8/11/2019 KYTC Bridge Inspections 2007-2013
1/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/16/13
Inspector: GCADY (213)
Primary Type: Joint Annual (12 Months)
District Review Date:
District Reviewer:Inspector Signature:
Sufficiency Ratings
SR: 59 SD/FO: 2 F
Vertical Clearances
Minimum Vertical Overclearance (53): 14.75 14.75
Minimum Vertical Underclearance (54): 0.00 0.00
Maximum Vertical Clearance (10): 18.33 99.99
Minimum Vertical Clearance: 0.00 99.99
DECK/WEARING SURFACE
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:91.6
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:
WATERWAY
Scour Critical (113): 8
Observed 113 Rating: U
Waterway Adeq. (71): 9
Load Rating and Posting
Truck Type Typ I Typ II Typ III Typ IV Gross
Recomm. Posting: 36 39 43 66
Field Posting: -1 -1 -1 -1 -1
Posting Status (41): A Open, no restriction
Signs Posted: Cardinal: N Non-Cardinal: N
SCHEDULE TAB
Schedule: Required (Y/N) Last Date Frequency Next Date
NBI (90): 9/16/13 (91): 24 mos 09/2015
Fracture Critical (92A): Y (93A): 12/29/10 (92A): 24 mos 11/9/14
Underwater (92B): Y (93B): 10/10/07 (92B): 60 mos 10/10/12
Other Special (92C): N (93C): 12/29/10 (92C): mos 10/15/09
Elemental: NA 24 mos 9/16/15
NBI CONDITION
Deck (58): 6
Superstructure (59): 6
Substructure (60): 6
Culverts (62): N
Channel/Protection (61): 7
District Number:
County (3):
Feature Intersected (6):
Road Name:
IDENTIFICATIONBridge ID (8): 059B00046N 059B00046N
Route Carried (7): I-75 I-75
Mile Point: 191.533 191.536
Location (9): BRENT SPENCE BR OVER OHIO BRENT SPENCE BR OVER OHIO
Structure Description:1736.5 Foot - 3 Span Steel continuous
Truss - Thru
1736.5 Foot - 3 Span Steel continuous
Truss - Thru
11/1/13
BSEITER (55)
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
2/68
tionally Obsolete
6 6
59 Kenton 59 Kenton
OHIO RIVER OHIO RIVER
I-75 I-75 NC
8/11/2019 KYTC Bridge Inspections 2007-2013
3/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/16/13
Inspector: GCADY (213)
Primary Type: Joint Annual (12 Months)
Element Condition State Data
Str UnitElm/Env Description Description
1 102/1 Paint StlBox Girder
Riveted built-up box girder floorbeams exist at UD PP 17 and 17'. The box girder floor beams exhibit
moderate surface rust and section loss of top flange and rivet heads, 10% and 25% respectively. There is
debris from open joint on the top flange of the floorbeam.
1 113/1 Paint StlStringer
The paint has failed and is flaking on the interior upper deck stringers. In locations of expansion joints the
stringers have moderate surface rust with minimal section loss. At some of the splices along the exterior
stringers, pack rust is forming along the edge of the bottom flange splice plate.
1 121/1 P/Stl ThruTruss/Bot
There is pack rust occurring at the lower chord, particularly on the splice plates, filler plates, and cover
plates. There is also pack rust along the edges of the lower chord. This pack rust is causing the edge of
the plate to curl-up. Minor to moderate section loss is occurring on the underside of the lower chord,
particularly in the area of the cover plates and splice plates.
The inboard and outboard gusset plates at the lower chord panel points are generally in good condition.
There is surface rust and flaking paint on the gusset plates, and pack rust around the edges of the plates.
See appendix of short form for table of condition states for each gusset plate.
Element Condition State Data
Elm/Env Description Units Total QTY QTY CS1 QTY CS2 QTY CS3 QTY CS4 QTY CS5
102/1 Paint Stl Box Girder LF 102.00 0.00 51.00 51.00 0.00 0.00
113/1 Paint Stl Stringer LF 27784.00 13792.00 5556.80 8335.20 100.00 0.00
121/1 P/Stl Thru Truss/Bot LF 3473.00 0.00 2778.40 694.60 0.00 0.00
126/1 P/Stl Thru Truss/Top LF 3473.00 0.00 3125.70 347.30 0.00 0.00
152/1 Paint Stl Floor Beam LF 4763.00 1190.75 2143.35 1428.90 0.00 0.00
205/1 R/Conc Column EA 4.00 3.00 1.00 0.00 0.00 0.00
210/1 R/Conc Pier Wall LF 148.00 133.20 14.80 0.00 0.00 0.00
22/1 P Conc Deck/Rigid Ov SF 159035.00 0.00 159035.00 0.00 0.00 0.00
301/1 Pourable Joint Seal LF 1237.00 618.50 618.50 0.00 0.00 0.00
303/1 Assembly Joint/Seal LF 367.00 0.00 367.00 0.00 0.00 0.00
311/1 Moveable Bearing EA 164.00 154.00 10.00 0.00 0.00 0.00
313/1 Fixed Bearing EA 4.00 4.00 0.00 0.00 0.00 0.00
331/1 Conc Bridge Railing LF 6946.00 6876.54 0.00 69.46 0.00 0.00
356/1 Steel Fatigue SmFlag EA 1.00 0.00 1.00 0.00 0.00 0.00
357/1 Pack Rust Smart Flag EA 1.00 0.00 1.00 0.00 0.00 0.00
359/1 Soffit Smart Flag EA 1.00 0.00 1.00 0.00 0.00 0.00
604/1 2nd Elem Dist EA 1.00 0.00 1.00 0.00 0.00 0.00
606/1 Drains EA 1.00 0.00 0.00 1.00 0.00 0.00
609/1 Debris on Superstruc EA 1.00 0.00 1.00 0.00 0.00 0.00
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
4/68
8/11/2019 KYTC Bridge Inspections 2007-2013
5/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/16/13
Inspector: GCADY (213)
Primary Type: Joint Annual (12 Months)
Element Condition State Data
Str UnitElm/Env Description Description
1 126/1 P/Stl ThruTruss/Top
The top chord members and the gussets plate connections to the verticals, diagonals, and lateral bracing
are generally in good condition. The minor deterioration occasionally observed includes (1) surface rust
and minor pack rust along the edge of gusset plates, (2) minor debris and surface rust inside of the topchord around the connection bolts for the top chord splices, (3) pack rust along the outside and inside
edges of the top chord member, and (4) pack rust along the edges of the keeper plates.
The truss members (including the vertical and diagonal members) typically have minor surface rust along
the inside and outside corners of the boxes. Also, along the edge of the internal diaphragms, the truss
members have minor to moderate surface rust, pitting, and pack rust. The corrosion is active in some
areas, but the section loss in the primary members is typically between 1/16 and 3/16. There is pack rust
noted up to 3/16 on the inside of the verticals, especially around the interior diaphragms. There is a
2x0.75 hole in member L1-U1 upstream with a 3.5 diameter area around the hole going from 100%
section loss to 0% of the 0.5 plate.
See appendix of short form for table of condition states for each gusset plate of the top chord and mid-
height joints.
1 152/1 Paint Stl
Floor Beam
The floor beams were observed in overall fair condition. The primary deficiencies noted were cracks at
the floor beam connection to the truss. Of the fourteen total locations, two locations were observed at theend of the floor beam top flange angle at the connection to the truss, eleven locations were noted at the
end of the floor beam in the T-connection at the connection to the truss and one 5/8 crack originating at
rivet hole to edge of fill plate of FB16, UD, DS (see Appendix for table).
1 205/1 R/ConcColumn
Overall, the piers are in satisfactory condition. Minor cracks with minor spalls were observed for Piers I,
II, and III. Pier IV exhibits heavy map cracking and delamination along bottom of pier cap and the full
height of the upstream column, west face.
1 210/1 R/Conc Pier Wall
Minor cracking was present at the bearing areas.
1 22/1 P ConcDeck/RigidOv
The deck was noted in overall satisfactory condition and appears to be structurally sound. The bottom of
the lower deck has spalling with exposed rebar adjacent at the majority of the deck joints. The bottom of
the upper deck exhibited cracking with efflorescence adjacent to the deck joints at a few locations. The
wearing surface of the upper and lower decks are in fair condition with minor spalling typically adjacent to
the expansion joints along with transverse and longitudinal cracking throughout. Grooving in the wearingsurface is showing wear in the wheel path.
1 301/1 PourableJoint Seal
The upper deck joints have been repaired since the previous inspection and are in overall satisfactory
condition. Lower deck joints are in overall poor condition. Primary deficiencies to lower deck joints occur
on bottom of the deck (see 58.1) and leakage.
1 303/1 AssemblyJoint/Seal
Some of the expansion joints at the ends of the truss show a small amount of vertical misalignment. It is
noted up to 1/2. The troughs under these joints are all filled or overflowing with debris.
1 311/1 MoveableBearing
The bearings show fair amounts of surface and pack rust throughout the truss, and heavy pack rust and
active corrosion under the expansion joints. The bearings at the piers are in good condition.
1 313/1 FixedBearing
1 331/1 Conc Bridge
Railing
Vertical cracks in the concrete barriers are typical throughout the length of the bridge. The barrier have
isolated areas of spalling.
1 356/1 SteelFatigueSmFlag
There are cracks on the T-connections, filler plates, and welds of the floorbeams. See appendix for crack
sizes and locations.
