80
5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words NOTE, IMPORTANT, CAUTION, WARNING or DANGER are used to call your attention to important information. The definition of each of these terms follows: NOTE: Indicates a special point of information or addresses a machine adjustment. IMPORTANT: Indicates information which, if not heeded, could result in damage to the machine. CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate personal injury. WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious personal injury. DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious personal injury. Before beginning installation, read completely through these instructions. Using the shipping order and/or the Contents Listings section at the end of these instructions, check to be sure you have all the packages needed to complete assembly. The information used in these instructions was current at the time of printing. However, due to KINZE’s continual attempts to improve its product, production changes may cause your planter to appear slightly different in detail. KINZE Manufacturing, Inc. reserves the right to change specifications or design without notice and without incurring obligation to install the same on machines previously manufactured. Right hand (R.H.) and left hand (L.H.), as used throughout these instructions, are determined by facing in the direction the machine will travel when in use, unless otherwise stated. DANGER: Always install all safety lockup devices or lower planter to the ground before working under or around the unit. Monitor Serial No. ______________________________________________________________ Measured Pulses Per Mile/km (Radar Distance Sensor) _______________________________ Measured Pulses Per Mile/km (Magnetic Distance Sensor) ____________________________ Rev. 0/06

KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

� 5/06

KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS

IS676 Rev. 9/07

Throughouttheseinstructionsthesymboland/orthewords NOTE, IMPORTANT, CAUTION, WARNING or DANGER areusedtocallyourattentiontoimportantinformation.Thedefinitionofeachofthesetermsfollows:

NOTE: Indicates a special point of information or addresses a machine adjustment.

IMPORTANT: Indicates information which, if not heeded, could result in damage to the machine.

CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate personal injury.

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious personal injury.

DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious personal injury.

Beforebeginninginstallation,readcompletelythroughtheseinstructions.

Usingtheshippingorderand/ortheContentsListingssectionattheendoftheseinstructions,checktobesureyouhaveallthepackagesneededtocompleteassembly.

Theinformationusedintheseinstructionswascurrentatthetimeofprinting.However,duetoKINZE’scontinualattemptstoimproveitsproduct,productionchangesmaycauseyourplantertoappearslightlydifferentindetail.KINZEManufacturing,Inc.reservestherighttochangespecificationsordesignwithoutnoticeandwithoutincurringobligationtoinstallthesameonmachinespreviouslymanufactured.

Righthand(R.H.)andlefthand(L.H.),asusedthroughouttheseinstructions,aredeterminedbyfacinginthedirectionthemachinewilltravelwheninuse,unlessotherwisestated.

DANGER: Always install all safety lockup devices or lower planter to the ground before working under or around the unit.

Monitor Serial No. ______________________________________________________________

Measured Pulses Per Mile/km (Radar Distance Sensor) _______________________________

Measured Pulses Per Mile/km (Magnetic Distance Sensor) ____________________________

Rev.�0/06

Page 2: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

� 5/06

TheKPMIIIElectronicSeedMonitorPackageconsistsof(a)aKPMIIIconsole,whichismountedonthetractor;(b)seedtubeswithsensors,oneofwhichisinstalledineachplanterrowunit;(c)amagneticdistancesensor,whichisinstalledontheplanter,oraradardistancesensor,whichisinstalledonthetractor;(d)ashaftrotationsensorkit(Models3�40,3�00,3600,3600TR,3650,3700,3700SDS,3800,3800SDSonly),whichisinstalledontheplanterdrillshafts;and(e)planterharnesses(junctionY-harnessand/orextensionharnesswhereapplicable),towhichtheindividualseedtubesensorsconnect.Theprimaryharness,whichconnectsthemonitorconsoletotheplanterharness,ishardwiredintothesafety/warninglightharnessorcontrolconsoleharnessincludedasstandardequipmentwiththeplanter.

Themonitorispoweredbythetractorbattery(requires��voltsDC).

INTRODUCTION IS676

(MTR��)(MTR�7b) (MTR�7yy)

KPM III Backlit Console

NOTE: If the console is not installed in the tractor at the time of planter installation, the console must be connected to a 12 volt power source before any of the planter components can be programmed when plugged into the planter harness. See “Connecting Seed Tubes, Shaft Rotation Sensors, Seed Tubes And/Or Radar/Magnetic Distance Sensors”.

Model 3000/3110/3140 Stack Folding/3200/3400/3500/3600/3650/3700/3800 Planters

Radar Distance Sensor Magnetic (Pickup) Distance Sensor (MDS) Shaft Rotation Sensor

D�0�9050�

Rev.7/07

Page 3: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

3 5/06

TABLE OF CONTENTS IS676

TRACTOR COMPONENTS INSTALLATION

STEP�.InstallConsole......................................................................................................................................4

STEP�.ConnectPower......................................................................................................................................5

STEP3.InstallRadarDistanceSensor (ApplicableOnlyToKPMIIIWithRadarDistanceSensor).................................................................................6

PLANTER COMPONENTS INSTALLATION

STEP�.InstallSeedTubesIntoRowUnits........................................................................................................8 STEP�.InstallDrillShaftRotationSensors (ApplicableonlytoModel3�40StackFolding,Model3�00,Model3600,Model3600TRModel3650, Model3700andModel3800PlantersequippedwithKPMIIIMonitor)............................................................�0

STEP3.InstallMagneticDistanceSensor(ApplicableOnlyToKPMIIIWithMagneticDistanceSensor).......��

STEP4.InstallHarnessesBetweenConsoleAndSeedTubes........................................................................�3 Model3000.........................................................................................................................................�4 Model3��0.........................................................................................................................................�5 Model3�40.........................................................................................................................................�6 Model3�00.........................................................................................................................................�8 Model3400.........................................................................................................................................�0 Model3500.........................................................................................................................................�� Model3600.........................................................................................................................................�� Model3600TR....................................................................................................................................�4 Model3650.........................................................................................................................................�6 Model3700.........................................................................................................................................�8 Model3800.........................................................................................................................................30

OPERATION Introduction.......................................................................................................................................................3� MonitorKeyFunctions......................................................................................................................................33 ConfiguringPlanterMonitor.............................................................................................................................34 Programming/ConnectingSeedTubes,ShaftRotationSensorsAnd/OrRadar/MagneticDistanceSensors...36 ChangingVolume,ContrastAndBacklighting...................................................................................................38 ProgrammingInterplant®Condition,RowSpacingAndUnits(MetricOrEnglish)............................................39 ProgrammingRowUnitAlarmsLevels..............................................................................................................40 SpeedSensorCalibration/Programming...........................................................................................................4� ReprogrammingSpeedSensor.........................................................................................................................4� AddingInterplant®Rows(IfRearRowsHavePreviouslyBeenProgrammed).................................................46 AddingEven-RowPackage(IfFrontRowsHavePreviouslyBeenProgrammed)............................................48 Enabling/DisablingInterplant®Rows.................................................................................................................50 WarningsAndAlarms.......................................................................................................................................53 ReplacingFaultySensor(s)...............................................................................................................................6� FieldOperation..................................................................................................................................................55 AreaManagement............................................................................................................................................56 AreaCounters...................................................................................................................................................58 ClearingFieldArea...........................................................................................................................................59 AcreCountMode..............................................................................................................................................59CONTENTS LISTINGS ...........................................................................................................................................6�

Rev.7/07

Page 4: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

4 5/06

TRACTOR COMPONENTS INSTALLATION IS676

STEP 1 Install console.

Installtheconsoleonthetractorwhereitcanbeeasilyviewedandoperatedbutnotobstructtheoperator’sview.Ifrequired,optionaladjustablearmsareavailablefromaftermarketsuppliers.

Using themountingballasa template,mark the locationof the threeor fourbracketmountingholes. Drill 7∕32"diameterholes.

(MTR48/MTR49)

CAUTION: Make sure the opposite side of the drilling surface has ample clearance and is free of wiring, etc.

AttachthefirstmountingbrackettothemountingsurfaceusingthreeNo.�0-�4x¾"capscrews,flatwashers,lockwashersandhexnutsprovided.

AttachsecondmountingbrackettoKPMIIIconsole.

SecureKPMIIIconsoletomountingbracketusingtheadjustablearm.TightentheT-bolttolocktheconsoleinthedesiredposition.

Flat Washers, LockWashersAndHexNuts

MountingSurface

KPM III CONSOLE INSTALLATION

No.�0-�4x¾"CapScrews

D��0405�0/D�0�9050�

T-Bolt

NOTE: An optional 10" monitor/radar adapter cable (GA9144) is available for use between the console and radar distance sensor to adapt the monitor system to various tractor radar systems. DO NOT CONNECT THE ADAPTER TO THE CONSOLE AT THIS TIME.

Rev.�0/06

Page 5: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

5 5/06

TRACTOR COMPONENTS INSTALLATION IS676

STEP 2 Connect power.

Themonitorsystemoperateson��VDConly.Theconsolepowerleadhasa3-terminalAMPCPCfemaleconnectorwhichcanbeconnectedtotheconvenienceoutletprovidedinlatemodeltractors.

Use GA7856 power lead adapter (customer-supplied) if a two wire connection is needed.Connectthe“red”wiretothepositive(+)batteryterminalandthe“black”wiretothenegative(-)batteryterminal.Refertothefollowingillustrationsfortypicalbatteryconnections.(MTR�6a)

Ifyourtractor’sbatteryarrangementisdifferentthanshownorifthereisanyquestionastowheretoconnectthepowerlead,useavoltmetertomakesureyoumeasurefrom��voltsto�4voltsacrossthe“red”and“black”leads.Ontractorsusing two��voltbatteries,makesureconsolepower leadsareconnecteddirectly to thegroundedbattery.

NOTE: Good battery connections are essential for proper monitor operation. Make sure connections are clean and tight. If the console is connected to less than 10 volts or more than 15 volts, an audible alarm will sound and a message will be displayed on the screen.

NOTE: The battery, ignition and electrical system of the tractor must be in good working order.

Securepowerleadwithtiestrapsfurnishedwithconsole.DONOTrouteconsolepowerleadincloseproximitytoexistingbatterycables.

Power Lead

Power Lead

Power Lead

Power Lead

Power Lead

Negative (-) Ground System

24 Volt System

12V

12V

12V 6V6V 6V

6V

6V

6V

Vehicle Ground

24V StartingRelay Bank

Red

Black

Black

Red

Bla

ck

Red

Black

Red

Red

Black

Positive (+) Ground System

D09��0��0� 03�99703

KPM III Monitor System Power Lead Adapter (GA7856)

Power Lead

Page 6: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

6 5/06

TRACTOR COMPONENTS INSTALLATION IS676

STEP 3 Install radar distance sensor. (Applicable Only To KPM III With Radar Distance Sensor)

A. Installradarsensorontomountingbracketusingfour¼"-�0x½"capscrewsandlockwashersasshownbelow.Besurecutoutsinbracketarefacingawayfromtheradarsensor.

(MTR33)

B. Drilltwoholesinthemountingsurfaceandinstallpipebracket.Installpipebracketontotractorusingtwo⅜"-�6x�"capscrews,lockwashersandhexnuts.Priortoinstallationofthepipebracketontothetractor,readthefollowingprecautionsandrecommendations.

• Installtheradardistancesensorapproximately�feetabovetheground. • Theradardistancesensorshouldbemountedfacingrearwardformorephysicalprotectiontothesensor. • Theradardistancesensorshouldnotbemountedincloseproximitytoanymajorheatsources. • Thefaceoftheradardistancesensormusthaveanunobstructedviewoftheground. • Theradardistancesensorshouldbelocatedwherefluidsdonotdripdirectlyontheunit. • Themountingshouldofferaminimalamountofvibrationpotential.Excessivevibrationmaycauseerroneous

speedreadingswhenthetractorisstationary. • Theradardistancesensormustbemountedsoit“sitsontop”oftherubbervibrationbushings.Itshouldnot

bemountedsoithangsfromtherubberbushings.

NOTE: Welding the bracket is not recommended in case the radar distance sensor needs to be relocated due to vibration problems.

C. Installradarsensor/mountingbracketontopipebracketusingtwo¼"-�0U-bolts,flatwashers,lockwashersandhexnuts.TightentheU-boltsjustenoughsotheradarsensorcanstillbetippedbyhand.

RubberVibrationBushings

A.¼"-�0x½"CapScrewsAndLockWashers

C.¼"-�0 U-Bolts, Flat Washers,LockWashersAndHexNuts

B.⅜"-�6x�"CapScrews,LockWashersAndHexNuts

Rev.�0/06

Page 7: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

7 5/06

E. Withthetractorparkedonaflatsurface,placealevelsoitalignswiththearrowedlineontheradarsensor.Tiptheradarsensoruntilthebubbleonthelevelisbalancedatmid-linewhichwillplacethesensorata35°angle.TightentheU-boltstosecuretheradarsensormountingbrackettothepipebracket.

(MTR34) 053�9808

F. Routethecablefromtheradarsensortotheproperlocationandsecurewithtiestraps.Usecareinroutingcabletoavoidsourcesofheatorareasthatmaypinchordamagethecable.

IMPORTANT: DO NOT CONNECT radar distance sensor to the monitor system at this time. See “Programming/

Connecting Seed Tubes, Shaft Rotation Sensors And/Or Radar/Magnetic Distance Sensors”.

NOTE: If the monitor is using the tractor’s radar for ground speed input, a customer supplied Y-cable may be required to complete the installation.

NOTE: After installation of the radar distance sensor or any time the sensor is moved, the console must be calibrated. See “Speed Sensor Calibration/Programming” in this instruction or in the Operation Section of the Operator & Parts Manual supplied with the planter.

NOTE: Excessive vibration may cause ground speed (MPH or KM/H) readings to be above zero when the tractor is stationary. To check for vibration, start tractor engine and slowly increase engine RPM (while watching the ground speed readout) to approximately 1800 RPM. If the ground speed readings are above zero, the radar distance sensor must be mounted in an alternate, more stable location.

