3
PG 6 PG 1 Pack contents: 1 x LED floodlight with PIR complete with 3 core 1.0mm 2 x 0.8m rubber cable and quick fix mounting bracket These instructions are provided as a guideline to assist you. PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION AND RETAIN FOR FUTURE REFERENCE Model: TAB10PIRWH / TAB20PIRWH / TAB30PIRWH TAB10PIRBK / TAB20PIRBK / TAB30PIRBK 10W / 20W / 30W Tablet LED Floodlights With 120° PIR INSTALLATION INSTRUCTIONS A guide for qualified electricians 1m EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT: Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Directive” effective August 2005—UK WEEE Regulations effective 2nd January 2007). Environment Agency Registered Producer: WEE/ GA0248QZ. WHEN YOUR PRODUCT COMES TO THE END OF ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE RECYCLE IT WHERE FACILITIES EXIST - DO NOT DISPOSE WITH HOUSEHOLD WASTE. IF YOU EXPERIENCE PROBLEMS: If you believe your product is defective, please return it to the place where you bought it. Our Technical Team will gladly advise on any Eterna Lighting product, but may not be able to give specific instructions regarding individual installations. 10W Email: [email protected] / [email protected] Visit our website: www.eterna-lighting.co.uk Made in China Issue 0717 20W 30W LAMP SPECIFICATIONS: 10W 20W 30W Lumens total flux 750 lm 1500 lm 2400 lm Rated Wattage 10W 20W 30W Nominal life time of the lamp 30,000 hrs 30,000 hrs 30,000 hrs Colour temperature 4000K 4000K 4000K Number of switching cycles before premature lamp failure 15,000 15,000 15,000 Warm-up time up to 60 % of the full light output Instant full light Instant full light Instant full light Dimmable No No No LED array dimensions (L/H) 40 x 15mm 70 x 15mm 60 x 25mm Nominal beam angle 120° 120° 120° Rated power 10W 20W 30W Rated lamp lifetime 30,000 hrs 30,000 hrs 30,000 hrs Lamp power factor >0.5 >0.5 >0.9 Lumen maintenance factor at end of nominal life 70% 70% 70% Starting time <0.5s <0.5s 0.5s Colour rendering >80 >80 >80 Colour consistency Within 6 step Macadam ellipse Within 6 step Macadam ellipse Within 6 step Macadam ellipse Rated peak intensity 231.45cd 450cd 720cd Rated beam angle 120° 120° 120° Voltage 240V 240V 240V Not suitable for accent lighting

LAMP SPECIFICATIONS: 10W 20W 30W 750 lm 1500 lm ...PG 6 PG 1 Pack contents: 1 x LED floodlight with PIR complete with 3 core 1.0mm2 x 0.8m rubber cable and quick fix mounting bracket

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LAMP SPECIFICATIONS: 10W 20W 30W 750 lm 1500 lm ...PG 6 PG 1 Pack contents: 1 x LED floodlight with PIR complete with 3 core 1.0mm2 x 0.8m rubber cable and quick fix mounting bracket

PG 6 PG 1

Pack contents:1 x LED floodlight with PIR complete with 3 core 1.0mm2 x 0.8m rubber cable and quick fix mounting bracket

These instructions are provided as a guideline to assist you.

PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION AND RETAIN FOR FUTURE REFERENCE

Model: TAB10PIRWH / TAB20PIRWH / TAB30PIRWH

TAB10PIRBK / TAB20PIRBK / TAB30PIRBK10W / 20W / 30W Tablet LED Floodlights With 120° PIR

INSTALLATION INSTRUCTIONSA guide for qualified electricians

1m

EVENTUALLY, YOU MAY WANT TO REPLACE THIS PRODUCT:

Regulations require the recycling of Waste from Electrical and Electronic Equipment (European “WEEE Directive” effective August 2005—UK WEEE Regulations effective 2nd January 2007). Environment Agency Registered Producer: WEE/GA0248QZ.

WHEN YOUR PRODUCT COMES TO THE END OF ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE RECYCLE IT WHERE FACILITIES EXIST - DO NOT DISPOSE WITH HOUSEHOLD WASTE.

IF YOU EXPERIENCE PROBLEMS:

If you believe your product is defective, please return it to the place where you bought it. Our Technical Team will gladly advise on any Eterna Lighting product, but may not be able to give specific instructions regarding individual installations.

