1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic stripper for measuring diesel solid nanoparticles Zhongqing Zheng 1 , Kent C. Johnson 1 , Zhihua Liu 1 , Thomas D. Durbin 1 , Shaohua Hu 2 , Tao Huai 2 , David B. Kittelson 3 , Heejung S. Jung 1 1 University of California, College of Engineering, Center for Environmental Research and Technology (CE-CERT), Riverside, CA 92521 2 California Air Resources Board (CARB), 1001 I Street, Sacramento, CA 95814 3 University of Minnesota, Department of Mechanical Engineering, 111 Church St. SE, Minneapolis, MN 55455 Introduction Progress in regulating diesel particle emissions by non-gravimetric means has been made in Europe. The United Nations Economic Commission for Europe-Group of Experts on Pollution and Energy (UNECE-GRPE) initiated the Particle Measurement Programme (PMP) working group to develop new particle measurement techniques to supplement or replace the current gravimetric method. The PMP protocol specifies measuring solid particles larger than 23 nm. During previous California Air Resource Board (CARB)/UCR’s studies of the PMP, a significant number of appeared-to-be solid sub-23 nm particles were found downstream of the PMP volatile particle remover under conditions that were thought to be unlikely to form sub-23 nm solid particles (1, 2). This study presents laboratory and vehicle experiments of diesel particle penetration/formation using the PMP system and CS. Experimental Laboratory Test Setup and Procedure For the laboratory tests, aerosols with four different compositions were utilized to evaluate the response of the APC and CS systems under controlled conditions. The aerosol compositions included pure sulfuric acid, pure tetracosane (C 24 n-alkane), a mixture of sulfuric acid and tetracosane, and a mixture of sulfuric acid and tetracontane (C 40 n-alkane). Chassis Dynamometer Test For the chassis dynamometer tests, the APC and CS were tested with exhaust generated by driving a heavy-duty truck on a chassis dynamometer. Figure 1 shows the schematic of experimental setup. Results and Discussions Laboratory test When aerosol composed of a mixture of sulfuric acid and tetracosane was used, the APC and CS removed 99.8% and 99.4% particles, respectively. For the APC-CS test, no particles were seen downstream of the APC-CS when aerosol composed of pure sulfuric acid or pure tetracosane were used. When using aerosol composed of a mixture of sulfuric acid and tetracosane for the APC-CS test, however, 14.2% of particles seen downstream the APC were observed downstream the APC-CS by number concentration, indicating at least 14.2% of those particles downstream of the APC were non-volatile. Chassis dynamometer test Negligible number of particles between 10 and 23 nm were present downstream the APC and CS. Due to thermophoretic loss, the CS reported ~40% less PN emissions than the APC for particles > 10 nm. PN emissions of particles between 3 and 10 nm downstream the APC were ~

Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Embed Size (px)

Citation preview

Page 1: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

1

 

Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic stripper for measuring diesel solid nanoparticles Zhongqing Zheng1, Kent C. Johnson1, Zhihua Liu1, Thomas D. Durbin1, Shaohua Hu2, Tao Huai2, David B. Kittelson3, Heejung S. Jung1 1University of California, College of Engineering, Center for Environmental Research and Technology (CE-CERT), Riverside, CA 92521 2California Air Resources Board (CARB), 1001 I Street, Sacramento, CA 95814 3University of Minnesota, Department of Mechanical Engineering, 111 Church St. SE, Minneapolis, MN 55455 Introduction

Progress in regulating diesel particle emissions by non-gravimetric means has been made in Europe. The United Nations Economic Commission for Europe-Group of Experts on Pollution and Energy (UNECE-GRPE) initiated the Particle Measurement Programme (PMP) working group to develop new particle measurement techniques to supplement or replace the current gravimetric method. The PMP protocol specifies measuring solid particles larger than 23 nm. During previous California Air Resource Board (CARB)/UCR’s studies of the PMP, a significant number of appeared-to-be solid sub-23 nm particles were found downstream of the PMP volatile particle remover under conditions that were thought to be unlikely to form sub-23 nm solid particles (1, 2). This study presents laboratory and vehicle experiments of diesel particle penetration/formation using the PMP system and CS. Experimental Laboratory Test Setup and Procedure

For the laboratory tests, aerosols with four different compositions were utilized to evaluate the response of the APC and CS systems under controlled conditions. The aerosol compositions included pure sulfuric acid, pure tetracosane (C24 n-alkane), a mixture of sulfuric acid and tetracosane, and a mixture of sulfuric acid and tetracontane (C40 n-alkane). Chassis Dynamometer Test

For the chassis dynamometer tests, the APC and CS were tested with exhaust generated by driving a heavy-duty truck on a chassis dynamometer. Figure 1 shows the schematic of experimental setup. Results and Discussions Laboratory test

