7
INSTALLATION INSTRUCTIONS Kitchen Faucet with Remote Valve 1104263_2_B 1 of 7 Questions? Problems? For additional assistance, please contact Kallista’s Customer Service Department at 1-888-4KALLISTA (1-888-452-5547) or FAX 1-888-272-3094. P25201

Kitchen Faucet with Remote Valveresources.kohler.com/interiors/kallista/pdf/1104263_2.pdf · components from this faucet. This faucet contains back-siphonage protection. NOTICe: Due

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Kitchen Faucet with Remote Valveresources.kohler.com/interiors/kallista/pdf/1104263_2.pdf · components from this faucet. This faucet contains back-siphonage protection. NOTICe: Due

INSTALLATION INSTRUCTIONS

Kitchen Faucet with Remote Valve

1104263_2_B1 of 7

Questions? Problems? For additional assistance, please contact Kallista’s CustomerService Department at 1-888-4KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.

P25201

Page 2: Kitchen Faucet with Remote Valveresources.kohler.com/interiors/kallista/pdf/1104263_2.pdf · components from this faucet. This faucet contains back-siphonage protection. NOTICe: Due

INSTALLATION INSTRUCTIONS

Kitchen Faucet with Remote Valve

1104263_2_B2 of 7

Questions? Problems? For additional assistance, please contact Kallista’s CustomerService Department at 1-888-4KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.

ThANk YOU FOR ChOOSINg kALLISTA

We appreciate your commitment to Kallista quality products. Please take a moment to review this manual before you install your Kallista product. If you encounter any installation or performance problems, please do not hesitate to contact us at the phone number listed at the bottom of the page.

BeFORe YOU BegIN

CAUTION: Risk of fresh water contamination. To prevent water contamination, do not remove any components from this faucet. This faucet contains back-siphonage protection.

NOTICe: Due to the non-standard 2″ (5.1 cm) diameter of the remote valve, the remote valve cannot be mounted through a standard 1-3/8″ (3.5 cm) faucet hole of a sink. Instead, choose a sink without faucet holes then mount the faucet and remote valve through the countertop. Refer to the countertop manufacturer for proper hole drilling.

Observe all local plumbing and building codes. �Shut off the water supplies. �Inspect waste and supply tubing for damage. Replace if necessary. �Before installation, unpack the faucet and inspect for damage. �For new installations, assemble the faucet to the sink before installing the sink. �Kallista reserves the right to make revisions in the design of faucets without notice, as specified in the Price �Book.

INSTALLATION

NOTe:1. Locate the remote valve within 8” (20.3 cm) of the spout. Refer to the countertop manufacturer for proper hole drilling.

1-3/8” (3.5 cm) D. Max

2-1/16” (5.2 cm) D.

8” (20.3 cm) Max

Spout Hole

Valve Hole

Remove the diverter housing. 2. NOTe: DO NOT remove the plug for the optional sidespray.

Diverter Housing

Plug

Press to remove.

Page 3: Kitchen Faucet with Remote Valveresources.kohler.com/interiors/kallista/pdf/1104263_2.pdf · components from this faucet. This faucet contains back-siphonage protection. NOTICe: Due

INSTALLATION INSTRUCTIONS

Kitchen Faucet with Remote Valve

1104263_2_B3 of 7

Questions? Problems? For additional assistance, please contact Kallista’s CustomerService Department at 1-888-4KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.

Apply plumbers putty to underside of escutcheon. 3.

Escutcheon

Insert the faucet through the surface material. 4.

Partially thread screws into the 5. ring.

Slide the fiber and metal washers onto the faucet shank. Thread 6. the ring leaving approximately 1/4” (6 mm) between the ring and the surface material.

Fiber Washer

Metal Washer

Ring

Ring

1/4” (6 mm)

Surface Material

INSTALLATION

Page 4: Kitchen Faucet with Remote Valveresources.kohler.com/interiors/kallista/pdf/1104263_2.pdf · components from this faucet. This faucet contains back-siphonage protection. NOTICe: Due

INSTALLATION INSTRUCTIONS

Kitchen Faucet with Remote Valve

1104263_2_B4 of 7

Questions? Problems? For additional assistance, please contact Kallista’s CustomerService Department at 1-888-4KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.

Turn the ring until the screws are to the front and 7. back. Tighten the screws securely and evenly.

Re-install the diverter housing. 8. NOTe: DO NOT remove the plug for the optional sidespray.

Diverter Housing

Plug

Press to re-install.

INSTALLATION

Page 5: Kitchen Faucet with Remote Valveresources.kohler.com/interiors/kallista/pdf/1104263_2.pdf · components from this faucet. This faucet contains back-siphonage protection. NOTICe: Due

INSTALLATION INSTRUCTIONS

Kitchen Faucet with Remote Valve

1104263_2_B5 of 7

Questions? Problems? For additional assistance, please contact Kallista’s CustomerService Department at 1-888-4KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.

9. Apply plumbers putty to underside of a. remote valve.Insert the remote valve through the b. surface material.

Remote Valve

Position the remote valve with the cold water supply on 10. the left AND the spout connection toward the front of the sink. NOTe: When the lever is pulled toward the front of the sink, the red and blue markings on the escutcheon will be revealed.

Cold Water Supply Tag

Cold

Hot

On

Partially thread screws into 11. the ring.

Slide the washer onto the remote valve shank. Thread the ring 12. leaving approximately 1/4” (6 mm) between the ring and the surface material.

Washer

Ring

Surface Material

1/4” (6 mm)

Ring

INSTALLATION

Page 6: Kitchen Faucet with Remote Valveresources.kohler.com/interiors/kallista/pdf/1104263_2.pdf · components from this faucet. This faucet contains back-siphonage protection. NOTICe: Due

INSTALLATION INSTRUCTIONS

Kitchen Faucet with Remote Valve

1104263_2_B6 of 7

Questions? Problems? For additional assistance, please contact Kallista’s CustomerService Department at 1-888-4KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.

Turn the ring until the screws are to 13. the front and back. Tighten the screws securely and evenly.

Connect the hose from the remote valve to the diverter 14. housing.

Diverter Housing (From Spout)

From Remote Valve

Press to insert hose.

Connect and tighten the supply hoses. 15. NOTe: If the sink installation requires that you coil the supply hoses, maintain a 3” (7.6 cm) diameter minimum inside coil.

Cold

Hot

3" (7.6 cm) D. Minimum

Check for leaks. 16.

INSTALLATION

Page 7: Kitchen Faucet with Remote Valveresources.kohler.com/interiors/kallista/pdf/1104263_2.pdf · components from this faucet. This faucet contains back-siphonage protection. NOTICe: Due

INSTALLATION INSTRUCTIONS

Kitchen Faucet with Remote Valve

1104263_2_B7 of 7

Questions? Problems? For additional assistance, please contact Kallista’s CustomerService Department at 1-888-4KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.

Remove the aerator. 17.

Key

Flush the lines. 18. Reinstall the aerator. 19. DO NOT overtighten. NOTe: Retain the key for future use.

Key

If using optional sidespray (purchased separately), remove plug from diverter and install sidespray 20. according to manufacturer’s instructions.

Diverter Housing (From Spout)

Plug

Diverter Housing (From Spout)

From Optional Sidespray (Purchased Separately)

Press to release plug.

Press to insert hose.