6
LASER…INNOVATION MADE IN GERMANY www.arclaser.de [email protected] KTP LASER Photocoagulation System h Two laser ports (Option) h Intuitive, single touch control dial selects treatment parameters h CLASSIC + PCL5 SH: Laser delivery and slit lamp illumination are ALWAYS coaxial

KTP LASER2018_03_Classic_PCL5_ZL... · Fiber Attachments 2 Fiber ports Accessories Indirect Ophthalmoscope / Endo Probes * at fi ber end The device and the delivery system is protected

  • Upload
    habao

  • View
    216

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KTP LASER2018_03_Classic_PCL5_ZL... · Fiber Attachments 2 Fiber ports Accessories Indirect Ophthalmoscope / Endo Probes * at fi ber end The device and the delivery system is protected

LASER…INNOVATION MADE IN GERMANY

www.arclaser.de [email protected]

K T P L A S E R

A.R.C. Laser GmbHBessemerstr. 1490411 NurembergGermany

A.R.C. Laser GmbHBessemerstr. 1490411 NurembergGermany

� +49 911 217 79-0� +49 911 217 79 [email protected]

� +49 911 217 79-0� +49 911 217 79 [email protected]

Your local distributor:

A.R

.C. L

aser

cer

tifi e

s th

at th

e pr

oduc

t com

plie

s to

21

CFR

104

0.10

and

104

0.11

EN

134

85/

2003

- 9

3/42

EW

G

A.R.C. Laser GmbHBessemerstraße 14D-90411 NürnbergGermany

+49 (0) 911 217 79-0 +49 (0) 911 217 79 [email protected]

Your local distributor:

A.R

.C. L

aser

cer

tifi e

s th

at th

e pr

oduc

t com

plie

s to

21

CFR

104

0.10

and

104

0.11

EN

134

85/

2003

- 9

3/42

EW

G

Photocoagulation System

h Two laser ports (Option)

h Intuitive, single touch control dial selects treatment parameters

h CLASSIC + PCL5 SH: Laser delivery and slit lamp illumination are ALWAYS coaxial

Spe

cific

atio

ns a

re s

ubje

ct to

cha

nge

with

out n

otic

e.70

1PC

L5.0

3201

8EN

Page 2: KTP LASER2018_03_Classic_PCL5_ZL... · Fiber Attachments 2 Fiber ports Accessories Indirect Ophthalmoscope / Endo Probes * at fi ber end The device and the delivery system is protected

PCL 5 ZL

PCL 5 ZLS L I T L A M P & L A S E R

The laser optic of the PLC5 is unique because it enables coagu-

lation in the periphery, which is a dramatic difference from other

slit lamps where the illumination comes from below.

The laser optic is integrated into the slit illumination to assure

coaxial viewing with laser delivery. The compact laser console

can be positioned either to the right or the left of the slit lamp.

Since the connecting cables are concealed, the surgeon can

operate the laser without any restrictions.

The small laser package fits easily into any office setting.

Portability can be enhanced by selecting a slit lamp table with

wheels (optional).

Page 3: KTP LASER2018_03_Classic_PCL5_ZL... · Fiber Attachments 2 Fiber ports Accessories Indirect Ophthalmoscope / Endo Probes * at fi ber end The device and the delivery system is protected

PCL 5 SHL

PCL 5 SHLS L I T L A M P & L A S E R

The SUPER STAR of Photocoagulation Systems! Precision

optics combined with a fully coaxial laser coupled to the slit

lamp, sets the new standard in today’s market. Unique features

such as the neutral colour design filter and the noiseless

micromanipulator combined with the hand trigger enables the

ultimate in performance of laser photocoagulation. With the

laser console on the table, all functions are easily accessible by

your finger tips from the base of the slit lamp.

It’s what is known as PERFECTION.

Ligh

t

Lase

r

SuperView: The optic design assures coaxial viewing with laser delivery.