When aerosol composed of a mixture of sulfuric acid and tetracosane was used, the APC and CS removed 99.8% and 99.4% particles, respectively. For the APC-CS test, no particles were seen downstream of the APC-CS when aerosol composed of pure sulfuric acid or pure tetracosane were used. When using aerosol composed of a mixture of sulfuric acid and tetracosane for the APC-CS test, however, 14.2% of particles seen downstream the APC were observed downstream the APC-CS by number concentration, indicating at least 14.2% of those particles downstream of the APC were non-volatile. Chassis dynamometer test

Negligible number of particles between 10 and 23 nm were present downstream the APC and CS. Due to thermophoretic loss, the CS reported ~40% less PN emissions than the APC for particles > 10 nm. PN emissions of particles between 3 and 10 nm downstream the APC were ~

Page 2: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

2

 

2 and 7 times higher than the PN emissions of particles above 10 nm at the 74 and 26% engine load, respectively. At the 26% engine load, PN level of the 3 to 10 nm particles downstream the APC were even higher than that in the dilution tunnel, suggesting the APC was making 3 to 10 nm particles. Much less particles between 3 to 10 nm were seen downstream the CS for both engine loads. The PN emission of 3 to 10 nm particles downstream the APC was related to the heating temperature of the APC evaporation tube (Figure 2).

Figure 1 Schematic of chassis dynamometer test setup

Figure 2 CPC concentrations vs ET temperature

References (1) Johnson, K. C.; Durbin, T. D.; Jung, H.; Chaudhary, A.; Cocker, D. R.; Herner, J. D.; Robertson, W. H.; Huai, T.; Ayala, A.; Kittelson, D. Evaluation of the european pmp methodologies during on-road and chassis dynamometer testing for dpf equipped heavy-duty diesel vehicles. Aerosol Science and Technology 2009, 43, (10), 962 - 969. (2) Herner, J. D.; Robertson, W. H.; Ayala, A. Investigation of ultrafine particle number measurements from a clean diesel truck using the european pmp protocol. SAE International 2007.

Page 3: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Measurement of diesel solid nanoparticle emissions using a catalytic stripper for

comparison with Europe’s PMP protocol

Heejung Jung, Zhongqing Zheng, Kent C. Johnson, Zhihua Liu, and Thomas D. Durbin University of California, Riverside

David B. KittelsonUniversity of Minnesota

Shaohua Hu and Tao HuaiCalifornia Air Resources Board

Page 4: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Particle measurement programme

2

PMP system

Red: Semivolatile particlesBlack: Solid (mostly soot) particles

Page 5: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Why only particles larger than 23nm?

Figures courtesy of D. Kittelson 0

0.05

0.1

0.15

0.2

0.25

1 10 100 1,000 10,000

Diameter (nm)

Nor

mal

ized

Con

cent

ratio

n (1

/Cto

tal)d

C/d

logD

p

Number Surface Mass

Fine ParticlesDp < 2.5 m

Ultrafine ParticlesDp < 100 nm

NanoparticlesDp < 50 nm

Nuclei Mode - Usually forms from volatile precursors as exhaust dilutes and cools

Accumulation Mode - Usually consists of carbonaceous agglomerates and adsorbed material

Coarse Mode - Usually consists of reentrained particles, crankcase fumes

PM10Dp < 10 m

In some cases this mode may consist of very small particles below the range of conventional instruments, Dp < 10 nm

PM2.5

23 nm

•D50=23 ensures soot particles are measured but limits detection of any nucleation mode particles that escape the evaporation tube. Giechaskiel et al. (2009) SAE 2009-01-1767

Figures courtesy of H. Burtscher (2005)

•Sulfate>HC> AmmoniumBiswas et al. (2009)

Page 6: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Issues with not counting sub 23nm particles

www.cert.ucr.edu4

Page 7: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Engine out, light-load, low soot conditions: Most of the number emissions are solid with Dp < 23 nm

0.0E+00

1.0E+07

2.0E+07

3.0E+07

4.0E+07

5.0E+07

6.0E+07

1 10 100 1000Dp (nm)

dN

/dlo

gDp (

par

t/cm

3 )

Mode 1 solid

Mode 2 solid

Mode 5 solid

Carbonaceous soot

Ash

Cummins 2004 ISM engine, BP 50 fuel, AVL modes

CPC cutoff

Courtesy of Dr. Kittelson

Page 8: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Spark ignition engines can also produce tiny solid nanoparticles, especially with metal additives

