1 Lab Manual OPTEX-FA LASER DISPLACMENT SENSOR Laser Head CD4-L30 / Controller CD4A-LN / DBU-120A Prepared by Tran Ngoc Dang Khoa ElectroMechanical Energy Laboratory May 2016

Lab Manual - 中興大學教職員工網頁web.nchu.edu.tw/~daw/Manual/DisplacementsensorCD4_30.pdf1 Lab Manual OPTEX-FA LASER DISPLACMENT SENSOR Laser Head CD4-L30 / Controller CD4A-LN

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Lab Manual - 中興大學教職員工網頁web.nchu.edu.tw/~daw/Manual/DisplacementsensorCD4_30.pdf1 Lab Manual OPTEX-FA LASER DISPLACMENT SENSOR Laser Head CD4-L30 / Controller CD4A-LN

1

Lab Manual

OPTEX-FA

LASER DISPLACMENT SENSOR

Laser Head CD4-L30 / Controller CD4A-LN / DBU-120A

Prepared by

Tran Ngoc Dang Khoa

ElectroMechanical Energy Laboratory

May 2016

Page 2: Lab Manual - 中興大學教職員工網頁web.nchu.edu.tw/~daw/Manual/DisplacementsensorCD4_30.pdf1 Lab Manual OPTEX-FA LASER DISPLACMENT SENSOR Laser Head CD4-L30 / Controller CD4A-LN

2

Contents

1. Objectives ................................................................................. 3

2. Instruments ................................................................................ 3

3. System ....................................................................................... 4

4. Overview of DBU-120A .......................................................... 4

5. Procedure .................................................................................. 8

Page 3: Lab Manual - 中興大學教職員工網頁web.nchu.edu.tw/~daw/Manual/DisplacementsensorCD4_30.pdf1 Lab Manual OPTEX-FA LASER DISPLACMENT SENSOR Laser Head CD4-L30 / Controller CD4A-LN

3

1. Objectives

1.1 This manual describes steps to measure vibration using laser displacement

sensor.

1.2 Understand the control parameters of monitoring software LK-Navigator 2,

and learn the techniques to measure vibration even for transparent materials,

at ultrasonic speed, in different unit scales (mm, µm).

2. Instruments

2.1 Laser head CD4-L30

2.2 Power supply 12VDC

Page 4: Lab Manual - 中興大學教職員工網頁web.nchu.edu.tw/~daw/Manual/DisplacementsensorCD4_30.pdf1 Lab Manual OPTEX-FA LASER DISPLACMENT SENSOR Laser Head CD4-L30 / Controller CD4A-LN

4

2.3 Controller CD4A-LN

2.4 Data acquisition system DBU-120A

2.1 Monitor software Measurement

Page 5: Lab Manual - 中興大學教職員工網頁web.nchu.edu.tw/~daw/Manual/DisplacementsensorCD4_30.pdf1 Lab Manual OPTEX-FA LASER DISPLACMENT SENSOR Laser Head CD4-L30 / Controller CD4A-LN

5

3. System

Figure 1: System connection

2.1 Connect system follow figure 1.

Figure 2: DBU-120A connection

Page 6: Lab Manual - 中興大學教職員工網頁web.nchu.edu.tw/~daw/Manual/DisplacementsensorCD4_30.pdf1 Lab Manual OPTEX-FA LASER DISPLACMENT SENSOR Laser Head CD4-L30 / Controller CD4A-LN

6

Output: GND

Output: Voltage

Input from laser head

Input from

power supply

Figure 3: Controller connection

2.2 Measurement is monitored from the computer by Measurement

software.

4. Overview of LK-Navigator 2

4. Procedures

Measurement is a software for configuring parameters and monitoring the DBU-120A

controller. It is used by connecting a computer and the controller to configure parameters

and monitor operating status.

Procedure steps:

1. Setup the instruments as the Figure 1 on page 5.

2. Start Measurement on the computer

Page 7: Lab Manual - 中興大學教職員工網頁web.nchu.edu.tw/~daw/Manual/DisplacementsensorCD4_30.pdf1 Lab Manual OPTEX-FA LASER DISPLACMENT SENSOR Laser Head CD4-L30 / Controller CD4A-LN

7

3. On the interface, click on Setup button

Setup

Channel of

connected

device

Page 8: Lab Manual - 中興大學教職員工網頁web.nchu.edu.tw/~daw/Manual/DisplacementsensorCD4_30.pdf1 Lab Manual OPTEX-FA LASER DISPLACMENT SENSOR Laser Head CD4-L30 / Controller CD4A-LN

8

4. On the set DB condition tab, setup value of parameters:

5. Check all 3 checkboxes on the top left of Set DB condition. And click OK.

6. Click Monitor button to read the weight value from sensor.

In no-load condition, click Balance button to offset the weight to zero.

Page 9: Lab Manual - 中興大學教職員工網頁web.nchu.edu.tw/~daw/Manual/DisplacementsensorCD4_30.pdf1 Lab Manual OPTEX-FA LASER DISPLACMENT SENSOR Laser Head CD4-L30 / Controller CD4A-LN

9

7. Set recording data file: save data file with the file name, and starting number of the

extensions (for multiple data files).

Monitor Balance Double-click

to set upper,

lower limit Sampling

frequency

Number

of data

Page 10: Lab Manual - 中興大學教職員工網頁web.nchu.edu.tw/~daw/Manual/DisplacementsensorCD4_30.pdf1 Lab Manual OPTEX-FA LASER DISPLACMENT SENSOR Laser Head CD4-L30 / Controller CD4A-LN

10

8. An example of reading displacement value:

9. REMEMBER to safely remove DBU-120A device after using.