LAPORAN

PROGRAM UJI BANDING (PROFICIENCY TEST) ANTAR LABORATORIUM

SKEMA KHUSUS SEMESTER I-2016

Bahan Uji:

AIR PERMUKAAN VI BATCH 1 (APDS VI-1)

Ref. No. 003/UR/BMD/2016

PARAMETER UJI:

Nitrat (NO3-), Sulfat (SO4

2-), dan Klorida (Cl

-)

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Page 2: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page i of iii

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

Ref. No. 003/UR/BMD/2016

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

KATA PENGANTAR

Puji syukur kiranya kita panjatkan kepada Alloh SWT yang berkenan melimpahkan

karunia-Nya sehingga ‘Program Uji Banding Antar Laboratorium (Proficiency Test) Skema

Khusus Semester I-2016’ untuk bahan uji Air Permukaan VI Batch 1 (APDS VI-1) dengan

parameter uji nitrat (NO3-), sulfat (SO4

2-), dan klorida (Cl

-) telah berhasil dilaksanakan dan

diselesaikan sampai dengan diterbitkannya laporan ini.

Program uji banding antar laboratorium merupakan salah satu instrumen yang sangat

penting sebagai sarana jaminan mutu eksternal (external quality control) bagi laboratorium

pengujian dan kalibrasi sesuai dengan persyaratan standard SNI ISO/IEC 17025:2008. Dengan

mengikuti program uji banding, laboratorium dapat melakukan evaluasi kinerja pengujian yang

dilakukan dalam rangka melakukan peningkatan secara berkesinambungan (continuous

improvement) untuk memberikan layanan terbaik kepada pelanggan.

Program skema khusus kali ini diikuti oleh 7 (tujuh) laboratorium dengan 6 (enam)

diantaranya telah terakreditasi SNI ISO/IEC 17025:2008 oleh Komite Akreditas Nasional (KAN).

Setiap laboratorium peserta diberikan 2 (dua) buah bahan uji yang keduanya harus diukur dan

dilaporkan masing-masing secara independen. Hal ini dimaksudkan supaya diperoleh data yang

memenuhi pola distribusi normal dengan N≥10.

Dalam program uji banding ini masih digunakan nilai konsensus (consensus value) dari

laboratorium peserta dalam melakukan evaluasi, sehingga tidak memuaskan dalam

ketertelusuran (traceability) secara metrologi. Akan tetapi BMD Laboratory meyakini bahwa hal

tersebut tidak mengurangi manfaat dari pelaksanaan program uji banding ini.

BMD Laboratory sebagai provider uji banding antar laboratorium menyampaikan apresiasi

setinggi-tingginya kepada seluruh pihak yang telah membantu dan menyukseskan kegiatan ini.

Khususnya kepada seluruh laboratorium peserta atas partisipasi aktifnya mengikuti program uji

banding APDS VI-1. Ucapan terimakasih juga disampaikan kepada tim ahli yang telah

Page 3: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page ii of iii

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

Ref. No. 003/UR/BMD/2016

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

bekerja keras mengolah data dan menyusun laporan ini. Akhirnya, BMD Laboratory

menyampaikan permohonan maaf sekiranya terdapat kekurangan dalam penyelenggaraan

program uji banding antar laboratorium. Kritik, saran, dan masukan yang membangun sangat

kami harapkan untuk menghadirkan program uji banding yang semakin baik ke depannya.

Semoga laporan ini dapat dimanfaatkan oleh laboratorium peserta dan pihak-pihak terkait.

Tangerang Selatan, 31 Mei 2016

Ir. Renaldo Moontri

CEO BMD Group

(Selaku Manajer Puncak BMD Laboratory)

Page 4: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page iii of iii

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

Ref. No. 003/UR/BMD/2016

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

DAFTAR ISI

KATA PENGANTAR ......................................................................................................................... i

DAFTAR ISI ................................................................................................................................... iii

I. PENDAHULUAN .................................................................................................................... 1

II. PELAKSANAAN ..................................................................................................................... 1

III. STATISTIKA PENGOLAHAN DATA ......................................................................................... 2

III.1 Penilaian Laboratorium ............................................................................................... 2

III.2 Penetapan Nilai Evaluasi Uji Banding .......................................................................... 2

III.3 Penetapan SDPA .......................................................................................................... 2

