9
LASK-MA -Leak Detection -Sensor Broken Detection -Sensitive

LASK-MA - AUTO SENSOR KOREAautosensorkorea.co.kr/download/catalog/Leak_Sensor(LASK... · 2020-03-23 · -Leak Detection-Sensor Broken Detection-Sensitive. LASK-MA Model LASK-MA Current

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LASK-MA - AUTO SENSOR KOREAautosensorkorea.co.kr/download/catalog/Leak_Sensor(LASK... · 2020-03-23 · -Leak Detection-Sensor Broken Detection-Sensitive. LASK-MA Model LASK-MA Current

LASK-MA-Leak Detection

-Sensor Broken Detection

-Sensitive

Page 2: LASK-MA - AUTO SENSOR KOREAautosensorkorea.co.kr/download/catalog/Leak_Sensor(LASK... · 2020-03-23 · -Leak Detection-Sensor Broken Detection-Sensitive. LASK-MA Model LASK-MA Current

LASK-MA

Model

LASK-MA

Current Consumption

80mA max.

Size(WxHxD)

88x58x27

EXTERNAL DIMENSIONS

Weight

60g

Target Liquid

Water, acidic, alkali, etc

Input Power Source

DC 24V

Below 5W

Operating Temperature Range

-5 ~ 40℃

Temperature Range

-20 ~ 75℃

LASK-MA

LV

SN

58.3

* The above specifications can be changed by the manufacturer without notice to improve the reliability of the product.

Page 3: LASK-MA - AUTO SENSOR KOREAautosensorkorea.co.kr/download/catalog/Leak_Sensor(LASK... · 2020-03-23 · -Leak Detection-Sensor Broken Detection-Sensitive. LASK-MA Model LASK-MA Current

TAPE TYPE 센서 : LASK-MCB-SERIES

본 제품은 필름 타입의 센서로써 물과 화학물질 판별이 가능하며 실버+카본

블랙 재질로 제작하여 가볍고 부식에 강합니다.

LEAK 발생 후 닦아서 재사용이 가능한 제품입니다.

MCB SENSOR

MODEL LASK-MCB-18-I

SIZE 17 x 0.2(±0.5)

MATERIAL SUS304, POLYACETAL..

SETUP LENGTH 1M ~10M(LASK-MA_1EA 기준)

1

2

① 누액 검출 부분(화학용 필름 센서 상단부)

② 부착 부분(화학용 필름 센서 하단부)

③ Start 커넥터

④ 리드 케이블

Page 4: LASK-MA - AUTO SENSOR KOREAautosensorkorea.co.kr/download/catalog/Leak_Sensor(LASK... · 2020-03-23 · -Leak Detection-Sensor Broken Detection-Sensitive. LASK-MA Model LASK-MA Current

포인트 센서 : LASK-P-S

본 제품은 물과 액상 화학물질을 구별하여 화학물질에만 반응하여 감지되는

특수 포인트 센서로써 세계 최초의 기술로 개발되었으며 기존 포인트 센서의

문제점 (잦은 오작동, 약한 내구성, 물에도 경보 작동 등)을 동시에 해결 할

수 있도록 제작.

POINT SENSOR

MODEL LASK-P-S

SIZE 74.2 * 28.7

MATERIAL SUS316, POLYACETAL..

Page 5: LASK-MA - AUTO SENSOR KOREAautosensorkorea.co.kr/download/catalog/Leak_Sensor(LASK... · 2020-03-23 · -Leak Detection-Sensor Broken Detection-Sensitive. LASK-MA Model LASK-MA Current

제품 특징

• LASK-P-S 포인트센서는 물과 액상 화학물질을 구별하여 화학물질에만

반응하여 감지되는 특수 포인트 센서로써 세계 최초의 기술로 발되었으며

기존 포인트 센서의 문제점 (잦은 오작동, 약한 내구성, 물에도 경보 작동

등)을 동시에 해결한 특허 제품입니다.

• LASK-MA 컨트롤러는 포인트 센서 전용으로 개발 되었으며 알람 Modbus

통신 연결로 원거리 중앙 감시반(실내)에서 상태 확인도 가능하며 알루미늄

재질로 제작되어 외부 충격과 노이즈에 강하여 실외 설치에 최적화 되어

있으며 다양한 환경과 열악한 조건에서도 설치 및 적용이 용이 합니다.

제품 장점

Page 6: LASK-MA - AUTO SENSOR KOREAautosensorkorea.co.kr/download/catalog/Leak_Sensor(LASK... · 2020-03-23 · -Leak Detection-Sensor Broken Detection-Sensitive. LASK-MA Model LASK-MA Current

기존 제품 비교

SEN SEN

SEN

신제품

실외 설치 시 빗물과 화학물질 구별 불가능

SEN

지면으로부터 올라오는 노이즈에 취약하며

센서 자체가 갖고 있는 높은 저항으로 인해

잦은 가성 알람이 발생.

