
685
1003
1162
2117
1798
1480
35.3
45.3
50.4
80.6
70.5
60.4
39.3
50.5
56.2
78.6
67.4
43.4
55.8
61.9
74.3
659
977
1136
1772
1454
634
952
1111
1430
2394 15.7
2712 17.6 2649 28.1 2601 38.5 2560 48.9 2525 59.3
PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1100
1300
RPM
MODEL 710
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 140 mm; Standard recommended line size: 125mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
653 3.6 590 6.6 543 9.5 502 12.4 467 15.3 435 18.3 405 21.2
882 4.7 820 8.4 772 12.2 732 15.9 696 19.7 664 23.5 635 27.2
1112 5.7 1049 10.3 1002 14.9 961 19.5 926 24.1 894 28.7 864 33.3
1800
1500
1852 16.8 1805 24.4 1764 31.9 1729 39.4 1697 46.9 1667 54.5
1353 39.1 1323 45.4
2000 1926 52.1 1897 60.5
1571 7.8 1508 14.0 1460 20.3 1420 26.6 1385 32.8
1341 6.7 1279 12.2 1231 17.6 1191 23.0 1155 28.5 1123 33.9 1094 39.3
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
378
607
837
1640
1296
1066
24.1
31.0
37.9
62.0
51.6
44.8
PBHP
27.0
34.8
42.5
57.9
50.2
30.0
38.5
47.1
55.6
352
581
811
1270
1040
328
557
786
1016
1915 9.3
2082 18.7 2034 27.1 1994 35.4 1958 43.8
57.21107
62.01435
1662 61.41906 9.4
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC 10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL 814
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
1122 7.5 1049 12.3 993 17.0 945 21.7 904 26.5 866 31.2 831 35.9
1494 9.7 1420 15.8 1364 21.9 1317 27.9 1275 34.0 1237 40.1 1202 46.2
1679 10.8 1606 17.5 1550 24.3 1502 31.0 1460 37.8 1423 44.6 1388 51.3
1600
1400
2720 28.0 2663 38.9 2616 49.7 2574 60.5 2536 71.3 2502 82.1
2165 62.4 2130 71.9
1800 2908 80.2
2422 15.1 2348 24.5 2292 34.0 2245 43.5 2203 52.9
2050 12.9 1977 21.0 1921 29.1 1873 37.3 1832 45.4 1794 53.5 1759 61.6
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
799
1170
1356
2098
1727
40.7
52.3
58.1
81.3
69.7
45.4
58.4
64.8
77.8
50.1
64.4
71.6
768
1140
1325
1696
740
1111
1297
2793 17.2
3164 19.4 3091 31.5 3034 43.7 2987 55.9 2945 68.0
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL 816
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
1283 8.2 1199 13.6 1135 19.0 1080 24.4 1033 29.8 990 35.3 950 40.7
1707 10.6 1623 17.5 1559 24.5 1505 31.4 1457 38.4 1414 45.3 1374 52.3
1919 11.7 1835 19.5 1771 27.2 1717 34.9 1669 42.6 1626 50.4 1586 58.1
1600
1400
3108 31.1 3044 43.5 2990 55.9 2942 68.2 2899 80.6
2474 70.5 2435 81.3
1800
2768 16.4 2684 27.2 2619 38.1 2565 48.9 2518 59.7
2343 14.1 2260 23.3 2195 32.6 2141 41.9 2093 51.2 2050 60.4 2010 69.7
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
913
1337
1549
1974
46.1
59.2
65.8
79.0
51.5
66.2
73.5
56.9
73.1
81.3
878
1302
1515
845
1270
1482
3192 18.8
3616 21.1 3532 35.0 3468 48.9 3414 62.8 3366 76.7
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL 818
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
1449 8.9 1355 15.0 1282 21.1 1221 27.2 1167 33.4 1118 39.5 1073 45.6
1928 11.5 1834 19.3 1761 27.2 1700 35.0 1646 42.9 1597 50.7 1552 58.6
2168 12.7 2073 21.5 2001 30.2 1940 38.9 1886 47.6 1837 56.4 1792 65.1
1600
1400
3511 34.3 3439 48.3 3378 62.3 3324 76.2
2796 78.9
1800
3127 17.8 3032 30.0 2960 42.3 2898 54.5 2844 66.7
2647 15.3 2533 25.8 2480 36.2 2419 46.7 2365 57.2 2316 67.7 2271 78.1
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
1031
1511
1750
51.7
66.5
73.8
57.8
74.3
82.6
63.9
82.2
992
1472
1711
955
1434
3606 20.4
4085 22.9 3991 38.6 3918 54.3 3857 70.1 3803 85.8
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL 820
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
1603 9.6 1499 16.3 1418 23.1 1351 29.8 1291 36.6 1237 43.4 1187 50.1
2134 12.3 2029 21.0 1949 29.7 1881 38.4 1821 47.1 1767 55.8 1718 64.4
2399 13.7 2294 23.3 2214 33.0 2146 42.6 2086 52.3 2032 61.9 1983 71.6
1600
1400
3885 37.3 3805 52.8 3737 68.2
1800
3459 19.1 3355 32.6 3274 46.2 3207 59.7 3147 73.2
2929 16.4 2824 28.0 2744 39.6 2676 51.2 2617 62.7 2563 74.3
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
1141
1671
1937
56.9
73.1
81.3
63.6
81.8
1098
1628
3990 21.9
4520 24.6 4415 42.0 4335 59.4 4267 76.7
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL 1012
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 205mm; Standard recommended line size: 200 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
1644 10.4 1537 17.4 1455 24.3 1385 31.2 1324 38.2 1269 45.1 1218 52.0
2188 13.4 2081 22.3 1999 31.2 1929 40.2 1868 49.1 1813 58.0 1762 66.9
2460 14.9 2353 24.8 2771 34.7 2201 44.6 2140 54.5 2084 64.4 2034 74.3
1600
1400
3985 39.7 3902 55.5 3833 71.4 3772 87.2 3716 103.1 3665 118.9
3172 90.2 3121 104.1
1800 4260 116.0 4209 133.8
3548 20.9 3441 34.7 3358 48.6 3289 62.5 3228 76.3
3004 17.9 2897 29.8 2814 41.7 2745 53.5 2684 65.4 2628 77.3 2578 89.2
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
1170
1714
1986
3618
3074
4162
2530
59.0
75.8
84.2
134.8
117.9
151.6
101.1
65.9
84.7
94.2
150.6
131.8
169.5
113.0
72.8
93.7
104.1
166.5
145.7
187.3
124.9
1126
1670
1942
3574
3030
4117
2486
1084
1628
1900
3531
2988
4075
2444
4092 23.8
4636 26.8 4529 44.7 4446 62.5 4377 80.3 4315 98.2
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL 1014
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 230 mm; Standard recommended line size: 250 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
1932 11.6 1806 19.8 1709 27.9 1628 36.1 1556 44.2 1491 52.4 1431 60.5
2571 15.0 2445 25.5 2348 35.9 2267 46.4 2195 56.9 2130 67.4 2070 77.8
2891 16.6 2765 28.3 2668 39.9 2586 51.6 2514 63.2 2449 74.8 2389 86.5
1600
1400
4682 45.2 4585 63.9 4503 82.5 4432 101.1 4367 119.7 4307 138.4
3727 104.8 3668 121.1
1800 5006 134.7 4946 155.7
4169 23.3 4043 39.6 3946 55.9 3864 72.2 3792 88.5
3530 20.0 3404 33.9 3307 47.9 3225 61.9 3153 75.8 3088 89.8 3029 103.8
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
1375
2014
2334
4251
3612
4890
2973
68.7
88.3
98.1
157.0
137.4
176.6
