3
Date: Job Name/Location: PO No.: Architect: Engr: GC: Rep: For: File Approval Mech: Resubmit Other Tag #: (Company) (Project Manager) Performance: Capacity (MinRatedMax, Btu/h) SEER EER Cooling: Heating: Capacity (MinRatedMax, Btu/h) HSPF Cooling Nominal Test Conditions: Heating Nominal Test Conditions: Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WB Outdoor: 95°F DB/75°F WB Outdoor: 47°F DB/43°F WB Electrical: MCA (A) MOP (A) Compressor (A) Fan Motor (A) Outdoor Unit: Cooling Rated Amps (A) Heating Rated Amps (A) Cooling Power Input (kW) Heating Power Input (kW) Piping: Liquid Line (in, OD) Additional Refrigerant (oz/ft) Max Elevation (ft) Piping Length (no add'l refrigerant, ft) Features: •24Hour on/offƟmer •4Way auto swing •Auto changeover •Auto restart •Builtin low ambient operation to 14°F •Chaos wind •Self diagnosis Washable filter •SoŌ dry operaƟon Built-in base pan heater •Cooling only/heating only function Built-in Wi-Fi via Smart ThinQ app Page 1 of 3 For continual product development, LG reserves the right to change specifications without notice. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com Power Supply (V¹/Hz/Ø) Vapor Line (in, OD) Operating Range: Outdoor Unit: Cooling (°F DB) 14118 Heating (°F WB) 1365 Cooling (°F WB) 5375 Heating (°F DB) 6086 Indoor Unit: Unit Data: R410A Fan: Notes: 1.Acceptable operaƟng voltage: 187V 253V. 2.Piping lengths are equivalent. 3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 4.All power/communicaƟon cable to be minimum 14 AWG, 4conductor, stranded, shielded and must comply with applicable local and national code. 5.See Engineering Manual for sensible and latent capaciƟes. 6.Power wiring cable size must comply with the applicable local and naƟonal code. 7.The indoor unit comes with a dry helium charge. 8.This data is rated 0 Ō above sea level, with 24.6 Ō of refrigerant line and a 0 Ō level difference between outdoor and indoor units. 9.Must follow installaƟon instrucƟons in the applicable LG installaƟon manual. ODU Type Propeller IDU Type Cross Flow Motor/Drive Brushless Digitally Controlled/Direct EEV GoldFin™ Fan Speeds (Fan/Cooling/Heating) 6/6/6 Quantity (ODU + IDU) 1+1 ODU Max Air Flow Rate (CFM) IDU Air Flow Cooling, Max/H/M/L (CFM) IDU Air Flow Heating, Max/H/M/L (CFM) Dehumidification (pts/hr) Refrigerant Type Refrigerant Control Refrigerant Charge (lb) ODU Sound Pressure (Max, Cool/Heat1 dB(A)³ IDU Sound Pressure Cooling (H/M/L/Sleep) ±1 dB(A)³ IDU Sound Pressure Heating (H/M/L) ±1 dB(A)³ ODU Net Unit Weight (lbs) ODU Shipping Weight (lbs) IDU Net Unit Weight (lbs) IDU Shipping Weight (lbs) Heat Exchanger Coating Optional Accessories (sold separately): •Condensate sensor connection •Defrost control •Dehumidifying mode •Hot start •Jet cool/Jet heat •Self cleaning indoor coil SEER Seasonal Energy Efficiency Ratio EER Energy Efficiency Ratio HSPF Heating Seasonal Performance Factor MOP Maximum Overcurrent Protection MCA Minimum Circuit Ampacity Total Power Input: Min/Max Pipe Length (ft)²: For a complete list of available accessories, contact your LG representative. PI485 PMNFP14A1 LG Programmable Thermostat PREMTBVC0 Dry Contact - PDRYCB100/300/400 Low Ambient Wind Baffle (Cooling operation to 0°F) 208230/60/1 98.4 147.7 3,070 ~ 26,000 ~ 36,200 14.81 13.00 4.85 1.69 813 / 601 / 495 / 389 49/44/40 55/56 4.65 135.4 ZLABGP04A 30 19 0.38 12.5 0.4 49/44/40/30 24.6 22.5 2119 LA240HYV3 14.81 Outdoor Unit (ODU) - LAU240HYV3 Indoor Unit (IDU) - LAN240HYV3 3,070 ~ 22,000 ~ 30,000 45.6 37.7 2.08 14.41 9.8 / 164 3/8 5/8 919 / 707 / 601 / 495 SB_SZ_ArtCoolPremier_LA240HYV3_2020_03_17_090006 Art Cool™ Premier Single Zone Inverter

LA240HYV3 Art Cool Premier Single Zone Inverter

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LA240HYV3 Art Cool Premier Single Zone Inverter

Date:

Job Name/Location:

PO No.:

Architect:

Engr:

GC:

Rep:

For: File

Approval

Mech:

Resubmit

Other

Tag #:

(Company) (Project Manager)

Performance:

Capacity (Min‐Rated‐Max, Btu/h)

SEER

EER

Cooling:

Heating:

Capacity (Min‐Rated‐Max, Btu/h)

HSPF

Cooling Nominal Test Conditions: Heating Nominal Test Conditions:Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WB

