Date: March 16, 2010 Test results certify that Rubber Bark™ meets the ASTM standard for Lead and Phthalates as set by the CPSIA for children’s product safety. St. Louis Testing Laboratory 2810 Clark Avenue St. Louis, MO 63103-2574 Test Lab: See reverse side for actual test results. A copy of the complete report is available upon request.
Citation preview
Test Lab: St. Louis Testing Laboratory 2810 Clark Avenue St. Louis, MO 63103-2574
Date: March 16, 2010
See reverse side for actual test results. A copy of the complete report is available upon request.
Phthalate Analysis and Lead Content Test Results
Test results certify that Rubber Bark™ meets the ASTM standard for Lead and Phthalates as set by the CPSIA for children’s product safety.
Ag Link, Inc. - Rubber Bark™ - 13000 Newport Road, Ballico, CA 95303 - 209-634-8849www.rubberbark.com - www.agmat.com
Rubber Bark™ Test Results for Phthalates and Lead Content
Substance SU-01 Method Detection Limit
DEHP (Di-(2-ethylexyl) phthalate) ND 0.05%DBP (Dibutyl phthalate) ND 0.05%BBP (Benzyl butyl phthalate) ND 0.05%DINP (Diisononyl phthalate) ND 0.05%DIDP (Diisodecyl phthalate) ND 0.05%DnOP (di-n-octyl phthalate) ND 0.05%Total Lead ND 80ppm
Units: Phthalates - Percent by Weight (%) Lead - Parts per Million (ppm)ND: Not Detected above Method Detection Limit
Conclusion:The phthalate analysis and lead content of the tested product is in compliance with the requirements of the CPSIA, Section 108 & Section 101 standard.
Rubber Bark™ Test Results for Lead Content and Soluble Heavy Metals
Funded in part by a grant from CalRecycle
Substance SU-04Sealer
SU-BKBlack
SU-BL Blue
SU-BRBrown
Maximum Allowable Limit
Method Detection Limit
Total Lead <80 <80 <80 <80 90 80Soluble Antimony <50 <50 <50 <50 60 50Soluble Arsenic <15 <15 <15 <15 25 15Soluble Barium <900 <900 <900 <900 1000 900Soluble Cadmium <65 <65 <65 <65 75 65Soluble Chromium <50 <50 <50 <50 60 50Soluble Lead <80 <80 <80 <80 90 80Soluble Mercury <50 <50 <50 <50 60 50Soluble Selenium <400 <400 <400 <400 500 400
Substance SU-CYCypress
SU-GRGreen
SU-GYGray
SU-RDRed
Maximum Allowable Limit
Method Detection Limit
Total Lead <80 <80 <80 <80 90 80Soluble Antimony <50 <50 <50 <50 60 50Soluble Arsenic <15 <15 <15 <15 25 15Soluble Barium <900 <900 <900 <900 1000 900Soluble Cadmium <65 <65 <65 <65 75 65Soluble Chromium <50 <50 <50 <50 60 50Soluble Lead <80 <80 <80 <80 90 80Soluble Mercury <50 <50 <50 <50 60 50Soluble Selenium <400 <400 <400 <400 500 400
Units: Parts per Million (ppm)
Conclusion:The lead and soluble heavy metals content of the tested products are in compliance with the requirements of the CPSIA, Section 101, 16 CFR 1303 standard.
Ag Link, Inc. - Rubber Bark™ - 13000 Newport Road, Ballico, CA 95303 - 209-634-8849www.rubberbark.com - www.agmat.com