R91
R92
R9E
R9D
R9B
R9A
R9C
5750G
REE
N W
ALL
PLANTER
1101
3AD6000002-08
EXTRUDED ALUMINIUMPOWDERCOATED CHANNEL
EXTRUDED ALUMINIUMPOWDERCOATED CHANNEL
STEEL FRAME WITH ANODIZEDALUMINIUM MESH
CURVED GLASS BALUSTRADEIN POWDERCOATEDALUMINIUM FRAM
1100MM RAISED PLANTER DAVIT ARM POSITION
DAVIT ARM POSITION
GREEN WALL - STEEL FRAMEWITH MESH FOR PLANTINGBY LANDSCAPE ARCHITECTSOVER RAISED PLANTER
GREEN WALL - STEEL FRAME WITHMESH FOR PLANTING OVER 1100RAISED PLANTER
GRAVEL
EXTRUDED ALUMINIUMPOWDERCOATED CHANNEL
GAZEBO
5AD6000002-08
ROOF OVERSHOWN DASHED
ART SCREEN LOCATION
CURVED GLASS BALUSTRADEIN POWDERCOATEDALUMINIUM FRAME
GRAVEL
GRAVEL
600
MM
RA
ISE
D P
LAN
TER
BENCH
GREEN WALL - STEEL FRAMEWITH MESH FOR PLANTING BYLANDSCAPE ARCHITECTS
STEEL COLUMN TOSTRUCTRUL ENG. DETAILS
STEEL COLUMN TOSTRUCTRUL ENG. DETAILS
CONCRETE BASE TO COLUMNUP TO 1100MM WALL HEIGHTWITH STEEL FOOTING TOSTRUCTURAL ENG. DETAILS
PLA
NTE
R
PLA
NTE
RP
LAN
TER
PLANTER TO LANDSCAPEARCHITECTS DETAILS
PLANTER TO LANDSCAPEARCHITECTS DETAILS
PLANTER TO LANDSCAPEARCHITECTS DETAILS
PLANTER TO LANDSCAPEARCHITECTS DETAILS
CONCRETE BASE TO COLUMNUP TO 1100MM WALL HEIGHTWITH STEEL FOOTING TOSTRUCTURAL ENG. DETAILS
STEEL SQUARE COLUMN TOSTRUCT. ENG. DETAILS
PLANTER TOLANDSCAPE ARCH.DETAILS.
DRAINAGE PIPE IN CEILING BELOW TOHYDRAULIC DETAILS
DRAINAGE PIPE IN CEILING BELOW TOHYDRAULIC DETAILS
ACCESS DOORS INFRAME FOR ACCESSPLANTERS TBC WITHLANDSCAPE ARCHITECT
ACCESS DOORS INFRAME FOR ACCESSPLANTERS TBC WITHLANDSCAPE ARCHITECT
1500BMU PARKED POSTION
R91
R92
R9E
R9D
R9B
R9A
R9C
5750
200MM EXTRUDEDALUMINIUM POWDERCOATEDCHANNELTO GAZEBO ROOF
STEEL SUPPORT CHANNEL TOSTRUCTURAL ENGINEERSREQUIREMENTS
3AD6000002-08
1100MM RAISED PLANTER
GREEN WALL - STEEL FRAMEWITH MESH FOR PLANTINGBY LANDSCAPE ARCHITECTS
GAZEBO
GRAVEL
5AD6000002-08
STEEL FRAME WITH MESH FORPLANTING TO STRUCTURALENGINEERS REQUIREMENTS
600M
M R
AIS
ED P
LAN
TER
GREEN WALL - STEEL FRAMEWITH MESH FOR PLANTINGBY LANDSCAPE ARCHITECTS
STEEL MESH FOR PLANTERS
STAINLESS STEEL WIRES IN INNERRING OF GAZEBO TO SUPPORTPLANTS
30.0
00°
30.00
0°
30.000°
30.000°
30.000°
30.000°
FFLLevel 7 28.250
FFLLevel 8 31.550METAL CHANNEL TO GAZEBOROOF SUPPORTING PLANTS
GREEN WALL - STEEL FRAMEWITH ANODIZED ALUMNIUM MESH FORPLANTINGBY LANDSCAPE ARCHITECTS
CURVED GLASS INPOWDERCOATED ALUMINIUMBALUSTRADE
STEEL CHANNEL FORMAINTAINANCE SYSTEMTO ENGINEERS REQUIREMENTS
200MM EXTRUDED ALUMINIUMPOWDERCOATED CHANNEL
OFFWHITE CEMENT PRECAST PANELS WITHDARK GREY COLOURBACK GLAZING TOVERTICAL WINDOW ZONE
OFFWHITE CEMENTPRECAST PANELS
BAY WINDOW
GREEN WALL - STEEL FRAMEWITH MESH FOR PLANTINGBY LANDSCAPE ARCHITECTS
FFLLevel 7 28.250
FFLLevel 8 31.550METAL CHANNELS TO GAZEBOROOF SUPPORTING PLANTS
GREEN WALL - STEEL FRAMEWITH MESH FOR PLANTINGBY LANDSCAPE ARCHITECTS
CURVED GLASS IN POWDERCAOTEDALUMINIUM BALUSTRADE
STEEL CHANNEL FORMAINTAINANCE SYSTEMTO ENGINEERS REQUIREMENTS
GLASS BALUSTRADE INALUMINIUM EXTRUDED FRAME
200MM EXTRUDED ALUMINIUMPOWDERCOATED CHANNEL
VERTICAL SUPPORTS ANDMESH FOR PLANTERS
STEEL SQUARE COLUMN
FFLLevel 7 28.250
FFLLevel 8 31.550
GREEN WALL - STEEL FRAMEWITH MESH FOR PLANTINGBY LANDSCAPE ARCHITECTS
STEEL CHANNEL FORMAINTAINANCE SYSTEMTO ENGINEERS REQUIREMENTS
200MM EXTRUDED ALUMINIUMPOWDERCOATED CHANNEL
STEEL SUPPORT STRUCTURE TOSTRUCTURAL ENGINEERS REQUIREMENTS
600MM RAISED CONCRETEPLANTER
BENCH
CURVED GLASS BALUSTRADE INALUMINIUM FRAMING
METAL CHANNELS TO SUPPORT PLANTS
METAL WIRES OVER GAZEBOTO SUPPORT PLANTS
450
FFLLevel 7 28.250
FFLLevel 8 31.550
METAL CHANNELS TO SUPPORTPLANTS
1100MM RAISED CONCRETE PLANTER
