68

Knox Storage Unit Design Specification

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Knox Storage Unit Design Specification
Page 3: Knox Storage Unit Design Specification

1 Contents .................................................................................................................................... 3

2 Scope ......................................................................................................................................... 6

3 Overview.................................................................................................................................... 6

3.1 Reference Document.................................................................................................... 6

4 Lightning Hardware System Overview ...................................................................................... 6

4.1 Lightning Key Features ................................................................................................. 6

4.2 Key Accessible Items .................................................................................................... 9

4.3 System Component Layout ........................................................................................ 10

4.4 Host Connection Block Diagram ................................................................................. 11

4.5 PCIe Block Diagram ..................................................................................................... 12

4.6 System I2C Topology .................................................................................................. 13

4.7 PCIe Clock Tree ........................................................................................................... 14

4.8 PCIe Sideband Signals ................................................................................................. 15

4.9 PCIe Reset Signals ....................................................................................................... 16

4.10 PCIe Lanes and Polarity Reversal ................................................................................ 16

4.11 SSD Carrier Power Control ......................................................................................... 16

5 Lightning PCIe Expansion Board .............................................................................................. 17

5.1 Block Diagram ............................................................................................................. 17

5.2 PEB Form Factor and Placement ................................................................................ 18

5.3 PCIe Switch IC ............................................................................................................. 19

5.4 Voltage Monitor ......................................................................................................... 20

5.5 Connectors ................................................................................................................. 20

5.6 Switch and Buttons..................................................................................................... 24

5.7 LEDs ............................................................................................................................ 24

5.8 PCB Stack-up ............................................................................................................... 25

6 Lightning PCIe Drive Plane Board ............................................................................................ 27

6.1 Block Diagram of PDPB ............................................................................................... 27

6.2 PDPB Form Factor and Placement ............................................................................. 28

6.3 Thermal Sensors ......................................................................................................... 29

6.4 Voltage Monitor ......................................................................................................... 30

6.5 Connectors ................................................................................................................. 31

6.6 LEDs ............................................................................................................................ 34

Page 4: Knox Storage Unit Design Specification

6.7 PCB Stack-up ............................................................................................................... 34

7 Lightning Power System .......................................................................................................... 35

7.1 PEB Power Budget ...................................................................................................... 35

7.2 System Level Power Budget ....................................................................................... 36

7.3 PEB Buck Converter Solutions .................................................................................... 36

7.4 Power Sequencing ...................................................................................................... 36

7.5 Power Button ............................................................................................................. 37

8 Mechanical of Tray and SSD Carrier ........................................................................................ 37

8.1 Changes for Tray Latches ........................................................................................... 37

8.2 SSD Connectors and Carriers ...................................................................................... 37

8.3 Single SSD Carrier (15 mm) ......................................................................................... 37

8.4 Single SSD Carrier (7 mm) ........................................................................................... 38

8.5 Dual M.2 Module Carrier ............................................................................................ 38

8.6 PCIe Expansion Board PCB Thickness ......................................................................... 40

8.7 Silk Screen .................................................................................................................. 40

8.8 PCB Color .................................................................................................................... 40

9 Baseboard Management Controller (BMC) ............................................................................. 41

9.1 Overview .................................................................................................................... 41

9.2 Host to Lightning BMC (Prioritized) ............................................................................ 41

9.3 Lightning BMC Support............................................................................................... 42

9.4 BMC Heartbeat ........................................................................................................... 42

9.5 BMC Watchdog Timer ................................................................................................ 42

9.6 BMC UART .................................................................................................................. 42

9.7 Debug Support ........................................................................................................... 43

9.8 BMC Firmware Update Approach .............................................................................. 43

9.9 BMC Reset .................................................................................................................. 43

9.10 Multiple Hosts (Stretch Goal) ..................................................................................... 43

9.11 BMC Sensor List .......................................................................................................... 43

9.12 Error Code display on Debug Card ............................................................................. 49

10 High Level System Consideration ............................................................................................ 49

10.1 Supported Servers ...................................................................................................... 49