0.0E+00

1.0E+07

2.0E+07

3.0E+07

4.0E+07

1 10 100 1000Dp, nm

dN

/dlo

gDp

, par

t/cm

3

Transient EUDC Manganese solid

Idle Manganese solid

50 kph Manganese solid

Euro 3 passenger car, 10 ppm Mn in fuel, data courtesy Johnson-Matthey

CPC cutoff

Courtesy of Dr. Kittelson

Page 9: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Objective

• Investigation of the nature of sub 23nm particles downstream the PMP system

• Evaluation and comparison of the PMP and CS

7

Page 10: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Results

8

Page 11: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Test conditions• Comparisons of fully compliant PMP system with measurement

system using catalytic stripper for volatile particle removal– Use a variety of counting instruments with different lower size cutoffs

• TSI 3022 – 7 nm• TSI EEPS – 6 nm• TSI 3790 – 23 nm• TSI 3772 – 10 nm• TSI 3025A – 3 nm• TSI 3776 – 2.5 nm

– Tests with exhaust aerosols from heavy-duty vehicle operating on chassis dynamometer

• Freightliner class 8 truck with 14.6 liter, 2000 Caterpillar C-15 engine, equipped with Johnson Matthey Continuously Regenerating Trap (CRTTM)

• Two steady state cruise conditions, constant speed 56 mph at 26% and 74% of full load

– Tests with laboratory challenge aerosols

Page 12: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Chassis test

CVS

CPC 3772

CPC 3776

CPC 3025A

nano-SMPS

to vacuum

needle valve

vent

rotameter

heated line

fast-SMPS

ejectorventuri

CPC 3772_CS

compressed air

vent

ball valve

EEPS

CPC 3022A_CVS

cyclone particle cut point 2.5 µm

Alternate between the APC and CS

DR=21

DR=100 or 500

PMP system (=APC)

1st dilution 2nd dilutionET CPC

3790

Page 13: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

CVS particle size dist. measured by EEPS

74% engine load

11

Time (s)

Dp

(nm

)

Dp

(nm

)

dN/dlogDp (#/cc)

EEPS data near noise level at 26% engine load

26% engine load

Page 14: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

The PMP compliant system closely tracks the accumulation mode (74% load)

CPC D50(nm)

3790_APC 23

3772_CS 10

3025A 3

3772 10

3776 2.5

Page 15: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Comparison of instruments at 74% load cruise

• Downstream of PMP system– 3790 and 3772 agree – no particles between 10 and 23 nm– 3025A and 3776 agree and read progressively higher than 3772 and 3790 as time goes

on – particles forming between 3 and 10 nm– Same trend at 100 and 500 dilution ratio

• Downstream of CS– In first time window all instruments agree – no particle below 23 nm– In second and third time windows 3776 and 3025A read higher than 3772 – particle

formation between 3 and 10 nm

CPC D50(nm)

3790_APC 23

3772_CS 10

3025A 3

3772 10

3776 2.5

Page 16: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Comparison of instruments at 26% load cruise

• Much lower concentrations than at 74%

– Downstream of PMP system• In first time window, DR = 500

– 3790 and 3772 agree – no particles between 10 and 23 nm

– 3776 and 3025A read much higher and disagree – many particles below lower cutoff size of these instruments, 2.5 to 3 nm

• In second time window, DR = 100– 3790 and 3772 read higher but agree – no

particles between 10 and 23 nm but formation above 23 nm

– 3776 and 3025A agree but read only slightly higher than 3790 and 3772 – nearly all particles have grown to above 23 nm

– Downstream of CS • Consistently lower reading and

agreement between instruments• In last time window instruments

bypass volatile particle removal systems and are directly connect to CVS – measure total solid and volatile particles – fewer particles than DR = 500 APC, clear evidence of particle formation by APC

Page 17: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Nano SMPS measurement74% load 26% load

Page 18: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

1st dilutionat PMP (150C)

2nd dilutionat PMP

Evaporation tube(300C)

PMP (=APC)Upstream of CS Downstream of CSUpstream of PMP

H2SO4+HC

H2SO4

HC (C24 or C40)

0.1%

1%

0.6%

PMP(=APC)

0%

0%

0.55%

CS

Lab test (smilar to Swanson and Kittelson)

Penetration efficiency by total particle number

Page 19: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

APC ET temperature oscillation

17

Chassis test (74% load)

1st dilution 2nd dilutionET

PMP (=APC)

CPC3790

Lab test

(23nm)

(23nm)

(3nm)

1st dilution 2nd dilutionET

PMP (=APC)

CPC3790

CVS

Cyclone

CPC3776

Page 20: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Conclusion• Volatile remover such of the PMP system and the CS makes

substantial number of sub 10nm particles.• The sub 10 nm particles downstream the PMP were formed in the

PMP system, because:– Particle concentration of those sub 10 nm particles oscillated in relation

with the oscillation of the PMP ET temperature.– Some of these appeared to be solid as they could not be removed by

the CS in the lab experiment others appear to be semivolatile as they fluctuate along with ET temperature.