TRACTOR COMPONENTS INSTALLATION IS676

RadarGunAt35°Angle

Level

RadarGunAt35°Angle

Rev.�0/06

Page 8: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

8 5/06

PLANTER COMPONENTS INSTALLATION IS676

STEP 1 Install seed tubes into row units.

Insertseedtubew/sensorintoplanterrowunitshankandroutethesensorleadtowardtheplantertoolbar.Positionseedtubehookoverlowercrosspinasillustratedbelow.Replaceupperclevispinthroughholesonupperpartofseedtubeassembly.Replacehairpincliponclevispin.Extendsensorleadtowardplantertoolbarasshownonthefollowingpage.Securesensorleadtorowunitwithtiesprovided,allowingslackinleadformovementofparallellinkage.

ClevisPinAndHairPinClip

Lower CrossPin

METR55b/D0��5050�/RU�38a

RedLED(LightEmittingDiode)

BlueConnector

Rev.�0/06

GA10901 Seed Tube W/Sensor

(MECHANICAL SEED METERING)

GA11948 Seed Tube W/Sensor

(EDGEVAC®

SEED METERING)

Page 9: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

9 5/06

NOTE: Make sure sensor lead cannot be damaged by parallel linkage movement or come in contact with drill shaft. DO NOT CONNECT SENSOR LEAD TO PLANTER HARNESS AT THIS TIME.

PLANTER COMPONENTS INSTALLATION IS676

D�0�700�08

Push Row Unit Sensor Lead Routing

D070799�43a

Pull Row Unit Sensor Lead Routing

Rev.�0/06

Page 10: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�0 5/06

PLANTER COMPONENTS INSTALLATION IS676

09�09708

A. Placetophalfofactuatoroverbottomhalfandsnapthesensoractuatorontothedrillshaftasshownatright.

NOTE: DO NOT SLIDE the halves together.

B. BoltplasticcoverontoeachsideofactuatorusingtwoNo.8-3�x�¼"stainlesssteelmachinescrews,lockwashersandnuts.Seephotoatrightandillustrationabove.

0��899��

(PLTR�85a)

STEP 2 Install drill shaft rotation sensors. (Applicable Only To Model 3140 Stack Folding, Model 3200, Model 3600, Model 3600TR, Model 3650,

Model 3700 And Model 3800 Planters Equipped With KPM III Monitor)

Install thedrillshaftrotationsensorsontothesupportplatesontothetoolbarbetweenrowunitasshownintheillustrationsonpages�6through3�.Inmostapplicationstherotationsensorwillbeinstalledbetweentheoutermostrowunitoneachsideoftheplanter.

G1K364 Rota t ion Sensor Mounting Kit (Two Bolts W/Hardware And Two Mounts)

Rev.7/07

Page 11: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�� 5/06

PLANTER COMPONENTS INSTALLATION IS676PLTR�85a

C. InstallsensorontomountusingthetwoNo.�0panheadscrews,SAEwashersandnutsasshownatright.DONOTtightenscrewsatthistime.

D. Positionassemblyoverdrillshaftasshown.

E. Positionspringmountunderrowunitmountingsupportplateandconnectspringsasshownabove.

F. Centersensoroveractuatorwithmaximum⅛"gapbetweensensorandactuator.Tightensensormountinghardware.

G. RepeatStepsAthroughGonoppositeendofplanter.

IMPORTANT: DO NOT CONNECT drill shaft rotation sensor to the planter harness at this time. The drill shaft rotation sensors will be connected when the seed tubes are connected.

Rev.7/07

D07�407�03

D07�407�0�

Maximum⅛"GapBetweenSensorAndActuator

Page 12: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�� 5/06

PLANTER COMPONENTS INSTALLATION IS676

STEP 3 Install magnetic distance sensor. (Applicable Only To KPM III With Magnetic Distance Sensor)

SeeinstallationinstructionsuppliedwithMagnetic Distance Sensor Package (A6�47forModel3000,3��0Rigid,3�40StackFolding,3�00,3400,3500,3600,3650,3700and3800Planters)forinstallationofthatpackage.

Seeillustrationsonpages�4through3�forinstallationlocationsasapplicable.Secureadapterwithtiestraps.

IMPORTANT: DO NOT CONNECT magnetic distance sensor adapter to the planter harness at this time.

Magnetic Distance Sensor (MDS) Adapter - Connect To Magnetic Distance Sensor Lead

Connect MDS Adapter To MDS Lead. See Installation Instruction Supplied With MDS Package.

0��899�003�9970�

Three Pin To Harness

Two Pin To MDS

Rev.7/07

Page 13: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�3 5/06

PLANTER COMPONENTS INSTALLATION IS676

B. Primary Harness(es)

Tractor Wiring Harness

A. Planter Harness

(IfApplicable)Monitor/RadarAdapterDONOTCONNECTATTHISTIME

D. Power Lead Adapter

Safety/Warning Light Harness

Planter Wiring Harness

(If Applicable) MagneticDistanceSensor(MDS)DONOT CONNECT AT THISTIME

(MTR46cc/A9�5�/ELC�0e/ELC�0d/MTR5�)

STEP 4 Install harnesses between console and seed tubes.

NOTE 1: DO NOT connect seed tubes to harness during this step.

NOTE 2: When installing harnesses, take care to locate harnesses where they will not be pinched, cut or damaged by any moving parts during normal operation of the planter.

Refer to the illustrations on the following pages for additional information.

A. Layplanterharness(es)outontopofplanterframe.Eachplanterharnesswillhave more connectors thanneededforthenumberofplanterrowunits.Forexample,a��rowharnesswillhave�6connectorsanda�6rowharnesswillhave�0connectors.Inadditiontoseedtubeconnections,oneconnectorisusedtoconnecttheplanterharnesstothemonitorconsoleonthetractor.AsecondadditionalconnectorisusedforMDShookup(IfApplicable)orforusewithanoptionalextensionharnesstoaddanadditionallengthofplanterharness.Extraconnectorsmayalsobeusedtoconnectthedrillshaftrotationsensors(IfApplicable).

NOTE: DO NOT CONNECT harness to any sensors at this time.

B. Install extension harness whereapplicable. See the following pagesfor model specif ic instal lat ioninstructions.

NOTE: The primary harness is included in the safety/warning light wiring harness or tractor and planter control console wiring harnesses.

C. ConnectharnessesinstalledinStepsAandBtoeachother.

D. Connect console to a �� volt powersource. See STEP � in “TractorComponentsInstallation”.

B. Extension Harness

Rev.�0/06

NOTE: Be sure planter light wiring harness is connected to the planter monitor harness.

Page 14: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�4 5/06

NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to the planter harness and the sensor cable on the console is not used. Bundle and tie any unused harness connectors to the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.

MODEL 3000 PULL TYPE PLANTER WITH INTERPLANT® PACKAGE

(8 Row With 7 Push Row Units Shown)(PLTR��6i)

PLANTER COMPONENTS INSTALLATION IS676

JunctionHarnessSuppliedWithInterplant®MonitorPackage

PlanterHarness4RowPlanter-HarnessHas7Connectors6RowPlanter-HarnessHas9Connectors8RowPlanter-HarnessHas��Connectors

PlanterHarnessSuppliedWithInterplant®MonitorPackage

PrimaryHarnessIncludedinsafety/warninglightwiringharness.

MDSAdapter(IfApplicable)ConnectedtomagneticdistancesensorleadinSTEP3.

(MTR�7ee/MTR47)

R1 R2 R3 R4 R5 R6 R7 R8

F1 F2 F3 F4 F5 F6 F7

Page 15: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�5 5/06

MODEL 3110 THREE POINT MOUNTED PLANTER (Rigid Frame)

(8 Row Shown)

(PLTR��7h)

PlanterHarness6RowPlanter-HarnessHas9Connectors8RowPlanter-HarnessHas��Connectors

PrimaryHarnessIncludedinsafety/warninglightwiringharness.

NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to the planter harness and the sensor cable on the console is not used. Bundle and tie any unused harness connectors to the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.

R1 R2 R3 R4 R5 R6 R7 R8

PLANTER COMPONENTS INSTALLATION IS676

MDSAdapter(IfApplicable)ConnectedtomagneticdistancesensorleadinSTEP3.

(MTR�7ee/MTR47)

Rev.7/07

Page 16: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�6 5/06

MODEL 3140 THREE POINT MOUNTED PLANTER (Stack Folding)

(8 Row Shown)(PLTR��9a)

PlanterHarness(Wing)8RowPlanter-HarnessHas7Connectors��RowPlanter-HarnessHas7Connectors�6RowPlanter-HarnessHas7Connectors

PlanterHarness(CenterSection)8RowPlanter-HarnessHas9Connectors��RowPlanter-HarnessHas��Connectors�6RowPlanter-HarnessHas�6Connectors

ExtensionHarnessDrillShaftRotationSensorSeeSTEP�

NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to the planter harness and the sensor cable on the console is not used. Bundle and tie any unused harness connectors to the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.

R1 R2 R3 R4

PLANTER COMPONENTS INSTALLATION IS676

Rev.7/07

Page 17: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�7 5/06

PrimaryHarnessIncludedinsafety/warninglightwiringharness.

PlanterHarness(Wing)8RowPlanter-HarnessHas7Connectors��RowPlanter-HarnessHas7Connectors�6RowPlanter-HarnessHas7Connectors

ExtensionHarness

MDSAdapter(IfApplicable)ConnectedtomagneticdistancesensorleadinSTEP3.

(MTR�7ee/MTR47)

R5 R6 R7 R8

PLANTER COMPONENTS INSTALLATION IS676

DrillShaftRotationSensorSeeSTEP�

Rev.7/07

Page 18: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�8 5/06

MODEL 3200 FLEX ECONO-FOLD® PLANTER

(12 Row Shown)

(PLTR�48b/PLTR�48c)

NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to the planter harness and the sensor cable on the console is not used. Bundle and tie any unused harness connectors to the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.

PlanterHarness��RowPlanter-HarnessHas�6Connectors

DrillShaftRotationSensorSeeSTEP�

R1 R2 R3 R4 R5 R6

PLANTER COMPONENTS INSTALLATION IS676

Rev.7/07

Page 19: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�9 5/06

PrimaryHarnessIncludedinsafety/warninglightwiringharness.

DrillShaftRotationSensorSeeSTEP�

MDSAdapter(IfApplicable)ConnectedtomagneticdistancesensorleadinSTEP3.

(MTR�7ee/MTR47)

R7 R8 R9 R10 R11 R12

PLANTER COMPONENTS INSTALLATION IS676

Rev.7/07

Page 20: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�0 5/06

MODEL 3400 TWIN-LINE® PLANTER WITH INTERPLANT® PACKAGE

(12 Row With 11 Push Row Units Shown)(PLTR�47i/MTR�7ee/MTR47)

PlanterHarness��RowPlanter-HarnessHas�6Connectors

PlanterHarnessSuppliedWithInterplant®MonitorPackage

NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to the planter harness and the sensor cable on the console is not use. Bundle and tie any unused harness connectors to the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.

JunctionY-HarnessSuppliedwithInterplant®MonitorPackage

MDSAdapter(IfApplicable)ConnectedtomagneticdistancesensorleadinSTEP3.

PrimaryHarnessIncludedinplanterwiringharness.Connectleadsatvalveblocklocatedontopofcenterframe.

F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11

R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12

PLANTER COMPONENTS INSTALLATION IS676

Page 21: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�� 5/06

MODEL 3500 TWIN-LINE® PLANTER WITH INTERPLANT® PACKAGE

(8 Row With 7 Push Row Units Shown)

(PLTR���r)

PlanterHarness6RowPlanter-HarnessHas9Connectors8RowPlanter-HarnessHas��Connectors

JunctionY-HarnessSuppliedWithInterplant®MonitorPackage

PlanterHarnessSuppliedWithInterplant®MonitorPackage

PrimaryHarnessAndExtensionHarness(es)ToSafety/WarningLightOnL.H.RearPlanterFrameIncludedinsafety/warninglightwiringharness.

NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to the planter harness and the sensor cable on the console is not used. Bundle and tie any unused harness connectors to the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.

MDSAdapter(IfApplicable)ConnectedtomagneticdistancesensorleadinSTEP3.

(MTR�7ee/MTR47)

F1 F2 F3 F4 F5 F6 F7

PLANTER COMPONENTS INSTALLATION IS676

R1 R2 R3 R4 R5 R6 R7 R8

Page 22: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�� 5/06

MODEL 3600 TWIN-LINE® PLANTER WITH INTERPLANT® PACKAGE

(12 Row With 11 Push Row Units Shown)(PLTR�3�h/PLTR�3�d)

PlanterHarness8RowPlanter-HarnessHas��Connectors��RowPlanter-HarnessHas�6Connectors�6RowPlanter-HarnessHas�0Connectors

PlanterHarnessSuppliedWithInterplant®MonitorPackage

NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to the planter harness and the sensor cable on the console is not used. Bundle and tie any unused harness connectors to the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.

F1 F2 F3 F4 F5

R1 R2 R3 R4 R5 R6

PLANTER COMPONENTS INSTALLATION IS676

DrillShaftRotationSensorSeeSTEP�

NOTE: On 8 and 12 row sizes equipped with Interplant® Package, the drill shaft rotation sensors will have to be installed on the 2nd row in on each side of the planter to avoid interference with the Interplant® Package drive.

Rev.7/07

Page 23: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�3 5/06

MDSAdapter(IfApplicable)ConnectedtomagneticdistancesensorleadinSTEP3.

JunctionY-HarnessSuppliedWithInterplant®MonitorPackage

PrimaryHarnessIncludedintheplanterwiringharness.Connecttoleadsfromhydrauliccontrolharnesslocatedonrearcenterframe.

(MTR�7ee/MTR47)

F6 F7 F8 F9 F10 F11

R7 R8 R9 R10 R11 R12

PLANTER COMPONENTS INSTALLATION IS676

DrillShaftRotationSensorSeeSTEP�

NOTE: On 8 and 12 row sizes equipped with Interplant® Package, the drill shaft rotation sensors will have to be installed on the 2nd row in on each side of the planter to avoid interference with the Interplant® Package drive.