10.2 PCIe Re-timer Card ..................................................................................................... 49

Page 5: Knox Storage Unit Design Specification

10.3 Supported SSDs .......................................................................................................... 50

10.4 PCIe Cables ................................................................................................................. 50

11 Thermal Design Requirements ................................................................................................ 51

11.1 Data Center Environmental Conditions ..................................................................... 51

11.2 Lightning operational conditions................................................................................ 52

11.3 Thermal kit requirements ........................................................................................... 53

12 Environmental Requirements and Reliability .......................................................................... 53

12.1 Environmental Requirements .................................................................................... 53

12.2 Vibration and Shock ................................................................................................... 54

12.3 Mean Time Between Failures (MTBF) Requirements ................................................ 54

12.4 Regulations ................................................................................................................. 54

13 Labels and Markings ................................................................................................................ 54

13.1 PCBA Labels and Markings ......................................................................................... 54

13.2 Chassis Labels and Markings ...................................................................................... 55

14 Prescribed Materials ............................................................................................................... 55

14.1 Sustainable Materials ................................................................................................. 55

14.2 Disallowed Components ............................................................................................. 55

14.3 Capacitors and Inductors ............................................................................................ 56

14.4 Component De-Rating ................................................................................................ 56

15 Appendix A: Interconnect Pin Definitions ............................................................................... 56

15.1 Pin definitions on PCIe Expansion Board .................................................................... 56

16 Appendix B: Error Code Definition .......................................................................................... 64

17 Revision History ....................................................................................................................... 67

Page 7: Knox Storage Unit Design Specification

Page 8: Knox Storage Unit Design Specification

Page 9: Knox Storage Unit Design Specification

Page 10: Knox Storage Unit Design Specification
Page 11: Knox Storage Unit Design Specification

SSDC 5 SSDC 6 SSDC 7 SSDC 8 SSDC 9

SSDC 0 SSDC 2 SSDC 3 SSDC 4

SSDC 11 SSDC 14SSDC 12SSDC 10 SSDC 13

Lightning PCIe Drive

Plane Boardwith

SSD Cartridges

LightningPCIe Expansion Board

FAN 1FAN 2FAN 3FAN 5FAN 6

Fan Control Board

FAN 4

SSDC 1

Power Transition Board

Page 12: Knox Storage Unit Design Specification

Host #4

Host #3

Host #2

Host #1

PCIe Expansion Board

Mini-SAS HD Cable

8 x8 or 15 x4 / 30 x2Down Stream

BMC

PCIe Switch

PCIe Re-timer

I2C Mux

4 x4 Up Stream

To HostsTo Local: PEB /

PDPB / FCB

...BMC

CPUCPU

Mini-SAS HD Cable

PCIeI2C

Mini-SAS HD CableMini-SAS HD Cable

A

B

C

D

USB

USB

USB Cable

USB Hub

Page 13: Knox Storage Unit Design Specification

Page 14: Knox Storage Unit Design Specification

PTB-1

PCIe Drive Plane Board -1

I2C_C (6)

Hot Swap Controller

PCIe Expansion Board -1

BMCAST2400

MiniSAS-HD A

MiniSAS-HD B

MiniSAS-HD C

MiniSAS-HD D

To PTB-2

Temp Sensor(x4)

EEPROM

Fan Controller

Power Monitor

FCB

LED Driver

MiniSAS-HD A

MiniSAS-HD B

MiniSAS-HD C

MiniSAS-HD D

I2C_1

I2C_2

I2C_3

I2C_4iso

iso

iso

iso I2C Buffer

I2C Buffer

I2C_B (7)

iso

iso

iso

isoI2C_11

I2C_12

I2C_13

I2C_14

I2C_A_D (5)

EEPROM

I2C Buffer

I2C Buffer

I2C_8

I2C_9

ClockGen

Temp Sensor(x4)

Voltage Monitor

EEPROM

Clock Buffer (x2)

I2C Bus Switch -1

I2C Bus Switch -2

Clock Buffer (x2)

SSD SMBus for slots:

3,4,8,9,12,13,14

SSD SMBus for slots:

0,1,2,5,6,7,10,11

... ...