Page 4: KTP LASER2018_03_Classic_PCL5_ZL... · Fiber Attachments 2 Fiber ports Accessories Indirect Ophthalmoscope / Endo Probes * at fi ber end The device and the delivery system is protected

CLASSICG R E E N L A S E R

An optional battery pack allows “cable free” use inside the OR – maximizing convenience.

The Classic is not only a photocoagulator, but is a device

that can be configured to best satisfy your needs.

Protection filters automatically switch in or out, which allows

a perfect view when the laser is not is use.

With up to 1.5 Watts of power available to the cornea, it is

possible to consider the Classic for multiple applications.

The laser is compact, light weight and portable. The large

display screen is highly visible from every angle.

Adaptors to a selection of slit lamps and operating micro-

scopes are available.

Automatic or permanent Neutral Color filter design.

Choose from a wide range of contact lenses.

Easy transport and stow away with the tailored transportation case.

Page 5: KTP LASER2018_03_Classic_PCL5_ZL... · Fiber Attachments 2 Fiber ports Accessories Indirect Ophthalmoscope / Endo Probes * at fi ber end The device and the delivery system is protected

PCL 5 ZL

A.R.C. Laser GmbHBessemerstraße 14D-90411 NürnbergGermany

+49 (0) 911 217 79-0 +49 (0) 911 217 79 [email protected]

Your local distributor:

A.R

.C. L

aser

cer

tifi e

s th

at th

e pr

oduc

t com

plie

s to

21

CFR

104

0.10

and

104

0.11

EN

134

85/

2003

- 9

3/42

EW

G

Precise spot size selections from a minimum

of 50 µm up to a maximum of 600 µm using the

noiseless pneumatic micromanipulator is the

new standard in laser photocoagulation today.

Select from 5 magnification levels to achieve

the best optical view. The Neutral Color

Design noiseless KTP filter is permanently

installed. The single hand operation of the

slit lamp allows ease of maneuverability

especially when using a contact lens.

Page 6: KTP LASER2018_03_Classic_PCL5_ZL... · Fiber Attachments 2 Fiber ports Accessories Indirect Ophthalmoscope / Endo Probes * at fi ber end The device and the delivery system is protected

CLASSIC

A.R.C. Laser GmbHBessemerstr. 1490411 NurembergGermany

A.R.C. Laser GmbHBessemerstr. 1490411 NurembergGermany

� +49 911 217 79-0� +49 911 217 79 [email protected]

� +49 911 217 79-0� +49 911 217 79 [email protected]

Your local distributor:

A.R

.C. L

aser

cer

tifi e

s th

at th

e pr

oduc

t com

plie

s to

21

CFR

104

0.10

and

104

0.11

EN

134

85/

2003

- 9

3/42

EW

G

A.R.C. Laser GmbHBessemerstraße 14D-90411 NürnbergGermany

+49 (0) 911 217 79-0 +49 (0) 911 217 79 [email protected]

Your local distributor:

A.R

.C. L

aser

cer

tifi e

s th

at th

e pr

oduc

t com

plie

s to

21

CFR

104

0.10

and

104

0.11

EN

134

85/

2003

- 9

3/42

EW

G

A.R.C. Laser GmbHBessemerstraße 14D-90411 NürnbergGermany

+49 (0) 911 217 79-0 +49 (0) 911 217 79 [email protected]

Your local distributor:

A.R

.C. L

aser

cer

tifi e

s th

at th

e pr

oduc

t com

plie

s to

21

CFR

104

0.10

and

104

0.11

EN

134

85/

2003

- 9

3/42

EW

G

CLASSIC IS COMPACT AND EXTREMELY VERSATILE – ONE DEVICE, WITH MANY OPTIONS

Laser KTP - 532 nm

Output power 1.5 Watt max.

Pulse length 10 ms to cw

Pulse interval 100 ms to 1,000 ms

Frequency 1 to 9 Hz

Aiming beam 635 nm, 1 mW max.