Rev.7/07

Page 24: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�4 5/06

PLANTER COMPONENTS INSTALLATION IS676

Rev.7/07

MODEL 3600TR TWIN-LINE® PLANTER

(16 Row Shown)(TWL�86)

R1 R2 R3 R4 R5 R6 R7 R8

F6 F7 F8F1 F2 F3 F4 F5

DrillShaftRotationSensorSeeSTEP�

NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to the planter harness and the sensor cable on the console is not used. Bundle and tie any unused harness connectors to the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.

PlanterHarness��RowPlanter-HarnessHas�6Connectors�6RowPlanter-HarnessHas�0Connectors

Page 25: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�5 5/06

PLANTER COMPONENTS INSTALLATION IS676

Rev.7/07

R9 R10 R11 R12 R13 R14 R15 R16

F9 F10 F11 F12 F13 F14 F15 F16

DrillShaftRotationSensorSeeSTEP�

MDSAdapter(IfApplicable)ConnectedtomagneticdistancesensorleadinSTEP3.

(MTR�7ee/MTR47)

JunctionY-HarnessSuppliedWithInterplant®KPMIIIMonitorPackage

PrimaryHarnessIncluded in the planter wiring harness. Connect toleadsfromhydrauliccontrolharnesslocatedonrearcenterframe.

Page 26: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�6 5/06

MODEL 3650 TWIN-LINE® PLANTERS WITH INTERPLANT® PACKAGE

(Model 3650 SDS 12 Row With 11 Push Row Units Shown)(TWL�54)

PlanterHarness��RowPlanter-HarnessHas�6Connectors�6RowPlanter-HarnessHas�0Connectors

PlanterHarnessSuppliedWithInterplant®Stack-ModeMonitorPackage

NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to the planter harness and the sensor cable on the console is not used. Bundle and tie any unused harness connectors to the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.

F1 F2 F3 F4 F5

R1 R2 R3 R4 R5 R6

PLANTER COMPONENTS INSTALLATION IS676

DrillShaftRotationSensorSeeSTEP�

Rev.7/07

Page 27: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�7 5/06

MDSAdapter(IfApplicable)ConnectedtomagneticdistancesensorleadinSTEP3.

JunctionY-HarnessSuppliedWithInterplant®Stack-ModeMonitorPackage

PrimaryHarnessIncluded in the planter wiring harness. Connect toleadsfromhydrauliccontrolharnesslocatedonrearcenterframe.

(MTR�7ee/MTR47)

PLANTER COMPONENTS INSTALLATION IS676

DrillShaftRotationSensorSeeSTEP�

F6 F7 F8 F9 F10 F11

R7 R8 R9 R10 R11 R12

Rev.7/07

Page 28: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�8 5/06

MODEL 3700 FRONT FOLDING PLANTER

(24 Row 30" Shown)(FF94)

PlanterHarness-LeftPlanterWing�4RowPlanter-HarnessHas�6Connectors36RowPlanter-HarnessHas��Connectors

Left Draft Link

DrillShaftRotationSensorSeeSTEP�

NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to the planter harness and the sensor cable on the console is not used. Bundle and tie any unused harness connectors to the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.

MDSAdapter(IfApplicable)ConnectedtomagneticdistancesensorleadinSTEP3.

(MTR�7ee/MTR47)

R7 R8R1 R2 R3 R4 R5 R6

PLANTER COMPONENTS INSTALLATION IS676

30'ExtensionHarnessSuppliedWithPlanterConnect30'extensionharnessfromleftdraftlinktoharnessleadaheadofrightdraftlink.Connecttoolbarendof30'extensionharnesstoplanterharness.

R9 R10 R11 R12

Rev.7/07

Page 29: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

�9 5/06

PlanterHarness-RightPlanterWing�4RowPlanter-HarnessHas�6Connectors36RowPlanter-HarnessHas��Connectors

PrimaryHarnessIncludedinexistingplanterwiringharness.Connectleadsatvalveblocklocatedonrightplanterwingtoplanterharnesssuppliedwithmonitorpackage.

Right Draft Link

DrillShaftRotationSensorSeeSTEP�

R13 R14 R15 R16 R17 R18 R19 R20

PLANTER COMPONENTS INSTALLATION IS676

R21 R22 R23 R24

Rev.7/07

Page 30: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

30 5/06

R13 R14 R15 R16

MODEL 3800 FORWARD FOLDING PLANTER

(32 Row 30" Shown)(FDW4a)

PlanterHarness-LeftPlanterWing�4RowPlanter-HarnessHas�4Connectors3�/36RowPlanters-HarnessesHave�8Connectors

DrillShaftRotationSensorSeeSTEP�

NOTE: If the radar distance sensor is being installed, it is connected to the radar sensor cable on the console and the extra connector on the planter harness is not used. If the magnetic distance sensor is being installed, it is connected to the planter harness and the sensor cable on the console is not used. Bundle and tie any unused harness connectors to the harness so they will not be damaged. DO NOT connect distance sensor or seed tubes at this time.

R7 R8R1 R2 R3 R4 R5 R6

PLANTER COMPONENTS INSTALLATION IS676

R9 R10 R11 R12

Install�5'extensionharnesstoconnectplanterharnesson left wing to planterharnessoncentersection.

Connectexistingplanterwiringharnessleadsatthedraftlinklocatedonleftplanterwingtoplanterharness.

DrillShaftRotationSensorSeeSTEP�

Rev.7/07

Page 31: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

3� 5/06

DrillShaftRotationSensorSeeSTEP�

R17 R18 R19 R20

MDSAdapter(IfApplicable)ConnectedtomagneticdistancesensorleadinSTEP3.

(MTR�7ee/MTR47)

PLANTER COMPONENTS INSTALLATION IS676

R21 R22 R23 R24 R25 R26 R27 R28 R29 R30 R31 R32

PlanterHarness-RightPlanterWing�4RowPlanter-HarnessHas�4Connectors3�/36RowPlanters-HarnessesHave�8Connectors

PlanterHarness-SixCenterRows�4/3�/36RowPlanters-HarnessesHave7Connectors

DrillShaftRotationSensorSeeSTEP�

Connectexistingplanterwiringharnessleadsatthedraftlinklocatedonrightplanterwingtoplanterharness.

Rev.7/07

Page 32: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

3� 5/06

OPERATION IS676

The monitor system is powered by the tractorbattery(requires��voltsDC).Theconsolereceivesinformationfromeachofthesensorsanddisplaysthisinformation.TheKPMIIIconsoleusesasinglebacklitLiquidCrystalDisplay(LCD)toshow,thenumberofmonitoredrows,the relative seed rate for each row (usingbargraphdisplays) and displays various alarm and warningmessageswhenanalarmconditionexists.Acontinuousaudiblealarmwillsounduponsystemmalfunctionorunderflow conditions for any monitored row. Alarmsmustbeacknowledgedbytheuser.Variouswarningsmaysoundthealarmorflashoneormoremessages.TheLCDalsoshowsalphanumericdatasuchasrowspacing, units (Metric or English), speed (MPH orKM/H),volume,seedpopulation,seedspacing,fieldareaandtotalarea.

Themonitorsystemwillpowerdownifnoactivity isdetectedwithinonehour.Noactivitymeanstherehasbeen no new seed flow and no operator push keyinput.

TheKPMIIIelectronicseedmonitorsystemconsistsof(a)aKPMIIIconsole,whichismountedonthetractor;(b)seedtubeswithsensors,oneofwhichisinstalledineachplanterrowunit;(c)amagneticdistancesensor,whichisinstalledontheplanter,oraradardistancesensor,whichisinstalledonthetractor;(d)shaftrotationsensors(ifapplicable),whichareinstalledontheplanterdrillshafts;and(e)planterharnesses(junctionY-harnessand/orextensionharnesswhereapplicable),towhichtheindividualseedtubesensorsconnect.Theprimaryharness,whichconnects themonitorconsole to theplanterharness,ishard-wiredintothesafety/warninglightharnessorcontrolconsoleharnessincludedasstandardequipmentwiththeplanter.

The software design of the KPM III console allowssimultaneous viewing of seed flow bargraphs forstandard and/or Interplant® System rows (up to 36rows).

INTRODUCTION

D�0�9050�

Rev.7/07

Page 33: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

33 5/06

OPERATION IS676

ROTARY ENCODER KNOB• Turnknobclockwiseto

increaseorcounterclockwisetodecreasevalueofitem.

• Turnknobclockwisetoscrolluporcounterclockwisetoscrolldown.

• Pressknobtoenterselection.

AV (AUDIO/VIDEO) KEY• Setalarmvolume.• Adjustthecontrast.• AdjustbacklightingoftheLCD

display.

ACK (ACKNOWLEDGE) KEY• Usedtosilence(acknowledge)

thewarningalarmwhenvariouserrorconditionsoccur.

NOTE: Alarms can be viewed by pressing the STATUS key.

ARROW KEYS• UParrowkeyisusedto

increasethevalueofanitembyoneortoscrollup.

•DOWNarrowkeyisusedtodecreasethevalueofanitembyoneortoscrolldown.

• LEFTarrowkeymultipliesthenumericvalueoftheitemby�0.

• RIGHTarrowkeydividesthenumericvalueoftheitemby�0.

PHYSICAL KEYS• LocatedonR.H.sideof

consoleandreferredtoasF�,F�,F3,F4,F5andF6

• KeysarereferencedindescendingorderwithF�atthetopandF6atthebottom.

ON/OFF KEY• Powerstheunitonandoff.

ESC KEY• UsedastheCANCEL

(escape)key.

ENTER KEY• Confirmsoracceptsthe

highlightedselection.

MONITORKEYFUNCTIONS

Push keys allow the user to select or change theoperating mode, the active displays or the currentconfiguration.Dependingontheoperatingmodeorthecurrentdisplayselected,somekeysmaynotbeactive.Eachkeypress,ifvalid,isacknowledgedbyashortbeepandanactionistaken.Ifthekeypresshasnoactionassociated,thekeypressisconsideredinvalid,andtheuserwillnotreceivefeedback.

PhysicalKeys

RotaryEncoderKnob

AVKey

ON/OFF

D�0�9050�

ENTER

NOTE: Within the LCD, the black box around the smaller box as shown below indicates which field is selected/highlighted. Turning the rotary encoder knob or pressing the UP or DOWN arrow keys moves the black box. When the black box is positioned on a programmable item, such as Shaft Sensors, Speed Sensor, Front Row Units or Rear Row Units, pressing the knob or ENTER key will highlight the programmable item. A programmable item may only be changed when it is highlighted.D0��406�6

Rev.�0/06

Page 34: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

34 5/06

OPERATION IS676

CONFIGURINGPLANTERMONITOR

WhentheKPMIII ispoweredon for thefirst time itwillgodirectlyintothe‘‘PlanterConfiguration’’screen(STEP4).

STEP 1 Press the F6 key until ‘‘Mode Selection’’screenappears.

STEP 4 PresstheknoborENTERkey,tohighlightthe‘‘ShaftSensors’’field.Enterthenumberof‘‘ShaftSensors’’ by turning theknoborusingtheUPorDOWNarrowkeys.WhenthecorrectvalueisdisplayedpresstheknoborENTERkey.Theblackboxwilladvanceto‘‘SpeedSensor’’field.

NOTE: The numeric value may be changed only if the item is highlighted. Turning the rotary encoder knob increases or decreases the value of the item. The UP arrow key may be used to increase the value of the item by one and the DOWN arrow key may be used to decrease the value of the field by one.

D0��406�4

STEP 2 Select‘‘SetupMode’’byturningtherotaryencoder knob or using the UP or DOWNarrowkeys.PresstheknoborENTERkeytodisplayhighlighteditem.

STEP 3 Select‘‘ConfigurePlanterMonitor’’byturningtheknoborusingtheUPandDOWNarrowkeys.PresstheknobortheENTERkeytodisplaythehighlighteditem.

NOTE: The planter monitor cannot be reconfigured while planting.

NOTE: If the monitor has already been configured the message shown below will appear.D0��40634

D0��406�4

D053�060�

Rev.�0/06

Page 35: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

35 5/06

OPERATION IS676

NOTE: To prevent the configuration from being saved press ESC or select the CANCEL button, then press the rotary encoder knob or ENTER key.

STEP 6 Iftherearefrontrowsontheplanter,pressthe knob or ENTER key to highlight the‘‘FrontRowUnits’’ field. Turn theknoborusetheUPorDOWNarrowkeystoobtaincorrectnumberofpushrowunits.PresstheknoborENTERkeywhendesiredquantityisdisplayed.Theblackboxwilladvanceto‘‘RearRowUnits’’field.IfnofrontrowsneedtobeenteredsimplyturntheknoborpresstheDOWNarrowkeytoadvanceto‘‘RearRowUnits’’.

STEP 5 PresstheknoborENTERkeyandadropdownmenuwillappear;selecteither‘‘Radar’’or‘‘CoilPick-Up’’(MDS)byturningtheknoborusingtheUPorDOWNarrowkeys.Whenthe desired selection is highlighted presstheknoborENTERkey.Theblackboxwilladvanceto‘‘FrontRowUnits’’field.

D053�0604

STEP 7 PresstheknoborENTERkeytohighlightthe‘‘RearRowUnits’’field.TurntheknoborusetheUPorDOWNarrowkeystoobtaincorrectnumberofpullrowunits.PresstheknoborENTERkeywhendesiredquantityisdisplayed.TheblackboxwilladvancetotheOKkey.

STEP 8 PresstheknobortheENTERkeytosavetheinformation.

D053�0606

D053�0607

D053�0605

Page 36: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

36 5/06

OPERATION IS676

PROGRAMMING/CONNECTINGSEEDTUBES,SHAFTROTATIONSENSORSAND/ORRADAR/

MAGNETICDISTANCESENSORS

STEP 9 The monitor screen shown below willappear.

Ifthenewplanterconfigurationistobesavedturn the knob or press the UP or DOWNarrow keys to select the OK button thenpresstheknoborENTERkeytosavetheplanterconfigurationintotheKPMIII.IfthemonitorconfigurationisnottobechangedselecttheCANCELkey,presstheknoborENTERkeytoCANCELorpresstheESCkey.