1 357/1 Pack RustSmart Flag
There is pack rust occurring at the lower chord, particularly on the splice plates, filler plates, and cover
plates. There is also pack rust along the edges of the lower chord. There is active pack rust between the
gusset plates and the vertical faces of the lower chord.
1 359/1 Soffit SmartFlag
There is spalled concrete around the joints on the bottom of the deck with exposed rebar.
1 604/1 2nd ElemDist
As previously noted, fractured bolts and guide plates where present at U17-U18 and U17'-U18' members
at panel point 17 and 17', respectively.
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
6/68
8/11/2019 KYTC Bridge Inspections 2007-2013
7/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/16/13
Inspector: GCADY (213)
Primary Type: Joint Annual (12 Months)
Work Candidates
Inspector Candidates: Agency Status Deta
Candidate ID: Status Priority Assigned Action Elem Date Recommended
059-B00046N-1 Approved High Unassigned 60 0 9/16/13
Element Condition State Data
Str UnitElm/Env Description Description
1 606/1 Drains The deck drains are completely clogged with debris and vegetation. The downspouts are heavilycorroded, to the point of 100% section loss in some locations. The neoprene boots on the downspouts
are worn and cracked.
1 609/1 Debris onSuperstruc
There is moderate debris on top of the floorbeams at locations of expansion joints. Also there is moderate
debris on the cat walk at FB17 and FB17'. The lower chord and diagonal members were cleaned during a
2010 maintenance cleaning project.
KYTC Bridge Inspection Report059B00046N
Structure Notes
*NOTE THAT THIS 2013 JOINT ANNUAL INSPECTION IN CONJUNCTION WITH ODOT WAS PERFORMED ON 09/16/2013.Joint annual inspection notes are as followed:-All needed repairs throughout structure were left in place for detail in the Inspection Notes Tab from last Fracture CriticalInspection dated 12/29/2010 (Entran, PLC).-Structure is in need of varying degrees of rehab construction soon (paint protective coating system, deck surface patching and/or total overlay project, expansion joint device repairs, under deck inspection walk repairs, etc.).
-Deck surface is deteriorating along intermediate expansion joint device locations. Full depth holes/failures are starting to occur/develop in upper deck of structure at two locations near the north end of bridge as evident from view below. Area of deck alongexpansion joint at panel point #7 of the lower deck was found to have an area of full depth failure that was found during JAInspection, which was repaired same by state crew forces.-Under deck inspection walk system as well as the northbound lower most deck was accessed during time of Joint Annual withODOT. Clip angle connections supporting under deck inspection walk system at back side location of floorbeam element #16remains fractured at this time and are no longer operating as designed.-Protective paint coating system throughout structure was found showing failure, with worst locations being located along areasof expansion joint devices as well as structural members near traveled lanes of structure.-Broken light pole KY span.
This inspection was limited to the "Joint Annual Inspection" with ODOT personnel accessing deck area throughout the lowernorthbound lanes and under deck inspection walk system through portion of structure and does not include Element Level or NBIRated portions for structure. This inspection was not a thorough inspection review of structure.For full detailed inspection report of structure see inspection report dated 12/29/2010.
Inspection Notes
ENTRAN,PLC on December 29, 2010 completed a fracture critical inspection of the truss bridge. The inspection included datagathering for both NBI and PONTIS element level inspection reporting.
In summary, the Brent Spence Bridge is considered to be in overall fair condition. The following NBI condition ratings wereassigned to the structure: DECK - 6; SUPERSTRUCTURE - 6; PAINT CONDITION - 5; SUBSTRUCTURE - 7
ENTRAN suggests the following maintenance recommendations: repair new and active cracks, replace the bolts and fracturedguide plates of the sliding pins at the upper chord, replace compression seals and repair damaged armored edges, remove rustfrom bearings at expansion joints, clean drains and drain pipes, clean troughs under expansion joints, replace the broken ormissing utility box covers, monitor pack rust and section loss thrhoughout truss, clean and paint the floorbeams and stringers,and repair spalls in deck and barriers.
See the signed 2010 Short Form Report on file for description of the Scope of Work, detailed summary of deficiencies and TC71-118 Bridge Inspection Report.
8/11/2019 KYTC Bridge Inspections 2007-2013
8/68
8/11/2019 KYTC Bridge Inspections 2007-2013
9/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: Y
Underwater: N
Other Special: N
Summary:
Inspection Date: 11/9/12
Inspector: MBARON (89)
Primary Type: FracCrit (24 Months)
District Review Date:
District Reviewer:Inspector Signature:
Sufficiency Ratings
SR: 59 SD/FO: 2 F
Vertical Clearances
Minimum Vertical Overclearance (53): 14.75 14.75
Minimum Vertical Underclearance (54): 0.00 0.00
DECK/WEARING SURFACE
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:91.6
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:
WATERWAY
Scour Critical (113): 8
Observed 113 Rating: U
Waterway Adeq. (71): 9
Load Rating and Posting
Truck Type Typ I Typ II Typ III Typ IV Gross
Recomm. Posting: 36 39 43 66
Field Posting: -1 -1 -1 -1 -1
Posting Status (41): A Open, no restriction
Signs Posted: Cardinal: N Non-Cardinal: N
SCHEDULE TAB
Schedule: Required (Y/N) Last Date Frequency Next Date
NBI (90): 11/9/12 (91): 24 mos 11/2014
Fracture Critical (92A): Y (93A): 12/29/10 (92A): 24 mos 11/9/14
Underwater (92B): Y (93B): 10/10/07 (92B): 60 mos 10/10/12
Other Special (92C): N (93C): 12/29/10 (92C): mos 10/15/09
Elemental: NA 24 mos 11/9/14
NBI CONDITION
Deck (58): 6
Superstructure (59): 6
Substructure (60): 6
Culverts (62): N
Channel/Protection (61): 7
District Number:
County (3):
Feature Intersected (6):
Road Name:
IDENTIFICATION
Bridge ID (8): 059B00046N 059B00046N
Route Carried (7): I-75 I-75
Mile Point: 191.533 191.536
Location (9): BRENT SPENCE BR OVER OHIO BRENT SPENCE BR OVER OHIO
Structure Description:1736.5 Foot - 3 Span Steel continuous
Truss - Thru
1736.5 Foot - 3 Span Steel continuous
Truss - Thru
12/11/12
BSEITER (55)
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
10/68
tionally Obsolete
6 6
59 Kenton 59 Kenton
OHIO RIVER OHIO RIVER
I-75 I-75 NC
8/11/2019 KYTC Bridge Inspections 2007-2013
11/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: Y
Underwater: N
Other Special: N
Summary:
Inspection Date: 11/9/12
Inspector: MBARON (89)
Primary Type: FracCrit (24 Months)
Element Condition State Data
Str UnitElm/Env Description Description
1 102/1 Paint StlBox Girder
Riveted built-up box girder floorbeams exist at UD PP 17 and 17'. The box girder floor beams exhibit
moderate surface rust and section loss of top flange and rivet heads, 10% and 25% respectively. There is
debris from open joint on the top flange of the floorbeam.
1 113/1 Paint StlStringer
The paint has failed and is flaking on the interior upper deck stringers. In locations of expansion joints thestringers have moderate surface rust with minimal section loss. At some of the splices along the exterior
stringers, pack rust is forming along the edge of the bottom flange splice plate.
1 121/1 P/Stl ThruTruss/Bot
There is pack rust occurring at the lower chord, particularly on the splice plates, filler plates, and cover
plates. There is also pack rust along the edges of the lower chord. This pack rust is causing the edge of
the plate to curl-up. Minor to moderate section loss is occurring on the underside of the lower chord,
particularly in the area of the cover plates and splice plates.
The inboard and outboard gusset plates at the lower chord panel points are generally in good condition.
There is surface rust and flaking paint on the gusset plates, and pack rust around the edges of the plates.
See appendix of short form for table of condition states for each gusset plate.
Element Condition State Data
Elm/Env Description Units Total QTY QTY CS1 QTY CS2 QTY CS3 QTY CS4 QTY CS5
102/1 Paint Stl Box Girder LF 102.00 0.00 51.00 51.00 0.00 0.00
113/1 Paint Stl Stringer LF 27784.00 13792.00 5556.80 8335.20 100.00 0.00
121/1 P/Stl Thru Truss/Bot LF 3473.00 0.00 2778.40 694.60 0.00 0.00
126/1 P/Stl Thru Truss/Top LF 3473.00 0.00 3125.70 347.30 0.00 0.00
152/1 Paint Stl Floor Beam LF 4763.00 1190.75 2143.35 1428.90 0.00 0.00
205/1 R/Conc Column EA 4.00 3.00 1.00 0.00 0.00 0.00
210/1 R/Conc Pier Wall LF 148.00 133.20 14.80 0.00 0.00 0.00
22/1 P Conc Deck/Rigid Ov SF 159035.00 0.00 159035.00 0.00 0.00 0.00
301/1 Pourable Joint Seal LF 1237.00 618.50 618.50 0.00 0.00 0.00
303/1 Assembly Joint/Seal LF 367.00 0.00 367.00 0.00 0.00 0.00
311/1 Moveable Bearing EA 164.00 154.00 10.00 0.00 0.00 0.00
313/1 Fixed Bearing EA 4.00 4.00 0.00 0.00 0.00 0.00
331/1 Conc Bridge Railing LF 6946.00 6876.54 0.00 69.46 0.00 0.00
356/1 Steel Fatigue SmFlag EA 1.00 0.00 1.00 0.00 0.00 0.00
357/1 Pack Rust Smart Flag EA 1.00 0.00 1.00 0.00 0.00 0.00
359/1 Soffit Smart Flag EA 1.00 0.00 1.00 0.00 0.00 0.00
604/1 2nd Elem Dist EA 1.00 0.00 1.00 0.00 0.00 0.00
606/1 Drains EA 1.00 0.00 0.00 1.00 0.00 0.00
609/1 Debris on Superstruc EA 1.00 0.00 1.00 0.00 0.00 0.00
Maximum Vertical Clearance (10): 18.33 99.99
Minimum Vertical Clearance: 0.00 99.99
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
12/68
8/11/2019 KYTC Bridge Inspections 2007-2013
13/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: Y
Underwater: N
Other Special: N
Summary:
Inspection Date: 11/9/12
Inspector: MBARON (89)
Primary Type: FracCrit (24 Months)
Element Condition State Data
Str UnitElm/Env Description Description
1 126/1 P/Stl ThruTruss/Top
The top chord members and the gussets plate connections to the verticals, diagonals, and lateral bracing
are generally in good condition. The minor deterioration occasionally observed includes (1) surface rust
and minor pack rust along the edge of gusset plates, (2) minor debris and surface rust inside of the topchord around the connection bolts for the top chord splices, (3) pack rust along the outside and inside
edges of the top chord member, and (4) pack rust along the edges of the keeper plates.