200MM EXTRUDED ALUMINIUMPOWDERCOATED CHANNEL
GREEN WALL - STEEL FRAMEWITH MESH FOR PLANTINGBY LANDSCAPE ARCHITECTS
OFFWHITE CEMENT PRECAST PANELS
SUPPORT STRUCTURE TOSTRUCTURAL ENGINEERSREQUIREMENTS
9AD6000002-08
CONCRETE FOOTING UP TO WALLHEIGHT TO STEEL COLUMN
BMU PARKED POSITION
FFLLevel 7 28.250
FFLLevel 8 31.550
METAL CHANNELS TO GAZEBOROOF SUPPORTING PLANTS
GREEN WALL - STEEL FRAMEWITH MESH FOR PLANTINGBY LANDSCAPE ARCHITECTS
CURVED GLASS IN POWDERCAOTEDALUMINIUM BALUSTRADE
STEEL CHANNEL FORMAINTAINANCE SYSTEMTO ENGINEERS REQUIREMENTS
1100MM RAISED CONCRETEPLANTER
200MM EXTRUDED ALUMINIUMPOWDERCOATED CHANNEL
VERTICAL SUPPORTS ANDMESH FOR PLANTERS
METAL WIRES FOR PLANTINGOVER GAZEBOACCESS DOORS IN FRAME
TO PLANTERSACCESS DOORS IN FRAMETO PLANTERS
FFLLevel 8 31.550
PAINTED STEEL ANGLE - PA-60TO STRUCTURAL ENGINEERS REQUIREMENTS
PAINTED STEEL PLATE PA-60 TO STRUCTURAL ENG. DETIAL -65X10MM
CIRCULAR PAINTED PA-60 STEEL PROFILE TOSTRUCTURAL ENGINEERS DETAILS - 50 MM CHS
PAINTED STEEL CURVED BEAM TO STRUCTURAL TOSTRUCTURAL ENGINEERS DETAILS -150 X150 SHS
PAINTED STEEL CIRCULAR COLUMN TO STRUCTURALENGINEERS DETAILS -168.3 CHS
PAINTED STEEL PA-60 FRAME TO STRUCTURALENGINEERS DETAILS - 75MM SHS
75
75
150
200 200
50 50
ANODIZED ALUMNIUM PA-60 MESH TO LANDSCAPEARCHITECTS SPEC.
PAINTED STEEL CONNECTION
ARCHITECTURALLY PREFERRED SHAPE OF MAIN BEAM TOREDUCE VISUAL IMPACT OF SHAPE.
200
PAINTED PA-60 STEEL SECTION TO STRUCTURALENGINEERS DETAILS
www.lendlease.com
Lend Lease
Design
30 The Bond 30 Hickson RoadMillers Point NSW 2000
Project Management & Construction
Lend Lease
Lend LeaseDeveloper
Lead ArchitectsKey Plan
Date Rev. Item Revision Description Date
B1
DateDrawn By Purpose Approved By Date
RevisionDrawing No.Site No.Project No.
TitleProject
Consultant
Collaborating Architects
ItemRev. Revision Description
These designs, plans and specifications and the copyright there in arethe property of Lend Lease and must not be used, reproduced or copiedwholly or in part without the written permission of Lend Lease.
Principal
The Architect shall not be liable for any loss or claims whatsoever arising from or in respect of any errorsexisting or resulting from data howsoever transferred from the computer system of the Architect to thesystems of the Client or other Consultants.The recipient of the data shall be responsible for checking accuracy and completeness of data received.Any use of the electronic data in part or whole shall be at the users risk.
Do not scale from drawings.Verify all dimensions on site before commencing work.Copying or the reproduction of this drawing is strictly prohibited without the consent of Peddle Thorp andWalker P/L.
The CAD files and their contents are solely representations of the Project information and cannot be reliedupon beyond the representation shown on the PDF versions of the drawings as provided by the Architect.
1 520 8m
C:\R
evit_
Loca
l\212
022_
R9_v
13_R
ido Lo
cal.rv
t16
/10/20
14 6:
49:45
PM
Asindicated
Landscape_Greenwall Gazebo L7RP 18/06/14 RP 18/06/14FOR INFO
212.022 BR9AD6000002-08
1 : 50Gazebo Level 71
1 : 50Gazebo Level 82 1 : 50
Gazebo South Elevation7
1 : 50Gazebo West Elevation6
1 : 50Gazebo Section 13
1 : 50Gazebo Section 35
00 FOR INFORMATION 28/03/201301 FOR INFORMATION 15/04/201302 FOR INFORMATION 14/06/2013
1 : 50Gazebo North Section4
03 FOR INFORMATION 28/11/201304 FOR INFORMATION 10/01/2014
1 : 10Callout of Gazebo Section 39
05 FOR INFORMATION 02/05/201406 FOR INFORMATION 12/05/201407 FOR INFORMATION 18/06/201408 FOR INFORMATION 16/10/2014