IfOKisselectedthemonitorwilladvanceto‘‘SensorSetup’’(STEP4inPROGRAMMING/CONNECTING SEED TUBES, SHAFTROTATION SENSORS AND/OR RADAR/MAGNETIC DISTANCE SENSORSsection).

NOTE: STEP 9 does not apply if configuring the monitor for the first time.

STEP 1 Toenter‘‘ModeSelection’’,pressF6keyuntilthe‘‘ModeSelection’’screenappears.

STEP 2 Select‘‘SetupMode’’by turning therotaryencoder knob or press the UP or DOWNarrowkeys.PresstheknoborENTERkeytodisplaythehighlighteditem.

STEP 3 Select‘‘SensorSetup’’byturningtheknoborusingtheUPorDOWNarrowkeys.PresstheknoborENTERkeytodisplaythehighlighteditem.

D0��4064�

D0���060�a

STEP 4 AttachtheplanterharnesstotheKPMIII.DoNOTconnectanyofthesensorstotheplanterharness.With[AutoDetect]selectedpresstheINSTALLkey.

D0��40634

Rev.�0/06

Page 37: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

37 5/06

OPERATION IS676

NOTE: After each sensor has been installed ‘‘OK’’ will appear after the sensor name.

STEP 6 If‘‘OK’’appearsbehindALLsensors,pressthe knob or the ENTER key to save theconfiguration.The‘‘SetupMode’’menuwillthenappear.

NOTE: If ‘‘NONE’’ appears after a sensor, the sensor was not recognized. All sensors must be disconnected from the planter harness and reconnected as described in STEP 5.

NOTE: If ‘‘OK slow’’ appears after a sensor, the sensor is able to communicate but at a slower speed. For the system to run at top speed of 9600 baud the slow sensor must be replaced.

D0���060�b

STEP 5 Pluginthefirstseedsensor(row�),workingfromlefttorightandreartofront(rearrowunitsandfrontnextifapplicable).Whenasensorisconnectedtotheplanterharnesswaitforthemonitortoacknowledgewithtwobeeps.

Continue connecting seed sensors alongwithshaftrotationsensorsorspeedsensors.Progress will reflect on the LCD screen.Theexamplebelow indicates that the lastseedsensorfoundwasFrontRow7andthemonitorislookingforthenextsensor.

WhenallsensorsareinstalledpresstheF�keytoendtheinstallation.

D0��706�7

STEP 7 Toreturnto“PlantingMode”selectthePLANTkeyorpresstheF6keyuntil“PlantingMode”screenappears.

D053�0609

Rev.6/07

Page 38: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

38 5/06

OPERATION IS676

CHANGINGVOLUME,CONTRASTANDBACKLIGHTING

The alarm volume and LCD screen contrast andbacklightingmaybeadjustedatanytime,regardlessofwhatisdisplayedonthescreen.

STEP 1 PresstheAVkey.ThespeakeradjustmentdialogboxwillappearinthelowerL.H.cornerofthedisplay.

STEP 2 UsetheLEFTandRIGHTarrowsorturntherotary encoder knob to adjust the volume.Thevolumeof thesoundemitted from thespeakerchangesastheadjustmentisbeingmade.

STEP 3 Toadjustcontrastorbacklight,gotoSTEP4.IffinishedpressENTERtosaveandexit.

STEP 4 Press the AV button a second time. Thecontrast adjustment dialog box will appearinthelowerportionofthedisplay.

D053�06��

STEP 5 UsetheLEFTandRIGHTarrowsorturntheknob to adjust contrast. The effect of theadjustmentwillbevisibleonthedisplay.

STEP 6 ToadjustbacklightinggotoSTEP7.IffinishedpressENTERtosaveandexit.

STEP 7 PresstheAVbuttonathirdtime.ThebacklightadjustmentdialogboxwillappearinthelowerL.H.cornerofthedisplay.

D053�06��

STEP 8 UsetheLEFTandRIGHTarrowsorturntheknobtoadjustbacklighting.Theeffectoftheadjustmentwillbevisibleonthedisplay.

STEP 9 Presstheknob,ENTERorpresstheAVbuttonafourthtimetosavethevolume,contrastandbacklightsettings.Thebacklightadjustmentdialogboxwilldisappear.

D053�06�0

Rev.�0/06

Page 39: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

39 5/06

OPERATION IS676

PROGRAMMINGINTERPLANT®CONDITION,ROWSPACINGANDUNITS(MetricOrEnglish)

STEP 1 Toenter‘‘ModeSelection’’screenpresstheF6keyuntil‘‘ModeSelection’’screenappears.

STEP 2 Select‘‘SetupMode’’by turningtherotaryencoder knob or using the UP or DOWNarrowkeys.PresstheknoborENTERkeytodisplaythehighlighteditem.

STEP 3 Select‘‘GeneralSettings’’byturningtheknoborusingtheUPorDOWNarrowkeys.PresstheknobortheENTERkeytodisplaythehighlighteditem.

D0��406�4

D0��406�5

NOTE: When English is selected inches are displayed, if Metric is selected centimeters are displayed.

D0��406�6

STEP 4 PresstheknoborENTERkeyandadropdown menu will appear. Select either‘‘Enabled’’(pushrowunitsarebeingusedforplanting)or‘‘Disabled’’(pushrowunitsarenotbeingusedforplantingandnoseedratealarmswillbegeneratedforthefrontrows;nobargraphsaretobedisplayedforthefrontrowsandthefrontrowsdonotcontributetotheaveragepopulationandspacingoracrecounts).UsetheknoborUPorDOWNarrowkeystomakeselection.PresstheknoborENTERkeytoselecthighlighteditem.Theblack box will advance to “Row Spacing”field.

Rev.�0/06

Page 40: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

40 5/06

OPERATION IS676

PROGRAMMINGROWUNITALARMLEVELS

TheRowUnitAlarmLevelsallowthe thresholds fortheseedratealarmstobeset.Thedefaultis50%orAverage.Iftheaveragepopulationdropsbelow50%foragivenrowaseedratealarmwillbegeneratedforthatrowunit.Thealarmthresholdcanbesetto70%,50%,�0%ordisabledforanyrow.

NOTE: When the alarm threshold is disabled for any row no seed rate alarm will be generated.

Thealarmthresholdscanbesetforthewholeplanter,anyplantersectionorindividualrows.

NOTE: A section is determined by a set of rows driven by one or more shafts, designated to a single shaft sensor.

STEP 1 Toenter‘‘ModeSelection’’,pressF6keyuntilthe‘‘ModeSelection’’screenappears.

STEP 2 Select‘‘SetupMode’’by turningtherotaryencoder knob or using the UP or DOWNarrowkeys.PresstheknoborENTERkeytodisplaythehighlighteditem.

STEP 3 Select‘‘RowUnitAlarmLevels’’byturningtheknoborusingtheUPorDOWNarrowkeys.PresstheknoborENTERkeytodisplaythehighlighteditem.

STEP 4 Tosetalarm thresholds forwholeplanter,select“WholePlanter”.Pressthekeynexttothedesiredthreshold.Whenthedesiredthresholdhasbeenspecifiedforallrowunits,presstheknoborENTERkey.

Tosetalarmthresholdsforall therowsinone section, select rear section or frontsection.Pressthekeynexttothedesiredthreshold.Whenthedesiredthresholdhasbeenspecified forall rowunits,press theknoborENTERkey.

Tosetalarmthresholdsforindividualrows,selectthedesiredrow.Pressthekeynexttothedesiredthreshold.Whenthedesiredthresholdhasbeenspecifiedforallrowunits,presstheknoborENTERkey.

STEP 5 Toreturnto“PlantingMode”pressthePLANTkey.

D0��406�3STEP 5 PresstheknoborENTERkeytoenterthecorrectvaluefor‘‘RowSpacing’’.Turntheknobtoincreaseordecreasethenumber.TheUParrowkeyisusedtoincreasethevalueoftheitembyoneandtheDOWNarrowkeyisusedtodecreasethevalueofthefieldbyone.TheLEFTarrowkeymultipliesthevalueoftheitemby�0andtheRIGHTarrowkeydividesthevalueoftheitemby�0.WhenthecorrectnumberhasbeenenteredpresstheknoborENTERkey.Theblackboxwilladvanceto‘‘UnitsofMeasure’’field.

NOTE: The narrowest row spacing the planter is equipped to plant should be entered for “Row Spacing”. Example: 12 Row 30" with Interplant, row spacing would be set to 15".

STEP 6 Select‘‘UnitsOfMeasure’’fieldbypressingtheknoborENTERkeyandadropdownmenuwillappear.Selecteither‘‘English’’or‘‘Metric’’byturningtheknoborusingtheUPorDOWNarrowkeys.PresstheknobortheENTERkey.TheblackboxwilladvancetoOK.

STEP 7 PresstheknoborENTERkey,whencorrectvaluesareentered.

STEP 8 Toreturnto“PlantingMode”pressthePLANTkey.

Rev.6/07

Page 41: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

4� 5/06

OPERATION IS676

NOTE: If the Distance Pulse Count number starts to count pulses with the tractor not moving, check radar distance sensor for vibration or other interference.

• Drive the tractor for 330 feet or �00meters.

•TheMonitorwillcountthenumberofpulsesanddisplaythem.

•Stopthetractorattheendpoint.

• Select “Tractor stopped. CalibrationDone”.

•PresstheknoborENTERkey.

NOTE: Repeat the above steps multiple times. Record and average the values. Use this average for the Distance Pulse Count number constant.

SPEEDSENSORCALIBRATION/PROGRAMMING

STEP 1 To enter the ‘‘Speed Sensor Calibration”mode,pressF6untilthe‘‘ModeSelection’’screenappears(IfApplicable).Select‘‘SetupMode’’andpresstherotaryencoderknoborENTERkey.PressF6toadvancetothe‘‘SpeedSensorCalibration’’screen.

TheDistancePulseCountisusedtorecordhowmanypulsesaregeneratedpermile/kilometer from the ground speed sensor.Themonitorwilldisplaythecurrentpulsespermile/kilometerusinga6digit,nodecimalplaceformat.

D0��40643

NOTE: A field calibration must be performed to establish the Distance Pulse Count number. Several factors can affect this value, such as wheel slip on the magnetic distance sensor. IT IS NOT UNCOMMON FOR THE SPEED ON THE MONITOR TO VARY SLIGHTLY FROM THE TRACTOR SPEEDOMETER. Adjusting the Distance Pulse Count in the monitor to make the speed agree with the tractor can cause serious errors in acre/hectare and population/spacing readings. Do field checks to verify populations and seed spacing.

• In field conditions, measure 330 feetor �00 meters, depending on the unit ofmeasurementselected.Placeamarkeratthestartpointandendpoint.

•Pullthetractoruptothestartingpoint. •Select“Tractorstopped.Startcalibration”. •PresstherotaryencoderknoborENTER

keytochangetheDistancePulseCountonthedisplayto0.

D0��00605

STEP 2 Select‘‘ChangeDistancePulseCount’’byturningtheknoborusingtheDOWNarrowkey.PresstheknoborENTERkey.

STEP 3 Toreturnto“PlantingMode”pressthePLANTkey.

NOTE: The Distance Pulse Count will vary from the above example.

Rev.9/07

Page 42: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

4� 5/06

OPERATION IS676

REPROGRAMMINGSPEEDSENSOR

Thissettingmustbespecifiedwhenthemonitorisfirstconfigured.Itwillbenecessarytoreprogramtouseanalternatespeedsensor.

NOTE: Speed sensors may not be changed while planting.

STEP 1 PresstheF6keyuntilthe‘‘ModeSelection’’screen appears. Select‘‘Setup Mode’’ byturningtherotaryencoderknoborusingtheUPorDOWNarrowkeys.PresstheknoborENTERkeytodisplaythehighlighteditem.

STEP 2 TurntheknoborusetheUPorDOWNarrowkeystochoose‘‘SensorSetup’’.PresstheknoborENTERkeytodisplaythehighlighteditem.

D0��406�4

NOTE: The Distance Pulse Count will vary from the above example.

STEP 3 Withthe“EnterPulseCount”fieldselectedpresstheknoborENTERkey.

STEP 4 ChangethePulseCounttothedesiredvalueusingtheUPorDOWNarrowkeysorturntheknobuntilthedesiredvalueisobtained.PresstheknoborENTERkey.

NOTE: The LEFT arrow key multiplies the value of the item by 10 and the RIGHT arrow key divides the value of the item by 10.

STEP 5 SelectOKbypressingtheknoborENTERkeytosavethenewcount.SelectCANCELtoretaintheoldvalueoftheDistancePulseCount.

STEP 6 PressPLANTkeytoreturntomainplantingscreen.

WHENTHECORRECTDISTANCEPULSECOUNTISKNOWN,CALIBRATIONISNOTNEEDEDANDTHEFOLLOWINGSTEPSMAYBEUSED.

STEP 1 To enter the “Speed Sensor Calibration”screen, press F6 key until the ‘‘ModeSelection’’ screen appears (If Applicable).Select‘‘SetupMode’’andpress therotaryencoderknoborENTERkey.PressF6keytoadvancetothe‘‘SpeedSensorCalibration’’screen.

STEP 2 Select ‘‘Change Distance Pulse’’ field byturningtheknoborusingtheUPorDOWN

D0��00605

RADAR TO MAGNETIC DISTANCE SENSOR

D0��4064�

Rev.9/07

Page 43: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

43 5/06

OPERATION IS676

D0��40639

Rev.6/06

STEP 3 TurntheknoborusetheUPorDOWNarrowkeystohighlight‘‘MagCoilPickup’’.PluginMagnetic Distance Sensor and press theINSTALL key. Press the knob or ENTERkeytosaveinformation.

D053�0609a

STEP 4 TurntheknoborusetheUPorDOWNarrowkeys to select ‘‘Select Speed Sensor’’andpress theknoborENTERkey. Press theknoborENTERkey to select the‘‘SpeedSensor’’ field and a drop down menu willappear. Turn the knob or use the UP orDOWNarrowkeystoselect‘‘CoilPick-Up’’andpresstheknoborENTERkeytomakeselection.TheblackboxwilladvancetoOKpresstheknoborENTERkeytosavetheinformation.