The truss members (including the vertical and diagonal members) typically have minor surface rust along
the inside and outside corners of the boxes. Also, along the edge of the internal diaphragms, the truss
members have minor to moderate surface rust, pitting, and pack rust. The corrosion is active in some
areas, but the section loss in the primary members is typically between 1/16 and 3/16. There is pack rust
noted up to 3/16 on the inside of the verticals, especially around the interior diaphragms. There is a
2x0.75 hole in member L1-U1 upstream with a 3.5 diameter area around the hole going from 100%
section loss to 0% of the 0.5 plate.
See appendix of short form for table of condition states for each gusset plate of the top chord and mid-
height joints.
1 152/1 Paint Stl
Floor Beam
The floor beams were observed in overall fair condition. The primary deficiencies noted were cracks at
the floor beam connection to the truss. Of the fourteen total locations, two locations were observed at theend of the floor beam top flange angle at the connection to the truss, eleven locations were noted at the
end of the floor beam in the T-connection at the connection to the truss and one 5/8 crack originating at
rivet hole to edge of fill plate of FB16, UD, DS (see Appendix for table).
1 205/1 R/ConcColumn
Overall, the piers are in satisfactory condition. Minor cracks with minor spalls were observed for Piers I,
II, and III. Pier IV exhibits heavy map cracking and delamination along bottom of pier cap and the full
height of the upstream column, west face.
1 210/1 R/Conc Pier Wall
Minor cracking was present at the bearing areas.
1 22/1 P ConcDeck/RigidOv
The deck was noted in overall satisfactory condition and appears to be structurally sound. The bottom of
the lower deck has spalling with exposed rebar adjacent at the majority of the deck joints. The bottom of
the upper deck exhibited cracking with efflorescence adjacent to the deck joints at a few locations. The
wearing surface of the upper and lower decks are in fair condition with minor spalling typically adjacent to
the expansion joints along with transverse and longitudinal cracking throughout. Grooving in the wearingsurface is showing wear in the wheel path.
1 301/1 PourableJoint Seal
The upper deck joints have been repaired since the previous inspection and are in overall satisfactory
condition. Lower deck joints are in overall poor condition. Primary deficiencies to lower deck joints occur
on bottom of the deck (see 58.1) and leakage.
1 303/1 AssemblyJoint/Seal
Some of the expansion joints at the ends of the truss show a small amount of vertical misalignment. It is
noted up to 1/2. The troughs under these joints are all filled or overflowing with debris.
1 311/1 MoveableBearing
The bearings show fair amounts of surface and pack rust throughout the truss, and heavy pack rust and
active corrosion under the expansion joints. The bearings at the piers are in good condition.
1 313/1 FixedBearing
1 331/1 Conc Bridge
Railing
Vertical cracks in the concrete barriers are typical throughout the length of the bridge. The barrier have
isolated areas of spalling.
1 356/1 SteelFatigueSmFlag
There are cracks on the T-connections, filler plates, and welds of the floorbeams. See appendix for crack
sizes and locations.
1 357/1 Pack RustSmart Flag
There is pack rust occurring at the lower chord, particularly on the splice plates, filler plates, and cover
plates. There is also pack rust along the edges of the lower chord. There is active pack rust between the
gusset plates and the vertical faces of the lower chord.
1 359/1 Soffit SmartFlag
There is spalled concrete around the joints on the bottom of the deck with exposed rebar.
1 604/1 2nd ElemDist
As previously noted, fractured bolts and guide plates where present at U17-U18 and U17'-U18' members
at panel point 17 and 17', respectively.
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
14/68
8/11/2019 KYTC Bridge Inspections 2007-2013
15/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: Y
Underwater: N
Other Special: N
Summary:
Inspection Date: 11/9/12
Inspector: MBARON (89)
Primary Type: FracCrit (24 Months)
Work Candidates
Inspector Candidates: Agency Status Deta
Candidate ID: Status Priority Assigned Action Elem Date Recommended
059-B00046N-1 Approved High Unassigned 60 0 9/16/13
Element Condition State Data
Str UnitElm/Env Description Description
1 606/1 Drains The deck drains are completely clogged with debris and vegetation. The downspouts are heavilycorroded, to the point of 100% section loss in some locations. The neoprene boots on the downspouts
are worn and cracked.
1 609/1 Debris onSuperstruc
There is moderate debris on top of the floorbeams at locations of expansion joints. Also there is moderate
debris on the cat walk at FB17 and FB17'. The lower chord and diagonal members were cleaned during a
2010 maintenance cleaning project.
KYTC Bridge Inspection Report059B00046N
Structure Notes
*NOTE THAT THIS 2013 JOINT ANNUAL INSPECTION IN CONJUNCTION WITH ODOT WAS PERFORMED ON 09/16/2013.Joint annual inspection notes are as followed:-All needed repairs throughout structure were left in place for detail in the Inspection Notes Tab from last Fracture CriticalInspection dated 12/29/2010 (Entran, PLC).-Structure is in need of varying degrees of rehab construction soon (paint protective coating system, deck surface patching and/or total overlay project, expansion joint device repairs, under deck inspection walk repairs, etc.).
-Deck surface is deteriorating along intermediate expansion joint device locations. Full depth holes/failures are starting to occur/develop in upper deck of structure at two locations near the north end of bridge as evident from view below. Area of deck alongexpansion joint at panel point #7 of the lower deck was found to have an area of full depth failure that was found during JAInspection, which was repaired same by state crew forces.-Under deck inspection walk system as well as the northbound lower most deck was accessed during time of Joint Annual withODOT. Clip angle connections supporting under deck inspection walk system at back side location of floorbeam element #16remains fractured at this time and are no longer operating as designed.-Protective paint coating system throughout structure was found showing failure, with worst locations being located along areasof expansion joint devices as well as structural members near traveled lanes of structure.-Broken light pole KY span.
This inspection was limited to the "Joint Annual Inspection" with ODOT personnel accessing deck area throughout the lowernorthbound lanes and under deck inspection walk system through portion of structure and does not include Element Level or NBIRated portions for structure. This inspection was not a thorough inspection review of structure.For full detailed inspection report of structure see inspection report dated 12/29/2010.
Inspection Notes
ENTRAN,PLC on December 29, 2010 completed a fracture critical inspection of the truss bridge. The inspection included datagathering for both NBI and PONTIS element level inspection reporting.
In summary, the Brent Spence Bridge is considered to be in overall fair condition. The following NBI condition ratings wereassigned to the structure: DECK - 6; SUPERSTRUCTURE - 6; PAINT CONDITION - 5; SUBSTRUCTURE - 7
ENTRAN suggests the following maintenance recommendations: repair new and active cracks, replace the bolts and fracturedguide plates of the sliding pins at the upper chord, replace compression seals and repair damaged armored edges, remove rustfrom bearings at expansion joints, clean drains and drain pipes, clean troughs under expansion joints, replace the broken ormissing utility box covers, monitor pack rust and section loss thrhoughout truss, clean and paint the floorbeams and stringers,and repair spalls in deck and barriers.
See the signed 2010 Short Form Report on file for description of the Scope of Work, detailed summary of deficiencies and TC71-118 Bridge Inspection Report.