IV. HASIL UJI BANDING ANTAR LABORATORIUM ...................................................................... 3

IV.1 Parameter Nitrat (NO3-) .............................................................................................. 5

IV.2 Parameter Sulfat (SO42-

) ............................................................................................. 7

IV.3 Parameter Klorida (Cl-) ............................................................................................... 9

V. PENUTUP ........................................................................................................................... 11

VI. REFERENSI .......................................................................................................................... 11

Annex A Rekapitulasi Hasil z-score Program Uji Banding ......................................................... 13

Annex B Rekapitulasi Bias Nilai Peserta Terhadap Nilai Konsensus ......................................... 14

Annex C Evaluasi Distribusi Normal Data Program Uji Banding ............................................... 16

Page 5: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 1 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

I. PENDAHULUAN

Air permukaan berasal dari aliran langsung air hujan, lelehan salju, dan aliran yang berasal

dari air tanah, termasuk air sungai, air rawa, air danau dan air waduk. Kualitas air

permukaan sangat ditentukan oleh parameter kimia, fisika, dan biologi. Beberapa

parameter kimia (khususnya anion) yang terkandung dalam air permukaan alami yang

belum tercemar dapat dilihat pada Tabel 1.

Tabel 1. Parameter Kimia dalam Air Permukaan Alami[1]

No. Parameter Satuan Konsentrasi

1. Nitrat (NO3-) mg/L Maks. 10 mg/L

2. Sulfat (SO42-) mg/L Maks. 1000 mg/L

3. Klorida (Cl-) mg/L Maks. 1000 mg/L

Salah satu jaminan mutu bagi laboratorium pengujian dan kalibrasi sesuai persyaratan

dalam SNI ISO/IEC 17025:2008 adalah partisipasi dalam uji banding antar laboratorium atau

uji profisiensi[2] sebagai jaminan mutu eksternal (external quality control). Untuk itu BMD

Laboratory menyelenggarakan program uji banding antar laboratorium (proficiency test)

untuk bahan uji Air Permukaan VI Batch 1 (APDS VI-1) dengan tujuan sebagai berikut:

1. Sebagai sarana jaminan mutu eksternal (external quality control) bagi laboratorium

peserta khususnya laboratorium yang menerapkan standard SNI ISO/IEC 17025:2008.

2. Membantu laboratorium dalam mengevaluasi unjuk kerja pengujian kadar nitrat (NO3-),

sulfat (SO42-), dan klorida (Cl-) untuk bahan uji air minum dalam kemasan.

II. PELAKSANAAN

Berikut adalah jadual pelaksanaan program uji banding antar laboratorium (proficiency test)

yang diselenggarakan oleh BMD Laboratory untuk bahan uji Air Permukaan VI Batch 1

(APDS VI-1):

Page 6: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 2 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

a. Penutupan pendaftaran: 07 April 2016

b. Pendistribusian bahan uji: 21 April s.d. 04 Mei 2016

c. Pelaporan hasil analisis oleh laboratorium peserta: Maks. 18 Mei 2016

d. Pendistribusian laporan program uji banding oleh BMD Laboratory: Maks. 01 Juni 2016

III. STATISTIKA PENGOLAHAN DATA

III.1 Penilaian Laboratorium

Penilaian terhadap unjuk kerja laboratorium menggunakan z-score dengan tiga kriteria

penilaian sebagai berikut:

� Untuk |z-score|≤2,0 dikategorikan memuaskan diberi lambang ‘OK’

� Untuk 2,0<|z-score|<3,0 dikategorikan meragukan diberi lambang ‘$’

� Untuk |z-score|≥3,0 dikategorikan kurang memuaskan diberi lambang ‘$$’

III.2 Penetapan Nilai Evaluasi Uji Banding

Penetapan nilai evaluasi uji banding menggunakan dua pendekatan statistika yaitu:

� Robust Statistic Algoritma A Mean sesuai ISO 13528:2005(E)[3]. Nilai tersebut

merupakan nilai konsensus dari peserta (consensus value).