D053�0609

Page 44: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

44 5/06

OPERATION IS676

STEP 1 PresstheF6keyuntilthe‘‘ModeSelection’’screen appears. Select‘‘Setup Mode’’ byturningtherotaryencoderknoborusingtheUPorDOWNarrowkeys.PresstheknoborENTERkeytodisplaythehighlighteditem.

D0��406�4

MAGNETIC DISTANCE SENSOR TO RADAR

D0��4064�

STEP 2 Turn the knob or use the UP or DOWNarrowkeystochoose‘‘SensorSetup’’.Turnthe knob or use the UP or DOWN arrowkeystohighlight‘‘MagCoilPickup’’.Pressthe REMOVE key, a note will appear forconfirmationselectasappropriate.UnplugMagneticDistanceSensorandpresstheknoborENTERkeytosavetheinformation.

D0��40639

D06��060�

STEP 5 Unplugtheradarfromthetractor.

STEP 6 Press the PLANT key to return to mainplantingscreen.

NOTE: When switching between speed sensors, verify the distance pulse count is correct for the chosen sensor. There will be significant distance pulse count variation between radar and coil pick-up sensors.

NOTE: To prevent the configuration from being changed select CANCEL, then press the rotary encoder knob, ENTER key or ESC key.

Rev.�0/06

Page 45: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

45 5/06

OPERATION IS676

D0��40639

D0��40640

D0��40639

STEP 3 TurntheknoborusetheUPorDOWNarrowkeys toselect‘‘SelectSpeedSensor’’andpresstheknoborENTERkey.PresstheknoborENTERkeytoselectthe‘‘SpeedSensor’’fieldandadropdownmenuwillappear.Turnthe knob or use the UP or DOWN arrowkeystoselect‘‘Radar’’andpresstheknoborENTERkeytomakeselection.

STEP 5 Press the PLANT key to return to mainplantingscreen.

NOTE: When switching between speed sensors, verify the distance pulse count is correct for the chosen sensor. There will be significant distance pulse count variation between radar and magnetic distance sensors.

NOTE: To prevent the configuration from being changed select CANCEL, then press the knob, ENTER key or ESC key.

D053�0609

STEP 4 PluginRadarandtheblackboxwilladvancetoOK.PresstheknoborENTERkeytosavetheinformation.

Rev.�0/06

Page 46: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

46 5/06

OPERATION IS676

STEP 4 Thenoteshownbelowwillappear.SelectOKbyturningtheknoborusingtheUPorDOWNarrowkeys.PresstheknoborENTERkeytomaketheselection.

STEP 5 Turn the knob or use the UP or DOWNarrowkeystoselectthe‘‘FrontRowUnits’’fieldandpresstheknoborENTERkeytohighlight the field. Turn the knob or usetheUPorDOWNarrowkeystoobtainthedesirednumberofrows.WhenthecorrectvaluehasbeenenteredpresstheknoborENTERkey.TheblackboxwilladvancetotheOKkey.PresstheknoborENTERkeytosavetheinformation.

NOTE: To prevent the configuration from being changed select CANCEL, then press the knob, ENTER key or ESC key.D0���0674

D030�060�

ADDINGINTERPLANT®ROWS(IfRearRowsHavePreviouslyBeenProgrammed)

STEP 1 Press the F6 key until ‘‘Mode Selection’’screenappears.

STEP 2 Select‘‘SetupMode’’by turningtherotaryencoder knob or using the UP or DOWNarrowkeys.PresstheknoborENTERkeytodisplaythehighlighteditem.

D0��406�4

STEP 3 Select‘‘AddNewMuxbusSensors’’byturningtheknoborusingtheUPandDOWNarrowkeys.PresstheknoborENTERkeytodisplaythehighlighteditem.

D0��40633

Rev.�0/06

Page 47: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

47 5/06

OPERATION IS676

STEP 6 Thenoteshownbelowwillappear.SelectOKbyturningtheknoborusingtheUPorDOWNarrowkeys.PresstheknoborENTERkeytomaketheselection.

D030�0603

NOTE: To prevent the configuration from being changed select CANCEL, then press the knob, ENTER key or ESC key.

NOTE: Attempting to add rear rows while adding new muxbus sensors will cause the following note to appear.

D0���0675

D0���067�

STEP 8 WhenallsensorsarelearnedselectF�toendinstallation.Scrolldowntoverifythefrontrowsarelearned.SelectOKbypressingtheknoborENTERkey.

NOTE: ‘‘OK’’ will appear next to each sensor if no errors are detected.

D0��30604a

STEP 7 Thesensorconfigurationscreenwillappear.With [Auto Detect] highlighted selectINSTALL.Begintoinstallsensorsfromlefttoright.

Rev.6/06

Page 48: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

48 5/06

OPERATION IS676

ADDINGEVEN-ROWPACKAGE(IfFrontRowsHavePreviouslyBeenProgrammed)

STEP 1 Press the F6 key until ‘‘Mode Selection’’screenappears.

STEP 2 Select‘‘SetupMode’’by turningtherotaryencoder knob or using the UP or DOWNarrowkeys.PresstheknoborENTERkeytodisplaythehighlighteditem.

STEP 3 Select‘‘AddSingleInterplantRow’’byturningtheknoborusingtheUPandDOWNarrowkeys.PresstheknobortheENTERkeytodisplaythehighlighteditem.

D0��406�4

D0���06�00

STEP 10 Selectthe‘‘RowSpacing’’fieldbyturningtheknoborusingtheUPorDOWNarrowkeys.PresstheknoborENTERkeytohighlightfield. Adjust therowspacingtoInterplantspacing by turning the knob or using theUPorDOWNarrowkeys.PresstheknoborENTERkeytoenterthevalue.ThenturntheknoborusetheUPorDOWNarrowkeystoadvancetoOK.Presstheknoborenterkeytosaverowspacing.

NOTE: To prevent the configuration from being changed select CANCEL, then press the knob, ENTER key or ESC key.

STEP 11 Toreturnto“PlantingMode”pressthePLANTkey.

D0��406�5

STEP 9 Select ‘‘General Settings’’, by turning theknoborusingtheUPorDOWNarrowkeys.PresstheknoborENTERkeytomaketheselection.

Rev.�0/06

Page 49: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

49 5/06

OPERATION IS676

STEP 4 ToconfirmthefollowingnoteturntheknoborusetheUPorDOWNarrowkeystoselectOKandthenpresstheknoborENTERkeytoconfirm.IfthesingleInterplantrowisnotto be added select the CANCEL key andpresstheknoborENTERkeytocancelorpresstheESCkey.

D0���06�0�

D0���06�0�

STEP 5 To‘‘AddSingleInterplantRow’’thefollowingscreenwillappear.

If thesingle Interplant row is tobeaddedturntheknoborusetheUPorDOWNarrowkeystoselectOKandthenpresstheknoborENTERkeytoaddtheInterplantrow.IfthesingleInterplantrowisnottobeaddedselecttheCANCELkeyandpresstheknoborENTERkeytocancelorpresstheESCkey.

D0���0670

STEP 6 The ‘‘Sensor Configuration’’ screen willappear.Pluginthenewsensorthenscrolldowntohighlight“FrontRow�”byturningtheknoborusingtheUPorDOWNarrowkeys.Select INSTALL to learn the new sensor.PresstheknoborENTERkeytoreturntosetupmode.

STEP 7 Toreturnto“PlantingMode”pressthePLANTkey.

Rev.�0/06

Page 50: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

50 5/06

OPERATION IS676

Eitherselectthe‘‘PlantingMode’’byturningtheknoborusingtheUParrowkeyandpresstheknoborENTERkeyorpressF6toreturntothe‘‘PlantingMode’’.

ROW POPULATION • Press the ROW POP key to display row

population. Averageplanterpopulationwill beshowninthelowerL.H.cornerofthedisplay.

D0��40604

ENABLING/DISABLINGINTERPLANT®ROWS

ToEnableorDisableInterplant(a)presstheF6keyuntilthe‘‘ModeSelection’’screenappears,(b)turntherotaryencoderknoborusetheUPorDOWNarrowkeystohighlight‘‘Disable/EnableInterplant’’,(c)presstheknoborENTERkeyto‘‘Disable’’or‘‘Enable’’Interplant.Toverifyselection,therowspacingisdisplayedonthebottomofthescreen.

D030�0605a

D053�06�4

• PresstheSCANkeyandthemonitorwillscanthrougheachrowinascendingorderdisplayingtheaverageseedpopulationforeachrow.Afterallrowshavebeenscannedtheaveragepopulationisdisplayedandscanfunctionwillcontinuewiththefirstrearrow.

D0��4060�

Rev.6/06

Page 51: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

5� 5/06

OPERATION IS676

ROW SPACING • PresstheSPACINGkeytodisplayseedspacing

keys.SeedspacingwillappearinthebottomL.H.cornerofthedisplay.

• PresstheSCANkeyandthemonitorwillscanthrougheachrowinascendingorderdisplayingtheaverageseedspacing foreach row. ScanappearsintheL.H.cornertoindicatethedisplayisscanning.Afterallrowshavebeenscannedtheaveragepopulationisdisplayedandscanningwillcontinuewiththefirstrearrow.

• PresstheFREEZEkeytostopscanningandtheleftdisplayitemwillbefrozenonaparticularrow. “Frzn” appears to indicate the display isfrozen.ToresumescanpresstheSCANkey.

D0��40605

D0��4060�

• PresstheFREEZEkeytostopscanning,theleftdisplayitemwillbefrozenonaparticularrow.“Frzn”appearsinthelowerL.H.cornertoindicatethedisplayisfrozen.ToresumescanpresstheSCANkey.

EXAMPLE: When average row population is shown, R3 indicates rear row 3, F2 indicates front row 2, etc.

• WheneitherScanorFrznisdisplayedintheL.H.cornertheSECTIONandarrowkeysfunctionas follows: (a) SECTION or RIGHT arrow keyadvancestothefirstrowofthenextsection;(b)SECTIONorLEFTarrowkeyselectsthefirstrowoftheprevioussection,wrappingaroundtothefirstrowofthelastsectionwhenmovingpastthefirstsection;(c)UParrowkeymovesforwardtothenextrowoftheplanter,wrappingaroundtothefirstrowwhenmovingpastthelastrow;(d)DOWNarrowkeymovesbackwardtothepreviousrowoftheplanter,wrappingaroundtothelastrowoftheplanterwhenmovingpastthefirstrow.

• PresstheAVERAGEkeytodisplaytheaveragepopulationinthebottomL.H.corner.

• PresstheNORMALkeytodisplaythenormalscreenforplantingmode.

NOTE: If the rows are being scanned and the AVERAGE key is selected the scan function will stop.

D053�06�5

Rev.�0/06

Page 52: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

5� 5/06

OPERATION IS676

NOTE: The appropriate units of measure will be displayed (English or Metric).

• Press NORMAL to bring back the standardkeylabels.

• PresstheSHAFTkeytoviewtheaveragemetershaftRPM.ThevaluewillappearinthebottomR.H.cornerofthedisplay.

NOTE: Applicable to planters with shaft rotation sensors installed.

• PresstheSPEEDkeytoviewthegroundspeed.ThevaluewillappearinthebottomR.H.cornerofthedisplay.

D0��40607

D0��40608

SPEED/SHAFT ROTATION • PresstheOTHERkeytodisplayitemsavailable

todisplayinthebottomR.H.corner.

D0��40606

• Wheneither“Scan”or“Frzn”isdisplayedintheleft display item theSECTIONandarrowkeysfunction as follows: (a) SECTION and RIGHTarrowkeyadvancesto thefirst rowof thenextsection;(b)LEFTarrowkeyselectsthefirstrowoftheprevioussection,wrappingaroundtothefirstrowofthelastsectionwhenmovingpastthefirstsection;(c)UParrowkeymovesforwardtothenextrowoftheplanter,wrappingaroundtothefirstrowwhenmovingpastthelastrow;(d)DOWNarrowkeymovesbackwardtothepreviousrowoftheplanter,wrappingaroundtothelastrowoftheplanterwhenmovingpastthefirstrow.

• PresstheAVERAGEkeytodisplaytheaverageseedspacinginthebottomL.H.corner.

• PresstheNORMALkeytodisplaythemainplantingmode.

NOTE: If the rows are being scanned and the AVERAGE key is selected the scan function will stop.

D0��4060�

Rev.6/07

Page 53: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

53 5/06

OPERATION IS676

WARNINGSANDALARMS

1. Seed Rate Alarm-Aseedratealarmisactivatedwhenevertherowaverageseedpopulationdropsbelowthethresholdsetforthatrow.

The corresponding row on the bargraph startsflashingandthemonitoremitsaseriesofbeepsthatpersistuntil thealarm isclearor theACKbuttonispressed.‘‘SeedRateAlarm’’appearsintheupperleftcornerofthescreen.Thebargraphfortherowdropsdownbasedonthethresholdsetforthealarm.

EXAMPLE: If the threshold is 70% the lower two bargraph segments are shown. If the threshold is 50% or 10% the lowest bargraph segment is shown.

The status message associated with an alarmcontainsmoreinformationaboutthealarm.Toviewthe‘‘StatusMessage’’foraseedratealarm,presstheSTATUSkey.

Ifthesensorisdetectingnoseedflowitwilldisplaywhichrowisnotfunctioning.Thealarmmaybeindicatingamechanicalproblemthatisreducingtheseedfloworanelectricalproblemcausingtheseedcountstobeincorrect.

NOTE: The only way to remove an alarm is to find and correct the problem and correct it. Alarms are not reported for rows that seed rate alarm thresholds have been disabled.

NOTE: The percentage shown in the alarm message is the percentage at the time the alarm occured.

2. Section Not Planting-Whenthemonitordetectsanentiresectionnotplanting,themonitorwillemitthreebeepstoalerttheuser.Thebargraphfortheaffectedsectionflashesandisreducedtothelowestsegment.Analarmmessageisaddedtothelistof‘‘StatusMessages’’.PresstheSTATUSkeytoviewthealarmmessage.