8/11/2019 KYTC Bridge Inspections 2007-2013
16/68
8/11/2019 KYTC Bridge Inspections 2007-2013
17/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: N
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/10/12
Inspector: GCOCHRAN (23)
Primary Type: Joint Annual (12 Months)
District Review Date:
District Reviewer:Inspector Signature:
Sufficiency Ratings
SR: 59 SD/FO: 2 F
Vertical Clearances
Minimum Vertical Overclearance (53): 14.75 14.75
Minimum Vertical Underclearance (54): 0.00 0.00
DECK/WEARING SURFACE
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:91.6
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:
WATERWAY
Scour Critical (113): 8
Observed 113 Rating: U
Waterway Adeq. (71): 9
Load Rating and Posting
Truck Type Typ I Typ II Typ III Typ IV Gross
Recomm. Posting: 36 39 43 66
Field Posting: -1 -1 -1 -1 -1
Posting Status (41): A Open, no restriction
Signs Posted: Cardinal: N Non-Cardinal: N
SCHEDULE TAB
Schedule: Required (Y/N) Last Date Frequency Next Date
NBI (90): 9/10/12 (91): 24 mos 09/2014
Fracture Critical (92A): Y (93A): 12/29/10 (92A): 24 mos 12/29/12
Underwater (92B): Y (93B): 10/10/07 (92B): 60 mos 10/10/12
Other Special (92C): N (93C): 12/29/10 (92C): mos 10/15/09
Elemental: NA 24 mos 12/29/12
NBI CONDITION
Deck (58): 6
Superstructure (59): 6
Substructure (60): 7
Culverts (62): N
Channel/Protection (61): 7
District Number:
County (3):
Feature Intersected (6):
Road Name:
IDENTIFICATION
Bridge ID (8): 059B00046N 059B00046N
Route Carried (7): I-75 I-75
Mile Point: 191.533 191.536
Location (9): BRENT SPENCE BR OVER OHIO BRENT SPENCE BR OVER OHIO
Structure Description:1736.5 Foot - 3 Span Steel continuous
Truss - Thru
1736.5 Foot - 3 Span Steel continuous
Truss - Thru
11/19/12
BSEITER (55)
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
18/68
tionally Obsolete
6 6
59 Kenton 59 Kenton
OHIO RIVER OHIO RIVER
I-75 I-75 NC
8/11/2019 KYTC Bridge Inspections 2007-2013
19/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: N
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/10/12
Inspector: GCOCHRAN (23)
Primary Type: Joint Annual (12 Months)
Work Candidates
Inspector Candidates: Agency Status Deta
Candidate ID: Status Priority Assigned Action Elem Date Recommended
Element Condition State Data
Str UnitElm/Env Description Description
/
Element Condition State Data
Elm/Env Description Units Total QTY QTY CS1 QTY CS2 QTY CS3 QTY CS4 QTY CS5
/ RROR 0.00 0.00 0.00 0.00 0.00 0.00
Maximum Vertical Clearance (10): 18.33 99.99
Minimum Vertical Clearance: 0.00 99.99
KYTC Bridge Inspection Report059B00046N
Structure Notes
*NOTE THAT THIS 2013 JOINT ANNUAL INSPECTION IN CONJUNCTION WITH ODOT WAS PERFORMED ON 09/16/2013.
Joint annual inspection notes are as followed:-All needed repairs throughout structure were left in place for detail in the Inspection Notes Tab from last Fracture CriticalInspection dated 12/29/2010 (Entran, PLC).-Structure is in need of varying degrees of rehab construction soon (paint protective coating system, deck surface patching and/or total overlay project, expansion joint device repairs, under deck inspection walk repairs, etc.).-Deck surface is deteriorating along intermediate expansion joint device locations. Full depth holes/failures are starting to occur/develop in upper deck of structure at two locations near the north end of bridge as evident from view below. Area of deck alongexpansion joint at panel point #7 of the lower deck was found to have an area of full depth failure that was found during JAInspection, which was repaired same by state crew forces.-Under deck inspection walk system as well as the northbound lower most deck was accessed during time of Joint Annual withODOT. Clip angle connections supporting under deck inspection walk system at back side location of floorbeam element #16remains fractured at this time and are no longer operating as designed.-Protective paint coating system throughout structure was found showing failure, with worst locations being located along areasof expansion joint devices as well as structural members near traveled lanes of structure.-Broken light pole KY span.
This inspection was limited to the "Joint Annual Inspection" with ODOT personnel accessing deck area throughout the lowernorthbound lanes and under deck inspection walk system through portion of structure and does not include Element Level or NBIRated portions for structure. This inspection was not a thorough inspection review of structure.For full detailed inspection report of structure see inspection report dated 12/29/2010.
Inspection Notes
ENTRAN,PLC on December 29, 2010 completed a fracture critical inspection of the truss bridge. The inspection included datagathering for both NBI and PONTIS element level inspection reporting.
In summary, the Brent Spence Bridge is considered to be in overall fair condition. The following NBI condition ratings wereassigned to the structure: DECK - 6; SUPERSTRUCTURE - 6; PAINT CONDITION - 5; SUBSTRUCTURE - 7
ENTRAN suggests the following maintenance recommendations: repair new and active cracks, replace the bolts and fracturedguide plates of the sliding pins at the upper chord, replace compression seals and repair damaged armored edges, remove rustfrom bearings at expansion joints, clean drains and drain pipes, clean troughs under expansion joints, replace the broken ormissing utility box covers, monitor pack rust and section loss thrhoughout truss, clean and paint the floorbeams and stringers,and repair spalls in deck and barriers.
See the signed 2010 Short Form Report on file for description of the Scope of Work, detailed summary of deficiencies and TC71-118 Bridge Inspection Report.
8/11/2019 KYTC Bridge Inspections 2007-2013
20/68
8/11/2019 KYTC Bridge Inspections 2007-2013
21/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: N
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/10/12
Inspector: GCOCHRAN (23)
Primary Type: Joint Annual (12 Months)
Work Candidates
Inspector Candidates: Agency Status Deta
Candidate ID: Status Priority Assigned Action Elem Date Recommended
059-B00046N-1 Approved High Unassigned 60 0 9/16/13
KYTC Bridge Inspection Report059B00046N
Types of Inspections Performed:
National Bridge Inventory: N
Element: N
Fracture Cr itical: NUnderwater: Y
Other Special: N
Summary:
Inspection Date: 8/30/12
Inspector: JJOHNSON (209)
Primary Type: UnWater (60 Months)
District Review Date:
District Reviewer:Inspector Signature:
DECK/WEARING SURFACE
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
WATERWAYScour Critical (113): 8
Observed 113 Rating: 8
Waterway Adeq. (71): 9
Load Rating and PostingTruck Type Typ I Typ II Typ III Typ IV Gross
Recomm. Posting: 36 39 43 66
Field Posting: -1 -1 -1 -1 -1
Posting Status (41): A Open, no restriction
Signs Posted: Cardinal: N Non-Cardinal: N
SCHEDULE TAB
Schedule: Required (Y/N) Last Date Frequency Next Date
NBI (90): 8/30/12 (91): 24 mos 09/2014
Fracture Critical (92A): Y (93A): 12/29/10 (92A): 24 mos 12/29/12
Underwater (92B): Y (93B): 10/10/07 (92B): 60 mos 8/30/17
Other Special (92C): N (93C): 12/29/10 (92C): mos 10/15/09
Elemental: NA 24 mos 12/29/12
NBI CONDITION
Deck (58): 6
Superstructure (59): 6
Substructure (60): 7
Culverts (62): N
Channel/Protection (61): 7
District Number:
County (3):
Feature Intersected (6):
Road Name:
IDENTIFICATION
Bridge ID (8): 059B00046N 059B00046N
Route Carried (7): I-75 I-75
Mile Point: 191.533 191.536
Location (9): BRENT SPENCE BR OVER OHIO BRENT SPENCE BR OVER OHIO
Structure Description:1736.5 Foot - 3 Span Steel continuous
Truss - Thru
1736.5 Foot - 3 Span Steel continuous
Truss - Thru
12/11/12
BSEITER (55)
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
22/68
6 6
59 Kenton 59 Kenton
OHIO RIVER OHIO RIVER
I-75 I-75 NC
8/11/2019 KYTC Bridge Inspections 2007-2013
23/68
Types of Inspections Performed:
National Bridge Inventory: N
Element: N
Fracture Cr itical: N
Underwater: Y
Other Special: N
Summary:
Inspection Date: 8/30/12
Inspector: JJOHNSON (209)
Primary Type: UnWater (60 Months)
Element Condition State Data
Str UnitElm/Env Description Description
/
Element Condition State Data
Elm/Env Description Units Total QTY QTY CS1 QTY CS2 QTY CS3 QTY CS4 QTY CS5
/ RROR 0.00 0.00 0.00 0.00 0.00 0.00
Sufficiency Ratings
SR: 59 SD/FO: 2 F
Vertical Clearances
Minimum Vertical Overclearance (53): 14.75 14.75
Minimum Vertical Underclearance (54): 0.00 0.00
Maximum Vertical Clearance (10): 18.33 99.99
Minimum Vertical Clearance: 0.00 99.99
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:91.6Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:
KYTC Bridge Inspection Report059B00046N
Structure Notes
*NOTE THAT THIS 2013 JOINT ANNUAL INSPECTION IN CONJUNCTION WITH ODOT WAS PERFORMED ON 09/16/2013.Joint annual inspection notes are as followed:-All needed repairs throughout structure were left in place for detail in the Inspection Notes Tab from last Fracture CriticalInspection dated 12/29/2010 (Entran, PLC).-Structure is in need of varying degrees of rehab construction soon (paint protective coating system, deck surface patching and/or total overlay project, expansion joint device repairs, under deck inspection walk repairs, etc.).-Deck surface is deteriorating along intermediate expansion joint device locations. Full depth holes/failures are starting to occur/develop in upper deck of structure at two locations near the north end of bridge as evident from view below. Area of deck alongexpansion joint at panel point #7 of the lower deck was found to have an area of full depth failure that was found during JAInspection, which was repaired same by state crew forces.
-Under deck inspection walk system as well as the northbound lower most deck was accessed during time of Joint Annual withODOT. Clip angle connections supporting under deck inspection walk system at back side location of floorbeam element #16remains fractured at this time and are no longer operating as designed.-Protective paint coating system throughout structure was found showing failure, with worst locations being located along areasof expansion joint devices as well as structural members near traveled lanes of structure.-Broken light pole KY span.
This inspection was limited to the "Joint Annual Inspection" with ODOT personnel accessing deck area throughout the lowernorthbound lanes and under deck inspection walk system through portion of structure and does not include Element Level or NBIRated portions for structure. This inspection was not a thorough inspection review of structure.For full detailed inspection report of structure see inspection report dated 12/29/2010.