� Seleksi data menggunakan perangkat lunak Distribution AnalyzerTM, Taylor

Enterprises, Inc.[4]

III.3 Penetapan SDPA

SDPA (simpangan baku yang digunakan dalam evaluasi) ditetapkan menggunakan tiga

pendekatan statistika yaitu:

� Robust Statistic Algoritma A Mean sesuai ISO 13528:2005(E) atau SD Robust

� Simpangan Baku Horwitz[5] atau SD Horwitz

� SDPA yang ditetapkan (Assigned SDPA)

Page 7: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 3 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

IV. HASIL UJI BANDING ANTAR LABORATORIUM

Sebanyak 7 (tujuh) laboratorium telah berpartisipasi dalam program uji banding antar

laboratorium (proficiency test) yang diselenggarakan oleh BMD Laboratory untuk bahan uji

Air Permukaan VI Batch 1 (APDS VI-1) dengan parameter uji nitrat (NO3-), sulfat (SO4

2-), dan

klorida (Cl-). Keenam laboratorium tersebut merupakan laboratorium terakreditasi SNI

ISO/IEC 17025:2008 oleh Komite Akreditasi Nasional (KAN). Masing-masing laboratorium

diberikan 2 (dua) buah bahan uji dengan kombinasi kode seperti pada Tabel 2.

Tabel 2. Kombinasi Kode Bahan Uji

Rekapitulasi hasil pengujian oleh laboratorium peserta disajikan seperti pada Tabel 3.

Seluruh data hasil uji banding dapat diolah dengan baik menggunakan Robust Statistic

Algoritma A Mean sesuai ISO 13528: 2005(E). Selain itu dilakukan juga evaluasi data

menggunakan perangkat lunak Distribution AnalyzerTM guna memastikan bahwa data yang

diolah mengikuti pola distribusi normal pada tingkat kepercayaan 95%. Nilai evaluasi uji

banding (assigned value) merupakan nilai konsensus (consensus value) dari laboratorium

peserta sehingga nilai tersebut bukan merupakan nilai acuan yang tertelusur secara

metrologi ke sistem satuan internasional (SI).

No. Kode Bahan Uji Status Akreditasi

1. BMD-1501-16B1 BMD-1511-16B1 Ya

2. BMD-1502-16B1 BMD-1512-16B1 Tidak

3. BMD-1503-16B1 BMD-1513-16B1 Ya

4. BMD-1504-16B1 BMD-1514-16B1 Ya

5. BMD-1505-16B1 BMD-1515-16B1 Ya

6. BMD-1506-16B1 BMD-1516-16B1 Ya

7. BMD-1507-16B1 BMD-1517-16B1 Ya

Page 8: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 4 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

Tabel 3. Rekapitulasi Hasil Pengujian Laboratorium Peserta

No. Kode Lab. Nitrat (NO3

-) Sulfat (SO4

2-) Klorida (Cl

-)

mg.L-1

mg.L-1

mg.L-1

1. BMD-1501-16B1 47,76±5,61 79,29±1,89 103,72±6,26

Metoda SNI 6989.74-2009 SNI 6989.20-2009 SNI 6989.19-2009

2. BMD-1502-16B1 69,52 87,92 113,82

Metoda Ion Kromatografi Ion Kromatografi Ion Kromatografi

3. BMD-1503-16B1 26,25±1,94 84,46±6,97 108,60±0,35

Metoda APHA 4500-NO3E-2012 US EPA 375.4-1983 APHA 4500-Cl-B-2012

4. BMD-1504-16B1 52,60±4,60 93,59±9,54 106,33±3,73

Metoda APHA-AWWA 4500B SNI 06-6989.20-2004 SNI 06-6989.19-2004

5. BMD-1505-16B1 102,17 96,90 110,66

Metoda DEPKES

RI.93.351.871.043 SNI 6989.20-2009 SNI 6989.19-2009

6. BMD-1506-16B1 41,82±2,24 80,5±2,45 102,98±1,95

Metoda SNI 06-2480-1991 SNI 6989.20-2009 SNI 6989.19-2009

7. BMD-1507-16B1 39,12 95,33 106,85

Metoda LKD.IK-07

(Spektrofotometer Kit) LKD.IK-10

(Spektrofotometer Kit) LKD.IK-17 (Titrimetri)