117.7
76.8
98.8
109.8
175.6
153.7
197.6
131.7
85.0
109.3
121.4
194.2
170.0
145.7
1323
1962
2282
4199
3560
4838
2921
1274
1913
2232
4149
3510
2871
4808 26.6
5447 30.0 5321 50.9 5224 71.9 5143 92.8 5071 113.8
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL 1016
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 230 mm; Standard recommended line size: 250 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
2210 12.8 2065 22.1 1955 31.5 1861 40.8 1779 50.1 1705 59.4 1636 68.7
2941 16.5 2796 2686 40.44 2592 52.4 2510 64.4 2436 76.4 2367 88.4
3306 18.3 3162 31.6 3051 44.9 2958 58.2 2875 71.6 2801 84.9 2733 98.2
1600
1400
5354 50.6 5244 71.9 5150 93.2 5068 114.5 4994 135.8 4925 157.1
4263 118.8 4194 137.4
1800 5725 152.8 5656 176.7
4768 25.6 4623 44.3 4513 62.9 4419 81.5 4337 100.2
4037 22.0 3893 37.9 3782 53.9 3689 69.9 3606 85.9 3532 101.8 3464 117.8
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
1573
2304
2669
4862
4131
3400
78.0
100.3
111.5
178.4
156.1
133.8
87.4
112.3
124.8
199.7
174.7
149.8
96.7
124.3
138.1
193.4
165.7
1513
2244
2609
4802
4071
3340
1456
2187
2553
4014
3284
5499 29.3
6230 33.0 6085 56.9 5974 80.9 5881 104.8 5799 128.8
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL 1018
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 250 mm; Standard recommended line size: 250 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
2549 14.2 2382 25.0 2255 35.7 2147 46.5 2052 57.2 1966 68.0 1888 78.7
3392 18.3 3225 32.1 3098 46.0 2990 59.8 2895 73.6 2809 87.4 2731 101.2
3813 20.4 3647 35.7 3519 51.1 3412 66.4 3317 81.8 3231 97.1 3152 112.5
1600
1400
6176 57.1 6048 81.7 5941 106.3 5846 130.8 5760 155.4 5681 180.0
4917 136.0 4838 157.5
1800 6603 174.8
5500 28.5 5333 50.0 5205 71.5 5098 93.0 5003 114.5
4657 24.4 4490 42.9 4362 61.3 4255 79.7 4160 98.1 4074 116.6 3995 135.0
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
1814
2657
3079
4765
3922
89.5
115.1
127.8
179.0
153.4
PBHP
100.2
128.9
143.2
171.8
111.0
142.7
158.5
190.3
1745
2588
3010
3853
1680
2523
2945
3788
6343 32.6
7186 36.6 7019 64.3 6892 91.9 6784 119.6 6689 147.2
PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC 10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
28.5
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL 1020
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 250 mm; Standard recommended line size: 250 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
2826 15.4 2642 27.3 2500 39.3 2381 51.2 2276 63.1 2180 75.0 2093 86.9
3761 19.8 3577 35.1 3435 50.5 3316 65.8 3210 81.1 3115 96.4 3028 111.8
4229 22.0 4044 39.1 3902 56.1 3783 73.1 3678 90.1 3583 107.2 3495 124.2
1600
1400
6849 62.5 6707 89.7 6588 117.0 6482 144.2 6387 171.4 6300 198.7
5452 150.0 5365 173.9
1800 7322 192.9
6098 30.8 5914 54.7 5772 78.5 5653 102.3 5548 126.2
5163 26.4 4979 46.9 4837 67.3 4718 87.7 4613 108.2 4518 128.6 4430 149.0
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
2012
2946
3414
5284
4349
98.8
127.1
141.2
197.7
169.4
110.8
142.4
158.2
189.9
122.7
157.7
175.3
1935
2870
3337
4272
1863
2798
3265
7033 35.2
7968 39.6 7783 70.3 7642 100.9 7522 131.6 7417 162.2
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL 1022
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 310 mm; Standard recommended line size: 300 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
3042 16.3 2844 29.2 2691 42.0 2563 54.8 2449 67.6 2347 80.5 2253 93.3
4048 21.0 3850 37.5 3697 54.0 3569 70.5 3456 87.0 3353 103.5 3259 120.0
4552 23.3 4353 41.7 4200 60.0 4072 78.3 3959 96.6 3856 115.0 3762 133.3
1600
1400
7372 66.6 7219 96.0 7091 125.3 6977 154.6 6875 183.9
5869 160.9 5775 186.6
1800
6564 32.7 6365 58.3 6213 84.0 6084 109.6 5971 135.3
5558 28.0 5359 50.0 5207 72.0 5078 94.0 4965 116.0 4863 137.9 4768 159.9
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
2165
3171
3675
4681
106.1
136.4
151.6
181.9
119.0
152.9
169.9
2083
3089
3592
7570 37.3
8576 42.0 8378 75.0 8225 108.0 8097 140.9 7984 173.9
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL 1024
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 310 mm; Standard recommended line size: 300 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
3320 17.5 3103 31.5 2937 45.5 2796 59.5 2673 73.5 2561 87.5 2458 101.5
4418 22.5 4201 40.5 4035 58.5 3894 76.5 3771 94.5 3659 112.5 3556 130.5
4967 25.0 4750 45.0 4584 65.0 4443 85.0 4320 105.0 4208 125.0 4105 145.0
1600
1400
8044 72.0 7878 104.0 7737 136.0 7614 168.0 7502 200.0
6404 175.0
1800
7163 35.0 6946 63.0 6780 91.0 6639 119.0 6516 147.0
6065 30.0 5848 54.0 5682 78.0 5541 102.0 5418 126.0 5306 150.0 5203 174.0
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
2363
3461
4010
5108
115.5
148.5
165.0
198.0
8261 40.0
9359 45.0 9142 81.0 8976 117.0 8835 153.0 8712 189.0
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL ET7000
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 310 mm; Standard recommended line size: 300 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
3320 17.5 3103 31.5 2937 45.5 2796 59.5 2673 73.5 2561 87.5 2458 101.5
4418 22.5 4201 40.5 4035 58.5 3894 76.5 3771 94.5 3659 112.5 3556 130.5
4967 25.0 4750 45.0 4584 65.0 4443 85.0 4320 105.0 4208 125.0 4105 145.0
1600
1400
8044 72.0 7878 104.0 7737 136.0 7614 168.0 7502 200.0 7399 232.0
6404 175.0 6301 203.0
1800 8600 225.0 8497 261.0
7163 35.0 6946 63.0 6780 91.0 6639 119.0 6516 147.0
6065 30.0 5848 54.0 5682 78.0 5541 102.0 5418 126.0 5306 150.0 5203 174.0
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
2363
3461
4010
7304
6206
5108
115.5
148.5
165.0
264.0
231.0
198.0
129.5
166.5
185.0
259.0
222.0
143.5
184.5
205.0
246.0
2273
3371
3920
6116
5018
2188
3286
3835
4933
8261 40.0
9359 45.0 9142 81.0 8976 117.0 8835 153.0 8712 189.0
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
700
900
1000
1200
RPM
MODEL ET9000