Inspection Notes
8/11/2019 KYTC Bridge Inspections 2007-2013
24/68
tionally Obsolete
8/11/2019 KYTC Bridge Inspections 2007-2013
25/68
Types of Inspections Performed:
National Bridge Inventory: N
Element: N
Fracture Cr itical: N
Underwater: Y
Other Special: N
Summary:
Inspection Date: 8/30/12
Inspector: JJOHNSON (209)
Primary Type: UnWater (60 Months)
Work Candidates
Inspector Candidates: Agency Status Deta
Candidate ID: Status Priority Assigned Action Elem Date Recommended
059-B00046N-1 Approved High Unassigned 60 0 9/16/13
KYTC Bridge Inspection Report059B00046N
Inspection Notes
Damage or deterioration which may have significantly affected the integrity, stability, or load bearing capacity of the observedsubstructure elements was not detected below the water surface. Immediate repairs are not recommended at this time.
Types of Inspections Performed:
National Bridge Inventory: N
Element: N
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/16/11
Inspector: GCOCHRAN (23)
Primary Type: Joint Annual (12 Months)
District Review Date:
District Reviewer:Inspector Signature:
WATERWAY
Scour Critical (113): 8
Observed 113 Rating: U
Waterway Adeq. (71): 9
Load Rating and Posting
Truck Type Typ I Typ II Typ III Typ IV Gross
Recomm. Posting: 36 39 43 66
Field Posting: -1 -1 -1 -1 -1
Posting Status (41): A Open, no restriction
Signs Posted: Cardinal: N Non-Cardinal: N
SCHEDULE TAB
Schedule: Required (Y/N) Last Date Frequency Next Date
NBI (90): 9/16/11 (91): 24 mos 12/2012
Fracture Critical (92A): Y (93A): 12/29/10 (92A): 24 mos 12/29/12
Underwater (92B): Y (93B): 10/10/07 (92B): 60 mos 10/10/12
Other Special (92C): N (93C): 12/29/10 (92C): mos 10/15/09
Elemental: NA 24 mos 12/29/12
NBI CONDITION
Deck (58): 6
Superstructure (59): 6
Substructure (60): 7
Culverts (62): N
Channel/Protection (61): 7
District Number:
County (3):
Feature Intersected (6):
Road Name:
IDENTIFICATION
Bridge ID (8): 059B00046N 059B00046N
Route Carried (7): I-75 I-75
Mile Point: 191.533 191.536
Location (9): BRENT SPENCE BR OVER OHIO BRENT SPENCE BR OVER OHIO
Structure Description:1736.5 Foot - 3 Span Steel continuous
Truss - Thru
1736.5 Foot - 3 Span Steel continuous
Truss - Thru
9/27/11
BSEITER (55)
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
26/68
6 6
59 Kenton 59 Kenton
OHIO RIVER OHIO RIVER
I-75 I-75 NC
8/11/2019 KYTC Bridge Inspections 2007-2013
27/68
Types of Inspections Performed:
National Bridge Inventory: N
Element: N
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/16/11
Inspector: GCOCHRAN (23)
Primary Type: Joint Annual (12 Months)
Element Condition State Data
Str UnitElm/Env Description Description
/
Element Condition State Data
Elm/Env Description Units Total QTY QTY CS1 QTY CS2 QTY CS3 QTY CS4 QTY CS5
/ RROR 0.00 0.00 0.00 0.00 0.00 0.00
Sufficiency Ratings
SR: 59 SD/FO: 2 F
Vertical Clearances
Minimum Vertical Overclearance (53): 14.75 14.75
Minimum Vertical Underclearance (54): 0.00 0.00
Maximum Vertical Clearance (10): 18.33 99.99
Minimum Vertical Clearance: 0.00 99.99
DECK/WEARING SURFACE
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:91.6
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:
KYTC Bridge Inspection Report059B00046N
Structure Notes
*NOTE THAT THIS 2013 JOINT ANNUAL INSPECTION IN CONJUNCTION WITH ODOT WAS PERFORMED ON 09/16/2013.Joint annual inspection notes are as followed:-All needed repairs throughout structure were left in place for detail in the Inspection Notes Tab from last Fracture CriticalInspection dated 12/29/2010 (Entran, PLC).-Structure is in need of varying degrees of rehab construction soon (paint protective coating system, deck surface patching and/
or total overlay project, expansion joint device repairs, under deck inspection walk repairs, etc.).-Deck surface is deteriorating along intermediate expansion joint device locations. Full depth holes/failures are starting to occur/develop in upper deck of structure at two locations near the north end of bridge as evident from view below. Area of deck alongexpansion joint at panel point #7 of the lower deck was found to have an area of full depth failure that was found during JAInspection, which was repaired same by state crew forces.-Under deck inspection walk system as well as the northbound lower most deck was accessed during time of Joint Annual withODOT. Clip angle connections supporting under deck inspection walk system at back side location of floorbeam element #16remains fractured at this time and are no longer operating as designed.-Protective paint coating system throughout structure was found showing failure, with worst locations being located along areasof expansion joint devices as well as structural members near traveled lanes of structure.-Broken light pole KY span.
This inspection was limited to the "Joint Annual Inspection" with ODOT personnel accessing deck area throughout the lowernorthbound lanes and under deck inspection walk system through portion of structure and does not include Element Level or NBIRated portions for structure. This inspection was not a thorough inspection review of structure.
For full detailed inspection report of structure see inspection report dated 12/29/2010.
8/11/2019 KYTC Bridge Inspections 2007-2013
28/68
tionally Obsolete
8/11/2019 KYTC Bridge Inspections 2007-2013
29/68
Types of Inspections Performed:
National Bridge Inventory: N
Element: N
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/16/11
Inspector: GCOCHRAN (23)
Primary Type: Joint Annual (12 Months)
Work CandidatesInspector Candidates: Agency Status Deta
Candidate ID: Status Priority Assigned Action Elem Date Recommended
059-B00046N-1 Approved High Unassigned 60 0 9/16/13
KYTC Bridge Inspection Report059B00046N
Inspection Notes
ENTRAN,PLC on December 29, 2010 completed a fracture critical inspection of the truss bridge. The inspection included datagathering for both NBI and PONTIS element level inspection reporting.
In summary, the Brent Spence Bridge is considered to be in overall fair condition. The following NBI condition ratings wereassigned to the structure: DECK - 6; SUPERSTRUCTURE - 6; PAINT CONDITION - 5; SUBSTRUCTURE - 7
ENTRAN suggests the following maintenance recommendations: repair new and active cracks, replace the bolts and fracturedguide plates of the sliding pins at the upper chord, replace compression seals and repair damaged armored edges, remove rustfrom bearings at expansion joints, clean drains and drain pipes, clean troughs under expansion joints, replace the broken ormissing utility box covers, monitor pack rust and section loss thrhoughout truss, clean and paint the floorbeams and stringers,and repair spalls in deck and barriers.
See the signed 2010 Short Form Report on file for description of the Scope of Work, detailed summary of deficiencies and TC71-118 Bridge Inspection Report.
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: Y
Underwater: N
Other Special: N
Summary:
Inspection Date: 12/29/10
Inspector: MLAWLER (82)
Primary Type: FracCrit (24 Months)
District Review Date:
District Reviewer:Inspector Signature:
SCHEDULE TAB
Schedule: Required (Y/N) Last Date Frequency Next Date
NBI (90): 12/29/10 (91): 24 mos 12/2012
Fracture Critical (92A): Y (93A): 4/1/01 (92A): 24 mos 12/29/12
Underwater (92B): Y (93B): 10/10/07 (92B): 60 mos 10/10/12
Other Special (92C): N (93C): 4/1/01 (92C): mos 10/15/09
NBI CONDITION
Deck (58): 6
Superstructure (59): 6
Substructure (60): 7
Culverts (62): N
Channel/Protection (61): 7
District Number:
County (3):
Feature Intersected (6):
Road Name:
IDENTIFICATION
Bridge ID (8): 059B00046N 059B00046N
Route Carried (7): I-75 I-75
Mile Point: 191.533 191.536
Location (9): BRENT SPENCE BR OVER OHIO BRENT SPENCE BR OVER OHIO
Structure Description:1736.5 Foot - 3 Span Steel continuous
Truss - Thru
1736.5 Foot - 3 Span Steel continuous
Truss - Thru
10/19/10
BSEITER (55)
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
30/68
6 6
59 Kenton 59 Kenton
OHIO RIVER OHIO RIVER
I-75 I-75 NC
8/11/2019 KYTC Bridge Inspections 2007-2013
31/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: Y
Underwater: N
Other Special: N
Summary:
Inspection Date: 12/29/10
Inspector: MLAWLER (82)
Primary Type: FracCrit (24 Months)
Element Condition State Data
Elm/Env Description Units Total QTY QTY CS1 QTY CS2 QTY CS3 QTY CS4 QTY CS5
102/1 Paint Stl Box Girder LF 102.00 0.00 51.00 51.00 0.00 0.00
113/1 Paint Stl Stringer LF 27784.00 13792.00 5556.80 8335.20 100.00 0.00
121/1 P/Stl Thru Truss/Bot LF 3473.00 0.00 2778.40 694.60 0.00 0.00
126/1 P/Stl Thru Truss/Top LF 3473.00 0.00 3125.70 347.30 0.00 0.00
152/1 Paint Stl Floor Beam LF 4763.00 1190.75 2143.35 1428.90 0.00 0.00
205/1 R/Conc Column EA 4.00 3.00 1.00 0.00 0.00 0.00
210/1 R/Conc Pier Wall LF 148.00 133.20 14.80 0.00 0.00 0.00
22/1 P Conc Deck/Rigid Ov SF 159035.00 0.00 159035.00 0.00 0.00 0.00
301/1 Pourable Joint Seal LF 1237.00 0.00 1237.00 0.00 0.00 0.00
303/1 Assembly Joint/Seal LF 367.00 0.00 367.00 0.00 0.00 0.00
311/1 Moveable Bearing EA 164.00 154.00 10.00 0.00 0.00 0.00
Sufficiency Ratings
SR: 59 SD/FO: 2 F
Vertical ClearancesMinimum Vertical Overclearance (53): 14.75 14.75
Minimum Vertical Underclearance (54): 0.00 0.00
Maximum Vertical Clearance (10): 18.33 99.99
Minimum Vertical Clearance: 0.00 99.99
DECK/WEARING SURFACE
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:91.6
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:
WATERWAY
Scour Critical (113): 8
Observed 113 Rating: U
Waterway Adeq. (71): 9
Load Rating and Posting
Truck Type Typ I Typ II Typ III Typ IV Gross
Recomm. Posting: 36 39 43 66
Field Posting: -1 -1 -1 -1 -1
Posting Status (41): A Open, no restriction
Signs Posted: Cardinal: N Non-Cardinal: N
Elemental: NA 24 mos 12/29/12
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
32/68
tionally Obsolete
8/11/2019 KYTC Bridge Inspections 2007-2013
33/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: Y
Underwater: N
Other Special: N
Summary:
Inspection Date: 12/29/10
Inspector: MLAWLER (82)
Primary Type: FracCrit (24 Months)
Element Condition State DataStr UnitElm/Env Description Description
1 102/1 Paint StlBox Girder
Riveted built-up box girder floorbeams exist at UD PP 17 and 17'. The box girder floor beams exhibit
moderate surface rust and section loss of top flange and rivet heads, 10% and 25% respectively. There is
debris from open joint on the top flange of the floorbeam.