I2C_10PM8536

TPM

RTC

Page 15: Knox Storage Unit Design Specification

From Host(s)

PCIe Drive Plane BoardPCIe Expansion Board

host refclk

host refclk

host refclk

host refclk

PM8536

PCIe Clock x8

SSDClock Buffer

1

x2 SSD

SSDx2

x2

SSDSSD

SSD

x2 SSD

SSDx2

x2x2 SSD

SSDx2

x2x2 SSD

SSDx2

x2

SSDSSD

SSDSSD

x2 SSD

SSDx2

x2x2 SSD

SSDx2

x2x2 SSD

SSDx2

x2

Clock Buffer

2

Clock Buffer

3

Clock Buffer

4

PCIe Clock x8

PCIe Clock x8

PCIe Clock x6

Clock Generator

PCIe Clock x1

PCIe Clock x1

PCIe Clock x1

PCIe Clock x1

PCIe Clock x1

Page 16: Knox Storage Unit Design Specification

IO0IO1IO2IO3IO4IO5IO6IO7IO8IO9

IO10IO11IO12IO13IO14IO15

I2C - GPIO Expander m = 1

AD0AD1AD2

SCLSDA

INT

I2C_SCLI2C_SDA

SHPC_INT#

ATNLED# 0PWREN 0PERST# 0

IFDET# 0

PM8536

SSD Slot 0

REFCLK_0REFCLK_1

PERST_0#PERST_1#

IFDET_N#PRSNT_N#DPEN_N#

SMCLKSMDAT

PCIe[3:0]

ACTLED

3V3_AUX12VGNDHot-Plug

Power Control

PEX_PRST#

From BMC

Blue /

Red LED

0 ohmRes

ATNLED# 1PWREN 1PERST# 1

IFDET# 1

ATNLED# 2PWREN 2PERST# 2

IFDET# 2

ATNLED# 3PWREN 3PERST# 3

IFDET# 3

PEB side PDPB side

Page 17: Knox Storage Unit Design Specification
Page 18: Knox Storage Unit Design Specification

Page 19: Knox Storage Unit Design Specification

Page 20: Knox Storage Unit Design Specification

Page 21: Knox Storage Unit Design Specification
Page 22: Knox Storage Unit Design Specification
Page 23: Knox Storage Unit Design Specification

Page 24: Knox Storage Unit Design Specification

Pin (CKT) Function

1 Low HEX character [0] least significant bit

2 Low HEX character [1]

3 Low HEX character [2]

4 Low HEX character [3] most significant bit

5 High HEX character [0] least significant bit

6 High HEX character [1]

7 High HEX character [2]

8 High HEX character [3] most significant bit

9 Serial Transmit

10 Serial Receive

11 Reset. Slide switch determines if its BMC or PCIe switch reset

12 Serial Port Select (1=Switch; 0=BMC)

13 GND

14 VCC (+5VDC)

Page 25: Knox Storage Unit Design Specification

Page 26: Knox Storage Unit Design Specification

Version

02

Glass/Copper Style Df(1G)

Cu oz Wiwynn Wiwynn

0.5 3.4 0.025

Top 0.5 oz+plating 2.1

3 3.9 0.009

L2 1 oz 1.3

4 3.9 0.009

L3 1 oz 1.3

16 4.2 0.009

L4 1 oz 1.3

4 3.8 0 0.009

L5 1 oz 1.3 0.0 0

16 0 0 4.2 0 0.009

L6 1 oz 1.3 0 0

4 0 0 3.9 0 0.009

L7 1 oz 1.3 0 0

3 0 0 3.9 0 0.009

Bottom 0.5 oz+plating 2.1 0 0

0.5 0 3.4 0 0.025

mil 63

mm 1.60

Note: 1. Unit is mil

2. The total thickness includes trace and solder mask

3. Min hole copper thickness is 1.0 mil

4. Min surface copper thickness 1.5 mil

5. Impedance Cpk requirement: >=1.33 (Report should be provided)

6. PCB supplier should design Delta-L coupon and provide measurement results meeting following criteria:

。 -0.65dB/inch at 4GHz for stripline routing

。 -0.69dB/inch at 4GHz for microstrip routing

Eason YS Chen

Layer Thickness

EE engineer

SI Engineer

Core

POWER

POWER

GND

Prepreg

Signal

Mask

Thickness requirement: 1.6 ± 10% mm

Prepreg

Signal

Core

Signal

Prepreg

Er

TU863+VLP / NPG171+VLP

Gold Finger(Y/N) Y

XXXXX

Board Number:

Project name:

Model Name:

Layer Count:

Date:

15105-1

Lightning_PMC

PEB

8 Layer

10/19/2016

Core

Mask

Signal

Prepreg

GND

Material:

Customer:

Leon Du

Imp Imp

Variation Variation

Type Type

Layers Layers

Width Imp Width Imp Width Space Imp Width Space Imp Width Space Imp Width Space Imp

S1 4.75(L2) 50.46 S1 5.38(L2) 6.62 85.36 4.13(L2) 9.37 101.06

P2 P2

S3 5(L2/L4) 49.19 S3 5.5(L2/L4) 7.5 84.85 4(L2/L4) 8 97.55

P4 P4

P5 P5

S6 5(L5/L7) 49.19 S6 5.5(L5/L7) 7.5 84.85 4(L5/L7) 8 97.55

P7 P7

S8 4.75(L7) 50.46 S8 5.38(L7) 6.62 85.36 4.13(L7) 9.37 101.06

MISC./I2C

reference layer

DP

1,3,6,8

Wiwynn

reference layer reference layer

reference layer reference layer

Bus Bus

Inner/Outer+/-5ohm

reference layer

Single Ended Type(mil)

50

SE

1,3,6,8

Wiwynn

reference layer

reference layer

reference layer

Differential Type(mil)

1,3,6,8

Wiwynn

reference layer

reference layer

100

Inner/Outer+/-10%

Clock/BMC DDR3

DP

85

Inner/Outer+/-10%

reference layer

PCIe/Clock/USB

Page 27: Knox Storage Unit Design Specification

Page 28: Knox Storage Unit Design Specification

Conn 1: Power and Signals Conn 2: Signals Conn 3: Signals

SSDC0

SSD Atten LED

SSDC1

SSDC2

SSDC3

SSDC4

SSDC5

SSDC6

SSDC7

SSDC8

SSDC9

SSDC10

SSDC11

SSDC12

SSDC13

SSDC14

To PTB then FCB

Re-driver as needed

SSD IDENT

PCIe Gen3

PCIe Gen3 PCIe

Gen3

Re-driver as needed

SSD Power Control

EE-PROM

Voltage Monitor

Temp. Sensor 1

Temp. Sensor 2

Temp. Sensor 3

Temp. Sensor 4

I2C_C, PWM, GPIOs

High Power Card Edge Connector

PCIe Reset

I2C_B

Page 29: Knox Storage Unit Design Specification
Page 30: Knox Storage Unit Design Specification
Page 31: Knox Storage Unit Design Specification
Page 32: Knox Storage Unit Design Specification
Page 33: Knox Storage Unit Design Specification
Page 34: Knox Storage Unit Design Specification