10W

Email: [email protected] / [email protected]

Visit our website: www.eterna-lighting.co.uk Made in ChinaIssue 0717

20W

30W

LAMP SPECIFICATIONS: 10W 20W 30W

Lumens total flux 750 lm 1500 lm 2400 lmRated Wattage 10W 20W 30W

Nominal life time of the lamp 30,000 hrs 30,000 hrs 30,000 hrs

Colour temperature 4000K 4000K 4000K

Number of switching cycles before premature lamp failure

15,000 15,000 15,000

Warm-up time up to 60 % of the full light output Instant full light Instant full light Instant full light

Dimmable No No No

LED array dimensions (L/H) 40 x 15mm 70 x 15mm 60 x 25mm

Nominal beam angle 120° 120° 120°

Rated power 10W 20W 30W

Rated lamp lifetime 30,000 hrs 30,000 hrs 30,000 hrs

Lamp power factor >0.5 >0.5 >0.9

Lumen maintenance factor at end of nominal life 70% 70% 70%

Starting time <0.5s <0.5s 0.5s

Colour rendering >80 >80 >80

Colour consistency Within 6 step Macadam ellipse

Within 6 step Macadam ellipse

Within 6 step Macadam ellipse

Rated peak intensity 231.45cd 450cd 720cd

Rated beam angle 120° 120° 120°

Voltage 240V 240V 240V

Not suitable for accent lighting

Page 2: LAMP SPECIFICATIONS: 10W 20W 30W 750 lm 1500 lm ...PG 6 PG 1 Pack contents: 1 x LED floodlight with PIR complete with 3 core 1.0mm2 x 0.8m rubber cable and quick fix mounting bracket

To avoid damage to the unit do not aim sensor towards sun.

Avoid positioning the sensor unit adjacent to a bright light source which may prevent the unit from operating when the lux control is set to operate in dark conditions.

Avoid nuisance / false triggering by directing sensor away from:

• Trees and shrubs • Reflective surfaces such as smooth white walls • Swimming pools • Heat sources such as boiler flues

The PIR sensor scanning specifications (approximately 7 metres at 120°) may vary slightly depending on the mounting height and location.

The detection range of the unit may also alter with temperature change. Before selecting a place to install your PIR floodlight you should note that movement across the scan area is more effective than movement directly towards or away from the sensor. (Refer to fig.2 opposite).

If movement is made walking directly towards or away from the sensor and not across the sensor the apparent detection range will be substantially reduced (refer to fig. 3 below).

INTRODUCTION:The floodlight incorporates a PIR (Passive Infra Red) sensing device which continuously scans a preset operating zone and immediately switches the light on when it detects movement in that area.

This means that whenever movement is detected within the range of the sensor the light will switch on automatically to illuminate the area you have selected to light. While there is movement within range of the unit the light will remain on.

READ THIS FIRST:Check the pack and make sure you have all of the parts listed on the front of this booklet. If not, contact the outlet where you bought this product.

This product must be installed by a competent person in accordance with the current building and IEE wiring regulations.

As the buyer, installer and/or user of this product it is your own responsibility to ensure that this fitting is fit for the purpose for which you have intended it. Eterna Lighting cannot accept any liability for loss, damage or premature failure resulting from inappropriate use.

This product is designed and constructed according to the principles of the appropriate British Standard.

Switch off the mains before commencing installation and remove the appropriate circuit fuse or lock off MCB.

This unit is suitable for outdoor use.

This product is designed for permanent connection to fixed wiring: this must be a suitable circuit (protected with the appropriate MCB or fuse).

Before making fixing hole(s), check that there are no obstructions hidden beneath the mounting surface such as pipes or cables.

Make sure that the fixings are strong enough to support the considerable weight of the fitting and hold it rigidly.

The lamp must be positioned so that there is at least 1M between the luminaire and any illuminated surface.

When making connections ensure that the terminals are tightened securely and that no strands of wire protrude. Check that the terminals are tightened onto the bared conductors and not onto any insulation.

This product must be connected to Earth termination.

This product is not intended to be used by children and persons with sensory, physical and/or mental impairments that would prevent them from using it safely.

You are advised at every stage of your installation to double-check any electrical connections you have made. After you have completed your installation

there are electrical tests that should be carried out, these tests are specified in the current IEE wiring and building regulations.

CLEANING:

• To avoid dust build-up and ensure proper functioning of the floodlight, please wipe the sensor lens lightly with a damp cloth every 3 months.

• Disconnect the power and clean the exterior only of this fitting with a moist (not wet) cloth.

• Do not use any chemical or abrasive cleaners.

SPECIFICATIONS:

• Detection range: max. 7m at approx. 120° scan

• Duration time adjustment: (10±2) seconds to (7±2) minutes

• Sensitivity adjustment: 2m to 7m

• Detection circuitry: Passive Infra-Red (PIR)

• Weatherproof: IP44

• Power required: 230V ~ 50 Hz

• Recommended power supply cable: H05RN-F 3G 1.0mm2

• Lux adjustment: 2-2000 Lux

WHERE TO FIT YOUR PIR FLOODLIGHT:To achieve best results we suggest you take the following points into consideration:

Do not mount on a surface that has vibration.

Ideally the PIR flood light should be mounted 1.8 to 2.5 metres (6 to 8ft) above the area to be scanned (refer to fig.1 below).

