LabFit
Lab�t
CS2000
Simplifying Carbon & Sulphur Analysis
Quality. Innovation. Reliability.
CS2000 Carbon & Sulphur
Hardware Features
99 HIGH-TECH CERAMICS9prevent9tube9cracking9&9crucible9jams
99 THROUGHPUT carousel9holds9up9to9489samples
99 LATEST Infrared9Technology
99 EFFICIENT furnace9design
99 VERTICAL tube9resistance9furnace
99 MAINTENANCE simplified9design
99 METHODS unlimited.9Mixed9methods9possible9for9all9applications
99 INTELLIGENT end9of9analysis9calculations
99 LINEARISATION performed9within9software
99 DIAGNOSTICS comprehensive9and9friendly
99 LIMS full9compatibility9with9all9LIMS9systems
Applications
MINERAL ORES
COALS & COKES
CRACKING CATALYST
SOILS & PLANTS
OILS &
ORGANIC MATERIALS
The9 CS20009 Carbon9 &9 Sulphur9 instruments9 utilise9 the9 latest9 in9 infrared9technology9 to9 determine9 the9 concentration9 of9 the9 sample.9 The9 system9uses9 a9 vertical9 resistance9 furnace9 design9 to9 eliminate9 the9 problems9associated9with9traditional9horizontal9tube9furnaces.9The9advantage9of9 the9 vertical9 furnace9 is9 that9 thermal9 chock9 caused9 by9 cold9combustion9 crucibles9or9boats9do9not9 come9 into9 contact9with9the9hot9combustion9tube.9The9CS20009includes9a9489position9autosampler9as9standard9with9the9analysed9crucibles9being9placed9back9into9their9original9position.
Software FeaturesThe9powerful9linearisation9feature9set9of9the9CS20009allows9for9multiple9curve9fitting9for9different9methods.9This9means9that9the9range9of9the9infrared9can9be9pushed9increasing9sensitivity9at9either9the9 low9or9high9end9of9 the9spectrum.9The9software9 includes9the9tools9needed9to9effectively9quantify9the9results9using9the9in9built9statistical9functions.9The9system9uses9a9comprehensive9end9of9analysis9determination9algorithm9so9samples9always9 finish9 as9 expected.9 Production9 “Spot”9 samples9 are9 easily9 achieved9with9 out9disturbing9the9normal9operation9of9the9CS2000.9Our9new9LIMS9compatibility9feature9set9provides9the9power9to9the9IT9department9for9LIMS9connectivity.
CS2000 Specifications
LabFit
Lab�t
LabFit Pty LtdPO Box 343, Burswood
Perth, Western Australia 6100
Tel: +618 9361 2228Fax: +618 9361 2216
E-mail: [email protected]: www.labfit.com
Local Distributor:
GENERALDIMENSIONS 850mm Wide x 700mm Deep x 920mm High
WEIGHT 1409KgANALYSER POWER Single9phase92309VAC9+/-910%,950/60Hz
3A9/9209WFURNACE POWER Single9phase9220-230VAC9+/-10%950/60Hz
Maximum9heat9current925APOWER CONSUMPTION 6.2kW9
FURNACE TEMPERATURE Ambient9to91450°CBALANCE Sartorius9analytical90.1Mg
GASES Oxygen999.5%9pure,93l/min9300kPaCompressed9air,9dry9&9clean9600kPa
CHEMICALS H₂O9Trap,9Magnesium9Perchlorate
ANALYSISNOMINAL SAMPLE WEIGHTS Coal9&9Coke,9300Mg
Mineral9Ores,9up9to91gramSoils9&9Plants,9up9to919gramOils9(Diesel),9300Mg9(reduction9in9temperature)
NORMAL ANALYSIS TIME 60-1209SecondsACCURACY Carbon,9+/-91%9of9the9element9present
Sulphur,9+/-91%9of9the9element9presentSENSITIVITY Carbon,90.01%9based9on919gram9sample
Sulphur,90.01%9based9on919gram9sample
MEASURING RANGESLOW CARBON 0-2%9C,9based9on919gram9sample
HIGH CARBON 2-10%9C,9based9on919gram9sampleLOW SULPHUR 0-2%9S,9based9on919gram9sample
HIGH SULPHUR 2-8%9S,9based9on919gram9sample
CONFIGURATIONSCARBON & DUAL RANGE SULPHUR Carbon9&9Low9Sulphur
CARBON & HIGH SULPHUR Carbon9OnlyDUAL RANGE SULPHUR High9Sulphur9Only
LOW SULPHUR ONLY Low9Carbon��Low9Carbon9is9availably9upon9request9on9any9of9the9configuration9listed9above.