o o

• o o

o

Page 35: Knox Storage Unit Design Specification

Version

02

Imp

Variation

Type

Glass/Copper Style Df(1G) Layers

Cu oz Wiwynn Wiwynn

0.5 3.4 0.025 Width Imp Width Imp

Top 0.5 oz+plating 2.1 S1 6.75(L2) 50.7

4 3.8 0.009

L2 1 oz 1.3 P2

5 3.8 0.009

L3 1 oz 1.3 S3 6(L2/L4) 50.47

20 4.5 0.009

L4 2 oz 2.6 P4

11.4 4.2 0 0.009

L5 2 oz 2.6 0.0 0 P5

20 0 0 4.5 0 0.009

L6 1 oz 1.3 0 0 S6 6(L5/L7) 50.47

5 0 0 3.8 0 0.009

L7 1 oz 1.3 0 0 P7

4 0 0 3.8 0 0.009

Bottom 0.5 oz+plating 2.1 0 0 S8 6.75(L7) 50.7

0.5 0 3.4 0 0.025

mil 85

mm 2.16

Note: 1. Unit is mil

2. The total thickness includes trace and solder mask

3. Min hole copper thickness is 1.0 mil

4. Min surface copper thickness 1.5 mil

5. Impedance Cpk requirement: >=1.33 (Report should be provided)

6. PCB supplier should design Delta-L coupon and provide measurement results meeting following criteria:

。 -0.65dB/inch at 4GHz for stripline routing

。 -0.69dB/inch at 4GHz for microstrip routing

MISC./I2CEason YS Chen

Layer Thickness

EE engineer

SI Engineer

Core

POWER reference layer

POWER reference layer

GND

Bus

Prepreg

Signal

Mask

Thickness requirement: 2.16 ± 0.1 mm

Prepreg

Signal

Core

Signal

Prepreg

Er

TU863+VLP / NPG171+VLP

Gold Finger(Y/N)

Inner/Outer+/-5ohm

N

XXXXX

Board Number:

Project name:

Model Name:

Layer Count:

Date:

15669-1

Lightning_PMC

PDPB

8 Layer

10/19/2016

reference layer

Single Ended Type(mil)

50

Core

Mask

Signal

Prepreg

GND

SE

1,3,6,8

Wiwynn

reference layer

Material:

Customer:

Leon Du

Imp

Variation

Type

Layers

Width Space Imp Width Space Imp Width Space Imp Width Space Imp

S1 6.88(L2) 5.13 84.07 5(L2) 6 99.3

P2

S3 6.5(L2/L4) 7.5 84.49 4.5(L2/L4) 9 100.81

P4

P5

S6 6.5(L5/L7) 7.5 84.49 4.5(L5/L7) 9 100.81

P7

S8 6.88(L7) 5.13 84.07 5(L7) 6 99.3

reference layer

DP

1,3,6,8

Wiwynn

reference layer

reference layer

Bus

reference layer

reference layer

Differential Type(mil)

1,3,6,8

Wiwynn

reference layer

reference layer

100

Inner/Outer+/-10%

Clock

DP

85

Inner/Outer+/-10%

reference layer

PCIe/Clock

Page 36: Knox Storage Unit Design Specification

Major Device TDP max (W) Qty Utilization(%) Power(W)

PM8536 32.7 1 90% 29.43

AST2400 2.5 1 80% 2

Other Logics 5 1 80% 4

VR Losses 3.84 1 100% 3.84

44.04Power Budget for PEB

Item Qty in a 2U SystemPower Consumption

of Each Module

Total Power

Consumption

Measured

Power

Consumption

SSD 30 14 420 420

Drive Plane Board 2 9 18 16.2

PCIe Expansion Board 2 44.04 88.08 54.98

Fan Control Board 1 2 2 1.6

Fan Module 6 20 120 116.6

Total 609.38

Page 37: Knox Storage Unit Design Specification
Page 38: Knox Storage Unit Design Specification
Page 39: Knox Storage Unit Design Specification
Page 40: Knox Storage Unit Design Specification

3

Page 41: Knox Storage Unit Design Specification
Page 42: Knox Storage Unit Design Specification

Page 43: Knox Storage Unit Design Specification

Page 44: Knox Storage Unit Design Specification
Page 45: Knox Storage Unit Design Specification
Page 46: Knox Storage Unit Design Specification
Page 47: Knox Storage Unit Design Specification
Page 48: Knox Storage Unit Design Specification
Page 50: Knox Storage Unit Design Specification