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 350 mm; Standard recommended line size: 350 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Vertical Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.Red Values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
4419 22.1 4131 40.8 3909 59.4 3723 78.0 3558 96.7 3409 115.3 3273 133.9
5881 28.5 5593 52.4 5371 76.4 5184 100.3 5020 124.3 4871 148.3 4734 172.2
6612 31.6 6323 58.2 6102 84.9 5915 111.5 5751 138.1 5602 164.7 5465 191.4
1600
1400
10709 93.2 10487 135.8 10301 178.4 10136 221.0 9987 263.6
8526 230.6 8389 267.9
1800
9536 44.3 9247 81.5 9025 118.8 8839 156.1 8674 193.4
8074 37.9 7785 69.9 7564 101.8 7377 133.8 7213 165.7 7064 197.7 6927 229.6
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
3145
4607
5338
6800
152.6
196.2
218.0
261.6
171.2
220.1
244.6
189.9
244.1
271.2
3026
4488
5219
2913
4375
5105
10997 50.6
12459 56.9 12170 104.8 11949 152.8 11762 200.7 11598 248.6
PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
590
630
670
710
RPM
MODEL ERRG350
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 350 mm; Standard recommended line size: 350 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Right Angle Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.
11088 58 10758 102 10518 146 10338 190 10176 235 10032 279 9888 323
11892 62 11562 109 11322 156 11142 204 10980 251 10836 298 10692 345
12696 66 12366 115 12126 166 11946 216 11784 267 11640 316 11496 366
730 12840 345 12696 39813896 70 13566 125 13326 180 13146 235 12984 290
13494 70 13164 122 12924 176 12744 229 12582 283 12438 335 12294 389
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
9768
10572
11376
12576
12174
367
393
417
453
443
412
440
468
510
496
457
487
517
563
548
9648
10452
11256
12456
12054
9558
10362
11166
12366
11964
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
590
630
670
710
RPM
MODEL ERRG400
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 400 mm; Standard recommended line size: 400 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Right Angle Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.
13926 70 13566 126 13278 181 13026 237 12804 292 12594 349 12426 404
14934 75 14574 134 14286 193 14034 253 13812 312 13602 371 13434 432
15942 79 15582 142 15294 205 15042 270 14820 333 14610 396 14442 459
730 16122 430 15954 49917454 86 17088 154 16806 224 16548 294 16332 361
16950 85 16590 152 16302 219 16050 286 15828 351 15618 418 15450 485
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
12276
13284
14292
15798
15300
460
491
522
569
553
488
520
554
602
586
12186
13194
14202
15714
15210
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
590
630
670
710
RPM
MODEL ERRG445
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 450 mm; Standard recommended line size: 450 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Right Angle Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.
15696 78 15246 142 14934 204 14646 267 14406 329 14196 392 13986 455
16830 83 16380 152 16068 217 15780 286 15540 351 15330 418 15120 485
17964 89 17514 161 17202 231 16914 303 16674 373 16464 445 16254 516
730 18162 485 17952 56219668 97 19212 174 18900 252 18612 330 18378 406
19104 94 18654 170 18342 245 18054 321 17814 396 17604 472 17394 546
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
13782
14916
16050
17760
17190
518
553
587
640
622
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC 10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWC9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
10000 mmWc9000 mmWC8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
Everest is proud to introduce its new range of EZR series PD Blowers. EZR series blowers are large size, high pressure, rotary blowers which have been developed on our rich manufacturing experience to cater to the demand for large capacity & high pressure rotary blowers. It has a special rotor profile which results in a high efficiency & energy saving machine.
FEATURES: Rotor with truss head involute profile, advanced and reasonable, with high efficiency.
Main parts are machined by machining centres and NC facilities, resulting in complete interchangeability, high accuracy & reliable product.
Forced lubrication for gears and bearings. The oil pump is driven by the blower shaft, so no need for extra power. Also, we can use separate electrical power to drive the oil pump.
All models work in direct drive mode.
Available seals: Labyrinth seal, piston ring seal &air extracting seal.
Delivery medium: Air, semi water, gas.
Newly designed oil tank structure with effective heat emission. Cooling water is required only if operating pressures exceed 5000 mmWC, thereby reducing operating expenses.
Split structure design for casing & end plates, resulting in convenience during inspection.Main parts are formed by precision resin sand casting.
Straight Gear instead of traditional skew gear to avoid excess shaft force which would affect bearing life.
Performance Range:
Pressure Rise from 1,000 mmWC to 10,000 mmWC3 3Capacity from 317.9 m /min to 1292 m /min
Application Areas include Food, Mining, Cement, Pneumatic Conveying, Petrochemical, Smelting, Environmental, Electric Power.
EZR SERIES LARGE SIZE HIGH PRESSURE
PD BLOWERS
Everest Blowers are
available as
package units,
ready to install
or as bare blower
units for replacement
MODEL
EZR SERIES PERFORMANCE TABLE
ΔP3Q (m /min)
EZR7 - 500A 1,000 - 10,000 mmWC 317.9~378.1
1,000 - 9,000 mmWC 379.2 ~ 530.4EZR7 - 580B
1,000 - 9,000 mmWC 411.5 ~584.3EZR7 - 600A
1,000 - 8,000 mmWC 465.7~661.2EZR7 - 700A
1,000 - 6,000 mmWC 555.3 ~740.7EZR7 - 750A
1,000 - 5,000 mmWC 637.7 ~841.6EZR7 - 800A
1,000 - 8,000 mmWC 663.1 ~897.0EZR7 - 700B
1,000 - 6,000 mmWC 804.7 ~1,058.2EZR7 - 800B
1,000 - 5,000 mmWC 997 ~1,292EZR7 - 900B
Please contact Everest for further details.