Adapters Different slit lamps

Foot print 250 x 190 x 52 mm

Weight 3.3 kg - Complete

Power supply Rechargeable Batteries or 90 to 230 VAC

Fiber Attachments 2 Fiber ports

Accessories Indirect Ophthalmoscope / Endo Probes

* at fi ber endThe device and the delivery system is protected by one or more patents. Technical data may change without notice.

Laser KTP - 532 nm (green)

Output power 1.5 Watt max.

Pulse length 10 ms to cw

Pulse interval 100 ms to 1,000 ms

Frequency 1 to 9 Hz

Aiming beam 635 nm, < 1 mW

Foot print 250 x 190 x 52 mm

Weight 3.3 kg - Complete

Power supply Rechargeable Batteries or 90 to 230 VAC

Fiber attachments 1 Slit-Lamp-Fiber-Port

Accessories opt. Indirect Ophthalmoscope / Endo Probes

* at fi ber end.The device and the delivery system is protected by one or more patents. Technical data may change without notice.

Laser KTP - 532 nm

Output power 1.5 Watt max.

Pulse length 10 ms to cw

Pulse interval 100 ms to 1,000 ms

Frequency 1 to 9 Hz

Aiming beam 635 nm, 1 mW max.

Foot print 250 x 190 x 52 mm

Weight 3.3 kg - Complete

Power supply Rechargeable Batteries or 90 to 230 VAC

Fiber attachments 2nd fi ber port

Accessories opt. Indirect Ophthalmoscope / Endo Probes

* at fi ber end.The device and the delivery system is protected by one or more patents. Technical data may change without notice.

LASER RADIATIONAVOID EXPOSURE TO BEAM

CLASS 3 B LASER PRO-DUCT

532 nm, P < 3 Watt 635 nm, P < 1 mW

VISIBLE AND INVISIBLE LASER RADIATIONAVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION

KTP LASER 532 nm < 3 Watt CWDIODE LASER 635 nm < 1 mW CW

LASER RADIATIONAVOID EXPOSURE TO BEAM

CLASS 3 B LASER PRO-DUCT

532 nm, P < 3 Watt 635 nm, P < 1 mW

VISIBLE AND INVISIBLE LASER RADIATIONAVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION

KTP LASER 532 nm < 3 Watt CWDIODE LASER 635 nm < 1 mW CW

Laser KTP - 532 nm (grün)

Ausgangsleistung 1,5 Watt max.

Pulslänge 10 ms - cw

Puls-Pause 100 ms - 1.000 ms

Wiederholfrequenz 1 bis 9 Hz

Zielstrahl 635 nm, < 1 mW

Stellfl äche 250 x 190 x 52 mm

Gewicht 3,3 kg - komplett

Netzteil- Anschluss 90 - 230 VAC

Laser Ausgänge 1 fest integrierte Fiberkopplung Technische Änderungen vorbehalten.

Laser KTP - 532 nm (green)

Output power 1.5 Watt max.

Pulse length 10 ms to cw

Pulse interval 100 ms to 1,000 ms

Frequency 1 to 9 Hz

Aiming beam 635 nm, < 1 mW

Foot print 250 x 190 x 52 mm

Weight 3.3 kg - Complete

Power supply 90 - 230 VAC / optional Akkubetrieb

Fiber attachments 1 Endo-Fiber-Port

Accessories opt. Indirect Ophthalmoscope / Endo Probes

Technische Änderungen vorbehalten.

Laser KTP - 532 nm (grün)

Ausgangsleistung 1,5 Watt max.

Pulslänge 10 ms - cw

Puls-Pause 100 ms - 1.000 ms

Wiederholfrequenz 1 bis 9 Hz

Zielstrahl 635 nm, < 1 mW

Stellfl äche 250 x 190 x 52 mm

Gewicht 3,3 kg - komplett

Netzteil- Anschluss 90 - 230 VAC / optional Akkubetrieb

Laser Ausgänge optional 2 Fibereinkopplungen

Zubehör Indirektes Ophthalmoskop / Endo-Sonden

Technische Änderungen vorbehalten.