1 113/1 Paint StlStringer
The paint has failed and is flaking on the interior upper deck stringers. In locations of expansion joints the
stringers have moderate surface rust with minimal section loss. At some of the splices along the exterior
stringers, pack rust is forming along the edge of the bottom flange splice plate.
1 121/1 P/Stl ThruTruss/Bot
There is pack rust occurring at the lower chord, particularly on the splice plates, filler plates, and cover
plates. There is also pack rust along the edges of the lower chord. Section loss is occurring on the
underside of the lower chord, particularly in the area of the cover plates and splice plates. It is noted up to
50% at the cover plate. There is also section loss on the lower chord at the connection to the vertical
members.
The inboard and outboard gusset plates at the lower chord panel points are generally in good condition.There is surface rust and flaking paint on the gusset plates, and pack rust around the edges of the plates.
In some locations, there is pack rust up to 1 thick that is prying up the gusset plates. There is section
loss up to 1/8 at some locations. See appendix of short form for table of condition states for each gusset
plate.
1 126/1 P/Stl ThruTruss/Top
The top chord members and the gussets plate connections to the verticals, diagonals, and lateral bracing
are generally in good condition. The minor deterioration occasionally observed includes (1) surface rust
and minor pack rust along the edge of gusset plates, (2) minor debris and surface rust inside of the top
chord around the connection bolts for the top chord splices, (3) pack rust along the outside and inside
edges of the top chord member, and (4) pack rust along the edges of the keeper plates.
The truss members (including the vertical and diagonal members) typically have minor surface rust along
the inside and outside corners of the boxes. Also, along the edge of the internal diaphragms, the truss
members have minor to moderate surface rust, pitting, and pack rust. The corrosion is active in some
areas, but the section loss in the primary members is typically between 1/16 and 3/16. There is pack rust
noted up to 3/16 on the inside of the verticals, especially around the interior diaphragms. There is a2x0.75 hole in member L1-U1 upstream with a 3.5 diameter area around the hole going from 100%
section loss to 0% of the 0.5 plate.
See appendix of short form for table of condition states for each gusset plate of the top chord and mid-
height joints.
1 152/1 Paint StlFloor Beam
The floorbeams exhibit section loss and surface rust throughout the bridge. The filler plates of the floor
beams typically have section loss up to 3/16, and there is typically pack rust along these filler plates and
stiffeners. The coverplates often exhibit section loss at this location. Under the expansion joints, there is
heavy corrosion and debris on top of the floor beams.
There are cracks on the T-connections, filler plates, and welds of the floorbeams, including a significant
amount of new cracks in these locations. See appendix of short form for crack location and sizes.
Element Condition State Data
Elm/Env Description Units Total QTY QTY CS1 QTY CS2 QTY CS3 QTY CS4 QTY CS5
313/1 Fixed Bearing EA 4.00 4.00 0.00 0.00 0.00 0.00
331/1 Conc Bridge Railing LF 6946.00 6876.54 0.00 69.46 0.00 0.00
356/1 Steel Fatigue SmFlag EA 1.00 0.00 1.00 0.00 0.00 0.00
357/1 Pack Rust Smart Flag EA 1.00 0.00 1.00 0.00 0.00 0.00
359/1 Soffit Smart Flag EA 1.00 0.00 1.00 0.00 0.00 0.00
604/1 2nd Elem Dist EA 1.00 0.00 1.00 0.00 0.00 0.00
606/1 Drains EA 1.00 0.00 0.00 1.00 0.00 0.00
609/1 Debris on Superstruc EA 1.00 0.00 1.00 0.00 0.00 0.00
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
34/68
8/11/2019 KYTC Bridge Inspections 2007-2013
35/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: Y
Underwater: N
Other Special: N
Summary:
Inspection Date: 12/29/10
Inspector: MLAWLER (82)
Primary Type: FracCrit (24 Months)
Element Condition State Data
Str UnitElm/Env Description Description
1 205/1 R/ConcColumn
There is a crack at Pier 1 that is deep and runs the entire depth of the pier cap and continues through
the column. There is severe map cracking and delamination the full height of the west face of the
upstream column. Otherwise, the piers appear to be in good condition.
1 210/1 R/Conc Pier Wall
Minor cracking was present at the bearing areas.
1 22/1 P ConcDeck/RigidOv
The deck is in overall fair condition. There is transverse and longitudinal cracking throughout the upper
and lower deck. There are failed patches and spalls that are typically next to the expansion joints. There
are locations of spalls with exposed reinforcement. Asphalt patches have failed. There are transverse
cracks throughout the deck.
1 301/1 PourableJoint Seal
1 303/1 AssemblyJoint/Seal
Some of the expansion joints at the ends of the truss show a small amount of vertical misalignment. It is
noted up to 1/2. The troughs under these joints are all filled or overflowing with debris.
1 311/1 Moveable
Bearing
The bearings show fair amounts of surface and pack rust throughout the truss, and heavy pack rust and
active corrosion under the expansion joints. The bearings at the piers are in good condition.
1 313/1 FixedBearing
1 331/1 Conc BridgeRailing
Vertical cracks in the concrete barriers are typical throughout the length of the bridge. The barrier have
isolated areas of spalling.
1 356/1 SteelFatigueSmFlag
There are cracks on the T-connections, filler plates, and welds of the floorbeams, including a significant
amount of new cracks in these locations. See appendix of short form for crack sizes and locations.
1 357/1 Pack RustSmart Flag
There is pack rust occurring at the lower chord, particularly on the splice plates, filler plates, and cover
plates. There is also pack rust along the edges of the lower chord. There is active pack rust between the
gusset plates and the vertical faces of the lower chord.
1 359/1 Soffit SmartFlag
There is spalled concrete around the joints on the bottom of the deck with exposed rebar.
1 604/1 2nd ElemDist
As previously noted, fractured bolts and guide plates where present at U17-U18 and U17'-U18' members
at panel point 17 and 17', respectively.
1 606/1 Drains The deck drains are completely clogged with debris and vegetation. The downspouts are heavilycorroded, to the point of 100% section loss in some locations. The neoprene boots on the downspouts
are worn and cracked.
1 609/1 Debris onSuperstruc
There is moderate debris on top of the floorbeams at locations of expansion joints. Also there is moderate
debris on the cat walk at FB17 and FB17'. The lower chord and diagonal members were cleaned during a
2010 maintenance cleaning project.
KYTC Bridge Inspection Report059B00046N
Structure Notes
8/11/2019 KYTC Bridge Inspections 2007-2013
36/68
8/11/2019 KYTC Bridge Inspections 2007-2013
37/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: Y
Underwater: N
Other Special: N
Summary:
Inspection Date: 12/29/10
Inspector: MLAWLER (82)
Primary Type: FracCrit (24 Months)
Work Candidates
Inspector Candidates: Agency Status Deta
Candidate ID: Status Priority Assigned Action Elem Date Recommended
059-B00046N-1 Approved High Unassigned 60 0 9/16/13
KYTC Bridge Inspection Report059B00046N
Structure Notes
*NOTE THAT THIS 2013 JOINT ANNUAL INSPECTION IN CONJUNCTION WITH ODOT WAS PERFORMED ON 09/16/2013.Joint annual inspection notes are as followed:-All needed repairs throughout structure were left in place for detail in the Inspection Notes Tab from last Fracture Critical
Inspection dated 12/29/2010 (Entran, PLC).-Structure is in need of varying degrees of rehab construction soon (paint protective coating system, deck surface patching and/or total overlay project, expansion joint device repairs, under deck inspection walk repairs, etc.).-Deck surface is deteriorating along intermediate expansion joint device locations. Full depth holes/failures are starting to occur/develop in upper deck of structure at two locations near the north end of bridge as evident from view below. Area of deck alongexpansion joint at panel point #7 of the lower deck was found to have an area of full depth failure that was found during JAInspection, which was repaired same by state crew forces.-Under deck inspection walk system as well as the northbound lower most deck was accessed during time of Joint Annual withODOT. Clip angle connections supporting under deck inspection walk system at back side location of floorbeam element #16remains fractured at this time and are no longer operating as designed.-Protective paint coating system throughout structure was found showing failure, with worst locations being located along areasof expansion joint devices as well as structural members near traveled lanes of structure.-Broken light pole KY span.