PERFORMANCE TABLE TWIN-LOBE ROTARY BLOWERS
9000 mmWC8000 mmWC7000 mmWC6500 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
590
630
670
710
RPM
MODEL ERRG500
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 500 mm; Standard recommended line size: 500 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Right Angle Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.
21684 105 21144 190 20742 276 20394 362 20064 448 19782 534 19644 578
23244 111 22704 203 22302 295 21954 386 21624 479 21342 570 21204 616
24804 118 24264 216 23862 314 23514 410 23184 508 22902 606 22764 654
730 25242 660 25104 70927144 129 26604 235 26202 339 25854 447 25524 553
26364 125 25824 228 25422 333 25074 436 24744 539 24462 642 24324 708
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
9000 mmWC8000 mmWC7500 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
Q3m /hr
PBHP
A I R C O O L E D WAT E R C O O L E D
SPEED
590
630
670
710
RPM
MODEL ERRG450
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 450 mm; Standard recommended line size: 450 mmNB; Air Cooled & Water Cooled versions available; Standard Orientation: Right Angle Flow; Max. Vacuum: 5000 mmWCSuitable for Air / Gas Duty & Pressure / Vacuum Applications.
17556 86 17106 156 16794 226 16506 295 16266 363 16056 433 15846 503
18816 91 18366 166 18054 240 17766 314 17526 389 17316 463 17106 536
20076 98 19626 177 19314 255 19026 334 18786 413 18576 492 18366 571
730 20466 536 20256 62221972 106 21516 192 21204 278 20916 363 20682 449
21342 103 20892 186 20580 271 20292 354 20052 439 19842 522 19632 605
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
15744
17004
18264
20160
19530
538
574
610
665
648
Water Cooled Package Blowersfor High Pressure Applications
Blower For Mechanical Vapor Re-compression
SCOPE OF SUPPLY (TWIN LOBE & TRILOBE BLOWERS):
A) Bare Blower:
1. Blower; 2. Suction & Discharge ICP/Companion Flanges; 3. Blower Pulley
B) Blower With Standard Accessories (Pressure Duty) Including Water Cooled Blowers:
1. Blower; 2. Common Motor & Blower Base Frame with Motor Rails & Belt Tightening Arrangement; 3. Belt Guard / Coupling Guard; 4. Suction Air Filter; 5. Suction Silencer; 6. Pressure Gauge; 7. Safety Relief Valve (Spring Loaded Type); 8. Pulleys & Vee Belts / Coupling; 9. Foundation Bolts; 10. Interconnecting Pipe with Companion Flange; 11. O&M Manual
C) Blower with Standard Accessories (Vacuum Duty):
1. Blower; 2. Common Motor & Blower Base Frame with Motor Rails & Belt Tightening Arrangement ; 3. Belt Guard / Coupling Guard; 4. Discharge Silencer; 5. Vacuum Gauge ; 6. Vacuum Relief Valve (Spring Loaded Type); 7. Pulleys & Vee Belts / Coupling; 8. Foundation Bolts; 9. Interconnecting Pipe with Companion Flange; 10. O&M Manual
D) Blower with Standard Accessories (Gas Duty):
1. Blower; 2. Common Motor & Blower Base Frame with Motor Rails & Belt Tightening Arrangement; 3. Belt Guard / Coupling Guard; 4. Pr./Vac. Gauge; 5. Pulleys & Vee Belts / Coupling; 6. Foundation Bolts; 7. Interconnecting Pipe with Companion Flanges; 8. O&M Manual
SINGLE STAGE HIGH SPEED CENTRIFUGAL BLOWERS (TURBO BLOWERS)
Everest is proud to introduce its new range of Single Stage High Speed Centrifugal Blowers (Turbo Blowers).
FEATURES Large capacity and continuous flow because of big size sectional area and high rotary speed.
Compact structure, smaller size than Piston Compressor and Roots Blower of same capacity.
Long time stable running and less maintenance.
No pollution on the compressed Gas.
Wide range of Impeller material: Forged Aluminum, Forged Steel or Stainless Steel.
Gear Box Design with Helical Type Nitrogen-hardening gears with more than 20 years life.
Designed on tri-variate movement theory resulting in high efficiency of 82%.
Wide Performance Range: With axial inlet guide vanes, flow capacity range can be adjusted from 45% to110% of the
designed value.
High Pressure Ratio, Max 3.0.
GD2 is low, easier to start.
Easily to control the Noise. High grade balanced and light style rotor will generate high frequency noise which can
be easily eliminated.
Covers less floor space.
Reliable operation.
Standard Unit consists of High Speed Single Stage Centrifugal Blower, Gear Box,
Control Cabinet, Inlet GuideV anes & Thin Oil Station.
Performance Range:3 3Flow Capacity: 60 m /min to 1,000 m /min
2 2Outlet Pressure: 1.5 kgf/cm ~ 2.8 kgf/cm
Application Areas include Waste Water Treatment,
FGD Oxidation Air Blower & MVR.
Please contact Everest for further details.
Multistage Centrifugal Blowers (Casting Type) are based on design & principle of welded multistage low speed centrifugal
blowers. These new generation high efficiency products are the latest product offering from Everest Group.
FEATURES Shell of inlet & outlet and return channel of the blower are fully adapt to impeller resulting in streamlined design &
hence reduced losses.
Impeller is designed by three-dimensional meridian plane and compound curve technology, resulting in high
efficiency.
Impeller intake seal-inducer improves inlet fluidity of the impeller.
Airfoil return flow blade reduces losses resulting in higher static pressures.
Blower performance is optimized with fluid analysis technology. Polytropic efficiency is upto 78%.
Some models use three dimensional impeller, resulting in higher efficiency & good performance.
Rotors are dynamically balanced, resulting in low vibration, high reliability & low overall noise.
Advanced & reasonable blower structure with no easy-worn parts and convenient installation, operation &
maintenance.
Standard Unit consists of Blower, coupling, protective cover and anchor bolts. Special accessories (Filter, Silencer, etc.) are
prepared according to specific process requirements.