NOTE: When it is known that a sensor or a group of sensors are faulty, F1 or F3 should be pressed. The monitor will no longer try to communicate with the sensor(s). In the planting mode the corresponding bargraphs will be grayed out in the main screen.

3. Seed Counting Sensors Not Communicating With Monitor - When the monitor detects acommunicationerrorbetweenthesensorandthemonitor,themonitorwillemittwobeepstoalerttheuser.Trytoreestablishcommunicationwithsensor(s)bypressingF�.Ifthemonitorisunabletoestablishcommunicationtheremaybe(a)afaultysensor,(b)apoorelectricalconnectionor(c)acutorpinchedwireharness.

D0���0687

D0���0659a

Ifmultiplesensorshavelostcontact,themessagewillindicatewhichsensorshavelostcontact.

Rev.�0/06

Page 54: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

54 5/06

OPERATION IS676

4. Seed Counting Sensors Too Dirty Warning -WhenpoweringontheKPMIII,eachoftheseedsensorswilldoaselfcheck.Ifaseedtubeistoodirty,themessage‘‘CleanOrReplaceSensorAsNecessary’’willbedisplayedand thebargraphforthatrowwillflash.TheLEDontheseedtubesensorwillnotflash.Thesensorwillnotfunctionuntiltheproblemiscorrected.

NOTE: After the alarms have been acknowledged and if the alarm condition is still present, the LCD screen will continue to display the alarm condition.

5. Wire Shorts-Whenawireisshortedanyoneofthemessagesshownbelowwillappear,statingwhichwiresareshorted.Theshortmustbelocatedandfixedtocontinueplanting.Cyclethepoweronthemonitortoclearthealarm.

D0���0684

D0���0683

D0���069�

D0���069�

D0���0685

NOTE: If the sensors are not faulty, F2 or F4 should be pressed and the message shown below will appear when the STATUS key is pressed.

NOTE: If a sensor has been ignored, the sensor configuration screen will display as shown below.

Rev.6/06

Page 55: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

55 5/06

OPERATION IS676

FIELDOPERATION

PresstheON/OFFkeytoturnthemonitorON.

If themonitor hasbeenconfigured, itwill enter thenormal plantingmodeandattempt to communicatewiththeseedsensors.

Ifthemonitordoesnotdetectanysensorsthemessageshownbelowwillappear.

NOTE: Selecting OK will reconfigure the monitor requiring all sensors to be re-learned. Selecting CANCEL will maintain the current configuration and the monitor will continue trying to communicate with the sensors.

D0��006�7

NOTE: Do not attempt planting before the ‘‘Wait For Calibration’’ message disappears. If planter is moving while sensors are calibrating alarms will be generated.

D0��00606

NOTE: If the monitor can communicate with the sensors the normal planting mode screen will be displayed.

D0���0689a

Rev.7/07

Page 56: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

56 5/06

OPERATION IS676

NOTE: Total area counter can never be disabled, but can be reset to zero (cleared).

• The asterisk next to the name of the areacounterindicatestheareacounterisenabledandaccumulatingarea.

EXAMPLE: In the photo shown above, 31.3K indicates the average seed population for the accumulated area is 31,300 seeds per unit area (acre/hectare). This number has been rounded off. The actual seed population ranges anywhere from 30,500 to 31,499 per unit area. The last column of numbers is the area accumulated (acre/hectare).

• TurntheknoborusetheUPorDOWNarrowkeystohighlightthedesired‘‘AreaCounter’’.

• PresstheENABLEorDISABLEkey.

NOTE: Up to four area counters can be enabled at one time (two area counters in addition to Total Area and Field Area). If four area counters are already enabled, disable one active area counter in order to enable a new area counter. To disable or enable area counters see next column.

NOTE: When a key is dimmed it does not perform any operation on the highlighted area counter.

ENABLE AREA COUNTEREachofthe‘‘DisabledAreaCounters’’maybeenabledup to a total of four ‘‘Area Counters’’. To Enable aDisabled‘‘AreaCounter’’:(a)highlightthedesired‘‘AreaCounter’’byturningtherotaryencoderknoborusingtheUPorDOWNarrowkeys;(b)presstheENABLEkeyorpresstheknoborENTERkeyandanasteriskwillappearnexttothe‘‘AreaCounter’’.TheEnabled‘‘AreaCounter’’startsaccumulatingarea.

DISABLE AREA COUNTEREachoftheEnabledAreaCountersmaybedisabled,withtheexceptionoftheTotalAreaCounter.Todisablean enabled area counter: (a) highlight that ‘‘AreaCounter’’;(b)presstheDISABLEkeyorpresstherotaryencoderknoborENTERkeyandtheasterisknexttothe‘‘AreaCounter’’willdisappear.The‘‘DisabledAreaCounter’’willnolongeraccumulatearea.

NOTE: Attempts to disable an Area Counter that is currently being displayed while planting will cause the following alarm. D0���06�7a

AREAMANAGEMENT

Thereare�0areacounters:TotalArea,FieldAreaandareacounters�through8.TheTotalAreaisalwaysactivebutmaybecleared. If it iscleared,theFieldAreaisalsocleared.FieldAreaandAreaCounters�through8maybeclearedindependentofeachother.Theymayalsobestartedorstoppedatanytime.Inaddition,thereisaLifetimeAreaCounter(locatedontheModeSelectionScreen)whichcannotbedisabledorclearedbytheuser.

Toenterthe‘‘AreaManagement’’screen,presstheF6keyuntilthe‘‘AreaManagement’’screenappears.D0���06�6a

Rev.�0/06

Page 57: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

57 5/06

OPERATION IS676

CLEAR AREA COUNTERTotalArea,FieldAreaandAreaCounters�through8canbecleared,whethertheyareEnabledorDisabled.Clearingthe‘‘TotalArea’’counterforcesthe‘‘FieldArea’’countertoalsobecleared.Clearinganyother‘‘AreaCounter’’includingthe‘‘FieldArea’’counterclearsonlythatcounter.

NOTE: Lifetime Area Counter can never be cleared or disabled.

ToclearanAreaCounter:(a)highlightthedesiredareacounter,byturningtherotaryencoderknoborusingtheUPorDOWNarrowkeys,(b)presstheCLEARkey,(c)therequestforconfirmationshownbelowwillappear,(d)turntheknoborusetheUPorDOWNarrowkeystoselectOKorCANCEL,(e)presstheknoborENTERkeytomakeselection.

To Clear All Area Counters except the ‘‘Total AreaCounter’’: (a)select theCLRALLkey;(b)arequestforconfirmationwillappear;(c)turntheknoborusetheUPorDOWNarrowkeys toselecteitherOKorCANCEL;(d)presstheknoborENTERkeytoconfirmselection.

NOTE: If the total area is highlighted and the CLEAR key is pressed the following request for confirmation will appear.

D0���06�6a

D0���06�8

D0��006��

Rev.6/07

Page 58: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

58 5/06

OPERATION IS676

Rev.6/06

NOTE: The abbreviation for the selected area counter numerical value will appear in the bottom R.H. corner of the screen. In the above photo ‘‘ACF’’ represents ‘‘Area Counter Field’’

STEP 4 PresstheknoborENTERkeytoselectOK.Theplantingscreenwillthenbedisplayed.Press NORMAL to display main plantingscreen.

D0��406�0

AREACOUNTERS STEP 3 Toselectthedesiredactive‘‘AreaCounter’’turntheknoborusetheUPorDOWNarrowstohighlightthedesired‘‘AreaCounter’’.

D0��4060�

D0��40603

D0��40609

STEP 2 PresstheSELECTkeytodisplaythelistoftheEnabledAreaCounters.

STEP 1 OnthemainplantingscreenpresstheAREAkey.

Page 59: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

59 5/06

OPERATION IS676

NOTE: If no radar unit is detected a warning will appear.

NOTE: If using acre count mode, area (acres or hectares) is accumulated in “Lifetime Area Counter”.

Acre Count Mode

STEP 1 PresstheF6keyuntilthe‘‘ModeSelection’’screen appears. Turn the rotary encoderknoborusetheUPorDOWNarrowkeystoselect‘‘AcreCountMode’’.PresstheknoborENTERkey.

ACRECOUNTMODE

Whenatractorisequippedwitharadardistancesensor,accumulatingareawithoutaplanterattachedispossible.Tworoutesareprovidedtoenteracrecountmode:(a)InstallationofanAcreCountSwitchKitor(b)entryintoAcreCountMode.

Acre Count Switch KitSTEP 1 WiththemonitorOFF,attachanAcreCount

SwitchKittotheMuxbusconnectorandthenturnmonitorONandadvancetoSTEP�.

D0��006�8

CLEARINGFIELDAREA

Toresetthecounter,displaythemainplantingscreenby pressing the F6 key until it appears. Press theAREAkeythenselect theCLEARkey,adialogboxwillappearrequestingconfirmationtoclear.SelectOKorCANCELkeybyturningtherotaryencoderknoborusingtheUPorDOWNarrowkeys.PresstheknoborENTERkeytoverifytheselection.

NOTE: Only the displayed Area Counter can be disabled.

D0���06�5

D0���06�5

Rev.�0/06

Page 60: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

60 5/06

OPERATION IS676

NOTE: DO NOT BEGIN ACCUMULATING AREA IF THE RADAR UNIT HAS NOT BEEN CALIBRATED. Always check the distance pulse count value immediately after entering acre count mode and before pressing start.

STEP 2 In the menu, ‘‘Units & Width’’ will behighlighted. Press the knob or ENTERkey.

STEP 3 Adropdownmenuwillappear.Selectthecorrectunitsofmeasure‘‘English’’or‘‘Metric’’byturningtheknoborusingtheUPorDOWNarrowkeys.PresstheknoborENTERkeytomake theselection. Theblackboxwilladvanceto‘‘ImplementWidth’’fieldshowingimplementwidthinfeet.

D0��006��

D0��006�9

STEP 4 PresstheknoborENTERkeytohighlightthefield. Turn theknoboruse theUPorDOWNarrowkeystoselectdesirednumberinfeet.Whendesirednumberisobtainedpress theknoborENTERkey. TheblackboxwilladvancetoOKkey.

NOTE: The implement width entered in acre count mode has no effect on planting mode settings.

STEP 5 PresstheknoborENTERkeywhendone.

NOTE: Tractor should be at a complete stop before starting.

STEP 6 TobeginaccumulatingareapresstheSTARTkey.

STEP 7 Tostopaccumulatingareaortomovetoadifferentlocation,presstheSTOPkey.

TherearetwocountersintheAcreCountMode(FieldAreaCounterandTotalAreaCounter).The‘‘FieldArea’’countercanbeclearedindependentofthe‘‘TotalArea’’counter.Clearingthe‘‘TotalArea’’countercausesthe‘‘FieldArea’’countertoalsobecleared.

•ToClearFieldArea.Highlight‘‘ClearFieldArea’’andpresstheknoborENTERkey.Anotewillappearverifyingthedecisiontoresetthefieldareatozero.SelectOKandpresstheknoborENTERkeytoclearthefieldtozero.SelectCancelandpresstheknobortheENTERkeytoretainthecurrentfieldvalue.

•To Clear Both Field Area AndTotal Area.Highlightthe‘‘ClearFieldArea&TotalArea’’andpresstheknoborENTERkey.Anotewillappeartoverifythedecisiontoresetthefieldareaandthetotalareatozero.SelectOKandpresstheknoborENTERkeytoclearthefieldtozero.SelectCANCELandpresstheknoborENTERkeytoretainthecurrentfieldvalue.

WithplanterreconnectedtomonitorreturntonormalplantscreenbypressingtheF6keyuntil the‘‘ModeSelection’’screenappears.Select‘‘PlantingMode’’byturningtheknoborusingtheUPorDOWNarrowkeys,presstheknoborENTERkey.

Rev.�0/06

Page 61: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

6� 5/06

OPERATION IS676

D0��4064�

D0���060�a

STEP 4 Highlightfaultysensor.PressREMOVEkeyandunplugsensor.PluginnewsensorandpressINSTALLkey.

Repeat above procedure for each faultysensorbeingreplaced.

NOTE: Highlighting a sensor and pressing VIEW gives additional information when troubleshooting a problem. If a faulty sensor has been ignored it may be highlighted in the list of sensors, press REVIVE. The monitor will try to communicate with the sensor. If successful, ‘‘OK’’ will appear next to the sensor.

REPLACINGFAULTYSENSOR(S)

To replace a single faulty sensor: (a) turn OFF themonitor,(b)replacethesensor,(c)turnmonitorON.Itwill then recognize thatasinglesensorhasbeenreplaced.

NOTE: Monitor will beep twice when the new senor(s) is learned.

Toreplacemorethanonefaultysensor:

STEP 1 Press F6 key until the ‘‘Mode Selection’’screenappears.

STEP 2 Select‘‘SetupMode’’byturningtheknoborpresstheUPorDOWNarrowkeys.PresstheknoborENTERkeytodisplaythehighlighteditem.

STEP 3 Select‘‘SensorSetup’’byturningtheknoborusingtheUPorDOWNarrowkeys.PresstheknoborENTERkeytodisplaythehighlighteditem.

STEP 5 PresstheknoborENTERkeytoreturnto‘‘SetupMode’’screen.

STEP 6 Toreturnto“PlantingMode”pressthePLANTkey.

