Upload
others
View
6
Download
0
Embed Size (px)
Citation preview
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEET
DRAWN
CHECKED
APPROVED
KOHLER, WISCONSIN 53044THIS DRAWING IN DESIGN AND DETAIL IS KOHLERCO. PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTSOF DESIGN OR INVENTION ARE RESERVED.
SURFACE FINISH
MAX.
UNLESS OTHERWISE SPECIFIED: ALL DIMENSIONS IN MILLIMETERS GENERAL TOLERANCES: X.XX �#� 0.25 X.X �#� 1.0 X �#� 1.5 ANGLES �#� 0�$�30'
734
28.9
[]
415 16.4[ ]
175
6.9
[]
522.1[ ]
255 10.0[ ](4) MTG HOLES10 0.4[ ]
MOUNTING HOLES
590
23.2
[]
54 2.1
[]
DIMENSION PRINT0.40 1 of 3
ADV-9046 D
DO NOT SCALE. REFERENCE THE MODEL FOR ALL UNSPECIFIED DIMENSIONS
THIRD ANGLE PROJECTION
APPROVALS DATE
BTW 11-15-17
BTW 11-15-17
MTL 11-15-17
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY
- 11-15-17 NEW DRAWING [CT179697] BTW
100-200AMODEL RXT
SERVICE ENTRANCETYPE 3R ENCLOSURES
DIMENSION IN [ ] ARE INCHES. FINISH: ANSI 69 GRAY REFER TO OPERATOR'S MANUAL PRIOR TOINSTALLATION AND OPERATION OF UNIT. 100 AMP APPROXIMATE WEIGHT 10Kg (22 LBS) 200 AMP APPROXIMATE WEIGHT 12Kg (26 LBS)
FRONT VIEW
TOP VIEW
BACK VIEW
100ACOVER NOT SHOWN
KNOCKOUT FORAUXILIARY BREAKER KIT
(OPTION)SAME FOR BOTH 100 & 200 AMP UNITS
200ACOVER NOT SHOWN
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEET
DRAWN
CHECKED
APPROVED
KOHLER, WISCONSIN 53044THIS DRAWING IN DESIGN AND DETAIL IS KOHLERCO. PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTSOF DESIGN OR INVENTION ARE RESERVED.
SURFACE FINISH
MAX.
UNLESS OTHERWISE SPECIFIED: ALL DIMENSIONS IN MILLIMETERS GENERAL TOLERANCES: X.XX �#� 0.25 X.X �#� 1.0 X �#� 1.5 ANGLES �#� 0�$�30'
GROUND
152
6.0
[]
NEUTRAL
225
8.9
[]
LOAD
215
8.5
[]
EMERGENCY
225
8.9
[]
NORMAL
248
9.8
[]
LOAD
182
7.2
[]
EMERGENCY
216
8.5
[]
DIMENSION PRINT0.40 2 of 3
ADV-9046 D
DO NOT SCALE. REFERENCE THE MODEL FOR ALL UNSPECIFIED DIMENSIONS
THIRD ANGLE PROJECTION
APPROVALS DATE
BTW 11-15-17
BTW 11-15-17
MTL 11-15-17
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY
- 11-15-17 NEW DRAWING [CT179697] BTW
STATUSINDICATOR
(OPTIONAL)
TRANSFERSWITCH
100A UTILITYDISCONNECT
NEUTRALBONDINGJUMPER
AUXILIARYBREAKER KIT(OPTIONAL)
100AINNER PANEL & COVER
REMOVED TO SHOW DETAILS
GROUND
NEUTRAL
AUXILIARY CONTACTS(OPTIONAL)
PADLOCK HASP
SECTION B-B
PCB, ATSINTERFACE
(OPTIONAL LOAD SHEDBOARD SHOWN)
OUTERCOVER
INNERPANEL
GROUND
NEUTRAL
ALTERNATE CONTACTOR VIEW
AUXILIARYCONTACTS
(OPTIONAL)
SCREW TYPE TERMINALS FOR EXTERNAL POWER CONNECTION
SWITCHRATING(AMPS)
RANGE OF AL-CU WIRE SIZES
NORMAL (PER PHASE)EMERGENCY / LOAD
(PER PHASE)NEUTRAL GROUND
100 (1) #12-2/0 AWG (1) #14-1/0 AWG(5) #12-250 KCMIL (Cu)
OR(5) #10-250 KCMIL (Al)
(9) #14-6 AWG(4) #14-1/0 AWG
150-200 (1) #4-300 KCMIL (1) #6-250 KCMIL(5) #12-250 KCMIL (Cu)
OR(5) #10-250 KCMIL (Al)
(9) #14-6 AWG(4) #14-1/0 AWG
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEET
DRAWN
CHECKED
APPROVED
KOHLER, WISCONSIN 53044THIS DRAWING IN DESIGN AND DETAIL IS KOHLERCO. PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTSOF DESIGN OR INVENTION ARE RESERVED.
SURFACE FINISH
MAX.
UNLESS OTHERWISE SPECIFIED: ALL DIMENSIONS IN MILLIMETERS GENERAL TOLERANCES: X.XX �#� 0.25 X.X �#� 1.0 X �#� 1.5 ANGLES �#� 0�$�30'
LOAD
178
7.0
[]
EMERGENCY
218
8.6
[]
NORMAL
183
7.2
[]
GROUND
152
6.0
[]
NEUTRAL
225
8.9
[]
LOAD
178
7.0
[]
EMERGENCY
212
8.3
[]
DIMENSION PRINT0.40 3 of 3
ADV-9046 D
DO NOT SCALE. REFERENCE THE MODEL FOR ALL UNSPECIFIED DIMENSIONS
THIRD ANGLE PROJECTION
APPROVALS DATE
BTW 11-15-17
BTW 11-15-17
MTL 11-15-17
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY
- 11-15-17 NEW DRAWING [CT179697] BTW
ALTERNATE CONTACTOR VIEW
AUXILIARYCONTACTS
(OPTIONAL)
GROUND
TRANSFERSWITCH
200A UTILITYDISCONNECT
STATUSINDICATOR
(OPTIONAL)
NEUTRALBONDINGJUMPER
NEUTRAL
AUXILIARYBREAKER KIT(OPTIONAL)
150-200AINNER PANEL & COVER
REMOVED TO SHOW DETAILS
AUXILIARY CONTACTS(OPTIONAL)
PADLOCK HASP
SECTION B-B
PCB, ATSINTERFACE
(OPTIONAL LOAD SHEDBOARD SHOWN)
NEUTRAL
COVEROUTER
INNERPANEL
GROUND