8. BMD-1511-16B1 48,19±5,61 80,38±1,89 103,48±7,09

Metoda SNI 6989.74-2009 SNI 6989.20-2009 SNI 6989.19-2009

9. BMD-1512-16B1 69,22 88,10 113,66

Metoda Ion Kromatografi Ion Kromatografi Ion Kromatografi

10. BMD-1513-16B1 26,91±1,95 87,60±6,96 107,10±0,34

Metoda APHA 4500-NO3E-2012 US EPA 375.4-1983 APHA 4500-Cl-B-2012

11. BMD-1514-16B1 52,32±4,58 93,59±9,54 106,24±3,73

Metoda APHA-AWWA 4500B SNI 06-6989.20-2004 SNI 06-6989.19-2004

Page 9: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 5 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

IV.1 Parameter Nitrat (NO3-)

Sebanyak 14 (empat belas) laporan hasil pengujian untuk parameter nitrat (NO3-) diterima

oleh BMD Laboratory dan 8 (delapan) diantaranya disertai dengan laporan nilai estimasi

ketidakpastian diperluas dengan k=2 pada tingkat kepercayaan 95%. Dari hasil pengolahan

data secara statistika diperoleh sebanyak 8 (delapan) data yang dilaporkan laboratorium

masuk dalam kategori ‘memuaskan’ (|z-score|≤2,0), 4 (empat) data yang dilaporkan

laboratorium masuk dalam kategori ‘meragukan’ (2,0<|z-score|<3,0), dan 2 (dua) data yang

dilaporkan laboratorium masuk dalam kategori ‘kurang memuaskan’ (|z-score|≥3,0). Hasil

pengolahan data disajikan pada Tabel 4 dan Gambar 1.

Tabel 4. Hasil Pengolahan Data Parameter Nitrat (NO3-)

No. Kode Peserta Nilai Laporan

Peserta (mg/L)

U, k=2

(mg/L)

Nilai Evaluasi Uji

Banding (mg/L)

SDPA

(mg/L) z-score Kategori

1. BMD-1501-16B1 47.76 5.61 49.13 8.99 -0.15 OK

2. BMD-1502-16B1 69.52 - 49.13 8.99 2.27 $

3. BMD-1503-16B1 26.25 1.94 49.13 8.99 -2.54 $

4. BMD-1504-16B1 52.60 4.60 49.13 8.99 0.39 OK

5. BMD-1505-16B1 102.17 - 49.13 8.99 5.90 $$

6. BMD-1506-16B1 41.82 2.24 49.13 8.99 -0.81 OK

7. BMD-1507-16B1 39.12 - 49.13 8.99 -1.11 OK

No. Kode Lab. Nitrat (NO3

-) Sulfat (SO4

2-) Klorida (Cl

-)

mg.L-1

mg.L-1

mg.L-1

12. BMD-1515-16B1 109,78 97,58 109,42

Metoda DEPKES

RI.93.351.871.043 SNI 6989.20-2009 SNI 6989.19-2009

13. BMD-1516-16B1 41,96±2,24 81,00±2,45 102,98±1,96

Metoda SNI 06-2480-1991 SNI 6989.20-2009 SNI 6989.19-2009

14. BMD-1517-16B1 42,84 94,00 106,35

Metoda LKD.IK-07

(Spektrofotometer Kit) LKD.IK-10

(Spektrofotometer Kit) LKD.IK-17 (Titrimetri)

Page 10: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 6 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

No. Kode Peserta Nilai Laporan

Peserta (mg/L)

U, k=2

(mg/L)

Nilai Evaluasi Uji

Banding (mg/L)

SDPA

(mg/L) z-score Kategori

8. BMD-1511-16B1 48.19 5.61 49.13 8.99 -0.10 OK

9. BMD-1512-16B1 69.22 - 49.13 8.99 2.23 $

10. BMD-1513-16B1 26.91 1.95 49.13 8.99 -2.47 $

11. BMD-1514-16B1 52.32 4.580 49.13 8.99 0.35 OK

12. BMD-1515-16B1 109.78 - 49.13 8.99 6.74 $$

13. BMD-1516-16B1 41.96 2.240 49.13 8.99 -0.80 OK

14. BMD-1517-16B1 42.84 - 49.13 8.99 -0.70 OK

Keterangan:

Nilai evaluasi uji banding merupakan nilai konsensus (consensus value) laboratorium

peserta yang diperoleh dari pengolahan data secara statistika menggunakan Robust

Statistic Algoritma A Mean sesuai ISO 13528:2005(E) dengan sebelumnya dilakukan analisis

menggunakan perangkat lunak Distribution AnalyzerTM (lihat Anex C), sedangkan SDPA

adalah simpangan baku yang ditetapkan (assigned SDPA) dari rata-rata SD Robust dan SD

Horwitz. U yaitu ketidakpastian diperluas dengan faktor cakupan (k)=2 pada tingkat

kepercayaan 95%.

