Knockout Tile © 2019 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. KOB-01-MAN REV 1.30 4 1 3 5 2 6 7 8 7 NO. DESCRIPTION 1 ASSY, PEDESTAL 1 2 SCREW, LAG, HEX, 5/16, 4.0L 3 TILE REPLACEMENT FLASHING, S 4 TILE REPLACEMENT FLASHING, FLAT 5 TILE REPLACEMENT FLASHING, W 6 L-1X5, BLACK 7 WASHER, BONDED 8 NUT, FLANGE 5/16-18 SST WEIGHT: 2.754 LBS SHEET 1 OF 1 SIZE SCALE:1:1 DO NOT SCALE DRAWING A KNOCKOUT TILE

Knockout Tile - IronRidgefiles.ironridge.com/pitched-roof-mounting/resources/...5 TILE REPLACEMENT FLASHING, W 6 L-1X5, BLACK 7 WASHER, BONDED 8 NUT, FLANGE 5/16-18 SST WEIGHT: 2.754

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Knockout Tile - IronRidgefiles.ironridge.com/pitched-roof-mounting/resources/...5 TILE REPLACEMENT FLASHING, W 6 L-1X5, BLACK 7 WASHER, BONDED 8 NUT, FLANGE 5/16-18 SST WEIGHT: 2.754

Knockout Tile

© 2019 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. KOB-01-MAN REV 1.30

4

1

3

5

2

678

7

NO. DESCRIPTION1 ASSY, PEDESTAL 12 SCREW, LAG, HEX, 5/16, 4.0L3 TILE REPLACEMENT FLASHING, S4 TILE REPLACEMENT FLASHING, FLAT5 TILE REPLACEMENT FLASHING, W6 L-1X5, BLACK7 WASHER, BONDED8 NUT, FLANGE 5/16-18 SST WEIGHT: 2.754 LBS SHEET 1 OF 1

SIZE

SCALE:1:1

DO NOT SCALE DRAWINGA

KNOCKOUT TILE

Page 2: Knockout Tile - IronRidgefiles.ironridge.com/pitched-roof-mounting/resources/...5 TILE REPLACEMENT FLASHING, W 6 L-1X5, BLACK 7 WASHER, BONDED 8 NUT, FLANGE 5/16-18 SST WEIGHT: 2.754

Insert Tile Replacement Flashing, lower onto base and apply pressure over the threaded post until it dimples the flashing.

Place L-Foot over top of dimple and tap with hammer to punch the threaded posted through the flashing.Ensure punched pieces of flashing are cleared away.

© 2019 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. KOB-01-MAN REV 1.30

Installation

Tools Required: Tape measure, chalk, approved sealant, hammer, and driver with 1/4” bit and 1/2” hex socket

1

Remove tile and mark rafter. Use base as guide to drill 1/4” pilot hole and fill with roofing manufacturer’s approved sealant.

Structural CertificationDesigned and Certified for Compliance with the International Building Code & ASCE/SEI-7.Water Seal RatingsWater Sealing Tested to UL 441 Section 27 “Rain Test” and TAS 100(A)-95 “Wind Driven Rain Test” by Intertek. Ratings applicable for concrete tile roofs having slopes between 2:12 and 12:12. Tested and evaluated without sealant. Any roofing manufacturer approved sealant is allowed.UL 2703Conforms to UL 2703 (2015) Mechanical and Bonding Requirements. See IronRidge Flush Mount Installation Manual for full ratings.

Insert lag with bonded washer through base intopilot hole and fully seat. Base can be installed in any orientation relative to rafter. Seal or flash base as needed. If deck level flashing is required, approved flashing methods include user-supplied, adhesive-backed, flexible flashing.

Form flashing as needed to sit flush with surrounding tiles. Position L-Foot in desired orientation. L-foot can be installed facing any direction. Torque Hardware to 132 in-lbs (11 ft-lbs).

Attach rail to either side of L-Foot with 3/8” bonding hardware. Ensure L-Foot does not extend above rail. Torque hardware to 250 in-lbs (21 ft-lbs).

2

3 4

5 6

Rafter

Dimple

Tap With Hammer

Torque to 132 in-lbs

Torque to 250 in-lbs

Orient Base to desired position Tighten until fully seated