Performance Range:3 3Flow Capacity: 20 m /min to 800 m /min
2 2Outlet Pressure: 0.2 kgf/cm ~ 1 kgf/cm
Application Areas include Water Treatment, Waste Water
Treatment, Biogas Recovery, Vacuum Cleaning, Air Knife
Drying, Flotation & Mineral Beneficiation, Galvanization
Process & Electroplating, Fluid & Piscina Oxygenation, Process
Gas Conveying, Paper Making & Printing, & Air Firing
(Desulphurization, Carbon Black, Blast Furnace Process etc.).
Please contact Everest for further details.
MULTISTAGE CENTRIFUGAL BLOWERS
Everest Blowers are
available as
package units,
ready to install
or as bare blower
units for replacement
ETL 300 EVEREST | AIR COOLED
Tri-Lobe Rotary Air
Blowers have been
designed keeping
the specific demands
of the industry of
continuous duty
operation,
sturdy design,
reduced noise,
reduced
pulsations and
vibrations,
longer bearing
life and minimal
maintenance in
mind
VEREST, leading manufacturer of Roots Blowers in India, introduces the all Enew Tri-Lobe Roots Blowers. Tri-lobe technology means blowers have lobe tips exposed to 120 degrees around the rotor instead of 180 degrees as in a bi-
lobe blower. This provides a stiffer rotor set, meaning less deflection at any load. These blowers have been designed keeping the specific demands of the industry of continuous duty operation, sturdy design, reduced noise, reduced pulsations and vibrations, longer bearing life and minimal maintenance in mind. Everest Blowers are produced on the latest state-of-art CNC machines from Haas (USA), Mazak (Japan ) and HMT (India), thereby ensuring a quality product. These blowers are designed for continuous duty service. Complete package units are shipped with all essential accessories and electric motor, ready to install, on plug and play concept. Everest Tri-Lobe blowers are supplied with built-in safety & monitoring equipment such as safety relief valve and Pressure/V acuum gauge.
WORKING PRINCIPLE
Everest Tri-Lobe Rotary Compressors/Blowers are positive displacement units, whose pumping capacity is determined by size, operating speed and pressure conditions. It employs two Tri-Lobe impellers mounted on parallel shafts, rotating in opposite direction within a casing closed at the ends by side plates. As the impellers rotate, air is drawn into one side of the casing and forced out of the opposite side against the existing pressures. The differential pressure developed, therefore, depends upon the resistance of the connected system. The Blowers, being positive displacement type, do not develop pressure within the casing but the discharge pressure depends upon the system resistance/back pressure. Effective sealing of the compressor inlet area from the discharge area is accomplished by use of very small operational clearance, eliminating the need of any internal lubrication of the lobes. A pair of accurately machined alloy steel, hardened and ground timing gears maintain clearances between the impellers, during rotation. The air, thus delivered, is 100% OIL FREE. The pumping capacity of a lobe compressor, operating at constant speed remains relatively independent of inlet and discharge pressure variations. These Blowers are constant volume machines, which deliver a fixed discharge against the system back pressure. It is, therefore, essential to ensure that minimum pipeline restrictions, at the inlet and discharge, are imposed. Adequate size piping and large radius bends ensure minimum line losses resulting in higher efficiency and low power
TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS
TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS
ACOUSTIC HOODS | ENCLOSURES
EVEREST PRESSURE & VACUUM SYSTEMS
Leading the way for INNOVATIVE SOLUTIONS
Engineering | Evaluation | Designing | Manufacturing | Testing | Execution | Post Sales & Service
FEATURES
TRI-LOBE ROTARY AIR BLOWERS
These Blowers are
constant volume
machines, which
deliver a fixed
discharge against
the system back
pressure
• Anti-friction bearings
• Tri Lobe Rotor design, suitable for both Pressure Duty andV acuum Duty
• 100% oil free air delivery
• Fail safe labyrinth sealing
• Extended shaft design for cool running
• Rigid one piece CI casing & end plates
• Standard Orientation: Right Angle Flow
• Large inlet & outlet connections for minimal loss
• Alloy steel toughened shafts ground to close tolerances
• Factory engineered, Factory guaranteed, superior product
• Alloy steel hardened and ground timing gears, oil splash lubricated
• Improved volumetric efficiency and reduced operating temperatures
• Dynamically balanced rotor shaft assembly (Grade 6.3 ISO 1940-1986)
• Performance testing as per standard test procedure STP-01 based on BS 1571-2:1975 and ISO 1217:2009
• Tri-Lobe construction having low pulsations and low noise
• All blowers are manufactured on state of the art, imported CNC machines, machined to close tolerances with
high degree of accuracy on profile machining, ensuring high volumetric efficiency
• All major components are interchangeable making Everest the first and only manufacturer to attain the same
• Non-contact type labyrinth seals, with vent, offers lifelong sealing
• Right angle flow orientation with suction top, resulting in smaller foot print
consumption. Sudden change in pipeline cross section should also be avoided. To change capacity, it is necessary either to change speed (energy saving) or vent some of the air into atmosphere (not energy saving). The air must not be re-circulated from the discharge to suction as it may result in overheating. No attempt should ever be made to control the capacity of compressor by means of throttle valves in the intake or discharge piping. This increases the power load on the motor and may seriously damage the compressor. There is an increase in the discharge air temperature due to heat of compression. As a thumb rule the discharge air temperature increases @
0 2 10 C for every 0.1 Kg/cm of P above the inlet temperature.
POSITION-1 POSITION-2 POSITION-3 POSITION-4
PACKAGE BLOWER SYSTEMS
PERFORMANCE TABLE TRI-LOBE ROTARY BLOWERS
8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
Q3m /hr
PBHP
A I R C O O L E D
SPEED
1500
2000
2400
2700
RPM
MODEL ETL40
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 40 mm; Standard recommended line size: 40 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red Values for BHP indicate suitable for Intermittent Duty Applications only.
3300
3000
3600
Q3m /hr
PBHP
31 0.3 25 0.5 21 0.6 17 0.8 14 1.0 11 1.1
46 0.4 40 0.6 36 0.9 32 1.1 29 1.3 26 1.5
58 0.5 52 0.8 48 1.0 44 1.3 41 1.5 38 1.8
67 0.6 61 0.9 56 1.1 53 1.4 50 1.7 47 2.0
75 0.6 70 1.0 65 1.3 62 1.6 58 1.9 56 2.3
84 0.7 79 1.0 74 1.4 71 1.8 67 2.1 64 2.5
93 0.8 88 1.1 83 1.5 80 1.9 76 2.3 73 2.7
8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
Q3m /hr
PBHP
A I R C O O L E D
SPEED
800
1200
1500
1800
RPM
MODEL ETL50
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 50 mm; Standard recommended line size: 50 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Blue cells for FAD indicate next higher standard line size recommended.