Page 11: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 7 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

10.00

16.00

22.00

28.00

34.00

40.00

46.00

52.00

58.00

64.00

70.00

76.00

82.00

88.00

94.00

100.00

106.00

112.00

BM

D-1

503-

16B

1

BM

D-1

513-

16B

1

BM

D-1

507-

16B

1

BM

D-1

506-

16B

1

BM

D-1

516-

16B

1

BM

D-1

517-

16B

1

BM

D-1

501-

16B

1

BM

D-1

511-

16B

1

BM

D-1

514-

16B

1

BM

D-1

504-

16B

1

BM

D-1

512-

16B

1

BM

D-1

502-

16B

1

BM

D-1

505-

16B

1

BM

D-1

515-

16B

1

NO

3-(m

g/L

)

Lab. Code

Cons. value (X)

X+2SDPA

X+3SDPA

X-2SDPA

X-3SDPA

Cons. value = 49.13 mg/LAlgoritma A Mean ISO 13528:2005(E)SDPA = 8.99 mg/L (Assigned)SD Horwitz = 4.37 mg/LSD Robust = 13.61 mg/L

©BMD Laboratory

Gambar 1. Grafik Hasil Uji Banding Parameter Nitrat (NO3-)

IV.2 Parameter Sulfat (SO42-

)

Sebanyak 14 (empat belas) laporan hasil pengujian untuk parameter nitrat (NO3-) diterima

oleh BMD Laboratory dan 8 (delapan) diantaranya disertai dengan laporan nilai estimasi

ketidakpastian diperluas dengan k=2 pada tingkat kepercayaan 95%. Dari hasil pengolahan

data secara statistika diperoleh sebanyak 14 (empat belas) data yang dilaporkan

laboratorium masuk dalam kategori ‘memuaskan’ (|z-score|≤2,0). Hasil pengolahan data

disajikan pada Tabel 5 dan Gambar 2.

Page 12: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 8 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

Tabel 5. Hasil Pengolahan Data Parameter Sulfat (SO42-)

No. Kode Peserta Nilai Laporan

Peserta (mg/L)

U, k=2

(mg/L)

Nilai Evaluasi Uji

Banding (mg/L)

SDPA

(mg/L) z-score Kategori

1. BMD-1501-16B1 79.29 1.89 88.59 7.22 -1.29 OK

2. BMD-1502-16B1 87.92 - 88.59 7.22 -0.09 OK

3. BMD-1503-16B1 84.46 6.97 88.59 7.22 -0.57 OK

4. BMD-1504-16B1 93.59 9.54 88.59 7.22 0.69 OK

5. BMD-1505-16B1 96.90 - 88.59 7.22 1.15 OK

6. BMD-1506-16B1 80.5 2.45 88.59 7.22 -1.12 OK

7. BMD-1507-16B1 95.33 - 88.59 7.22 0.93 OK

8. BMD-1511-16B1 80.38 1.89 88.59 7.22 -1.14 OK

9. BMD-1512-16B1 88.10 - 88.59 7.22 -0.07 OK

10. BMD-1513-16B1 87.60 6.96 88.59 7.22 -0.14 OK

11. BMD-1514-16B1 93.59 9.540 88.59 7.22 0.69 OK

12. BMD-1515-16B1 97.58 - 88.59 7.22 1.25 OK

13. BMD-1516-16B1 81.00 2.45 88.59 7.22 -1.05 OK

14. BMD-1517-16B1 94.00 - 88.59 7.22 0.75 OK

Keterangan:

Nilai evaluasi uji banding merupakan nilai konsensus (consensus value) laboratorium

peserta yang diperoleh dari pengolahan data secara statistika menggunakan Robust

Statistic Algoritma A Mean sesuai ISO 13528:2005(E) dengan sebelumnya dilakukan analisis

menggunakan perangkat lunak Distribution AnalyzerTM (lihat Anex C). SDPA merupakan

simpangan baku yang diperoleh dari persamaan Horwitz (SD Horwitz). U yaitu

ketidakpastian diperluas dengan faktor cakupan (k)=2 pada tingkat kepercayaan 95%.