This inspection was limited to the "Joint Annual Inspection" with ODOT personnel accessing deck area throughout the lowernorthbound lanes and under deck inspection walk system through portion of structure and does not include Element Level or NBIRated portions for structure. This inspection was not a thorough inspection review of structure.For full detailed inspection report of structure see inspection report dated 12/29/2010.
Inspection Notes
ENTRAN,PLC on December 29, 2010 completed a fracture critical inspection of the truss bridge. The inspection included datagathering for both NBI and PONTIS element level inspection reporting.
In summary, the Brent Spence Bridge is considered to be in overall fair condition. The following NBI condition ratings wereassigned to the structure: DECK - 6; SUPERSTRUCTURE - 6; PAINT CONDITION - 5; SUBSTRUCTURE - 7
ENTRAN suggests the following maintenance recommendations: repair new and active cracks, replace the bolts and fractured
guide plates of the sliding pins at the upper chord, replace compression seals and repair damaged armored edges, remove rustfrom bearings at expansion joints, clean drains and drain pipes, clean troughs under expansion joints, replace the broken ormissing utility box covers, monitor pack rust and section loss thrhoughout truss, clean and paint the floorbeams and stringers,and repair spalls in deck and barriers.
See the signed 2010 Short Form Report on file for description of the Scope of Work, detailed summary of deficiencies and TC71-118 Bridge Inspection Report.
Types of Inspections Performed:
National Bridge Inventory: N
Element: N
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/24/10
Inspector: GCOCHRAN (23)
Primary Type: Standard (24 Months)
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
38/68
8/11/2019 KYTC Bridge Inspections 2007-2013
39/68
Types of Inspections Performed:
National Bridge Inventory: N
Element: N
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/24/10
Inspector: GCOCHRAN (23)
Primary Type: Standard (24 Months)
District Review Date:
District Reviewer:Inspector Signature:
Sufficiency Ratings
SR: 74 SD/FO: 2 F
Vertical Clearances
Minimum Vertical Overclearance (53): 14.75 14.75
Minimum Vertical Underclearance (54): 0.00 0.00
Maximum Vertical Clearance (10): 18.33 99.99
Minimum Vertical Clearance: 0.00 99.99
DECK/WEARING SURFACE
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:91.6
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:
WATERWAY
Scour Critical (113): 8
Observed 113 Rating: U
Waterway Adeq. (71): 9
Load Rating and Posting
Truck Type Typ I Typ II Typ III Typ IV Gross
Recomm. Posting: 36 39 43 66
Field Posting: -1 -1 -1 -1 -1
Posting Status (41): A Open, no restriction
Signs Posted: Cardinal: N Non-Cardinal: N
SCHEDULE TAB
Schedule: Required (Y/N) Last Date Frequency Next Date
NBI (90): 9/24/10 (91): 24 mos 12/2010
Fracture Critical (92A): Y (93A): 4/1/01 (92A): 24 mos 12/3/10Underwater (92B): Y (93B): 10/10/07 (92B): 60 mos 10/10/12
Other Special (92C): N (93C): 4/1/01 (92C): mos 10/15/09
Elemental: NA 24 mos 12/3/10
NBI CONDITION
Deck (58): 6
Superstructure (59): 6
Substructure (60): 7Culverts (62): N
Channel/Protection (61): 7
District Number:
County (3):
Feature Intersected (6):
Road Name:
IDENTIFICATION
Bridge ID (8): 059B00046N 059B00046N
Route Carried (7): I-75 I-75
Mile Point: 191.533 191.536
Location (9): BRENT SPENCE BR OVER OHIO BRENT SPENCE BR OVER OHIO
Structure Description:1736.5 Foot - 3 Span Steel continuous
Truss - Thru
1736.5 Foot - 3 Span Steel continuous
Truss - Thru
10/19/10
BSEITER (55)
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
40/68
tionally Obsolete
6 6
59 Kenton 59 Kenton
OHIO RIVER OHIO RIVER
I-75 I-75 NC
8/11/2019 KYTC Bridge Inspections 2007-2013
41/68
Types of Inspections Performed:
National Bridge Inventory: N
Element: N
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/24/10
Inspector: GCOCHRAN (23)
Primary Type: Standard (24 Months)
Work Candidates
Inspector Candidates: Agency Status Deta
Candidate ID: Status Priority Assigned Action Elem Date Recommended
059-B00046N-1 Approved High Unassigned 60 0 9/16/13
Element Condition State Data
Str UnitElm/Env Description Description
/
Element Condition State Data
Elm/Env Description Units Total QTY QTY CS1 QTY CS2 QTY CS3 QTY CS4 QTY CS5
/ RROR 0.00 0.00 0.00 0.00 0.00 0.00
KYTC Bridge Inspection Report059B00046N
Structure Notes
*NOTE THAT THIS 2013 JOINT ANNUAL INSPECTION IN CONJUNCTION WITH ODOT WAS PERFORMED ON 09/16/2013.Joint annual inspection notes are as followed:-All needed repairs throughout structure were left in place for detail in the Inspection Notes Tab from last Fracture CriticalInspection dated 12/29/2010 (Entran, PLC).
-Structure is in need of varying degrees of rehab construction soon (paint protective coating system, deck surface patching and/or total overlay project, expansion joint device repairs, under deck inspection walk repairs, etc.).-Deck surface is deteriorating along intermediate expansion joint device locations. Full depth holes/failures are starting to occur/develop in upper deck of structure at two locations near the north end of bridge as evident from view below. Area of deck alongexpansion joint at panel point #7 of the lower deck was found to have an area of full depth failure that was found during JAInspection, which was repaired same by state crew forces.-Under deck inspection walk system as well as the northbound lower most deck was accessed during time of Joint Annual withODOT. Clip angle connections supporting under deck inspection walk system at back side location of floorbeam element #16remains fractured at this time and are no longer operating as designed.-Protective paint coating system throughout structure was found showing failure, with worst locations being located along areasof expansion joint devices as well as structural members near traveled lanes of structure.-Broken light pole KY span.
This inspection was limited to the "Joint Annual Inspection" with ODOT personnel accessing deck area throughout the lowernorthbound lanes and under deck inspection walk system through portion of structure and does not include Element Level or NBI
Rated portions for structure. This inspection was not a thorough inspection review of structure.For full detailed inspection report of structure see inspection report dated 12/29/2010.
Inspection Notes
PB Americas, Inc. conducted a fracture critical inspection of the Brent Spence Bridge over the Ohio River. The inspectionincluded data gathering for both NBI and PONTIS element level inspection reporting.In summary, the Brent Spence Bridge is considered to be in overall fair condition. The following NBI condition ratings wereassigned to the structure: DECK - 6; SUPERSTRUCTURE - 6; PAINT CONDITION - 5; SUBSTRUCTURE - 7
No repairs are deemed emergency at this time, PB recommends the following maintenance and repairs in order to maintain andextend the useful service life of the structure. (1) Replace fractured and missing sections of guide plates for the upper chordsliding pins at U17-U18, (2) clean drain inlets and troughs of finger tooth joints, (3) replace pourable joint seals, (4) monitorfatigue cracks in LD floorbeams, (5) replace fractured angles supporting inspection walk at PP16, and (6) paint flooring systemsupporting the upper deck and under expansion joints of both decks.
See the signed 2008 Short Form Report on file for description of the Scope of Work, detailed summary of deficiencies and TC71-118 Bridge Inspection Report.
All core element quantities are from the original plans and the 1985 deck widening plans.