2500
2200
2800
Q3m /hr
PBHP
67 0.9 53 1.2 41 1.6 32 2.0 24 2.3 16 2.7 10 3.1 3 3.5
118 1.3 104 1.8 92 2.4 83 2.9 75 3.5 67 4.1 61 4.6 54 5.2
156 1.6 142 2.3 131 3.0 121 3.7 113 4.4 106 5.1 99 5.8 92 6.5
195 1.9 180 2.8 169 3.6 160 4.4 151 5.3 144 6.1 137 6.9 131 7.8
246 2.3 231 3.4 220 4.4 211 5.4 202 6.4 195 7.4 188 8.5 182 9.5
284 2.7 269 3.8 258 5.0 249 6.1 241 7.3 233 8.5 226 9.6 220 10.8
322 3.0 308 4.3 296 5.6 287 6.9 279 8.2 271 9.5 265 10.8 258 12.1
Q3m /hr
PBHP
A I R C O O L E D
SPEED
800
1200
1500
1800
RPM
MODEL ETL65
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 65 mm; Standard recommended line size: 65 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red values for BHP indicate suitable for Intermittent Duty Applications only; Blue cells for FAD indicate next higher standard line size recommended.
2500
2200
2800
Q3m /hr
PBHP
116 1.0 100 1.6 87 2.2 77 2.7 67 3.3 59 3.9 51 4.4 44 5.0
193 1.6 177 2.4 165 3.3 154 4.1 145 5.0 136 5.8 129 6.6 121 7.5
251 2.0 235 3.0 223 4.1 212 5.1 203 6.2 195 7.3 187 8.3 180 9.4
310 2.4 293 3.6 281 4.9 270 6.2 261 7.4 253 8.7 245 10.0 238 11.2
387 2.9 371 4.4 358 6.0 348 7.5 339 9.1 330 10.6 322 12.2 315 13.7
445 3.3 429 5.0 416 6.8 406 8.6 397 10.3 388 12.1 381 13.9 373 15.6
487 5.6 475 7.6 464 9.6 455 11.6 446 13.5 439 15.5
Q3m /hr
PBHP
A I R C O O L E D
SPEED
800
1200
1500
1800
RPM
MODEL ETL80
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 80 mm; Standard recommended line size: 80 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red values for BHP indicate suitable for Intermittent Duty Applications only; Blue cells for FAD indicate next higher standard line size recommended.
2400
2100
2700
Q3m /hr
PBHP
209 1.8 179 2.9 155 3.9 136 4.9 118 6.0 102 7.0 88 8.0 74 9.0
351 2.7 320 4.3 297 5.8 277 7.4 260 8.9 244 10.5 229 12.0 216 13.6
457 3.4 426 5.4 403 7.3 383 9.2 366 11.2 350 13.1 336 15.0 322 17.0
563 4.1 533 6.4 509 8.8 489 11.1 472 13.4 456 15.7 442 18.0 428 20.4
669 4.8 639 7.5 615 10.2 596 12.9 578 15.6 562 18.3 548 21.0 534 23.8
745 8.6 721 11.7 702 14.8 684 17.9 669 21.0 654 24.1 641 27.1
760 27.1 747 30.5
8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
Q3m /hr
PBHP
A I R C O O L E D
SPEED
800
1200
1500
1800
RPM
MODEL ETL100
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 100 mm; Standard recommended line size: 100 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red values for BHP indicate suitable for Intermittent Duty Applications only; Blue cells for FAD indicate next higher standard line size recommended.
2500
2200
2800
Q3m /hr
PBHP
306 2.2 270 3.7 242 5.1 218 6.5 197 8.0 179 9.4 161 10.9 145 12.3
503 3.4 467 5.5 439 7.7 415 9.8 394 12.0 376 14.1 358 16.3 342 18.4
651 4.2 615 6.9 587 9.6 563 12.3 542 15.0 524 17.7 506 20.4 490 23.0
799 5.0 763 8.3 735 11.5 711 14.7 690 18.0 671 21.2 654 24.4 638 27.7
996 6.1 960 10.1 932 14.0 908 18.0 887 21.9 869 25.9 851 29.8
1144 7.0 1108 11.5 1080 16.0 1056 20.5 1035 24.9 1016 29.4
1292 7.8 1256 12.9 1228 17.9 1204 22.9 1183 27.9 1164 33.0
Q3m /hr
PBHP
A I R C O O L E D
SPEED
800
1000
1200
1400
RPM
MODEL ETL125
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 125 mm; Standard recommended line size: 125 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Blue cells for FAD indicate next higher standard line size recommended.
1800
1600
2000
Q3m /hr
PBHP
640 3.8 589 6.6 550 9.3 517 12.1 488 14.9 462 17.7 438 20.5 416 23.2
831 4.7 780 8.2 741 11.7 708 15.1 679 18.6 653 22.1 629 25.6 606 29.0
1022 5.7 971 9.8 932 14.0 899 18.2 870 22.3 844 26.5 820 30.7 797 34.8
1212 6.6 1161 11.5 1122 16.3 1090 21.2 1061 26.1 1034 30.9 1010 35.8 988 40.7
1403 7.6 1352 13.1 1313 18.7 1280 24.2 1251 29.8 1225 35.3 1201 40.9 1179 46.5
1594 8.5 1543 14.8 1504 21.0 1471 27.3 1442 33.5 1416 39.8 1392 46.0 1369 52.3
1784 9.4 1734 16.4 1695 23.3 1662 30.3 1633 37.2 1606 44.2 1582 51.1 1560 58.1
Q3m /hr
PBHP
A I R C O O L E D
SPEED
800
1000
1200
1400
RPM
MODEL ETL150
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 150 mm; Standard recommended line size: 150 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red values for BHP indicate suitable for Intermittent Duty Applications only; Blue cells for FAD indicate next higher standard line size recommended.
1800
1600
2000
Q3m /hr
PBHP
863 4.6 813 8.2 775 11.7 743 15.3 715 18.9 689 22.5 665 26.1 643 29.6
1109 5.7 1059 10.2 1021 14.7 989 19.2 960 23.6 935 28.1 911 32.6 889 37.1
1355 6.9 1305 12.2 1267 17.6 1235 23.0 1206 28.4 1181 33.7 1157 39.1 1135 44.5
1600 8.0 1551 14.3 1512 20.6 1480 26.8 1452 33.1 1426 39.4 1403 45.6 1381 51.9
1846 9.2 1796 16.3 1758 23.5 1726 30.6 1698 37.8 1672 45.0 1649 52.1 1627 59.3
2092 10.3 2042 18.4 2004 26.4 1972 34.5 1944 42.5 1918 50.6 1894 58.7 1872 66.7
2338 11.5 2288 20.4 2250 29.4 2218 38.3 2189 47.3 2164 56.2 2140 65.2 2118 74.1
Q3m /hr
PBHP
A I R C O O L E D
SPEED
800
900
1000
1200
RPM
MODEL ETL200
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 200 mm; Standard recommended line size: 200 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.