Rev.7/07

Page 62: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

6� 5/06

OPERATION IS676CONTENTS LISTINGS IS676

Rev.7/07

MODEL 3200 Flex Econo-Fold® (Mechanical Seed Metering) 12 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�59

KPMIIIMonitorPackageRadarDistanceSensor 700-05�54

MODEL 3400 Twin-Line® (Mechanical Seed Metering) 12 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�57

KPMIIIMonitorPackageRadarDistanceSensor 700-05�58

Interplant®MonitorPackage 700-05��7

MODEL 3140 3 Pt. MountedStack Folding (Mechanical Seed Metering) 8 Row 12 Row 16 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�50 700-05�55 700-05�6�

KPMIIIMonitorPackageRadarDistanceSensor 700-05�5� 700-05�56 700-05�6�

MODEL 3110 3 Pt. MountedRigid Frame (Mechanical Seed Metering) 8 Row 12 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�44 700-05�46KPMIIIMonitorPackageRadarDistanceSensor 700-05�45 700-05�47

MODEL 3000 Pull Type (Mechanical Seed Metering) 4 Row 6 Row 8 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�4� 700-05�44 700-05�46KPMIIIMonitorPackageRadarDistanceSensor 700-05�43 700-05�45 700-05�47Interplant®MonitorPackage 700-05��4 700-05��5 700-05��6

MODEL 3500 Twin-Line® (Mechanical Seed Metering) 6 Row 8 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�44 700-05�46

KPMIIIMonitorPackageRadarDistanceSensor 700-05�45 700-05�47

Interplant®MonitorPackage 700-05��5 700-05��6

Page 63: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

63 Rev.6/06

CONTENTS LISTINGS IS676

MODEL 3600 Twin-Line® (Mechanical Seed Metering) 8 Row 12 Row 16 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�5� 700-05�59 700-05�63

KPMIIIMonitorPackageRadarDistanceSensor 700-05�49 700-05�54 700-05�64

Interplant®MonitorPackage 700-05��6 700-05��7 700-05��8

MODEL 3650 Twin-Line® (Mechanical Seed Metering) 12 Row 16 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�59 700-05�63

KPMIIIMonitorPackageRadarDistanceSensor 700-05�54 700-05�64

Interplant®MonitorPackage 700-05��7 700-05��8

MODEL 3700 Front Folding(Mechanical Seed Metering) 16 Row 24 Row 36 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�65 700-05�67 700-05�73

KPMIIIMonitorPackageRadarDistanceSensor 700-05�66 700-05�68 700-05�74

MODEL 3800 Forward Folding(Mechanical Seed Metering) 24 Row 32 Row 36 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�69 700-05�7� 700-05�75

KPMIIIMonitorPackageRadarDistanceSensor 700-05�70 700-05�7� 700-05�76

MODEL 3600TR Twin-Line® (Mechanical Seed Metering) 12 Row (24 Row) 16 Row (32 Row)

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�57 700-05�58

KPMIIIMonitorPackageRadarDistanceSensor 700-05�59 700-05�60

Rev.7/07

Page 64: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

64 Rev.6/06

CONTENTS LISTINGS IS676

MODEL 3110 3 Pt. MountedRigid Frame (EdgeVac® Seed Metering) 6 Row 8 Row KPMIIIMonitorPackageMagneticDistanceSensor 700-05�79 700-05�8�KPMIIIMonitorPackageRadarDistanceSensor 700-05�80 700-05�8�

MODEL 3200 Flex Econo-Fold® (EdgeVac® Seed Metering) 12 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�9�

KPMIIIMonitorPackageRadarDistanceSensor 700-05�87

MODEL 3400 Twin-Line® (EdgeVac® Seed Metering) 12 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�90

KPMIIIMonitorPackageRadarDistanceSensor 700-05�9�

Interplant®MonitorPackage 700-05�55

MODEL 3140 3 Pt. MountedStack Folding (EdgeVac® Seed Metering) 8 Row 12 Row 16 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�84 700-05�88 700-05�93

KPMIIIMonitorPackageRadarDistanceSensor 700-05�85 700-05�89 700-05�94

MODEL 3000 Pull Type (EdgeVac® Seed Metering) 4 Row 6 Row 8 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�77 700-05�79 700-05�8�KPMIIIMonitorPackageRadarDistanceSensor 700-05�78 700-05�80 700-05�8�Interplant®MonitorPackage 700-05�5� 700-05�53 700-05�54

Rev.7/07

Page 65: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

65 Rev.6/06

CONTENTS LISTINGS IS676

MODEL 3500 Twin-Line® (EdgeVac® Seed Metering) 6 Row 8 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�79 700-05�8�

KPMIIIMonitorPackageRadarDistanceSensor 700-05�80 700-05�8�

Interplant®MonitorPackage 700-05�53 700-05�54

MODEL 3600 Twin-Line® (EdgeVac® Seed Metering) 8 Row 12 Row 16 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�86 700-05�9� 700-05�95

KPMIIIMonitorPackageRadarDistanceSensor 700-05�83 700-05�87 700-05�96

Interplant®MonitorPackage 700-05�54 700-05�55 700-05�56

MODEL 3650 Twin-Line® (EdgeVac® Seed Metering) 12 Row 16 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�9� 700-05�95

KPMIIIMonitorPackageRadarDistanceSensor 700-05�87 700-05�96

Interplant®MonitorPackage 700-05�55 700-05�56

MODEL 3700 Front Folding(EdgeVac® Seed Metering) 16 Row 24 Row 36 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�97 700-05�99 700-05�05

KPMIIIMonitorPackageRadarDistanceSensor 700-05�98 700-05�00 700-05�06

MODEL 3800 Forward Folding(EdgeVac® Seed Metering) 24 Row 32 Row 36 Row

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�0� 700-05�03 700-05�07

KPMIIIMonitorPackageRadarDistanceSensor 700-05�0� 700-05�04 700-05�08

MODEL 3600TR Twin-Line® (EdgeVac® Seed Metering) 12 Row (24 Row) 16 Row (32 Row)

KPMIIIMonitorPackageMagneticDistanceSensor 700-05�6� 700-05�63

KPMIIIMonitorPackageRadarDistanceSensor 700-05�64 700-05�65

Rev.7/07

Page 66: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

66 Rev.6/06

CONTENTS LISTINGS IS676

4 ROW SIZES (Mechanical Seed Metering)KPM III Monitor Package, 4 Row - 700-05142(With Magnetic Distance Sensor)Model 3000(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A80�� PlanterHarnessW/DustCaps(4Row)(4)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 4 Row - 700-05143(With Radar Distance Sensor)Model 3000(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A80�� PlanterHarnessW/DustCaps(4Row)(4)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

6 ROW SIZES (Mechanical Seed Metering)KPM III Monitor Package, 6 Row - 700-05144(With Magnetic Distance Sensor)Models 3000, 3110 Rigid Frame And 3500(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A80�� PlanterHarnessW/DustCaps(6Row)(6)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 6 Row - 700-05145(With Radar Distance Sensor)Models 3000, 3110 Rigid Frame And 3500(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A80�� PlanterHarnessW/DustCaps(6Row)(6)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

4 ROW SIZES (EdgeVac® Seed Metering)KPM III Monitor Package, 4 Row - 700-05177(With Magnetic Distance Sensor)Model 3000(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A80�� PlanterHarnessW/DustCaps(4Row)(4)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 4 Row - 700-05178(With Radar Distance Sensor)Model 3000(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A80�� PlanterHarnessW/DustCaps(4Row)(4)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

6 ROW SIZES (EdgeVac® Seed Metering)KPM III Monitor Package, 6 Row - 700-05179(With Magnetic Distance Sensor)Models 3000, 3110 Rigid Frame And 3500(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A80�� PlanterHarnessW/DustCaps(6Row)(6)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 6 Row - 700-05180(With Radar Distance Sensor)Models 3000, 3110 Rigid Frame And 3500(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A80�� PlanterHarnessW/DustCaps(6Row)(6)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.7/07

Page 67: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

67 Rev.6/06

CONTENTS LISTINGS IS676

KPM III Monitor Package, 8 Row - 700-05149(With Radar Distance Sensor)Model 3600(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7850 PlanterHarnessW/DustCaps(8Row)(8)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 8 Row - 700-05147(With Radar Distance Sensor)Models 3110 Rigid Frame And 3500(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7850 PlanterHarnessW/DustCaps(8Row)(8)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 8 Row - 700-05151(With Radar Distance Sensor)Model 3140 Stack Folding(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7849 ExtensionHarnessW/Female Connectors,�5'(�)A80�� PlanterHarnessW/DustCaps(6Row)(�)A80�� PlanterHarnessW/DustCaps(4Row)(8)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

8 ROW SIZES (Mechanical Seed Metering)KPM III Monitor Package, 8 Row - 700-05152(With Magnetic Distance Sensor)Model 3600(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7850 PlanterHarnessW/DustCaps(8Row)(8)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 8 Row - 700-05146(With Magnetic Distance Sensor)Models 3000, 3110 Rigid Frame And 3500(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7850 PlanterHarnessW/DustCaps(8Row)(8)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 8 Row - 700-05150(With Magnetic Distance Sensor)Model 3140 Stack Folding(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7849 ExtensionHarnessW/Female Connectors,�5'(�)A80�� PlanterHarnessW/DustCaps(6Row)(�)A80�� PlanterHarnessW/DustCaps(4Row)(8)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.7/07

Page 68: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

68 Rev.6/06

CONTENTS LISTINGS IS676

KPM III Monitor Package, 8 Row - 700-05183(With Radar Distance Sensor)Model 3600(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7850 PlanterHarnessW/DustCaps(8Row)(8)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 8 Row - 700-05182(With Radar Distance Sensor)Models 3110 Rigid Frame And 3500(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7850 PlanterHarnessW/DustCaps(8Row)(8)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 8 Row - 700-05185(With Radar Distance Sensor)Model 3140 Stack Folding(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7849 ExtensionHarnessW/Female Connectors,�5'(�)A80�� PlanterHarnessW/DustCaps(6Row)(�)A80�� PlanterHarnessW/DustCaps(4Row)(8)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

8 ROW SIZES (EdgeVac® Seed Metering)KPM III Monitor Package, 8 Row - 700-05186(With Magnetic Distance Sensor)Model 3600(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7850 PlanterHarnessW/DustCaps(8Row)(8)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 8 Row - 700-05181(With Magnetic Distance Sensor)Models 3000, 3110 Rigid Frame And 3500(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7850 PlanterHarnessW/DustCaps(8Row)(8)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 8 Row - 700-05184(With Magnetic Distance Sensor)Model 3140 Stack Folding(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7849 ExtensionHarnessW/Female Connectors,�5'(�)A80�� PlanterHarnessW/DustCaps(6Row)(�)A80�� PlanterHarnessW/DustCaps(4Row)(8)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.7/07

Page 69: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

69 Rev.6/06

CONTENTS LISTINGS IS676

KPM III Monitor Package, 12 Row - 700-05155(With Magnetic Distance Sensor)Model 3140 Stack Folding(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7849 ExtensionHarnessW/Female Connectors,�5'(�)A7850 PlanterHarnessW/DustCaps(8Row)(�)A80�� PlanterHarnessW/DustCaps(4Row)(��)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

12 ROW SIZES (Mechanical Seed Metering)KPM III Monitor Package, 12 Row - 700-05159(With Magnetic Distance Sensor)Models 3200, 3600 And 3650(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (��Row)(��)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 12 Row - 700-05157(With Magnetic Distance Sensor)Model 3400(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (��Row)(��)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.7/07

Page 70: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

70 Rev.6/06

CONTENTS LISTINGS IS676

KPM III Monitor Package, 12 Row - 700-05154(With Radar Distance Sensor)Models 3200, 3600 And 3650(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(��Row)(��)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 12 Row - 700-05156(With Radar Distance Sensor)Model 3140 Stack Folding(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7849 ExtensionHarnessW/Female Connectors,�5'(�)A7850 PlanterHarnessW/DustCaps(8Row)(�)A80�� PlanterHarnessW/DustCaps(4Row)(��)A�090� SeedTubeW/Sensor(�)A7858 RadarGun(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A8�43 50Pc.Pkg.(D�5��)TieStraps(�)A80�6 RadarSensor

KPM III Monitor Package, 12 Row - 700-05158(With Radar Distance Sensor)Model 3400(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(��Row)(��)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.7/07

Page 71: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

7� Rev.6/06

CONTENTS LISTINGS IS676

KPM III Monitor Package, 12 Row - 700-05187(With Radar Distance Sensor)Models 3200, 3600 And 3650(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(��Row)(��)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 12 Row - 700-05189(With Radar Distance Sensor)Model 3140 Stack Folding(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7849 ExtensionHarnessW/Female Connectors,�5'(�)A7850 PlanterHarnessW/DustCaps(8Row)(�)A80�� PlanterHarnessW/DustCaps(4Row)(��)A��650 SeedTubeW/Sensor(�)A7858 RadarGun(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A8�43 50Pc.Pkg.(D�5��)TieStraps(�)A80�6 RadarSensor

KPM III Monitor Package, 12 Row - 700-05191(With Radar Distance Sensor)Model 3400(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(��Row)(��)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A80�6 RadarPipe/MountingBracketPackage(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

12 ROW SIZES (EdgeVac® Seed Metering)KPM III Monitor Package, 12 Row - 700-05192(With Magnetic Distance Sensor)Models 3200, 3600 And 3650(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (��Row)(��)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 12 Row - 700-05190(With Magnetic Distance Sensor)Model 3400(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (��Row)(��)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 12 Row - 700-05188(With Magnetic Distance Sensor)Model 3140 Stack Folding(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7849 ExtensionHarnessW/Female Connectors,�5'(�)A7850 PlanterHarnessW/DustCaps(8Row)(�)A80�� PlanterHarnessW/DustCaps(4Row)(��)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.7/07

Page 72: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

7� Rev.6/06

CONTENTS LISTINGS IS676KPM III Monitor Package, 16 Row - 700-05164(With Radar Distance Sensor)Models 3600 And 3650(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(�6Row)(�6)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 16 Row - 700-05166(With Radar Distance Sensor)Model 3700(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7850 PlanterHarnessW/DustCaps(8Row)(�6)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 16 Row - 700-05162(With Radar Distance Sensor)Model 3140 Stack Folding(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7849 ExtensionHarnessW/Female Connectors,�5'(�)A785� PlanterHarnessW/DustCaps(��Row)(�)A80�� PlanterHarnessW/DustCaps(4Row)(�6)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