2.5M

2M 5M 7M

120˚ApproxFig 1

EFFECTIVE:Movement acrossscan area

LESS EFFECTIVE:Movement directly in front of scan area

Fig 2

Fig 3

PG 2 PG 3

874/2012

MODELNO.TABLET RANGEFixing slots on bracket

10W: 44mm20W: 75mm30W: 119mm

Page 3: LAMP SPECIFICATIONS: 10W 20W 30W 750 lm 1500 lm ...PG 6 PG 1 Pack contents: 1 x LED floodlight with PIR complete with 3 core 1.0mm2 x 0.8m rubber cable and quick fix mounting bracket

INSTALLATION:01) Switch off the mains before commencing

installation.

02) Using the bracket as a template mark and then drill the appropriate fixing holes.

03) Secure the bracket with suitable fixings.

04. Terminate loose ends of wire to an appropriate IP rated junction box or similar, ensuring the below is observed. Live - Brown / Red Neutral - Blue / Black Earth - Yellow / Green

05) Adjust the direction of the floodlight and tighten the head fixings ensuring that you have used the lock washers.

06) Restore mains power.

07) Adjust the PIR sensor floodlight to the desired settings.

UNDERSTANDING THE CONTROLS: (Please refer to Fig. 5 below)

ADJUSTING THE DURATION TIME: The length of time the unit remains switched on after activation can be adjusted from (10±2) seconds to (7±2) minutes approximately. Rotating the TIME screw from (+) to (-) will reduce the duration time.

Note: Once the light has been triggered by the PIR sensor any subsequent detection will start the timed period again from the beginning.

ADJUSTING THE LUX CONTROL LEVEL: The Lux control module has a built-in sensing device (photocell) that detects daylight and darkness. The (R) position denotes that the floodlights can work at day and night, and the () position only work at night. You can set to operate the unit at the desired level by adjusting the LUX screw.

SETTING THE CONTROLS - WALK TEST:Turn the Lux control screw to light (R) & ensure that the TIME control screw is set at the minimum duration time (-) position. The floodlight will now switch on and remain on for about 10 seconds after each detection.

01) Adjust time control to required setting.

02) To set the light level at which the floodlight will automatically switch “on” at night, turn the LUX control screw from daylight (R) to night (). If the floodlight is required to switch on earlier, e.g. dusk, wait for the desired light level, then slowly turn the LUX control screw towards daylight while someone walks across the center of the area to be detected. When the floodlight switches on stop adjusting. You may need to make further adjustments to achieve your ideal light level setting.

ADJUSTING THE SENSITIVITY:The sensitivity means the maximum distance which PIR sensor can be triggered by movement - turning the SENS knob from (+) to (-) will decrease the sensitivity.

TROUBLESHOOTING AND USER HINTS:Note: all passive infra red detectors are more sensitive in cold and dry weather than warm and wet weather.

PROBLEM POSSIBLE CAUSE SUGGESTED REMEDY

Light does not switch on when there is movement in the detection area.

1. No mains voltage Check all connections, and MCB Fuses / switches

2. Nearby lighting is too bright Relocate the unit

3. Controls set incorrectly Adjust Lux setting

4. Wired incorrectly Check wiring and confirm its wired as per the wiring instructions opposite

5. Sensor positioned in wrong direction Relocate the unit

Light switches on for no apparent reason (false trigger)

1. Heat sources such as air-con, vents, heaters, flues, other outside lighting, moving cars trees or shrubs are activating sensor

Relocate the unit

2. Interference from on/off switching of electric fans or lights on the same circuit as your security floodlight.

(This problem does not always occur but a faulty switch or noisy fluorescent light may cause the security floodlight to switch on)

Should the false triggering become, troublesome, consider:

(a) Replacing a faulty switch

(b) Replacing noisy fluorescent tubes and/or starters

(c) Connecting the floodlight to a separate circuit (in most cases where one or more of the above suggestions have been carried out, false triggering has been reduced)

3. Reflection from swimming pool, or reflective surface such as smooth white walls Relocate the unit

Light remains on Time is set too long Reduce time

Light remains on at nighttime Possible heat source in detection zone

Cover PIR sensor lens with a thick cloth, if the light turns off check detection area for heat or reflective source, reposition head and decrease the sensitivity setting if this control is available

Light switches on during daylight hours LUX control screw is set to daylight position Turn the LUX control screw to desired light level

setting

When setting the lux controls in daylight the detection distance becomes shorter

Interference by sunlight Re-test at night

Fig 5: PIR Controls

PG 4 PG 5

TIME LUXSENS

LAMP REPLACEMENT:

The light source contained in this luminaire shall only be replaced by the manufacturer, service agent or a similar qualified person. CAUTION, RISK OF ELECTRIC SHOCK.