8/11/2019 KYTC Bridge Inspections 2007-2013
42/68
8/11/2019 KYTC Bridge Inspections 2007-2013
43/68
Types of Inspections Performed:
National Bridge Inventory: N
Element: N
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 9/24/10
Inspector: GCOCHRAN (23)
Primary Type: Standard (24 Months)
KYTC Bridge Inspection Report059B00046N
Types of Inspections Performed:
National Bridge Inventory: N
Element: N
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 10/6/09
Inspector: GCOCHRAN (23)
Primary Type: Joint Annual (12 Months)
District Review Date:
District Reviewer:Inspector Signature:
DECK/WEARING SURFACE
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:91.6
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
WATERWAY
Scour Critical (113): 8
Observed 113 Rating: U
Waterway Adeq. (71): 9
Load Rating and Posting
Truck Type Typ I Typ II Typ III Typ IV Gross
Recomm. Posting: 36 39 43 66
Field Posting: -1 -1 -1 -1 -1
Posting Status (41): A Open, no restriction
Signs Posted: Cardinal: N Non-Cardinal: N
SCHEDULE TAB
Schedule: Required (Y/N) Last Date Frequency Next Date
NBI (90): 10/6/09 (91): 24 mos 12/2010
Fracture Critical (92A): Y (93A): 4/1/01 (92A): 24 mos 12/3/10
Underwater (92B): Y (93B): 10/10/07 (92B): 60 mos 10/10/12
Other Special (92C): N (93C): 4/1/01 (92C): mos 10/15/09Elemental: NA 24 mos 12/3/10
NBI CONDITION
Deck (58): 6
Superstructure (59): 6
Substructure (60): 7
Culverts (62): N
Channel/Protection (61): 7
District Number:
County (3):
Feature Intersected (6):
Road Name:
IDENTIFICATION
Bridge ID (8): 059B00046N 059B00046N
Route Carried (7): I-75 I-75
Mile Point: 191.533 191.536
Location (9): BRENT SPENCE BR OVER OHIO BRENT SPENCE BR OVER OHIO
Structure Description:1736.5 Foot - 3 Span Steel continuous
Truss - Thru
1736.5 Foot - 3 Span Steel continuous
Truss - Thru
2/17/10
BSEITER (55)
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
44/68
6 6
59 Kenton 59 Kenton
OHIO RIVER OHIO RIVER
I-75 I-75 NC
8/11/2019 KYTC Bridge Inspections 2007-2013
45/68
Types of Inspections Performed:
National Bridge Inventory: N
Element: N
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 10/6/09
Inspector: GCOCHRAN (23)
Primary Type: Joint Annual (12 Months)
Element Condition State Data
Str UnitElm/Env Description Description
/
Element Condition State Data
Elm/Env Description Units Total QTY QTY CS1 QTY CS2 QTY CS3 QTY CS4 QTY CS5
/ RROR 0.00 0.00 0.00 0.00 0.00 0.00
Sufficiency Ratings
SR: 74 SD/FO: 2 F
Vertical ClearancesMinimum Vertical Overclearance (53): 14.75 14.75
Minimum Vertical Underclearance (54): 0.00 0.00
Maximum Vertical Clearance (10): 18.33 99.99
Minimum Vertical Clearance: 0.00 99.99
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:
KYTC Bridge Inspection Report059B00046N
Structure Notes
*NOTE THAT THIS 2013 JOINT ANNUAL INSPECTION IN CONJUNCTION WITH ODOT WAS PERFORMED ON 09/16/2013.Joint annual inspection notes are as followed:-All needed repairs throughout structure were left in place for detail in the Inspection Notes Tab from last Fracture CriticalInspection dated 12/29/2010 (Entran, PLC).-Structure is in need of varying degrees of rehab construction soon (paint protective coating system, deck surface patching and/or total overlay project, expansion joint device repairs, under deck inspection walk repairs, etc.).-Deck surface is deteriorating along intermediate expansion joint device locations. Full depth holes/failures are starting to occur/
develop in upper deck of structure at two locations near the north end of bridge as evident from view below. Area of deck alongexpansion joint at panel point #7 of the lower deck was found to have an area of full depth failure that was found during JAInspection, which was repaired same by state crew forces.-Under deck inspection walk system as well as the northbound lower most deck was accessed during time of Joint Annual withODOT. Clip angle connections supporting under deck inspection walk system at back side location of floorbeam element #16remains fractured at this time and are no longer operating as designed.-Protective paint coating system throughout structure was found showing failure, with worst locations being located along areasof expansion joint devices as well as structural members near traveled lanes of structure.-Broken light pole KY span.
This inspection was limited to the "Joint Annual Inspection" with ODOT personnel accessing deck area throughout the lowernorthbound lanes and under deck inspection walk system through portion of structure and does not include Element Level or NBIRated portions for structure. This inspection was not a thorough inspection review of structure.For full detailed inspection report of structure see inspection report dated 12/29/2010.
Inspection Notes
8/11/2019 KYTC Bridge Inspections 2007-2013
46/68
tionally Obsolete
8/11/2019 KYTC Bridge Inspections 2007-2013
47/68
Types of Inspections Performed:
National Bridge Inventory: N
Element: N
Fracture Cr itical: N
Underwater: N
Other Special: N
Summary:
Inspection Date: 10/6/09
Inspector: GCOCHRAN (23)
Primary Type: Joint Annual (12 Months)
Work CandidatesInspector Candidates: Agency Status Deta
Candidate ID: Status Priority Assigned Action Elem Date Recommended
059-B00046N-1 Approved High Unassigned 60 0 9/16/13
KYTC Bridge Inspection Report059B00046N
Inspection Notes
PB Americas, Inc. conducted a fracture critical inspection of the Brent Spence Bridge over the Ohio River. The inspectionincluded data gathering for both NBI and PONTIS element level inspection reporting.In summary, the Brent Spence Bridge is considered to be in overall fair condition. The following NBI condition ratings were
assigned to the structure: DECK - 6; SUPERSTRUCTURE - 6; PAINT CONDITION - 5; SUBSTRUCTURE - 7
No repairs are deemed emergency at this time, PB recommends the following maintenance and repairs in order to maintain andextend the useful service life of the structure. (1) Replace fractured and missing sections of guide plates for the upper chordsliding pins at U17-U18, (2) clean drain inlets and troughs of finger tooth joints, (3) replace pourable joint seals, (4) monitorfatigue cracks in LD floorbeams, (5) replace fractured angles supporting inspection walk at PP16, and (6) paint flooring systemsupporting the upper deck and under expansion joints of both decks.
See the signed 2008 Short Form Report on file for description of the Scope of Work, detailed summary of deficiencies and TC71-118 Bridge Inspection Report.
All core element quantities are from the original plans and the 1985 deck widening plans.
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: Y
Underwater: N
Other Special: N
Summary:
Inspection Date: 12/3/08
Inspector: MBARON (89)
Primary Type: SIA (Initial Inventory
District Review Date:
District Reviewer:Inspector Signature:
SCHEDULE TAB
Schedule: Required (Y/N) Last Date Frequency Next Date
NBI (90): 12/3/08 (91): 24 mos 12/2010
Fracture Critical (92A): Y (93A): 4/1/01 (92A): 24 mos 12/3/10
Underwater (92B): Y (93B): 10/10/07 (92B): 60 mos 10/10/12
Other Special (92C): N (93C): 4/1/01 (92C): mos 10/15/09
NBI CONDITION
Deck (58): 6
Superstructure (59): 6
Substructure (60): 7
Culverts (62): N
Channel/Protection (61): 7
District Number:
County (3):
Feature Intersected (6):
Road Name:
IDENTIFICATION
Bridge ID (8): 059B00046N 059B00046N
Route Carried (7): I-75 I-75
Mile Point: 191.533 191.536
Location (9): BRENT SPENCE BR OVER OHIO BRENT SPENCE BR OVER OHIO
Structure Description:1736.5 Foot - 3 Span Steel continuous
Truss - Thru
1736.5 Foot - 3 Span Steel continuous
Truss - Thru
3/3/09
BSEITER (55)
KYTC Bridge Inspection Report059B00046N
8/11/2019 KYTC Bridge Inspections 2007-2013
48/68
6 6
59 Kenton 59 Kenton
OHIO RIVER OHIO RIVER
I-75 I-75 NC
8/11/2019 KYTC Bridge Inspections 2007-2013
49/68
Types of Inspections Performed:
National Bridge Inventory: Y
Element: Y
Fracture Cr itical: Y
Underwater: N
Other Special: N
Summary:
Inspection Date: 12/3/08
Inspector: MBARON (89)
Primary Type: SIA (Initial Inventory
Element Condition State Data
Elm/Env Description Units Total QTY QTY CS1 QTY CS2 QTY CS3 QTY CS4 QTY CS5
102/1 Paint Stl Box Girder LF 102.00 77.00 25.00 0.00 0.00 0.00
113/1 Paint Stl Stringer LF 27784.00 12792.00 1000.00 13892.00 100.00 0.00
121/1 P/Stl Thru Truss/Bot LF 3473.00 0.00 3473.00 0.00 0.00 0.00
126/1 P/Stl Thru Truss/Top LF 3473.00 0.00 3473.00 0.00 0.00 0.00
152/1 Paint Stl Floor Beam LF 4763.00 2383.00 0.00 2380.00 0.00 0.00
205/1 R/Conc Column EA 4.00 3.00 1.00 0.00 0.00 0.00
210/1 R/Conc Pier Wall LF 148.00 138.00 10.00 0.00 0.00 0.00
22/1 P Conc Deck/Rigid Ov SF 159035.00 0.00 159035.00 0.00 0.00 0.00
301/1 Pourable Joint Seal LF 1237.00 0.00 1237.00 0.00 0.00 0.00
303/1 Assembly Joint/Seal LF 367.00 0.00 367.00 0.00 0.00 0.00
311/1 Moveable Bearing EA 164.00 155.00 9.00 0.00 0.00 0.00
Sufficiency Ratings
SR: 59 SD/FO: 2 F
Vertical ClearancesMinimum Vertical Overclearance (53): 14.75 14.75
Minimum Vertical Underclearance (54): 0.00 0.00
Maximum Vertical Clearance (10): 18.33 99.99
Minimum Vertical Clearance: 0.00 99.99
DECK/WEARING SURFACE
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:91.6
Deck Type (107): 1 Concrete-Cast-In-Place
Wearing Surface/Protective System (108): Type: 3 Membrane: 0 Protection: 0
Traffic Safety Features (36): Bridge Rail: 1 Transition: 1 Appr. Rail: 1 Rail Ends: 1
Overlay: Y
Overlay Type: Latex (34) Skew: 0
Overlay Thickness: -1 (51) Curb-to-Curb Width:
WATERWAY
Scour Critical (113): 8
Observed 113 Rating: _
Waterway Adeq. (71): 9
Load Rating and Posting
Truck Type Typ I Typ I