PCIe Re-timer

PCIe x16 Golden Finger

PCIe Clock Buffer

Mini-SAS HD 1

Mini-SAS HD 2

Mini-SAS HD 3

Mini-SAS HD 4

I2C Mux

Voltage Regulators

12V

3.3VAUX

1.8V

1.0V

I2C

PCIe Reset

PCIe Clock

PCIex16

Mini-USB

Conn

USB

USB Hub

PCIe Clock

4 PCIe x4

3.3V

PCIe Clock

PCIeResetBuffer

Page 51: Knox Storage Unit Design Specification

• °

• °

Page 52: Knox Storage Unit Design Specification

Page 53: Knox Storage Unit Design Specification

Page 54: Knox Storage Unit Design Specification
Page 55: Knox Storage Unit Design Specification

Page 56: Knox Storage Unit Design Specification

GND A1 B1 GND PE_100M_CLK1_p CLK A2 B2 CLK PE_100M_CLK2_p

PE_100M_CLK1_n CLK A3 B3 CLK PE_100M_CLK2_n

Dri

ve 1

GND A4 B4 GND

TX A5 B5 PERST SSD10_PERST_N

TX A6 B6 GND

GND A7 B7 RX

GND A8 B8 RX

TX A9 B9 GND

TX A10 B10 GND

GND A11 B11 RX

GND A12 B12 RX

TX A13 B13 GND

TX A14 B14 GND

Page 57: Knox Storage Unit Design Specification

GND A15 B15 RX

GND A16 B16 RX

TX A17 B17 GND

TX A18 B18 GND

GND A19 B19 RX

For SSD 1 IFDET# A20 B20 RX For SSD 1 ATNLED A21 B21 GND For SSD 1 PWREN A22 B22 PWREN For SSD 10

D

rive

10

GND A23 B23 ATNLED For SSD 10

TX A24 B24 IFDET# For SSD 10

TX A25 B25 GND

GND A26 B26 RX

GND A27 B27 RX

TX A28 B28 GND

TX A29 B29 GND

GND A30 B30 RX

GND A31 B31 RX

TX A32 B32 GND

TX A33 B33 GND

GND A34 B34 RX

GND A35 B35 RX

TX A36 B36 GND

TX A37 B37 GND

GND A38 B38 RX

Dri

ve 0

GND A39 B39 RX

TX A40 B40 GND

TX A41 B41 GND

GND A42 B42 RX SSD1_PERST_N PERST A43 B43 RX SSD0_PERST_N PERST A44 B44 GND

Key Key

PWM_EXP_A Misc A45 B45 GND PCIe_Mated#_A Misc A46 B46 RX

GND A47 B47 RX

TX A48 B48 GND

TX A49 B49 GND

GND A50 B50 RX

GND A51 B51 RX

TX A52 B52 GND

TX A53 B53 GND

GND A54 B54 RX

Page 58: Knox Storage Unit Design Specification

GND A55 B55 RX

TX A56 B56 GND

TX A57 B57 IFDET# For SSD 5

GND A58 B58 ATNLED For SSD 5

For SSD 0 PWREN A59 B59 PWREN For SSD 5

For SSD 0

ATNLED A60 B60 GND For SSD 0

IFDET# A61 B61 RX

D

rive

5

GND A62 B62 RX

TX A63 B63 GND

TX A64 B64 GND

GND A65 B65 RX

GND A66 B66 RX

TX A67 B67 GND

TX A68 B68 GND

GND A69 B69 RX

GND A70 B70 RX

TX A71 B71 GND

TX A72 B72 GND

GND A73 B73 RX

GND A74 B74 RX

TX A75 B75 GND

TX A76 B76 CLK PE_100M_CLK3_p

GND A77 B77 CLK PE_100M_CLK3_n

PE_100M_CLK4_p CLK A78 B78 GND PE_100M_CLK4_n CLK A79 B79 I2C I2C_8_SCL

GND A80 B80 I2C I2C_8_SDA

I2C_B_SCL I2C A81 B81 GND I2C_B_SDA I2C A82 B82 PERST SSD5_PERST_N

GND A83 B83 Misc PEER_1A&2A_HB

I2C_9_SCL I2C A84 B84 Misc SELF_1A&2A_HB

I2C_9_SDA I2C A85 B85 Misc FCB_HW_REVISION

GND A86 B86 Misc DPB_HW_REVISION

I2C_C_SCL I2C A87 B87 Misc SELF_TRAY_PRESENT

I2C_C_SCL I2C A88 B88 Misc PEER_TRAY_PRESENT

GND A89 B89 GND

GND A90 B90 GND

GND A91 B91 GND

GND A92 B92 GND

GND A93 B93 GND

GND A94 B94 GND

P12V A95 B95 P12V

Page 59: Knox Storage Unit Design Specification

P12V A96 B96 P12V

P12V A97 B97 P12V

P12V A98 B98 P12V

P12V A99 B99 P12V

P12V A100 B100 P12V

Dri

ve 4

GND A1 B1 PERST SSD11_PERST_N

TX A2 B2 PERST SSD2_PERST_N

TX A3 B3 GND

GND A4 B4 RX

GND A5 B5 RX

TX A6 B6 GND

TX A7 B7 GND

GND A8 B8 RX

SSD3_PERST_N PERST A9 B9 RX For SSD 3 PWREN A10 B10 GND For SSD 3 ATNLED A11 B11 PESRT SSD12_PERST_N For SSD 3 IFDET# A12 B12 PWREN For SSD 12