Outdoor: 95°F DB/75°F WB Outdoor: 47°F DB/43°F WB

Electrical:

MCA (A)

MOP (A)

Compressor (A)

Fan Motor (A)

Outdoor Unit:

Cooling Rated Amps (A)

Heating Rated Amps (A)

Cooling Power Input (kW) Heating Power Input (kW)

Piping:

Liquid Line (in, OD)

Additional Refrigerant (oz/ft)

Max Elevation (ft)

Piping Length (no add'l refrigerant, ft)

Features: •24‐Hour on/off  mer •4‐Way auto swing •Auto changeover •Auto restart •Built‐in low ambient operation to 14°F •Chaos wind

•Self diagnosis•Washable filter•So  dry opera on•Built-in base pan heater•Cooling only/heating only function•Built-in Wi-Fi via Smart ThinQ app

Page 1 of 3

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

Power Supply (V¹/Hz/Ø)

Vapor Line (in, OD)

Operating Range:

Outdoor Unit:

Cooling (°F DB) 14‐118

Heating (°F WB) ‐13‐65

Cooling (°F WB) 53‐75

Heating (°F DB) 60‐86

Indoor Unit:

Unit Data:

R410A

Fan:

Notes:1.Acceptable opera ng voltage: 187V ‐ 253V.2.Piping lengths are equivalent.3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.4.All power/communica on cable to be minimum 14 AWG, 4‐conductor, stranded, shieldedand must comply with applicable local and national code.5.See Engineering Manual for sensible and latent capaci es.6.Power wiring cable size must comply with the applicable local and na onal code.7.The indoor unit comes with a dry helium charge.

8.This data is rated 0   above sea level, with 24.6   of refrigerant line and a 0   leveldifference between outdoor and indoor units.

9.Must follow installa on instruc ons in the applicable LG installa on manual.

ODU Type Propeller

IDU Type Cross Flow

Motor/Drive Brushless Digitally Controlled/Direct

EEV

GoldFin™

Fan Speeds (Fan/Cooling/Heating) 6/6/6

Quantity (ODU + IDU) 1 + 1

ODU Max Air Flow Rate (CFM)

IDU Air Flow Cooling, Max/H/M/L (CFM) IDU Air Flow Heating, Max/H/M/L (CFM) Dehumidification (pts/hr)

Refrigerant Type

Refrigerant Control

Refrigerant Charge (lb)ODU Sound Pressure (Max, Cool/Heat) ±1 dB(A)³ IDU Sound Pressure Cooling (H/M/L/Sleep) ±1 dB(A)³ IDU Sound Pressure Heating (H/M/L) ±1 dB(A)³ ODU  Net Unit Weight (lbs)

ODU Shipping Weight (lbs)

IDU Net Unit Weight (lbs)

IDU Shipping Weight (lbs)

Heat Exchanger Coating

Optional Accessories (sold separately):

•Condensate sensorconnection •Defrost control •Dehumidifying mode •Hot start •Jet cool/Jet heat •Self cleaning indoor coil

SEER ‐ Seasonal Energy Efficiency Ratio EER ‐ Energy Efficiency Ratio

HSPF ‐ Heating Seasonal Performance Factor

MOP ‐ Maximum Overcurrent Protection MCA ‐ Minimum Circuit Ampacity

Total Power Input:

Min/Max Pipe Length (ft)²:

For a complete list of available accessories, contact your LG representative.

PI‐485 ‐ PMNFP14A1

LG Programmable Thermostat ‐ PREMTBVC0Dry Contact - PDRYCB100/300/400Low Ambient Wind Baffle (Cooling operation to 0°F) ‐ 

208‐230/60/1

98.4

147.7

3,070 ~ 26,000 ~ 36,200

14.81

13.00

4.85

1.69

813 / 601 / 495 / 389

49/44/40

55/56

4.65

135.4

ZLABGP04A

3019

0.38

12.5

0.4

49/44/40/30

24.6

22.5

2119

LA240HYV3

14.81

Outdoor Unit (ODU) - LAU240HYV3 Indoor Unit (IDU) - LAN240HYV3

3,070 ~ 22,000 ~ 30,000

45.637.7

2.08

14.41

9.8 / 164

3/8

5/8919 / 707 / 601 / 495

SB_SZ_ArtCoolPremier_LA240HYV3_2020_03_17_090006

Art Cool™ Premier Single Zone Inverter

Page 2: LA240HYV3 Art Cool Premier Single Zone Inverter

Job Name/Location:

Tag #:

Date:

PO No.:

Page 2 of 3

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

LA240HYV3

Outdoor Unit (ODU) - LAU240HYV3 Indoor Unit (IDU) - LAN240HYV3

SB_SZ_ArtCoolPremier_LA240HYV3_2020_03_17_090006

Art Cool™ Premier Single Zone Inverter

Page 3: LA240HYV3 Art Cool Premier Single Zone Inverter

Job Name/Location:

Tag #:

Date:

PO No.:

Page 3 of 3

For continual product development, LG reserves the right to change specifications without notice.

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

LA240HYV3

Outdoor Unit (ODU) - LAU240HYV3 Indoor Unit (IDU) - LAN240HYV3

SB_SZ_ArtCoolPremier_LA240HYV3_2020_03_17_090006

Art Cool™ Premier Single Zone Inverter