18

Page 21: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Implication and future work

• The PMP works fine with D50=23nm, but if PMP needs to measure ash particles and be applied more widely with a lower or no cutoff diameter then the PMP needs to be improved not to make artifact particles.

• New D50 for PMP=10nm?

• Do sub 10nm particles exist in other vehicles and cycles? – e.g. HD 2010 compliant OEM, GDI, & transient cycles– More experiments are needed.

• More controlled study (e.g. lab study) is needed to better understand the particle formation process.

Page 22: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Acknowledgements• CARB

– For funding and instruments.– A. Ayala and J. Herner for encouraging this study.

• AVL LIST GmbH Inc.– Providing an AVL particle counter and technical support.– B. Giechaskiel, M. Linke, R. Frazee, S. Roeck, & W. Silvis

• UCR/CE-CERT – D. Pacocha, J. Valdez, and E. O’ Neil– P. Ziemann and D. Cocker

• University of Minnesota– J. Swanson

• Johnson Matthey– M. Twigg (For catalysts to assemble the catalytic stripper)

20

Page 23: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Four papers raise issues about solid particle measurements, especially when applied to particles smaller than 23 nm

• Work done at University of California, Riverside, CE-CERT– Johnson et al. (2009). Evaluation of the European PMP Methodologies

during On-Road and Chassis Dynamometer Testing for DPF Equipped Heavy Duty Diesel Vehicles, Aerosol Science and Technology, 43:962–969, 2009.

– Zheng et al. (2011). Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic stripper for measuring diesel solid nanoparticles, submitted to Journal of Aerosol Science.

• Work done at the University of Minnesota, CDR– Swanson and Kittelson (2010). Evaluation of thermal denuder and

catalytic stripper methods for solid particle measurements, Journal of Aerosol Science, Volume 41, Issue 12, Pages 1113-1122.

• Work done at California Air Resources Board– Herner et al. (2007). Investigation of ultrafine particle number

measurements from a clean diesel truck using the European PMP protocol, SAE 2007-01-1114

Page 24: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Thank You

22

Page 25: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Backup slides

www.cert.ucr.edu23

Page 26: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Conclusions• Current PMP method regulates “solid” particles larger than 23 nm

– For engines equipped with particle filters regulating to 23 nm effectively regulates all sizes

– Under extreme conditions false counts of nucleated semi-volatile have been observed

– For engines without filters (advanced fuels, combustion modes, gasoline) there may be large concentrations of solid particles below 23 nm that are not counted by current method

• Extending solid PM measurements to 10 nm– No significant semi-volatile formation downstream of catalytic stripper in

this size range

• Extending solid PM measurements to below 10 nm – problematic– Particles as small as sub 3 nm formed in large concentrations

downstream of PMP VPR– Some evidence of solid particle formation by thermal denuder– Sub 10 nm particle formation observed downstream of CS under some

conditions

Page 27: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Experimental conditionsBase CE-CERT HD Chassis dynamometer

Vehicle Freightliner class 8

Engine Caterpillar C-15 (14.6L)

Fuel ULSD (8ppm S)

Lubricating oil SAE 15W-40 (2900 ppm S)

DPF JM CRT

Vehicle weight 65,000 lb

Truck mileage 41442 miles

Cycles (a) 56 mph cruise at 74% engine load;

(b) 56 mph cruise at 26% engine load.25

Page 28: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Catalytic stripper (CS)

Oxidation catalyst: Wall temperature: 300°C Length: 11 cm Diameter: 3.2 cm 75 g/ft3 of Pt

Particle penetration 5% at 3 nm 75% at 100 nm

Sulfur‐trap (S‐Trap): Wall temperature:  300°C  Length:  11 cm Diameter: 3.2 cm BaO + SO3 BaSO4

Kittelson D.B.; Stenitzer, M. A New Catalytic Stripper for Removal of Volatile Particles. 

7th ETH Conference on Combustion Generated Particles, Zurich, 18–20th August, 2003

Page 29: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Penetration efficiency

Page 30: Laboratory and chassis dynamometer evaluation of an ... · 1 Laboratory and chassis dynamometer evaluation of an European PMP compliant particle number measurement system and catalytic

Integrated particle number emissions

1.0E+10

1.0E+11

1.0E+12

1.0E+13

1.0E+14

26% engine load 74% engine load

Par

ticl

e nu

mbe

r em

issi

on (

# / k

Wh)

Testing Cycles

Euro VI HD limit 8 x 1011 #/kWh (proposed for WHSC)

3022A at CVS (7 nm)

3790 under APC (23 nm)

3772 under CS (11 nm)

28