16 ROW SIZES (Mechanical Seed Metering)KPM III Monitor Package, 16 Row - 700-05163(With Magnetic Distance Sensor)Models 3600 And 3650(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(�6Row)(�6)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 16 Row - 700-05165(With Magnetic Distance Sensor)Model 3700(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7850 PlanterHarnessW/DustCaps(8Row)(�6)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 16 Row - 700-05161(With Magnetic Distance Sensor)Model 3140 Stack Folding(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7849 ExtensionHarnessW/Female Connectors,�5'(�)A785� PlanterHarnessW/DustCaps(��Row)(�)A80�� PlanterHarnessW/DustCaps(4Row)(�6)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.7/07

Page 73: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

73 Rev.6/06

CONTENTS LISTINGS IS676KPM III Monitor Package, 16 Row - 700-05196(With Radar Distance Sensor)Models 3600 And 3650(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(�6Row)(�6)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 16 Row - 700-05198(With Radar Distance Sensor)Model 3700(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7850 PlanterHarnessW/DustCaps(8Row)(�6)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 16 Row - 700-05194(With Radar Distance Sensor)Model 3140 Stack Folding(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7849 ExtensionHarnessW/Female Connectors,�5'(�)A785� PlanterHarnessW/DustCaps(��Row)(�)A80�� PlanterHarnessW/DustCaps(4Row)(�6)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

16 ROW SIZES (EdgeVac® Seed Metering)KPM III Monitor Package, 16 Row - 700-05195(With Magnetic Distance Sensor)Models 3600 And 3650(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(�6Row)(�6)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 16 Row - 700-05197(With Magnetic Distance Sensor)Model 3700(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7850 PlanterHarnessW/DustCaps(8Row)(�6)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 16 Row - 700-05193(With Magnetic Distance Sensor)Model 3140 Stack Folding(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A7849 ExtensionHarnessW/Female Connectors,�5'(�)A785� PlanterHarnessW/DustCaps(��Row)(�)A80�� PlanterHarnessW/DustCaps(4Row)(�6)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.7/07

Page 74: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

74 Rev.6/06

CONTENTS LISTINGS IS676

24 ROW SIZES (Mechanical Seed Metering)KPM III Monitor Package, 24 Row - 700-05257(With Magnetic Distance Sensor)Model 3600TR 12 RN(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(��Row)(�4)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A8�35 DrillShaftRotationSensorKit(3)A8�43 50Pc.Pkg.(D�5��)TieStraps(�)A7853 JunctionY-HarnessW/DustCap(�)A��694 DrillShaftSensorMountingKit

KPM III Monitor Package, 24 Row - 700-05167(With Magnetic Distance Sensor)Model 3700(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(��Row)(�4)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 24 Row - 700-05169(With Magnetic Distance Sensor)Model 3800(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (��Row)(�)A80�� PlanterHarnessW/DustCaps(6Row)(�4)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A7849 ExtensionHarnessW/Female Connectors,�5'(4)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 24 Row - 700-05259(With Radar Distance Sensor)Model 3600TR 12 RN(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(��Row)(�4)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracket Package(3)A8�43 50Pc.Pkg.(D�5��)TieStraps(�)A7853 JunctionY-HarnessW/DustCap(�)A��694 DrillShaftSensorMountingKit

KPM III Monitor Package, 24 Row - 700-05168(With Radar Distance Sensor)Model 3700(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (��Row)(�4)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracket Package(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 24 Row - 700-05170(With Radar Distance Sensor)Model 3800(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (��Row)(�)A80�� PlanterHarnessW/DustCaps(6Row)(�4)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracket Package(�)A7849 ExtensionHarnessW/Female Connectors,�5'(4)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.7/07

Page 75: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

75 Rev.6/06

CONTENTS LISTINGS IS676

24 ROW SIZES (EdgeVac® Seed Metering)KPM III Monitor Package, 24 Row - 700-05262(With Magnetic Distance Sensor)Model 3600TR 12 RN(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(��Row)(�4)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A8�35 DrillShaftRotationSensorKit(3)A8�43 50Pc.Pkg.(D�5��)TieStraps(�)A7853 JunctionY-HarnessW/DustCap(�)A��694 DrillShaftSensorMountingKit

KPM III Monitor Package, 24 Row - 700-05199(With Magnetic Distance Sensor)Model 3700(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(��Row)(�4)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 24 Row - 700-05201(With Magnetic Distance Sensor)Model 3800(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (��Row)(�)A80�� PlanterHarnessW/DustCaps(6Row)(�4)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A7849 ExtensionHarnessW/Female Connectors,�5'(4)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 24 Row - 700-05264(With Radar Distance Sensor)Model 3600TR 12 RN(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(��Row)(�4)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracket Package(3)A8�43 50Pc.Pkg.(D�5��)TieStraps(�)A7853 JunctionY-HarnessW/DustCap(�)A��694 DrillShaftSensorMountingKit

KPM III Monitor Package, 24 Row - 700-05200(With Radar Distance Sensor)Model 3700(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (��Row)(�4)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracket Package(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 24 Row - 700-05202(With Radar Distance Sensor)Model 3800(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (��Row)(�)A80�� PlanterHarnessW/DustCaps(6Row)(�4)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracket Package(�)A7849 ExtensionHarnessW/Female Connectors,�5'(4)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.�0/06Rev.7/07

Page 76: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

76 Rev.6/06

CONTENTS LISTINGS IS676

32 ROW SIZE (Mechanical Seed Metering)KPM III Monitor Package, 32 Row - 700-05258(With Magnetic Distance Sensor)Model 3600TR 16 RN(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(�6Row)(3�)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A8�35 DrillShaftRotationSensorKit(3)A8�43 50Pc.Pkg.(D�5��)TieStraps(�)A7853 JunctionY-HarnessW/DustCap(�)A��694 DrillShaftSensorMountingKit

KPM III Monitor Package, 32 Row - 700-05171(With Magnetic Distance Sensor)Model 3800(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(�6Row)(�)A80�� PlanterHarnessW/DustCaps(6Row)(3�)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A7849 ExtensionHarnessW/Female Connectors,�5'(5)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 32 Row - 700-05260(With Radar Distance Sensor)Model 3600TR 16 RN(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(�6Row)(3�)A�090� SeedTubeW/Sensor(�)A7858 RadarGun(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(3)A8�43 50Pc.Pkg.(D�5��)TieStraps(�)A7853 JunctionY-HarnessW/DustCap(�)A��694 DrillShaftSensorMountingKit

KPM III Monitor Package, 32 Row - 700-05172(With Radar Distance Sensor)Model 3800(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(�6Row)(�)A80�� PlanterHarnessW/DustCaps(6Row)(3�)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(�)A7849 ExtensionHarnessW/Female Connectors,�5'(5)A8�43 50Pc.Pkg.(D�5��)TieStraps

32 ROW SIZE (EdgeVac® Seed Metering)KPM III Monitor Package, 32 Row - 700-05263(With Magnetic Distance Sensor)Model 3600TR 16 RN(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(�6Row)(3�)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A8�35 DrillShaftRotationSensorKit(3)A8�43 50Pc.Pkg.(D�5��)TieStraps(�)A7853 JunctionY-HarnessW/DustCap(�)A��694 DrillShaftSensorMountingKit

KPM III Monitor Package, 32 Row - 700-05203(With Magnetic Distance Sensor)Model 3800(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(�6Row)(�)A80�� PlanterHarnessW/DustCaps(6Row)(3�)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A7849 ExtensionHarnessW/Female Connectors,�5'(5)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 32 Row - 700-05265(With Radar Distance Sensor)Model 3600TR 16 RN(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(�6Row)(3�)A��650 SeedTubeW/Sensor(�)A7858 RadarGun(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(3)A8�43 50Pc.Pkg.(D�5��)TieStraps(�)A7853 JunctionY-HarnessW/DustCap(�)A��694 DrillShaftSensorMountingKit

KPM III Monitor Package, 32 Row - 700-05204(With Radar Distance Sensor)Model 3800(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps(�6Row)(�)A80�� PlanterHarnessW/DustCaps(6Row)(3�)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracketPackage(�)A7849 ExtensionHarnessW/Female Connectors,�5'(5)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.7/07

Page 77: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

77 Rev.6/06

CONTENTS LISTINGS IS676

36 ROW SIZES (Mechanical Seed Metering)KPM III Monitor Package, 36 Row - 700-05173(With Magnetic Distance Sensor)Model 3700(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A8050 PlanterHarnessW/DustCaps(�8Row)(36)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(4)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 36 Row - 700-05175(With Magnetic Distance Sensor)Model 3800(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (�6Row)(�)A80�� PlanterHarnessW/DustCaps(6Row)(36)A�090� SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A7849 ExtensionHarnessW/Female Connectors,�5'(5)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 36 Row - 700-05174(With Radar Distance Sensor)Model 3700(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A8050 PlanterHarnessW/DustCaps (�8Row)(36)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracket Package(4)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 36 Row - 700-05176(With Radar Distance Sensor)Model 3800(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (�6Row)(�)A80�� PlanterHarnessW/DustCaps(6Row)(36)A�090� SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracket Package(�)A7849 ExtensionHarnessW/Female Connectors,�5'(5)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.7/07

Page 78: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

78 Rev.6/06

CONTENTS LISTINGS IS676

36 ROW SIZES (EdgeVac® Seed Metering)KPM III Monitor Package, 36 Row - 700-05205(With Magnetic Distance Sensor)Model 3700(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A8050 PlanterHarnessW/DustCaps(�8Row)(36)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(4)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 36 Row - 700-05207(With Magnetic Distance Sensor)Model 3800(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (�6Row)(�)A80�� PlanterHarnessW/DustCaps(6Row)(36)A��650 SeedTubeW/Sensor(�)A6�47 SensorAndMountingPackage(�)A7859 MDSAdapter(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A7849 ExtensionHarnessW/Female Connectors,�5'(5)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 36 Row - 700-05206(With Radar Distance Sensor)Model 3700(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A8050 PlanterHarnessW/DustCaps (�8Row)(36)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracket Package(4)A8�43 50Pc.Pkg.(D�5��)TieStraps

KPM III Monitor Package, 36 Row - 700-05208(With Radar Distance Sensor)Model 3800(�)IS676 Instructions(�)IS673 QuickReferenceGuide(�)A��039 BacklitConsole(�)A785� PlanterHarnessW/DustCaps (�6Row)(�)A80�� PlanterHarnessW/DustCaps(6Row)(36)A��650 SeedTubeW/Sensor(�)A7858 RadarSensor(�)A��694 DrillShaftSensorMountingKit(�)A8�35 DrillShaftRotationSensorKit(�)A80�6 RadarPipe/MountingBracket Package(�)A7849 ExtensionHarnessW/Female Connectors,�5'(5)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.7/07

Page 79: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

79 Rev.6/06

CONTENTS LISTINGS IS676

INTERPLANT® MONITOR PACKAGES(EdgeVac® Seed Metering)Interplant® Monitor Package, 4 Row - 700-05252 Model 3000(�)A80�� PlanterHarnessW/DustCaps(4Row)(3)A��650 SeedTubeW/Sensor(�)A7853 JunctionY-HarnessW/DustCap(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Interplant® Monitor Package, 6 Row - 700-05253Models 3000 And 3500(�)A80�� PlanterHarnessW/DustCaps(4Row)(5)A��650 SeedTubeW/Sensor(�)A7853 JunctionY-HarnessW/DustCap(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Interplant® Monitor Package, 8 Row - 700-05254Models 3000, 3500 And 3600(�)A80�� PlanterHarnessW/DustCaps(6Row)(7)A��650 SeedTubeW/Sensor(�)A7853 JunctionY-HarnessW/DustCap(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Interplant® Monitor Package, 12 Row - 700-05255Models 3400, 3600 And 3650(�)A785� PlanterHarnessW/DustCaps(��Row)(��)A��650 SeedTubeW/Sensor(�)A7853 JunctionY-HarnessW/DustCap(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Interplant® Monitor Package, 16 Row - 700-05256Models 3600 And 3650(�5)A��650 SeedTubeW/Sensor(�)A7853 JunctionY-HarnessW/DustCap(�)A785� PlanterHarnessW/DustCaps(�6Row)(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

INTERPLANT® MONITOR PACKAGES(Mechanical Seed Metering)Interplant® Monitor Package, 4 Row - 700-05114 Model 3000(�)A80�� PlanterHarnessW/DustCaps(4Row)(3)A�090� SeedTubeW/Sensor(�)A7853 JunctionY-HarnessW/DustCap(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Interplant® Monitor Package, 6 Row - 700-05115Models 3000 And 3500(�)A80�� PlanterHarnessW/DustCaps(4Row)(5)A�090� SeedTubeW/Sensor(�)A7853 JunctionY-HarnessW/DustCap(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Interplant® Monitor Package, 8 Row - 700-05116Models 3000, 3500 And 3600(�)A80�� PlanterHarnessW/DustCaps(6Row)(7)A�090� SeedTubeW/Sensor(�)A7853 JunctionY-HarnessW/DustCap(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Interplant® Monitor Package, 12 Row - 700-05117Models 3400, 3600 And 3650(�)A785� PlanterHarnessW/DustCaps(��Row)(��)A�090� SeedTubeW/Sensor(�)A7853 JunctionY-HarnessW/DustCap(�)A8�43 50Pc.Pkg.(D�5��)TieStraps

Interplant® Monitor Package, 16 Row - 700-05118Models 3600 And 3650(�5)A�090� SeedTubeW/Sensor(�)A7853 JunctionY-HarnessW/DustCap(�)A785� PlanterHarnessW/DustCaps(�6Row)(3)A8�43 50Pc.Pkg.(D�5��)TieStraps

Rev.7/07

Page 80: KPM III ELECTRONIC SEED MONITOR … KPM III.pdf5/06 KPM III ELECTRONIC SEED MONITOR INSTALLATION INSTRUCTIONS IS676 Rev. 9/07 Throughout these instructions the symbol and/or the words

80 Rev.6/06

CONTENTS LISTINGS IS676

KINZE®, the KINZE® logo, Econo-Fold®, Twin-Line®, Interplant® and EdgeVac® are registered trademarks of KINZE Manufacturing, Inc.