Dri

ve 3

GND A13 B13 ATNLED For SSD 12

TX A14 B14 IFDET# For SSD 12

TX A15 B15 GND

GND A16 B16 RX

GND A17 B17 RX

TX A18 B18 GND

TX A19 B19 GND

GND A20 B20 RX

GND A21 B21 RX

TX A22 B22 GND

TX A23 B23 GND

GND A24 B24 RX

GND A25 B25 RX

TX A26 B26 GND

TX A27 B27 GND

GND A28 B28 RX

Dri

ve 7

GND A29 B29 RX

TX A30 B30 GND

TX A31 B31 GND

GND A32 B32 RX

Page 60: Knox Storage Unit Design Specification

GND A33 B33 RX

TX A34 B34 GND

TX A35 B35 GND

GND A36 B36 RX

GND A37 B37 RX

TX A38 B38 GND

TX A39 B39 GND

GND A40 B40 RX

GND A41 B41 RX

TX A42 B42 GND

TX A43 B43 PERST SSD7_PERST_N

GND A44 B44 PWREN For SSD 7

Key Key For SSD 7 ATNLED A45 B45 GND For SSD 7 IFDET# A46 B46 RX

Dri

ve 2

GND A47 B47 RX

TX A48 B48 GND

TX A49 B49 GND

GND A50 B50 RX

GND A51 B51 RX

TX A52 B52 GND

TX A53 B53 GND

GND A54 B54 RX

GND A55 B55 RX

TX A56 B56 GND

TX A57 B57 GND

GND A58 B58 RX

GND A59 B59 RX

TX A60 B60 GND

TX A61 B61 GND

GND A62 B62 RX

For SSD 2 IFDET# A63 B63 RX

For SSD 2 ATNLED A64 B64 GND For SSD 2 PWREN A65 B65 PWREN For SSD 11

Dri

ve 1

1

GND A66 B66 ATNLED For SSD 11

TX A67 B67 IFDET# For SSD 11

TX A68 B68 GND

GND A69 B69 RX

GND A70 B70 RX

TX A71 B71 GND

Page 61: Knox Storage Unit Design Specification

TX A72 B72 GND

GND A73 B73 RX

GND A74 B74 RX

TX A75 B75 GND

TX A76 B76 GND

GND A77 B77 RX

GND A78 B78 RX

TX A79 B79 GND

TX A80 B80 GND

GND A81 B81 RX

Dri

ve 6

GND A82 B82 RX

TX A83 B83 GND

TX A84 B84 GND

GND A85 B85 RX

GND A86 B86 RX

TX A87 B87 GND

TX A88 B88 GND

GND A89 B89 RX

GND A90 B90 RX

TX A91 B91 GND

TX A92 B92 GND

GND A93 B93 RX

GND A94 B94 RX

TX A95 B95 GND

TX A96 B96 GND

GND A97 B97 RX

For SSD 6 IFDET# A98 B98 RX

For SSD 6 ATNLED A99 B99 GND For SSD 6 PWREN A100 B100 PERST SSD6_PERST_N

Dri

ve 1

4

GND A1 B1 ATNLED For SSD 14

TX A2 B2 PWREN For SSD 14

TX A3 B3 GND

GND A4 B4 RX

GND A5 B5 RX

TX A6 B6 GND

TX A7 B7 GND

GND A8 B8 RX

Page 62: Knox Storage Unit Design Specification

GND A9 B9 RX

TX A10 B10 GND

TX A11 B11 GND

GND A12 B12 RX

GND A13 B13 RX