TECHNISCHE DATEN SPECIFICATIONS

TECHNISCHE DATEN

SPECIFICATIONS SPECIFICATIONS

SPECIFICATIONS

SICHTBARE UND UNSICHTBARE LASERSTRAHLUNGBestrahlung von Auge oder Haut durch direkte oder Streustrahlung vermeiden.LASER KLASSE 4 532 nm, P < 3 Watt / 635 nm, P < 1 mW

SICHTBARE UND UNSICHTBARE LASERSTRAHLUNGBestrahlung von Auge oder Haut durch direkte oder Streustrahlung vermeiden.LASER KLASSE 4 532 nm, P < 3 Watt / 635 nm, P < 1 mW

SICHTBARE UND UNSICHTBARE LASERSTRAHLUNGBestrahlung von Auge oder Haut durch direkte oder Streustrahlung vermeiden.LASER KLASSE 4 532 nm, P < 3 Watt / 635 nm, P < 1 mW

LASER RADIATIONAVOID EXPOSURE TO BEAM

CLASS 3 B LASER PRO-DUCT

532 nm, P < 3 Watt 635 nm, P < 1 mW

VISIBLE AND INVISIBLE LASER RADIATIONAVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION

KTP LASER 532 nm < 3 Watt CWDIODE LASER 635 nm < 1 mW CW

Slit width 0 to 16 mm continuous

Slit length 0.5 to 16 mm continuous

Illumination field diameter 0.2, 1, 2, 3, 4, 6, 8 mm

Slit rotation ± 90° (0-180°)

Illumination unit swing horizontal ± 90°

Filters blue, redfree (green), grey (10%)UV and IR filter are pre installed

Illumination Halogen 6 V, 20 W0 lux to 600,000 lux (Halogen)optional: LED 14 V, 5 W

Eye protection filter permanent

Laser optic parfocal 50 - 600 µm

Power requ. 110 V - 240 V 50/60 Hz

Weight 12.7 kg

PCL5 ZL

CLASSIC GREEN LASER

SPECIFICATIONS SLIT LAMPS

PCL5 SHL

LIO

Slit width 0 to 8 mm continuous

Slit length 1 to 8 mm continuous

Illumination field diameter 0.2, 1, 2, 3, 4, 6, 8 mm

Slit rotation ± 90° (0-180°)

Illumination unit swing horizontal ± 90° vertical 0-20°

Filters blue, redfree (green), grey (10%)UV and IR filter are built-in

Illumination Halogen 6 V, 20 W0 lux to 600,000 lux (Halogen)optional: LED 14 V, 5 W

Eye protection filter permanent

Laser optic parfocal 50 - 600 µm

Power requ. 110 V - 240 V 50/60 Hz

Weight 12.7 kg

Stereo microscope

Stereo angle full 10°

Oculars ± 7 diopters

Magnification 6.3x / 10x / 16x / 25x / 40x

Pupillar distance 52 to 78 mm

Spe

cific

atio

ns a

re s

ubje

ct to

cha

nge

with

out n

otic

e.

Laser Indirect Ophthalmoscope in combination with our CLASSIC. Eqipped with eye protection filter and coaxial coupling.

h Slit Lamp Adaptors

h Microscope usage with a selection of Endo Probes

h Laser Indirect Ophthalmoscope (LIO)

h and more....

Our commitment is to supply our customers with the best quality products with the latest innovations and broadest range of accessories – available from a single source.

A.R.C. Laser in Germany is a privately held company to better serve you.

ENDO-Probes single use

20 G straight LL13009s

21 G straight LL13011s

curved 30° LL13014s

23 G straight LL13006s

curved 30° LL13025s

FLEX-Endo LL11057s

25 G straight LL13010s

curved 30° LL13015s

Diopexy-Probe straight LL13012s

ENDO PROBESA.R.C. Laser offers a selection of single use probes at an affordable price.

with PCL5 ZL or PCL5 SHL with PCL5 ZL or PCL5 SHL

701P

CL5

.032

018E

N