Page 13: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 9 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

60.00

64.00

68.00

72.00

76.00

80.00

84.00

88.00

92.00

96.00

100.00

104.00

108.00

112.00

116.00

120.00

124.00

128.00

BM

D-1

501-

16B

1

BM

D-1

511-

16B

1

BM

D-1

506-

16B

1

BM

D-1

516-

16B

1

BM

D-1

503-

16B

1

BM

D-1

513-

16B

1

BM

D-1

502-

16B

1

BM

D-1

512-

16B

1

BM

D-1

504-

16B

1

BM

D-1

514-

16B

1

BM

D-1

517-

16B

1

BM

D-1

507-

16B

1

BM

D-1

505-

16B

1

BM

D-1

515-

16B

1

SO

42

-(m

g/L

)

Lab. Code

Cons. value (X)

X+2SDPA

X+3SDPA

X-2SDPA

X-3SDPA

Cons. value = 88.59 mg/LAlgoritma A Mean ISO 13528:2005(E)SDPA = 7.22 mg/L (SD Horwitz)SD Robust = 7.51 mg/L

©BMD Laboratory

Gambar 2. Grafik Hasil Uji Banding Parameter Sulfat (SO42-)

IV.3 Parameter Klorida (Cl-)

Sebanyak 14 (empat belas) laporan hasil pengujian untuk parameter nitrat (NO3-) diterima

oleh BMD Laboratory dan 8 (delapan) diantaranya disertai dengan laporan nilai estimasi

ketidakpastian diperluas dengan k=2 pada tingkat kepercayaan 95%. Dari hasil pengolahan

data secara statistika diperoleh sebanyak 14 (empat belas) data yang dilaporkan

laboratorium masuk dalam kategori ‘memuaskan’ (|z-score|≤2,0). Hasil pengolahan data

disajikan pada Tabel 6 dan Gambar 3.

Page 14: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 10 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

Tabel 6. Hasil Pengolahan Data Parameter Klorida (Cl-)

No. Kode Peserta Nilai Laporan

Peserta (mg/L)

U, k=2

(mg/L)

Nilai Evaluasi Uji

Banding (mg/L)

SDPA

(mg/L) z-score Kategori

1. BMD-1501-16B1 103.72 6.26 107.18 3.84 -0.90 OK

2. BMD-1502-16B1 113.82 - 107.18 3.84 1.73 OK

3. BMD-1503-16B1 108.60 0.35 107.18 3.84 0.37 OK

4. BMD-1504-16B1 106.33 3.73 107.18 3.84 -0.22 OK

5. BMD-1505-16B1 110.66 - 107.18 3.84 0.91 OK

6. BMD-1506-16B1 102.98 1.95 107.18 3.84 -1.10 OK

7. BMD-1507-16B1 106.85 - 107.18 3.84 -0.09 OK

8. BMD-1511-16B1 103.48 7.09 107.18 3.84 -0.97 OK

9. BMD-1512-16B1 113.66 - 107.18 3.84 1.69 OK

10. BMD-1513-16B1 107.10 0.34 107.18 3.84 -0.02 OK

11. BMD-1514-16B1 106.24 3.730 107.18 3.84 -0.25 OK

12. BMD-1515-16B1 109.42 - 107.18 3.84 0.58 OK

13. BMD-1516-16B1 102.98 1.96 107.18 3.84 -1.10 OK

14. BMD-1517-16B1 106.35 - 107.18 3.84 -0.22 OK

Keterangan:

Nilai evaluasi uji banding merupakan nilai konsensus (consensus value) laboratorium

peserta yang diperoleh dari pengolahan data secara statistika menggunakan Robust

Statistic Algoritma A Mean sesuai ISO 13528:2005(E) dengan sebelumnya dilakukan analisis

menggunakan perangkat lunak Distribution AnalyzerTM (lihat Anex C). SDPA merupakan SD

Robust, yaitu simpangan baku yang diperoleh dari pengolahan data secara statistika

menggunakan Robust Statistic Algoritma A Mean sesuai ISO 13528:2005(E). U yaitu

ketidakpastian diperluas dengan faktor cakupan (k)=2 pada tingkat kepercayaan 95%.