TX A14 B14 GND

TX A15 B15 GND

GND A16 B16 RX

For SSD 14 IFDET# A17 B17 RX

For SSD 9 PWREN A18 B18 GND

For SSD 9 ATNLED A19 B19 GND

For SSD 9 IFDET# A20 B20 RX

Dri

ve 1

3

GND A21 B21 RX

TX A22 B22 GND

TX A23 B23 GND

GND A24 B24 RX

GND A25 B25 RX

TX A26 B26 GND

TX A27 B27 GND

GND A28 B28 RX

GND A29 B29 RX

TX A30 B30 GND

TX A31 B31 GND

GND A32 B32 RX

GND A33 B33 RX

TX A34 B34 GND

TX A35 B35 GND

GND A36 B36 RX

Dri

ve 9

GND A37 B37 RX

TX A38 B38 GND

TX A39 B39 GND

GND A40 B40 RX

GND A41 B41 RX

TX A42 B42 GND

TX A43 B43 PERST SSD14_PERST_N

GND A44 B44 PERST SSD4_PERST_N

Key Key

SSD9_PERST_N PERST A45 B45 GND

SSD13_PERST_N PERST A46 B46 RX

GND A47 B47 RX

Page 63: Knox Storage Unit Design Specification

TX A48 B48 GND

TX A49 B49 GND

GND A50 B50 RX

GND A51 B51 RX

TX A52 B52 GND

TX A53 B53 IFDET# For SSD 4

GND A54 B54 ATNLED For SSD 4

For SSD 13 PWREN A55 B55 PWREN For SSD 4

For SSD 13 ATNLED A56 B56 GND

For SSD 13 IFDET# A57 B57 RX

GND A58 B58 RX

Dri

ve 8

TX A59 B59 GND

TX A60 B60 GND

GND A61 B61 RX

GND A62 B62 RX

TX A63 B63 GND

TX A64 B64 GND

GND A65 B65 RX

GND A66 B66 RX

TX A67 B67 GND

TX A68 B68 GND

GND A69 B69 RX

GND A70 B70 RX

TX A71 B71 GND

TX A72 B72 GND

GND A73 B73 RX

GND A74 B74 RX

Dri

ve 1

2

TX A75 B75 GND

TX A76 B76 GND

GND A77 B77 RX

GND A78 B78 RX

TX A79 B79 GND

TX A80 B80 GND

GND A81 B81 RX

GND A82 B82 RX

TX A83 B83 GND

TX A84 B84 GND

GND A85 B85 RX

GND A86 B86 RX

TX A87 B87 GND

TX A88 B88 IFDET# For SSD 8

Page 64: Knox Storage Unit Design Specification

GND A89 B89 ATNLED For SSD 8

GND A90 B90 PWREN For SSD 8

Dri

ve 4

TX A91 B91 PERST SSD8_PERST_N

TX A92 B92 GND

GND A93 B93 RX

GND A94 B94 RX

TX A95 B95 GND

TX A96 B96 GND

GND A97 B97 RX

Tray_ID Misc A98 B98 RX

SD_LATCH_RELEASE Misc A99 B99 GND

PCIe_Mated#_B Misc A100 B100 Misc I2C_MUX_RESET_PEB

Page 65: Knox Storage Unit Design Specification
Page 66: Knox Storage Unit Design Specification
Page 67: Knox Storage Unit Design Specification
Page 68: Knox Storage Unit Design Specification