1600
1400
1800
Q3m /hr
PBHP
1403 8.7 1309 14.7 1236 20.6 1175 26.6 1121 32.5 1072 38.5 1027 44.4 986 50.3
1607 9.8 1513 16.5 1440 23.2 1379 29.9 1325 36.6 1276 43.3 1231 50.0 1189 56.6
1811 10.9 1717 18.4 1644 25.8 1583 33.2 1529 40.6 1480 48.1 1435 55.5 1393 62.9
2219 13.1 2124 22.0 2052 30.9 1991 39.9 1937 48.8 1888 57.7 1843 66.6 1801 75.5
2627 15.3 2532 25.7 2460 36.1 2399 46.5 2345 56.9 2296 67.3 2251 77.7 2209 88.1
3035 17.5 2940 29.4 2868 41.3 2807 53.1 2753 65.0 2704 76.9 2659 88.8 2617 100.7
3443 19.7 3348 33.0 3276 46.4 3214 59.8 3161 73.2 3112 86.5 3067 99.9 3025 113.3
PERFORMANCE TABLE TRI-LOBE ROTARY BLOWERS
8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
ETL100 Everest | Air Cooled
EVEREST PRESSURE & VACUUM SYSTEMS
Leading the way for INNOVATIVE SOLUTIONS TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS
TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS
ACOUSTIC HOODS | ENCLOSURES
STANDARD ACCESSORIESCommon Motor & Blower Base Frame with Motor Rails and Belt tightening arrangement, Belt Guard/Coupling Guard, Suction Air Filter, Suction Silencer, Pressure Gauge, Pressure Relief Valve (Spring Loaded), Pulleys & Belts/Coupling, Foundation Bolts, Interconnecting Line with Flanges, Non-Return Valve, Operation & Maintenance Manual. Discharge Silencer for Model ETL 100 and above. Electric Motor forms a part of Standard Accessories for Package Blower Systems only.
SALIENT FEATURES
• All Blowers are manufactured on state-of-the-art, imported CNC machines to close tolerances and high degree of accuracy on profile machining, ensuring high volumetric efficiency
• All major components are interchangeable
• Blowers are energy efficient
• Trilobe construction having low pulsations & low noise
• Blowers have all bearings and gears oil splash lubricated. Additionally they have non contact Labyrinth Seals with vent. Therefore these blowers are suitable for high speed and high pressure
• Right-angle flow orientation with suction top, resulting in smaller foot print
ETL300 Everest | Air Cooled
PERFORMANCE TABLE TRI-LOBE ROTARY BLOWERS
Q3m /hr
PBHP
A I R C O O L E D
SPEED
800
900
1000
1200
RPM
MODEL ETL250
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 250 mm; Standard recommended line size: 250 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red values for BHP indicate suitable for Intermittent Duty Applications only;
1600
1400
1800
Q3m /hr
PBHP
2199 11.9 2076 21.0 1981 30.1 1902 39.2 1831 48.3 1768 57.4 1709 66.5 1655 75.5
2511 13.4 2388 23.6 2293 33.8 2214 44.1 2143 54.3 2080 64.5 2022 74.8 1967 85.0
2823 14.9 2700 26.2 2605 37.6 2526 49.0 2455 60.3 2392 71.7 2334 83.1 2279 94.4
3447 17.8 3324 31.5 3230 45.1 3150 58.8 3080 72.4 3016 86.0 2958 99.7 2903 113.3
4071 20.8 3948 36.7 3854 52.6 3774 68.6 3704 84.5 3640 100.4 3582 116.3 3528 132.2
4696 23.8 4572 42.0 4478 60.2 4398 78.3 4328 96.5 4264 114.7 4206 132.9 4152 151.1
5320 26.8 5196 47.2 5102 67.7 5022 88.1 4952 108.6 4889 129.1 4830 149.5 4776 170.0
Q3m /hr
PBHP
A I R C O O L E D
SPEED
800
900
1000
1200
RPM
MODEL ETL300
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 300 mm; Standard recommended line size: 300 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.Red values for BHP indicate suitable for Intermittent Duty Applications only. Blue cells for FAD indicate next higher standard line size recommended.
1600
1400
1800
Q3m /hr
PBHP
4911 24 4276 44 4583 63 4464 83 4358 102 4263 122 4175 141 4093 161
5580 27 5395 49 5253 71 5133 93 5028 115 4933 137 4845 159 4763 181
6250 30 6065 55 5923 79 5803 104 5698 128 5602 152 5515 177 5433 201
7589 36 7404 66 7262 95 7142 124 7037 154 6942 183 6854 212 6772 241
8929 43 8744 77 8602 111 8482 145 8376 179 8281 213 8193 247
10268 49 10083 88 9941 127 9821 166 9716 205 9620 244
11607 55 11422 99 11280 143 11161 186 11055 230 10960 274
Q3m /hr
PBHP
A I R C O O L E D
SPEED
650
730
800
880
RPM
MODEL E3HF350
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Q3m /hr
PBHP
Blower Opening: 350 mm; Standard recommended line size: 350 mmNB; Right Angle Flow Configuration.Suitable for Air Duty, Pressure / Vacuum Applications; Max. Vacuum: 5000 mmWC; Air Cooled versions only.
980
Q3m /hr
PBHP
8958 47 8658 83 8418 120 8208 157 8022 193 7860 230
10170 54 9870 93 9630 136 9420 176 9234 217 9072 258
11220 58 10920 105 10680 148 10470 192 10284 237 10122 282
12438 63 12138 114 11898 162 11688 212 11502 262 11340 310
13944 70 13644 126 13404 181 13194 235 13008 290 12846 345
8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
8000 mmWC7000 mmWC5000 mmWC4000 mmWC3000 mmWC 6000 mmWC2000 mmWC1000 mmWC
Quieter Operation: The Tri-Lobe rotor enables smooth air output, with less pulsations. This results in a significant reduction of emitted sound.
Longer Life: The smooth power cycles means less “impacting load” and results in longer bearing and unit life.
A convenient sight glass makes it easy to check oil levels. Drain valve is mounted in the front of the unit, hence easily accessible.
Direct coupled drive resulting in increased drive efficiency, reduced noise and longer service life.
Built-in monitoring and safety equipment such as pressure gauge and safety relief valve.
Anti-vibration pads absorb vibrations before they reach the floor.
Easily mountable suction air filter with non woven polyester media for surface and depth filtration. Mean pore size 25 microns.