Page 15: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 11 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

90.00

93.00

96.00

99.00

102.00

105.00

108.00

111.00

114.00

117.00

120.00

123.00

126.00

129.00

BM

D-1

516-

16B

1

BM

D-1

506-

16B

1

BM

D-1

511-

16B

1

BM

D-1

501-

16B

1

BM

D-1

514-

16B

1

BM

D-1

504-

16B

1

BM

D-1

517-

16B

1

BM

D-1

507-

16B

1

BM

D-1

513-

16B

1

BM

D-1

503-

16B

1

BM

D-1

515-

16B

1

BM

D-1

505-

16B

1

BM

D-1

512-

16B

1

BM

D-1

502-

16B

1

Cl- (

mg

/L)

Lab. Code

Cons. value (X)

X+2SDPA

X+3SDPA

X-2SDPA

X-3SDPA

Cons. value = 107.18 mg/LAlgoritma A Mean ISO 13528:2005(E)SDPA = 3.84 mg/L (SD Robust)SD Horwitz = 8.49 mg/L

©BMD Laboratory

Gambar 3. Grafik Hasil Uji Banding Parameter Klorida (Cl-)

V. PENUTUP

Program uji banding antar laboratorium merupakan salah satu sarana jaminan mutu

eksternal bagi laboratorium pengujian dan kalibrasi. Hasil dari program uji banding ini

diharapkan dapat digunakan sebagai sarana evaluasi bagi laboratorium untuk meningkatkan

kinerja dalam kegiatan pengujian yang dilakukan.

VI. REFERENSI

[1] T. Harter (2003) Reference: Groundwater Quality and Groundwater Pollution,

Publication 8084, NRCS, University of California

[2] SNI ISO/IEC 17025:2008

[3] ISO 13528:2005(E)

Page 16: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 12 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

[4] Distribution AnalyzerTM, Copyright © by Taylor Enterprises, Inc. USA

[5] M. Thompson (2004) The Amazing Horwitz Function, AMC Technical Brief No.17, Royal

Society of Chemistry

Page 17: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 13 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

Annex A

Rekapitulasi Hasil z-score Program Uji Banding

No. Kode Peserta z-score

Nitrat (NO3-) Sulfat (SO4

2-) Klorida (Cl

-)

1. BMD-1501-16B1 -0.15 OK -1.29 OK -0.90 OK

2. BMD-1502-16B1 2.27 $ -0.09 OK 1.73 OK

3. BMD-1503-16B1 -2.54 $ -0.57 OK 0.37 OK

4. BMD-1504-16B1 0.39 OK 0.69 OK -0.22 OK

5. BMD-1505-16B1 5.90 $$ 1.15 OK 0.91 OK

6. BMD-1506-16B1 -0.81 OK -1.12 OK -1.10 OK

7. BMD-1507-16B1 -1.11 OK 0.93 OK -0.09 OK

8. BMD-1511-16B1 -0.10 OK -1.14 OK -0.97 OK

9. BMD-1512-16B1 2.23 $ -0.07 OK 1.69 OK

10. BMD-1513-16B1 -2.47 $ -0.14 OK -0.02 OK

11. BMD-1514-16B1 0.35 OK 0.69 OK -0.25 OK

12. BMD-1515-16B1 6.74 $$ 1.25 OK 0.58 OK

13. BMD-1516-16B1 -0.80 OK -1.05 OK -1.10 OK

14. BMD-1517-16B1 -0.70 OK 0.75 OK -0.22 OK

Keterangan:

OK : Kategori ‘memuaskan’

$ : Kategori ‘meragukan’

$$ : Kategori ‘kurang memuaskan’

Page 18: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 14 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

-30.00

-20.00

-10.00

0.00

10.00

20.00

30.00

b (

mg

/L)

Lab. Code

Parameter Sulfat (SO42-)

-75.00

-55.00

-35.00

-15.00

5.00

25.00

45.00

65.00

85.00

b (

mg

/L)

Lab. Code

Parameter Nitrat (NO3-)

Annex B

Rekapitulasi Bias Nilai Peserta Terhadap Nilai Konsensus

Page 19: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 15 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

-20.00

-18.00

-16.00

-14.00

-12.00

-10.00

-8.00

-6.00

-4.00

-2.00

0.00

2.00

4.00

6.00

8.00

10.00

12.00

14.00

16.00

18.00

20.00

b (

mg

/L)