탱크 주변 세척수로 인한 가성 알람 발생

실외 설치 시 빗물과 화학물질 구별 가능

지면으로부터의 전원 노이즈의 영향을

거의 받지 않음

세척수로 인한 알람 오류가 없음

Page 7: LASK-MA - AUTO SENSOR KOREAautosensorkorea.co.kr/download/catalog/Leak_Sensor(LASK... · 2020-03-23 · -Leak Detection-Sensor Broken Detection-Sensitive. LASK-MA Model LASK-MA Current

시공 분야

제조 · 생산 산업

재배 산업 발전소

중공업

적용분야

건설업

파이프 라인 및배관 연결 부분

기계 장비 주변 탱크 주변생산 설비

하수처리장

그 외 화학 물질 사용하는 분야 어디든 사용 가능

Page 8: LASK-MA - AUTO SENSOR KOREAautosensorkorea.co.kr/download/catalog/Leak_Sensor(LASK... · 2020-03-23 · -Leak Detection-Sensor Broken Detection-Sensitive. LASK-MA Model LASK-MA Current

Product features

1) It is optimized for various installation environments and can be installed both indoors

and outdoors.

2) Around the building where chemical solutions are stored

3) Around the tank where chemical solutions are stored

4) Lower section of chemical transport piping

5) Places where other chemicals may leak

6) It can be detected with small amount of leakage and operates real-time alarms

7) Water the sensor as soon as possible after detecting any leakage.

8) When identifying water and chemicals, only chemicals can be identifie

d and alarm is activated.

How to Install a Product

1) When this product is shipped from the factory, the initial settings of the LV

and SN are completed and shipped.

Do not change the setting value during installation.2) Install the device in a place where there is no electrical contact, such as a metal surface,

at the installation site.

3) Install a cable so that it does not come into contact with chemicals in case of leakage.

4) When installing the sensor, install the sensor so that the lower part faces the floor.5) Connect the cable after installing the sensor and module.(The power cable is the last.

Connect and put all power in.)

6) Contact the company in case of failure or damage.

* The above specifications can be changed by the manufacturer without notice to improve the reliability of the product.

Situation and how to take action in case of leakage

1) The Leak LED on the controller will illuminate red

and the buzzer will operate simultaneously.

2) Locate the leak and remove the chemical clean and clean the sensor with water.

Clean, dry, and press the reset button on the controller.

(The risk of electric shock Please be careful.)

3) If the buzzer sounds after pressing the Reset button, please wash the sensor again.

Page 9: LASK-MA - AUTO SENSOR KOREAautosensorkorea.co.kr/download/catalog/Leak_Sensor(LASK... · 2020-03-23 · -Leak Detection-Sensor Broken Detection-Sensitive. LASK-MA Model LASK-MA Current

Head Office:

Samsungtechnopark 703, 97, Jungbu-daero 448beon-gil, Yeongtong-gu, Suwon-si, Gyeonggi-do, Republic of Korea

TEL: 031-278-6292 FAX: 031-278-6293

Website : www.autosensorkorea.co.kr

Installation and Warning

1) Please refer to the instructions for safety and product damage.

2) Regular inspection is required at least once every one to three months. (Be

sure to check the integrity of the sensor, controller, lead cable, etc.)

3) Do not install and use this product in an explosive environment as it

is not a safe width structure.

4) If the sensor is exposed to water for a long period of time (at least 24 hours), th

e sensor may become small, so keep it as dry as possible.

5) Specifications of this product may be changed to improve performance.

6) Do not change the factory setting.

(The product is not responsible for failure or damage caused by th

e change in setting values.)

7) In the event of a nearby electromagnetic wave, there is a risk of malfunction.

8) There is a risk of static electricity generation and discharge, so be careful when touching.

9) Check the power voltage (DC24V) before turning on the power supply a

nd connect it at the end.

10) In the event of an inspection or failure, contact the company and proceed.

11) Install the machine in a location where there is no electrical contact, s

uch as a metal surface, at the installation site.

12) Ensure that the installation is as far away as possible where leakage detection is required.

13) It is normal for an open circuit alarm to sound when the sensor is not connected.

If this is the case If the alarm does not sound, contact the company in defect condition

14) This product is not installed outdoors directly, and cables to ALARM (NO, NC, COM) and

SENSOR are used as less than 30M and do not have cables directly connected to the outside.

15) SMPS and Filter must be used when using this product.