ETL 025 EVEREST | AIR COOLED
Tri-Lobe technology
means blowers have
lobe tips
exposed to 120
degrees around
the rotor,
instead of 180
degrees as in a
bi-lobe blower
VEREST, leading manufacturer of Roots Blowers in India, introduces the all Enew Vertical Tri-Lobe Roots Blowers. These blowers have been designed keeping the specific demands of the industry of compact & sturdy machine,
reduced noise, minimal space requirements, least vibrations, longer bearing life & minimal maintenance, in mind. Everest blowers are produced on latest state-of-art CNC machines from USA & Japan ensuring quality product.
Complete package units are shipped with all essential accessories & electric motor, ready to install on plug & play concept. These blowers are designed for continuous duty service & require minimal maintenance. EverestV ertical Tri-Lobe Blowers come with built-in safety and monitoring equipment such as safety relief valve & pressure gauge.
Tri-Lobe technology means blowers have lobe tips exposed to 120 degrees around the rotor, instead of 180 degrees as in a bi-lobe blower. This provides a stiffer rotor set, meaning less deflection at any load. These blowers provide 100% Oil Free Air & are extensively used in Sewage Treatment Plants, Effluent Treatment Plants, Aquaculture, Chemical Plants and Electroplating Plants.
TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS
TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS
ACOUSTIC HOODS | ENCLOSURES
EVEREST PRESSURE & VACUUM SYSTEMS
Leading the way for INNOVATIVE SOLUTIONS
Engineering | Evaluation | Designing | Manufacturing | Testing | Execution | Post Sales & Service
FEATURES
SPECIFICATIONS
TRI-LOBE VERTICAL ROTARY AIR BLOWERS
Everest Tri-Lobe
Vertical Rotary Air
Blowers are
produced on latest
state-of-art CNC
machines from
USA & Japan
ensuring quality
product
LONGERL I F E
• Noise level < 80dB(A) (subject to load conditions)
• Unit Weight: 48 Kg (with 1.5 HP/2 Pole Electric Motor)
• Variable Frequency Drive can be supplied for speed/capacity regulation
• Standard Orientation: Horizontal Flow
• Blower Opening : 1” BSP
• Recommended Line Size : 25 mmNB
MODEL SPEED 1000 mmWg 2000 mmWg 3000 mmWg 4000 mmWg 5000 mmWg3 3 3 3 3 1.5 HP Motor rpm m /hr BHP m /hr BHP m /hr BHP m /hr BHP m /hr BHP
ETL 25 EB Package 2850 26 0.4 23 0.5 20 0.7 18 0.8 16 0.9
PERFORMANCE TABLE | TRI-LOBE VERTICAL ROTARY AIR BLOWERSPRESSURE DUTY APPLICATION
Capacities are at inlet condition| Tolerance: Capacity ±10% and Power +5%3 2Conversions: 1 M /Hr~0.588 CFM~16.67 LPM |1000 mmWG~1.42 PSI~0.1 Kg/cm
PACKAGE BLOWER SYSTEMS
EVEREST PACKAGE BLOWER
Reduction of
mechanical noise is
beyond the scope of
silencers. Everest
acoustic
enclosures are
one of the most
effective means
for containment
of excessive
noise
VEREST, leading manufacturer of Roots Blowers introduces acoustic Eenclosures for blowers. Everest acoustic enclosures are one of the most effective means for containment of excessive noise and for the insulation of
the workers from the noise. Even where silencers are used, they can only treat the air borne noise. The treatment of the mechanical noise from the blower, motor, etc. is beyond the scope of silencers. Thus, in order to achieve low noise levels, that are often statutory requirements, Noise Enclosures / Acoustic Hoods are required.
Everest sound reduction enclosures have been designed for effective noise reduction of blowers placed inside. Everest's economical design provides noise reduction of 12-25 dB(A) bringing down the total noise emitted to safe acceptable limits.
TWIN-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE ROTARY AIR BLOWERS | COMPRESSORS
TRI-LOBE VERTICAL ROTARY AIR BLOWERS | COMPRESSORS
TWIN LOBE ROTARY GAS BLOWERS | COMPRESSORS
ACOUSTIC HOODS | ENCLOSURES
EVEREST PRESSURE & VACUUM SYSTEMS
Leading the way for INNOVATIVE SOLUTIONS
Engineering | Evaluation | Designing | Manufacturing | Testing | Execution | Post Sales & Service
FEATURES
SPECIFICATIONS
ACOUSTIC HOODS | ENCLOSURES
Everest's economical
design provides
noise reduction
of 12 - 25 dB(A)
• Noise Control Noise level reduction to the tune of 25-30% is achieved
• Mobility The enclosures can be easily shifted or transported
• Ease of Maintenance Adequate space is available inside the canopy for easy maintenance
• Elimination of Civil Work Enclosures are suitable for open installation and hence require no separate building or
shed.
• Design The sound reduction enclosures are specially designed to reduce noise pollution to suit the local
environment. These are engineered to take care of air intake & outlet, resulting in a pleasing & attractive design.
• Construction The robust body work of sound reduction enclosures is due to its construction from preformed
heavy gauge sheet steel section and its reinforcement with fabricated superstructure. Rubber gaskets are provided
to all doors and external joints to resist weathering. The bolted superstructure provides easy removal of panels for
maintenance or servicing of blowers.
• Air Circulation Sufficient cooling air inlet acoustic louvers and exhaust fans are provided in the enclosure for
efficient air circulation avoiding derating of the machine.
• Installation The sound reduction enclosures are preassembled on a support frame and can be easily & quickly
assembled at site.
PACKAGE BLOWER SYSTEMS
EVEREST PRESSURE & VACUUM SYSTEMS
Leading the way for INNOVATIVE SOLUTIONS
BEARINGS
VEE BELTSGEARS
SILENCERS & FILTERS
SEALS
ROTOR SET
GREASE GEAR OIL NON RETURN VALVE
FEATURES
• Readily available
• Fast delivery
• Guaranteed fit and function
• Service kits for routine product
maintenance
SPARESBearings, Oil Seals, Gears, Rotors, Spacer Bushes, Blower lubricant, Gaskets, Piston Rings.
ACCESSORIESSafety Relief Valves, Filters, Suction Silencers, Discharge Silencers, Pulleys, Vee Belts, Hubs, Drive couplings, Pressure Gauge, Vacuum Gauge, Non ReturnV alves.
THE EVEREST ADVANTAGE Retain your advantage with factory genuine replacement parts & accessories. All parts meet original manufacturing specifications and tolerances for guaranteed fit and function. Pre-packaged overall kits with detailed service manuals are available on request.
Due to constant improvements, technical specifications are subject to change without notice. For further clarifications, contact our technical team who shall be glad to assist you to overcome application related problems.
RELIEF VALVE PRESSURE GAUGE
EverestSpares and Accessories