Lab. Code

Parameter Klorida (Cl-)

Page 20: LAPORAN PROGRAM UJI BANDING (PROFICIENCY · PDF fileprogram uji banding (proficiency test) antar laboratorium skema khusus semester i-2016 bahan uji: air permukaan vi batch 1 (apds

Page 16 of 16

FR.06 Laporan Program Uji Banding (Final Report)

Ed./Rev./Date: 01/03/02-01-2016

Ref. No. 003/UR/BMD/2016

BMD Laboratory–Provider of Proficiency Testing Program

Head Office: BMD Building Centre Jl. Puspiptek Raya No. 74B RT.01 RW.01 (Viktor) Serpong, Tangerang Selatan 15316

Tlp: 021-7563091 Fax: 021-7563291 Mobile: 0813 1516 2493 Email: [email protected]

www.ujiprofisiensi.com

Annex C

Evaluasi Distribusi Normal Data Program Uji Banding

Normal Distribution Analysis

(Parameter NO3-)

Powered by:

Distribution AnalyzerTM

(licensed software)

©Taylor Enterprises, Inc.

No Kode PesertaNilai Laporan

Peserta (mg/L)

1 BMD-1501-16B1 47.762 BMD-1502-16B1 69.523 BMD-1503-16B1 26.254 BMD-1504-16B1 52.605 BMD-1505-16B1 102.176 BMD-1506-16B1 41.827 BMD-1507-16B1 39.12

8 BMD-1511-16B1 48.199 BMD-1512-16B1 69.22

10 BMD-1513-16B1 26.9111 BMD-1514-16B1 52.3212 BMD-1515-16B1 109.7813 BMD-1516-16B1 41.9614 BMD-1517-16B1 42.84

Sample Size = 14Average = 55.033Standard Deviation = 24.977Skewness = 1.25Excess Kurtosis = 1.02

Test of Fit: p-value = 0.0784 (SK All) Decision = Pass (SK Spec) Decision = No specs

With 95% confidence more than 99% of the values are between -43.7495 and 153.8153

26.2500 109.780068.0150

Normal Distribution Analysis

(Parameter NO3-)

Powered by:

Distribution AnalyzerTM

(licensed software)

©Taylor Enterprises, Inc.

No Kode PesertaNilai Laporan

Peserta (mg/L)

1 BMD-1501-16B1 79.292 BMD-1502-16B1 87.923 BMD-1503-16B1 84.464 BMD-1504-16B1 93.595 BMD-1505-16B1 96.906 BMD-1506-16B1 80.57 BMD-1507-16B1 95.33

8 BMD-1511-16B1 80.389 BMD-1512-16B1 88.10

10 BMD-1513-16B1 87.6011 BMD-1514-16B1 93.5912 BMD-1515-16B1 97.5813 BMD-1516-16B1 81.0014 BMD-1517-16B1 94.00

Sample Size = 14Average = 88.589Standard Deviation = 6.623Skewness = -0.12Excess Kurtosis = -1.59

Test of Fit: p-value = 0.0763 (SK All) Decision = Pass (SK Spec) Decision = No specs

With 95% confidence more than 99% of the values are between 62.3946 and 114.7825

79.2900 97.580088.4350

Normal Distribution Analysis

(Parameter Cl-)

Powered by:

Distribution AnalyzerTM

(licensed software)

©Taylor Enterprises, Inc.

No Kode PesertaNilai Laporan

Peserta (mg/L)

1 BMD-1501-16B1 103.722 BMD-1502-16B1 113.823 BMD-1503-16B1 108.604 BMD-1504-16B1 106.335 BMD-1505-16B1 110.666 BMD-1506-16B1 102.987 BMD-1507-16B1 106.85

8 BMD-1511-16B1 103.489 BMD-1512-16B1 113.66

10 BMD-1513-16B1 107.1011 BMD-1514-16B1 106.2412 BMD-1515-16B1 109.4213 BMD-1516-16B1 102.9814 BMD-1517-16B1 106.35

Sample Size = 14Average = 107.299Standard Deviation = 3.599Skewness = 0.61Excess Kurtosis = -0.43

Test of Fit: p-value = 0.5262 (SK All) Decision = Pass (SK Spec) Decision = No specs

With 95% confidence more than 99% of the values are between 93.0658 and 121.5327

102.9800 113.8200108.4000